BD / A : EXCAVATION

Sr. No Item of Code Description of Items

1 Excavation for foundation in…….. Including removing the excavated


materials upto a distance of 50 metres. beyond the building area and
lift upto 1.50 metres,Stacking and spreading as directed including
dewatering unless provided elsewhere. Preparing the bed for the
foundation and necessary backfilling, ramming, watering complete
excluding shorting and strutting.(PWDSR.2013/14, P.N.5,I.N.1)

Bd/A-1 P- a) earth, soil of all types, sand, gravel and soft murum
259
Bd/A-2 P-259 b) hard murum

Bd/A-3 P-259 c) hard murum with boulders upto 0.100 Cum

2 Excavation for foundation in…….. Including removing the excavated


materials upto a distance of 50 metres beyond the building area,
stacking and spreading as directed including dewatering manually,
preparing the bed for the foundation dewatering manually, preparing
the bed for the foundation and necessary backfilling, ramming,
watering complete excluding shoring and strutting . (Add for every
additional vertical lift of 1.50 metres)..(PWDSR.2012/13, P.N.5,I.N.2)

Bd/ A-1 P-259 a) earth, soil of all types, sand, gravel and soft murum

Bd/A-2 P-259 b) hard murum

Bd/A-3 P-259 c) hard murum with boulders upto 0.100 Cum

3 Bd/A-4 P-259 Excavation for foundation in soft rock and old cement or lime
masonry foundation including removing the excavated materials upto
a distance of 50 metres beyond the building area and lift upto 1.50
metres, stacking as directed including dewatering unless provided
elsewhere, preparing the bed for the foundation and necessary
backfilling with available earth, murum, ramming, watering complete
excluding shorting and strutting. .(PWDSR.2013/14, P.N.5,I.N.3)

PAGE NO : 5
4 Bd/A-4 P-259 Excavation for foundation in soft rock and old cement or lime
masonry foundation including removing the excavated materials upto
a distance of 50 meters beyond the building area and stacking as
directed including dewatering unless provided elsewhere, preparing
the bed for the foundation and necessary backfilling with available
earth, murum, ramming, watering complete excluding shorting and
strutting. (Add for every additional vertical lift of 1.50 metres).
(PWDSR.2013/14, P.N.6,I.N.4)
5 Bd/A-5 P-259 Excavation for foundation in hard rock by blasting including trimming
and levelling the bed by chiselling where necessary and removing the
excavated meterials and stacking it in measurable heaps within a
distance of 50 metres from the building area and lift upto 1.50 metres
including dewatering unless provided elsewhere, backfilling with
available earth, murum, ramming and watering complete.
(PWDSR.2012/13, P.N.6,I.N.5)

6 Bd/A-6 P-260 Excavation for foundation in hard rock by chiselling, wedging, line
drilling etc. including trimming and levelling the bed.removing the
excavated meterial upto a distance of 50 metres beyond the building
area and lift upto 1.50 metres, stacking as directed including
dewatering manually. backfilling with available earth, murum,
ramming and watering complete.(PWDSR.2013/14, P.N.6,I.N.6)

7 Bd/A-6 P-260 Excavation for foundation in hard rock by control blasting by taking
extra precaution and covering the steel plate over the drilled holes etc.
complete including trimming and levelling the bed, removing the
excavated material upto a distance of 50 metres beyond the building
area and lift upto 1.50 metres, stacking as directed including
dewatering manually, backfilling with available earth, murum,
ramming and watering complete.(PWDSR.2013/14, P.N.6,I.N.7)

8 Dewatering the excavated trenches and pools of water in the building


area by using…… and other devices, including disposing off water to
a safe distance as directed. (PWDSR.2013/14, P.N.6,I.N.8)
Bd/A-9 P-261 a) 3 H.P. pump
Bd/A-9 P-261 b) 5 to 9 H.P. pump
Bd/A-9 P-261 c) 10 to 19 H.P. pump
PAGE NO : 6
9 Filling in plinth and floors……. In 15 cm to 20 cm layers including
watering and compaction complete.(PWDSR.2013/14, P.N.7,I.N.9)

Bd/A-10 P-262 a) with approved excavated materials

Bd/A-11 P-263 b) with contractor's murum

10 Bd/A-12 P- Providing dry trap/ rubble stone soling 15 cm to 20 cm thick including


264 hand packing and compacting etc. complete..(PWDSR.2013/14,
P.N.7,I.N.10)

Note : Item should not be used for plinth filling and plinth protection.

11 Bd/A-12 P- Spreading and handpacking dry rubble for soling including filling
264 voids by chips, compacting as directed. (Using Govt. stone)..
(PWDSR.2013/14, P.N.7,I.N.11)
Note : Item should not be used for plinth filling and plinth protection.
12 Bd/A-12 P- Providing Soling using 80 mm size trap metal in 15 cm layer including
264 filling voids with sand, ramming, watering etc. complete. .
(PWDSR.2013/14, P.N.7,I.N.12)
PAGE NO : 7
BD-B : PILE FOUNDATION
1 Providing M-30 R.C.C. east in situ bored piles each of load capacity
and as per design and of …… diameter or as directed placed through
all strata except rock excluding provision of reinforcement as per
detailed drawings and design approved by the Engineer-in-charge
including placing concrete by tremie arrangements, compaction of
concrete and withdrawal of shell etc. complete..(PWDSR.2013/14,
P.N.9,I.N.1)

Bd/B-4 P-270 i) 325 mm diameter

ii) 350 mm diameter


iii) 400 mm diameter
iv) 425 mm diameter
v) 475 mm diameter
vi) 475 mm diameter (Using RMC)
vii) 500 mm diameter
viii) 525 mm diameter
ix) 550 mm diameter
x) 600 mm diameter
xi) 600 mm diameter (Using RMC)
xii) 625 mm diameter
xiii) 650 mm diameter
xiv) 650 mm diameter (Using RMC)
xv) 750 mm diameter
xvi) 750 mm diamter (Using RMC)
xvii) 800 mm diameter
xviii) 800 mm diameter (Using RMC)
xix) 825 mm diameter
xx) 900 mm diameter
xxi) 900 mm diameter (Using RMC)
xxii) 975 mm diameter
xxiii) 1000 mm diameter
xxiv) 1050 mm diameter
PAGE NO : 9
2 Bd/B-2 P-269 Chiselling through pile shells in hard strata like boulders, soft and hard
rocks …… including removing and stacking the loose materials etc.
complete and disposing of the unserviceable mareials outside
complete.(PWDSR.2013/14, P.N.10,I.N.2)
1) Upto and inclusive of 550 mm diameter.
2) Beyond 550 mm and upto and inclusive of 750 mm dia.
3) Beyond 750 mm and upto and inclusive of 900 mm dia.
4) Beyond 900 mm and upto and inclusive of 1050 mm dia.
3 Bd/B-8 P-271 Carrying out load test for 1.5 times the proposed safe working load on
the pile in driven position ……. Including construction of test cap, use
of accessories and instruments including providing graphs as per I.S.
code or std. Specification and dismantling the test cap after testing and
cleaning the site complete. (PWDSR.2013/14, P.N.10,I.N.3)

i) upto 400 mm diameter


ii) above 400 mm and upto to 550 mm diameter
iii) above 550 mm and upto 650 mm diameter
iv) above 650 mm and upto 750 mm diameter
v) above 750 mm and upto 825 mm diameter
vi) above 825 mm and upto 900 mm diameter
vii) above 900 mm diameter
PAGE NO : 10
4 Empty boring for……… bored R.C.C. cast in situ piles including
withdrawal of shell, removal of earth to a distance of 50 metres etc.
complete. (PWDSR.2013/14, P.N.11,I.N.4)
Spec: (As directed by Engineer in charge)
i) 325 to 400 mm dia
ii) 425 to 500 mm dia
iii) 525 to 600 mm dia
iv) 625 to 700 mm dia
v) 725 to 1050 mm dia
5 Chipping and dressing of the R.C.C. piles upto 0.60 meter including
cleaning reinforecement and removal of dismantled materials upto a
distance of 50 meter beyond the building area etc. for providing pile
caps.(PWDSR.2013/14, P.N.11,I.N.5)
Spec: (As directed by Engineer in charge)
6 Providing bentonite slurry process for various diameter of piles vide
Item Nos 1 (I to xviii) above. (PWDSR.2013/14, P.N.11,I.N.6)
Spec: (As directed by Engineer in charge)
PAGE NO : 11
BD-E : PLAIN CEMENT CONCRETE
1 Providing and laying in situ plain cement concrete ……… of trap
metal for foundation and bedding including bailing out water
manually, formwork,compacting and curing.(PWDSR.2013/14,
P.N.13,I.N.1)
Bd/E-1 P-287 a) 1:5:10
Bd/E-1 P-287 b) 1:4:8
Bd/E-1 P-287 c) M-10
Bd/E-1 P-287 d) M-15
Bd/E-1 P-287 e) M-20
Bd/E-1 P-287 f) M-25
2 Providing and casting in situ plain cement concrete M-15 of trap metal
……. Including centering formwork, compacting, finishing the
exposed faces with suffcient minimum thickness of 1:3 cement plaster
to give a smooth and even surface or rougening the exposed faces if
special finish is to be provided and curing. (PWDSR.2013/14,
P.N.13,I.N.2)

Bd/E-2 P-288 a) for steps


Bd/E-2 P-288 b) for coping to plinth or parapet rounded or chamfered as per drawing

c) for coping to plinth or parapet rounded or chamfered as per


drawings (Using RMC)
3 Bd/E-2 P-288 Providing and casting in situ plain cement concrete M-15 of trap metal
for bed blocks, foundation blocks and such other items including
bailing out water manually, formwork, compacting, finishing the
exposed faces with sufficient minimum thickness of 1:3 cement plaster
to give a smooth and even surfaces or roughrning the exposed faces if
special finish is to be provided and curing.(PWDSR.2013/14,
P.N.13,I.N.3)

PAGE NO : 13
4 Bd/E-2 P-288 Providing and casting in situ plain cement concrete M-15 of trap metal
for plain or moulded sills, cornice jambs block in course or architraves
of requried size and shape, including centering formwork, compacting,
finishing the exposed faces with sufficient minimum thickness of 1:3
cement plaster top give a smooth and even surface or roughening the
exposed faces if. special finish is to be provided and curing.
(PWDSR.2013/14, P.N.14,I.N.4)

5 Chipping the R.C.C surface and cleaning the rusted reinforcement and
exposed surface by wire brush mechanical device or any other
established method and applying rust removing solution of approved
make and quality with cotton waste swab to reinforcement and
allowing to dry the same for 24 hours, brushing of loose particle and
applying 1st coat of rust preventive coating of polymer and cement
slurry in 1:1:5 proportion with soft brush without adding water
including applying another coat of rust preventing after 4 hours
allowing Air Curing for 48 hours etc. including scaffolding etc.
complete. (PWDSR.2013/14, P.N.14,I.N.5)

Spec: (As directed by Engineer in charge)


6 Providing and applying a priming cum bonding coat of polymer of
approved make and quality as approved by Engineer-in-charge and
cement slurry in 1:1 proportionate by weight to concrete area by brush
or any other established method etc.complete.(PWDSR.2013/14,
P.N.14,I.N.6)

Spec: (As directed by Engineer in charge)


7 Providing and applying 15mm thick polymer mortar to load carrying
R.C.C members in two layers in proportion of 1:5:15 by weight of
polymer of approved make and quality, cement and Quartz sand with
required water cement ratio for desird consistency and applying and
finishing by floating, curing after initial setting time etc. as per
manufacturers specification etc. complete. (With prior approval of
SEMC).(PWDSR.2013/14, P.N.14,I.N.7)

Spec: (As directed by Engineer in charge)


PAGE NO : 14
8 Providing and applying 30 mm thick polymer mortar to load carrying
R.C.C member in two layers in proportion of 1:5:15 by weight of
Polymer of approved make and quality, cement and Quartz sand with
required water cement ratio for desired consistency and applying and
finishing by floating, after curing initial setting time applying bonding
coat for 2nd coat etc. as per manufactures specification etc. complete.
(With prior approval by SEMC)(PWDSR.2013/14, P.N.15,I.N.8)

9 Providing and applying 15 mm thick polymer mortar to load carrying


R.C.C member in two layers in proportion of 1:5:15 by weight
Polymer of approved quality and make, cement and washed river sand
with required W.C ratio for desired consistency and applying and
finishing by floating, curing after initial setting time etc. a per
manufactures specification etc. complete.(PWDSR.2013/14,
P.N.15,I.N.9)

Spec: (As directed by Engineer in charge)


10 Providing and applying 30 mm thick polymer mortar to load carrying
R.C.C member in two layers in proportion of 1:5:15 by weight of
Polymer of approved quality and make, cement and washed river sand
with required water cement ratio for desired consistency and applying
and finishing by floating, curing after curing initial setting time etc. as
per manufactures specification etc. complete. (PWDSR.2013/14,
P.N.15,I.N.10)

Spec: (As directed by Engineer in charge)


11 Providing and applying 20 mm thick polymer modified concrete mix
in 1:1:2 proportion of cement, aggregate and river sand with 0.6 Kg.
Polymer of approved quality and make per 10 Kg. Of cement,
applying and floating in two layer with water cement ratio for desired
consistency, curing etc. as per manufactures specification
etc.complete.(PWDSR.2013/14, P.N.15,I.N.11)

Spec: (As directed by Engineer in charge)


12 Providing and applying 40 mm thick polymer modified concrete mix
in 1:1:2 proportion of cement, aggregate and river sand with 0.6 Kg.
Of polymer of approved make and quality per 10 Kg. Of cement
applying and floating in two layer with water cement ratio for desired
consisstency, curing applying bonding coat for 2nd layer etc. as per
manufactures specification etc. complete.(PWDSR.2013/14,
P.N.15,I.N.12)

Spec: (As directed by Engineer in charge)


PAGE NO :- 15
13 Providing and applying 50 mm thick polymer modified concrete mix
in 1:1:2 proportion of cement, aggregate and river sand with 0.6 Kg.of
polymer of approved make and quality per 10 Kg. Of cement,
applying and floating in layers with water cement ratio for desired
consistency, curing including applying bonding coat for 2nd layer etc.
as per manufactures specification etc. complete. (With prior approval
of SEMC)

Spec: (As directed by Engineer in charge)


14 Providing and applying 60 mm thick polymer modified concrete mix
in 1:1:2 proportion of cement, aggregate and river sand with 0.6 Kg.
Of Polymer of approved make and quality per 10 Kg. Of cement,
applying and floating in layers with water cement ratio for desired
consistency, curing including applying bonding coat for 2nd layer etc.
as per manufactures specification etc. complete. (With prior approval
of SEMC)(PWDSR.2013/14, P.N.15 I.N.14)

Spec: (As directed by Engineer in charge)


PAGE NO : 16
BD-F : REINFORCED CEMENT CONCRETE
Note : All R.C.C. items of M-30/35/40 are based on assumption of cement content of 400/425/
1 However
Providingactual cementinconsumptions
and Casting shall be ……
situ cement concrete as perofMix
trapdesign
metal confirming
for conditions
ensured that cement content of Mix design shall be economical
R.C.C. pile caps as per detailed designs and drawings including and within limit as presc
Table 5 out
bailing at page-20 and Clause
water manually, 8.2. 4.2).
centering, This aspect
formwork, may be noted and necessary conditi
compacting,
specification/
finishing tender (Excluding
and curing paper. steel reinforcement) The rate is
inclusive of rectification of honeycombed patches if observed by
patching the honeycombed surface by polymer mortar using quartz
sand 1:3 and injecting plymer grout with 2 kg. per square centimeter
pressure by hand operated grout pump after 28 days of casting.
(PWDSR.2013/14, P.N.17,I.N.1)

Bd/F-1 P-297 a) M-20

Bd/F-1 P-297 b) M-25

Bd/F-1 P-297 c) M-30

Bd/F-1 P-297 d) M-35


Bd/F-1 P-297 e) M-40

PAGE NO :-17
2 Providing and casting in situ cement concrete …….. Of trap metal for
R.C.C. work in foundation like raft, strip, grillage foundation and
footing of R.C.C. columns and steel stanchions including bailing out
water manually, centering, formwork, compacting, finishing and
curing.The rate is inclusive of rectification of honeycombed patches if
observed by patching the honeycombed surface by polymer mortar
using quartz sand 1:3 and injecting polymer grout with 2 kg. per
square centimeter pressure by hand operated grout pump after 28 days
of casting. (Excluding mild steel reinforcement and structural steel).
(PWDSR.2013/14, P.N.18,I.N.2)

Bd/F-3 P-298 a) M-20


Bd/F-3 P-298 b) M-25
Bd/F-3 P-298 c) M-30
Bd/F-3 P-298 d) M-35
Bd/F-3 P-298 e) M-40
.. f) M-30 (Using RMC)
3 Bd/F-5 P-300 Providing and casting in situ cement concrete…… of trap metal for
(except propor- R.C.C. columns as per detailed designs and drawings or as directed
tion) including centering, formwork, compacting, finishing the formed
surfaces with cement mortar 1:3 of sufficient minimum thickness to
give a smooth and even surface or roughening the surface if special
finish is to be provided and curing. The rate is inclusive of
rectification of honeycombed patches if observed by patching the
honeycombed surface by plymer mortar using quartz sand 1;3 and
injecting poylmer grout with 2 kg. per square centimeter pressure by
hand operated grout pump after 28 days of casting. (Excluding steel
reinforcement). (PWDSR.2013/14, P.N.18,I.N.3)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO: 18
4 Bd/F-6 P-300 Providing and casting in situ cement concrete …….. Of trap metal for
(except propor- R.C.C. Beams and lintels as per detailed designs and drawings or as
tion) directed including centering, formwork, compacting, finishing the
formed surface with cement mortar 1:3 of sufficient minimum
thickness to give a smooth and even surface or roughening the surface
if special finish is to be provided and curing. The rate is inclusive of
rectification of honeycombed patches if observed by patching the
honeycombed surface by polymer mortar using quartz sand 1:3 and
injecting polymer grout with 2 kg. per square centimeter pressure by
hand operated grout pump after 28 days of casting.
(Excluding steel reinforcement).(PWDSR.2013/14,
P.N.19,I.N.4)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
5 Bd/F-8 (a) Providing and casting in situ cement concrete ……… of trap metal for
P-302 R.C.C. slabs and landings upto and inclusive of 10 cm thickness as per
(except propor- detailed drawings and designs including centering, formwork,
tion) compacting, finishing the formed surfaces with cement mortar 1:3 of
sufficient minimum thickness to give a smooth and even surface or
roughening the surface if special finish is to be provided and curing.
The rate is inclusive of rectification of honeycombed patches if
observed by patching the honeycombed surface by poylmer mortar
using quartz sand 1:3 and injecting polymer grout with 2 kg. per
square centimeter pressure by hand operated grout pump after 28 days
of casting (Excluding steel reinforecement).(PWDSR.2013/14,
P.N.19,I.N.5)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO : 19
6 Bd/F-8 (b) Providing and casting in situ cement concrete…….. Of trap metal for
P-302 R.C.C. slab and landings above 10 cm thickness aand upto and
(except propor- inclusive of 12.5 cm thickness as per detailed drawings and designs
tion) including centering, formwork, compacting, finishing the formed
surfaces with cement mortar 1:3 of sufficient minimum thickness to
give a smooth and even surface or roughening the surface if special
finish is to be provided and curing. The rate is inclusive of
rectification of honeycombed patches if observed by patching the
honeycombed surface by polymer mortar using quartz sand 1:3 and
injecting polymer grout with 2 kg. per square centimeter pressure by
hand operated grout pump after 28 days of casting. (Excluding steel
reinforcement).(PWDSR.2013/14, P.N.20,I.N.6)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
7 Bd/F-8 (c) Providing and casting in situ cement concrete …….. of trap metal for
P-302 R.C.C. slabs and landings above 12.5 cm thickness and upto and
(except propor- inclusive of 15 cm thickness as per detailed drawings and designs
tion) including centering, formwork, compacting, finishing the formed
surface with cement mortar 1:3 of sufficient minimum thickness to
give a smooth and even surface or roughening the surface if special
finish is to be provided and curing. The rate is inclusive of
rectification of honeycombed patches if observed by patching the
honeycombed surface by polymer mortar using quartz sand 1:3 and
injecting polymer grout with 2 kg. per square centimeter pressure by
hand operated grout pump after 28 days of casting (Excluding steel
reinforcement).(PWDSR.2013/14, P.N.20,I.N.7)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO : 20
8 Bd/F-8 (d) Providing and casting in situ cement concrete ……… of trap metal for
P-302 R.C.C. slabs and landings above 15 cm thickness as per detailed
(except propor- drawings and designs including centering, formwork, compacting,
tion) finishing the formed surface with cement mortar 1:3 of sufficient
minimum thickness to give a smooth and even surface or roughening
the surface if special finish is to be provided and curing.The rate is
inclusive of rectification of honeycombed patches if observed by
patching the honeycombed surface by polymer mortar using quartz
sand 1:3 and injecting polymer grout with 2 kg. per square centimeter
pressure by hand operated grout pump after 28 days of casting.
(Excluding steel reinforcement).(PWDSR.2013/14, P.N.21,I.N.8)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
9 Bd/F-9 P- Providing and casting in situ cement concrete ……. of trap metal for
303 (except R.C.C. chajja as per detailed drawings and designs including
propor-tion) centering,n formwork, compacting, finishing the formed surface with
cement mortar 1:3 of sufficient minimum thickness to give a smooth
special finish is to be provided and casting.The rate is inclusive of
rectification of honeycombed patches if observed by patching the
honeycombed surface by polymer mortar using quartz sand 1:3 and
injecting polymer grout with 2 kg. per square centimeter pressure by
hand operated grout pump after 28 days of casting. (Excluding steel
reinforcement).(PWDSR.2013/14, P.N.21,I.N.9)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO : 21
10 Bd/F-10 Providing and casting in situ cement concrete …….. of trap metal for
P-304 (except R.C.C. canopy as per detailed drawings and designs including
propor-tion) centering, formwork, compacting all special finishes and ornamental
work and curing.The rate is inclusive of rectification of honeycombed
patches if observed by patching the honeycombed surface by polymer
mortar using quartz sand 1:3 and injecting polymer grout with 2 kg.
per square centimeter pressure by hand operated grout pump after 28
days of casting. (Excluding steel reinforcement).(PWDSR.2013/14,
P.N.22,I.N.10)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
11 Bd/F-10 Providing and casting in situ cement concrete ……. of trap metal for
P-304 (except R.C.C. pardi of 75 mm thick and drops wherever required in patches
propor-tion) as per detailed drawing and design by using material, equipments such
as mixer, vibratores, lift machine etc. with 200ml. plastisizer for better
workability of concrete including all centering formwork compacting,
finishing the surface of roughing the surface of special finish to be
provided and curing for 14 days etc. complete. This item shall be
covering 10 years guarantee bond on 10/- Rs. stamp paper this 10
years guarantee covers attending the damage and leakage complaints
when ever occurs. Also rate is inclusive of periodical inspection twice
a year of same (G +10 storied) building. This includes co-ordination
while execution of work with residents making working platform on
each floor for smooth movement of labour and materials etc.
complete. The rate is inclusive of rectification of honeycombed
patches if observed by patching the honeycombed surface by polymer
mortar using quartz sand 1:3 and injecting polymer grout with 2 kg.
per square centimeter pressure by hand operated grout pump after 28
days of casting. (Excluding steel reinforcement).(PWDSR.2013/14,
P.N.22,I.N.11)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO: 22
12 Bd/F-13 Providing and casting in situ cement concrete …….. of trap metal for
P-305 (except R.C.C. waist slabs, steps and parapet as per detailed drawings for
propor-tion) staircase including centering, formwork, compacting, finishing the
formed surface with cement mortar 1:3 of sufficient minimum
thickness to give a smooth snd even surface if special finish is to be
provided and curing.The rate is inclusive of rectification of
honeycombed patches if observed by patching the honeycombed
surface by polymer mortar using quartz sand 1:3 and injecting
polymer grout with 2 kg. per square centimeter pressure by hand
operated grout pump after 28 days of casting. (Excluding steel
reinforcement).(PWDSR.2013/14, P.N.23,I.N.12)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
13 Bd/F-16 Providing and casting in situ cement concrete ……. Of trap metal for
P-306 (except R.C.C. fins 65 mm thick in position as shown in drawings or as
propor-tion) directed by Engineer including centering, formwork, compacting,
finishing the formed surface with cement mirtar 1:3 of sufficient
minimum thickness to give a smooth and even surface or roughening
the surface if special finish is to be provided and curing The rate is
inclusive of rectification of honeycombed patches if observed by
patching the honeycombed surface by polymer mortar using quartz
sand 1:3 and injecting polymer grout with 2 kg. per square centimeter
pressure by hand operated grout pump after 28 days of casting.
(Excluding steel reinforcement).(PWDSR.2013/14, P.N.23,I.N.12)

a) M-20
b) M-25
c) M-30
d) M-35
e) M-40
f) M-30 (Using RMC)
PAGE NO : 23
14 Providing and fixing in position …… of various diameters for R.C.C.
pile caps, footings, foundation, slabs, beams, columns, canopies,
staircase, newels, chajjas, lintels, pardies, coping, fins, arches, etc, as
per detailed designs, drawings and schedules including cutting,
bending, hooking the bars, binding with wires or tack welding and
supporting as requried complete.(PWDSR.2013/14, P.N.24,I.N.14)

Bd/F-17 P- a) Mild steel bar reinforcement / Tor steel bar reinforecement


306
Bd/F-17 b) T.M.T. bar reinforcement
P-306
15 Providing and applying Anti corrosive treatment to Mild steel, Tor
steel reinforcement bars as per cement polymer composite coating
(C.P.C.C.) method developed by C.E.C.R.I. including cleaning the bar
by means of any established mechanical or manual method for
removing rust and deleterious material, applying rapid setting primer
and cement polymer sealing coat of approved and licensed by CECRI
including redoing the process if damage occurs during handling,
stacking etc. complete. (With prior approval of SEMC).
(PWDSR.2013/14, P.N.24,I.N.15)

Spec: (As directed by Engineer in charge)


16 Bd/F-20 P- Providing and fixing in position after hoisting precast 1:2 cement
307 mortar reinforced jali 50 mm thick of approved design in cement
mortar 1:3 and curing complete. (including 6 mm dia. Mild steel bar
reinforcement).(PWDSR.2013/14, P.N.24,I.N.16)
PAGE NO : 24
17 Providing and casting in situ R.C.C. reservoir at terrace level as per
approved detailed designs and drawings including steel reinforcement,
bottom slab, side walls, inner compartment wall, haunches and inner
beam if any, in cement concrete M-20 and cover slab in cement
concrete M-15 including centering, formwork, using waterproofing
compound at the rate of 1 kg per bag of cement, cast iron round
manhole cover of 45 cm diameter or larger diameter if specified for
each compartment with locking arrangement, galvanised iron inlet and
outlet connection pipes of requried diameter, scour pipes with plug,
overflow pipes conforming to M.C.G.M. requirement, finishing the
inside surface in cement mortar 1:3 plaster with waterproofing
compound at rate of 1 kg per bag of cement and neat cement finish
and sand faced plaster in cement mortar 1:4 from outside, watering
and curing etc. excluding provision of ball cock for consolidated
capacity ....... excluding free board of 15 cm at top and 5 cm dead
storage height in between bottom slab and invert of outlet pipe. (Rate
for Block Estimate purpose only).(PWDSR.2013/14, P.N.25,I.N.17)

Spec: (As directed by Engineer in charge)


a) upto 5000 litres
b) above 5000 Litres
18 Dismantling R.C.C. work including breaking concrete by chiseling,
wedging etc. cuttihg the reinforcement, stacking the serviceable
materials and stacking the debris upto a distance of 50 meters or
spreading etc. complete.(PWDSR.2013/14, P.N.25,I.N.18)
Spec: (As directed by Engineer in charge)
19 Dismantling plain cement concrete work including breaking concrete
by chiseling, wedging etc., stacking the serviceable materials and
stacking the debris upto a distance of 50 metres or spreading etc.
complete.(PWDSR.2013/14, P.N.25,I.N.19)
Spec: (As directed by Engineer in charge)
PAGE NO : 25
New Items
Note : The follwing all new items may be used on experimental basis for one
year only.
20 Providing and laying Engineered Concrete coating system of Monopol
456 for Anti-corrosive and Antincarbonation application in Moderate
to aggressive Environments for.....(PWDSR.2013/14, P.N.26,I.N.20)

Spec: (As directed by Engineer in charge)


a) slab
b) Beam/Column
21 Providing high performance Anti carbonation protective coating for repa
Spec: (As directed by Engineer in charge)
PAGE NO :- 26
22 Providing Bipolar Concrete Penetrating Corrosion Inhibiting Admixture
Spec: (As directed by Engineer in charge)
23 Providing encasement to columns/beams/pardi etc. With free flow high s
Spec: (As directed by Engineer in charge)
PAGE NO:- 27
24 Providing and casting in situ cement concrete M-35 of trap metal for
Spec: (As directed by Engineer in charge)
25 Providing and casting in situ cement concrete M-30 of trap metal for
Spec: (As directed by Engineer in charge)
26 Providing and applying one coat of single component Hybrid Acrylic Sil
Spec: (As directed by Engineer in charge)
PAGE NO:- 28
BD-G : BRICK WORK
1 Bd/G-1 P-313 Providing Second class Burnt Brick masonry with conventional/ I.S.
type bricks in cement mortar 1:6 in foundations and plinth of inner
walls / in plinth of external walls including bailing out water manually,
striking joints on unexposed faces, racking out joints on exposed
faces and watering etc. complete. (PWDSR.2013/14, P.N.29,I.N.1)

2 Bd/G-3 P-314 Providing Second class Burnt Brick masonry with conventional/ I.S.
type bricks in cement mortar 1:6 in plinth as backing in composite
masonry including striking joints, watering and scaffolding etc.
complete.(PWDSR.2013/14, P.N.29,I.N.2)
3 Bd/G-5 P-315 Providing Second class Burnt Brick masonry with conventional /I.S.
type bricks in cement mortar 1:6 in superstructure including striking
joints, racking out joints, watering and scaffolding etc. complete.
(PWDSR.2013/14, P.N.29,I.N.3)
4 Bd/G-5 P-315 Providing Second class Burnt Brick masonary with conventional/ I.S.
type bricks in cement mortar 1:8 in superstructure including striking
joints, racking out Joints, watering and scaffolding etc. complete.
(PWDSR.2013/14, P.N.29,I.N.4)
5 Bd/G-6 P-316 Providing Second class Burnt Brick masonry with conventional / I.S.
type bricks in cement mortar 1:6 in superstructure as backing in
composite masonry including scaffolding, racking out joints and
watering etc. complete.(PWDSR.2013/14, P.N.29,I.N.5)
6 Bd/G-7 P-316 Providing Second class Burnt Brick masonry with conventional/ I.S.
type bricks in cement mortar 1:4 in half brick thick wall including
mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2
hoop iron strips 25 mm *1.6 mm at every third course properly bent
and bonded at ends, scaffolding, racking out joints and watering etc.
complete.(PWDSR.2013/14, P.N.29,I.N.6)
PAGE NO : 29
7 Providing and constructing ……. Steam cured cellular (acrated)
concrete block masonry with steam cured cellular concrete block
confirming B.I.S. 6041/6042/6441/3809 having density not less than
640 kg. per cum. In cement mortar 1:6 including adequate plastisizer
for non bearing portion including racking out joints scaffolding &
curing etc. complete.(PWDSR.2013/14, P.N.30,I.N.7)

Spec: (As directed by Engineer in charge)


a) 100 mm thick
b) 150 mm thick
c) 200 mm thick
8 Pulling down burnt brick masonry (in cement mortar) with plaster
including sorting out serviceable bricks and stacking the same and
debris separtely upto a distance of 50 metres or spreading the debris
etc. complete.(PWDSR.2013/14, P.N.30,I.N.8)
Spec: (As directed by Engineer in charge)
9 Cutting holes in burnt brick masonry walls to receive ends of girders
of any size including scaffolding etc. complete. (PWDSR.2013/14,
P.N.30,I.N.9)
Spec: (As directed by Engineer in charge)
New Items
Note : The following all new items may be used on experimental basis for one year only.
10 Providing autoclaved cellular concrete block masonary confirming to IS
Spec: (As directed by Engineer in charge)
11 Providing autoclaved cellular concrete block masonary confirming to
IS 2185 (Part-3) of size ........ In cement mortar 1:4 in superstructure
including bailing out water manually, striking joints on unexposed
faces, racking out joints on exposed faces and watering etc. complete.
(PWDSR.2013/14, P.N.30,I.N.11)

Spec: (As directed by Engineer in charge)


a) 75x240x650 mm
b) 100x240x650 mm
c) 150x240x350 mm
PAGE NO:- 30
12 Providing Green Build Product (GBP) Build Fast Plus masonry
ecofriendly wet mix/Blocks laying Adhesive is a pre-polymerized, wet
mix jointing adhesive which is suitable for Building masonry wall
with all kind of blocks with thickness of thin layer of 2mm to 4mm
between masonry units. There is no need to pre-wet the Blocks nor to
post cure the wall with water. Confirming to IS 2185 of size ...... in
superstructure including striking joints, racking out joints faces and
scaffolding etc. complete.

Spec: (As directed by Engineer in charge)


a) 100 x 240 x 650 mm
b) 200 x 240 650 mm
PAGE NO : 31
BD-H : STONE MASONRY
1 Bd/H-1 P-329 Providing uncoursed rubble masonry of trap stones in cement mortar
1:6 in foundation and plinth of inner wall including bailing out water
manually, striking joints on unexposed faces and pointing with cement
mortar 1:3 on outside exposed faces and watering complete.
(PWDSR.2013/14, P.N.33,I.N.1)

2 Bd/H-2 P-329 Providing uncoursed rubble masonry of trap stones in cement mortar
1:5 in basement including bailing out water manually, striking joints
on unexposed faces and pointing with cement mortar 1:3 on outside
exposed faces and watering and scaffolding etc. complete.
(PWDSR.2013/14, P.N.33,I.N.2)

3 Bd/H-4 P-331 Providing uncoursed rubble masonry of trap stones in cement mortar
1:6 in superstructure including striking joints and pointing with
cement mortar 1:3 on outside exposed faces and watering and
scaffolding etc. complete.(PWDSR.2013/14, P.N.33,I.N.3)
4 Bd/H-15 P-334 Providing coursed rubble 2nd sort masonry using all stones of full
height in each course of trap stones in cement mortar 1:6 in external
walls of foundation and plinth including dewatering, striking joints
inside and pointing with cement mortar 1:3 on the outside and
watering.(PWDSR.2013/14, P.N.33,I.N.4)

5 Bd/H-16 P-334 Providing coursed rubble 2nd sort masonry using all stones of full
height in each course of trap stones in cement mortar 1:6 in
superstructure including racking out joints on the inside face and
pointing with cement mortar 1:3 on the outside face including
necessary scaffolding, watering etc. complete. (PWDSR.2013/14,
P.N.33,I.N.5)

6 Pulling down stone masonry in cement mortar with plaster/ pointing


without dust nuisance including sorting out the stone chips and debris
separetely and stacking upto distance of 50 meters or spreading the
debris etc. complete.(PWDSR.2013/14, P.N.33,I.N.6)
Spec: (As directed by Engineer in charge)
PAGE NO : 33
7 Cutting holes of any size in stone masonry walls to receive ends of
girders of any size and making good damages done including
scaffolding etc. complete.(PWDSR.2013/14, P.N.34,I.N.7)
Spec: (As directed by Engineer in charge)
PAGE NO : 34
BD-J : WATER PROOFING
1 Bd/J-2 P-355 Providing and laying damp-proof course 40 mm thick 1:2:4 cement
concrete layer and bitumen 30/40 grade using cement with water
proofing compound of approved make and manufactures etc.
complete.(PWDSR.2013/14, P.N.35,I.N.1)
2 Bd/J-2 P-355 Providing and laying damp-proof course 60 mm thick of Shahabad
stone 25 mm to 30 mm thick and bitumen grade 85/25 using cement
mortar 1:3 with water proofing compound of approved make and
manufacture etc. complete. (PWDSR.2013/14, P.N.35,I.N.2)
3 Finishing the terrace slab integrally with cement mortar 1:3 proportion
with 20 mm thick layer including curing, finishing using water
proofing compound at the rate of 1 kg./bag of cement, cleaning the
surface etc. complete.(PWDSR.2013/14, P.N.35,I.N.3)

Spec: (As directed by Engineer in charge)


4 Providing and laying waterproofing treatment of 112 mm average
thickness consisting of 12 mm thick layer in cement Mortar 1:3 with
water proofing compound and jute fiber at the rate of 1 kg per bag of
cement as base, constructing and laying brick bat coba in cement
mortar 1:5 with waterproofing compound at the rate of 1 kg per bag of
cement and having average thickness of 80 mm and finishing with 20
mm thick cement plaster layer in cement mortar 1:3 with water
proofing compound at the rate of 1 kg per cement bag, including all
lead, lifts and laid to proper slope to drain off water entirely including
watta, Bell head or champheted portion at the junction of parapet and
work upto a height of 300 mm or as directed and including finishing
the top layer of water proofing treatment with false marking of 30 cm
* 30 cm or as directed, curing and covering the whole treatment with
ten years' guarantee , on requisite stamp paper etc. complete.
(PWDSR.2013/14, P.N.35,I.N.4)

Spec: (As directed by Engineer in charge)


PAGE NO : 35
5 Providing leak proof treatment by injection prouting method to
existing floor without removing tiles of W.C./ Bath with water
proofing compound and cement solutions (fine sand, cement etc.)
making holes, refilling and making them water tight including making
good the damages, cleaning etc. complete. (PWDSR.2013/14,
P.N.36,I.N.5)

Spec: (As directed by Engineer in charge)


6 Providing waterproof plaster in W.C. and bath 20 mm thick for dado in
cement mortar 1:3 with neat finishing, floating using waterproofing
compound at the rate of 1 kg. per bag of cement of approved make and
manufacturer and curing etc. complete. (PWDSR.2013/14,
P.N.36,I.N.6)

Spec: (As directed by Engineer in charge)


7 Providing waterproofing in W.C. and bath including brick bat coba in
all positions consisting of specialised materials as per manufacturer's
specifications and covering ten years' guarantee on requisite stamp
paper years' guarantee on requisite stamp paper including all leads,
lifts and curing etc. complete. (PWDSR.2013/14, P.N.36,I.N.7)

Spec: (As directed by Engineer in charge)


8 Bd/L-5 P-368 Providing waterproof bedding 25 mm thick for flooring of bath and
W.C. in cement mortar 1:3 using 1 kg of waterproofing compound of
approved make and manufacturer per bag of cement including
leveling, curing etc. complete. (PWDSR.2013/14, P.N.36,I.N.8)
Spec: (As directed by Engineer in charge)
PAGE NO : 36
9 Providing water proofing treatment as per IS : 1346-1966 to generally
inaccessible sloping R.C.C. Terrace slab with bitumen felts in all
positions in five course, consisting of applying cold bitumen primer
coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of
14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type
III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap
commencing at lowest level and again applying hot bitumen course at
the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at
the rate of 0.06 Cum. per 10 Sqm. including all lifts, leads and
scaffolding whenever necessary complete as directed with four years'
guarantee on requisite stamp paper etc. complete. (PWDSR.2013/14,
P.N.37,I.N.9)

Spec: (As directed by Engineer in charge)


10 Removing existing water proofing treatment such as I.P.S./Brick bat
coba etc. from terrace/toilet block without damage to structure,
levelling and cleaning the surface for providing new specialised water
proofing treatment complete. (PWDSR.2013/14, P.N.37,I.N.10)
Spec: (As directed by Engineer in charge)
11 Lowering down the debris obtained from breaking and removing the
cement plaster / burnt brick masonary of the first floor by any means
without causing dust nuisance and damage to structure, stacking the
same as and where directed including cleaning the site complete.(Rate
for loose material).(PWDSR.2013/14, P.N.37,I.N.11)

Spec: (As directed by Engineer in charge)


12 Removing existing water proofing treatment such as tarfelt etc.
without causing any damage to structure from terrace/ roof including
cleaning, levelling the surface, lowering down debris/refusal without
causing dust nuisance and stacking the debris upto a distance of 50
metres etc. complete. (PWDSR.2013/14, P.N.37,I.N.12)

Spec: (As directed by Engineer in charge)


PAGE NO : 37
13 Providing and laying damp-proof course 40 mm thick 1:1,5:3 cement
concrete layer and bitumen 30/40grade@ 2kg/sqm on priming coat
using cement with water proofing compound of approved make and
manufactures etc. complete.(PWDSR.2013/14, P.N.38,I.N.13)
Spec: (As directed by Engineer in charge)
14 Providing and laying waterproofing treatment of 112 mm average
thickness consisting of 12 mm thick layer in cement mortar 1:3 with
water proofing compound at the rate of 1 kg per bag of cement as base
, constructing and laying brick bat coba in cement mortar 1:5 with
waterproofing compound at the rate of 1 kg per bag of cement and
having average thickness of 80 mm and finishing with 20 mm thick
cement plaster layer in cement mortar 1:4, water proofing compound
at the rate of 1 kg per cement bag, laying in requried position flooring
of broken china mosaic (broken pieces of china chips) of approved
colour amd pattern including neat cement float, giving proper slopes,
compaction, curing, finishing etc. including all lead, lifts and laid to
proper slope to drain off water entirely including watta, Bell head or
Champhered portion at the junction of parapet and work upto a height
of 300 mm or as dorected and covering the whole treatment with ten
years' guarantee, on requisite stamp paper etc. complete.
(PWDSR.2013/14, P.N.38,I.N.14)

Spec: (As directed by Engineer in charge)


15 Providing waterproof plaster in W.C. and bath 12 mm thick for dado in
cement mortar 1;3 with neat finishing, floating using waterproofing
compound at the rate of 1 kg. per bag of cement approved make and
manufacturer and curing etc. complete. (Excluding tiles).
(PWDSR.2013/14, P.N.38,I.N.15)

Spec: (As directed by Engineer in charge)


16 Lowering down the debris obtained from removing tiles / kitchen otta
from the first floor by any means without causing dust nuisance and
damage to structure , stacking the same as and where directed
including cleaning the site complete. (Rate for loose material).
(PWDSR.2013/14, P.N.38,I.N.16)

Spec: (As directed by Engineer in charge)


PAGE NO : 38
17 Providing and laying water proofing treatment to RCC terrace slab
with NILOBIT/STP/ PN-3 mm thick APP modified bitumen
membrane with polymer reinforcement with overlapping of 75 mm
along length and 100 mm along width including removing the tarfelt
treatment without causing damages to the existing structure cleaning
the terrace surface neatly with removing the dust and loose portion,
including applying the bitumen based primer @ 0.20 ltr / Sqm and
laying the 3 mm thick NILOBIT PN-3 mm thick APP modified
bitumen membrane coating with torching method and finishing
surface with heat reflective bitumen based silver paint @ 0.10 Ltr /
Sqm and covering the hole treatment with five years guarantee, on
requisite stamp paper etc. complete.(PWDSR.2013/14, P.N.39,I.N.17)

Spec: (As directed by Engineer in charge)


18 Providing waterproofing treatment by roof guard system (Burger
Paint) to terrace and external wall by using Jet Water Pressure
Machine. Scraping the surface of concrete, IPS, China Mosaic with tar
brush. Remove paints, chemicals, dammar by using Jet Water Pressure
Machine. Washing the area with clean water, opening the cracks of top
surface and making the same in 'V' shape. Filling the cracks with crack
X paste in 2 coats in the intervel of 4 to 6 hrs. allow to dry for 4 to 6
hrs. Apply 1st coat of Roof Guard Base Coat of Burger Paints by
using brush, allow to dry for 24 hrs. Sanding the surface and apply 1 st
coat Guard base Coat and allow it to dry for min 24 hrs. Sanding the
surface and apply 1st coat of Roof Guard Top Coat of Burger paints
and allow it to dry for 6 to 8 hrs. Apply 2nd coat Roof Guard Top Coat
and should done by authorised applicator on Burger paint, with five
years guarantee on requisite stamp paper etc. complete.
(PWDSR.2013/14, P.N.39,I.N.18)

Spec: (As directed by Engineer in charge)


19 Removing any kind of debris including loading in truck and conveying
to dumping point approved by BMC, unloading, spreading etc.
complete. With all leads and lifts.(PWDSR.2013/14, P.N.39,I.N.19)

Spec: (As directed by Engineer in charge)


PAGE NO : 39
New Items
Note : The following all new items may be used on experimental basis for one year only.
20 Waterproofing Treatment to existing Terrace by Using Polymeric cement
Spec: (As directed by Engineer in charge)
21 Providing and injecting High molecular weight Super low viscous (3 to
Spec: (As directed by Engineer in charge)
PAGE NO : 40
22 Providing and injecting High performance non shrink, free from high s
Spec: (As directed by Engineer in charge)
Note : Prior permission of S.E. In writing is necessary before inclusion of this item in the estim
23 Provding water proofing treatment to Bath and W.C sunk by applying fir
Spec: (As directed by Engineer in charge)
PAGE NO : 41
24 Providing and applying external raincoat painting with crack filling
Pidilite Company Product Dr. Fixit Rain Coat acrylic polymer based
chemical compound coating to the external surface of wall to prevent
water seepage in the masonry walls during monsoon added with
required shade Steiner to give required shade to the surface in two
coats. Including providing three coat of priming of Dr. Fixit Prime
Seal polymer base primer including preparing surface scrapping the
existing loose old paint, removing loose particles of sand on the
surfaace openng and cleaning the cracks developed in the external
plaster, removing loose particles by chiseling, filling cracks by
chemicals compound of Dr. Fixit Crack-x with proper penetration etc.
Coating of Raincoat with the help of brush and as per instructions and
specification given by Pedilite and with instruction from Engineer in-
charge. Work shall be executed by certified applicator only and
covering gurantee of 3 years on court sramp paper of Rs. 500/- and
necessary testing etc. complete. (PWDSR.2013/14, P.N.42,I.N.24)

