Sunteți pe pagina 1din 11

RTM Calculations

Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.1 DESCRIPTION OF CONSTRUCTION

The piperack: 10 m span RC piperack structure, 15 bays at 6 m c/c orientated E/W.


RC frames connected longitudinally, TOC EL +105.750 and +111.500.
TOS EL +108.250 and +103.250
RC column supported on a pile cap, modelled as a spring support.
Pile caps are connected by a foundation slab of 3.0 m wide
The pipe layers: EL.s + 104.500, + 107.500 and + 110.250.
Intermediate steel is provided in tranverse direction to similar levels

Shading indicate Platforms


Bold Lines refer to RC sections Safety Valve Platform

y
x

z
Steelwork Support
Steelwork Support Structure B
Structure A

E Steelwork Support
1471 Structure C

N
4576

E
1561 N
4571

N
4561
N
4554

Page 1 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.2 STRUCTURAL MODEL


E. E.
1471 SLIDING CONNECTION 1555

TOS EL +124.090
TOS EL +120.340 TOS EL +120.475
Intermediate Sections not shown
fabricated from HE300A
TOS EL +116.975

TOS EL +113.570
TOS EL +111.125 900dp x 700W
TOS EL +110.400
TOS EL +108.250 TOS EL +108.250
HE400A

900dp x 700W

700 x 700
TOS EL +104.500
TOS EL +103.250
HPP EL +100.000

Section on N.4576.0 SLIDING CONNECTION Section on E.1471.0 Section on E.1495.0


TOS EL +131.500 E. With typical sections
E. TOS EL +129.750 1561
1471

TOS EL +124.350

TOS EL +120.340
TOS EL +118.800

TOC EL +114.000
TOC EL +111.500
HE240A (typ)
TOS EL +108.250
TOC EL +105.750
HE240A (typ)
TOS EL +103.250

Section on N.4571.0 Section on E.1477.0 Section on E.1501.0

E.
1471
Concrete components
Columns 700 x 700
Transverse beams 700W x 900 dp
Longitudinal beams 500W x 700 dp

Section on E.1507.0
Section on E.1483.0
Section on N.4561.0

E.
1471

Section on E.1489.0 Section on E.1513.0


Section on N.4556.0

Section on E.1531.0 Section on E.1537.0 Section on E.1543.0 Section on E.1549.0

Page 2 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.3 LOADING
2.3.1 Pipe Loads
UDL Piping loads Empty Operation Test
Transverse
TOC EL +104.500 1.5 kN/m² 3.0 kN/m² 3.0 kN/m²
TOS EL +107.500 1.5 kN/m² 3.0 kN/m² 3.0 kN/m²
TOS EL +110.500 1.5 kN/m² 3.0 kN/m² 3.0 kN/m²
Longitudinal
TOC EL +103.250 0.75 kN/m² 1.5 kN/m² 1.5 kN/m²
TOS EL +105.750 0.75 kN/m² 1.5 kN/m² 1.5 kN/m²
TOC EL +108.250 0.75 kN/m² 1.5 kN/m² 1.5 kN/m²
TOC EL +111.500 0.75 kN/m² 1.5 kN/m² 1.5 kN/m²
Anchorage Loads (5% Operation Pipe Load)
TOC EL +104.500 - 0.15 kN/m² -
TOS EL +107.500 - 0.15 kN/m² -
TOS EL +110.500 - 0.15 kN/m² -
Friction Loads (5% of Operation Pipe loads; Not transferred to foundation)
Not applied for derivation of Piling Loads

Walkway at TOC EL +114.000, E. 1513.0 to E.1525.0


Dead load 1.0 kN/m² 1.0 kN/m² 1.0 kN/m²
Imposed load - 4.0 kN/m² 4.0 kN/m²

2.3.2 The Aircoolers


Selfweight 10.0 kN/m² 10.0 kN/m² 10.0 kN/m²
Operating load 2.0 kN/m²