Spec: (As directed by Engineer in charge)


25 Providing and installing INTEGRAL CRYSTALINE waterproofing treatment b
Spec: (As directed by Engineer in charge)
PAGE NO : 42
26 Providing and application of swellable type water stop Penebar for CON
Spec: (As directed by Engineer in charge)
27 Providing and application of INTEGRAL CRYSTALINE
waterproofing treatment for retaining wall area (for raft also if
thickness is less than 400 mm) by using to the entire quantity of the
concrete Penetron Admix having speed of penetration of 31 Cm in 56
days and resistance to 20 bar hydrostatic water head of M/s. ICS
Penetron International Ltd. USA @ 0.8 % by weight of cementatious
content. The material must qualify as PRAH grade PERMEABILITY
REDUCING ADMIXTURE FOR HYDROSTATIC conditions and
meet the following requirements Specified in ACI-212-3R-2010 at the
recommended dosage rate of 0.8% by weight of cementatious
materials which is Capable of reducing Permeability of concrete by
more than 90% , compared with control concrete, when tested as per
DIN 1048 (after applying 4 cycles of hydrostatic pressure) and
permeability co-efficient calculated as per Valenta/ Darcy's formula
and using approved as per DIN 18998 with chloride content less than
0.1%, alkali content less than 9.3% and no negative effect on
corrosion of steel reinforcement. Work shall be carried out as per the
approved method of waterproofing accepted by the Engineer in-
charge. Work shall be executed by certified aplicator only and shall be
guaranteed for 10 years against any leakages an guarantee shall be
provided on Rs.500/- stamp paper in approved proforma.
(PWDSR.2013/14, P.N.43,I.N.27)
Spec: (As directed by Engineer in charge)
PAGE NO : 43
28 Providing and application of INTEGRAL CRYSTALINE waterproofing treat
Spec: (As directed by Engineer in charge)
PAGE NO : 44
29 Prioviding and applying specialized waterproofing treatment to
HEAVILY LEAKAGE AFFECTED AREA OF EXTERNAL WALL
by Using Polymeric Cementitious Membrance with a coat of anti
fungal treatment (SUNANTIFUNGAL SP- SUNANDA MAKE) to
entire surface of wall. Applying one coat of polymeric water proofing
coating ( POLYALK WP - SUNANDA MAKE) having a breathable
non toxic acrylic polymer liquid and grey cement mix in proportion
1:1 by weight with coat interval as 24 hours. Before giving this
treatment the entire surface of wall shall be thoroughly clean to
remove existing paint, dust, dirt, etc. The cracks, if any, shall be filled
with acrylic polymeric non shrink crack filler putty- (POLYFILL AR-
SUNANDA MAKE), before giving waterproofing treatment to the
external surfaces. Applying Waterproof, anti carbonation, anti fading,
mould resistant, heat insulating, and 100% acrylic breathable
decorative external coating (SUNEXT 8- SUNANDA MAKE) Mix 1
L of with 400ml of water, stir well and apply by brush for two coats.
Applying two coats at an interval of 4-6 hours between each coat.
work shall be executed by certified applicator only and work shall be
guaranteed for 3 years and guarantee shall be provided on Rs.500/-
stamp paper.(PWDSR.2013/14, P.N.45,I.N.29)

Spec: (As directed by Engineer in charge)


PAGE NO : 45
30 Providing water proofing treatment to ....... By SEALING OF
CRACKS by non shrink crack fill compound applying first coat of
polymer modified semi-viscous paste prepared by mixing polymer of
approved make (such as Polyalk EP/ Master Seal 550/Brush bond
/Roff supercrete /Webercrete/ Monobond /Perma shield /Hypercrae
/Master Crete M 81) and Cement in 1:2 proportion (1 Litre Polymer :
2 Kg Cement) or Rohnex water proofing system in two coats (1Kg
powder, 700 ml water and polymer jelly for first coat & 1 Kg powder,
500 ml water and polymer jelly for second coat) to a neatly cleaned
and dust free concrete surface and upto 300 mm over parapet wall
prepared by removing loose and deposited material with brush and
water, followed by two coats of flexible cementious coating e.g. MYK
Aquafine UM/Sunanda Polyalk WP, EL Monobond coat or
equiavalent as per manufacture's specifications after laying glass fivre
mesh of 10 x 10 specification of approved make over tacky surface of
first coat of coating followed by second coat in transverse directin,
sprinkling coarse sand over it, followed by protective mechanical
cover of 40 mm to 75 mm. thick cement concrete of 1:2:3 proportion
using coarse aggregate of 10 MSA and water proofing compound of
approved make and polypropylene fivres @ 125 gm per bag of cement
within in conforming to IS, in pannels of 3m /4m or as per site
condition and filling the joints with polysulphide sealant (0.12 KG per
square meter) after curing including providing holler with driop
moulds at the junction and finishing the concrete surface with cement
sand mortar 1:2.5 with high performance highly impermeable polymer
e.g. Superscreed P o equivalent surface with neat cement slurry
including curing as directed and ponding the surface as directed etc.
complete; covering 10years guarantee against leakproofness on Court
Fee Stamp Paper of Rs. 100/- (Note: for salanting length upto 5.0m)
(Excluding grouting and Removing existing treatment, to be paid
separately as required) .(PWDSR.2013/14, P.N.46,I.N.30)
Spec: (As directed by Engineer in charge)
a) Newly laid fully cured concrete slab
b) Old terrace
PAGE NO : 46
31 Providing and applying water proofing treatment to exposed
reinforcement portion for ......... With one coat of alkaline RUST
CONVERTER feouert/Rusticide or equivalent on exposed
reinforcement after cleaning the surface with wire brush, followed by
two coates of anticorrosive epoxy phenolic IPNET RB/ POLYALK
FLXOPRIME or equivalent rebar protection coating on exposed
reinforcement and concrete penetrating corrosion inhibitor EPCO KP-
100/POLYALK CP 113 or equivalent over adjoining concrete
surfaced. (PWDSR.2013/14, P.N.47,I.N.31)

Spec: (As directed by Engineer in charge)


a) Slab
b) Beam / Column
32 Repairs to RCC Damaged Members such as slab, beam, columns by
using Readymix Polymer Modified Mortar (upto 20 mm thick).
Removing loose rust from the reinforcement bars by wire brushing,
light hammering etc. And applying sulphate and chloride free
inorganic single component rut remover (RUSTICIDE - SUNANDA
MAKE) conforming to IS 9077. The rusted surface shall become
blackish non rusted colour. After 24 hours of application of rust
remover, loose particles shall be removed by brush. Applying bonding
coat slurry of high performance acrylic polymer POLYALK EP of
Sunanda Make or equivalent over Ready mix polymer modified
mortar. Mix 1Kg Polyalk EP with 0.5 Kg of cement. Finish with ready
to use repair polymer modified mortar (SUNMIX- SUNANDA
MAKE). by adding 13-16 % water by weight of SUNMICX for
treatment to the damaged RCC members. Add 1Kg of Bipolar
Concrete Penetrating Corrosion Inhibiting Admixture - POLYALK CP
293 per 25 Kg bag of SUNMIX After mixing SUNMIX can be
sprayed or trowel applied. When applying by hand SUNMIX must be
forced tightly into the substrate to ensure complete contact with the
substrate. Work shall be executed by certified applicator only and
work shall be guaranteed for 5 years and guarantee shall be provided
on Rs. 500/- stamp paper.(PWDSR.2013/14, P.N.47,I.N.32)

Spec: (As directed by Engineer in charge)


PAGE NO : 47
33 Provding and fixing zinc based galvanic disk type anodes
(SUNANODE- SUNANDA MAKE) or Canode of Krishna Make or
equivalent to the reinforcement, as directed. The anode shall be
connected to the reinforcement steel by connectors provided with the
anode application area is at the junction of repair. one anode per meter
including tying to bar etc. complete Work shall be executed by
certified applicator only and work shall be guaranteed for 5 yeas and
guarantee shall be provided on Rs. 500/- stamp paper.
(PWDSR.2013/14, P.N.48,I.N.33)

Spec: (As directed by Engineer in charge)


34 Providing Terrace Water proofing system with Dr. Fixit Newcoat
including mechanical cleaning of the external surface and treating
surface in sound, clean and fee from dirt, oil and other loose material
and may be done with vaccum cleaning if required. All surface cracks
upto 5 mm width will be filled up with Dr. Fixit Crack X Paste (or
equivalent BERGER/ ASAIN / BASF/ FOSROC / STP ). The external
surfaces will be primes with dr. Fixit Primeseal (or equivalentA BASF
/ FOSROC / STP ) diluted with potable water in theA ratio ofA 2:1 by
volume prior to application of Dr. Fixit Newcoat or equivalent
(BASF / FOROC / STP ). Allow it to dry for at least 2 to 3 hours and
then apply Dr. Fixit Newcoat (As per technical data enclosed with
BOQ) Apply three coats of Newcoat with different shades colors for
better monitoring with time interval of 6-8 hrs betwwen each coat. The
application of each coat shall be in perpendicular direction to the
subsequent coat. Allow Newcoat to air cure for 3 to 4 days before
subjecting to use / foot traffic Allow it to air cure for 7 days and (do
not dilute Dr. Fixit Newcoat by any means). Work shall be executed by
certified applicator only and work shall be guaranteed for 5 years and
guarantee shall be provided on Rs. 500/- stamp paper.
(PWDSR.2013/14, P.N.48,I.N.34)

(As directed by Engineer in charge)


PAGE NO : 48
35 Providing and applying Exterior Coating (For Wall & Parpet)
including mechanical cleaning of the external surface and treating
surface in sound, clean and fee from dirt, oil and other loose material
and may be done with vacuum cleaning if required. All surface cracks
upto 5mm. width will be filled up with Dr. Fixit Crack X Paste or
similar material.A The external surface will be primed with Dr. Fixit
Primeseal (or equivalentA BASF / FOSROC / STP ) diluted with
potable water in theaA ratio ofA 2:1 by volume prior to applicatiion of
Dr. Fixit Raincoat. Allow it to dry for at least 2 to 3 hours and then
apply Dr. Fixit Raincoat or Eqivalent (BASF / FOSROC / STP )
having DFT of micron, elongation of > 100 % as per ASTM D-412-
02 and algae & fungal resistance as per SS 345-1998. Accelerated
weathering (2000 Hrs UV Exposure) as per ASTM D4587 aE No
defects ) in 2 coats by brush, roller or spray with an interval of 5 to 6
hrs. Allow it to air cure for 7 days and (do not dilute Dr. Fixit Raincoat
by any means). Work shall be executed by certified applicator only
and work shall be guaranteed for 5 years and guarantee shall be
provided on Rs. 500 /- stamp paper..(PWDSR.2013/14, P.N.49,I.N.35)

(As directed by Engineer in charge)


PAGE NO : 49
36 Providing Terrace Water proofing System for New Construction
including mechanically clean the RCC slab and wall with wire brush /
coir brush to free from all loose materials like dust, dirt etc. Make
wattah / coving of 50x50 mm at all horizontal & vertical joints to
avoid right angel turning. Seal all honeycombs, pin holes, joints, pipe
outlets wiht Polymer Modified Mortar. Also pouring Dr. Fixit
Pidigrout 5M (or equivalent BASF / FOSROC / STP ) (expansive,
non-shrinking grout) in the gaps around the plumbing pipes or joints
on through pre-wetted condition with water attaining a SSD condition.
Providing and applying one coat of polymer modified bituminous
emulsion (1.5 Kg/ sq.mtr) having elongation of > 300% Dr. Fixit
Solyseal (or equivalent BASF / FOSROC / STP) Impermeability as
per AST M E 96 : 94 is 0-5 gm/sqm. (Full cured in 24 hrs.) / System
Adhesions perA AST M C836: 89A is Energy > 4.00 j /A Crack
Bridging as per AST M C836: 00 is No crack at 2 mm gap / Hardness,
Shore A as perA AST M D2240: 91 isA > 50 / Water Penetration as per
DIN 1048: Pt 5: 91 is No penetration / Tensile Strength, N/ mm2 as
per AST M D412 is 0.3.), Laying of 140-160 gsm geo textile on first
coat as reinforcement. After drying of first coat apply second coat (1.5
kg / sqmtr) of Dr. Fixit Solyseal and allow it to be cured. Providing
and laying 140-160 gsm geo-textile fleece on top of Dr. Fixit
Solyseal .For protection of waterproofing treatment scredd / brick bat
coba / china mosaic / light weight concrete to be provided at extra
cost as per site requirement. Note: Work shall be executed by certified
applicator only and work shall be guaranteed for 5 years and guarantee
shall be provided on Rs. 500/- stamp paper..(PWDSR.2013/14,
P.N.50,I.N.36)

Spec: (As directed by Engineer in charge)


PAGE NO : 50
37 Providing Terrace Water proofing system for Old Constructions
including mechanically clean the RCC slab and wall with wire brush /
coir brush to fee from all loose materials like dust, dirt etc. Make
wattah / coving of 50x50 mm at all horizontal & vertical joints to
avoid right angle turning. Seal all honeycombs, pin holes, joints, pipe
outlets with Polymer Modified Mortar. Providing and applying one
coat primer with Dr. Fixit Torchshield Primer (or equivalent Texsa /
FOSROC / STP). Solvent based bitumen modified primer conforming
to ASTM D-41 to be used to seal and prepare the substrate prior to the
installatio of Dr. Fixit Torchshield (or equivalent Texsa /BASF /
FOSROC / STP ). Providing and applying Dr. Fixit Torchshield (with
elongation break up as per EN-12311-1 =L-40% t-40%, Tensile
strength (N/5cm)= L-700 & T=450, Tear strength as per ASTM-
D5147 = L-300 N & T-250N, Cold flexibility as per EN-1109 (upto 20
C) = -5, Softening pont as per EN-1110 (oC) < 150, water absorption
as per En-1928 = -0.15% Max) (or equivalent Texsa / BASF /
FOSROC / STP) with proper alignment and minimum overlap of
100MM with proper application method, For protection of
waterproofing treatment screed / brick bat coba / china mosaic / light
weight concrete to be provided at extra cost as per site requirement.
Work shall be executed by certified applicator only and work shall be
guaranteed for 5 years and guarantee shall be provided on Rs. 500/-
stamp paper. (PWDSR.2013/14, P.N.51,I.N.37)

Spec: (As directed by Engineer in charge)


a) For 3 mm thick
b) For 4 mm thick
PAGE NO : 51
38 Providing Waterproofing of Water tanks with Dr. Fixit Pidifin2k and
Dr. Fixit Safeguard and fixing of Dr. Fixit Waterbar SW2020 (or
equivalent BASF / FOSROC / STP) on all construction joints like slab
& wall, lift joints etc. During concreting work is on. Mechanically
clean the RCC slab and wall with wire brush / coir brush to free from
all loose materials like dust, dirt etc. Seal all honeycombs, pin holes,
joints with Polymer Modified Mortar attain SSD condition. Apply first
coat of Dr. Fixit Pifin2k( or equivalent BASF / FOSROC / STP ) rapid
chloride permeability reduction in chloride ion penetratiion, is 90 % as
per ASTM C 1202 : on properly rencdered, cleaned RCC slab & wall
with brush and allow it to dry for 6-8 hrs. After drying of first coat
apply second coat and sprinkled coarse sand on vertical surface. Allow
24 hrs for full cure. Apply waterproof screed concrete 30-40 mm on
floor and 12-15 mm waterproof plaster on vertical surface before
admixed with Dr. Fixit Pidiproof LW + (or equivalent BASF /
FOSROC / STP) IS : 2645 : as per standard @ 200ml per bag of
cement. Cure the surface with water. Clenan the surface with wire
brush to remove all loose dust, dirt etc, Saturate the surface with water
to reach SSD condition. Apply two coats of Dr. Fixit safeguard (or
equivalent BASF / FOSROC / STP ) ((pot life at30C, hrs is 60-75,
Surface drying time at 30C as per ASTM D-1649 6-8, Water
absorption as per AST C 870:90 - NIL, Food Grade certification
PASSES- Ref- USFD-175-300, Antifungal Activity as per EN 15458-
06 ) by brush on SSD floor & wall by brush on an interval of 6-8 hrs
in between 2 coats. Allow the surface for full cure of 24 hours before
use. Work shall be executed by certified applicator only and work shall
be guaranteed for 5 years and guarantee shall be provided on Rs.500/-
stamp paper.(PWDSR.2013/14, P.N.52,I.N.38)

Spec: (As directed by Engineer in charge)


PAGE NO : 52
39 Providing Terrace Water proofing system for Old Constructions
Mechanically clean the RCC slab and wall with wire brush / coir brush
to free from all loose materials like dust, dirt etc. Make wattah /
coving of 50x50 mm at all horizontal & vertical joints to avoid right
angle turning. Seal all honeycombs, pin holes, joints, pipe outlets with
Polymer Modified Mortar. Providing and applying one coat primer
with Dr. Fixit torchshield Primer (or equivalent Texsa / FOSROC /
STP ). A Solvent based bitumen modified primer conforming to
ASTM D-41 to be used to seal and prepare th substrate prior to the
instllation of Dr. Fixit Torchshield Mineral finish Green Color (or
equivalent Texsa / BASF / FOSROC / STP ). Providing and applying
Dr. Fixit Torchshield Mineral Finish green Color (with elongation
break up as per EN-12311-1 = L-40% T-40% , Tensile strength
(N/5cm) = L-700 & t=450, Tear strength as per ASTM - D5147 = L-
300 N & T-250N, Cold flexibility as per EN-1109 (upto2o C) = -5,
Softening point as per EN-1110 (oC) < 150, water absorption as per
EN-1928 = -0.15 % Max) (or equivalent Texsa / BASF / FOSROC /
STP), with proper alignment and minimum overlap of 100MM with
proper application method, For protection of waterproofing treatment
screed / brick bat coba / china mosaic / light weight concrete to be
provided at extra cost as per site requirement. Work shall be executed
by certified applicator only and work shall be guaranteed for 5 years
and guarantee shall be provided on Rs. 500 /- stamp paper.
(PWDSR.2013/14, P.N.53,I.N.39)

Spec: (As directed by Engineer in charge)


a) For 3 mm thick Mineral finish Green Color
b) for 4 mm thk Mineral finish Green Color
PAGE NO : 53
40 Providing Waterproofing of Wet Areas with Bathseal system of Dr.
Fixit (Regular Option) including mechanically clean the RCC slab
surface and side walls with wire brush / coir brush to free from all
loose material like dust, loose particles, dirt, etc. Seal all honeycombs,
pin holes, joints, pipe outlets with Polymer Modified Mortar (1:5:10).
Also apply, around all PVC / CI pipeds fixed in toilet waterproofing
system Dr. Fixit Bathseal Tape (or equivalent BASF / FOSROC / STP)
/ Crack Bridging ability is > 1.5 MM as per ASTM C 838 ), a non
reinforced twin side adhesive bitumen membrane comprising of
polymerised bitumen, sandwiched between plastic released films on
either side, then using Dr. Fixit Pidigrout 5M ( expansive, non-
shrinking grout ) in the gaps around the plumbing pipes where
bathseal tape has been used, after attaining a SSD conditon, Making
first coat of Dr. Fixit Pidifin 2K (or equivalent BASF / FOSROC /
STP ) (sP. gRAVITY @ 30 Degree, g/cc is 1.65 + 0.10/ Abrasuib
resustabcem cm/km is 0.09 / rapid chloride permeability reduction in
chloride ion penetration, is 90% as per ASTM C 1202 : 1997 /
properly rendered, cleaned RCC slab & side walls with brush and
allow it to dry for 6-8 hrs. After drying of first coat, apply second coat
and sprinkled coarse sand on vertical surface. The Pidifin 2K Coating
should continue up to 4 feet above finished floor level. Allow 244 hrs
for full cure. Apply 12-15 mm waterproof plaster on slab & vertical
surface before admixed with Dr. Fixit Pidiproof LW+ (or equivalent
BASF / FOSROC / STP) IS2645 Dosage 200ml per bag of cement.
Cure the surface with water. Work shall be executed by certified
applicator oly and work shall be guarantedd for 5 years and guarantee
shall be provided on Rs. 500 /- stamp paper.(PWDSR.2013/14,
P.N.54,I.N.40)

Spec: (As directed by Engineer in charge)


PAGE NO : 54
BD-K : EXPANSION JOINTS
1 Providing Expansion joints in Reinforced Cement Concrete framed
structure …….. With plain premoulded filler 25 mm thick including 3
mm aluminium plate, fixing teak wood battens on both faces and
finishing as directed etc. complete.(PWDSR.2012/13, P.N.55,I.N.1)

Bd/K-1 P-359 a) for interior column


Bd/K-1 P-359 b) for exterior column
Bd/K-1 P-359 c) at floor level
Bd/K-1 P-359 d) at terrace level
2 Providing Expansion Joints in Reinforced Cement concrete framed
structure …….. with plain premoulded filler 60 mm thick including 3
mm aluminium plate, fixing teak wood battens on both faces and
finishing as directed etc. complete.(PWDSR.2013/14, P.N.55,I.N.2)

a) for interior column


b) for exterior column
c) at floor level
d) at terrace level
Spec: (As directed by Engineer in charge)
PAGE NO : 55
BD-L : PLASTERING AND POINTING
1 Providing internal cement plaster 6 mm thick in single coat in ……
without neeru finish to concrete surface in all positions including
scaffolding, curing complete.(for old work only)(PWDSR.2013/14,
P.N.57,I.N.1)
Bd/L-1 P-367 a) cement mortar 1:3
Bd/L-1 P-367 b) cement mortar 1:4
2 Providing internal cement plaster 12 mm thick in single coat in ……
without neeru finish to concrete or brick surface in all positions
including scaffolding, and curing complete.(for old work only)
(PWDSR.2013/14, P.N.57,I.N.2)
Bd/L-2 P-368 a) cement mortar 1:3
Bd/L-2 P-368 b) cement mortar 1:4
Bd/L-2 P-368 c) cement mortar 1:5
3 Bd/L-3 P-368 Providing internal cement plaster 20 mm thick in single coat in cement
mortar 1:4 without neeru finish to stone masonry surface in all
positions including scaffolding and curing complete.
(PWDSR.2013/14, P.N.57,I.N.3)
4 Providing internal cement plaster …… in all positions including
scaffolding and curing complete.(PWDSR.2013/14, P.N.57,I.N.4)
Bd/L-4 P-368 a) 20 mm thick in a single coat in cement mortar 1:5 without neeru
finish to concrete or brick surfaces
Bd/L-4 P-368 b) 20 mm thick in two coats in cement mortar 1:4 without neeru finish
to concrete or brick surfaces
5 Bd/L-5 P-368 Providing internal cement plaster 25 mm thick in two coats in cement
mortar 1:4 without neeru finish to concrete, brick or stone surfaces in
all positions including scaffolding and curing complete.
(PWDSR.2013/14, P.N.57,I.N.5)
PAGE NO : 57
6 Bd/L-7 P-369 Providing sand face plaster externally to concrete stone or brick
surfaces using approved screened sand including preparing the base,
watering and applying base coat of 15 mm thick in cement mortar 1:4
using water proofing compound at the rate of 1 kilogramme per
cement bag and curing the same for not less than two days and
keeping the surface of base coat rough to receive the sand faced
treatment not to exceed 8 mm thickness in cement mortar 1:4 and
finishing the surface by taking out grains and curing for 14 days and
scaffolding etc. complete. (PWDSR.2013/14, P.N.58,I.N.6)
7 Bd/L-8 P-370 Providing rough cast cement plaster externally in two coats to concrete
/ brick/stone masonry in all positions including preparing the base,
watering and applying base coat of 12 to 15 mm thick in cment mortar
1:4 using water proofing compound at the rate of 1kg per 50kg of
cement and rough cast treatment 12 mm thick in proporation 1:11/2:3
including scaffolding and 14 days curing etc. complete.
(PWDSR.2013/14, P.N.58,I.N.7)

8 Bd/L-10 Providing neeru finish to plastered surfaces in all positions including


P-371 scaffolding, and curing complete.(PWDSR.2013/14, P.N.58,I.N.8)
9 Bd/L-11 P-371 Providing exterior stone-crete facing of approved colour and dressing
to brick/stone/concrete surfaces in all positions preparing the base,
watering with base coat of 12 to 15mm thick in cement mortar 1:3
using water proofing compound at the rate of 1kg. per 50 kg. of
cement bag including final coat for stone-crete facing of requried
thickness not less than 12mm thick in proporation of 1:3 using gray
cement and colour pigment including scaffolding and 14 days curing
etc. complete. (PWDSR.2013/14, P.N.58,I.N.9)

10 Providing flush grooved pointing to ……. With cement mortar 1:3


including scaffolding and curing complete.(PWDSR.2013/14,
P.N.58,I.N.10)
Bd/L-15 P-372 a) brick masonry

Bd/L-15 P-372 b) stone masonry

PAGE NO : 58
11 Bd/L-16 P-373 Providing Tuck pointing to stone masonry/brick work with cement
mortar 1:3 including scaffolding and curing complete.
(PWDSR.2013/14, P.N.59,I.N.11)
12 Bd/L-17 P-373 Providing Weathered pointing to stone masonry/brick work with
cement mortar 1:3 including scaffolding and curing complete.
(PWDSR.2013/14, P.N.59,I.N.12)
13 Bd/L-18 P-375 Providing Vee pointing to stone masonry/brick work with cement
mortar 1:3 including scaffolding and curing complete.
(PWDSR.2013/14, P.N.59,I.N.13)
14 Removing the existing cement plaster of any thickness without
causing dust nuisance and stacking the debris upto a distance of 50
metres or spreading in the compound and cleaning the site etc.
comlpete.(PWDSR.2013/14, P.N.59,I.N.14)
Spec: (As directed by Engineer in charge)
Note : Following items to be executed after prior approved of
superintending Engineer
15 Providing 6 mm thick P.O.P. finish in single coat to concrete or brick
surface in all positions including scaffolding etc. complete.
(PWDSR.2013/14, P.N.59,I.N.15)
Spec: (As directed by Engineer in charge)
16 Providing 12 mm thick P.O.P. finish in single coat to concrete or brick
surfaces in all positions including scaffolding etc. complete.
(PWDSR.2012/13, P.N.39,I.N.16)
Spec: (As directed by Engineer in charge)
17 Providing and erecting single scaffolding for painting, water supply
and sanitary pipe line repair works using bamboo male of 1" to 1-1/2
"dia. Vertical and Horizontal at 1.20 mtr. and necessary cross bamboos
and short bamboos for supports from bldg. by taking necessary holes
in wall and remaking good the damages after completion of work,
including coir and all necessary material including conveying loading
unloading including removing the same offer completion of work by
taking necessary precautions and safety measures of labour etc.
(PWDSR.2013/14, P.N.59,I.N.17)

Spec: (As directed by Engineer in charge)


PAGE NO : 59
18 Providing and erecting double scaffolding for external plaster and
other repair works using bamboo male of 1" to 1-1/2 ''dia. Vertical and
Horziontal at 1.20 mtr. and necessary cross bamboos and short
bamboos for supports from building and providing and fixing planks
by taking necessary holes in wall and reamking good the damages
after completion of work, including coir and all necessary material
including conveying loading unloading including removing the same
offer completion of work by taking necessary precautions and safety
measures of labour etc.(PWDSR.2013/14, P.N.60,I.N.18)

Spec: (As directed by Engineer in charge)


19 Providing and erecting mat scaffolding for ceiling plaster and other
repair works using bullies /bamboos, planks, coir including taking all
necessary precaution and safety measures of labour, material with
conveying, all lead and lift including removing the same after
completion of the work etc. complete. for height upto 5.0 metre.
(Irrespective of duration of scaffold, the item will be paid only once).
(PWDSR.2013/14, P.N.60,I.N.19)

Spec: (As directed by Engineer in charge)


New Items
Note : The following new item may be used on experimetal basis for one year only
20 Providing GBP Eco Render Plus (Eco Friendly, Pre Polymerised, self cur
Spec: (As directed by Engineer in charge)
PAGE NO : 60
BD-M : PAVING, FLOOR FINISHING AND DADO
1 Providing and laying Rough shahabad stone flooring of approved
quality…….. and 30cm wide in plain/ diamond pattern laid on bed of
cement mortar 1:6 including cement float above mortar bedding,
striking joints/ cement pointing in mortar 1:3, curing and cleaning etc.
complete.(PWDSR.2013/14, P.N.61,I.N.1)

Bd/M-1 P-379 a) 25 mm to 30 mm thick


Bd/M-1 P-379 b) 25 mm to 30 mm thick on sand bed

2 Providing and laying polished…….. Flooring of approved quality 25


mm to 30 mm thickand 30 cm wide in plain / diamond pattern laid on
a bed of cement mortar 1:4 including cement float, filling joints with
neat cement grout/slurry, curing, polishing and cleaning complete.
(PWDSR.2013/14, P.N.61,I.N.2)

Bd/M-3 P-380 a) Shahabad Stone

Bd/M-3 P-380 b) Tandur Stone

3 Providing and laying polished…….. Flooring of approved quality 25


mm to 30 mm thick and having size not less than 55 cm x 55 cm in
plain / diamond pattern laid on a bed of cement mortar 1:6 including
cement float, filling joints with neat cement slurry, curing, polishing
and cleaning complete.(PWDSR.2013/14, P.N.61,I.N.3)

a) Shahabad Stone
b) Tandur Stone
c) Kotah Stone
PAGE NO : 61
4 Bd/M-16 P- Providing and laying machine cut mirror polished-Granite stone slab
387 60 cm x 45 cm and 16 mm to 18 mm thick of approved quality veins
and colour for flooring in requried pattern laid on a bed of cement
mortar 1:6 including neat coloured cement slurry, curing, hand
polishing and cleaning complete.(PWDSR.2013/14,P.N.62,I.N.4)

(*) (Except granite slab of specified size and thickness shall be used)
5 Providing and fixing machine cut mirror polished Granite stone slab
60 cm x 45 cm and 20 mm and 16 mm to 18mm thick of approved
quality, vein and colour for dado and stirting fixed on base plaster on
cement mortar 1:4 including filling joint with neat coloured cement
slurry, curing, hand polishing and cleaning complete.
(PWDSR.2013/14, P.N.62,I.N.5)

(*) (Except granite slab of specified size and thickness shall be used)
6 Providing and fixing in requried position skirting or dado of …….
Slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar
1:4 including cement float, filling joints with cement slurry, curing,
rubbing, polishing and cleaning complete. (PWDSR.2013/14,
P.N.62,I.N.6)

Bd/M-5 P-381 a) Polished Shahabad Stone

Bd/M-5 P-381 b) Polished Tandur Stone

Bd/M-5 P-381 c) Polished Kotah Stone


7 Providing and laying cement concrete flooring …… with M-20
cement concrete laid to proper line level and slope in alternate bays
including compaction, filling joints, marking lines to give the
appearance of tiles of 30 cm x 30 cm or other size, as specified and
laid diagonally or square, finishing smooth (with extra cement) in any
colour as directed, and curimg complete. (PWDSR.2013/14,
P.N.62,I.N.7)

Bd/M-6 P-381 a) 40 mm thick

Bd/M-6 P-381 b) 50 mm thick

PAGE NO : 62
8 Providing and laying cement concrete flooring …… with M-15
cement concrete laid to proper line level and slope in alternate bays
including compaction, filling joints, marking lines to give the
appearance of tiles of 30 cm x 30 cm or other size as specified and laid
diagonally or square, finishing smooth (with extra cement) in any
colour as directed and curing complete.(PWDSR.2013/14,
P.N.63,I.N.8)

Bd/M-7 P-383 a) 40 mm thick

Bd/M-7 P-383 b) 50 mm thick

9 Providing and laying ….. of size 25 cm x 25 cm for flooring laid on a


bad of cement mortar 1:4 including neat cement float, filling joints
with neat cement slurry, curing, machine polishing and cleaning etc.
complete (without border/with border/with pattern of cement tiles of
approved colour).(PWDSR.2013/14, P.N.63,I.N.9)

Bd/M-8 P-383 a) plain cement tiles

Bd/M-10 P- b) coloured cement tiles


384
10 Providing and fixing ……. in required position fixed on base plaster
of cement mortar 1:4 including, filling jonts with neat cement slurry,
curing, rubbing, polishing and cleaning complete.(PWDSR.2013/14,
P.N.63,I.N.10)
BdM-9 P-383 a) plain cement tiles for dado and skirting
Bd/M-11 P/- b) coloured cement tiles for dado and skirting
384
PAGE NO : 63
11 Providing and laying ……. of 200 x 100 mm in size and 8 to 9.5 mm
thick for flooring in requried positions laid on a bed of cement mortar
1:4 including neat cement float, all special requried like round, edge
tiles, corner cups etc. filling joints with neat cement slurry mixed with
approved shade of pigment to match the colour of tiles, curing and
cleaning complete. (PWDSR.2013/14, P.N.64,I.N.11)
Bd/M-12 P- a) white glazed tile
385 (*)
(*) (Except that white glazed tiles of specified size and
thickness shall be used)
Bd/M-12 P- b) coloured glazed tile
385 (*)
(*) (Except that coloured glazed tiles of specified size
and thickness shall be used)
12 Providing and fixing ……. of 200 x 100 mm in size and about 6.5 mm
thick for dado and skirting in requried positions fixed on plaster of
cement mortar 1:4 including neat cement float, all special requried like
round, edge tiles, corner cups etc. filling joints with neat cement slurry
mixed with approved shade of pigment to match the colour of tiles,
curing and cleaning etc. complete.(PWDSR.2013/14, P.N.64,I.N.12)

Bd/M-13 P- a) white glazed tile


386 (*)
(*) (Except that white glazed tiles of specified thickness shall be used)

Bd/M-13 P- b) coloured glazed tile


386 (*)
(*) (Except that coloured glazed tiles of specified size
and thickness shall be used)
PAGE NO : 64
13 Providing and laying plain ceramic tiles of size ……. and above 6 to 8
mm thick for flooring in requried position laid on bed of cement
mortar 1:4 including neat cement float, filling joints with neat cement
slurry, curing and cleaning complete. (PWDSR.2013/14,
P.N.65,I.N.13)

Bd/M-12 P- a) 300 mm x 300 mm


385 (*)
(*) (Except that plain ceramic tiles of specified size
and thickness shall be used)
Bd/M-12 P- b) 300 mm x 200 mm
385 (*)
(*) (Except that plain ceramic tiles of specified size
and thickness shall be used)
Bd/M-12 P- c) 450 mm x 450 mm or larger size
385 (*)
(*) (Except that plain ceramic tiles of specified size
and thickness shall be used)
14 Providing and laying decorative ceramic tiles of size …… and above 6
to 8 mm thick for flooring in required position laid on bed of cement
mortar 1:4 including neat cement flaot, filling joints with neat cement
slurry, curing and cleaning complete. (PWDSR.2013/14,
P.N.65,I.N.14)
Bd/M-12 P- a) 300 mm x 300 mm
385 (*)
(*) (Except that decorative ceramic tiles of specified size and
thickness shall be used)
Bd/M-12 P- b) 300 mm x 200 mm
385 (*)
(*) (Except that decorative ceramic tiles of specified size and
thickness shall be used)
15 Providing and fixing plain ceramic tiles of size …… and above 5 to 6
mm thick for dado and skirting in requried position fixed on plaster of
cement mortar 1:4, neat cement paste, filling joints with neat cement
slurry, curing and cleaning complete. (PWDSR.2013/14,
P.N.65,I.N.15)

Bd/M-13 P- a) 300 mm x 300 mm


386 (*)
(*) (Except that plain ceramic tiles of specified size and thickness shall
be used)
Bd/M-13 P- b) 300 mm x 200 mm
386 (*)
(*) (Except that plain ceramic tiles of specified size and thickness shall
be used)
PAGE NO : 65
16 Providing and fixing decorative ceramic tiles of size…… and above 5
to 6 mm thick for dado and skirting in requried position fixed on
plaster of cement mortar 1:4, neat cement paste, filling joints with neat
cement slurry, curing and cleaning complete. (PWDSR.2013/14,
P.N.66,I.N.16)

Bd/M-13 P- a) 300 mm x 300 mm


386 (*)
(*) (Except that decorative ceramic tiles of specified size and
thickness shall be used)
Bd/M-13 P- b) 300 mm x 200 mm
386 (*)
(*) (Except that decorative ceramic tiles of specified size and
thickness shall be used)
17 Providing and laying …… of size 25 cm x 25 cm of approved colour
and pattern and/or pattern for flooring with tiles of different colour and
design as directed with white and coloured marble chips upto the
maximum size of 6 mm/ 12 mm/ 20 mm for flooring in requried
position laid on a bed of cement mortar 1:4 including neat cement
float, filling joints with neat coloured cement slurry, curing, polishing
and rubbing complete with / without border.(PWDSR.2013/14,
P.N.66,I.N.17)

Bd/M-14 P- a) gray cement base marbal mosaic tile


386
Bd/M-14 P- b) white cement base marble mosaic galicha tile
386 (*)
(*) Except that white cement base marble mosaic galicha tiles shall be
used)
18 Providing and fixing ……. of size 25 cm x 25 cm of approved colour
and pattern and / or pattern with tiles of different colours and design as
directed, with white and coloured marbal chips upto the maximum
size of 6 mm/ 12mm/ 20mm, for dado and skirting in requried position
fixed on plaster of cement mortar 1:4 including neat cement float,
filling the joints with neat coloured cement slurry, curing, polishing
and rubbing complete with/ without border.(PWDSR.2013/14,
P.N.66,I.N.18)

Bd/M-15 P- a) gray cement base marble mosaic tile for dado and skirting
387
Bd/M-15 P- b) white cement base marble mosaic tiles galicha tiles for dado and
387 (*) skirting
(*) Except that white cement base marble mosaic galicha tiles shall be
used)
PAGE NO : 66
19 Bd/M-14 P- Providing and laying Terrazo tiled flooring 30 mm thick and 30 cm x
386 (*) 30 cm in plain / diamond pattern laid on a bed of cement mortar 1:4
including cement float, filling joints with neat cement slurry, curing,
polishing and cleaning complete. (PWDSR.2013/14, P.N.67,I.N.19)
(*) (Except that terrazo tiles shall be used)
20 Bd/M-16 P- Providing and laying white / coloured veined marble slab of 20 mm
387 thickness of of approved quality for flooring in requried pattern laid
on a bed of cement mortar 1:4 including neat cement float, filling
joints with neat coloured cement slurry, curing, polishing and cleaning
complete.(PWDSR.2013/14, P.N.67,I.N.20)

21 Bd/M-17 P- Providing and fixing white / coloured veined marble slab of 20 mm


387 thickness of approved quality for dado and skirting in requried pattern
fixed on plaster of cement mortar 1:4 including neat cement float,
filling joints with neat coloured cement slurry, curing, polishing and
cleaning complete.(PWDSR.2013/14, P.N.67,I.N.21)

22 Bd/M-18 P- Providing and laying in situ marble mosaic of 10 mm thickness for


387 flooring with white and coloured marble chips of upto 6 mm in size
coloured cement in suitable panels for flooring including on under
layer of cement concrete 1:2:4, Indian Patent Stone to form panels,
leveling, compaction, curing, polishing rubbing and cleaning
complete.(PWDSR.2013/14, P.N.67,I.N.22)
23 Bd/M-19 P- Providing and laying in situ marble mosaic of 10 mm thickness for
388 dado and skirting with white and coloured marble chpis of upto 6 mm
in coloured cement in suitable panels for dado and skirting including
under layer of cement concrete 1:2:4, Indian Patent Stone 40 mm
thick, providing aluminium strips to form panels, leveling,
compaction, curing, polishing rubbing and cleaning complete.
(PWDSR.2013/14, P.N.67,I.N.23)

PAGE NO : 67
24 Bd/M-21 P- providing and laying in requried position flooring of broken China
390 mosaic (broken pieces of China chips) of approved colour and pattern
laid on bed of cement mortar 1:4 including neat cement float, giving
proper slopes, compaction, curing and finishing etc. complete.
(PWDSR.2013/14, P.N.68,I.N.24)

25 Providing and laying ….. stone slabs 25 mm thickness for treads and
risers of steps and staircases with rounded nosing and grooves for the
treads laid on bed /plaster of cement mortar 1:4 including cement
float, filling joints with neat cement slurry, curing, polishing and
cleaning complete.(PWDSR.2013/14, P.N.68,I.N.25)

Bd/M-22 P- a) Polished Shahabad


390
Bd/M-22 P- b) Polished Tandur
390
Bd/M-22 P- c) Polished Kotah
390
26 Bd/M-26 P- Providing and laying white / colour veined marble slab 20 mm thick in
391 one piece stone slabs 25 mm thickness for treads and risers of steps
and staircases with rounded nosing and grooves for the treads laid on
bed / plaster of cement mortar 1:4 including cement float, filling joints
with neat cement slurry, curing, polishing and cleaning complete.
(PWDSR.2013/14, P.N.68,I.N.26)

27 Bd/M-22 P- Providing and laying Rough Shahabad stone slabs 40 mm to 50 mm


390 (*) thick for treads and risers of steps and staircases in one piece laid on
bed / plaster of cement mortar 1:4 including rounded nosing for the
treads, neat cement float, filling joints with white / coloured cement
slurry, curing, polishing and cleaning complete.(PWDSR.2013/14,
P.N.68,I.N.27)

(*) (Except that rough shahabad stone slab of specified thickness shall
be used)
PAGE NO : 68
28 Providing and laying ……. for treads and risers of steps and staircase
with nosing of treads moulded as per drawing or as directed laid on
bed / plaster of cement mortar 1:4 including cement float, filling joints
with neat cement slurry, cuing, polishing and cleaning complete.
(PWDSR.2013/14, P.N.69,I.N.28)

Bd/M-23 P- a) plain cement tiles


390
Bd/M-24 P- b) coloured cement tiles of approved colour shade
390
29 Providing and laying precast polished chequered …… for treads and
risers of steps and staircases with nosing and grooves for treads
moulded as per drawings or as directed laid on bed / plaster of cement
mortar 1:4 including cement float, filling joints with neat cement
slurry, curing, polishing and cleaning complete.(PWDSR.2013/14,
P.N.69,I.N.29)

Bd/M-33 P- a) plain cement tiles


392
Bd/M-33 P- b) coloured cement tiles
392
30 Providing and laying polished Chequered/…… for flooring in
required position laid on bed of cement mortar 1:4 including neat
cement float, filling joints with neat cement slurry, curing, polishing
and cleaning complete.(PWDSR.2013/14, P.N.69,I.N.30)
Bd/M-33 P- (a) a) plain cement tiles
392
Bd/M-33 P- (b) b) coloured cement tiles
392
31 Bd/M-35 P- Providing 25 to 30 mm thick partitions of both side polished black
393 (*) Kadappa stne of approved shape and quality and colour for urinals
including cutting holes of requried sizes in appropriate places to
receive pipes, fixing in the cement mortar 1:3, curing and cleaning
complete.(PWDSR.2013/14, P.N.69,I.N.31)

(*) (Except that black kadappa stone slab of specified size and
thickness shall be used)
PAGE NO : 69
32 Providing and fixing 2 mm thick P.V.C. flooring (vinyI flooring) of
approved shade and in approved pattern on smooth and levelled
surface complete as directed including all materials, pasting solution
of approved manufacture, P.V.C. flooring of reputed manufacturer
complete.(PWDSR.2013/14, P.N.70,I.N.32)

Spec: (As directed by Engineer in charge)


33 Providing and fixing kadappa stone slab for kitchen platform of
approved type and design 30 mm to 40 mm thick in cement mortar 1:4
including providing and fixing border patti on front edge, filling joints,
curing, cleaning etc. complete.(PWDSR.2013/14, P.N.70,I.N.33)

Spec: (As directed by Engineer in charge)


34 Bd/M-31 P- Providing and fixing in th carriageway interlocking concrete pavers
392 unishape (monolithic single layer precast concrete blocks) of gray
cement and of approved colour as per technical specification, .............
Having average crushing ....... placed on average thickness of 65 mm
uniformly graded river sand cushioning with properly compacted with
mechanical compactor with required level grade and camber etc.
complete as directed.(for carriageway only) (PWDSR.2013/14,
P.N.70,I.N.34)

Spec: (As directed by Engineer in charge)


a) 40 mm thick ....... Strength of 25 N/mm2
b) 60 mm thick ...... Strength of 35 N/mm2
35 Washing and Cleaning any kind of tiled flooring, dado with washing
powder and water.(PWDSR.2013/14, P.N.70,I.N.35)
Spec: (As directed by Engineer in charge)
36 Washing and cleaning natural surface of stone or any kind of marble.
(PWDSR.2013/14, P.N.70,I.N.36)
Spec: (As directed by Engineer in charge)
37 Machine polishing to cement/ marble mosaic tiled flooring or any
other type of flooring including cleaning, washing, etc. complete.
(PWDSR.2013/14, P.N.70,I.N.37)
Spec: (As directed by Engineer in charge)
38 Hand polishing to dado, skirting including cleaning, washing etc.
complete as directed.(PWDSR.2013/14, P.N.70,I.N.38)
Spec: (As directed by Engineer in charge)
39 Providing wax polishing to floors and dado, preparing the surface,
scaffolding etc. complete.(PWDSR.2013/14, P.N.70,I.N.39)
Spec: (As directed by Engineer in charge)
PAGE NO : 70
40 Removing the old cement concrete or any type of tiled flooring
including levelling the surface, cleaning the site including sorting out
serviceable tiles and stacking the same and debris disposing off upto a
distance of 50 metres.(PWDSR.2013/14, P.N.71,I.N.40)
Spec: (As directed by Engineer in charge)
41 Bd/M-12 P-385 (*) Providing and laying Rectified and vitrified mirror finish decorative
type tiles of size 600mm x 600 mm and 8 to 10 mm thick of approved
make, shade and pattern and having water absorption between 0.08 %
to 2.5 % for flooring in required position laid on a bed of 1:4 cement
mortar including neat cement float, filling joints with cement slurry,
curing and cleaning etc. complete. (PWDSR.2013/14, P.N.71,I.N.41)

(*) (Except that rectified and vitrified mirror finish decorative tiles of
specified size and thickness shall be used)
42 Bd/M-13 P-386 (*) Providing and fixing Rectified and vitrified mirror finish decorative
type tiles of size 600 mm x 600 mm and 8 to 10 mm thick of
approved make, shade and pattern and having water absorption
between 0.08 % to 2.5 % for dado in requried position laid on plaster
of 1:4 cement mortar, cement paste, filling joints with neat cement
slurry, curing and cleaning etc. complete.(PWDSR.2013/14,
P.N.71,I.N.42)

(*) (Except that rectified and vitrified mirror finish decorative tiles of
specified size and thickness shall be used)
43 Providing and laying C.I. Tiles in requried position of size 300 mm x
300 mm and 18 to 20 mm thick as per detail design and drawing
weighing approximate 5 kg. per one number of flooring on a bed of 40
mm thick 1:1 1/2:3, filling proportion with 1:1:2 cement concrete
including mixing hardening compound a the rate of one litre per one
bag of cement in cement concrete for bedding and for filling in the
proportion, finishing properly, curing and cleaning etc. complete as
directed by Engineet-in-charge. (PWDSR.2013/14, P.N.71,I.N.43)

Note : This item included only for Special Project Circle, Mumbai.
This item should not be use by any other Circle or Division.
PAGE NO : 71
44 Providing and laying Rectified and vitrified mirror finish decorative
type tiles of size …….. and 8 to 10 mm thick standard manufacturing
company of first quality (like Marbonite/ Possolona) of approved
make, shade and pattern for flooring in requried position laid on a bed
of 1:4 cement mortar including neat cement float, filling joints with
cement slurry, curing and cleaning etc. complete.(PWDSR.2013/14,
P.N.72,I.N.44)

Spec: (As directed by Engineer in charge)


a) 400 mm x 400 mm
b) 450 mm x 300 mm
c) 600 mm x 300 mm
45 Providing and laying Rectified and vitrified mirror finish decorative
type tiles of size 900 mm x 900 mm and 10 to 12 mm thick standard
manufacturing company of first quality (like Marbonite/ Possolona) of
approved make, shade and pattern for flooring in requried position laid
on a bed of 1:4 cement mortar including neat cement float, filling
joints with cement slurry, curing and cleaning etc. complete.
(PWDSR.2013/14, P.N.72,I.N.45)

Spec: (As directed by Engineer in charge)


Note: Prior approval of Superintending Engr. Shall be obtained for the
vitrified tiles of size 900 mm x 900 mm.
46 Providing and fixing Rectified and vitrified mirror finish decorative
type tiles of size …… and 8 to10 mm thick standard manufacturing
company first quality (like Marbonite / Possolona) of approved make,
shade and pattern for dado in requried position laid on plaster of 1:4
cement mortar, cement paste, filling joints with neat cement slurry,
curing and cleaning etc. complete. (PWDSR.2013/14, P.N.72,I.N.46)

Spec: (As directed by Engineer in charge)


a) 400 mm x 400 mm
b) 450 mm x 300 mm
c) 600 mm x 300 mm
PAGE NO:72
47 Providing and laying Rectified and vitrified mirror finish decorative
type tiles of size 900 mm x 900 mm and 8 to 10 mm thick standard
manufacturing company of first quality (like Marbonite / Possolona)
of approved make, shade and pattern for flooring in requried position
laid on a bed of 1:4 cement mortar, cement paste, filling joints with
neat cement slurry, curing and cleaning etc. complete.
(PWDSR.2013/14, P.N.73,I.N.47)

Spec: (As directed by Engineer in charge)


Note : Prior approvel of superintending Engr. Shall be obtained for the
vitrified tiles of size 900 mm x 900 mm.
48 Providing and laying Exterior grade fibrillated fiber reinforcement
heavy duty cement concrete tiles for Flooring of approved colour and
design 22 +2mm thick,Bayer colour pigmented as per IS: 1237-1980
reaffirmed in 2006, having compressive strength more than 500 kg/
cm2 like Ultra tiles or equivalent, in plain/desogmed [attrm pm a bed
of 1:6 cement mortor including cement float,filling joints with neat
cement slurry, curing, polished and cleaning complete. Good abrasion
resistance,Good impact resistance, Good Structural strength, Fade
resistance and skid resistance.(PWDSR.2013/14, P.N.73,I.N.48)

49 Providing and fixing Exterior grade fibrillated fiber reinforcement


heavy duty cement concrete tiles for Dado and skirting of approved
colour and design. 10+, -2 mm thick, Bayer colour pigmented as per
IS: 1237-1980 reaffirmed in 2006, applicable for wall tiles, like Ultra
tiles or equivalent, in plain / designed pattern in required postion fixed
on plaster of C.M 1:4 including cement float, filling joints wiht neat
colour cement slurry, curing polished and cleaning complete.
(PWDSR.2013/14, P.N.73,I.N.49)

Spec: (As directed by Engineer in charge)


50 Bd/m-31 P-392 Providing and fixing machine cut mirror polished green coloured
marble slab of required size and about 20 mm thick of approved
quality for boxing of windows, door frame of toilets on cement mortar
1:4 including neat cement float, filling joints, rounding and moulding
the edges, curing minor polishing rubbing and cleaning etc. complete.
(PWDSR.2013/14, P.N.73,I.N.50)

PAGE NO : 73
New Items
Note : The following all new items may be used on experimental basis for one year onl
51 Providing and fixing Aquaris RQ (Responsive) Or equivalent tiles /
sheet material for flooring having standard BS EN ISO 10874: 2012
and BS EN 649:2011 (Group-T) Compact homogenous materila,
usage for heavy foot traffic with special treatment have and RQ
protect having overall thickness 2.20 mm and wear layer thickness
2.00 mm having standard EN 429, ASTM F140 and weight as per
standard EN 430 (i.e.3000 g/m2) available sheet sizes as per EN 426
standard having width 2m and length 15/20 m covering surface area
30/40 m2 and available tiles size as per EN 427 standard 300mm
X300mm/500mmX500mm/610X610mm having special features of
abrasion resistnce as per EN 660-2 and ASTM D-3389 and slip
resistance as per DIN 51130,AS/NZS 4586 (wet pendulum), EN
13893 and ASTM D-2047; flexibility having standard EN 435 and
ASTM F-137, Sound insulation having standard EN ISO 717-2 having
Reaction to Fire as per EN ISO9239- 1:2010, EN ISO 11925-2:2010,
EN 13501-1:2007+A1:2009 and ASTM E648-06 standards having
thermal resistance ISO 8320(EB 12664) and ASTM 1415 and Fungal
and bacteria. Resistance as per standard (E1) PCP, ASTM G-21,
ASTM D-3273 Clean room (ASTM F51/68) including maritime usage
th product should be with ISI Marking and IMO RES A653(16),IMO
MSC61(67). Work shall be executed by certified applicator only and
work shall be guaranteed for 5 years and guarantee shall be provided
on Rs. 500/- stamp paper.(PWDSR.2013/14, P.N.74,I.N.51).
(PWDSR.2013/14, P.N.74,I.N.51)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of Superintending Engineer.
PAGE NO : 74
52 Providing and fixing Spica RQ (Responsive) Or equivalent tiles /
sheet material for flooring having standard BS EN ISO 10874: 2012
and BS EN 649:2011(Group-T) Non-directional homogeneous
material, usage for heavy foot traffic/Heavy duty wiht special
treatment have RQ protect no wax no polish for life, having overall
thickness is 2.00 mm having standard EN 428 with wear layer 2.00
mm having standard EN 429, ASTM F410 and weight as per standard
EN 430 (i.e. 2950 gm /m2) available sheet sizes as per EN 426
standard having width 2m and length 15/20 m covering surface area
30/40 m2 and available tiles size as per EN 427 standard
300mmX300mm/500mm x500mm/610X610 mm having special
features of abrasion resistance as per EN 660-2 and ASTM D- 3389
and slip resistance as per DIN 51130, AS/NZS 4586 (wet pendulum)
EN 13893 and ASTMD 2047; dimensional stability EN 434 having
flexibility standard EN 435 astm f- 137, having reactopm tp fore EM
OSP 9239-1: 2010 ,EN ISO 11925-2: 2010,EN 13501-1-
2007+A1:2009ASTM E 648-06;0Sound insulation having standard
EN ISO 717-2 having stain and chemical resistance ASTM F- 925, BS
EN ISO 26987-2012 including Fimga; amd bacteroa resostamce as per
standard ASTMG-21, ASTM D-3273 and (E1)PCP; Clean rooms as
per standard ASTM F51/63; The product should be with ISI Marking
and IMO RES A653 (16), IMO MSC 61 (67). Work shall be executed
by certified applicator only and work shall be guaranteed for 3 years
and guarantee shall be provided on Rs. 500/- stamp paper.
(PWDSR.2013/14, P.N.75,I.N.52)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of
Superintending Engineer..
PAGE NO : 75
53 Providing and fixing Vega Plus (Responsive) Or equivalent (For
Hospitals /Clties) sheet material for flooring having standard BS EN
ISO 10874: 2012 and BS EN 649:2011 (Group-P) Dissipative
homogeneous flooring material with usage for medium to heavy foot
traffic having overall thickness 2.00 mm as per EN 428 standard with
thickness of wear layer 2.00 mm as per standard EN 429, ASTM F
410 and weights as per standard EN 430 (i.e. 3400gm/,2) available
sheet sizes as per EN 426 standard having width 2.00m and length
15/20 m covering surface are 30/40 m2 and available tiles size as per
standard EN 427 including sizes
300mmX300mm/500mmX500mm/610mmX610mm having special
features of abrasion resistance as per EN 660-2 and ASTM D-3389
and slip resistance as per DIN 51130, AS/NZS 4586 and ASTM D-
2047; having dimensional stability EN 434, Flexibility EN 435 and
ASTM F-137 Castor Chair test as per stamdard EN 425 use of chair
continuous; Sound insulation having standard EN ISO 717-2;
Reaction to fire EN ISO 9239-1: 2010, EN ISO- 11925-2:2010, EN-
13501-1-2007+A1:2009,ASTM E648-06; Stain and chemical
resistance ASTM F-925, BS EN ISO 26987: 2012 including Fungi and
bacteria resistance As per standard (E1) PCP, ASTMG-21,ASTM-
F51768; Clean rooms as per standard ASTM F 51/68 etc. The product
should be with ISI Marking and IMO RES A 653 (16), IMO MSC 61
(67).Work shall be executed by certified applicator only and work
shall be guaranteed for 3 years and guarantee shall be provided on Rs.
500/- stamp paper.(PWDSR.2013/14, P.N.76,I.N.53)

Spec: (As directed by Engineer in charge)


PAGE NO : 76
54 Providing and fixing Canopus plus (Responsive)Or equivalent
(ForKitchen and Bath antiskid tiles) sheet material for flooring having
standard BS EN ISO 10874:2012 and BS EN 649:2011(Group-T)
Safety and anti-slip vinyl material usage for heavy foot traffic special
treatment Anti-slip surface with silicon carbide granules with overall
thickness 2.00 mm as per standard EN 428 with thickness of wear
layer 1.00 having standard EN 429, ASTM F-410 and weight as per
standard EN 430 (i.e. .3400gm/m2) available sheet sizes as per EN
426 standard having width 2m and length 15/20 m covering surface
are 30/40 m2 and available tiles size as per standard EN427 including
sizes 300mmX300mm/ 500mmx500mm/ 610mmX610mm having
special features of abrasion resistance as per EN 660-2 and ASTM D-
3389 and slip resistance as per DIN 51130, BS 7976-2 (Pendulum
method), EN 13893, ASTM D-2047; Dimensinal stability EN 434;
Flexibility EN 435 ASTM F 137 and Castor chair test EN 425 use of
chair continuous, Sound insulation EN ISO 717-2. Stain and chemical
resistance BS EN ISO 26987:2012, ASTM F-925, Fungi and bacteria
resistance As per standard (E1) PCP, ASTMG-21, ASTM-F51768; The
product should be with ISI Marking and IMO RES A 653 (16), IMO
MSC 61 (67). Work shall be executed by certified applicator only and
work shall be guaranteed for 3 years and guarantee shall be provided
on Rs. 500/- stamp paper.(PWDSR.2013/14, P.N.77,I.N.54)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of
Superintending Engineer.
PAGE NO : 77
55 Providing and fixing Polaris 4.50 MM (Responsive) Or equivalent
(For Sports and Gymnasium) sheet material for sports flooring,
friction, shock absorption, vertical deformation, resistance to rolling
load, vertical ball behaviour, having standard BS EN 14 904:2009,
special treatment having PUR: no wax no polish, sunCleanTM, glass
fibre grid reinforcement, high density compact foam. having overall
thickness 4.50 mm as oer stabdard EN 428, including weight 3100.00
g/m2 as per standard EN 430, with available sheet sizes as per EN 426
standard having width 1.5m length 10m covering surface are 15m2
and available tiles covering surface are 15m2 and available tiles size
as per standard EN 429, ASTM F-410including sizes (0.50(Polaris
Punch) 1.5 (PolarisFootwork). Including technical Characteristics BS
EN 14 904 having friction 89 (pass), shock absorption P2(pass),
vertical deformation P2 (pass), vertical ball behaviour 98 (pass)
resistance to rolling load (pass), resistance to wear 28241 (pass),
specular reflectance42 %, specular glass 17(pass), Resistance to
indention 0.23 (pass), Classification having Reaction to Fireas per EN
13501-1: 2007+A1:2009 and special treatment PUR: no wax no
polish, sunCleanTM. The product should be with ISI Marking and
IMO RES A 653 (16), IMO MSC 61 (67). Work shall be executed by
certified applicator only and work shall be guaranteed for 3 years and
guarantee shall be provided on Rs. 500/- stamp paper..
(PWDSR.2013/14, P.N.78,I.N.55)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of
Superintending Engineer.
PAGE NO : 78
55 Providing and fixing Natural Wood Pllanks (Responsive) Or
equivalent having standards BS EN ISO 10874:2012,BS EN 649:2011
(Group-T) Vinyl wood planks material for Heavy foot Traffic; Special
treatment having PUR: no wax no polish, overall thickness (1.50 mm )
as per En 428 standards including Thickness of wear layer having
standard EN 429, ASTM F 410 0.20MM, with available sheet sizes as
per standard EN 427, EN 430, having Tile Size 2700/3400, 6X36,
given units g/m2, inch x inch having special features of abrasion
resistance as per EN 660-2,ASTM D 3389 (Weight loss/1000cycles),
slip resistance DIN 51130, EN 13893, ASTM D 2047 and
Dimensional stabo;otu EM 434, Castor Chair test as per standard EN
425 use of chair continuous; and Stain and chemical resistance BS EN
ISO 26987:2012, ASTM F-925, Fungi and bacteria resistance As per
standard (E1) PCP, ASTMG-21, ASTM-F51768; The product should
be with ISI Marking and IMO RES A 653 (16), IMO MSC 61 (67).
Work shall be executed by certified applicator only and work shall be
guaranteed for 2 years and guarantee shall be provided on Rs. 500/-
stamp paper.(PWDSR.2013/14, P.N.79,I.N.55)
Spec: (As directed by Engineer in charge)
Note: The item should be executed with prior approval of
Superntending Engineer.
PAGE NO : 79
BD-N : WOOD FINISHES
1 Bd/N-1.2 P- Providing and applying Wax polishing to the new wood work
399 including knotting, preparing the surface, scaffolding etc. complete as
directed.(PWDSR.2013/14, P.N.81,I.N.1)
2 Bd/N-1.2 P- Providing and applying Wax polishing to the old wood work including
399 knotting, preparing the surface, scaffolding etc. complete as directed.
(PWDSR.2013/14, P.N.81,I.N.2)
3 Bd/N-1.3 P- Providing and applying french polishing for requried finish on
399 previously polished wood including knotting, preparing the surface,
scaffolding etc. complete as directed.(PWDSR.2013/14, P.N.81,I.N.3)

4 Bd/N-1.3 P- Providing and applying french polishing to new wood work including
399 knooting, preparing the surface, scaffoldinng etc. complete as directed.
(PWDSR.2013/14, P.N.81,I.N.4)
5 Bd/ N-1.4 P- Providing and applying varnish in one coat on previously varnished
400 wood work including knotting, preparing the surface, scaffolding
etc.complete.(PWDSR.2013/14, P.N.81,I.N.5)
6 Bd/N-1.6 P- Providing and applying coal tar in coat on previously coal tarred wood
400 including preparing the surface, scaffolding etc. complete.
(PWDSR.2013/14, P.N.81,I.N.6)
7 Bd/N-1.6 P- Providing and applying coal tar in two coats on new wood work
400 including preparing the surface, scaffolding etc.complete.
(PWDSR.2013/14, P.N.81,I.N.7)
8 Providing and applying Malamine polish of requried finish to
woodwork by spray machine including knotting and preparing the
surface by scrapping, applying french polishing, scaffolding if
requried etc. complete.(PWDSR.2013/14, P.N.81,I.N.8)
Spec: (As directed by Engineer in charge)
PAGE NO : 81
BD-O : OIL PAINTING
1 Providing and applying two coats of aluminium paint of approved
make to new structural steel work in building and workshops
including scaffolding if necessary, cleaning and preparing surfaces by
solvent, degreasing and derusting by manual scraping / mechanically
by sand blasting / flame cleaning / by chemical methods complete
(excluding primer coat).(PWDSR.2013/14, P.N.83,I.N.1)
2 Providing and applying ….. Of synthetic enamel paint of approved
colour to new/old structural steel work and wood work in building and
workshops including scaffolding if necessary, cleaning and preparing
surface by solvent, degreasing and derusting by manual
scraping/mechanically by sand blasting/shot blasting flame
cleaning/by chemical methods complete.(excluding primer coat).
(PWDSR.2013/14, P.N.83,I.N.2)

Bd/O-5 P-405 a) one coat


Bd/O-5 P-405 b) two coats
3 Providing and applying …. Coats of flat oil paint of approved colour
and shade to the old/new steel work and iron work (previously
painted) in building and workshops including scaffolding if necessary,
cleaning and preparing surfaces by solvent, degreasing and derusting
by manual scraping/mechanically by sand blasting/shot blasting flame
cleaning/by chemical methods complete. (excluding primer coat).
(PWDSR.2013/14, P.N.83,I.N.3)

Bd/O-6 P-406 a) one coat


Bd/O-6 P-406 b) two coats
4 Providing and applying ….. Coats of flat oil paint of approved colour
and shade to the plastered surface in buildings and workshops
including scaffolding if necessary, cleaning the surface and preparing
surface etc. complete.(excluding primer coat). (PWDSR.2013/14,
P.N.83,I.N.4)

Bd/O-7 P-406 a) one coat


Bd/O-7 P-406 b) two coats
Bd/O-7 P-406 c) two coats (exterior quality)
PAGE NO : 83
5 Providing and applying ….. Coats of waterproof cement paint of
approved manufactures and of approved colour to the plastered
surface including scaffolding, if necessary preparing the surfaces,
watering for two days complete.(PWDSR.2013/14, P.N.84,I.N.5)
Bd/O-8 P-406 a) two coats
Bd/O-8 P-406 b) three coats
6 Providing and applying one coat of seal cement primer of approved
manufacturer and shade including scaffolding if necessary, cleaning
the surfaces etc. complete.(PWDSR.2013/14, P.N.84,I.N.6)
Spec: (As directed by Engineer in charge)
7 Providing and applying one priming coat…… including preparing of
the surface by thoroughly cleaning oil, grease, dirt and other foreign
matter with wire brushing, fine fire steel wool, and sand paper,
scaffolding etc. complete.(PWDSR.2013/14, P.N.84,I.N.7)
Spec: (As directed by Engineer in charge)
a) over steel and other metal surfaces
b) to wood and wood based surface
c) on concrete/ masonry / Asbestos cement/ plastered surfaces
8 Removing old paint from steel and other metal surface and making the
surface even with hand scrapping or by mechanical means scaffolding
necessary etc. complete.(PWDSR.2013/14, P.N.84,I.N.8)

Spec: (As directed by Engineer in charge)


Note : Following items should not be operated without specific.
Permission from the superintending Engineer.
9 Providing and applying three coats of …… of approved colour to …..
In building and workshops including scaffolding if necessary,
claeaning and preparing surface by solvent, degreasing and derusting
by manual scraping/mechanically by sand blasting/shot blasting, flame
cleaning/ by chemical methods complete.(excluding primer coat).
(PWDSR.2013/14, P.N.84,I.N.9)

Bd/O-5 P-405 a) synthetic enamel paint…. new structural steel work and wood work

Bd/O-5 P-405 b) flat oil paint….. new steel work and iron work
PAGE NO : 84
10 Providing and applying three coats of flat oil paint of approved colour
and shade to the plastered surface in building and workshops
including scaffolding if necessary, cleaning the surface and preparing
surface etc. complete.(excluding primer coat).(PWDSR.2013/14,
P.N.85,I.N.10)

Spec: (As directed by Engineer in charge)


Note : Following items should not be operated without specific
permission from the superintending Engineer.
11 Providing and applying one pre-treatment coat for Acrylic latex paint
of approved manufacturer including preparing the surface etc.
complete.(PWDSR.2013/14, P.N.85,I.N.11)
12 Providing and applying one coat of exterior primer for Acrylic latex
paint of approved manufacturer including preparing the surface etc.
complete.(PWDSR.2013/14, P.N.85,I.N.12)
13 Providing and applying two coats of exterior Acrylic latex paint of
approved colour and shade to the plastered surface as per
manufacturers specification including scaffolding preparing the
surface etc.complete. (Excluding primer coat). (PWDSR.2013/14,
P.N.85,I.N.13)

PAGE NO : 85
BD-P : COLOUR WASHING, WHITE WASHING AND DISTEMP
1 Providing and applying washable distemper of approved quality,
colour and shade to old / new surfaces in ...... Including scaffolding,
preparing the surfaces to receive the paint and applying putty
(excluding priming coat) complete.(PWDSR.2013/14, P.N.87,I.N.1)

Bd/P-4 P-413 a) one coat


Bd/P-4 P-413 b) two coats
2 Providing and applying washable oil-bound distemper of approved
quality colour and shade to old/new surfaces in..... Including
scaffolding, preparing th surfaces to receive the paint and applying
putty (excluding priming coat) complete.(PWDSR.2013/14,
P.N.87,I.N.2)

Bd/P-5 P-413 a) one coat


Bd/P-5 P-413 b) two coats
3 Bd/P-6 P-414 Providing and applying morning glory Acial Paints or equivalent
plastic emulsion paint of approved quality colour and shade to old/new
surfaces in two coats including scaffolding, preparing the surfaces to
receive th paint and applying putty(excluding priming coat) complete.
(PWDSR.2013/14, P.N.87,I.N.3)

4 Scrapping the old plastered internal surface with sand paper and
coating th entire surface with mixture of whiting or glue and linseed
oil including scaffolding etc. Complete as directed. (PWDSR.2013/14,
P.N.87,I.N.4)
Spec: (As directed by Engineer in charge)
Note: Following items should not be operated without specific permission from the Sup
5 Providing and applying ... In three coats to old/ new plastered or
masonry surfaces and asbestos cement sheets including scaffolding
and preparing the surface to receive the paint by brushing and
brooming down and applying putty etc. complete . (PWDSR.2013/14,
P.N.87,I.N.5)

Bd/P-2 P-412 b) colour-wash


Bd/P-5 P-413 c) washable oil-bound distemper
New Items
Note: The following new item may be used on experimental basis for
one year only.
6 Providing sand face plaster externally to concrete, stone or brick
surfaces using approved screened sand including preparing the base,
watering and applying base coat of 15 mm thick in cement mortar 1:4
using Supercorn-100 as melamine based super plastizer 1% by weight
of cement, krifib synthetic fibre a additions at 125 gm per bag of
cement and sufumex-100D of Krishna Conchem Products i.e. Natural
Amorophous microselliceours admixture @ 2% by weight of cement
curing the same for not less than two days and keeping the surface of
base coat rough to receive the sand faced treatment not to exceed 8
mm thickness in cement mortar 1:4 and finishing the surface by taking
out grains and curing for 14 days and scaffolding etc. complete.
(PWDSR.2013/14, P.N.88,I.N.6)

Spec: (As directed by Engineer in charge)


BD-Q : WOOD WORK
1 Providing and fixing country teak wood planking …… for flooring
planed on both sides, tongued and grooved including scaffolding if
necessary and coat of primer complete. (PWDSR.2013/14,
P.N.89,I.N.1)
Bd/Q-1 P-419 a) 25 mm thick
Bd/Q-1 P-419 b) 50 mm thick
2 Providing and fixing ….. joists and girders in timber floors of single,
double or framed type including scaffolding if necessary and one
primer coat complete.(PWDSR.2013/14, P.N.89,I.N.2)
Bd/Q-2 P-420 a) country teak wood
Bd/Q-2 P-420 b) hard wood of approved species
3 Bd/Q-3 P-421 Providing and fixing country teak wood plank ceiling 20 mm thick
planed on the underside, tongued and grooved including iron screws
and scaffolding if necessary, including primer coat on underside and
one coat of coal tar on upper side complete. (PWDSR.2012/13,
P.N.89,I.N.3)

4 Providing and fixing ….. framed collar beam / king post / queen post
truss with all iron work including scaffolding if necessary and primer
coat complete.(PWDSR.2013/14, P.N.89,I.N.4)
Bd/Q-4 P-422 a) country teak wood
Bd/Q-4 P-422 b) hard wood of approved species
5 Bd/Q-5 P-423 Providing and fixing country teak wood common rafters, purlins and
purlin cleats, hip rafters, jack rafters, ridges, wall plates,post plates
and posts for roofing etc. including scaffolding if necessary, all iron
work and one primer coat complete.(PWDSR.2013/14, P.N.89,I.N.5)

PAGE NO : 89
6 Providing and fixing ….. two way trellis work with battens or laths 2.5
cm x 1.2 cm and 5 cm x 5 cm opening including frame of 8 cm x 5 cm
vertical and horizontal scantling and cost of primer complete.
(PWDSR.2013/14, P.N.90,I.N.6)
Bd/Q-6 P-424 a) country teak wood
Bd/Q-6 P-424 b) hard wood of approved species
7 Bd/Q-8 P-425 Providing and constructing country teak wood hand rail of 60 x 70
mm as per detailed drawings or as directed by the Engineer-in-charge
including French polishing complete.(PWDSR.2013/14, P.N.90,I.N.7)

8 Bd/Q-8 P-425 Providing and fixing in position P.V.C. hand rail of approved quality,
make and shade including mild steel plate of requried size as directed
etc. complete.(PWDSR.2013/14, P.N.90,I.N.8)
9 Providing and fixing 20 mm thick teak wood particle board faced
with….. of 150 to 200 mm wide to door or window frames including
20 mm diameter aluminium curtain rod with sockets and finishing
with french polishing (without top) complete. (PWDSR.2013/14,
P.N.90,I.N.9)

Bd/Q-11 P-427 a) teak wood Veneer for pelmet boxes

Bd/Q-11 P-427 b) laminate sheet of approved shade for pelmet box


10 Bd/Q-12 P-428 Providing and fixing hard wood of approved species picture rail 25 x
35 cm moulded as per drawings or as directed by the Engineer,
securing to the wall surface after plastering is done including finishing
with one coat of primer etc.complete. (PWDSR.2013/14,
P.N.90,I.N.10)

11 Bd/Q-13 P-428 Providing and fixing wooden shelf of 25 mm thick hard wood plank
30 cm wide with jungle wood brackets of 45 x 35 mm at 1.2 metre
centre to centre without fillet including primer coat complete.
(PWDSR.2013/14, P.N.90,I.N.11)
PAGE NO : 90
12 Bd/Q-18 P-431 Providing and fixing decorative teak plywood veneer lining 4 mm
thick with backing of country teak wood frame work of battens 12 x
25 mm at 30 cm centre to centre fixed to walls and pillars without
skirting and cornice as per drawings including necessary iron work
and finishing the exposed wood with french polish complete.
(PWDSR.2013/14, P.N.91,I.N.12)

13 Bd/Q-18 P-431 Providing and fixing decorative teak plywood Veneer lining 4 mm
thick on existing framework fixed to walls and pillar of battens 12 x
25 mm at 30 cm centre to centre without skirting and cornice as per
drawings including necessary iron work and finishing the exposed
surface with french polish complete.(PWDSR.2013/14, P.N.91,I.N.13)

14 Providing and fixing ….. eaves board 15 cm wide and 25 mm thick


plain type including scaffolding and primer one coat complete.
(PWDSR.2013/14, P.N.91,I.N.14)
Bd/Q-19 P-432 a) country teak wood

Bd/Q-19 P-432 b) hard wood of approved species

15 Providing and fixing ….. barge board 22 cm wide and 20 mm thick


plain type including scaffolding and primer one coat complete.
(PWDSR.2013/14, P.N.91,I.N.15)
Bd/Q-21 P-433 a) country teak wood

Bd/Q-21 P-433 b) hard wood of approved species

16 Providing and fixing teak wood stair case 910 mm (3'-0") wide clear
including teak wood stringers 350 x 76 mm (14" x 3"), teak wood
risers 150 x 20 mm (6" x 3/4"), teak wood treads 300 x 25 mm (12" x
1)" with nosing including iron fixtures and fastenungs and applying
one coat of primer etc. complete. (PWDSR.2013/14, P.N.91,I.N.16)

Spec: (As directed by Engineer in charge)


PAGE NO : 91
17 Providing and fixing shutter to wall cupboard made from 12 mm thick
teak wood particle board one face with approved colour laminated
face bonded with phenol formaidehyde synthetic resin B.W.P. grade
including lipping, beading, iron oxidised fixtures and fastenings and
painting primer one coat etc. copmplete.(PWDSR.2013/14,
P.N.92,I.N.17)

Spec: (As directed by Engineer in charge)


18 Bd/ W-8 P-587 Removing the existing floor planking carefully and stacking the same
in the compound as directed.(PWDSR.2013/14, P.N.92,I.N.18)
19 Bd/ W-8 P-587 Removing and lowering down ceiling from roof carefully and stacking
the same in the compound as directed.(PWDSR.2013/14,
P.N.92,I.N.19)
New Items
Note: The following new item may be used on experimental basis for
one year only.
20 Providing and fixing shutter to wall cupboard of size low height/full
height made from 19 mm thick Marine Plywood with one side
laminated (1.5 to 2.00 mm thick ) of approved colour and shade
including lipping, beading, powder coated/chromium plate) fixtures
and fastening, primer and two coats of oil painting of inner side,
French polishing for lipping and beading etc. complete.
(PWDSR.2013/14, P.N.92,I.N.20)

Spec: (As directed by Engineer in charge)


PAGE NO : 92
BD-R : ROOFING AND CEILING
1 Bd/R-1 P-449 Providing and fixing Manglore tiled roofing with class "AA" tiles
including securing the last course of tiles near the eaves with steel flats
of 40 mm x 3 mm and 1.22 mm wire, fixing 50 x 25 mm horizontal
teak wood battens, all iron work and oiling the battens and planing the
underside of battens complete. (excluding ridge and hip tiles).
(PWDSR.2013/14, P.N.93,I.N.1)

2 Bd/R-2 P-450 Providing and fixing Manglore tiled roofing with "AA" tiles including
securing the last course of tiles near the eaves with steel flats of 40
mm x 3 mm and 1.22 mm wire, fixing of 25 mm x 12 mm country
teak wood sloping battens and fixing 50 mm x 25 mm country teak
wood horizontal battens over the sloping battens, all iron work and
coaltarring the battens and planning the undersides and battens
complete. (excluding ridge and hip tiles).(PWDSR.2013/14,
P.N.93,I.N.2)

3 Bd/R-3 P-450 Providing and fixing Manglore type ridge and hip tiles class "AA"
tiles including scaffolding if necessary, pointing with coloured cement
mortar and curing complete.(PWDSR.2013/14, P.N.93,I.N.3)
4 Bd/R-5 P-452 Providing and fixing corrugated galvanised iron sheets of 0.80 mm
thickness (22 B.W.G.) for roofing without wind ties including
fastening with galvanised iron screws and bolts and bitumen washers
as per drawings complete.(PWDSR.2012/13, P.N.93,I.N.4)
5 Bd/R-5 P-453 Providing and fixing plain zinc sheeting of 1.00 mm thickness (20
B.W.G.) over the ridge, hip or valley for galvanised corrugated iron
sheet roofing including fastering with galvanised iron screws and bolts
and bitumen washer complete.(PWDSR.2013/14, P.N.93,I.N.5)
6 Bd/R-7 P-453 Providing and fixing 6.00 mm thick asbestos cement corrugated sheet
roofing including galvanised iron J or L hook bolts, galvanised iron
and bituminous washers, galvanised iron cramp bolts, nuts and
scaffolding complete.(PWDSR.2013/14, P.N.93,I.N.6)
7 Bd/R-8 P-454 Providing and fixing 6.00 mm thick asbestos cement semi- corrugated
sheet roofing including galvanised iron J or L hook bolts, galvanised
iron and bituminous washers, galvanised iron cramp bolts, nuts and
scaffolding complete.(PWDSR.2013/14, P.N.93,I.N.7)
PAGE NO : 93
8 Bd/R-9 P-455 Providing and fixing 6 mm thick asbestos cement ridge capping for
roofing including galvanised iron book bolts and galvanised iron and
bituminous washers, galvanised iron cramp bolts and nuts etc.
complete.(PWDSR.2013/14, P.N.94,I.N.8)
9 Providing and fixing valley gutter of 0.80 mm thickness (22 B.W.G.)
plain galvanised iron sheets…..with country teak wood planking 20
mm thick including two coats of coal tarring the upper surface of
plank (excluding painting to under side of plank).(PWDSR.2013/14,
P.N.94,I.N.9)

Bd/R-10 P-455 a) 120 cm wide

Bd/R-10 P-455 b) 90 cm wide

10 Bd/R-11 P-456 Providing and fixing glass tiles of Manglore type at requried places in
Manglore tile roof including scaffolding, if necessary.
(PWDSR.2013/14, P.N.94,I.N.10)
FALSE CEILING
11 Providing and fixing false ceiling of …… including scaffolding if
necessary, all iron work etc. complete. (excluding frame work and teak
wood runner).(PWDSR.2013/14, P.N.94,I.N.11)
Bd/R-16 P-460 a) plain asbestos cement sheets 4 mm thick

Bd/R-17 P-461 b) teak wood particle board half perforated sheets 12 mm thick

12 Bd/R-18 P-461 Providing and fixing false ceiling of 15 to 20 mm thick decorative


boards of fibrous plaster of paris including scaffolding if necessary, all
architectural work like mouldings, cornices, coves, domes, cups as per
detailed drawings and three coats of spray painting to boards etc.
complete. (excluding frame work, runners and mild steel suspenders).
(PWDSR.2013/14, P.N.94,I.N.12)

MISCELLANEOUS ITEMS
13 Providing and dammering to roof with two coats of bitumen on new
dungree cloth one coat on each side etc. complete as directed.
(PWDSR.2013/14, P.N.94,I.N.13)
Spec: (As directed by Engineer in charge)
14 Providing and dammering to roof with one coat of bitumen (without
cloth) including scaffolding etc. complete as directed.
(PWDSR.2013/14, P.N.94,I.N.14)
Spec: (As directed by Engineer in charge)
PAGE NO : 94
15 Bd/W-8 P-587 Removing and resetting Manglore tiled roof including refixing loose
battens complete.(PWDSR.2013/14, P.N.95,I.N.15)
16 Bd/W-8 P-587 Removing the tiles, battens and dungry cloth from roof, sorting out the
serviceable and unserviceable materials and stacking the same as and
where directed in the compound, scaffolding etc. complete.
(PWDSR.2013/14, P.N.95,I.N.16)
17 Bd/W-8 P-587 Removing the tiles, battens, dungry cloth, purlins, rafters, ridges etc
from roof, sorting out the serviceable and unserviceable materials and
stacking the same as and where directed in the compound, scaffolding
etc. complete.(PWDSR.2013/14, P.N.95,I.N.17)
18 Bd/W-8 P-587 Removing galvanised iron or asbestos cement sheet roof covering and
stacking the same as and where directed in the compound, scaffolding
etc. complete.(PWDSR.2013/14, P.N.5,I.N.18)
19 Bd/W-8 P-587 Removing galvanised iron or asbestos cement sheet roofing including
purlins, principal rafters, etc. including sorting out the serviceable and
unserviceable materials and stacking the same as and where directed
in the compound, including scaffolding etc. complete.
(PWDSR.2013/14, P.N.95,I.N.19)

20 Bd/W-8 P-587 Removing and lowering down the roof truss carefully without
damaging the members and stacking the same as and where directed in
the compound, including scaffolding etc. complete.(PWDSR.2013/14,
P.N.95,I.N.20)
21 Bd/W-8 P-587 Removing R.S. girders of any size and span, lowering the same and
stacking the same as and where directed in the compound, including
scaffolding etc. complete.(PWDSR.2013/14, P.N.95,I.N.21)
22 Providing and fixing country cut teak wood battens …. for Manglore
tiled roof work with all iron works, scaffolding etc. complete.
(PWDSR.2013/14, P.N.95,I.N.22)
Spec: (As directed by Engineer in charge)
a) 50 mm x 25 mm
b) 25 mm x 12 mm
23 Providing and fixing New Manglore tiles with class "AA" tiles
including scaffolding etc. complete.(PWDSR.2013/14, P.N.95,I.N.23)

Spec: (As directed by Engineer in charge)


PAGE NO : 95
24 Providing and fixing frame work of alluminium sections for
suspended false ceiling consisting of alluminium T 2" x 1 1/2" (50 mm
x 40 mm) weighing 0.39 kg/m at 60 cms c/c & fixed with 1/2" x 1/2"
(15 x 15 mm) flanges weighing 0.119 kg/m suspended on 6 mm dia.
mild steel rod weighing 0.22 kg/m, fixed on wall and beams including
rounding of the edges with alluminium T of 2" x 1 1/2" (50 mm x 40
mm) weighing 0.39 kg/m etc. (all alluminium sections shall be
anodised) including all labour etc. complete.(PWDSR.2013/14,
P.N.96,I.N.24)

Spec: (As directed by Engineer in charge)


25 Providing and fixing frame work of galvanised iron suspended false
ceiling which includes galvanised iron perimeter channels of size 27
mm and 0.5 mm thick having one flange of 20 mm and another flange
of 30 mm along with perimeter of the ceiling fixing in brick wall /
partition with the help of rawal plugs and screws, suspending
galvanised iron intermediate channels of size 45 mm and 0.9 mm thick
with two flanger of 15 mm each from the soffit at 1200 mm centres
with steel galvanised iron hanger of width 25 mm x 0.5 mm fasteners.
Ceiling section of 0.5 mm thickness having curved edge of 51.5 mm
and two flanges of 26 mm each with lips of 10.5 mm than fixed to the
intermediate channel with the help of connecting clips and in direction
perpendicular to the intermediate channel at 450 mm centre to centre
12.5 mm dry wall screws at 230 mm centres; Screw fixing is to be
done mechanically either with screw driver or drilling machine with
suitable attachment.(PWDSR.2013/14, P.N.96,I.N.25)

Spec: (As directed by Engineer in charge)


26 Providing and fixing 22 BWG Plain G.I. sheet on top of plank ceiling
of M.T. roof portion of requried size using screws to make roof good
water tight etc. complete.(PWDSR.2013/14, P.N.96,I.N.26)
Spec: (As directed by Engineer in charge)
27 Providing and fixing 22 BWG Plain G.I. sheet 0.40 metre wide on top
of sloping C.C. chamfering of size 25 cm x 25 cm over Manglore Tile
Roof at the joint of Brick Masonry wall, including cutting groove in
the masonry wall upto 25 mm deep and filling the joints with cement
mortar to make it water tight including scaffolding etc. complete.
(PWDSR.2013/14, P.N.96,I.N.27)

Spec: (As directed by Engineer in charge)


PAGE NO : 96
28 Providing and fixing 22 BWG Plain G.I. Sheet 0.40 metre wide on top
of sloping C.C. chamfering of size 25 cm x 25 cm over Manglore Tile
Roof at the joint of stone Masonry Wall, including cutting groove in
the masonry wall upto 25 mm to 50 mm deep and filling the joints
with cement mortar to make it water tight including scaffolding etc.
complete.(PWDSR.2013/14, P.N.97,I.N.28)

Spec: (As directed by Engineer in charge)


29 Providing and fixing corrugated precoated galvanized iron sheet
roofing having thickness 0.80 mm along with necessary accessories
like self drilling and tapping screws with weather cap, self drilling and
tapping screws EPDM with weather cap for flush at both side
including ridge 300 x 300 mm x 0.80 mm thick with all leads and lifts
scaffolding etc. complete.(PWDSR.2013/14, P.N.97,I.N.29)

Spec: (As directed by Engineer in charge)


30 Providing and fixing in position Gypsum board false ceiling with 12.5
mm thick Gypsum boards, screwed / fixed to the under structure of
suspended G.I. Grid constructed and suspended from the main ceiling
consisting of ceiling sections of size 25 x 50 mm maximum centre to
centre distance of 600 milimetre perimeter channel and intermediate
channels at maximum centre to centre distance 1200 milimetre
galvanized grid should be fixed to reinforced cement concrete slab.
The gypsum board should be fixed to galvanized iron grid with
necessary screws. The boards should be taped and filled from
underside to give smooth, seamless ceiling. The rate should include
necessary additional ceiling sections and intermediate channels.
Additional intermediate channels should be fixed to strap hangers for
additional support to prevent strapping at every 1200 milimetre item to
be completed in all respect including necessary sleeves for ducts
finishing of joints cut outs and including labour, material, lifts etc. all
complete.(PWDSR.2013/14, P.N.97,I.N.30)

Spec: (As directed by Engineer in charge)


31 Providing and fixing Modular false ceiling of 600 x 600 mm centre to
centre and 13 mm thick square mineral fiber board to be fixed on
frame work of alluminium sections for suspended false ceiling
consisting of alluminium T 2"x1 1/2" (50 mm x 40 mm) weighing
0.39 kg/m at 60 cms centre centre and fixed with 1/2" x 1/2" (15 x 15
mm) flanges weighing 0.19 kg/m suspended on 6 mm dia mild steel
rod weighing 0.22 kg/m fixed on wall and beams including rounding
of the edges with alluinium T of 2" x 1 1/2" (50 mm x 40 mm)
weighing 0.39 kg/m etc. (all alluminium sections shall be anodized)
including all labour, material, lifts etc.complete.(PWDSR.2013/14,
P.N.97,I.N.31)

Spec: (As directed by Engineer in charge)


PAGE NO : 97
32 Providing and fixing 2.5 to 3.00 mm thick Acrylic decorative sheet
roofing including galvanized iron J or L hook bolts, galvanised iron
and bituminous washers, galvanized iron cramp bolts, nuts and
scaffolding complete.(PWDSR.2013/14, P.N.98,I.N.32)
Spec: (As directed by Engineer in charge)
33 Providing and fixing 15mm thick eco-friendly densified edged
calcium silicate false ceiling tiles (like Aerolite) of approved texture
spintone/cosmos/Hexa or equivalent of size 595 mm x 595 mm in true
horizontal level, suspended on inter locking metal grid of hot dipped
galvanised steel sections (galvanizing @ 120 grams per square metre.
including both side) consisting of main "T" runner suitably spaced at
joints to get requried length and of size 24X38 mm made from 0.33
mm thick (minimum) sheet, spaced 1200mm centre to centre, and
cross "T" of size 24x28 mm made for 0.33 mm thick (minimum) sheet
to be inter locked at middle of the 1200x600 mm panel to from grid of
size 600x600mm, resting on periphery walls / partitions on a perimeter
wall angle precoated steel of size (24X24X300mm) made of 0.40 mm
thick (minimum) sheet with the help of rawl plugs at 450 mm and
laying 15 mm thick densified edges calcium slicate ceiling tiles of
approved texture (Spintone/cosmos/hexa) in the grid, including, light
fittings, fixture, smoke detectors etc., wherever requried. Main "T"
runners to be suspended from ceiling with using G.I. slotted cleats of
size 25X35X1.6mm fixed to ceiling using with 12.5 mm dia and 50
mm long dash fasteners, 4 mm G.I. adjustable rods with galvanized
steel level clips of size 85X30X0.8mm, spaced at 1200 mm centre to
centre along main "T" bottom exposed with 24mm of all T-sections
shall be pre-painted with polyester baked paint, for all heights, as per
specifications, drawings etc. complete. (currently this item should
used only for VIP cabins).(PWDSR.2013/14, P.N.98,I.N.33)

Spec: (As directed by Engineer in charge)


Note : Only calcium silicate false ceiling area will be measured from
wall to wall. No deduction shall be made for exposed frames / opening
(cut outs) having area less than 0.30 sqm. The calcium silicate ceiling
tile shall have NRC value of 0.50 (Minimum), light reflection> 85%
non-combustible as per B.S.476 part IV, 100% humidity resistance and
also having thermal conductivity <0.043 w/m 0 KC.
(PWDSR.2013/14, P.N.98,I.N.33)

Uses : Hospitals, office and commerical Buildings, Auditorium and


Cinema Hall, Educational Institutions, R&D Centers, Studios,
Libraries.
PAGE NO : 98
34 Providing and fixing false ceiling with eco-friendly light weight
calcium silicate tiles of Spintone surface textured "Aerolite" make or
equivalent of size 595 x 595 mm having 15 mm thick densified micro
look edge and 100 % humidity resistance, incombustible as per BS
476 part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50
placed in true horizontal level suspended grid of size 600x600 mm
made from hot dipped GI steel sections on sillhouette profile, rotary
stitched double webbed white with 6mm reveal profile (white/black) ,
where in main "T" runner of size 42 mm x 14 mm and between main
tee at 600 mm centre to centre and secondary cross "T" of size 33x14
mm x 0.40 thick of length 600 mm long spaced itner locked at middle
of the first cross "T" in each pannel to form grids of 1200mm x
600mm and resting on periphery wall profile wall section 19mm (7+7)
x 19mm x 0.40 thickness and laying false ceiling for services like
diffusers grills including cutting, making opening for light fitting,
fixtures, smoke detectors etc. whatever requried, main tee runner to be
suspended form ceiling using G.I. soffit cleats of size 25x35x1.6 mm
of requried length fixed to the ceiling with 6mm dia. and 50mm long
dash fastener, 4mm, dia. G.I. adjustable rods with powder coated /
good quality G.I. level adjustment clips of 35x30x08 mm spaced at
1200, center to center along main tee all complete at all complete at all
heights as per specifications, drawings and as per direction of
Engineer in charge.(PWDSR.2013/14, P.N.99,I.N.34)

Spec: (As directed by Engineer in charge)


PAGE NO : 99
BD-T : DOORS, WINDOWS, VENTILATORS AND PARTITI
1 Providing and fixing ….. as per drawing for second class doors
without ventilators, windows, fanlights, etc. including all mouldings,
rebating, holdfasts and finishing with one coat of primer complete.
(PWDSR.2013/14, P.N.101,I.N.1)
Bd/T-2 P-478 a) Country teak wood frame
Bd/T-2 P-478 b) Non teak wood frame
Bd/T-2 P-478 c) Burma Teak wood frame
VENTILATORS
2 Bd/T-4 P-479 Providing and fixing C.C.T.W. second class fully glazed 40mm thick
ventilator rectangular in shape adopting sections and sizes as given in
standard specificationsVolume-II (1981) or as per drawings including
chromium plated fixtures and fastenings and finishing the wood work
with one coat of primer complete. (Without frame and mild steel bar).
(PWDSR.2013/14, P.N.101,I.N.2)

3 Bd/T-4 P-479 Providing and fixing C.C.T.W. second class fully glazed 40mm thick
fixed fanlight rectangular in shape adopting sections and sizes as given
in standard specificationsVolume-II (1981) or as per drawings
including finishing with one coat of primer complete. (Without frame
and mild steel bar).(PWDSR.2013/14, P.N.101,I.N.3)
PANELLED DOORS
4 Bd/T-7 P-481 Providing and fixing C.C.T.W. double leaf 40mm thick second class
fully panelled door without fanlights adopting sections and sizes as
given in the standard specifications Volume-II (1981) or as per
detailed drawings including chromium plated fixtures and fasterings
and finishing the wood work with one coat of primer complete.
(Without frame).(PWDSR.2013/14, P.N.101,I.N.4)

5 Bd/T-7 P-481 Providing and fixing C.C.T.W. double leaf 40mm thick second class
fully panelled door without fanlights adopting sections and sizes as
given in the standard specifications Volume-II (1981) or as per
detailed drawings including brass fixtures and fastenings and finishing
the wood work with one coat of primer complete. (Without frame).
(PWDSR.2013/14, P.N.101,I.N.5)

PAGE NO : 101
6 Bd/T-8 P-482 Providing and fixing C.C.T.W. single leaf 40mm thick second class
fully panelled door without ventilator adopting sections and sizes as
given in the standard specifications Volume-II (1981) or as per
detailed drawings including chromium plated fixtures and fastenings
and finishing the wood work with one coat of primer complete.
(Without frame).(PWDSR.2013/14, P.N.102,I.N.6)

7 Bd/T-8 P-482 Providing and fixing C.C.T.W. single leaf 40mm thick second class
fully panelled door without ventilator adopting sections and sizes as
given in the standard specifications Volume-II (1981) or as per
detailed drawings including brass fixtures and fasterings and finishing
the wood work with one coat of primer complete. (With-out frame).
(PWDSR.2013/14, P.N.102,I.N.7)

8 Bd/T-11 P-482 Providing and fixing C.C.T.W. double leaf 40mm thick second class
partly panclled partly glazed door without ventilator adopting sections
and sizes as given in standard specifications Volume-II (1981) or as
per detailed drawings including chromium plated fixtures and
fastenings and finishings the wood work with one coat of primer
complete. (Without frame). (PWDSR.201./14, P.N.102,I.N.8)

9 Bd/T-12 P-483 Providing and fixing C.C.T.W. double leaf 40mm thick second class
partly panelled partly glazed door without ventilator adopting sections
and sizes as given in standard specifications Volume-II (1981) or as
per detailed drawings including brass fixtures and fastenings and
finishing the wood work with one coat of primer complete.
(PWDSR.2013/14, P.N.102,I.N.9)

10 Bd/T-12 P-483 Providing and fixing C.C.T.W. single leaf 40mm thick second class
partly panelled partly glazed door without ventilator adopting sections
and sizes as given in standard specifications Volume-II (1981) or as
per detailed drawings including chromium plated fixtures and
fastenings and finishing the wood work with one coat of primer
complete. (Without frame). (PWDSR.2013/14, P.N.102,I.N.10)
11 Bd/T-12 P-483 Providing and fixing C.C.T.W. single leaf 40mm thick second class
partly panelled partly glazed door without ventilator adopting sections
and sizes as given in standard specifications Volume-II (1981) or as
per detailed drawings including brass fixtures and fastenings and
finishing the wood work with one coat of primer complete. (Without
frame).(PWDSR.2013/14, P.N.102,I.N.11)

PAGE NO : 102
12 Bd/T-21 P-493 Providing and fixing C.C.T.W. double leaf 22mm thick second class
plain planked door without ventilator adopting sections and sizes as
given in standard specifications Volume-II (1981) or as per detailed
drawings including chromium plated fixtures and fastenings and
finishing the wood work with one coat of primer complete. (Without
frame).(PWDSR.2013/14, P.N.103,I.N.12)

13 Bd/T-22 P-494 Providing and fixing C.C.T.W. single leaf second class 22 mm thick
plain planked door without ventilator adoptings sections and sizes as
given in standard specifications Volume-II (1981) or as per detailed
drawings including chromium plated fixtures and fastenings and
finishing the wood work with one coat of primer complete. (Without
frame).(PWDSR.2013/14, P.N.103,I.N.13)

14 Bd/T-23 P-494 Providing and fixing country teak wood double leaf second class 22
mm thick false panelled door without fanlight, fixing 10 mm thick
scantling to give apperance of panels as per detailed drawings
including chromium plated fixtures and fastenings and finishing the
wood work with one coat of primer complete. (Without frame).
(PWDSR.2013/14, P.N.103,I.N.14)

15 Bd/T-23 P-494 Providing and fixing country teak wood double leaf second class 28
mm thick false penelles door without fanlight, fixing 10 mm thick
scantiling to give appearance of panels as per detailed drawing
including chromium plated fixtures and fastenings and finishing the
wood work with one coat of primer complete. (Without frame).
(PWDSR.2013/14, P.N.103,I.N.15)

16 Bd/T-24 P-494 Providing and fixing country teak wood single leaf second class 22
mm thick false panelled door without ventilator, fixing 10 mm thick
scantling to give appearance of panels as per detailed drawings
including chromium plated fixtures and fastenings and finishing the
wood work with one coat of primer complete. (without frame).
(PWDSR.2013/14, P.N.103,I.N.16)

17 Bd/T-24 P-494 Providing and fixing country teak wood single leaf second class 28
mm thick false panelled door without ventilator, fixing 10 mm thick
scantling to give appearance of panels as per detailed drawing
including chromium plated fixtures and fastenings and finishing the
wood work with one coat of primer complete. (Without frame).
(PWDSR.2013/14, P.N.103,I.N.17)

PAGE NO : 103
18 Bd/T-27 P-495 Providing and fixing 25 mm thick country teak wood single swing
shutter part size panelled as per detailed drawing including double
acting brass spring hinges and finishing with french polishing
complete.(Without frame).(PWDSR.2013/14, P.N.104,I.N.18)
19 Bd/T-28 P-496 Providing and fixing 25 mm thick country teak wood single swing
shutter part size panelled with obscured glass as per detailed drawing
or as approved including double acting brass spring hings and
finishing with french polishing complete. (Without frame).
(PWDSR.2013/14, P.N.104,I.N.19)

FLUSH DOOR SHUTTER


20 Bd/T-34 P-499 Providing and fixing solid core flush door in single leaf 35 mm thick
decorative type of exterior grade as per detailed drawings, approved
face veneer on both faces without glazing and venetians, all necessary
beads, moulding and lipping, brass oxidised fixtures and fastenings
with mortise lock, chromium plated handles on both sides amd
finishing with french polishing etc. complete. (Without frame).
(PWDSR.2013/14, P.N.104,I.N.20)

21 Bd/T-34 P-499 Providing and fixing solid core flush door in single leaf 35 mm thick
commercial type of exterior grade as per detailed drawings, approved
commercial plywood facing on both sides without glazing and
venetians, all necessary beads, mouldings and lipping, chromium
plated handles on both sides and finishing with french polishing erc.
complete. (Wiyhout frame).(PWDSR.2013/14, P.N.104,I.N.21)

PANELLED DOORS SHUTTERS WITH TEAK WOOD PARTICLE


BOARD
22 Providing and fixing single leaf panelled door shutters 35 mm thick as
per detailed drawings consisting of country cut teak wood styles, top
rail, frieze rail of 100 mm x 35 mm, lock rail of 160 mm x 35 mm and
bottom rail of 250 mm x 35 mm and insert panels of 12 mm thick,
both sides decorative teak faced veneer teak wood particle board
bonded with phenol formaldehyde synthetic resin, B.W.P. exterior
grade generally conforming to IS: 3090-1980 including chromium
plated fixtures and fastenings with one coat of wood primer etc.
complete. (Excluding door frame).(PWDSR.2013/14, P.N.104,I.N.22)

Spec: (As directed by Engineer in charge)


PAGE NO : 104
23 Providing and fixing single leaf panelled door shutters 35 mm thick as
per detailed drawings consisting of country cut teak wood styles, top
rail, frieze rail of 100 mm x 35 mm, lock rail of 160 mm x 35 mm and
bottom rail of 250 mm x 35 mm and insert panels of 12 mm thick, one
side decorative teak faced veneer and other side commerical ply face
teak wood particle board bonded with phenol formaldehyde synthetic
resign, B.W.P. exterior grade generally conforming to IS: 3090-1980
including chromium plated fixtures and fastenings with one coat of
wood primer etc. complete. (Excluding door frame).
(PWDSR.2013/14, P.N.105,I.N.23)

Spec: (As directed by Engineer in charge)


24 Providing and fixing single leaf panelled door shutters 35 mm thick as
per detailed drawings consisting of country cut teak wood styles, top
rail, frieze rail of 100 mm x 35 mm, lock rail of 160 mm x 35 mm and
bottom rail of 250 mm x 35 mm and insert panels of 12 mm thick,
both sides commercial ply faced teak wood particle board bonded with
phenol formaldehyde synthetic resign, B.W.P. exteior grade generally
conforming to IS: 3090-1980 including chromium plated fixtures and
fastenings with one coat of wood primer etc. complete. (Excluding
door frame).(PWDSR.2013/14, P.N.105,I.N.24)

Spec: (As directed by Engineer in charge)


25 Providing and fixing single leaf panelled door shutters 35 mm thick as
per detailed drawings consisting of country cut teak wood styles, top
rail, frieze rail of 100 mm x 35 mm, lock rail of 160 mm x 35 mm and
bottom rail of 250 mm x 35 mm and insert panels of 12 mm thick, teak
wood particle board bonded with phenol formaldehye synthetic resign,
B.W.P. exterior grade generally conforming to IS: 3090-1980
including chromium plated oxidised fixtures and fastenings with one
coat of wood primer etc. complete. (Excluding door frame).
(PWDSR.2013/14, P.N.105,I.N.25)

Spec: (As directed by Engineer in charge)


26 Providing and fixing fibre glass reinforced polyester door shutter 30
mm thick as per IS: 14856 (2000) (Reaffirmed 2006) without
ventilator including chromium plated fixtures and fastening with
chromium plated handles on both sides etc. complete.
(PWDSR.2013/14, P.N.105,I.N.26)

Spec: (As directed by Engineer in charge)


PAGE NO : 105
27 Providing and fixing fibre glass reinforced polyester door shutter 35
mm thick as per IS : 14856 (2000) (Reaffirmed 2006) without
ventilator including chromium plated fixtures and fastening with
chromium plated handles on both sides etc. complete.
(PWDSR.2013/14, P.N.106,I.N.27)

Spec: (As directed by Engineer in charge)


28 Providing and fixing brass peep window of approved quality, type,
make, size and shape etc. to door shutter complete. (PWDSR.2013/14,
P.N.106,I.N.28)
Spec: (As directed by Engineer in charge)
29 Providing and fixing C.C.T.W. beading/lipping for flush door shutter
including finishing complete.(PWDSR.2013/14, P.N.106,I.N.29)
Spec: (As directed by Engineer in charge)
30 Providing and fixing vision panel in flush type door shutters with plain
glass etc. complete.(PWDSR.2013/14, P.N.106,I.N.30)
Spec: (As directed by Engineer in charge)
31 Providing and fixing wooden venetians in flush type door shutter as
per approved type etc. complete.(PWDSR.2013/14, P.N.106,I.N.31)

Spec: (As directed by Engineer in charge)


32 Providing and fixing hydraulic door closer of approved quality and
make to door shutter including making proper adjustment for smooth
operation etc. complete.(PWDSR.2013/14, P.N.106,I.N.32)
Spec: (As directed by Engineer in charge)
33 Provding and fixing in postion night latch of approved make, quality
Spec: (As directed by Engineer in charge)
WINDOWS
34 Bd/T-41 P-502 Providing and fixing country teak wood 25 mm thick double leaves
first class windows adopting sections and sizes as given in Standard
Specifications Volume-II (1981) with plain glass shutters without
ventilators/ fanlights as per detailed drawings including brass oxidised
fixtures and fastenings and finishing the wood work with one coat of
primer complete. (Without frame and mild steel bars).
(PWDSR.2013/14, P.N.106,I.N.34)

PAGE NO : 106
35 Bd/T-42 P-503 Providing and fixing country teak wood 25 mm thick double leaves
second class windows adopting sections and sizes as given in Standard
Specifications Volume-II (1981) with plain glass shutters without
ventilators/ fanlights as per detailed drawings including chromium
plated fixtures and fastenings and finishing the wood work with one
coat of primer complete. (Without frame and mild steel bars).
(PWDSR.2013/14, P.N.107,I.N.35)

36 Bd/T-41 P-502 Providing and fixing country teak wood 30 mm thick double leaves
first class windows adopting sections and sizes as given in Standard
Speccifications Volume-II (1981) with plain glass shutters without
ventilators/ fanlights as per detailed drawings including brass oxidised
fixtures abd fastenings and finishing the wood work with one coat of
primer complete. (Without frame and mild steel bars).
(PWDSR.2013/14, P.N.107,I.N.36)
37 Bd/T-42 P-503 Providing and fixing country teak wood 30 mm thick double leaves
second class windows adopting sections and sizes as given in Standard
Specifications Volume-II (1981) with plain glass shutters without
ventilators/ fanlights as per detailed drawings including chromium
plated fixtures and fastenings and finishing the wood work with one
coat of primer complete. (Without frame and mild steel bars).
(PWDSR.2013/14, P.N.107,I.N.37)

38 Bd/T-43 P-503 Providing and fixing country teak wood 22 mm thick window
adopting sections and sizes as given in Standard Specifications
Volume-II (1981) with double leaf planked shutters as per detailed
drawings including chromium plated fixtures and fastenings and
finishings the wood work with one coat of primer complete. (Without
frame and mild steel bars). (PWDSR.2013/14, P.N.107,I.N.38)

39 Bd/T-43 P-503 Providing and fixing double leaves second class windows with
panelled shutters 35 mm thick with panels 25 mm thick without
ventilators/ fanlights as per detailed drawings with chromium plated
fixtutes and fastenings and finishing the wood work woth one coat of
primer complete. (Without frame). (PWDSR.2013/14, P.N.107,I.N.39)

PAGE NO : 107
40 Providing and fixing single leaf second class windows with oanelled
shutters 35 mm thick with panels 25 mm thick without ventilators/
fanlights as per detailed drawings with chromium plated fixtures and
fastenings and finishing the wood work with one coat of primer
complete. (Without frame).(PWDSR.2013/14, P.N.108,I.N.40)

Spec: (As directed by Engineer in charge)


41 Providing and fixing double leaves second class windows with false
panelled shutters 22 mm thick and covering planks 10 mm thick
without ventilators/ fanlights as per detailed drawings including
chromium plated fixtures and fastenings and finishing the wood work
with one coat of primer etc. complete. (Without frame and mild steel
bars).(PWDSR.2013/14, P.N.108,I.N.41)

Spec: (As directed by Engineer in charge)


42 Providing and fixing single leaf second class windows with false
panelled shutters 22 mm thick and covering planks 10 mm thick
without ventilators/ fanlights as per detailed drawings including
chrpmium plated fixtures and fastenings and finishing the wood work
with one coat of primer etc. complete. (Without frame and mild steel
bars).(PWDSR.2013/14, P.N.108,I.N.42)

Spec: (As directed by Engineer in charge)


43 Bd/T-52 P-509 Providing and fixing country cut teak wood louvered windows with
teak wood frame 60 x 100 mm and glass louvers of approved quality
with 16 mm dia. mild steel bars placing of M.S. bar between louvers
including finishing wood work and iron work with one coat of primer
complete. MILD STEEL BARS FOR
WINDOWS/ VENTILATORS/ FANLIGHTS. (PWDSR.2013/14,
P.N.108,I.N.43)

44 Providing and fixing 16 mm dia. mild steel round bars at 100 mm


centre to centre to windows/ ventilators/ fanlights, fixing mild steel
flats 40 x 6 mm in frame, cutting a recess to fit the flat exactly
including drilling the holes to flats to pass the bars through it 25 mm
inside in wooden frame including providing ...... of 40 x 6 mm by
drilling holes (when bar length exceeds 75 cm including one coat of
primer etc. complete.(PWDSR.2013/14, P.N.108,I.N.44)

Spec: (As directed by Engineer in charge)


a) two central flats
b) one central mild steel flat
c) without central mild steel flats
PAGE NO : 108
45 Providing and fixing 16 mm dia steel bars to windows at 100 mm
centre to centre including one coat of primer etc. complete. (Without
M.S. flats).(PWDSR.2013/14, P.N.109,I.N.45)
Spec: (As directed by Engineer in charge)
STEEL WINDOWS
46 Providing and fixing steel windows of various sizes as per detailed
drawings with hot dip zine coating ….. Conforming to IS : 1038-1975
and sections confiming to IS : 7452-1982 including fabricating,
glazing with 3 mm thick obscured glass panes of approved quality and
all fixtures and fastenings including alluminium beading 12 mm x 12
mm weighing @ 0.148 kg per metre, scaffolding, painting etc.
complete.(PWDSR.2013/14, P.N.109,I.N.46)

Spec: (As directed by Engineer in charge)


a) without ventilator with side hung shutters
b) without ventilator with centre hung shutters
47 Providing and fixing steel ventilators of various sizes as per detailed
drawings with hot dip zinc coating …… conforming to IS: 1038-1975
and sections conforming to IS: 7452-1982 including fabricating,
glazing with 3 mm thick obscured glass panes of approved quality and
all fixtures and fastenings including alluminium beading 12 mm x 12
mm weighing @ 0.148 kg per metre, scaffolding, painting etc.
complete.(PWDSR.2013/14, P.N.109,I.N.47)

Spec: (As directed by Engineer in charge)


a) with top hung shutters
b) with side hung shutters
ALLUMINIUM WINDOWS
48 Providing and fixing in position anodised extruded alluminium
openable windows having frame made out of alluminium section of
outer frame size 53 mm x 57 mm (or of requried size with
proporationate change in weight) of average weight @ 1.118 kg/Rmt
and shutter of 53 mm x 57 mm (or as requried size) of average weight
of 0.30 kg/Rmt (or as requried ) with plain sheet glass 5.5 mm thick
with neroprene gasket with hings, locking arrangement and wooden
encasement wherever necessary etc. complete.(PWDSR.2013/14,
P.N.109,I.N.48)

Spec: (As directed by Engineer in charge)


PAGE NO : 109
49 Providing and fixing in position extruded modular alluminium fixed
glass panel windows having frame made out of extruded tubular
section of size 63 mm x 38 mm x 2.00 mm thickness (wt. 1.054
kg/Rmt) mechanically assembled at corners with glazing, beadings of
angle 25 mm x 25 mm x 1.60 mm thick (Wt. 0.21kg /Rmt) including
plain sheet glass 5.5 mm thick with rubber gasket and wooden
encasement wherever necessary etc. as per approved drawings and
specifications etc. complete. (PWDSR.2013/14, P.N.110,I.N.49)

Spec: (As directed by Engineer in charge)


50 Providing and fixing in position extruded modular alluminium section
two track sliding window mounted on rectangular frame of size 63
mm x 38 mm x 2.00 mm thick (1.054 kg/Rmt) made up of two track
drain bottom section of size 61 mm x 45 mm x 1.3 mm thick (1.055
kg/Rmt) and top and sides sections of size 61 mm x 45 mm x 1.3 mm
thick (1.055 kg/Rmt) and top and sides sections of size 61 mm x 31
mm x 1.3 mm thick (0.659 kg/Rmt). The shutter should be of bearing
bottom of size 40 mm x 18 mm x 1.25 mm thick (0.417 kg/Rmt) top
member of size 40 mm x 18 mm x 1.20 mm thick (0.475 kg/Rmt)
Interlocking section size of 43 mm x 27 mm x 1.30 mm thick (0.558
kg/Rmt) and handle section of size 43 mm x 18 mm x 1.30 mm thick
(0.424 kg/Rmt), selected quality 5.5 mm thick clear glass to be fixed
in shutter with neoprene gasket with approved quality PVC rollers,
necessary locks, handles, pVC lining and wooden encasement
wherever necessary etc. complete. (PWDSR.2013/14, P.N.110,I.N.50)

Spec: (As directed by Engineer in charge)


a) Without Powder Coating
b) With Powder Coating
PAGE NO : 90
51 Providing and fixing in position extruded modular alluminium section
three track sliding (upto 1.20 mtr. height) window mounted on
rectangular frame of size 100 mm x 40 mm x 1.30 mm thick (wt
0.976 kg/Rmt) made up of three track drain bottom section of size 92
mm x 45 mm x 105 mm thick (1.659 kg/Rmt) Three track top and
sides of size 92 mm x 31 mm x 1.3 mm thick (0.933 kg/Rmt) The
shutter comprising of bottom and top member of size 40 mm x 18 mm
x 1.25 mm thick (0.417 kg/Rmt) Interlocking section of size 40 mm x
18 mm x 1.10 mm thick (0.469 kg/Rmt) handle sides of 40 mm x 18
mm x 1.25 mm thick (0.417 kg/Rmt) with 5.5 mm thick selected
quality clear glass fixed in shutter with approved quality neoprene
gasket, PVC rollers, locks, handles, PVC lining and wooden
encasement wherever necessary etc. complete. (PWDSR.2013/14,
P.N.111,I.N.51)

Spec: (As directed by Engineer in charge)


a) Without Powder Coating
b) With Powder Coating
52 Providing and fixing in position extruded modular alluminium section
Two Track Sliding Window (Excluding frame) made up of two drack
drain bottom section of size 61 mm x 45 mm. x 1.3 mm thick (1.055
kg/Rmt) and top and side sections of size 61 mm x 31 mm. x 1.3 mm
thick (0.659 kg/Rmt). The shutter should be bearing bottom of size
40mm.x 18mm.x 1.2 mm thick (0.417 kg/Rmt) top number of size
40mm. x 18mm. x 1.20mm Thick (0.475 kg/Rmt) Interlocking section
size of 43mm x 27mm.x1.30mm thick (0.558 kg/Rmt) and handle
section of size 43mm x 18mm x 1.30mm thick (0.424 kg/Rmt)
selected quality 5.5.mm. thick tinted glass to be fixed in shutter with
neoprene, gasket with approved quality P.V.C. rollers, necessary locks
handles, P.V.C. lining etc. complete. (Excluding frame).
(PWDSR.2013/14, P.N.111,I.N.52)

Spec: (As directed by Engineer in charge)


a) Without Powder Coating
b) With Powder Coating
PAGE NO : 111
53 Providing and fixing in position extruded modular alluminium section
three track sliding window made up to three track drain bottom section
of size 92mm. x 45 mm. x 1.05 mm. thick (1.659 kg/Rmt) three track
top and sides section of size 92mm. x 31 mm. x 1.30mm. thick (0.933
kg/Rmt) The shutter comprising of bottom and top member of size
40mm.x18mm.x1.25mm thick (0.417 kg/Rmt) Interlocking section of
size 40mm.x18mm.x1.10mm. thick (0.469 kg/Rmt) handles
section of size 40mm x 18mm x 1.25mm thick (0.417 kg/Rmt) with
5.5 mm. thick selected quality tinted glass fixed in shutter with
approved quality neoprene, gasket, P.V.C. lining etc. complete.
(Excluding frame).(PWDSR.2013/14, P.N.112,I.N.53)
Spec: (As directed by Engineer in charge)
a) Without Powder Coating
b) With Powder Coating
54 Providing and fixing aluminum louvered windows consisting of
vertical arm (40x12mm) with holders, lever and locking arrangement
weighing at 0.91 kg/Rmt. with 3mm thick sheet glass louvers
including fillig the gaps in joints of cladding and external/internal
adjointing portion with plaster silicon jelly with gun etc. complete.
(PWDSR.2013/14, P.N.112,I.N.54)

Spec: (As directed by Engineer in charge)


55 Replacing by providing and fixing 3 mm thick plain sheet glass of
doors and windows etc. including putty complete. (PWDSR.2013/14,
P.N.112,I.N.55)
Spec: (As directed by Engineer in charge)
56 Replacing by providing and fixing 3 mm thick rubbed glass of doors
and windows etc. including putty completed.(PWDSR.2013/14,
P.N.112,I.N.56)
Spec: (As directed by Engineer in charge)
57 Replacing by providing and fixing 3 mm thick excellent clarity plain
acrylic sheet glass of approved quality and make for doors and
windows including drilling the hole and fixing with iron screws if
necessary and filling the putty of approved quality etc. complete.
(PWDSR.2013/14, P.N.112,I.N.57)

Spec: (As directed by Engineer in charge)


PAGE NO : 112
ROLLING SHUTTERS
58 Providing and fixing rolling sheet shutter fabricated from 18/20 gauge
steel laths with side guides, bottom rail, brackets, door suspension
shaft including…… with one coat of red lead primer etc. complete.
(PWDSR.2013/14, P.N.113,I.N.58)
Bd/T-56 P-510 a) rolling springs, locking arrangement and housing box at the top
(*)
(*) (Except mechanical gear box)
Bd/T-56 P-511 b) 3 ball bearings and housing box at the top
(*)
Bd/T-56 P-511 c) housing box at the top including mechanical gear operation
arrangement
59 Bd/T-57 P-511 Providing and fixing collapsible steel gates in two leaves with channel
pickets, pivoted flat bars including top and bottom guide rollers,
stoppers, handles, all fittings and accessories, locking arrangement and
applying one coat of red lead primer complete.(PWDSR.2013/14,
P.N.113,I.N.59)

PARTITIONS
60 Providing and fixing partitions using 1.84 metre height using with
phenol formaldehyde synthetic resign including C.C.T.W. vertical 70 x
70 mm and top and bottom rail of 70 x 35 mm and covering batten of
30 x 10 mm at 1.22 meter apart on both ways or as directed including
finishing with one coat of primer complete.(PWDSR.2013/14,
P.N.113,I.N.60)

Bd/T-63 P-514 a) 12 mm thick teak wood particle board

Bd/T-63 P-514 b) 12 mm thick teak wood particle board housing one face teak veneer

Bd/T-63 P-514 c) 12 mm thick teak wood particle board with both faces teak veneer

61 Bd/T-68 P-515 Providing and fixing partitions of 3.5 mm to 4 mm thick Indian teak
veneer on both sides including C.C.T.W. frame of 70 x 35 mm at 60
cm c/c including fnishing with french polishing complete. (Without
skirting).(PWDSR.2013/14, P.N.113,I.N.61)
PAGE NO : 113
62 Providing and fixing partitions of 3.5 mm to 4 mm thick Indian teak
veneer on one side and 4 mm .................. on the other side including
C.C.T.W. frame of 70 x 35 mm at 60 cm c/c including finishing with
french polishing to veneer face and oil painting/ french polishing to
other face etc. complete. (Without skirting).(PWDSR.2013/14,
P.N.114,I.N.62)

Bd/T-68 P-515 a) Commercial Plywood

Bd/T-68 P-515 b) Marine Plywood

63 Providing and fixing country teak wood party veneered and party
glazed partition with 70 x 35 mm frame at 60 cm centre to centre and
decorative veneer of 4 mm thick including french polishing etc.
complete..(PWDSR.2013/14, P.N.114,I.N.63)
Spec: (As directed by Engineer in charge)
64 Providing and fixing strorage cabinet made of 19 mm thick
........including shelf of 400 mm to 450 mm centre to centre and
shutters both made of 19 mm thick commerical plywood, back
covered with 6 mm commerical ply wood and storage unit is finished
externally with approved quality 1 mm thick laminate including
finishing inner side and back side by two coat of french polish with
necessary fixtures and fastenings as per detailed design and drawings
etc. complete.(PWDSR.2013/14, P.N.114,I.N.64)

Spec: (As directed by Engineer in charge)


a) Commercial Plywood
b) Marine Plywood
SKIRTING / RUNNER COVER MOULDING
65 Providing and fixing teak wood runner 6" x 3" size over partition
including rounding, fixing in the masonry where necessary including 3
coats of fench polishing, necessary beading on sides etc. complete as
directed by Engineer in-Charge. .(PWDSR.2013/14, P.N.114,I.N.65)

Spec: (As directed by Engineer in charge)


66 Providing and fixing teak wood cover moulding 45 x 20 mm over
doors and windows in the requried position as per drawing including
all mouldings and finishing with french polishing etc. complete.
(PWDSR.2013/14, P.N.114,I.N.66)
Spec: (As directed by Engineer in charge)
PAGE NO : 114
67 Providing and fixing welded mesh of …… and 2.54 mm thick (12
guage) to teak wood frame work as per detailed drawings or as
directed, iron fastenings, one coat of primer, scaffolding etc. complete.
(Frame work of 70 mm x 45 mm and covering battens of 45 x 10 mm
to be paid separately).(PWDSR.2013/14, P.N.115,I.N.67)

Spec: (As directed by Engineer in charge)


a) 75 mm x 25 mm
b) 50 mm x 25 mm
c) 25 mm x 25 mm
d) 50 mm x 50 mm
68 Providing and fixing ….. XPM of 2.54 thick (12 guage) to teak wood
frame work as per detailed drawing or as directed, iron fastenings, one
coat of primer, scaffolding etc. complete. (Frame work of 70 mm x 45
mm and covering battens of 45 x 10 mm to be paid separately).
(PWDSR.2013/14, P.N.115,I.N.68)

Spec: (As directed by Engineer in charge)


a) 25 mm
b) 20 mm
WEATHER SHEDS
69 Providing and fixing …… on top of weather sheds including
scaffolding, fixing by means of nut and bolts or as directed etc.
complete. (Brackets of 70 mm x 45 mm to be paid separately).
(PWDSR.2013/14, P.N.115,I.N.69)
Spec: (As directed by Engineer in charge)
a) 22 B.W.G. plain galvanised iron sheets
b) plain asbestos cement sheet
70 Providing and fixing 24 gauge plain alluminium sheet on the face of
door shutter of W.C/ Bath including cutting to requried size and fixing
by screws including making good the damages if any to existing door
shutter and frame etc. complete.(PWDSR.2013/14, P.N.115,I.N.70)

Spec: (As directed by Engineer in charge)


PAGE NO : 115
71 Providing and fixing in position C.C.T.W. brackets for weather sheds
of section 70 x 45 mm with mortise and tenon joinery at 1.2 to 1.5
metre centre to centre or as directed and teak wood battens of requried
section including fixing three numbers of iron nut and bolts to each
bracket, necessary scaffolding and two coats of painting to wood
work etc. complete. (PWDSR.2013/14, P.N.116,I.N.71)

Spec: (As directed by Engineer in charge)


72 Removing doors and windows of any size and type….., mild steel/
wrought iron grill work and stacking the same in compound or in
P.W.D. Chowky.(PWDSR.2013/14, P.N.116,I.N.72)
Bd/W-8 P-587 a) with frame

Bd/W-8 P-587 b) without frame

73 Bd/W-8 P-587 Removing teak wood panelled/ partly glazed or veneer partitions
carefully without damaging the frame or panels and stacking the same
as and where directed.(PWDSR.2013/14, P.N.116,I.N.73)
Note : Following item No. 75 to 90 should not be executed before
prior approval of superintending Engineer
74 Providing and fixing in position precast R.C.C. (as per IS 456-2000)
M-40 grade concrete frames for doors/ windows/ louver windows of
section 125 x 50 mm with two tor steel bars of 8 mm / 10 mm for
reinforcement and concrete having diameter for compressed strength
of 400 kg/square centimetre with wood like finish having 3 numbers
of 12 guage M.S. galvanized plates of vertical members for fixing
hinges with 4 numbers of threaded holes in each plate,2 numbers of 12
mm dia. holes on horizontal top members for tower bolts, 2 numbers
of 16 mm dia. holes on vertical members for fixing Aldrop or Tadi, 3
numbers G.I Machine screws of 3/16" x 3/8", 6 numbers of M.S.
galvanized specially designed hold fast anchored with tor steel bars of
vertical members etc. complete (with all lead) excluding painting to
the frame.(PWDSR.2013/14, P.N.116,I.N.74)

Spec: (As directed by Engineer in charge)


PAGE NO : 116
75 Providing and fixing factory made precast door/windows frames of
cement concrete (as per IS-456-2000) M-30 grade of section 100 x 60
mm including reinforcement as per I.S. 6523 with polymetric blocks
having screw holding capacity of 250 kg. fixed in position of R.C.C.
frame as per requirement and as per specifications without fan light
including holdfasts, carting and erecting in position and two coats of
oil paint etc. complete. (PWDSR.2013/14, P.N.117,I.N.75)

Spec: (As directed by Engineer in charge)


76 Providing and fixing anodized alluminium fully glazed doors
including door frame with powder coating 5 mm thick sheet glass
necessary fixtures, and fastenings, neoprene type rubber plain gaskets
as per IS standard and detailed drawings etc. complete. (Sample to be
got approved from superintending Engineer before use).
(PWDSR.2013/14, P.N.117,I.N.76)

Spec: (As directed by Engineer in charge)


77 Providing and fixing sintex or equivalent door frames made out of
rigid PVC hollow, section DWUF-412 of size 38 mm x 32 mm with
steel reinforcement ST-33 of size 14 x 33 mm, machine cut and
welded and tie rod at the bottom including fixing 100 mm long
expandable screws in requried number with wooden plug expandable
screws in requried number with wooden plugs fixed in walls as
holdfasts and remaking damaged surface etc. complete. (For Toilet
Blocks).(PWDSR.2012/13, P.N.97,I.N.77)

Spec: (As directed by Engineer in charge)


78 Providing and fixing Sintex or equivalent door frames made out of
rigid PVC hollow section DWUF-405 of size 48 mm x 40 mm with
steel reinforcement ST-22 of size 22 x 18 mm, machine cut and
welded and tie rod at the bottom including fixing 100 mm long
expandable screws in requried number with wooden plugs fixed in
walls as holdfasts and remaking damaged surface etc. complete. (For
Toilet Blocks).(PWDSR.2013/14, P.N.117,I.N.78)

Spec: (As directed by Engineer in charge)


PAGE NO : 97
79 Providing and fixing Sintex or equivalent door frames made out of
rigid PVC hollow section BLR-53 of size 27 x 20 mm, machine cut
and welded and tie rod at the bottom including fixing 100 mm long
expandable screws in requried number with wooden plugs fixied in
walls as holdfasts and remaking damaged surface etc. complete. (For
Internal Rooms).(PWDSR.2013/14, P.N.118,I.N.79)

Spec: (As directed by Engineer in charge)


80 Providing and fixing of PVC make frame Choukhat having size 53 x
60 mm. The Choukhat will be attached to the wall with the help of
screws. The Choukhat will be filled with solid polymer material in all
voids necessary for fixing the screws etc. complete.(PWDSR.2013/14,
P.N.118,I.N.80)

Spec: (As directed by Engineer in charge)


81 Providing and fixing 30 mm thick single leaf door shutter of approved
quality and make of 1.5 mm thick P.V.C. shetts on both sides filled
with 'PUF' (Poly urethene foam) with three numbers of bright finished
brass butt hinges (100 x 70 x 4 mm size) with brass screws, chromium
plated fixtures and fastenings such as one number of 16 mm and 300
mm long aldrop, one number of 250 x 25 x 5mm door latch, two
numbers of 100 mm size handles etc. complete. (Excluding shutter
frame). (PWDSR.2013/14, P.N.118,I.N.81)
Spec: (As directed by Engineer in charge)
82 Providing and fixing 30 mm thick single leaf door shutter of approved
quality and make of 0.80 mm thick G.I. Sheets on both sides filled
with 'PUF' (Poly urethene foam) with three numbers of breight
finished brass butt hings (100 x 70 x 4 mm size) with brass screws,
chromium plated fixtures and fastenings such as one number of 16
mm and 300 mm long aldrop, one number of 250 x 25 x 5mm door
latch, two numbers of 100 mm size handles and finished etc. complete.
(Excluding shutter frame).(PWDSR.2013/14, P.N.118,I.N.82)

Spec: (As directed by Engineer in charge)


PAGE NO : 118
83 Providing and fixing PVC multi leaf door shutter of approved colour /
lamination made out of extruded rigid PVC hollow section PW 2459
shutter frame of size 24 x 59 mm having double wall construction as
vertical styles, top and bottom rails and middle lock rails of size 24 x
100 mm and the panel in PW 20200 multi chamber hollow plastic
section of size 20 x 200 joined each other by tongue and groove
interlocking system duly inserted in shutter frame and all shutter
frames, lock rails, styles reinforced by polymer inserted insides for
fixing of hings, aldrops, tower bolts and baby latch etc. All corners
should be machine cut joined each other by metal screw after inserting
rigid L bracket PVC reinforced of size 100 x 200 mm including
synthetic metal / alluminium with powder coating, fixtures and
fastenings remaking, damage surface etc. complete.(PWDSR.2013/14,
P.N.119,I.N.83)

Spec: (As directed by Engineer in charge)


84 Providing and fixing PVC Twin panelled single leaf door shutter of
approved colour / lamination made out of extruded rigid PVC hollow
section PW 2459 shutter frame of size 24 x 59 mm having double wall
construction as vertical styles, top and bottom rails and middle lock
rails of PW24100H of size 24 x 100mm and the panel in PW 20610
multi chamber hollow plastic section of size 20 x 610 mm duly
inserted in shutter frames, locks rails, styles reinforced by polymer
inserted inside for fixing of hinges, aldrops, tower bolts and baby latch
etc. All corners should be machine cut joined each other by metal
screw after inserting rigid L bracket PVC reinforced of size 100 x 200
mm including synthetic metal / alluminium with powder coating,
fixtures and fastenings remaking, damage surface etc. complete.
(PWDSR.2013/14,P.N.119,I.N.84)

Spec: (As directed by Engineer in charge)


PAGE NO : 119
85 Providing and fixing PVC Twin panelled single leaf door shutter of
approved colour / lamination made out of extruded rigid PVC hollow
section PW 2459 shutter frame of size 24 x 59 mm having double wall
construction as vertical styles, top and bottom rails and middle lock
rails and middle lock rails of PW24100H of size 29 x 100 mm and the
panel in PW 20610 multi chamber hollow plastic section of size 25 x
710 mm duly inserted in shutter frames, lock rails, styles reinforced by
polymer inserted inside for fixing of hinges, aldrops, tower bolts and
baby latch etc. All corners should be machine cut joined each other by
metal screw after inserting rigid L bracket PVC reinforced of size 100
x 200 mm including Synthetic metal / alluminium with powder
coating, fixtures and fastenings remaking, damage surface etc.
complete. (PWDSR.2013/14,P.N.120,I.N.85)

Spec: (As directed by Engineer in charge)


86 Providing and fixing in position anodized extruded alluminium
partitions, partly glazed and partly laminated having frame made out
of extruded tabular section of size 40 x 60 mm with 12 mm thick three
layered flat pressed teak wood particle board bonded with BWP type
exterior grade phenol formaldehyde synthetic resin conforming to I.S.
12823-1990, laminated on both sides and 5 mm thick selected quality
flat glass panels fixed with alluminium glass clips 12 x 12 mm and
rubber cushioning beading to glass partition as per approved drawings
etc. complete. (Sample to be got approved from superintending
Engineer before use).(PWDSR.2013/14,P.N.120,I.N.86)

Spec: (As directed by Engineer in charge)


87 Providing and fixing in position anodized extruded alluminium
partitions with both sides laminated panels having frame made out of
alluminium extruded tubular section of size 40 x 65 mm with 9 mm
thick three layered flat pressed teak wood particle board bonded with
BWP type exterior grade phenol formaldehyde synthetic resin
conforming to I.S. 12823-1990, laminated on both sides, fixed with
alluminium glass clips of size 12 x 12 mm as per approved drawing
etc. complete. (Sample to be got approved from Superintending
Engineer before use). (PWDSR.2013/14,P.N.120,I.N.87)

Spec: (As directed by Engineer in charge)


PAGE NO : 120
88 Providing and fixing in position anodized extruded alluminium
partition having frame made of alluminium extruded tubular section of
size 65 x 40 mm with 12 mm thick three layered flat pressed teak
wood particle board bonded with BWP type exterior grade phenol
formldehyde synthetic resin conforming to I.S. 12823-1990, laminated
on both sides, fixed with alluminium glazing clips of size 12 x 12 mm
(conical) as per drawing etc. complete. (Sample to be got approved
from Superintending Engineer before use).
(PWDSR.2013/14,P.N.121,I.N.88)
Spec: (As directed by Engineer in charge)
89 Providing and fixing alluminium grill/jali of heavy type …… opening
and 10 mm thick ……. of approved quality and design to windows
and ventilators including providing alluminium "F" Patti weighing
0.22 kg./Rmt.etc.complete as per approved drawing or as directed by
Engineer in charge. (PWDSR.2013/14,P.N.121,I.N.89)

Spec: (As directed by Engineer in charge)


a) 50 x 60 mm …… weighing 3.10 kg / smt.
b) 65 x 75 mm …… weighing 2.60 kg./smt.
c) 100 x 110 mm …… weighing 2.10 kg./smt.
Note : The above item may be used on experimental basis.
90 Supplying and fixing special type of insulated Cold Storage Door of
size as per detailed drawing and design or as directed with 100 mm
thick heavy duty insulation in two layer of 50 mm each of expanded
polyethylene and 500 micron alluminium foil vapor barrier with solid
frame superior Indian Teak Wood of 200 mm with necessary bedding
oxidised hings 6mm thick revolving on pin locking, sheet cladding
with necessary rubber gasket etc. complete.
(PWDSR.2013/14,P.N.121,I.N.90)

Note : This item included only for Special Project Circle, Mumbai.
This item should not be use by any other Circle or Division.
Spec: (As directed by Engineer in charge)
PAGE NO : 121
91 Providing and fixing Fiber Reinforced Plastic moulded weather shed
of approved colour for chajjas with FRP thickness of 2.5 to 3.00 mm
with adequate reinforcement at corners and edges, using pigments,
including FRP covered metal of wooden ribs for flat surface, fixing in
position to window frame with 10 mm dia. fasteners at not more than
2 feets centre to centre etc. complete.
(PWDSR.2013/14,P.N.122,I.N.91)

Spec: (As directed by Engineer in charge)


92 Providing and fixing Fiber Reinforced Plastic moulded weather shed
of approved colour for chajjas with FRP thickness of 2.5 to 3.00 mm
with adequate reinforcement at corners and edges, using weather able
and UV stabilised resins and pigments, including FRP covered metal
in wall by making groove and fixing in proper position with water
sealant with necessary fasteners at not than 2 feet centre to centre etc.
complete. (PWDSR.2013/14,P.N.122,I.N.92)

Spec: (As directed by Engineer in charge)


93 Providing and fixing factory made Solid PVC (polyvinyl chloride)
Door Frame in ……… manufactured by M/S Rajshri of the size 50 x
47mm with a wall thickness of 5mm, made out of extruded 5mm PVC
sheet, miter cut at two corners and joined with 2nos. of 150mmlong
brackets of 15mmx15mm M.S. square tube. The two vertical door
profiles are to be reinforced with 19mmx19mm M.S. Square tube of
19 guage, EPDM rubber gasket weather seal to be provided through
out the frame. The door frame shall be fixed to wall using65/100mm
long M.S. Screws through the frame by using PVC fasteners. A
minimum of 4nos. of screws to be provided for each vertical member
and minimum 2nos. for horizontal member etc. complete as per
manufacturers specification etc. complete.
(PWDSR.2013/14,P.N.122,I.N.93)

Spec: (As directed by Engineer in charge)


a) Plain Colour
b) Prelaminated Colour
PAGE NO : 122
94 Providing and fixing 30mm thick "RAJSHRI" BRAND FACTORY
MADE SOLID PANEL PVC DOOR SHUTTER consisting of frame
made out of M.S. tubes of 19 guage thickness and size of 19mm x
19mm for stiles and 15mm x 15mm for top and bottom rails. M.S.
frame shall have a coat of steel primers of approved make and
manufacture. M.S. frame shall be covered with 5mm thick heat
moulded "Rajshri" PVC 'C' channel of size 30 x 50mm forming stiles,
and 5mm thick, 75mm wide PVC sheets for top rail, lock rail and
bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide
cross PVC sheet as gap insert for top rail and bottom rail. Paneling of
5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to
the stiles and rails with 30mm wide x 5mm thick PVC sheet beading
on either side, and joined together with solvent cement adhesive etc.
An additional 5mm thick PVC strip of 20mm width is to be stuck on
the interior side of the 'C' Channel using PVC solvent cement adhesive
etc. complete.(PWDSR.2013/14,P.N.123,I.N.94)

Spec: (As directed by Engineer in charge)


a) Plain Colour
b) Prelaminated Colour
95 Providing and fixing 35mm thick "Rajshri" brand factory made
Moulded PVC door shutter consisting of solid core single leaf Flush
Door of 30mm thickness, lipped with 15mm (5mm x 3) thick x 30mm
width on one stiles and top rails and 10mm (5mm x 2) thick x 30mm
width on the other stiles and bottom rails, The inner panel laminated
with 2mm thick termite proof, water proof and fire resistant moilded
PVC sheet with 2,4,6 raised panel design in different Prelam colours
on one side after routing the Moulded design on flush door and 2mm
plain and / or prelam PVC sheet on other side using rubber adhesive
on flush door and solvent cement adhesive on the PVC lipping etc.
complete as per direction of Engineer-in-charge, manufacturer's
specification and drawings.(PWDSR.2013/14,P.N.123,I.N.95)

Spec: (As directed by Engineer in charge)


PAGE NO : 123
96 Providing and fixing 20 mm marine ply on exsting frame work by remov
Spec: (As directed by Engineer in charge)
97 Providing and fixing 19 mm marine ply on existing frame work by remo
Spec: (As directed by Engineer in charge)
98 Providing and fixing on site full height door shutter at require locati
Spec: (As directed by Engineer in charge)
99 Providing and fixing 4 mm thick commercial plywood with jungle wood fr
Spec: (As directed by Engineer in charge)
100 Providing and fixing shutter to wall cupboard made from 12mm thick Mar
Spec: (As directed by Engineer in charge)
101 Providing and fixing Burma Teak Wood planking 25 mm thick for roof/cei
Spec: (As directed by Engineer in charge)
102 Providing and fixing ewll seasoned Burma Teak Wood full length new memb
Spec: (As directed by Engineer in charge)
103 Fixing only Burma teak wood common rafters, purlins and purlin cleats hi
Spec: (As directed by Engineer in charge)
New Items
Note: The following all new items may be used on experimental basis for one year only.
104 Providing Sandwich panel (Pre Fab building material) by ISOBUILD PANEL
(As directed by Engineer in charge)
105 Providing and fixing Door of Sandwich panel 40mm thick of standard si
Spec: (As directed by Engineer in charge)
PAGE NO :- 126
106 Providing and fixing UPVC Door of size 1.98mX0.91m and colour along w
Spec: (As directed by Engineer in charge)
107 Providing and fixing prefabricated UPVC Door frame for door size 1.9
Spec: (As directed by Engineer in charge)
108 Providing and fixing UPVC openable window with UPVC frame made up o
Spec: (As directed by Engineer in charge)
PAGE NO :- 127
BD-U : IRON WORK
1 Bd/U-1 P-537 Providing and fixing mild steel grill work for window, ventilator
weighing 15 kg per Sqm. as per drawing including necessary welding
and painting with one coat of anticorrosive paint etc. complete.
(PWDSR.2013/14,P.N.129,I.N.1)
2 Bd/U-1 P-537 Add for extra weight or deduct for less weight for fabricating such as
cutting, shaping, riveting etc. mild steel for grill works including
welding.(PWDSR.2013/14,P.N.129,I.N.2)
3 Bd/U-2 P-537 Providing and fixing mild steel grill railing 15 kg per Sqm. with
country cut teak wood hand rail of size 75 x 60 mm and still of 75 x
25 mm for staircase including fabricating, fixtures, crecting, painting
grill work with one coat of anticorrosive paint and polishing the still,
hand rail with french polishing complete.
(PWDSR.2012/13,P.N.129,I.N.3)

4 Bd/U-2 P-537 Providing and fixing mild steel grill varandah railing 15 kg per Sqm.
With country cut teak wood hand rail of size 75 x 60 mm and still of
75 x 25 mm for verandah railing of full height including fabricating,
fixtures, crecting, painting grill work with one coat of anticorrosive
paint and polishing the still, hand rail with french polishing complete.
(PWDSR.2013/14,P.N.129,I.N.4)

5 Bd/U-4 P-538 Providing and fixing cast iron spiral staircase of two metre dia. With
galvanised iron central pipe shaft, cast iron steps, cast iron or wrought
iron balusters, mild steel or wrought iron rail, mild steel or cast iron
chequered plate landing, 1:3:6 cement concrete foundation and
painting in three coats of approved oil paint complete.
(PWDSR.2013/14,P.N.129,I.N.5)

6 Bd/C-2 P-275 Providing and fabricating structural steel works in rolled sections like
joists, channels, angles, tees etc. as per detailed designs and drawings
including fixing in position with connecting plates, braces and
welding, riverting, bolting as necessary including painting etc.
complete.(PWDSR.2013/14,P.N.129,I.N.6)

PAGE NO : 129
7 Bd/C-3 P-275 Providing structural steel work in rolled sections fixed with
connecting plates or angle cleats as in main and cross beams, hip and
jack rafters, purlins connecting to truss members and the like as per
detailed designs & drawings or as directed including cutting,
fabricating, hoisting, crecting, fixing in position, making riveted /
bolted/ welded connections and painting, scaffolding etc. complete.
(PWDSR.2013/14,P.N.130,I.N.7)

8 Bd/C-2 P-275 Providing and fabricating structural steel works with mild steel plates
as per detailed design and drawings including fixing in position and
welding, riveting, bolting as necessary including oil painting in three
coats etc. complete. (PWDSR.2013/14,P.N.129,I.N.8)
New Items
Note: The following all new items may be used on experimental basis
for one year only.
9 MORT & H Providing Fusion Bonded Epoxy Coating (FBEC) to reinforced bars of
1600 Edition ...... As per IS : 13620- 1993 specifictions for a thickness of 175
2001 micron Permissible variation of 50 micron including testing of coating
at plant extra cost for careful handling using PVC coating binding
wires instead of G.I wires to and from Plant) touching up the material
supplied repair work etc complete as per detailed specifications, (Lead
200 km from plant) etc complete.(PWDSR.2013/14,P.N.130,I.N.9)

a) 8 mm Diameter.
b) 10 MM Diameter.
c) 12 mm Diameter.
d) 16 mm Diameter.
e) 20mm Diameter.
f) 25 mm Diameter.
g) 28 mm Diamete.
PAGE NO : 130
BD-V : WATER SUPPLY AND SANITARY FITTINGS
1 Providing and laying G.I. pipe in trenches…… and having embossed
at every metre as ISI mark and name of the manufacturer with screwed
sockets, joints, and necessary galvanised iron fittings such as
backnuts, elbows, bends, tees, reducers, enlargers, plugs, etc.
including providing and applying two coats of oil paint with one coat
of primer and necessary excavation and backfilling complete including
removing existing pipe if necessary and conveying and stacking in
P.W.D. chowky or as directed. (PWDSR.2013/14,P.N.131,I.N.1)

Bd/V-5 P-551 a) 15 mm diameter heavy type having 21.30 mm outer dia. and 1.504
kg. per meter weight.
Bd/V-5 P-551 b) 20 mm diametre heavy type having 26.9 mm outer dia. and 1.953
kg. per meter weight.
Bd/V-5 P-551 c) 25 mm diameter heavy type having 33.7 mm outer dia. and 3.058
kg. per meter weight.
Bd/V-5 P-551 d) 32 mm diameter heavy type having 42.4 mm outer dia. and 3.937
kg. per meter weight.
Bd/V-5 P-551 e) 40 mm diameter heavy type having 48.3 mm outet dia. and 4.545
kg. per meter weight.
Bd/V-5 P-551 f) 50 mm diameter heavy type having 60.3 mm outer dia. and 6.329
kg. per meter weight.
Bd/V-5 P-551 g) 65 mm diameter heavy type having embosed at every metre as ISI
mark having 76.1 mm outer dia. and 8.065 kg. per meter weight.
Bd/V-5 P-551 h) 80 mm diameter heavy type galvanised iron pipe having embossed
at every metre as ISI mark having 88.90mm outer dia. and 10.309 kg.
per metre weight.
Bd/V-5 P-551 i) 100 mm diameter heavy type having embossed at every metre as ISI
mark having 114.3mm outer dia. and 15.152 kg. per meter weight.
PAGE NO : 131
PIPE LINES ON WALLS ETC.
2 Providing and fixing G.I. pipes…… and having embossed at every
metre as ISI mark and name of the manufacturer to walls, ceilings,
floors etc. with screwed sockets, backnuts, elbows, tees, reducers,
enlargers, plugs, clamps etc. including necessary drilling in holes in
walls / slabs etc. and remaking good the demolished portion to restore
the same in original condition neatly and applying primer and two
coats of oil painting including necessary scaffolding including
removing the existing pipe, if necessary and conveying and stacking
the same in P.W.D. chowky or as directed etc. complete.
(PWDSR.2013/14,P.N.132,I.N.2)

Bd/V-5 P-551 a) 15 mm diameter heavy type having 21.30 mm outer dia. and 1.504
kg. per meter weight.
Bd/V-5 P-551 b) 20 mm diametre heavy type having 26.9 mm outer dia. and 1.953
kg. per meter weight.
Bd/V-5 P-551 c) 25 mm diameter heavy type having 33.7 mm outer dia. and 3.058
kg. per meter weight.
Bd/V-5 P-551 d) 32 mm diameter heavy type having 42.4 mm outer dia. and 3.937
kg. per meter weight.
Bd/V-5 P-551 e) 40 mm diameter heavy type galvanised iron pipe having 48.3 mm
outer dia. and 4.545 kg. per meter weight.
Bd/V-5 P-551 f) 50 mm diameter heavy type having 60.3 mm outer dia. and 6.329
kg. per meter weight.
Bd/V-5 P-551 g) 100 mm diameter heavy type having 114.3 mm outer dia.and
15.152 kg. per meter weight.
PAGE NO : 132
3 Providing and fixing G.I.pipes……. and having embossed at every
metre as ISI mark and name of the manufacturer to walls, ceiling,
floors etc. with screwed sockets, backnuts, elbows, tees, reducers,
enlargers, plugs, clamps etc. including necessary drilling in holes in
walls / slabs etc. and remaking good the demolished portion to restore
the same in original condition neatly and applying primer and two
coats of oil painting including necessary scaffolding including
removing the existing pipe, if necessary and conveying and stacking
the same in P.W.D. chowky or as directed etc. complete.
(PWDSR.2013/14,P.N.133,I.N.3)

Bd/V-5 P-551 a) 15 mm diameter medium class having 21.30 mm outer dia. and
1.274 kg. per meter weight.
Bd/V-5 P-551 b) 20 mm diameter medium class having 26.9 mm outer dia. and 1.642
kg. per meter weight.
Bd/V-5 P-551 c) 25 mm diameter medium class having 33.7 mm outer dia. and 2.525
kg. per meter weight.
Bd/V-5 P-551 d) 32 mm diameter medium class having 42.4 mm outer dia. and 3.247
kg. per meter weight.
Bd/V-5 P-551 e) 40 mm diameter medium class having 48.3 mm outer dia. and 3.731
kg. per meter weight.
Bd/V-5 P-551 f) 50 mm diameter medium class having 60.3 mm outer dia. and 5.236
kg. per meter weight.
PAGE NO : 133
WATER METERS
4 Providing and fixing …… Water Meter bearing I.S.I. mark with non
return valve including starainer, sockets, union nut and construction of
brick mesonry chamber of requried and adequate size with cast iron
frame and mild steel hinged cover with locking arrangement and lock
etc. complete. (PWDSR.2013/14,P.N.134,I.N.4)

Bd/V-6 P-553 a) 15 mm dia


Bd/V-6 P-553 b) 20 mm dia.
Bd/V-6 P-553 c) 25 mm dia.
Bd/V-6 P-553 d) 40 mm dia.
Bd/V-6 P-553 e) 50 mm dia.
Bd/V-6 P-553 f) 80 mm dia.
Bd/V-6 P-553 g) 100 mm dia.
SCREW DOWN TAPS
5 Bd/V-8 P-554 Providing and fixing heavy type 12 mm dia. screw down bib/stop tap
of brass including socket, union nut etc. complete.
(PWDSR.2013/14,P.N.134,I.N.5)
6 Bd/V-8 P-554 Providing and fixng medium type 12 mm dia. screw down bib/stop tap
of brass including socket, union nut etc. complete.
(PWDSR.2013/14,P.N.134,I.N.6)
7 Bd/V-8 P-554 Providing and fixing cast iron 12 mm dia. screw down bib/stop tap
including socket, union nut etc. complete.
(PWDSR.2013/14,P.N.134,I.N.7)
PAGE NO : 134
WHEELED STOP TAP
8 Providing and fixing screw down….. Wheeled stop tap of gun metal
bearing I.S.I. mark including sockets, union nut complete.
(PWDSR.2013/14,P.N.135,I.N.8)
Bd/V-9 P-555 a) 15 mm dia.
Bd/V-9 P-555 b) 20 mm dia.
Bd/V-9 P-555 c) 25 mm dia.
Bd/V-9 P-555 d) 32 mm dia.
Bd/V-9 P-555 e) 40 mm dia.
Bd/V-9 P-555 f) 50 mm dia.
Bd/V-9 P-555 g) 65 mm dia.
Bd/V-9 P-555 h) 80 mm dia.
STOP TAP
9 Providing and fixng …… gun metal stop tap with cluth/wheel
including sockets/ union nut and brick mesonry chamber with cast iron
frame and mild steel hinged cover with locking arrangement and lock.
(PWDSR.2013/14,P.N.134,I.N.9)
Bd/V-10 P-555 a) 15 mm dia.

Bd/V-10 P-555 b) 20 mm dia.

Bd/V-10 P-555 c) 25 mm dia.

10 Bd/V-12 P-556 Providing and fixing 10 cm dia. Chromium plated brass shower rose
to 15 mm dia. Supply pipe including necessary G.I. bend and socket
complete.(PWDSR.2013/14,P.N.135,I.N.10)
11 Bd/V-19 P-559 Providing and fixing 45 cm wide steel ladder of 40 mm x 6 mm mild
steel flat stringers and steps of 18 mm diameter mild steel bar
including fixing it in 1:2:4 cement concrete block 60 cm x 30 cm x 30
cm and painting the ladder. (PWDSR.2013/14,P.N.135,I.N.11)
PAGE NO : 135
12 Bd/V-20 P-559 Providing and fixing Indian type white glazed earthenware 580mm
Water Closet Pan incliding "P" trap, white earthenware foot rests, Cast
iron soil and vent pipes upto the outside face of the wall including 100
mm diameter cast iron plug bend, cement concrete bedding, 10 litres
white H.D.P. flushing cistern with fittings, inlet pipe with stop tap, 32
mm diameter galvanised iron flush pipe heavy type with fittings and
clamps, painting to exposed pipes and cutting and making good the
walls and floors (Excluding water proofing with brick bat coba).
(PWDSR.2014/13,P.N.136,I.N.12)

13 Bd/V-21 P-561 Providing and fixing European type white glazed earthenware 580mm
Water Closet Pan with mahogany seat and lid with chromium plated
brass hinges and rubber buffers including cast iron soil and vent pipes
upto the outside face of wall and 100 mm diameter cast iron plug
bend, 10 litres white H.D.P. flushing cistern with fittings, pipes and
stop tap, 32 mm dia galvanised iron heavy type flush pipe with fittings
and clamps painting to exposed pipes and cutting and making good
wall and floors. (PWDSR.2013/14,P.N.136,I.N.13)

14 Bd/V-22 P-562 Providing and fixing European type white glazed earthenware 580mm
Water Closet Pan with polished mahogany seat and lid with chromium
plated brass hinges and rubber buffers including cast iron soil and vent
pipes upto the outside face of wall and 100 mm. diameter cast iron
plug bend, 10 litres pressed steel enameled low level flushing cistern
with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 40
mm dia enameled bend and rubber, 20 mm dia. galvanised iron
overflow pipe with specials and mosquitoproof coupling chromium
plated working handles, painting of exposed pipes and cutting and
making good walls and floors.(PWDSR.2013/14,P.N.136,I.N.14)
15 Bd/V-55 P-562 Providing and fixing European type white galzed earthenware 580mm
Water Closet Pan with mahogany seat and lid with chromium plated
brass hinges and rubber buffers including cast iron soil and vent pipes
upto the outside face of wall and 100 mm diameter cast iron plug
bend, 10 litres white glazed earthenware vitreous china ware low level
flushing cistern with syphonic valveless fittings and flush bend and
inlet pipe with stop tap, brackets for fixing the cistern, 40 mm dia
galvanised iron overflow pipe with specials and mosquito proof
coupling, chromium plated working handles, painting of the exposed
pipes and cutting and making good walls and floors.
(PWDSR.2013/14,P.N.136,I.N.15)

PAGE NO : 136
16 Bd/V-22 P-562 Providing and fixing European type white glazed earthenware 580mm
coupled closet syphonic trap with syphonic low level white glazed 10
litres cistern with black bakelite seat and lid with chromium plated
brass hinges including cast iron soil and vent pipes upto the outside
face of the wall including 100 mm diameter cast iron plug bend, inlet
pipe, stop tap etc. all fittings, cutting and making good walls and
floors complete. (PWDSR.2013/14,P.N.137,I.N.16)

17 Bd/V-22 P-562 Providing and fixing European type coloured glazed earthenware
580mm coupled closet syphonic trap with syphonic low level white
glazed 10 litres cistern with black backlite seat and lid with chromium
plated brass hinges including cast iron soil and vent pipes upto the
outside face of the wall including 100 mm diameter cast iron plug
bend, inlet pipe, stop tap etc. all fittings, cutting and making good
walls and floors complete. (PWDSR.2013/14,P.N.137,I.N.17)

18 Providing and fixing Orrisa type …… glazed earthenware 580 mm x


450 mm water closet pan including trap, cast iron soil and vent pipes
upto the outside face of the wall including 100 mm. diameter cast iron
plug bend, cement concrete bedding, 10 litres capacity H.D.P.E.
flushing cistern with fittings, inlet pipe with stop tap, brackets, 32 mm.
diameter galvanised iron heavy type flush pipe with fittings and
clamps, painting to exposed pipes and cutting and making good the
walls and floors etc. complete. (Excluding water proofing with brick
bat coba). (PWDSR.2012/13,P.N.137,I.N.18)

Bd/V-20 P-559 a) white

Bd/V-20 P-559 b) coloured

URINALS
19 Providing and fixing white glazed earthenware …… type urinal with
white H.D.P.E. flushing cistern of 5 litres capacity with fittings, inlet
pipe and stop tap, brackets for fixing the cistern, 32 mm diameter
galvanised iron heavy type flush pipe with fittings and flushing
spreader arrangement etc. complete.
(PWDSR.2013/14,P.N.137,I.N.19)
Bd/V-23 P-562 a) full stall

Bd/V-23 P-562 b) half stall

PAGE NO : 137
20 Providing and fixing …… White glazed earthenware ……. type urinal
with white H.D.P.E. flushing cistern of 5 litres capacity with fittings,
inlet pipe and stop tap, brackets for fixing the cistern, 32 mm diameter
galvanised iron heavy type flush pipe with fittings and spreader
arrangement etc. complete. (PWDSR.2013/14,P.N.138,I.N.20)

Bd/V-25 P-563 a) group of 2 ……. full stall

Bd/V-25 P-563 b) group of 2 …… half stall

Bd/V-25 P-563 c) group of 3 …… full stall

Bd/V-25 P-563 d) group of 3 …… half stall

Bd/V-25 P-563 e) group of 4 ….. full stall

Bd/V-25 P-563 f) group of 4 ….. half stall

21 Providing and fixing White glazed earthenware …… type urinal with


white H.D.P.E. flushing cistern of 5 litres capacity with fittings, inlet
pipe and stop tap, brackets for fixing the cistern , 32 mm diameter
galvanised iron heavy type flush pipe with fittings and spreader
arrangement etc. complete. (PWDSR.2013/14,P.N.138,I.N.21)

Bd/V-26 P-564 a) lipped flat back

Bd/V-28 P-564 b) group of two lipped flat back

Bd/V-28 P-564 c) group of three lipped flat back

Bd/V-28 P-564 d) group of four lipped flat back

22 Bd/V-29 P-565 Providing and laying 100 mm dia. half round white glazed
earthenware pipes in 1:5:10 cement concrete including bends, giving
necessary slope, pointing etc. complete.
(PWDSR.2013/14,P.N.138,I.N.22)
PAGE NO : 138
23 Providing and fixing ……. size including one cold water pillar tap,
brackets, rubber plugs and brass chain, stop tap and necessary pipe
connection including bottle trap and polyethylene waste water pipe
upto the out side face of the wall, making good the damaged surface,
testing etc. complete. (PWDSR.2013/14,P.N.139,I.N.23)
Bd/V-30 P-565 a) white glazed earthenware wash hand basin of 55 cm x 40 cm

Bd/V-30 P-565 b) coloured glazed earthenware wash hand basin of 55 x 40 cm

Bd/V-30 P-565 c) white glazed earthenware wash hand basin of 63 cm x 45 cm

24 Providing and fixing ……. size including one cold water pillar tap,
brackets, rubber plugs and brass chain, stop tap and necessary pipe
connection including bottle trap and polyethylene waste water pipe
upto the out side face of the wall, making good the damaged surface,
testing etc. complete. (PWDSR.2013/14,P.N.139,I.N.24)

Bd/V-31 P-566 a) white glazed earthenware sink 600 mm x 200 mm x 450 mm

Bd/V-31 P-566 b) coloured glazed earthenware sink 600 mm x 200 mm x 450 mm

Bd/V-31 P-566 c) white glazed earthenware sink 450 mm x 300 mm x 180 mm

25 Providing and fixing Steel sink of size 60 x 45 x 25 cm including all


connections of G.I. supply and UPVC waste pipe and trap upto outside
face of wall, could water chromium plated screw down bib tap, rolled
steel or C.I. brackets, rubber plug and stop tap, making good the
damaged surface, chromium plated bottle trap testing etc. complete.
(Prior approval of sample and brand by Executive Engineer is
necessary before use). (PWDSR.2013/14,P.N.139,I.N.25)

Spec: (As directed by Engineer in charge)


26 Bd/V-32 P-567 Providing and fixing 10 cm cast iron Nahani Trap with fixed cast iron
grating, cast iron plug bend and piece of cast iron pipe upto plug bend
etc. complete.(PWDSR.2013/14,P.N.139,I.N.26)
PAGE NO : 139
Note :- Following item No. 27 to 29 shall only be ued after the prior
inspection of site and issue of specific order by superintending
Engineer.
27 Bd/V-33 P-567 Providing and fixing ISI 1719/2002 grade 100 mm dia. Cast iron Rain
Water pipe with lugs including rain water receiving recess with cast
iron grating plug bend, necessary fittings such as offsets, shoe
including filling joints with spun yarn soaked in bitumen and cement
mortar in 1:2 proportion, fixing 30 x 5 mm plate and 8 mm square rod
with G.I. clam with washer as per design, drawing and as directed to
keep pipe 50 mm away from wall including testing, cement concrete
1:2:4 blocks of 30 cm x 30 cm x 30 cm in size including necessary
scaffolding and painting the exposed faces with one coat of red lead
oil paint and two coats of oil paint and conveying and stacking in
P.W.D. chowky or as directed by Engineer-in-charge.
(PWDSR.2013/14,P.N.140,I.N.27)
28 Providing and fixing ISI 1729/2002 grade …… Cast Iron Soil Pipes
With lugs including plug bend necessary fittings such as bends, tees,
single junction, double junction, slotted vent, offsets on wall or into
the ground including filling joints with cement mortar 1:2 proporation
fixing on wall by means of galvanised M.S. bracket of 30 x 5 mm
plate and 8 mm square rod with G.I. clamp with washer as per design,
drawing and as directed to keep pipe 50 mm away from wall including
necessary scaffolding and painting the exposed faces with one coat of
red lead oil paint and two coats of oil paint including removing the
existing pipe if necessary and conveying and stacking in PWD
Chowky or as directed by Engineer-in-charge.
(PWDSR.2013/14,P.N.140,I.N.28)

Bd/V-35 P-570 a) 100 mm dia

Bd/V-35 P-570 b) 150 mm dia

PAGE NO : 140
29 Providing and fixing ISI 1729/2002 grade ….. Cast Iron Waste Water
Pipe with lugs necessary fittings such as bends, tees, single junction,
double junction, slotted vent, offsets on wall or into the ground
including filling joints with cement mortar 1:2 proportion fixing on
wall by means by galvanised M.S. bracket of 30 x 5 mm plate and 8
mm square rod with G.I. clamp with washer as per design drawings
and as directed to keep pipe 50 mm away from wall including
necessary scaffolding and painting the exposed fees with one coat of
red lead oil paint and two coats oil paint including removing the
existing pipe if necessary and conveying and stacking in PWD
Chowky or as directed by Engineer-in-Charge.
(PWDSR.2013/14,P.N.141,I.N.29)

Bd/V-35 P-570 a) 75 mm dia

Bd/V-35 P-570 b) 100 mm dia

30 Bd/V-33 (b) Providing and fixing 0.794 mm (22 guage) thickness galvanised iron
P-568 plain sheet half round rain water gutter including fittings such as outlet
angles and stop ends with brackets fixed with screws to rafters/ eaves
boards etc. complete including scaffolding etc. complete as directed.
(PWDSR.2013/14,P.N.141,I.N.30)
31 Providing and fixing …… Asbestos Cement Rain Water Pipes
including rain water receiving recess, caste iron grating, necessary
asbestos cement fittings such as bends, shoes including fixing pipes on
walls with wooden holders by means of mild steel strip clamps 32 x
1.5 mm size including necessary scaffolding, cement concrete 1:2:4
blocks of 30 cm x 30 cm size and painting the exposed faces with two
coats of paint complete including removing the existing pipe if
necessary and conveying and stacking in P.W.D. chowky or as
directed. (PWDSR.2013/14,P.N.141,I.N.31)

Bd/V-34 P-569 a) 100 mm dia

Bd/V-34 P-569 b) 150 mm dia

PAGE NO : 141
32 Providing and fixing ….. Asbestos Cement …… including necessary
fittings such as bends, tees, single junctions, double junction, slotted
vent, offsets on walls or in the ground including filling joints with
cement mortar 1:2 including fixing the pipe on walls with wooden
holders/battens by means of mild steel strip clamps 32 x 1.5 mm size
including painting the exposed pipes with two coats of waterproof
cement paint and scaffolding complete.
(PWDSR.2013/14,P.N.142,I.N.32)

Bd/V-36 P-571 a) 100 mm dia …… Soil/ Waste Water Pipes

Bd/V-36 P-571 b) 75 mm dia ….. Waste Water Pipes

Bd/V-36 P-571 c) 63.5 mm dia …. Vent Pipe

33 Providing and fixing P.V.C. Rain Water Pipes ….. and having wall
thickness of 2.2 to 2.7 mm conforming to I.S. 13592-1992 including
proper rain water receiving recess with P.V.C. plug bend, necessary
fittings such as offsets, shoes including fixing the pipe on wall using
approved wooden cleats projecting 25 mm to 40 mm from face of wall
& fixing with clips of approved quality & number, filling the joints
using rubber gasket with solvent cement and properly resting the shoe
of pipes on C.C. or masonry blocks, including necessary scaffolding,
and maintenance for 3 years for any leakages or dislocation of pipes.
All the PVC fittings and additional two piece socket clips shall be got
approved from Engineer in charge etc. complete. (The contractors
shall give 3 years guarantee bond for payment).
(PWDSR.2013/14,P.N.142,I.N.33)

Bd/V-33 P-575 a) 110 mm outer dia.

Bd/V-33 P-575 b) 75 mm outer dia

PAGE NO : 142
34 Providing and fixing P.V.C.Soil/Waste Water Pipes …… and having
wall thickness of 3.2 to 3.8 mm conforming to I.S. 13592-1992
including P.V.C. plug bend, necessary fittings such as bend, tees,
single junction, double junction, slotted vent offsets on walls or in the
ground including fixing the pipe on wall using approved wooden
cleats projecting 25 mm to 40 mm from face of wall and fixing with
clips of approved quality and number, filling the joints using rubber
gasket with solvent cement including necessary scaffolding, and
maintenance for 3 years for any leakages or dislocation of pipes. All
the PVC fittings and additional two piece socket clips shall be got
approved from Engineer in charge etc. complete. (The contractors
shall give 3 years guarantee bond for payment).
(PWDSR.2013/14,P.N.143,I.N.34)

Bd//V-35 P- a) 110 mm outer dia.


570
Bd/V-35 P-570 b) 75 mm outer dia.

35 Bd/V-32 P-567 Providing and fixing 10 cm P.V.C. Nahani Trap fixed with P.V.C.
grating, P.V.C. plug bend and piece of P.V.C. pipe upto plug bend,
scaffolding etc. complete. (PWDSR.2013/14,P.N.143,I.N.35)
36 Bd/V-38 P-572 Providing and fixing 15 cm x 10 cm Salt Glazed Stoneware Gully
Trap In cement concrete 1:4:8 outside the building including
connecting to salt glazed stoneware pipe, brick masonry chamber with
cast iron lid grating for the gully trap etc. complete as directed.
(PWDSR.2013/14,P.N.143,I.N.36)

37 Providing and laying ….. Salt Glazed Stoneware pipe including


fittings such as bends, tees, single junctions,double junctions, laying,
jointing (excluding excavation and refilling the trenches) etc. complete
as directed.(PWDSR.2013/14,P.N.143,I.N.37)
Bd/V-39 P-573 a) 100 mm dia.

Bd/V-39 P-573 b) 150 mm dia.

Bd/V-39 P-573 c) 225 mm dia.

PAGE NO : 143
38 Providing and constructing Brick Masonry Inspection Chamber ……
in depth including necessary excavatiom, cement concrete 1:4:8
foundation, cement concrete 1:2:4, 23 cm thick channels, brick
masonry, plastering from inside and outside as requried in cement
mortar 1:3 and airtight cast iron heavy type lid (1 CWT weight) with
frame fixed in cement concrete 1:2:4 etc. complete as directed.
(PWDSR.2013/14,P.N.144,I.N.38)

Bd/V-43 P-574 a) 60 cm x 45 cm and 45 cm to 90 cm in depth.


Bd/V-43 P-575 b) 90 cm x 45 cm and 90 cm to 150 cm in depth.

39 Bd/V-44 P-575 Providing and constructing Brick Masonry Intercepting Trap Chamber
(sewer trap) of 90 cm x 45 cm including necessary excavation, cement
concrete 1:4:8 foundation, cement concrete 1:2:4 channels/ half round
glazed stoneware pipe channel, salt glazed stoneware intercepting trap
with rodding pipe set in cement concrete 1:4:8, brick masonry,
plastering inside and outside as requried, cast iron heavy lid (1.5 CWT
weight) with frame fixed in cement concrete 1:2:4 etc. complete as
directed.(PWDSR.2013/14,P.N.144,I.N.39)

40 Providing and constructing Circular Manhole 45 cm dia. at top 90 cm


at bottom upto 1.80 metre to 2.70 metre depth including excavation,
laying 1:4:8 cement concrete bedding, 15 cm thick burnt brick
masonry with 1:1 cement mortar plaster 25 mm thick inside and
outside 20 mm (1:3), cast iron heavy type cover with ring 125 kg in
weight, refilling etc. as per municipal requirement.
(PWDSR.2013/14,P.N.144,I.N.40)

Spec: (As directed by Engineer in charge)


41 Providing and constructing Surface Drain 300 mm (12") wide and 450
mm (18") depth (average) with 230 mm (9") burnt brick masonry
plastered on both sides with 20 mm (3/4") thick in cement mortar 1:3
including 300 mm (12") dia. Glazed stoneware channel at bottom
fixed in cement concrete 1:4:8 bedding 900 mm x 150 mm (3'-0" x 0'-
6") giving requried slope, curing, necessary excavation, refilling the
sides etc. complete. (PWDSR.2013/14,P.N.144,I.N.41)

Spec: (As directed by Engineer in charge)


PAGE NO : 144
42 Providing and fixing 12 mm Chromium Plated 4" long pillar type cock
with deluxe knob for Wash Hand Basin or sink etc. complete.
(PWDSR.2013/14,P.N.145,I.N.42)
Spec: (As directed by Engineer in charge)
43 Providing and fixing …… Ball Cock medium type with P.V.C. float
including sockets and necessary fittings and tested as per municipal
requirement etc.(PWDSR.2013/14,P.N.145,I.N.43)
Bd/V-18 P-558 a) 50 mm dia.

Bd/V-18 P-558 b) 40 mm dia.

Bd/V-18 P-558 c) 25 mm dia.

Bd/V-18 P-558 d) 20 mm dia.

Bd/V-18 P-558 e) 15 mm dia.


44 Providing and fixing Chromium Plated Alluminium Towel Rails 16
mm (5/8") dia. of requried length and approved quality fixed on teak
wood plate 75 mm x 10 mm (3" x 3/8") including providing teak wood
block in the brick work etc. (PWDSR.2013/14,P.N.145,I.N.44)

Spec: (As directed by Engineer in charge)


45 Providing and fixing Mirrors of approved Indian quality, copper plated
with 10 mm (3/8") thick ply wood backing, in the masonry etc.
complete. (PWDSR.2013/14,P.N.145,I.N.45)
Spec: (As directed by Engineer in charge)
46 Providing and fixing Chromium Plated Peg Rack (with four pegs)
fixed on 75 mm x 10 mm (3" x 3/8") varnished teak wood plate 910
mm (3'-0") long including fixing teak wood blocks in masonry etc.
complete.(PWDSR.2013/14,P.N.145,I.N.46)
Spec: (As directed by Engineer in charge)
47 Providing and fixing Chromium Plated Peg Rack (with three pegs)
fixed on 75 mm x 10 mm (3" x 3/8") varnished teak wood plate 750
mm (2'-6") long including fixing teak wood blocks in masonry etc.
complete.(PWDSR.2013/14,P.N.145,I.N.47)
Spec: (As directed by Engineer in charge)
PAGE NO : 145
48 Providing and fixing Chromium Plated Towel Rail 750 mm (2'-6")
long, 20 mm (3/4") dia. and of approved quality fixed on chromium
plated bracket including providing teak wood gutties in masonry etc.
complete.(PWDSR.2013/14,P.N.146,I.N.48)
Spec: (As directed by Engineer in charge)
49 Providing and fixing Glass Shelf 125 mm (5") wide and 610 mm (24")
long with necessary chromium plated brackets, providing teak wood
gutties etc. complete. (PWDSR.2013/14,P.N.146,I.N.49)
Spec: (As directed by Engineer in charge)
50 Providing and fixing H.D.P.E. Flushing Tank of approved quality,
including removing the existing tank and disconnecting and
reconnecting to water supply and drainage pipes and making good the
deficiencies etc. complete. (PWDSR.2013/14,P.N.146,I.N.50)
Spec: (As directed by Engineer in charge)
51 Providing and fixing Asbestos Cement Slotted Cowl Dome…….
diameter in soil pipe with neat cement etc. complete.
(PWDSR.2013/14,P.N.146,I.N.50)
Spec: (As directed by Engineer in charge)
a) 100 mm diameter
b) 175 mm diameter
52 Providing and fixing …… for Wash Hand Basin of approved size,
make and quality etc. complete. (PWDSR.2013/14,P.N.146,I.N.52)

(As directed by Engineer in charge)


a) white glazed pedestal
b) coloured glazed pedestal
53 Disconnecting, shifting, turing and removing Water Tank for repairs
and testing after repairs and fixing in position with all connection etc.
complete.(PWDSR.2013/14,P.N.146,I.N.53)
Spec: (As directed by Engineer in charge)
54 Supplying 3.15 mm thick Mild Steel Plate including cutting to the
requried size as directed etc. complete.
(PWDSR.2013/14,P.N.146,I.N.54)
Spec: (As directed by Engineer in charge)
55 Fixing and Mild Steel Plates at proper place by welding including
cutting and removing the existing mild steel plate if necessary etc.
complete.(PWDSR.2013/14,P.N.146,I.N.55)
Spec: (As directed by Engineer in charge)
PAGE NO : 146
56 Providing and fixing in position 25 mm dia. Galvanised Iron Water
Spout of requried length in balconies etc. including necessary bending
and painting in three coats and making good the damages etc.
complete.(PWDSR.2013/14,P.N.147,I.N.56)
Spec: (As directed by Engineer in charge)
57 Renewing Indian type White Glazed Earthenware 580 mm W.C. pan
with "P" trap including cement concrete or lime concrete bedding and
making good damages, making connection to water supply and
drainage pipes and making good the deficiencies, if any.
(PWDSR.2012/13,P.N.147,I.N.57)

Spec: (As directed by Engineer in charge)


58 Removing old pan and fixing New White Galzed Wash Hand Basin 55
x 40 cm (22" x 16") including removing existing one and
disconnecting and reconnecting the existing accessories and making
good the damages and deficiencies, if any etc. complete.
(PWDSR.2013/14,P.N.147,I.N.58)

Spec: (As directed by Engineer in charge)


59 Providing and fixing White Fibre Glass Bath Tub 1676 mm x 76 mm
(5'-6" x 2'-6") with front and two side panels including chromium
plated over flow pipe and waste coupling, chromium plated plug chain
including fixing on site etc. complete .
(PWDSR.2013/14,P.N.147,I.N.59)

Spec: (As directed by Engineer in charge)


60 Providing and fixing Coloured Fibre Glass Bath Tub 1676 mm x 76
mm (5'-6" x 2'-6" with front and two side panels including chromium
plated over flow pipe and waste coupling, chromium plated plug chain
including fixing on site etc. complete.
(PWDSR.2013/14,P.N.147,I.N.60)

Spec: (As directed by Engineer in charge)


61 Providing and fixing 40 mm (1 1/2") Hot and Cold Bath Mixer of
approved quality and make with crutch including one metre long
telephone shower etc. complete as directed.
(PWDSR.2013/14,P.N.147,I.N.61)
Spec: (As directed by Engineer in charge)
62 Bd/V-45 P-575 Providing and fixing Hume Pipe Septic Tank 1200 mm dia. With vent
pipe and cowl including necessary excavation and laying in position
including providing soak pit of requried size with brick bats etc.
complete.(PWDSR.2013/14,P.N.147,I.N.62)
PAGE NO : 147
63 Providing and fixing High Density polyethylene UV stabilized water
stroage tank including conveying and hoisting in position confirming
to I.S. 12701, with all leads and lifts of making necessary connection,
testing and all requried accessories including providing steel ladder as
per M.C.G.M. requirement etc. complete (Prior approval of sample by
Executive Engineer is necessary before use).
(PWDSR.2013/14,P.N.148,I.N.63)

Spec: (As directed by Engineer in charge)


64 Providing and laying Cement Concrete Pipe of IS NP2 class of
requried diameter in proper line, level and slope including providing,
fixing collars in cement mortar 1:2 complete including loading and
unloading pipes of …… etc.complete.
(PWDSR.2013/14,P.N.148,I.N.64)

Spec: (As directed by Engineer in charge)


a) 150 mm diameter
b) 225 mm diameter
65 Providing and fixing …… Centrifugal Cast (spun) C.I. …… I.S.
3989/1984 with necessary fixtures and fittings such as bends, tees,
single junction, double junction, slotted vent, offsets on walls or in the
ground including filling joints with cement and fixing the pipe on
walls by means of suitable M.S. bracket to keep pipe 25-40 mm away
from wall including existing pipe if necessary and conveying and
stacking in P.W.D. chowky or as directed.
(PWDSR.2013/14,P.N.148,I.N.65)

Spec: (As directed by Engineer in charge)


a) 75 mm dia. ….. Soil/Waste water pipe
b) 100 mm dia. …. Soil/Waste water pipe
c) 150 mm dia. ….. Soil/Waste water pipe
66 Bd/W-8 P-587 Removing urinal pans or wash hand basins with frame including
disconnecting the sanitary and water supply connections, removing the
same carefully and stacking the serviceable materials as and where
directed including throwing the unserviceable materials outside.
(PWDSR.2013/14,P.N.148,I.N.66)

PAGE NO : 148
67 Bd/W-8 P-587 Removing W.C. pans including disconnecting the sanitary and water
supply connections, removing and breaking flooring and bed concrete
around pans and removing pan carefully and throwing out the refusal
outside etc. complete. (PWDSR.2013/14,P.N.149,I.N.67)

Note : Following items should not be executed before prior approval


of Superintending Engineer.
68 Providing and laying in trenches …… RIGID PVC ASTM Threaded
heavy pressure pipes (Blue) Schedule 80 as per I.S. 4985-2000 and
name of manufacturer with G.I. Screwed sockets, joints and necessary
G.I, fittings such as backnuts, elbows, bends, tees, reducers, enlargers,
plugs etc. and testing with a hydraulic pump for a pressure of 7 kg./sq.
cm. or as mentioned in M.C.G.M. Bye-Laws including necessary
excavation and back filling complete including removing existing
pipes, if necessary and conveying and stacking in P.W.D. chowky etc.
complete.(PWDSR.2013/14,P.N.149,I.N.68)

Spec: (As directed by Engineer in charge)


a) 63 mm outer diameter having wall thickness 5.54 mm to 6.20 mm
b) 90 mm outer diamter having wall thickness 7.62 mm to 8.53 mm
c) 110 mm outer diameter having wall thickness 8.56 mm to 9.58 mm

69 Providing and fixing ……. 2.50 kg./Rmt. As per I.S. 4985-2000


having thickness …… for sewerage line including fittings such as
bends, tees, single junction, double junction, laying, jointing with
solvent jointing (excluding excavation and refilling the trenches) etc.
complete.(PWDSR.2013/14,P.N.149,I.N.69)

Spec: (As directed by Engineer in charge)


a) 75 mm diameters selfit P.V.C. pipe….. 1.60 mm to 2.00 mm
b) 110 mm diameters selfit P.V.C. pipe ….. 2.30 mm to 2.80 mm
70 Providing and fixing 15 mm diameter Standard Bib Cock P.V.C.
polymer scratch resistant, anti-static with guarantee against any
manufacturing defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.149,I.N.70)
Spec: (As directed by Engineer in charge)
PAGE NO : 149
71 Providing and fixing 15 mm diameter Standard Stop Cock (Male
thread) P.V.C. polymer scratch resistant, anti-state with guarantee
against any manufacturing defect including socket, union nuts etc.
complete.(PWDSR.2013/14,P.N.150,I.N.71)
Spec: (As directed by Engineer in charge)
72 Providing and fixing 15 mm diameter Bib Cock long body with flange
P.V.C. polymer scratch resistant, anti-static with guarantee against any
manufacturing defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.72)
Spec: (As directed by Engineer in charge)
73 Providing and fixing 32 mm diameter Bottle trap P.V.C. polymer
scratch resistant, anti-static with guarantee against any manufacturing
defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.73)
Spec: (As directed by Engineer in charge)
74 Providing and fixing 15 mm diameter Piller cock P.V.C. polymer
scratch resistant, antistatic with guarantee against any manufacturing
defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.74)
Spec: (As directed by Engineer in charge)
75 Providing and fixing 15 mm diameter Angle cock with flange P.V.C.
polymer scratch resistant, anti-static with guarantee against any
manufacturing defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.75)
Spec: (As directed by Engineer in charge)
76 Providing and fixing 15 mm diameter Urinal cock P.V.C. polymer
scratch resistant, anti-static with guarantee against any manufacturing
defect including socket. union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.76)
Spec: (As directed by Engineer in charge)
77 Providing and fixing 15 mm diameter Urinal Spreader P.V.C. polymer
scratch resistant, anti-static with guarantee against any manufacturing
defect including socket, union nuts etc. complete.
(PWDSR.2013/14,P.N.150,I.N.77)
Spec: (As directed by Engineer in charge)
PAGE NO : 150
78 Providing and fixing Steel Sink of size 60 x 45 x 25 cm to the kitchen
platform including UPVC waste coupling pipe and coupling, making
good the damaged surface etc. complete.
(PWDSR.2013/14,P.N.151,I.N.78)
Note : Prior approval of sample and brand by Executive Engineer is
necessary before use.
Spec: (As directed by Engineer in charge)
79 Removing Old Pan and fixing New Orrisa type white glazed
earthenware 580 x 45 mm water closed pan including 100 mm
diameter cast iron soil and vent pipes upto the outside of the wall
including C.I. plug bend, cement mortar bedding of fixing
waterproofing coba and making good the wall and floors
etc.complete. (Excluding water proofing with brick bat coba).
(PWDSR.2013/14,P.N.151,I.N.79)

Spec: (As directed by Engineer in charge)


80 Providing and constructing kitchen Platform in granite slab of
approved type and design with 0.80 metre wide and 0.75 meter height
with kadappa supports. The gap in between supports to be filled with
cement mortar 40 mm thick kadappa below the granite top and all
vertical kadappa support including front granite patti supports finished
with the granite top on it. (without sink) .
(PWDSR.20123/14,P.N.151,I.N.80)

Spec: (As directed by Engineer in charge)


81 Cleaning existing water tank with cold and hot water by jetting
pressure machine, using SAF-H-20 (Ayurvedic anti bacteria solution)
or equivalent wiping all sides with duster including using ultra violet
rays for disinfections cleaning etc. complete.
(PWDSR.2013/14,P.N.151,I.N.81)

Spec: (As directed by Engineer in charge)


82 Providing and fixing long body water spout of decorative stealth series
ivory gold or chromium plated with flange for bath tub of approved
Jaguar or equivalent make including necessary washer, taplon tape etc.
complete.(PWDSR.2013/14,P.N.151,I.N.82)
Spec: (As directed by Engineer in charge)
83 Providing and fixing decorative stealth series ivory gold or chromium
plated Overhead Shower of approved jaguar or equivalent make with
flang, necessary angular connecting rod, union nut, washers, taplon
tape etc. complete. (PWDSR.2012/13,P.N.1,I.N.83)
Spec: (As directed by Engineer in charge)
PAGE NO : 151
84 Providing and fixing single lever high flow concealed diverter
decorative stealth series ivory gold or chromium plated with flange
and revolving joint with hot and cold water arrangement of approved
Jaguar or equivalent make including necessary washer taplon tape etc.
complete. (PWDSR.2013/14,P.N.152,I.N.84)

Spec: (As directed by Engineer in charge)


85 Providing and fixing stealth faucet jet spray of approved Jaguar or
equivalent make including necessary socket/union etc. complete as
dirtected.(PWDSR.2013/14,P.N.152,I.N.85)
Spec: (As directed by Engineer in charge)
86 Providing and laying in trenches 160 mm nominal outer diameter
UPVC water pipe including all necessary fittings such as bends, tee,
single/double junction, slotted vents, offsets on wall, volve including
necessary scaffolding etc. complete.
(PWDSR.2013/14,P.N.152,I.N.86)

Spec: (As directed by Engineer in charge)


87 Providing and fixing leak proof and frost proof 3-Layer PP-R
(Polypropylene random copolymer) Pipes UV Stabilized and anti
microbial fusion welded, of PN-16 …… having wall thickness ……
having thermal stability for Hot and Cold Water Supply as per IS:
15801 including all PP-R plain and brass threaded Polyproylene
random fittings including fixing the pipe with clamps at 1.00 m
spacing having embossed at every metre as ISI make and name of
manufacturer to walls ceilings, floors, including necessary drilling in
holes in walls/ slabs etc. and remaking good the demolished portion to
restore the same in original condition neatly including necessary
scaffolding and removing existing pipe if necessary and conveying
and stacking the same in PWD chowky etc. complete. Low melt flow
rate, high molecular weight and Good flexibility. This includes testing
of joints complete as per direction of engineer in charge.
(PWDSR.2013/14,P.N.152,I.N.87)

Spec: (As directed by Engineer in charge)


a) 20 mm outer dia……. 2.8 mm
b) 25 mm outer dia …….3.5 mm
c) 32 mm outer dia……. 4.4 mm
d) 40 mm outer dia……. 5.5 mm
e) 50 mm outer dia……..6.9 mm
PAGE NO : 152
88 Providing and fixing 20 mm diameter SFMC Brand PP-R or
equivalent Ball Valve (Light Weight Brass) fusion welded, Having
thermal stability for hot & cold Water Supply and testing of joints
complete as per direction of Engineer in charge.
(PWDSR.2013/14,P.N.153,I.N.88)

Spec: (As directed by Engineer in charge)


89 Providing and fixing leakproof and frost proof ASTMD (UPVC) Pipes
of ….. having a wall thickness ……. Schedule 80 pipes (pressure
rating) for normal water supply etc. complete.
(PWDSR.2013/14,P.N.153,I.N.89)
Spec: (As directed by Engineer in charge)
a) 15 mm dia …… 3.73 mm
b) 20 mm dia …… 3.91 mm
c) 25 mm dia …… 4.55 mm
d) 32 mm dia …… 4.85 mm
e) 40 mm dia ……. 5.08 mm
f) 50 mm dia …….. 5.54 mm
90 Providing and constructing Ductile Iron Circular Manhole 45 cm dia.
at top 90 cm at bottom up to 1.80 metre to 2.70 meter depth including
excavation, laying 1:4:8 cement concrete beding, 15 cm thick burnt
brick masonry with 1:1 cement mortar plater 25 mm thick inside and
outside 20 mm (1:3), ductile iron heavy type cover with ring 125 kg.
in weight, High strength, More life and Durability, Good Antiskid,
Grip, Suitable to Heavy theatric loading, Light weight casting after
cost benefits for Transportation. Refilling etc. as per requriment.
(PWDSR.2013/14,P.N.153,I.N.90)

Spec: (As directed by Engineer in charge)


91 Supply of NECO Brand Ductile Iron Manhole Covers. Granting and
Granting with frame of various sizes, weight and types and load
bearing capacity as per EN-124, including of all taxes in BMC limits.
(PWDSR.2013/14,P.N.153,I.N.91)
Spec: (As directed by Engineer in charge)
PAGE NO : 153
92 Providing and constructing Manhole 60 cm dia. at top 90 cm at
bottom up to 1.80 meter to 2.70 meter depth including excavation,
laying 1:4:8 cement concrete bedding, 15 cm thick burnt brick
masonry with 1:1 cement mortar plater 25 mm thick inside and outside
20 mm (1:3), including supplying Composite Resin Manhole cover
and frame of appropriate size and having load cpacity of 20 Tonnes
confirming to EN-124:1994 Product shall have top abrassion resistant
layer of decorative gray granite finish confirming to test performed as
per IS- 15658:2006. It shall also confirm Permanent Set criterion as
per EN-124. Product should be tested in NABL accredited test lab for
load capacity and permanet set.(PWDSR.2013/14,P.N.154,I.N.92)

93 Providing and constructing Manhole 60 cm dia. At top 90 cm at


bottom up to 1.80 meter to 2.70 meter depth including excavation,
laying 1:4:8 cement concrete bedding, 15 cm thick burnt brick
masonry with 1:1 cement mortar plaster 25 mm thick inside and
outside 20 mm (1:3), including supplying Composites Resin Gully
Grating and frame of appropriate size and having load capcity of 20
Tonnes confirming to EN- 124:1994. Gully grating shall have
minimum 30% of water entrance area that of clear opening of the
chamber. Gully grating shall have top abrasion resistant layer of
decorative grey granite finish confirming to test performed as per IS-
15657:2006. It shall also confirm Permanent Set criteria as per EN-
124. Product should be tested in NABL accredited test lab for load
capacity and permanent set. (PWDSR.2013/14,P.N.154,I.N.93)

Spec: (As directed by Engineer in charge)


Note: In Georg Fisher Pipe System the fittings are more costly than
pipe because fro every small piece you must place the order to
company.
PAGE NO : 154
94 Providing and fixing Georg Fischer piping system of ….. outer dia
having wall thickness ….. PB Polybutylene with electw fusion (EF)
fitting, covers the growing demand for complete solutions from a
single source i.e. hot and cold water both for high and lower pressure.
All system components are stringently tested in accredited test
laboratories, certified by ISO 9001 and ISO 14001 to grantee from fit
function. These pipe system are corrosio resistance, Low thermal
conductivity, high flexibility, low fraction loss, long term performance
and mainly having a high product range considering here four system
experimental basis mostly used pipe range. Pipe are leak proof and
frost proof. Hence useful in concealed piping for toilet blocks, and
ultra violet stabilized, so it can be also use in external water supply
arrangements.(PWDSR.2013/14,P.N.155,I.N.94)

Spec: (As directed by Engineer in charge)


a) 16 mm ……. 2.2 mm
b) 20 mm …… 2.2 mm
c) 25 mm …….. 2.3 mm
d) 40 mm ……. 3.7 mm
95 Providing and fixing Georg Fischer piping system of ….. Outer dia
having wall thickness ….. Poly Ethlene for raised temperature (PE-
RT), covers the growing demand for complete solutions from a single
source i.e. hot and cold water both for high and lower pressure. All
system components are stringently tested in accredited test
laboratories, certified by ISO 9001 and ISO 14001 to guarantee from
fit function. These pipe system are corrosion resistance, Low thermal
conductivity, high flexibility, low fraction loss, long term performance
and mainly having a high product range considering here four system
experimental basis mostly used pipe range, pipe are leak proof and
frost proof. Hence useful in concealed piping for toilet bolcks, and
ultra violet stabilized, so it can be also use in external water supply
arrangement.(PWDSR.2013/14,P.N.155,I.N.95)

Spec: (As directed by Engineer in charge)


a) 16 mm ……. 2.2 mm
b) 20 mm ……. 2.2 mm
c) 25 mm ……..2.3 mm
d) 40 mm ……. 3.7 mm
PAGE NO : 155
96 Providing and fixing Georg Fischer piping system of...... Poly
Propylene random (PPR) With socket fusion fittings, covers the
growing demand for complete solutions from a single source i.e. Hot
and cold water bothe for high and lower pressure. All system
components are stingently tested in accredited test laboratories,
certified by ISO 9001 and ISO 14001 to grantee from fit function.
These pipe system are corrosion resistance, Low thermal conductivity,
high flexibility, low fraction loss, long term performance and mainly
having a high product range considering here four system
experimental basis mostly used pipe range. Pipe are leak proof and
frost proof. Hence useful in concealed piping for toilet blocks, and
ultra violet stabilized. so it can be also use in external water supply
arrangements. (PWDSR.2013/14,P.N.156,I.N.96)

Spec: (As directed by Engineer in charge)


a) 20 mm diameter
b) 25 mm diameter
c) 40 mm diameter
97 Providing and fixing Georg Fischer piping system of …… SWR pipe
Halcan silenta-silent drainage system covers the growing demand for
complete solutions from a single source i.e. hot and cold water both
for high and lower pressure. All system components are stringently
tested in accredited test laboratories, certified by ISO 9001 and ISO
14001 to grantee from fit function. These pipe system are corrosion
resistance, Low thermal conductivity, high flexibility, low fraction
loss, long term performance and mainly having a high product range
considering here four system experimental basis mostly used pipe
range. Pipe are leak proof and frost proof. Hence useful in concealed
piping for toilet blocks, and ultra violet stabilized, so it can be also use
in external water supply arrangements.
(PWDSR.2013/14,P.N.156,I.N.97)

Spec: (As directed by Engineer in charge)


a) 58 mm diameter
b) 78 mm diameter
c) 90 mm diameter
d) 110 mm diameter
e) 135 mm diameter
New Items
Note: The following all new items may be used on experimental basis for one year only.
98 Providing and fixing Stealth Facuet Angle Cock of approved jaguar o
Spec: (As directed by Engineer in charge)
99 Providing and fixing Stealth Facuet Jet Spray of approved jaguar or
Spec: (As directed by Engineer in charge)
100 Providing and erecting two legged mild steel tubular scaffolding, of wid
Spec: (As directed by Engineer in charge)
101 Providing and fixing stainless steel grade-304 kitchen trolleys made u
PAGE NO : 158
BD-W : MISCELLANEOUS
1 Providing and fixing Jute Kantan (Tarat) screen to the scaffolding of
external guniting as directed including removing the same after the
work is over etc. complete. (PWDSR.2013/14,P.N.159,I.N.1)
Spec: (As directed by Engineer in charge)
FENCING
2 Providing and erecting chain link fencing 1.6 metre height with
galvanised iron, chain link of size 50 mm x 50 mm, 8 guage thick and
fixed 75 mm above ground level on vertical mild steel angles of 40 x
40 x 6 mm size, embedded in cement concrete block of 1:4:8 mix of
size 45 x 45 x 60 cm 2.5m centre to centre with iron bar 16 mm dia. as
hold fast including welding link with angle frame at 30 cm centre to
centre including pit excavation 45 x 45 x 60 cm, nuts and bolts and
horizontal mild steel angles at top and bottom of 25 x 25 x 5 mm size
and vertical mild steel flat 35 x 5 mm and 25 x 5 mm horizontal
including cross support of 40 x 40 x 6 mm angles both sides at interval
of 25'-0" and at every corner or bend embedded in concrete blocks of
1:4:8 mix of size 45 x 45 x 60 cm including three coats of oil painting
etc. complete.(PWDSR.2013/14,P.N.135,I.N.2)

Spec: (As directed by Engineer in charge)


3 Bd/W-4 P-584 Providing and erecting 1.5 metre high wire fencing with seven rows of
barded wire supported on hard wood round bullies of 100 mm at 2.5
metres centre to centre including excavating pits for foundation, fixing
posts in cement concrete 1:4:8 blocks of size 45 x 45 x 45 cm
fastening the wire and coal tarring to wooden post in two coats etc.
complete. (PWDSR.2013/14,P.N.159,I.N.3)

PAGE NO : 159
4 Providing and fixing heavy type pipe gate having weight 43.30
kg./sqm. 50 mm dia. galvanised iron heavy type Pipe for outer frame
and 15 mm dia. heavy G.I. pipe for internal work as per approved
drawing and design with all fixtures and fittings in two leaves with
syrong hold fasts embedded in cement concrete block at top and
bottom with locking arrangements including providing Wicket Gates
as per drawing, cutting, bending and making holes, thread to pipe and
one coat of primer etc. complete.(PWDSR.2013/14,P.N.160,I.N.4)

Spec: (As directed by Engineer in charge)


RECLAMATION WORK
5 Bd/W-3 P-583 Providing and fixing 30 cm x 15 cm Marble Year Plate engraving 10
cm height figures complete. (PWDSR.2013/14,P.N.160,I.N.5)
6 Providing and fixing adjustable peg stays of approved quality 14" long
in place of broken or missing ones by welding including removing the
existing one etc.complete\.(PWDSR.2013/14,P.N.160,I.N.6)

Spec: (As directed by Engineer in charge)


7 Providing and fixing 125 mm iron handles of approved quality, make
and size in place of broken and missing ones by welding including
removing existing one etc. complete.(PWDSR.2013/14,P.N.160,I.N.7)

Spec: (As directed by Engineer in charge)


8 Providing and fixing 75/100/125/150mm iron hinges of approved
quality, make and size, fixing by welding to steel frame and shutter
and making shutters in working condition including removing existing
damaged hinges etc. complete. (PWDSR.2013/14,P.N.160,I.N.8)
Spec: (As directed by Engineer in charge)
FRENCH POLISHING TO FURNITURES
9 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. wooden benches with back of
standard size.(PWDSR.2013/14,P.N.160,I.N.9)
Spec: (As directed by Engineer in charge)
10 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Chairs teak wood of standard size.
(PWDSR.2013/14,P.N.160,I.N.10)
Spec: (As directed by Engineer in charge)
11 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Racks record of standard size.
(PWDSR.2013/14,P.N.161,I.N.11)
Spec: (As directed by Engineer in charge)
12 Repolishing with french polish with requried coats including knotting,
preparing the surface etc. complete.Racks recording big.
(PWDSR.2013/14,P.N.161,I.N.12)
Spec: (As directed by Engineer in charge)
13 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Stool wooden of standard size.
(PWDSR.2013/14,P.N.161,I.N.13)
Spec: (As directed by Engineer in charge)
14 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Table writing big size.
(PWDSR.2012/13,P.N.161,I.N.14)
Spec: (As directed by Engineer in charge)
15 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Table writing small size
(PWDSR.2013/14,P.N.161,I.N.15)
Spec: (As directed by Engineer in charge)
16 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Tray wooden.
(PWDSR.2013/14,P.N.161,I.N.16)
Spec: (As directed by Engineer in charge)
17 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Writing desk of standard size.
(PWDSR.2013/14,P.N.161,I.N.17)
Spec: (As directed by Engineer in charge)
18 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Rolling revolving chairs of
standard size.(PWDSR.2013/14,P.N.161,I.N.18)
Spec: (As directed by Engineer in charge)
19 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Dining table.
(PWDSR.2013/14,P.N.161,I.N.19)
Spec: (As directed by Engineer in charge)
20 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Tea poy of standard size.
(PWDSR.2013/14,P.N.161,I.N.20)
PAGE NO : 161
Spec: (As directed by Engineer in charge)
21 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Teak wood cupboard of standard
size. (PWDSR.2013/14,P.N.161,I.N.21)
Spec: (As directed by Engineer in charge)
22 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete.Stands with shelves.
(PWDSR.2013/14,P.N.162,I.N.22)
Spec: (As directed by Engineer in charge)
23 Repolishing with french polish with requiredcoats including knotting,
preparing the surface etc. complete. Side board.
(PWDSR.2012/13,P.N.162,I.N.23)
Spec: (As directed by Engineer in charge)
24 Repolishing with french polish with required coats including knotting,
preparing the surface etc. Complete Ward robe.
(PWDSR.2013/14,P.N.162,I.N.24)
25 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete.Sofa sets in 3 pieces.
(PWDSR.2013/14,P.N.162,I.N.25)
Spec: (As directed by Engineer in charge)
26 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Show case (big size).
(PWDSR.2013/14,P.N.162,I.N.26)
Spec: (As directed by Engineer in charge)
27 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Bench without back.
(PWDSR.2013/14,P.N.162,I.N.27)
Spec: (As directed by Engineer in charge)
28 Repolishing with french polish withrequiredcoats including knotting,
preparing the surface etc. complete. Central table.
(PWDSR.2013/14,P.N.162,I.N.28)
Spec: (As directed by Engineer in charge)
29 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Easy charis.
(PWDSR.2013/14,P.N.162,I.N.29)
Spec: (As directed by Engineer in charge)
30 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete . Teak wood cots single.
(PWDSR.2013/14P.N.162,I.N.30)
Spec: (As directed by Engineer in charge)
PAGE NO :162
31 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Teak wood cots double.
(PWDSR.2013/14,P.N.163,I.N.31)
Spec: (As directed by Engineer in charge)
32 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Dressing table.
(PWDSR.2012/13,P.N.163,I.N.32)

Spec: (As directed by Engineer in charge)


33 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Cane sofa set.
(PWDSR.2013/14,P.N.163,I.N.33)
Spec: (As directed by Engineer in charge)
34 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Garden cane chair.
(PWDSR.2013/14,P.N.163,I.N.34)
Spec: (As directed by Engineer in charge)
35 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Takht wooden.
(PWDSR.2013/14,P.N.163,I.N.35)
36 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete.Teak wood zoola.
(PWDSR.201/14,P.N.163,I.N.36)
Spec: (As directed by Engineer in charge)
37 Repolishing with french polish with required coats including knotting,
preparing the surface etc. Chest of drawer.
(PWDSR.2013/14,P.N.163,I.N.37)
Spec: (As directed by Engineer in charge)
38 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Letter Box.
(PWDSR.2013/14,P.N.163,I.N.38)
Spec: (As directed by Engineer in charge)
39 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Shoe rack.
(PWDSR.2013/14,P.N.163,I.N.39)
Spec: (As directed by Engineer in charge)
40 Repolishing with french polish with required coats including knotting,
preparing the surface etc. complete. Folding teak wood partition with
curtains. (PWDSR.2013/14,P.N.163,I.N.40)
Spec: (As directed by Engineer in charge)
PAGE NO :- 163
41 Cleaning of steel and concrete surfaces of column, beam, ceiling etc.
by compressed sand blasting including washing with pressured water
including all machineries, lead, labour, scaffolding etc. complete.
(PWDSR.2013/14,P.N.164,I.N.41)
Spec: (As directed by Engineer in charge)
42 Providing preconstructional antitermite treatment as per IS:6313 (Part-
III) by treating the bottom surface, the sides of excavation, backfill in
immediate contact with foundation, treating the top surface of plinth
filling at the rate of 5 litres of emulsion concentrate of 0.5 % of
chloropyrifos or equivalent per square metre of surface area covering
10 years' guarantee. (PWDSR.2013/14,P.N.164,I.N.42)

Spec: (As directed by Engineer in charge)


43 Providing antitermite treatment to the wooden frames of doors/
windows of the existing building as per IS: 6313 (Part-III) by drilling
6 mm dia. holes at four corners at downward angle of about 45o at the
junction of wood work and masonry and injecting 150ml of
chloropyrifos or equivalent 5% emulsion concentrate, sealing by
filling putty, covering 2 years' guarantee.
(PWDSR.2013/14,P.N.164,I.N.43)

Spec: (As directed by Engineer in charge)


44 Providing antitermite treatment to the joints of wooden beam / joists
used for the roof work of the existing building as per IS: 6313 (Part-
III) by drilling 6 mm dia. holes at four corners at downward angle of
about 45o at the junction of wood work and masonry and injecting
150ml of chloropyrifos or equivalent 5 % emulsion concentrate,
sealing by filling putty, covering 2 years' guarantee.
(PWDSR.2013/14,P.N.164,I.N.44)

Spec: (As directed by Engineer in charge)


45 Providing antitermite treatment to the sides of flooring of the existing
building as per IS: 6313 (Part-III) by punching holes 16 mm dia.
drilled at a distance of 30 cm centre to centre and injecting 50ml of
chloropyrifos or equivalent 5% emulsion concentrate per hole and
sealing by filling putty, covering 2 years' guarantee.
(PWDSR.2013/14,P.N.164,I.N.45)

Spec: (As directed by Engineer in charge)


PAGE NO:-164
46 Providing antitermite treatment around the periphery of the existing
building as per IS: 6313 (Part-III) by excavating trenches of 20 cm
width and exposing the sides of the column and plinth beams upto a
depth of 300 mm and injecting 1% of chloropyrifos or equivqlent
emulsion concentrate at the rate of 2.25 litres per metre and refilling
the trenches, covering 2 years' guarantee.
(PWDSR.2013/14,P.N.165,I.N.46)

Spec: (As directed by Engineer in charge)


47 Providing general pest control services to control the nuisance of
cockroaches, lizards, bed bugs and other insects etc. with four
operations in a year and monthly check up etc. complete.
(PWDSR.2013/14,P.N.165,I.N.47)
Spec: (As directed by Engineer in charge)
48 Providing general pest control services to big size of inspectiom
chamber to control the nuisance of cockroaches with four operations
in a year and monthly check up etc. complete.
(PWDSR.2013/14,P.N.165,I.N.48)
Spec: (As directed by Engineer in charge)
49 Providing general pest control service to small inspection chamber to
control the nuisance of cockroaches with four operations in a year and
monthly check up etc. complete. (PWDSR.2013/14,P.N.165,I.N.49)

Spec: (As directed by Engineer in charge)


50 Providing and fixing chicken wire mesh (Reference IS : 3150 - 1982 )
of 19 size of aperture at the junction of R.C.C. Members and brick
work of approved quality including fixing mesh in postion by
necessaary nailing in concrete or / B.B. masonry and or tying by
binding wire etc. complete.(PWDSR.2013/14,P.N.165,I.N.50)

Spec: (As directed by Engineer in charge)


51 Providing manual cleaning to Passages and Corridors of
Residential/Non Rsidential Govt. Building by sweeping, scrubbing,
cleaning, washing etc. Using cleaning materials/ agents, Branded
chemical and consumables etc. including all required labours etc.
complete.(PWDSR.2013/14,P.N.165,I.N.51)

Spec: (As directed by Engineer in charge)


PAGE NO : 165
52 Providing manual cleaning to Outside Permises of Residential/Non
Residental Govt. Building by sweeping, scrubbing, cleaning, washing
etc. using cleaning materials/agents, Branded chemical and
consumables etc. including all requried labours etc. complete.
(PWDSR.2013/14,P.N.166,I.N.52)

Spec: (As directed by Engineer in charge)


53 Providing manual cleaning to Common Toilet of Residential/Non
Residential Govt.Building by sweeping scrubbing, cleaning, washing
etc. using cleaning materials/agents, Branded chemical and
consumables etc. including all requried labours etc. Complete.
(PWDSR.2013/14,P.N.166,I.N.53)

Spec: (As directed by Engineer in charge)


54 Providing manual cleaning to Toilet Blocks in the officers flat of
Residential/ Govt. Building by sweeping, scrubbing, cleaning,
washing etc. using cleaning materials/agents, Branded chemical and
consumables etc. including all requried labours etc. complete.
(PWDSR.2013/14,P.N.166,I.N.54)

Spec: (As directed by Engineer in charge)


55 Provding mechanised and manual cleaning of open premises by
sweeping, scrubbing, Vaccum cleaning, pressure washing etc. With the
help of swingo 755 1st or Nilfisk CA 750, Vaccum cleaner and hard
Scrubber for Entreance, Corridor, passage area between work stations
and staircase.(PWDSR.2013/14,P.N.166,I.N.55)

Spec: (As directed by Engineer in charge)


56 Providing manual cleaning to outside area of Residential/Non
Residental Govt. Building by Johnson Balimat 45 or Nilfisle flipper
and High presure Jet including all requried labours etc.complete.
(PWDSR.2013/14,P.N.166,I.N.56)
Spec: (As directed by Engineer in charge)
57 Providing cleaning the General Toilers Blocks of Residential/Non
Residental Building manually and with the help of Johnson Divervac
Diversey 30 or Nilfisk WD-225 and Diverwash or Nilfisk N 410.
(PWDSR.2013/14,P.N.166,I.N.57)
Spec: (As directed by Engineer in charge)
PAGE NO :- 166
58 Providing cleaning the window glasses of Residential/Non Residential
Govt. Building manually and with the help of Back pack Vaccum
cleaner and Glass cleaning kit etc. complete.
(PWDSR.2013/14,P.N.167,I.N.58)
Spec: (As directed by Engineer in charge)
New Items
Note: The following all new items may be used on experimental basis for one year only.
VIDEO PHOTOGRAPHY
59 Providing and carrynig out Video shooting with Cassette for 1 Hour
Shooting of roads, bridges, other structures and programme, including
prelminary survey, still shots moving shooting, necessary board ofr
video shooting hiring of vehicle, equipment for video shooting,
transportation of all equipment, persons, required for shooting,
lighting arrangement as may be necessary, editing mixing, titling,
lettering, sounding including cost of coloured cassetee of approved
quality etc.complete.(PWDSR.2013/14,P.N.167,I.N.59)

Spec: (As directed by Engineer in charge)


60 Providing and carrying ourt video shooting of road, bridges building,
other programmes including hiring of vehicle equipment for video
shooting, tiltling, lightening, mixing, lettering, editing, including coast
of two colour cassettes of approved make and quality etc. complete.
(PWDSR.2013/14,P.N.167,I.N.60)

Spec: (As directed by Engineer in charge)


a) Within 50 Kilometers
b) Beyond 50 Kilometers
c) Work up to 6 hours per day only
61 Shooting of still photographs outdoor and indoor of construction and other works of bui
Spec: (As directed by Engineer in charge)
a) Still Photo Post Card size
b) Still Photo 4" x 6" size
c) Still Photo 5" x 7" size
d) Extra copies - Post Card size
e) Extra copies - 4" x 6'' size
f) Extra copies - 5'' x 7'' size
PAGE NO :- 167
AUTOCAD DRAWINGS
62 Printing of drawing on Autocad of ........ Size with tracing on
reproducting paper from available sources per number.
(PWDSR.2013/14,P.N.168,I.N.62)
Spec: (As directed by Engineer in charge)
a) AO (1165 x 817 mm )
b) A1 (817 x 570 mm)
c) A2 (570 x 396 mm)
d) A3 (396 x 275 mm)
e) A4 (285 x 198 mm)
63 Preparing drawing on Autocad with one proof print of ....... Size on
plain white paper with black colour print providing tracing with saving
on disk.(PWDSR.2013/14,P.N.168,I.N.63)
Spec: (As directed by Engineer in charge)
a) AO (1165 x 817 mm )
b) A1 (817 x 570 mm)
c) A2 (570 x 396 mm)
d) A3 (396 x 275 mm)
e) A4 (285 x 198 mm)
64 Editing and correction on drawing of ....... Size and giving the prints on tracing paper.(PW
Spec: (As directed by Engineer in charge)
a) AO (1165 x 817 mm )
b) A1 (817 x 570 mm)
c) A2 (570 x 396 mm)
d) A3 (396 x 275 mm)
e) A4 (285 x 198 mm)
PAGE NO :- 168
SURVEY
65 Total station survey of existing compound area showin existing plot
boundary, structure, electric poll, man hole, chamber, trees location
detail, adjoining road etc.(PWDSR.2013/14,P.N.169,I.N.65)
Spec: (As directed by Engineer in charge)
66 Spot level/contour survey at 5 mtr. X 5 mtr. W.R.T Town Hall Dattum
or temporary bench mark.(PWDSR.2013/14,P.N.169,I.N.66)

Spec: (As directed by Engineer in charge)


67 Town Hall Dattum FLY Temporary B.M.C Bench Mark.
(PWDSR.2013/14,P.N.169,I.N.67)
Spec: (As directed by Engineer in charge)
68 Scanning CTS Plan and super impose on survey drawing.
(PWDSR.2013/14,P.N.169,I.N.68)
Spec: (As directed by Engineer in charge)
69 Floor detail plan and calculate carpet area and built up area of existing
structure.(PWDSR.2013/14,P.N.169,I.N.69)
Spec: (As directed by Engineer in charge)
a) Floor detail plan showing existing structure.
b) Door and window schedule wall section/ elevation, find out carpet are
70 Global Position Survey (GPS) and find out LAT LONG of existing
compound wall corner, for aviation.(PWDSR.2013/14,P.N.169,I.N.70)

Spec: (As directed by Engineer in charge)


71 Set out proposed building location, find out open space as per
Architect Drawing or approved drawing.
(PWDSR.2013/14,P.N.169,I.N.71)
Spec: (As directed by Engineer in charge)
72 Demarkation pile foundation of site as per pile lay out.
(PWDSR.2013/14,P.N.169,I.N.72)
Spec: (As directed by Engineer in charge)
Demarkation Column Centre line, grid line on site for as per site
73 requirement of site engineer.(PWDSR.2013/14,P.N.169,I.N.73)
Spec: (As directed by Engineer in charge)
Providing and installing of condensed Aerosol fire extinguishing
system (Generator) Protection by Volume/Area-in Cu/Mtr 0.08 cum.
Consist of parameters such as Non Toxic, Non Pressurised, Non
Pyrotechnic and Green labled. Conforming to NFPA:2010 and ISO
15779 :2011 standards. Certified by UL/KIWA/BSI. Approved for
A.B. and C Class of fires. Activation through Thermal Sensor, Fire
74 Extingusihant Panesl and Self activation @ 300 Degree Celsius in one
unit only, and Life 15 Years with minor maintenance. Seismically
qualified by an Indian authority. Accepted by Mumbai Fire Brigade,
with AMC for a period of 10 years is included.
(PWDSR.2013/14,P.N.170,I.N.74)

Application Areas :
Electrical panels, CPU'S, DB'S, Air Connditioners
Spec: (As directed by Engineer in charge)
Providing and installing of condensed Aerosol fire extinguishing
system (Generator) Protection by Volume/Area-in Cu/Mtr ....... .
Consist of parameters such as Non Toxic, Non Pressurised, Non
Pyrotechnic and Green labled. Conforming to NFPA:2010 and ISO
15779 : 2011 standards. Certified by UL/KIWA/BSI. Approved for
A,B and C Class of fires. Activation through Thermal Sensor, Fire
75 Extingusihant Panel and Self activation @ 300 Degree Celsius in one
unit only. Having Stainless Steel body and Life 15 Years with minor
maintenance. Seismically qualified by an Indian authority. Accepted
by Mumbai Fire Brigade, with AMC for a period of 10 years is
included.(PWDSR.2013/14,P.N.170,I.N.75)

Spec: (As directed by Engineer in charge)


a) 5.0 cum
b) 12.0 cum
c) 57.0 cum
Application Areas :
Electrical panels, CPU'S, DB'S, Air Connditioners
Note : The price of Cable Range-680 Degree Celsius to 105 Degree
Celsius at Rs. 1275/- per Rmt. And / or price of Bulb Thermal Sensor
Range 57 Degree Celsius to 182 Degree Celsius at Rs. 8850/- per
No.will charge extra.
Providing and fixing of European make Durlax luxor 100% acrylic
ultra voilet solid surface sheet 6mm thick of all series (white,
crayon,aspeon, pebble, neon) and 9mm thick medi series for
application of table tops, counter tops, interior wall cladding making
straight cut bathroom sinks, door jams, window jams, vanity, shower
cubical, mirror frames, washroom partition, reception desk, interir
column cladding, planter, singnage, operation theatre wall cladding,
sealing, nursing counter, laboratory tops, hygiene surface, crash guard,
storage rack, providing for cantee, commercial kitchen and VIP rooms,
having specification density ASTMD-792A, flexural strength ASTM,
water absorption ASTMD-696 hardness bar coal ASTND-2583,
tensile strength ASTMD-638, having heat expansion ASTM-696,
76 Ignition test ASTM-2863, elongation at yield, Impact resistance, wear
resistant ANSIZ14.6 and having fire resistant and retardant, luster
stable resistance NEMA LD3-3.3, high temperature resistance NEMA
LD3-3.6 including boiling water resistance, stain resistance, chemicl
resistance. The luxor product series must have passed the tests
conducted by the state building testing center and the state chemical
building testing center, Work shall be guaranteed for 10 years and
guarantee shall be provided on bond paper by manufacturer.
(PWDSR.2013/14,P.N.171,I.N.76)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of
Supeintending Engineer.
Providing and fixing of European make Durlax aspiron solid surface
6mm thick of all series sheets (white, solid, sand, magna,
quantro,moon) for application of table tops, counter tops, interior wall
cladding making straight cut bathroom sinks, door jams, window
jams, vanity, shower cubical, mirror frames, washroom partition,
reception desk, interior column cladding, planter, ssignage, opertion
theatre wall cladding, sealing, nursing counter, laboratory tops,
hygiene surface, crash guard, storage rack, providing for canteen,
commercial kitchen and VIP rooms, having specification density
ASTMD-792A, barcol hardness ASTMD-2583, flexural strength AST,
water absorption ASTME-696 hardness bar coal ASTND-2583, tensile
strength ASTMD-638, tensile modulus ASTMD-638 having flexural
77 modulus, flexural density ASTM-790, ASTM-696 Ignition test
ASTM-2863M tensile strength ASTMD-638, Thermal expansion
ASTMD-696, high temperature NEMA LD3, having ball drop NEMA
LD3, water absorption ASTM D570, fire resistant and retardant. The
aspiron product series must have passed the tests conducted by the
state building testing center and the state chemical building testing
center, Work shall be guarantedd for 10 years and guarantee shall be
provided on bond paper by manufacturer.
(PWDSR.2013/14,P.N.172,I.N.77)

Spec: (As directed by Engineer in charge)


Note: The item should be executed with prior approval of
Supeintending Engineer.
Providing and applying approved epoxy resin EPI Bond of Krishna
Conchem or equivalent before polymer plaster / concrete to have the
perfect bond between old concrete and new concrete/polymer plaster
78 surface confirming to ASTM-C-882-87 using nylon brushes
scaffolding labour etc. complete.(PWDSR.2013/14,P.N.172,I.N.78)
ON
Unit Rate For 2013-14
(in Rs.) Labour
Complete

Cum. - 211.35

Cum. - 228.40

Cum. - 244.65

Cum. - 53.10

Cum. - 57.25

Cum. - 73.10

Cum - 565.25

Cum. - 141.25
Cum. - 723.40

Cum. - 1129.85

Cum. 770.00 723.40

Hour 91.00 -
Hour 102.85 -
Hour 115.75 -

Cum. 66.40 -

Cum. 631.95 -

Cum. 851.00 333.30

Cum. - 193.90
Cum. 1354.40 249.10

TION

Rmt. 1933.95 1388.25

Rmt. 2011.75 1369.00


Rmt. 2230.80 1394.05
Rmt. 2278.70 1399.55
Rmt. 2621.00 1438.80
Rmt. 2246.45 -
Rmt. 2764.80 1455.10
Rmt. 2915.40 1472.35
Rmt. 3072.85 1490.35
Rmt. 3252.85 1367.15
Rmt. 3004.55 -
Rmt. 3593.15 1549.85
Rmt. 3784.85 1571.75
Rmt. 3357.40 -
Rmt. 4325.45 1384.75
Rmt. 4141.65 -
Rmt. 4730.90 1377.90
Rmt. 4586.05 -
Rmt. 5311.55 1746.30
Rmt. 6078.30 1834.09
Rmt. 5546.70 -
Rmt. 6906.65 1928.70
Rmt. 7099.45 1860.75
Rmt. 7817.85 2045.70

Rig Hour - 722.70


Rig Hour - 963.60
Rig Hour - 1202.85
Rig Hour - 1885.95
No. 63853.50 42040.30
No. 74149.20 52335.85
No. 96482.50 74669.15
No. 117407.80 95594.45
No. 138360.50 116547.2
No. 158210.20 136396.9
No. 193612.40 171799

Rmt. 400.30 -
Rmt. 434.90 -
Rmt. 837.70 -
Rmt. 888.20 -
Rmt. 918.60 -
No. 336.60 ..

Rmt. 52.45 34.50

ONCRETE

Cum. 4930.40 801.25


Cum. 5267.50 802.75
Cum. 5635.60 802.75
Cum. 6094.40 802.75
Cum. 6365.65 802.75
Cum. 6753.05 802.75
Cum. 6587.40 802.75
Cum. 6826.45 802.75

Cum. 6689.70 -

Cum. 6491.75 802.75

Cum. 6491.75 802.75

Sqm. 97.05 34.35

Sqm. 92.70 27.50


Sqm. 1099.95 251.80

Sqm. 1623.25 414.95

Sqm. 785.35 251.80

Sqm. 1169.30 414.95

Sqm. 599.80 251.80


Sqm. 1068.80 360.55

Sqm. 1278.70 389.75

Sqm. 1536.50 469.30

T CONCRETE
cement content of 400/425/450 kg/ m3 respectively.
sign confirming conditions of IS 456/2000. It may be
cal and within limit as prescribed in the IS 456/2000 )
noted and necessary condition be mentioned in the

Cum. 6702.20 1022.45

Cum. 6849.50 1022.45

Cum. 6996.85 1022.45

Cum. 7181.00 1022.45


Cum. 7365.15 1022.45

Cum. 6702.15 1022.45


Cum. 6849.50 1022.45
Cum. 6996.85 1022.45
Cum. 7181.00 1022.45
Cum. 7365.15 1022.45
Cum. 7578.00 -

Cum. 8197.65 1619.75


Cum. 8344.95 1619.75
Cum. 8492.30 1619.75
Cum. 8676.50 1619.75
Cum. 8860.65 1619.75
Cum. 9062.55 -
Cum. 8418.50 1947.25
Cum. 8565.85 1947.25
Cum. 8713.20 1947.25
Cum. 8897.35 1947.25
Cum. 9089.45 1947.25
Cum. 9315.35 -

Cum. 9486.80 2188.10


Cum. 9634.15 2188.10
Cum. 9781.50 2188.10
Cum. 9965.70 2188.10
Cum. 10149.85 2188.10
Cum. 10387.30 -
Cum. 9165.65 2043.60
Cum. 9313.00 2043.60
Cum. 9460.30 2043.60
Cum. 9644.50 2043.60
Cum. 9828.65 2043.60
Cum. 10065.30 -

Cum. 8718.75 1860.55


Cum. 8866.05 1860.55
Cum. 9013.40 1860.55
Cum. 9197.60 1860.55
Cum. 9381.75 1860.55
Cum. 9617.30 -
Cum. 9318.65 2188.10
Cum. 9465.95 2188.10
Cum. 9613.30 2188.10
Cum. 9797.45 2188.10
Cum. 9981.65 2188.10
Cum. 9435.00 -

Cum. 11196.00 2188.10


Cum. 11345.00 2188.10
Cum. 11559.00 2188.10
Cum. 11633.00 2188.10
Cum. 11903.00 2188.10
Cum. 12113.00 -

Cum. 9626.90 2236.30


Cum. 9774.25 2236.30
Cum. 9921.60 2236.30
Cum. 10105.75 2236.30
Cum. 10289.95 2236.30
Cum. 10491.85 -

Cum. 11269.00 2814.30


Cum. 11419.00 2814.30
Cum. 11632.00 2814.30
Cum. 11706.00 2814.30
Cum. 11976.00 2814.30
Cum. 12186.00 -

Cum. 8656.00 1832.60


Cum. 8829.05 1850.95
Cum. 8976.40 1850.95
Cum. 9160.55 1850.95
Cum. 9344.70 1850.95
Cum. 9580.15 -

Cum. 10908.50 2814.39


Cum. 11055.85 2814.30
Cum. 11203.15 2814.39
Cum. 11387.35 2814.30
Cum. 11773.45 2918.75
Cum. 12541.70 -

M.T. 72028.95 7145.95

M.T. 70856.55 7145.95

M.T. 6544.70 2898.40

Sqm. 594.70 90.65


Litre 8.70 -
Litre 7.25 -
Cum. - 1514.05

Cum. - 839.65

Sqm. 497.00 ..
Sqm. 510.00 ..
Sqm. 302.15 ..
Kg. 180.00 ..

Kg. 45.00 ..

Cum. 29870.00 ..

Cum. 8652.00 ..

Sqm. 151.00 ..

RK
Cum. 6556.55 964.75

Cum. 6549.20 964.75

Cum. 6898.75 1195.10

Cum. 6726.80 1195.10

Cum. 6898.75 1195.10

Sqm. 916.05 131.30


Sqm. 677.65 57.65
Sqm. 982.20 57.65
Sqm. 1046.35 57.65
Cum. - 225.75

Per Cm. - 5.60


Depth

asis for one year only.


Cum. 5984.00 ..

Sqm. 680.80 ..
Sqm. 735.00 ..
Sqm. 1034.50 ..

Sqm. 836.00 ..
Cum. 5239.00 ..
NRY
Cum. 4209.15 1305.05

Cum. 4209.15 1305.05

Cum. 4579.75 1617.55

Cum. 5373.75 1995.15

Cum. 5325.35 2135.30

Cum. - 259.75

No. - 226.65

FING
Sqm. 360.70 45.45

Sqm. 791.10 172.10


Sqm. 188.95 40.20

Sqm. 946.70 399.75

Per Hole 520.90 86.25

Sqm. 356.70 174.65

Cum. 4147.90 1746.55

Sqm. 454.85 237.29


Sqm. 458.65 130.95

Sqm. - 40.40

Cum. - 481.70

Sqm. - 22.05

Sqm. 373.40 45.45


Sqm. 1230.85 610.65

Sqm. 238.25 123.59

Cum. - 566.75

Sqm. 569.15 151.85


Sqm. 668.00 -

Cum. 600.00 -

asis for one year only.


Sqm. 988.80 ..

Kg. 809.00 ..

Kg. 338.00 ..

sion of this item in the estimate.


Sqm. 1287.00 ..
Sqm. 250.00 ..

Sqm. 828.00 ..

Rmt. 495.00 ..

Sqm. 1332.70 ..
Sqm. 674.15 ..

Sqm. 284.00 ..
Sqm. 1043.00 ..
Sqm. 1163.75 ..

Sqm. 250.00 ..
302.00 ..
Sqm. 1617.00 ..

No. 931.00 ..
Sqm. 749.00 ..

Sqm. 249.00 ..
Sqm. 549.00 ..
Sqm. 399.00 ..
Sqm. 498.00 ..
Sqm. 599.00 ..
Sqm. 418.00 ..
Sqm. 519.00 ..
Sqm. 799.00 ..

INTS

Sqm. 1877.05 393.05


Sqm. 2500.75 520.60
Sqm. 2559.65 505.75
Sqm. 3483.85 750.80

Sqm. 2102.80 393.05


Sqm. 2435.65 520.60
Sqm. 2712.70 505.75
Sqm. 3421.85 750.80

OINTING

Sqm. 138.60 81.55


Sqm. 129.20 81.55

Sqm. 215.20 101.90


Sqm. 203.90 101.90
Sqm. 196.40 101.90
Sqm. 340.60 180.40

Sqm. 330.85 176.09

Sqm. 342.35 178.15

Sqm. 447.85 241.90

Sqm. 564.20 323.25


Sqm. 478.35 273.80

Sqm. 52.00 44.85

Sqm. 835.80 593.55

Sqm. 159.40 135.90

Sqm. 139.50 117.90

Sqm. 247.10 207.90

Sqm. 194.25 162.90

Sqm. 159.40 135.90

Sqm. - 22.65

Sqm. 94.80 36.20


Sqm. 189.60 72.15

Sqm. 28.90 16.60

Sqm. 56.95 33.25

Sqm. 76.20 37.75

basis for one year only


Sqm. 222.00 ..

NG AND DADO

Sqm. 396.25 105.40


Sqm. 404.00 105.40

Sqm. 580.75 125.40

Sqm. 586.35 125.40

Sqm. 613.50 184.50


Sqm. 639.70 184.50
Sqm. 816.60 184.50

Sqm. 2244.90 143.30

Sqm. 2297.80 178.00

Sqm. 572.60 184.50

Sqm. 587.90 184.50

Sqm. 807.15 184.50


Sqm. 345.85 115.00

Sqm. 409.75 115.00

Sqm. 332.70 115.00

Sqm. 383.55 115.00

Sqm. 476.90 184.10

Sqm. 579.70 184.10

Sqm. 575.30 218.30


Sqm. 609.85 218.30
Sqm. 1075.75 338.35

Sqm. 857.45 338.35

Sqm. 1161.75 405.00

Sqm. 956.95 405.00

Sqm. 609.20 327.45

Sqm. 585.70 327.45

Sqm. 729.50 327.45


Sqm. 633.80 327.45

Sqm. 617.00 327.45

Sqm. 657.70 405.25

Sqm. 634.20 405.25

Sqm. 679.55 405.25

Sqm. 666.50 405.25

Sqm. 529.45 171.65


Sqm. 580.50 171.65

Sqm. 632.30 209.35

Sqm. 669.90 209.35

Sqm. 794.40 133.40

Sqm. 1716.20 176.60

Sqm. 1754.10 209.10

Sqm. 786.70 178.20


Sqm. 685.10 305.10

Sqm. 562.20 251.00

Sqm. 639.20 215.30

Sqm. 718.85 215.30

Sqm. 948.05 215.30

Sqm. 2863.80 197.50

Sqm. 547.85 215.30

Sqm. 535.95 215.30


Sqm. 610.95 215.30

Sqm. 561.95 136.60

Sqm. 551.45 136.60

Sqm. 566.20 141.00

Sqm. 580.50 141.00

Sqm. 931.20 350.70

Sqm. 371.70 55.60

Sqm. 921.10 114.75


Sqm.

Sqm. 795.35 124.80


Sqm. 978.95 124.80
Sqm. 12.60 11.20

Sqm. 28.30 28.30

Sqm. 64.85 64.85

Sqm. 35.40 34.00

Sqm. 136.00 96.30

Sqm. - 36.85

Sqm. 996.90 338.35


Sqm. 1089.20 390.55

Sqm. 6040.55 -

Sqm. 849.55 -
Sqm. 950.20 -
Sqm. 1000.50 -
Sqm. 1151.55 -
Sqm. 878.35 -
Sqm. 983.80 -
Sqm. 1036.50 -

Sqm. 1185.50

Sqm. 1267.75

Sqm. 1334.05 ..
Sqm. 1095.30 186.00

mental basis for one year only.


Sqm. 1456.20 -

perintending Engineer.
Sqm. 1299.00 -
Sqm. 864.85 ..
Sqm. 807.95 ..
Sqm. 1313.45 ..

Sqm. 574.00 ..
HES
Sqm. 30.65 23.00

Sqm. 18.35 12.65

Sqm. 47.65 40.85

Sqm. 97.95 75.00

Sqm. 16.85 9.05

Sqm. 7.70 5.75

Sqm. 15.30 10.00

Sqm. 596.95 319.45

NG
Sqm. 30.15 19.95
Sqm. 26.35 12.00
Sqm. 47.65 19.95

Sqm. 27.05 12.00


Sqm. 48.85 19.95

Sqm. 27.05 12.00


Sqm. 48.85 19.95
Sqm. 51.00 21.95

Sqm. 36.65 21.95


Sqm. 45.35 29.95
Sqm. 10.25 9.55

Sqm. 14.65 7.95


Sqm. 19.10 7.95
Sqm. 17.55 7.95
Sqm. - 19.75

Sqm. 65.15 29.95

Sqm. 69.65 29.95

Sqm. 69.70 29.95

Sqm. 14.40 13.30

Sqm. 24.00 13.30

Sqm. 119.05 23.10

NG AND DISTEMPERING

Sqm. 9.60 5.85


Sqm. 18.40 9.85
Sqm. 18.85 10.80
Sqm. 35.75 17.75
Sqm. 54.95 17.75

Sqm. 14.45 13.75

ic permission from the Superintending Engineer.

Sqm. 13.20 9.50


Sqm. 52.45 36.45

Sqm. 588.00 ..

RK
Sqm. 2431.50 129.35
Sqm. 4684.05 129.35

Cum. 97842.80 4177.19


Cum. 46716.00 4181.30
Sqm. 2230.70 155.55

Cum. 84625.45 21707.40


Cum. 44232.70 21453.50
Cum. 70584.90 10033.55

Sqm. 945.10 120.30


Sqm. 388.40 120.30
Rmt. 718.40 287.95

Rmt. 347.80 74.25

Sqm. 4591.45 1834.30

Sqm. 4347.05 1743.65


Rmt. 173.15 97.55

Sqm. 2398.75 659.05

Sqm. 1163.40 321.75

Sqm. 875.20 207.55

Rmt. 522.55 104.75

Rmt. 290.70 104.75

Rmt. 673.35 156.80

Rmt. 375.90 148.55

Per Step 1793.20 333.35


Sqm. 3661.40 977.60

Sqm. - 35.40

Sqm. - 35.40

Sqm. 4491.40 977.60

EILING
Sqm. 540.85 82.45

Sqm. 558.30 82.45

Rmt. 179.00 75.35

Sqm. 576.75 59.50


Sqm. 470.20 119.00

Sqm. 453.70 59.20

Sqm. - -

Rmt. 386.15 117.25

Rmt. 3591.25 354.60

Rmt. 2804.30 273.15

No. 436.80 23.60

Sqm. 299.45 68.00

Sqm. 607.05 110.15

Sqm. 600.70 129.00


Sqm. 89.60 54.35

Sqm. 32.60 18.10

Sqm. 45.50 41.35

Sqm. - 46.75

Sqm. - 69.85

Sqm. - 24.55

Sqm. - 31.40

No. - 499.35

Quintal - 339.55

Rmt. 82.15 15.20


Rmt. 33.65 15.20
Sqm. 264.40 27.60
Sqm. 766.80 493.80

Sqm. 933.05 555.95

Sqm. 556.50 58.90

Sqm. 644.45 357.70

Sqm. 663.80 377.10


Sqm. 1378.15 65.15

Sqm. 1582.30 1086.75

Sqm. 1808.95 565.55

Sqm. 1070.05 59.20


Sqm. 2041.50 -
Sqm. 1893.55 -

ORS AND PARTITIONS

Cum. 115953.40 30602.00


Cum. 78743.95 30602.00
Cum. 201432.10 30602.00

Sqm. 4028.15 1608.75

Sqm. 3779.20 1359.85


Sqm. 5449.70 1601.15

Sqm. 6178.85 1596.60

Sqm. 5368.80 1630.30

Sqm. 5985.80 1630.30

Sqm. 4833.25 1549.65

Sqm. 5809.90 1549.65

Sqm. 4235.45 1567.35


Sqm. 4837.35 1567.35

Sqm. 3866.35 1119.50

Sqm. 3634.35 1092.40

Sqm. 4325.40 1338.45

Sqm. 4038.60 1338.45

Sqm. 3652.10 1362.75

Sqm. 3929.75 1362.75


Sqm. 5354.20 2009.45

Sqm. 3949.00 1474.90

Sqm. 3834.70 514.55

Sqm. 1969.75 358.15

Sqm. 4287.55 1333.00


Sqm. 3692.40 1333.00

Sqm. 3407.10 13344.90

Sqm. 3663.10 1322.60

Sqm. 3014.25 334.35

Sqm. 3891.55 331.10


No. 111.10 61.10

Rmt. 74.50 37.95

No. 81.95 15.25

No. 55.00 ..

No. 612.50 125.20

No. 1303.75 317.85

Sqm. 4807.80 1880.60

Sqm. 3702.00 1701.65

Sqm. 4903.90 1862.30


Sqm. 3752.30 1710.85

Sqm. 4820.40 1851.35

Sqm. 5154.05 2757.20

Sqm. 4624.00 1764.00

Sqm. 4144.90 1672.39

Sqm. 4068.10 1629.35


Sqm. 7888.70 1830.00

Sqm. 2339.55 837.80


Sqm. 2127.15 758.30
Sqm. 1830.30 594.25

Sqm. 1065.00 273.05

Sqm. 4660.30 1787.75


Sqm. 6015.95 2857.30

Sqm. 5865.95 2837.65


Sqm. 4167.65 1529.50
Sqm. 8855.65 1489.05

Sqm. 3450.90 516.25

Sqm. 3054.10 548.45


3509.10 548.45
Sqm. 3546.95 659.65
Sqm. 4152.90 659.65

Sqm. 2221.60 349.90


Sqm. 2615.05 349.90
Sqm. 2866.75 488.20
Sqm. 3373.75 488.20
Sqm. 1173.65 139.15

Sqm. 586.30 240.70

Sqm. 475.90 240.70

Sqm. 959.30 240.70

Sqm. 2678.90 367.05

Sqm. 2813.60 367.05

Sqm. 2420.30 232.60

Sqm. 2449.20 530.60


Sqm. 1296.35 345.25

Sqm. 1767.60 345.25

Sqm. 1882.25 345.25

Sqm. 3664.15 931.10

Sqm. 3074.45 930.30

Sqm. 3308.60 930.30

Sqm. 2526.25 531.85

Sqm. 13044.40 5266.30


Sqm. 13686.05 5315.50
Rmt. 955.10 91.55

Rmt. 108.90 51.75

Sqm. 270.80 52.05


Sqm. 305.90 47.40
Sqm. 374.75 47.40
Sqm. 443.65 47.40

Sqm. 237.00 47.40


Sqm. 269.70 47.40

Sqm. 555.40 128.10


Sqm. 317.40 128.10
Sqm. 887.20 467.55
Cum. 71896.00 12136.80

No. - 170.25

No. - 114.20

Smt - 43.55

Rmt. 1175.75 75.10

Rmt. 849.70 69.15


Sqm. 5594.70 1082.25

Sqm. 385.60 50.60

Smt 434.35 50.60

Sqm. 381.85 50.10

Sqm. 309.80 31.05

Sqm. 1694.35 -
Sqm. 1723.70 -

Sqm. 2359.40 149.05

Sqm. 2439.25 149.05


Sqm. 2643.95 149.05

Sqm. 5772.40 1662.10

Sqm. 5303.05 1563.95

Sqm. 4780.30 932.55


Sqm. 2342.10 613.15
Sqm. 2111.05 613.15
Sqm. 1961.15 613.15

Sqm. 22662.20 -

Sqm. 1431.10 412.50

Sqm. 1431.10 412.50


Rmt. 532.65 -
Rmt. 571.75 -

Sqm. 3261.55 -
Sqm. 3580.60 -
Sqm. 4878.20 -

Sqm. 1907.70 778.25

Sqm. 2504.60 778.25

Sqm. 5922.00 1387.00

Sqm. 720.85 116.75

Sqm. 2505.25 636.39

Sqm. 3720.75 104.80

Cum. 161145.80 9591.00

Cum. 10106.40 9591.00

ntal basis for one year only.


Sqm. 3270.00 ..

No. 27000.00 ..

Sqm. 3656.00 ..

Rmt. 440.95 ..

Sqm. 6879.40 ..

K
Sqm. 1448.15 417.25

Kg. 98.70 19.85

Sqm. 2206.65 358.85

Sqm. 2185.30 355.59

Per Step - -

M.T 80596.35 8864.95

M.T 82971.65 8754.85

M.T 77713.90 8864.95


M.T 17880.00 ..
M.T 16273.00 ..
M.T 15037.00 ..
M.T 14543.00 ..
M.T 13307.00 ..
M.T 12318.00 ..
M.T 11947.00 ..

TARY FITTINGS

Rmt. 203.85 14.40

Rmt. 205.75 15.15

Rmt. 267.45 21.25

Rmt. 291.00 22.45

Rmt. 408.35 28.05

Rmt. 561.40 29.79

Rmt. 694.10 44.45

Rmt. 956.80 45.69

Rmt. 1287.90 55.90


Rmt. 284.15 71.15

Rmt. 292.25 78.55

Rmt. 357.75 81.05

Rmt. 383.40 82.25

Rmt. 529.70 102.95

Rmt. 702.60 104.60

Rmt. 1498.90 112.29

Rmt. 232.05 71.15

Rmt. 240.45 78.55

Rmt. 263.95 81.05

Rmt. 331.80 82.25


Rmt. 373.30 102.95

Rmt. 622.90 104.60

No. 5179.70 619.15


No. 6004.10 661.65
No. 7361.15 704..15
No. 12064.00 704.15
No. 13602.35 746.65
No. 20979.60 746.65
No. 27938.70 746.70

No. 379.90 56.95

No. 289.25 56.95

No. 153.25 56.95

No. 375.45 56.10


No. 441.30 56.10
No. 531.75 62.80
No. 686.70 67.09
No. 975.60 71.15
No. 1265.90 71.15
No. 2956.05 75.35
No. 4088.00 79.55
No. 1625.85 331.39

No. 1658.25 331.39

No. 1859.25 331.39

No. 212.40 56.10

Rmt. 731.05 106.70

No. 7316.95 2273.50

No. 5759.20 1699.80

No. 5692.90 1699.80


No. 8321.95 1699.80

No. 8095.30 1699.80

No. 8480.60 1699.80

No. 8032.00 2273.50

No. 8258.65 2273.50


No. 7040.10 1303.20

No. 5595.25 1303.20

No. 10213.15 1954.80

No. 7323.45 1954.80

No. 13386.15 2606.40

No. 9561.55 3116.35

No. 16559.15 3258.00

No. 10779.75 3258.00

No. 4501.70 1274.85

No. 5351.65 1444.85

No. 6201.55 1614.85

No. 7051.45 1784.80

Rmt. 549.55 135.00


No. 3950.40 1036.90

No. 4022.90 1036.90

No. 3935.00 1036.90

No. 4702.85 1036.90

No. 5156.15 1036.90

No. 3898.25 1036.90

No. 5642.55 1346.50

No. 1560.20 300.45

Rmt. 1139.30 147.05


Rmt. 1513.70 278.69

Rmt. 2378.35 279.55

Rmt. 1209.70 279.35

Rmt. 1358.90 276.60

Rmt. 801.95 107.70


Rmt. 411.20 144.90

Rmt. 515.80 144.90

Rmt. 448.95 123.15

Rmt. 360.40 123.15

Rmt. 318.15 155.90

Rmt. 515.15 124.25

Rmt. 409.65 111.80


Rmt. 571.90 124.25

Rmt. 438.60 119.39

No. 350.85 -

No. 2051.10 314.05

Rmt. 273.85 88.75

Rmt. 314.35 89.65

Rmt. 616.50 89.65

No. 8637.85 1241.65


No. 12367.10 1873.45

No. 9842.85 1457.15

No. 26986.65 4520.10

Rmt. 1037.20 236.50

No. 655.15 295.20

No. 1104.90 85.09

No. 838.55 85.09

No. 328.60 85.09

No. 260.65 85.09

No. 220.95 85.09


No. 249.75 -

Sqm. 848.80 -

No. 450.45 -

No. 428.05 -

No. 394.15 -

No. 222.25 -

No. 1784.80 85.09

No. 130.30 51.09


No. 220.95 51.09

No. 1671.50 85.09


No. 1195.55 119.09
100 Litre - 15.30

Sqm. 1776.05 -

Rmt. - 218.15

No. 172.75 100.09

No. - -

No. 975.70 85.09

No. 15779.60 ..

No. 16898.75 -
No. 3835.80 -

No. 17801.30 -

Litre 7.00 -

Rmt. 212.50 -
Rmt. 261.25 -

Rmt. - -
Rmt. - -
Rmt. - -
No. - 46.40
No. - 119.05

Rmt. 666.20 93.59


Rmt. 902.40 93.59
Rmt. 1257.50 93.59

Rmt. 553.15 41.75


Rmt. 1062.75 26.85
No. 531.25 148.75

No. 266.60 56.95

No. 273.85 56.10


No. 515.90 56.95

No. 374.05 83.75

No. 305.95 85.09

No. 252.15 42.50

No. 263.45 42.50

No. 4592.35 1359.85

No. 2933.35 687.39


No. 6068.65 663.00

Ltr. 0.11 0.11

No. 4580.95 673.20

No. 5697.40 673.20

No. 5892.85 673.20

No. 3241.15 673.20

Rmt. 958.00 -
Rmt. 143.00
Rmt. 179.00
Rmt. 241.00
Rmt. 353.00
Rmt. 421.00

Rmt. 363.80 -

Rmt. 128.00
Rmt. 155.00
Rmt. 186.00
Rmt. 234.00
Rmt. 288.00
Rmt. 345.00
No. 18865.75 -

Kg. 120.00 -

No. .. -

No. .. ..
Rmt. 447.00 -
Rmt. 584.00 -
Rmt. 752.00 -
Rmt. 1526.00 -

Rmt. 153.00 -
Rmt. 181.00 -
Rmt. 217.00 -
Rmt. 393.00 -
Rmt. 140.00 -
Rmt. 175.00 -
Rmt. 315.00 -

Rmt. 788.00 -
Rmt. 849.00 -
Rmt. 1044.00 -
Rmt. 1229.00 -
Rmt. 1594.00 -

ntal basis for one year only.


No. 1685.30 ..

No. 2121.45 ..

Sqm. 189.55 ..

Kg. 384.75 ..
OUS
Sqm. 9.25 3.30

Rmt. 1237.85 256.80

Rmt. 659.45 129.19

Sqm. 4440.75 632.30

No. 139.90 -

No. 23.75 -
No. 13.20 -

No. 27.70 -

No. 140.05 -

No. 69.90 -

No. 92.90 -

No. 158.00 -

No. 55.55 -

No. 195.25 -

No. 175.95 -

No. 26.45 -

No. 159.50 -
No. 146.05 -

No. 168.20 -

No. 56.80 -

No. 263.90 -

No. 121.35 -

No. 40.10 -

No. 230.50 -

No. 156.65 -

No. 213.20 -

No. 107.25 -

No. 112.65 -
No. 105.90 -

No. 200.60 -

No. 320.45 -

No. 158.90 -

No. 195.25 -

No. 51.70 -

No. 156.65 -

No. 143.55 -

No. 158.95 -

No. 27.75 -

No. 51.70 -
No. 112.65 -

Sqm. - 71.95

Sqm. 87.15 -

Per No. 66.80 -

Per Joint 42.40 -

Per Hole 16.00 -


Rmt. 62.80 -

Sqm. 13.00 -

No. 119.80 -

No. 59.90 -

Sqm. 346.50 ..

100 Sqm. 8.20

100 Sqm. 2.84 ..


One toilet 25.65 ..

100 Sqm. 35.55 ..

100 Sqm. 9.55

100 Sqm. 3.02 ..

One toilet 166.70 ..

Sft. 0.44 ..

ntal basis for one year only.

Hour 2500.00 ..
Sqm.

Day 4500.00 ..
Day 5800.00 ..
6 Hrs. 3300.00 ..
tion and other works of building, bridges, roads etc. In district and outside district at any distance.(PWDSR.2013/14,P.N.167

3 copies 70.00 ..
3 copies 95.00 ..
3 copies 200.00 ..
1 copy 30.00 ..
1 copy 50.00 ..
1 copy 60.00 ..

No. 650.00 ..
No. 525.00 ..
No. 470.00 ..
No. 460.00 ..
No. 260.00 ..
Sqm.

No. 2100.00 ..
No. 1600.00 ..
No. 1300.00 ..
No. 1100.00 ..
No. 700.00 ..
e prints on tracing paper.(PWDSR.2013/14,P.N.168,I.N.64)

No. 750.00 ..
No. 650.00 ..
No. 600.00 ..
No. 450.00 ..
No. 350.00 ..
Sqm. 6.00 -

Sqm. 4.00 -

Lum Sum 6000.00 ..

Lum Sum 5000.00 -

.. .. ..

Sqm. 27.00 ..
Sqm. 43.00 ..
Lum Sum 25000.00 -

Day 7000.00 -

Day 7000.00 -

Day 7000.00 ..

Cum. 5750.25 ..
Cum. 72611.00 ..
Cum. 121171.00 ..
Cum. 245370.00 ..

Sqm. 11500.00

..
Sqm. 8925.00 ..

Sqm. ..
WDSR.2013/14,P.N.167,I.N.61)
Sr. No.
1

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

1
2
3
4
5
6
7

1
2
3
4

6
7

1
2
3
4
1
2
3
4
5
6

1
2
3
4
5

1
2
3
4

1
2
3
4
5
6

1
2
3
4
5
6
7

1
2
3
4
5
6
7
8
9
10

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153

154

155
156
157
158
159
160
161
162
163
164
165
166
167

1
2
3
4

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95

96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19

20

21

22

23
24
25
26
27
28
29
30
31
32
33
Sr. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56

Sr. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33

Sr. No.
1

2
a)

b)
c)
d)
e)
f)
g)
3

8
9

10

11

Sr. No.

2
3
4
5
6
7
8

9
10

11
12
13
14
15

16

17
18
19
20

21
22

23
24

25
26
27
28
29
30

31

32

33

34

35
36
37
38
39
40

41
42
43
44
45
46
47

48
49
50
51
52

53
54
55
56
57
58
59
60
61
62
63

64

65
66
67

68

69

70

71

72

73

74

75

76

77
78

79
80

81
82

83
84
85
86
87
88
89

90
91

92

93
94
95
96
97

98
99
100
101
102
103

104

105
106
107
108

109

110
111
Important Note:

Sr. No.
1
2
3
4
5
6
7
8

Bd/B: PILE
FOUNDATION
Sr. No.
1
Bd/E : PLAIN CEMENT
CONCRETE
Sr. No.

1
2
3
4
5
6
7
Sr. No.

1
2
3
4
5
6
7
Bd/G BRICK
MASONARY
Sr. No.
1

2
3
4
5
B/d H : STONE
MASONARY
Sr. No.
1
2
3
Sr. No.
4
5
Bd/J: WATER PROOFING
TREATMENT

Sr. No.

1
2
3
4
5
Bd/L : PLASTERING &
POINTING
Sr. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Bd

Sr. No.

1
2
3
4
5

8
9
10
11
12
13
14
15
16

17

18
19
20

21

22
23

24
25
26

27

28
29

30
31
32
33

34
35
36
37
38
39
40
Bd/V: WATER SUPPLY & SANITARY

Sr. No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Sr. No.
19
20
21
22
GENERAL MATERIAL FOR BUILDING DSR 2013-14
Note :- All materials are supply on site
Material
2

Brick Bat
Brick Second Class
Cement Grey O.P.C
Grit
Mild Steel bars
Mild Steel Plate
Murum (Hard) at site including loading and unloading
Murum (Soft) at site including loading and unloading
Quarry spouls
Rubble for masonry
Rubble for Metal/Soling etc.
send double screened
Hand broken Stone Metal (No.2) 25mm
Hand broken Stone Metal (No.3) 40 to 50 mm
Hand broken Stone Metal 60 x 80 mm
Structural Steel
T.M.T. Steel Bar
Tor Steel / Mild Steel
Bd/A :
3'' size metal trap (60 to 80 mm)
Blasting Powder
Fuse
Metal for filling the voids (12 to 20)
Rubble Stone (Blasted)
Soft Murum
Spoules (On Quary)
Bd/B :
Bentonite
Metal 12 mm (crushed)
Metal 20 mm (Crushed)
MS Plate (2x1mx1x0.25@Rs.45000/MT) Cost of 392.40Kg=45000x0.3924=17658.00/30

Rs Joist (300x200x6.70@ 10cm apar 27 x 7 mtrs x 40.90kg=7730.10kg i.e.7.73 MT x


45000/30
Sand screened
Wooden Slipper (5mx0.20x0.10 each 5x5x0.10=2.50 Cum. Load test upto 100MT) 2.5 x
45000/20
Bd/E :
Jungel wood plank
Trap Metal 12 mm
Trap Metal 20 mm
Trap Metal 40 mm
Bd/F :
Galvanised iron Binding Wire 1.63 mm
Jungle wood Ballies
Mild Steel upto 10 mm dia
RCC Jali 50 mm thick
Teak Wood Ballies
Ready Mix Concrete M-30 Grade
Bd/G:
5'' cut nail of 6 mm dia
M.S. Bar
Siporex Block (100 x 240 x 600)
Siporex Block (150 x 240 x 600)
Siporex Block (200 x 240 x 600)
Bd/H:
Corner/Quions 30x20x30cm
Khandkies
Rubble TR @ Quarry (Masonry)
T.R. Header (17x22x45)
Bd/J :
Bituman 85/25 Grade
Fire Wood
Waterproofing Compound
Readymix Polymer Modified Morter-SUNMIX
Bipolar Concrete Penetrating Corrosion Inhibiting Admixture- POLYALK CP 293
Sacrificial Anod-SUNANODDE (for protection to steel bar in RCC repari work)
Bd/K:
Alluminium Hold Fast
Alluminium Strips
Bitumen Joints Filler
G.I. Screws (Couch) 50 mm
Lead Pipe /Plate
Premolded filler 25 mm thick
T.W. Purlins/Planks for Girders, Joists etc.
Bd/L:
Fine Aggregates (Grit)
High Grade Mineral Pigment
Neeru
Plaster of Paris
Synthetic Fiber 6/12 mm -35
Green Build Product - Built Fast Plus
Green Build Product - Green Grout
Green Build Product - Eco Render Plus
Green Build Product- Green Repair
Green Build Product - Green Seal
Bd/M:
Bees Wax
Black Kadappa (Machine cut 25 mm thick)
Broken China Tiles
Cement O.P.C
Cement Tiles Colour
Cement Tiles Plain
Ceramic Tiles 300 x 200 mm (decorative)
Ceramic Tiles 300 x 200 mm (Plain)
Ceramic Tiles 300 x 300 mm (decorative)
Ceramic Tiles 300 x 300 mm (Plain)
Ceramic Tiles 450 x 450 mm (decorative)
Ceramic Tiles 450 x 450 mm (Plain)
Vitrified tiles 400 mm x 400 mm (decorative) 8 mm to 10 mm thick
Vitrified tiles 450 mm x 300 mm (decorative) 8 mm to 10 mm thick
Vitrified tiles 600 mm x 300 mm (decorative) 8 mm to 10 mm thick
Vitrified tiles 900 mm x 900 mm (decorative) 8 mm to 10 mm thick
Chequred Cement tiles (Plain)
Chequred Cement tiles (Colour)
Colour Cement (Pigment)
Floor Washing Powder
Glazed Tiles (20 x 10 cm) White
Galazed Tiles 150 x 150 mm Colour
Galazed Tiles 200 x 100 mm Colour
Granite Slab colour 60 x 45 cm 20 mm th
Green Marble Slab
Kadappa Stone 40 mm thick
Kadappa Stone 25 to 30 mm thick (one side polish)
Kotha Stone 25 to 30 mm thick
Marble Chips
Marble Mosaic Tiles 25 x 25 cm (White)
Marble Mosaic Tiles 25 x 25 cm (Grey)
Marble Powder
Mosaic Tiles Colour
P.V.C. Flooring Roll 2 mm thick
Pigment for Tiles
Polished Shabad Stone (Machine Cut 25 mm )
Polished Shabad ( 25 to 30 mm)
Polished Tandoor (25 to 30mm)
Polished Tandoor (40mm)
Polished Tandur Stone
Precast concrete paver block 40 mm th.
Precast concrete paver block 60 mm th.
Rough Shahabad (25 to 30 mm)
Rough Shahabad (40 to 50 mm)
Rough Shahabad (50 to 60 mm)
Tarazoo Tiles
White Cement
White Cement
White Glazed Tiles 150 x 150
white Marble slab 25 mm
Whit Marble Slab
Bd/N :
Coal Tar
French Polish
Hardner
Kerosene
Linseed Oil
Melamine Polish
Polish paper, Putty, Cloth
Terpentine
Varnish
Bd/O:
Acrylic Latex Paint Pretreatment Coat
Acrylci Latex Paint Exterior Primer Coat
Acrylic Latex Paint Exterior
Alluminium Paint
Anticorrosive Primer Coat
Cement Paint
Flat Oil Paint
Plaster of Paris
Putty
Ready Mix Wall Primer
Ready Mix Wood Primer
Red Oxide Paint
Seal Cement Primer
Sealing Coat
Synthetic Enamal Paint
Bd/P:
Colour Powder
Colouring Stuf
Lime
Oil Bound Distemper
Plastic Emulsion Paint
Powder Distemper
Sand Paper, Whiting
Fire Retardant Primer (Fireguard)
Fire Retardant Paint (Fireguard)
Bd/Q:
Alluminium Rod 25 mm dia
Block Board 25 mm thick
Seasoned Teak Wood
Caps 100 mm
Decorative Plywood Veneer 4 mm
G.I. Screws 50 mm
Girder (Jungle Wood)
Handle Iron oxidised 125 mm
Iron oxidised 75 mm Hinges
Jungle Wood
Laminate Board 20 mm
Lamination Sheet
Nails
Nut bolt 16 mm dia
PVC Hand rail
Screw and Nails
Structural Steel
Teak Wood General (Purlin/Rafter)
Tower Bolt 100 mm
Tower Bolt 150 mm
TW Girder
TW Partical Board 12 mm
TW Plank 25 mm thick
TW Plank 50 mm thick
Veneer Board 20 mm (one side veneer)
Bd/R:
AC Sheet (Plain) 4 mm
AC Sheet (Plain) 6 mm
AC Sheet Ridge
Battens 50 x 25 mm
Bitumen Washer
Brass Screws
Connection Clips
Dungry Cloth 42'' wide (1.05m)
G.C.I Sheet Corrugated 22 gauge (basic rate = Rs. 240/- per Sqm. (size 1x1m)
G.I Screws (Couch) 50 mm
GI J-Hooks & Bolts with washer
GI J-Hooks 6 mm dia
GI Screw / Bolt
GI Sheet plain 22 G. (1.2 x 1.8 M)
GI Washers
Glass Tile (Manglore)
Half perfrated board 12 mm
Holders
Intermidiate Channel
M.T. Ridge / Hip Tiles
Manglore Tiles ''AA''
Perimeter Channel 80 x 8 mm
Pitch
Plaster of Paris Board 45 x 45 cm
Rawal Plug
Ridge Cap (Plain G.I)
Screws 1 1/2''
Screws 1/2''
TW Battens (25 x 12 mm)
TW Battens (50 x 25 mm)
TW Battens / Bedding Pat
Vertical Support
Wire
Bd/T:
Aldrop 300 mm Brass Oxidised
Aldrop 300 mm Iron Oxidised
Alluminium
Alluminium Handle
Alluminium Jali
Alluminium La+ch with 2 keys
Alluminium Powder
Alluminium Powder Coating
Alluminium Screw
Alluminium Section
Alluminium Sheet 23 BWG
Alluminium Sliding door bolt
Alluminium Stay
Alluminium Strip 20 x 3 mm
Alluminium Tower Bolt
Alluminium Tower Bolt 75 mm
Ball Bearing
Battens T.W. 70 x 45 mm
Bearing rollers
Black Hinges
Brass Ornamental Handle 125 mm
Brass Oxidised Hinges
Brass Oxidised hooks & eyes 225 mm
Brass Peep Window
Burm Teak Wood
Butt Hinges brass oxidised 100 mm
Butt Hinges brass oxidised 125 mm
Butt Hinges iron oxidised 100 mm
Butt Hinges iron oxidised 125 mm
Cement Bonded Particle Board 6 mm thick (IS 3809/1976)
Cement Bonded Particle Board 8 mm thick (IS 3809/1976)
Cement Bonded Particle Board 10 mm thick (IS 3809/1976)
Cement Bonded Particle Board 12 mm thick (IS 3809/1976)
Cement Bonded Particle Board 16 mm thick (IS 3809/1976)
Cement Bonded Particle Board 20 mm thick (IS 3809/1976)
Cement Mortar
Chain and Staple
Clips
Collapsible gate complete with accessories
Commercial Partical board
Commercial Plywood 19 mm thick with 5 % wastage
Commercial Plywood 4 mm thick
Commercial plywood 6 mm thick with %% wastage
Double acting hinges
DWUF 405 -40 mm x 48 mm
DWUF 412-38 mm x 32 mm
Efficient make lock
F.R.P Door shutter 30 mm thick
F.R.P. Door shutter 35 mm thick
Fevicol
Formica Laminate Sheet
Glass 3 mm thick (plain)
Glass 4 mm thick (plain)
Glass 5 mm thick (plain)
Glass Bajri 6 mm
Glass 5.5 mm (plain)
Glass Acrylic 3 mm
Glass plain 6 mm thick
Glass Rubbed
Glass plain 6 mm
Glass Acrylic Opaque Sheet 3 mm
Glass Acrylic Opaqure Sheet 5 mm
Glass Acrylic Opaqure Sheet 6 mm
Glass Wire Acrylic 5 mm
Glass Wire Acrylic 6 mm
Godrej Night Latch
Handle Brass 75 mm
Handle brass oxidised 125 mm
Hinges 75 mm
Hinges Brass 75 mm
Hinges brass oxidised 125 mm
Hinges iron oxidised 225 mm
Hooks & Eyes 100 mm Iron Oxidised
Hooks & Eyes 200 mm Iron Oxidised
Hot dip zink coating
Housing Box to rolling shutter
Hydraulic Door Closer
Iron Hold Fast 300 x 40 x 5 mm
Iron Holdfast
Iron Oxide 100 mm hinges
Iron Screw
Laminate Board 20 mm th
Latch
Lock
Marine Ply Wood 4 mm thick
Marine Ply Wood 6 mm thick
Marine Ply Wood 12 mm thick (IS 710/1996)
Marine Ply Wood 16 mm thick (IS 710/1996)
Marine Ply Wood 19 mm thick (IS 710/1996)
M.S. Flat
Magnet catch
Mech. Gear box to rolling shutter
Mild Steel Plats & Flats
Mortise Lock
Nuts and Bolts
Partical Board 12 mm thick (both side veneer)
Partical Board 12 mm thick (one side veneer)
Plain A.C Sheet 4 mm thick
Plain G.I Sheet 22 B.W.G.
Plastic Cover Block
Ply wood 12 mm thick (Commercial)
Ply wood 9 mm thick (Commercial)
PVC Gasket Lining
Rolling Shutter
Rubber Lining
Screw 25 mm
Screws Brass
Sheet Glass (7.5 Kg./ Sqm.)
Sliding door bolt (tadi) brass oxidised 250 mm
Sliding door bolt tadi 250 mm
Solid Core Commercial Ply door
Solid Core Teak Veneer finished door
ST-22 22 x 18 mm
ST-33 14 x 33 mm
Steel
Steel Tank
T.W. Battens for bedding
T.W. Parical board Commercial
T.W. Particle board 12 mm thick
T.W Particle board both side veneer (Interior Grade)
T.W Particle board one side veneer (Interior Grade)
T.W. Plank
T.W. Sash Bar (3rd size)
Teak Wood
Dismantled Teak Wood
Teak Wood Lipping
Tower bolt 100 mm Brass Oxidised
Tower bolt 100 mm Iron Oxidised
Tower bolt 150 mm Brass Oxidised
Tower bolt 150 mm Iron Oxidised
Tower bolt 200 mm Brass Oxidised
Tower bolt 200 mm Iron Oxidised
Tower bolt 250 mm Brass Oxidised
Tower bolt 250 mm Iron Oxidised
Tower bolt 300 mm Brass Oxidised
Tower bolt 300 mm Iron Oxidised
TW Plank 20 mm thick
TW Runner (6'' x 3'')
UPVC Frame for fixture and fastening
UPVC Frame with filler
UPVC Frame with multi panel shutter
UPVC Frame with multi panel shutter 20 mm th.
UPVC Frame with multi panel shutter 25 mm th.
UPVC Frame with multi panel shutter for fixture & Fastening
Veneer 4 mm thick (Natural)
Vision Pannel
Welded Mesh 25 x 25 x 2.54 mm
Welded Mesh 50 x 50 x 2.54 mm
Welded Mesh 50 x 25 x 2.54 mm
Welded Mesh 75 x 25 x 2.54 mm
XPM 20 x 2.54 mm thick
XPM 25 x 2.54 mm thick
Flambloc GS 101 (Char Forming Penetrating Fire Retardant For synthetic Fabrics)

Flambloc 200 (Char and Intumescent Foam Forming, Penetrating Fire Retardant For
Wood and Wood Product)
Flambloc GS 500
Flambloc GS 501 (Curing Agent For Flamebloc GS 500 and Flameblco GS 502)
Flambloc GS 700 (Char Forming Fire Retardant Liquid For Open Cell Foam)
6 mm Bison Plain Board 8' x 4'
8 mm Bison Plain Board 8' x 4'
10 mm Bison Plain Board 8' x 4'
12 mm Bison Plain Board 8' x 4'
16 mm Bison Plain Board 8' x 4'
18 mm Bison Plain Board 8' x 4'
20 mm Bison Plain Board 8' x 4'
25 mm Bison Plain Board 8' x 4'
30 mm Bison Plain Board 8' x 4'
40 mm Bison Plain Board 8' x 4'
Bd/U:
C.I Spirl Stair two meter redius with railing
Cutng and bending slopping reveting as per design
M.S. Flats
M.S. Plates
Bd/V:
12'' half round GSW pipe 2' length
A.C Bend 100 mm dia
A.C Bend 150 mm dia
A.C Bend 75/80 mm dia
A.C Coller 100 mm dia
A.C Coller 75/80 mm dia
A.C Cowl/Vent 100 mm dia
A.C Cowl/Vent 75/80 mm dia
A.C Ofset 63. 5 mm dia
A.C. Pipe 100 mm dia
A.C. Pipe 63.5 mm dia
A.C. Pipe 75/80 mm dia
A.C. Plain Bend 63.5 mm dia
A.C. Rain water pipe 150 mm dia
A.C Shoe 100 mm dia
A.C. Shoe 150 mm dia
A.C Slotted Cowl Dome 3'' (75 mm dia)
A.C. Slotted Cowl Dome 4'' (100 mm dia)
A.C. Slotte Vent 63.5 mm
A.C.'Y' Junction 100 mm dia
A.C.'Y' Junction 63.5 mm dia
A.C.'Y' Junction 75 mm dia
Add Lumpsum for Fitng
Add Lumpsum for Loading Arrangement
Add Lumpsum for Cement/Sand/ W.P. Compound
Add Lumpsum for Nails & wire
Add Lumpsum for painting
Additional for Hold fast fixing
ASTM Rigid PVC 110 mm pipe
ASTM Rigid PVC 20 mm pipe
ASTM Rigid PVC 25 mm pipe
ASTM Rigid PVC 32 mm pipe
ASTM Rigid PVC 50 mm pipe
ASTM Rigid PVC 63 mm pipe
ASTM Rigid PVC 90 mm pipe
Back Backlit seat for European W.C.
Ball Cock (15 mm dia and PVC flot)
Ball Cock (20 mm dia and PVC flot)
Ball Cock (25 mm dia and PVC flot)
Ball Cock (40 mm dia and PVC flot)
Ball Cock (50 mm dia and PVC flot)
Bib Stop Tap brass heavy 12 mm
Bib Stop Tap brass medium 12 mm
Bib Stop Tap Cast Iron Heavy 12 mm
Bracket
Brass Nozzle Piller Tap 12 mm
C.I. 'Y' Junction 100 mm dia
C.I. 'Y' Junction 150 mm dia
C.I. 'Y' Junction 75/80 mm dia
C.I Bend 100 mm
C.I Bend 150 mm
C.I Bend 225 mm
C.I Bend/Plug (18 G) 75 / 100 mm dia
C.I Brackets
C.I. Circular Manholel Cover
C.I. Coller 100 mm dia
C.I. Coller 150 mm dia
C.I. Coller 75 mm dia
C.I. Cover 45 x 30 cm with frame
C.I. Cover with frame (Gully trap)
C.I Cowl/Vent 100 mm dia
C.I Cowl/Vent 150 mm dia
C.I Cowl/Vent 75/80 mm dia
C.I Grating 100 mm dia
C.I Grating 225 mm dia
C.I. Manhole Cover (27 Kg.)
C.I. Manhole Cover (32 Kg.)
C.I Nahani Trap 100 mm dia
C.I Pipe 100 mm dia
C.I Pipe 150 mm dia
C.I Pipe 75/80 mm dia
C.I. Shoe 225 mm dia
C.I. Shoe 75 to 100 mm dia (18G)
C.I Steps for Manhole
C.I Trap Grating 15 x 10 cm
Cement
Cement
Centrifugal 'Y' Junction 100 mm
Centrifugal 'Y' Junction 150 mm
Centrifugal 'Y' Junction 75 mm
Centrifugal C.I. Pipe 100 mm
Centrifugal C.I. Pipe 150 mm
Centrifugal C.I. Pipe 75 mm
Centrifugal Coller 100 mm
Centrifugal Coller 150 mm
Centrifugal Cowl/Vent 100 mm
Centrifugal Cowl/Vent 150 mm
Centrifugal Cowl/Vent 75 mm
Chaina wear flushing tank with Accessories
Chromium plated alluminium towel rail (16 mm dia)
Chromium plated alluminium towel rod
Clamp
Colour Glazed sink 60 x 45 x 20 cm
Colour Glazed sink 45 x 30 x 20 cm
Supplying Composite Resin Manhole cover and frame of ........ Confirming to En- 124:
1994. Product shall have top abrasion resistan layer of decorative gray granite finish
confirming to test performed as per IS- 15658:2006. It shall also confirm Permanent Set
criterion as per EN-124. Product should be tested in NABL accredited test lab for load
capacity and permanente setc.

a) 300 x 300 mm size and having load capacity of 20 Tonnes


b) 450 x 450 mm size and having load capacity of 20 Tonnes
c) 450 x 600 mm size and having load capacity of 20 Tonnes
d) 450 x 900 mm size and having load capacity of 20 Tonnes
e) 600 x 900 mm size and having load capacity of 20 Tonnes
f) dia 600 mm size and having load capacity of 20 Tonnes
g) 450 x 900 mm size and having load capacity of 10 Tonnes
h) 600 x 900 mm size and having load capacity of 10 Tonnes
i) 450 x 900 mm size and having load capacity of 20 Tonnes
j) 600 x 900 mm size and having load capacity of 20 Tonnes
k) dia 600 mm size and having load capacity of 20 Tonnes
Supplying Composite Resin Gully Grating and frame of ....... Confirming to EN- 124 :
1994, Gully grating Shall have minimum 30 % of water entrance area that of clear
opening of the chamber. Gully grating shall have top abrasion resistant layer of
decorative grey granite finish confirming to test performed as per IS- 15658:2006. It shall
also confirm Permanent Set criteria as per EN-124. Product should be tested in NABL
accredited test lab for laod capacity and permanent set.
a) 450 x 450 mm size and having load capacity of 10 Tonnes
b) 450 x 450 mm size and having load capacity of 20 Tonnes
c) 500 x 600 mm size and having load capacity of 10 Tonnes
d) 450 x 900 mm size and having load capacity of 20 Tonnes
Fitng holding clamp
Fixing in CC BK. Clamp, Battan
Flush Tank 10 Ltr with Accessories
Foot Rest Chequered 25 x 10
G.I. Pipe 100 mm dia heavy type
G.I. Pipe 15 mm dia Heavy
G.I. Pipe 15 mm dia medium type
G.I. Pipe 20 mm dia heavy type
G.I. Pipe 20 mm dia medium type
G.I. Pipe 25 mm dia heavy type
G.I. Pipe 25 mm dia medium type
G.I. Pipe 32 mm dia heavy type
G.I. Pipe 32 mm dia Medium
G.I. Pipe 40 mm dia heavy type
G.I. Pipe 40 mm dia medium type
G.I. Pipe 50 mm dia heavy type
G.I. Pipe 50 mm dia Medium Type
G.I. Pipe 65 mm dia heaby type
G.I. Pipe 80 mm dia heavy type
G.I. PI. Rain pipe (18G) 225 mm dia
G.I. Screw 100
G.I. Screw 75 mm
GI Coupling 100 mm
GI Coupling 125 mm
GI Coupling 150 mm
GI Coupling 200 mm
GI Coupling 50 mm
GI Coupling 75 mm
GI Elbow 100 mm
GI Elbow 125 mm
GI Elbow 150 mm
GI Elbow 200 mm
GI Elbow 50 mm
GI Elbow 75 mm
GI Nipple 100 mm
GI Nipple 125 mm
GI Nipple 150 mm
GI Nipple 200 mm
GI Nipple 50 mm
GI Nipple 75 mm
GI Tees 100 mm
GI Tees 125 mm
GI Tees 150 mm
GI Tees 200 mm
GI Tees 50 mm
GI Tees 75 mm
GI Union 100 mm
GI Union 125 mm
GI Union 150 mm
GI Union 200 mm
GI Union 50mm
GSW sewer trap 15 cm x 10 cm
Gun Metal Stop Cock 20 mm
Gun Metal Stop Cock 25 mm
HDPE flushing Tank With acessories
Hemp Rope
Hemp Rope Centrifugal
Hold fast
Holder, batten,clamp,screw
Kitchen Trolley (Stainless Steel : Grade-306)
Lead pipe 32 mm dia
Lipped type urinal
Mirror 40 x 45
Mohogani Seat With Lid
Nut & Bolts
P Trap & Lead pipe 40 mm dia
Pedastal for Wash Basin Colour Glazed
PVC ''YY'' Junction 110 mm
PVC ''YY'' Junction 75 mm
PVC ''Y'' Junction
PVC 110 MM
PVC 75 MM
PVC Angle Cock with flang 15 mm
PVC Bend
PVC Bib Cock 15 mm dia (Polymer)
PVC Bib Cock 15 mm dia Long Body with flang
PVC Bottle Trap 32 mm (Polymer)
PVC Collers 75 mm
PVC Connector 110 mm
PVC Piller Cock 15 mm (Polymer)
PVC Pipe 110 MM
PVC Pipe 75 mm dia
PVC Shoe
PVC Slotted Coul 75 mm
PVC Socket and Coupling 110 mm
PVC Socket and Coupling 75 mm
PVC Stop Cock 15 mm dia (Polymer Male Thread)
PVC Trap grating
PVC Urinal Cock 15 mm dia
PVC Urinal Spreader 15 mm dia
PVC Vent 75 mm
Precast RCC Cover for Inspection Chamber 90 x 45 cm 2'' thick
Precast RCC Cover for Inspection Chamber 90 x 45 cm 4'' thick
Precast RCC Cover for Inspection Chamber 60 x 45 cm 2'' thick
Precast RCC Cover for Inspection Chamber 60 x 45 cm 4'' thick
Precast RCC Cover for gully trap (1' x 1' x 2'' thick)
Salt glazed S.W gully trap
Shower Rose Chromium Plated Brass 10 c
Socket for 12/15 mm tap
Socket for 20/25 mm tap
Socket for 32 mm tap
Socket for 40 mm tap
Socket for 50 mm tap
Socket for 65 mm tap
Socket for 80 mm tap
Spun Yarn
Stainer 100 mm
Stainer 15 mm
Stainer 20 mm
Stainer 25 mm
Stainer 40 mm
Stainer 50 mm
Stainer 80 mm
Steel Sink 60 x 45 cm
Stone ware pipe 100 mm dia
Stone ware pipe 150 mm dia
Stone ware pipe 225 mm dia
Strainer 15 mm
Shphonic Trap with 10 Ltr Low Level Cistern
Wash Basin Colour Glazed 55 x 40 cm
Wash Basin Colour Glazed 63 x 45 cm
Wash Basin White Glazed 45x30x18 cm
Wash Basin White Glazed 55 x 40 cm
Wash Basin White Glazed 63x45 cm
Water Meter 100 mm (Non R Volve)
Water Meter 15 mm (Non R Volve)
Water Meter 20 mm (Non R Volve)
Water Meter 25 mm (Non R Volve)
Water Meter 40 mm (Non R Volve)
Water Meter 50 mm (Non R Volve)
Water Meter 80 mm (Non R Volve)
Water Meter Box with lock 15m
WC Pan Colour glazed 23'' (Orisa)
WC Pan white glazed 23'' (Orisa)
WC Pan White Glazed 580 mm European
WC Pan White Glazed 580 mm Indian
Wheel Stop Tap Gun Metal 15 mm
Wheel Stop Tap Gun Metal 20 mm
Wheel Stop Tap Gun Metal 25 mm
Wheel Stop Tap Gun Metal 32 mm
Wheel Stop Tap Gun Metal 40 mm
Wheel Stop Tap Gun Metal 50 mm
Wheel Stop Tap Gun Metal 65 mm
Wheel Stop Tap Gun Metal 80 mm
White Glaze Pedestal for wash basin
White Glaze sink 60x45x20 cm
White glazed full stall urinal
White glazed half stall urinal
White Glazed sink 45x30x20 cm
Bd/W :
Aldring 30 % E.C (Emulsion Concentrate) or equivalent
Barbed Wire 12 gauge
Bullies 100 mm
Chain Link Fencing 8 Gauge
Chlordane 20 % E.C (Emulsion Concentrate) or equivalent
DDVP 100 % E.C. Or equivalent
I.R.C Fabrics 150 x 150 mm 10 gauge
I.R.C Fabrics 75 x 75 mm 10 gauge
M.S. Angles and flats
M.S. Plate including 5 % wastage
Malathion 50 % E.C. Or equivalent
Pine Oil
Polyalk E.P.
Polyalk fixo-prime
Quartz Sand
Rustiside / Rustolin
Solvent
Bamboo Matng
Bamboo Male 1'' to 1 1/2'' dia at centre, average 10' to 12' long (20 Nos. In one Cori)

Bamboo Male 1'' to 1 1/2'' dia at centre, average 13' to 20' long (20 Nos. In one Cori)

Bamboo female 1'' to 1 1/2'' dia at centre, average 10' to 12' long (20 Nos. In one Cori)

Bamboo female 1'' to 1 1/2'' dia at centre, average 13' to 20' long (20 Nos. In one Cori)

Bamboo Toker
Coir thick
Coir thin
Goa Broom
Bambu Basket
Acid for toilet
Bleaching
Hand Gloves
Mask
Gum Boot
Jacket for Sweeper with Logo
LABOUR RATES
Labour
Applicator
Bar bener (Skilled)
Foreman (Bar bender) (Skilled)
Bhistee (Mazdoor (Male) Heavy Unskilled)
Blacksmith with his tools & bellow (Skilled)
Blacksmith without his tools & bellow (Semi-Skilled)
Blending tradesman
Breaker Semi (Skilled)
Carpenter 1st Class (Skilled)
Carpenter 2nd Class (Semi Skilled)
Carpenter 3rd Class (Semi skilled)
Chiseler (Semi Skilled)
Driver (Semi-skilled)
Electrician
Fireman (Semi-skilled)
Fitter 1st Class with his tools (Skilled)
Fitter 2nd Class with his tools (Semi-skilled)
Fitter Assistant or boring fitter (Semi-skilled)
Foreman (Semi Skilled)(Carpenter 2nd Class)
Galzier with tools (Semi-skilled)
Gunman (Guniting work) (Unskilled)
Hole driller (Semi Skilled)
Making holes
Mail (Semi-skilled)
Mason 1st Class (Skilled)
Mason 2nd Class (Semi-Skilled)
Mason 3rd Class (Semi-Skilled)
Mason for Glazed Ceramic Tiling (Skilled)
Mazdoor (Female) Light Unskilled
Mazdoor (Male) Heavy Unskilled
Mazdoor (Male) Light Unskilled
Mazdoor Heavy Male (Operator) Semi Skilled
Mechanic for Mixer & Vibrator (Semi skilled)
Mixer Operator (Semi-Skilled)
Mukadam (Semi-Skilled)
Nozalman (Guniting work)(Semi-skilled)
Painter 1st Class (Skilled)
Painter 2nd Class (Semi-skilled)
Plumber with Zoola (Skilled)
Plumber with tools (2nd Class) (Semi- skilled)
Plumber with tools (Skilled)
Polishman (1st class for furniture work) (Skilled)
Polishman 2nd class (Semi- skilled)
Pump Operator (Semi Skilled)
Room boy (Unskilled)
Stone Cutter & Dresser with tools (Semi-skilled)
Sweeper dry (Unskilled)
Sweeper wet (Unskilled)
Tar Handler (Semi-skilled)
Tile turner (Semi-skilled)
Tinman (Semi-Skilled)
Vibrator Operator (Semi-skilled)
Watchman (Semi-skilled)
Welder 1st Class (Skilled)
Welder 2nd Class (Semi skilled)
Welding Point
MACHINERY HIRE CHARGES
MACHINERY
Bentonite Pump
Cement Grout Pump/Gun
Chain & Pully
Compressor
Concrete Mixture 10/7 Cft
Cutter Machine
Drilling Machine
Electricity /Fuel for 10 to 19 HP pump
Electricity /Fuel for pump upto 10 HP
Grinder
Grinding Machine
Injection Grouting Machine
Jet Water Pump
Paddle Mixer /Stirrer
Pile Boaring Machine
Pile Boaring Machine
Pile Boaring Machine
Pile Boaring Machine
Pile Boaring Machine
Pile Boaring Machine
Pipe Cuter
Pully Hire Charges
Pump 1 HP (Tulu)
Pump 2 HP (Dewatering engine)
Pump 3 HP
Pump 5 to 9 HP
Pump 10 to 19 HP
Pumping Charges for RMC
Riveting, Welding
Stirrer / Compressor
Tile Polishing Machine
Vibrator (Diesel) as per Mech. DSR
Welding Machine
Annexure - A,B,C
Annexure 'A'
Construction Material Tsting and its frequency
Material
CEMENT
1) Consistecy
2) Initial & Final Stng time

3) Fineness
4) Specific Gravity
5) Soundness
6) Compressive Strength
METAL
1) Sieve Analysis (Gradation)
(Concrete work)
2) Sieve Analysis Red Book specification
3) Sieve Analysis
Granular Sub Base (N.H. Work) MOST
Water Absorption
Impact (Concrete WBM /BT)
Crushing
Abrasion
Flakiness & Elongation Index
Plasticity Index for blindage used for WBM
SAND
1) Water Absorption & Specific Gravity
2) Fineness Modulus
3) Silt Content
4) Bulkage
BRICKS
1) Water Absorption

2) Comp Strength
3) Effloresce
Flooring Tiles
1) Flexural Strength

2) Water Absorption
3) Abrasion
Glazed Tiles
1) Water Absorption
Concrete Mix Design
Compressive strength C.C.Cubes for Qty

Qty. Upto 5 m3
6-15 m3
16-30 m3
31-50 m3
Quantity above 51 m3
MURUM/ SOIL for earth work
1) Optimum Dry Density
2) C.B.R.
3) Liquid & Plastic Limit/ Platicity Index
4) Filed Density 100% P.D.
5) Filed Moisture Content
WOOD
1) Moisture Content
2) Density
WATER
1) P.H. Value for water and Sand
2) Chloride & Sulphate content
Steel Sink 60 x 45 cm
1) Wt per meter
2) Ultimate Tensile Stress

3) Yield stress
4) Elogation
Annexure 'B'
Schedule of Testing charges for construction material used for government
Works for the Year 2013-14
Effective from 8/07/2013 and valid Upto 30/06/2014
Name of Test
BASIC TEST OF CEMENT.
Standard Consistacy Fineness, 1 Test 2800.00 Specific Gravity, Setng Time (Initial &
Final), Compressive Strenght, Soundness
BASIC TEST OF AGGREGATE.
Water Absorption, Specific Gravity. Impact Value Crushing Value.
Sieve Analysis
Abrasion Value.
Flakiness Index /Elongation Index.
Stripping Value.
Soundness
Bulk Density.
MIX DESIGN.
GSB Mix Design.
Wet Mix Macadam Mix Design.
FINE AGGREGATES.
Fineness Modulus (Sieve Analysis), Silt & Clay Content
Chloride & Sulphate Content.
Moisture Content.
Bulkage of Sand.
Silt Factor.
BRICKS
Water Absorption (Set of 5 Bricks), Cmpressive Strength (Set of 5 Bricks), Efflorescence
(Set of 5 Bricks).
FLOORING TILES (MOSSAIC / CEMENT)
Flexural test (Set of 6 Tiles), Water absorption (Set of 6 Tiles). Resistance to wear (Set of
6 Tiles).
GLAZED TILES
Water Abspr[topm (Set of 6 Tiles), Modulus of Rupture (Set of 6 Tiles)
Determination of Impact Resistance.
Determination of Chemical Resistance.
CERAMIC TILES/ VITRIFIED TILES
Water Absorption, Moduls of Rapture (Set of 6 Tiles)
Determination of Chemical Resistance.
MANGLORE TILES
Water Absorption (Set of 6 Tiles), Flexurral test (Set of 6 Tiles)
Permeability.
CONCRETE
Compressive Strength OF C.C. Cube (Set of 3 cubes).
Concrete Mix Design (With all Tests on basic materials)*
Flexural strength of Beam.
Permiability Test.
Concrete mix design by Accelerated curing method. (Boiling water method)
Taking of core samples in concrete pavement. (Excluding Dead Journey Charges)

Dead Journey Charges.


CONCRETE PAVING BLOCKS
Compressive Strength, Water Absorption (Set of 8 Blocks), Flexural Test (Set of 8 Blcoks).
Resistance to wear.(Set of 8 Blocks)
MORTOR
Compressive Strength. (Set of 3 Cubes)
STONE / RUBBLE
Crushing Value / Compressive Strength Water Absorption & Specific Gravity.
SOIL / MURUM
Sieve Analysis
Field Moisture Content.
Liquid limit & platic Limit.
Compaction Test (Proctor Density).
C.B.R. Test (Lab) Excluding compaction test.
C.B.R. Test (Field Determination Test) Excluding Transportation. As per IS 2720 Part XXXI

Dead Journey Charges, inspection Vehical


Dead Journey Charges, Truck/Tipper
Field Density by Sand replacement method.
Sulphate & Chloride Contents.
Mechanical Analysis.
Plate Load Bearing Test. (Excluding Transportation)
Free Swell Test for Soil.
BITUMEN
Penetration, Softening Point, Flash & Fire Point, Specific Gravity
Viscosity.
Ducility / Elastic Recovery
Extraction Test.
Sieve Analysis of Bituminous mix (2 samples of extraction for one sieve analysis
excluding extraction)
Marshall Stability & Flow measurement. (Set of 3 moulds)
Prepation of Marshall Mould.
Job Mix Design with all Tests on basic material for DBM/SDBC/AC
B.M. Job Mix Design (Preparation of Marshall Mould & Density).
Mastic Hardness No.
Thin film oven test & test on residue of modified bitumen.
Sepration test for modified bitumen.
Determination of Fines by Hydrometer.
Matter soluble in Trichloroethylene.
Density of Bituminous Mix Mould. (Set of 3 moulds)
Taking of core samples in bituminous flexible pavement. (Excluding dead Journey
Charges)
Dead Journey Charges.
BITUMINOUS EMULSION
% Residue Test
Particle charge Test
Sieve Test
HOLLOW BLOCKS / SOLID BLOCKS
Density Tets. (Set of 3 Blocks) Compressive Strength. (Set of 8 Blocks) Water Absorption
Test. (Set of 3 Blocks)
WATER
PH Value, Sulphate & Chloride Content.
WOOD
Density, Moisture Content.
FLUSH DOOR
Knife Test, Adhesion Test, End Immersion Test.
PLYWOOD
Determination of Resistance to dry heat, Determination of Moisture Content,
Determination of Density, Thickness of Plywood,

Test for Glue Adhesion


PARTICAL BOARD
Determination of Moisture Content, Determination of Density
ALUMINIUM SECTION
Thickness, Mass Per Running meter
Test on Powder Coating
POLYMER MATERIAL
PH Value, Solid Content
A.C PIPES
Water Absorption
Bursting Strength
A.C. SHEETS
Water Absorption,
Load Bearing
G.I. PIPES
Weight per running meter, Diameter of pipe & wall thickness of pipe,
Weight of Zinc coating per sq.m.
P.V.C PIPES (NONPLASTISIZED)
Weight per running meter, Diameter of pipe & wall thickness of pipe,
STEEL ANTI CORROSIVE TEST
Resistance to applied Voltage. ( 1 Hr. Test) (Set of 2 Bars)
Resistance to applied Voltage. (30 Days Test) ( Set of 2 Bars)
Thickness of Coating, (Set of 2 Bars)
Chemical Rsistance Test. ( Set of 8 Bars)
Hardness of Coating Test.
Salt Spray Test (4 Cycles) ( Set of 2 Bars)
STEEL BAR TESTING
Upto 16 mm (Set of 3 Bars)
Above 16 mm (Set of 3 Bars) (Tensile strength, % Elongation, Yield Strees, Weight-per
Meter, Bend/ Rebend Test, Proof Stress)
Nitrol Solution Test. (Set of 3 Bars)
PAINT / THERMO-PLATIC PAINT
Glass bead contents & grading analysis.
Reflectance & yellowness index
Flowability (Percentage residue).
Softening Point. (Ring & ball method).
Drying Time.
COAL TAR EPOXY PAINT
Drying Time.
Dry Film Thickness.
Flexibility.
Gel Time.
Pot Life.
Volume of Solid.
ROAD SIGN BOARD
Retro Reflective Test.
ROUGHNESS INDEX / ROAD UN-EVENNESS TEST
Road Surface Single Lane. (3.70 to 5.50 m)
Road Surface 1.5 Lane to Two Lane. (5.50 to 7.00 m)
Each Additional Lane.
Dead Journey Charges.
OVERLAY DESIGN
Benkelaman Beam Test (Excluding Dead Journey Charges)
NON - DESSTRUCTIVE TEST
Rebound Hammer Test.
Ultrasonic Pulse Velocity
The above rates are applicable for all Division and Subdivision under P.W.D and Z.P. In
Maharashtra and for other Government / Private Organization the rates shall be twice as
mentioned in DSR.

Annexure - C
Chart for Stage-I Estimate
Rate of Stage-I Estimate
Multi Storied Buildings upto G+1 floor Add : 0.5 % for every additional floor
R.C.C Compound Wall height 2 mtr. Above ground level
Furniture @ 20 % of Civil Cost.
Interior including partitions, wall cladding, ceiling etc. @ 20 % of Civil Cost.
Plot Development and Land Scaping @ 10 % of Civil Cost.
BMC Charges 6 % + 3% for water supply and
BMC Charges for IOD approval 2 %
Electrical Charges @ 11 % of Civil Cost
CONSUMPTION OF MATERIAL

Item
M-30 RCC cast in situ bored piles

Item

Plain cement concrete 1:5:10


Plain cement concrete 1:4:8
Plain cement concrete 1:3:6
Plain cement concrete 1:2:4
M- 20 grade PCC
M-25 grade PCC
M-30 grade PCC
Item

M- 20 grade RCC
M- 25 grade RCC
M- 30 grade RCC
M- 35 grade RCC
M- 40 grade RCC
P & F RCC Jali 50 mm. Thick CM 1:3
P & L 50 mm. Thick cement mortar 1:8

Item
Second class brick work in CM 1:6 in foundation and plinth of inner wall /external wall

Second class brick work in CM 1:6 in superstructure


Second class brick work in CM 1:8 in superstructure
Second class brick work in CM 1:6 as backing in composite masonry
Second class half brick masonry in CM 1:4 with 6mm diameter M.S. Bars.

Item
UCR masonry in CM 1:6 in foundation and plinth of inner wall / external walls.
UCR masonry in CM 1:6 in basement
UCR masonry in CM 1:6 in Super Structure
Item
CR masonry 2 nd sort in CM 1:6 in plinth
CR masonry 2nd sort in CM 1:6 in Super-structure
Item

20mm thick integral finishing in CM 1:3


W.P. To terrace 112 mm. Thick
W.P. Of BB coba to W.C. & Bath
20 mm. Thick water proof plaster in 1:3 for dado
25 mm thick water proof bedding in C.M. 1:3

Item
6 mm Plaster in CM 1:4
6 mm Plaster in CM 1:3
12 mm plaster in single coat m CM 1.5
12 mm plaster in single coat m CM 1.4
12 mm plaster in single coat m CM 1.3
20 mm cement plaster jn CM 1:4 in two coal
20 mm cement plaster in CM 1:5 in single coat
20 mm cement plaster in CM 1:4 in single coat
25 mm thick plaster in CM 1:4 in two coat
Sand faced plaster in CM 1:4 in two coats
Rough cast plaster in two coats in CM 1:4
Exterior stone crete facing in CM 1:3
Flush grooved pointing CM 1:3 to brick masonry
Flush gorooved Pointing m CM 1:3 to masonry stone
Truck pointing in CM 1:3 to masonry stone / Brick Masonry
Wwathered pointing in CM 1:3 to masonry stone / Brick Masonry
Vee pointing in CM 1:3 to stone masonry / Brick Masonry
Bd/M: PAVING AND FLOORI

Item

Rough shahabad flooring 25 to 30 mm thick bed of C.M 1:6


Rough shahabad flooring 40 to 50 mm thick bed of C.M 1:6
Rough shahabad flooring 50 to 60 mm thick bed of C.M 1:6
Rough shahabad flooring 25 to 30 mm thick bed of C.M 1:6
Polished shahabad /tandur/kotah stone 30mm thick on bed of 1 6 CM flooring 25 to

Polished shahabad /tandur/kotah stone 30mm thick on bed of 1 :4 with kadappa border
flooring 25 to
Polished Shahabad /Tandur kotah stone flooring 25 lo 30mm thick for dado on 1:4
cmement mortar plaster
IPS flooring in 40 thick proportion M-20
IPS flooring in 50 thick proportion M-20
IPS flooring in 40 thick proportion M-15
IPS flooring in 50mm thick proportion M-15
Plain cement die 25x25 cm flooring bed on C.M 1:4
Plain cement tiles for dado and skirting C.M 1:4
Plain coloured cement tiles for flooring bed on C.M. 1:4
Plain coloured cement tiles for dado on Plaster of CM 1:4
White glazed tiles 148.50x 148.50/200x100mm /Ceramic tile -300 x 300 mm /300x
200mm /450x450mm/ Decorative ceramic tile -300x300mm/300x200mm for flooring on
CM 1.4

White glazed tiles 148.50x 148.50/200x100mm /Ceramic tile -300 x 300 mm /300x
200mm /450x450mm/ Decorative ceramic tile -300x300mm/300x200mm for flooring on
CM 1.4

Coloured glazed Tiles 148.50x 148.50/200x100mm for flooring on bed of 1 4 CM


Coloured glazed Tiles 148.50x 148.50/200x100mm for dado on bed of 1 4 CM
Gray/ white cement based marble mosaic tiles for flooring on 1.4 cement plaster

Gray / White cement base marble mosaic tiles for dado and skirting on 1 4 cement
plaster
P & L Machine cut marble slab 60 x 45 cm flooring on 1:4 cement mortar bed
P & L Machine cut marble slab 60 x 45mm dado and skirting on 1:4 cement mortar bed

P & L in situ cement marble mosaic 10mm thick for flooring


Providng and laying in situ cement mosaic dado and skirting 6mm Thick
P & flooring of Tukda mosaic /china mosaic (broken Mosaic tile pieces) on bed of 1 4
cement mortar
P S L polished shahabad / tandur / kotah stone slab for treds & risers on bed of 1:4 CM

Polished shahabad stone 40 lo 50 mm for treads and risers in CM 1:4


Plain cement tiles / plain coloured cement tiles of 20mm thick treads and risers on bed
of 1:4 CM
Marble slabs 20 mm thick lor treads and risers 20 to 25 mm thick
Rough shahabad stone 40 to 50 mm for treads and risers on bed of 1:4 CM
White marble slabs dado and shirting
Precast polished plain chequered tiles / coloured cement tiles and treads and plain
cement tiles or risers
Polished chequered marble mosaic tiles 20 x 32 cm size for flooring / treads
Marble /Kadappa /Tandur stone partition for urinals
Mirror polish marble slab 20 mm thick for boxing
25 mm thick polished kadappa for kitchen platfrom
Concrete paver block -40mm thick / 60 mm thick
Rectified & Vetrified mirror polished 600 x600 mm for flooring
Rectified & Vetrified mirror polished 600 x600 mm for dado
Bd/V: WATER SUPPLY & SANITARY

Item
Indian type W.C pan
Orissa type WC pan
European type W.C pan
Renewing Indian type W.C pan Full stall type urinal
Lipped flat back type urinal
Half round white glazed
Half round salt glazed stone ware pipe in brick masonry
White glazed earthenware wash hand basin
White glazed earthenware sink
Nahani trap 8 cm or 10 cm dia
Cast iron rain water pipe 75/1 DO/1 50 mm dia
Asbestos cement rain water pipe 100 /15Qmm dia
Cast iron soil /waste water /vent pipe of BO/1 00 /1 50mm dia
Asbestos cement soil /waste water/ vent pipe of 75 / 1 DO / 1 50mm dia
Salt glazed stoneware pipe 100 mm dia
Slat glazed stoneware pipe 150 mm dia
Slat glazed stoneware pipe 225 mm dia
P.V.C pipe 110 mm /75mm
Item
Brick Masonry inspection chamber 60 x 45 cm, 60 cm depth.
Brick Masonry inspection chamber 90 x 45 cm, 60 cm depth.
Intercepting Chamber 90 x 45 cm with brick masonry and plaster
Circular Man Hole 45 cm dia at top and 90 cm at Bottom and 1.80 to 2.70 mtr. Depth
wiht plaster
Unit Per Rate for 2013-14 (in Rs.)
3

Cum. 550.00
No. 7.00
Bag 325.00
Cum. 1100.00
M.T. 54000.00
M.T. 54000.00
Cum. 400.00
Cum. 400.00
Cum. 550.00
Cum. 650.00
Cum. 600.00
Cum. 3500.00
Cum. 850.00
Cum. 820.00
Cum. 800.00
M.T. 62500.00
M.T. 54000.00
M.T. 52000.00

Cum. 850.00
Kg. 50.00
Rmt. 15.50
Cum. 900.00
Cum. 360.00
Cum. 420.00
Cum. 530.00

M.T. 1600.00
Cum. 1210.00
Cum. 1200.00
Kg. 624.00

M.T. 12175.00

Cum. 3500.00
Cum. 5900.00

Cum. 21200.00
Cum. 1200.00
Cum. 1200.00
Cum. 1200.00
Kg. 90.00
Rmt. 185.00
M.T. 54000.00
Sqm. 400.00
Rmt. 70.00
Cum. 5640.00

Kg. 25.00
Kg. 54.00
No. 67.00
No. 95.00
No. 110.00

No. 26.50
No. 14.00
Cum. 642.00
No. 26.00

Kg. 43.00
Kg. 4.00
Kg. 27.00
Kg. 30.00
50 Kg. Bag 90.00
No. 800.00

No. 23.50
Kg. 190.00
Kg. 21.50
Gross 77.50
Kg. 65.00
Sqm. 768.00
Cum. 47250.00

Cum. 1500.00
Kg. 40.00
Kg. 3.00
Bag 240.00
125 grm 60.00
Kg. 440.00
Kg. 530.00
Kg. 545.00
Kg. 670.00
Kg. 900.00

Kg. 35.00
Sqm. 325.00
Bag 6.00
Bag 290.00
Sqm. 140.00
Sqm. 120.00
Sqm. 327.00
Sqm. 298.00
Sqm. 341.00
Sqm. 315.00
Sqm. 429.00
Sqm. 383.00
Sqm. 510.00
Sqm. 595.00
Sqm. 637.50
Sqm. 765.00
Sqm. 200.00
Sqm. 230.00
Kg. 95.00
Kg. 45.00
Sqm. 475.00
Sqm. 400.00
Sqm. 475.00
Sqm. 2500.00
Sqm. 1300.00
Sqm. 460.00
Sqm. 460.00
Sqm. 460.00
Kg. 18.00
Sqm. 280.00
Sqm. 280.00
Kg. 10.00
Sqm. 210.00
Sheet 310.00
Kg. 130.00
Sqm. 350.00
Sqm. 310.00
Sqm. 310.00
Sqm. 380.00
Sqm. 330.00
Sqm. 625.00
Sqm. 900.00
Sqm. 250.00
Sqm. 270.00
Sqm. 300.00
Sqm. 560.00
Kg. 40.00
Bag 1300.00
Sqm. 315.00
Sqm. 1800.00
Sqm. 1700.00
Kg. 20.00
Ltr. 64.00
Ltr. 960.00
Ltr. 25.00
Ltr. 52.00
Ltr. 680.00
No. 22.00
Ltr. 37.00
Ltr. 55.00

Ltr. 322.00
Ltr. 112.00
Ltr. 292.00
Ltr. 135.00
Ltr. 145.00
Kg. 40.00
Ltr. 150.00
Kg. 20.00
Kg. 20.00
Ltr. 90.00
Ltr. 90.00
Ltr. 90.00
Ltr. 52.00
Ltr. 132.00
Ltr. 150.00

Kg. 5.70
Kg. 7.00
Kg. 5.50
Kg. 70.00
Kg. 215.00
Kg. 35.00
No. 15.00
Ltr. 450.00
Ltr. 506.00

Kg. 247.00
Sqm. 970.00
Cum. 61840.00
No. 22.00
Sqm. 485.00
Gross 126.00
Cum. 33038.00
No. 20.00
No. 10.00
Cum. 13500.00
Sqm. 730.00
Sqm. 355.00
Kg. 100.00
No. 40.00
Rmt. 245.00
Kg. 125.00
Kg. 62.50
Cum. 49000.00
No. 15.00
No. 20.00
Cum. 74500.00
Sqm. 665.00
Cum. 77000.00
Cum. 80000.00
Sqm. 1130.00

Sqm. 190.00
Sqm. 280.00
Pair 200.00
Cum. 40000.00
No. 0.25
Gross 220.00
No. 6.00
Kg. 12.00
M.T. 48000.00
Gross 83.00
No. 8.00
No. 11.00
No. 2.00
Sqm. 400.00
No. 1.50
No. 350.00
No. 125.00
Rmt. 55.00
Rmt. 55.00
No. 25.00
No. 13.00
Kg. 145.00
Kg. 15.00
No. 60.00
No. 0.60
M.T. 48000.00
No. 0.60
No. 0.50
Cum. 36000.00
Cum. 36000.00
Cum. 36000.00
Rmt. 35.00
Kg. 95.00
No. 480.00
No. 145.00
Kg. 210.00
No. 18.00
Sqm. 1200.00
No. 490.00
Kg. 220.00
Kg. 212.00
Doz. 15.00
Kg. 215.00
Kg. 290.00
No. 48.00
No. 34.00
Rmt. 25.00
No. 29.00
Cum. 48.00
No. 298.00
Cum. 43300.00
No. 65.00
No. 19.00
No. 315.00
No. 70.00
No. 60.00
No. 45.00
Cum. 123587.00
No. 156.00
No. 220.00
No. 34.00
No. 90.00
Sqm. 815.00
Sqm. 905.00
Sqm. 920.00
Sqm. 1300.00
Sqm. 1340.00
Sqm. 1900.00
No. 32.00
No. 56.00
Doz. 20.00
Sqm. 1700.00
Sqm. 352.00
Sqm. 1400.00
Sqm. 512.00
Sqm. 632.00
No. 69.00
Rmt. 262.00
Rmt. 215.00
No. 142.00
Sqm. 2100.00
Sqm. 2900.00
Kg. 192.00
Sqm. 940.00
Sqm. 240.00
Sqm. 322.00
Sqm. 400.00
Sqm. 500.00
Sqm. 428.00
Sqm. 512.00
Sqm. 490.00
Sqm. 158.00
Sqm. 490.00
Sqm. 510.00
Sqm. 645.00
Sqm. 770.00
Sqm. 700.00
Sqm. 810.00
No. 870.00
No. 75.00
No. 92.00
No. 40.00
No. 110.00
No. 112.00
No. 90.00
No. 21.00
No. 32.00
Kg. 42.00
Sqm. 1270.00
No. 430.00
No. 30.00
No. 25.00
No. 18.00
No. 3.00
Sqm. 975.00
No. 920.00
No. 230.00
Sqm. 693.00
Sqm. 924.00
Sqm. 990.00
Sqm. 1400.00
Sqm. 1450.00
Kg. 55.00
No. 32.00
No. 455.00
Kg. 55.00
No. 420.00
No. 35.00
Sqm. 565.00
Sqm. 558.00
Sqm. 122.00
Sqm. 312.00
No. 3.00
Sqm. 800.00
Sqm. 635.00
Rmt. 13.00
Sqm. 1600.00
Rmt. 12.00
Doz. 16.00
No. 3.00
Sqm. 290.00
No. 65.00
No. 22.00
Sqm. 1000.00
Sqm. 2150.00
Rmt. 45.00
Rmt. 53.00
Kg. 62.50
No. 60.00
Rmt. 22.00
Sqm. 500.00
Sqm. 665.00
Sqm. 1255.00
Sqm. 1120.00
Cum. 64900.00
Cum. 64800.00
Cum. 60500.00
Cum. 49000.00
Cum. 61000.00
No. 52.00
No. 28.00
No. 73.00
No. 39.00
No. 106.00
No. 52.00
No. 131.00
No. 69.00
No. 159.00
No. 78.00
Sqm. 1700.00
Cum. 62000.00
No. 72.00
Rmt. 232.00
Sqm. 1750.00
Sqm. 1800.00
Sqm. 2000.00
Sqm. 135.00
Sqm. 700.00
No. 60.00
Sqm. 271.00
Sqm. 330.00
Sqm. 212.00
Sqm. 178.00
Sqm. 181.00
Sqm. 153.00
Kg. 1350.00

Kg. 1550.00

Kg. 1900.00
Kg. 1900.00
Kg. 1200.00
Sqm. 221.00
Sqm. 293.35
Sqm. 371.03
Sqm. 453.02
Sqm. 598.31
Sqm. 670.96
Sqm. 746.72
Sqm. 933.80
Sqm. 1117.75
Sqm. 1491.89

Steps 900.00
Kg. 16.00
Kg. 54.00
M.T. 54000.00

Rft. 175.00
No. 85.00
No. 145.00
No. 85.00
No. 115.00
No. 75.00
No. 150.00
No. 120.00
No. 100.00
Rmt. 180.00
Rmt. 100.00
Rmt. 120.00
No. 55.00
Rmt. 240.00
No. 90.00
No. 180.00
No. 150.00
No. 70.00
No. 90.00
No. 120.00
No. 100.00
No. 100.00
L.S 30.00
L.S 25.00
L.S 30.00
L.S 26.00
L.S 25.00
No. 15.00
Rmt. 713.00
Rmt. 60.00
Rmt. 94.00
Rmt. 130.00
Rmt. 218.00
Rmt. 350.00
Rmt. 495.00
No. 340.00
No. 90.00
No. 125.00
No. 185.00
No. 635.00
No. 870.00
No. 250.00
No. 170.00
No. 50.00
No. 80.00
No. 180.00
No. 540.00
No. 1715.00
No. 390.00
No. 290.00
No. 750.00
No. 1250.00
No. 350.00
Pair 70.00
Kg. 70.00
No. 210.00
No. 470.00
No. 546.00
No. 700.00
No. 394.00
No. 250.00
No. 720.00
No. 220.00
No. 48.00
No. 120.00
No. 1890.00
No. 2240.00
No. 595.00
Rmt. 765.00
Rmt. 1386.00
Rmt. 654.00
No. 1300.00
No. 305.00
No. 385.00
No. 25.00
M.T. 6500.00
Kg. 6.50
No. 780.00
No. 1700.00
No. 510.00
Rmt. 880.00
Rmt. 1560.00
Rmt. 700.00
No. 335.00
No. 675.00
No. 360.00
No. 735.00
No. 275.00
No. 3500.00
No. 220.00
No. 350.00
No. 25.00
No. 1850.00
No. 720.00

No. 1422.00
No. 3350.25
No. 4045.50
No. 5562.00
No. 7394.65
No. 5371.90
No. 9606.35
No. 11300.65
No. 10820.25
No. 13285.15
No. 10301.65
No. 9859.50
No. 12893.65
No. 12615.75
No. 15926.65
No. 25.00
No. 40.00
No. 1500.00
No. 150.00
Rmt. 1050.00
Rmt. 160.00
Rmt. 120.00
Rmt. 160.00
Rmt. 120.00
Rmt. 207.00
Rmt. 135.00
Rmt. 225.00
Rmt. 185.00
Rmt. 320.00
Rmt. 200.00
Rmt. 450.00
Rmt. 390.00
Rmt. 550.00
Rmt. 775.00
Rmt. 450.00
Gross 300.00
Gross 200.00
Doz. 288.00
Doz. 420.00
Doz. 480.00
Doz. 1080.00
Doz. 120.00
Doz. 216.00
Doz. 288.00
Doz. 432.00
Doz. 480.00
Doz. 1440.00
Doz. 132.00
Doz. 216.00
Doz. 300.00
Doz. 432.00
Doz. 480.00
Doz. 1080.00
Doz. 132.00
Doz. 216.00
Doz. 504.00
Doz. 720.00
Doz. 660.00
Doz. 1440.00
Doz. 288.00
Doz. 360.00
Doz. 840.00
Doz. 840.00
Doz. 1440.00
Doz. 2220.00
Doz. 480.00
No. 450.00
No. 270.00
No. 450.00
No. 1500.00
Kg. 90.00
Kg. 0.00
Kg. 16.00
No. 40.00
Kg. 318.00
Rmt. 280.00
No. 600.00
No. 500.00
No. 250.00
No. 6.00
No. 800.00
No. 950.00
No. 242.00
No. 150.00
No. 180.00
Rmt. 263.00
Rmt. 158.00
No. 160.00
No. 130.00
No. 160.00
No. 200.00
No. 350.00
No. 70.00
No. 160.00
No. 225.00
Rmt. 275.00
Rmt. 190.00
Rmt. 85.00
No. 50.00
No. 80.00
No. 60.00
No. 150.00
No. 170.00
No. 150.00
No. 160.00
No. 80.00
No. 350.00
No. 480.00
No. 260.00
No. 430.00
No. 86.65
No. 150.00
No. 105.00
No. 35.00
No. 45.00
No. 55.00
No. 60.00
No. 70.00
No. 80.00
No. 90.00
Kg. 30.00
No. 2300.00
No. 130.00
No. 220.00
No. 280.00
No. 430.00
No. 650.00
No. 1460.00
No. 2500.00
Rmt. 90.00
Rmt. 120.00
Rmt. 360.00
No. 140.00
No. 3300.00
No. 850.00
No. 1000.00
No. 497.00
No. 786.00
No. 750.00
No. 19000.00
No. 1200.00
No. 1800.00
No. 2900.00
No. 6900.00
No. 8000.00
No. 13700.00
No. 500.00
No. 1600.00
No. 1400.00
No. 750.00
No. 700.00
No. 251.00
No. 300.00
No. 375.00
No. 500.00
No. 750.00
No. 1000.00
No. 2500.00
No. 3500.00
No. 1400.00
No. 1450.00
No. 2225.00
No. 950.00
No. 1200.00

Ltr. 205.00
Kg. 78.00
Rmt. 65.00
Sqm. 325.00
Mili Ltr. 93.00
Ltr. 480.00
Sqm. 140.00
Sqm. 150.00
Kg. 54.00
M.T. 58000.00
Ltr. 255.00
Ltr. 425.00
Kg. 250.00
Kg. 272.00
Kg. 15.00
Kg. 140.00
Ltr. 360.00
Sqm. 90.00
Cori 1300.00

Cori 1700.00

Cori 1300.00

Cori 1700.00

Kg. 280.00
Kg. 138.00
Kg. 148.00
No. 50.00
No. 150.00
Ltr. 40.00
Kg. 55.00
Pair 60.00
No. 100.00
Pair 350.00
No. 550.00
Unit Per Rate for 2013-14 (in Rs.)
Day 450.00
Day 450.00
Day 600.00
Day 300.00
Day 400.00
Day 350.00
Day 350.00
Day 500.00
Day 650.00
Day 550.00
Day 450.00
Day 350.00
Day 400.00
Day 500.00
Day 350.00
Day 600.00
Day 500.00
Day 375.00
Day 400.00
Day 350.00
Day 300.00
Day 350.00
No. 20.00
Day 450.00
Day 650.00
Day 500.00
Day 400.00
Day 700.00
Day 275.00
Day 300.00
Day 300.00
Day 350.00
Day 400.00
Day 400.00
Day 400.00
Day 350.00
Day 500.00
Day 400.00
Day 900.00
Day 450.00
Day 750.00
Day 500.00
Day 400.00
Day 350.00
Day 350.00
Day 350.00
Day 300.00
Day 350.00
Day 400.00
Day 400.00
Day 350.00
Day 450.00
Day 300.00
Day 500.00
Day 450.00
No. 20.00

Unit Per Rate for 2013-14 (in Rs.)


Hour 75.00
Hour 50.00
Day 86.00
Hour 590.00
Day 1496.00
Day 172.00
Day 35.00
Hour 196.00
Hour 124.00
Hour 100.00
Day 185.00
Day 400.00
Smt. 20.00
Day 500.00
Day 6200.00
Day 4762.00
Day 4280.00
Day 5713.00
Day 4110.00
Day 7015.00
Day 332.00
Day 130.00
Hour 70.00
Hour 79.00
Hour 95.00
Hour 152.00
Hour 196.00
Cmt. 155.00
Steps 32.00
Hour 590.00
Day 771.00
Day 960.00
Day 825.00

Frequency
Test per 50 M.t. Above six testes
shall be carried.

1 Test for every day work

1 Test per 100 m3


1 Test per 200 m3

1 Test per 200 m3


1 Test per 200 m3
1 Test per for Each Source
1 Test per for Each Source
1 Test per 200 m3
1 Test per 25 m3

1 Test per for Each Source


1 Test per for Each day
1 Test per for Each day work
1 Test per for Each day work

For each 50000 Nos bricks Above


three test are to be carried out

For 2000 Nos of Tiles above three


tests are to be carried out

1 Test- 6 Tiles per 2000 Nos.


1 Concrete Mix Design for each
grade fo concrete per every per
hour
1 Set (3 Nos.)
2 Set (3 Nos.)
3 Set (3 Nos.)
4 Set (3 Nos.)
4+1 additional set per 50 m3

2 Test per 3000 m3


Test per 3000 m3
Test per 3000 m3
Test per 3000 m3
Test per 3000 m3

1 test per Source


1 test per Source

1 test per Source


2 test per Source

One test for every 5.0 MT or part


thereof for each diameter.

Test Rate Sanctioned Rs.

1 Test 2800.00

1 Test 2000.00
1 Test 500.00
1 Test 900.00
1 Test 900.00
1 Test 600.00
1 Test 1900.00
1 Test 275.00

1 Test 12000.00
1 Test 12000.00

1 Test 1000.00
1 Test 600.00
1 Test 325.00
1 Test 375.00
1 Test 650.00

1 Test 1600.00

1 Test 1900.00
1 Test 1250.00
1 Test 600.00
1 Test 1000.00

1 Test 1250.00
1 Test 1000.00

1 Test 1150.00
1 Test 800.00

1 Test 500.00
1 Test 10000.00
1 Test 600.00
1 Test 1250.00
1 Mix Design 12000.00
1 Test 2200.00

Per Km 15.00

1 Test 3000.00

1 Test 500.00

1 Test 1500.00

1 Test 500.00
1 Test 325.00
1 Test 850.00
1 Test 1400.00
1 Test 3900.00
1 Test 2000.00

Per Km 15.00
Per Km 54.00
1 Test 900.00
1 Test 600.00
1 Test 1700.00
1 Test 25000.00
1 Test 750.00

1 Test 2300.00
1 Test 1500.00
1 Test 700.00
1 Test 1200.00
1 Test ...

1 Test 750.00
1 Test 7500.00
1 Mix Design 12000.00
1 Mix Design 5500.00
1 Test 500.00
1 Test 2500.00
1 Test 1300.00
1 Test 900.00
1 Test 900.00
1 Test 450.00
1 Test 2200.00

Per Km 15.00

1 Test 450.00
1 Test 300.00
1 Test 450.00

1 Test 1500.00

1 Test 850.00

1 Test 800.00

1 Test 2000.00

1 Test 2600.00

1 Test 400.00

1 Test 1200.00

1 Test 500.00
1 Test 600.00

1 Test 700.00

1 Test 550.00
400.00

1 Test 550.00
1 Test 300.00

1 Test 200.00
1 Test 250.00

1 Test 200.00
1 Test 900.00
1 Test 2500.00
1 Test 450.00
1 Test 1900.00
1 Test 250.00
1 Test 1200.00

1 Test 900.00
1 Test 1200.00

1 Test 3100.00

1 Test 3100.00
1 Test 900.00
1 Test 800.00
1 Test 800.00
1 Test 650.00

1 Test 650.00
1 Test 600.00
1 Test 250.00
1 Test 400.00
1 Test 400.00
1 Test 850.00

1 Test 3200.00

Per Km 560.00
Per Km 1120.00
Per Km 560.00
Per Km 15.00

Per Km 11300.00

1 Point 150.00
1 Point 250.00

Unit Per Rate for 2013-14 (in Rs.)


Sqm 25500.00
Rmt. 18000.00
Lum Sum
Lum Sum
Lum Sum
Lum Sum
Lum Sum
Lum Sum

Unit Cement in bags Sand in M3


M3 8.00 0.425

Unit Cement in bags Screened Sand in M3

M3 2.60 0.47
M3 3.40 0.47
M3 4.40 0.47
M3 6.40 0.445
M3 7.20 0.425
M3 7.60 0.47o
M3 8.00 0.47o
Unit Cement in bags Screened Sand in M3

M3 7.20 0.47o
M3 7.60 0.47o
M3 8.00 0.47o
M3 8.50 0.47o
M3 9.00 0.47o
M3 0.06 0.015
M3 0.22 0.123

Unit Cement in bags Screened Sand in M3


M3 1.58 0.32

M3 1.58 0.32
M3 1.12 0.32
M3 1.58 0.32
M3 0.26 0.034

Unit Cement in bags Screened Sand in M3


M3 1.70 0.35
M3 2.00 0.35
M3 1.70 0.35
Unit Cement in bags Screened Sand in M3
M3 1.70 0.35
M3 1.70 0.35
Unit Cement in bags Screened Sand in M3

M2 0.19 0.019
M3 0.55 0.07
M3 2.20 0.23
M2 2.20 0.024
M2 0.27 0.028

Unit Cement in bags Screened Sand in M3


M2 0.o45 0.0076
M2 0.07 0.0076
M2 0.09o 0.015
M2 0.11 0.015
M2 0.14 0.015
M2 0.17 0.025
M2 o.145 0.025
M2 0.17 0.024
M2 o.217 0.31
M2 0.25 0.033
M2 0.25 0.021
M2 0.30 0.015
M2 0.30 0.03o
M2 0.o25 0.003
M2 0.05o 0.005
M2 0.04o 0.004
M2 0.03o 0.003
Bd/M: PAVING AND FLOORING

Unit Cement in bags Screened Sand in M3

M2 o.135 0.222
M2 0.14 0.022
M2 0.15 0.022
M2 0.10 0.022
M2 o.135 0.022

M2 o.135 0.022

M2 o.185 0.02o

M2 o.334 0.02o
M2 o.406 0.025
M2 o.300 0.018
M2 0.37 0.022
M2 0.14 0.02
M2 0.19 0.02
M2 0.14 0.02
M2 0.19 0.02
M2 0.20 0.02

M2 0.22 0.02

M2 0.20 0.02
M2 0.22 0.02
M2 0.15 0.02

M2 0.19 0.02

M2 0.14 0.022
M2 0.18 0.02

M2 0.20 0.0136
M2 0.20 0.02
M2 0.30 0.024

M2 0.19 0.02

M2 0.19 0.02
M2 0.19 0.02

M2 0.19 0.02
M2 0.19 0.02
M2 0.19 0.02
M2 0.15 0.02

M2 0.15 0.02
M2 0.10 0.005
M2 0.14 0.02
M2 0.10 0.2
M2 .. 0.085
M2 0.20 0.02
M2 0.22 0.02
SUPPLY & SANITARY

Unit Cement in bags Sand in M3


No 0.20 0.02
No 0.25 0.02
No 0.25 0.02
No 0.10 0.01
No 0.10 0.01
No 0.15 0.02
Rmt. 0.10 0.02
No 0.10 0.01
No 0.10 0.01
No 0.10 0.01
Rmt. o.007 ..
Rmt. 0.05 ..
Rmt. o.007 ..
Rmt. o.007 ..
Rmt. o.035 0.0015
Rmt. o.045 0.0015
Rmt. 0.08 0.0015
Rmt. o.034 ..
Unit Cement in bags Screened Sand in M3
No 2.33 0.35
No 3.53 0.54
No 3.90 0.57
No 6.70 ..
Course Aggregate
40mm in M3 20 mm in M3 12/10 mm in M3
0.70 0.24 ..
0.70 0.24 ..
0.70 0.24 ..
0.70 0.22 0.11
.. 0.67 0.22
.. 0.67 0.22
.. 0.67 0.22
Course Aggregate
40 mm in M3 20 mm in M3 12/10 mm in M3
.. 0.55 0.27
.. 0.55 0.27
.. 0.55 0.27
.. 0.55 0.27
.. 0.55 0.27
.. .. ..
.. .. ..

Bricks Nos M.S. Bars in Kg.


475.00 ..

475.00 ..
475.00 ..
475.00 ..
57.00 1.76

Trap rubble in M3 Conner/ Quins in Nos


1.16 2
1.16 2
1.16 2
Trap rubble in M3 Conner/ Quins in Nos Trap Header in Nos Khandki in Nos
0.35 2 7 50
0.35 2 7 50
Course Aggregate
20mm in m3 12/10 mm in m3
..
Brick Bat 0.080 ..
Brick Bat 1.00 ..
.. ..
.. ..

Fine aggregate in M3
..
..
..
..
..
..
..
..
..
..
0.o12
0.o15
..
..
..
..
..

Metal
20mm in m3 12/10 mm in m3

o.023 o.007
o.028 o.010
o.027 0.09o
0.03 0.011
0.0272
Bricks in Nos Metal in Cum.
350.00 0.194
527.00 0.3
450.00 0.45
.. ..

S-ar putea să vă placă și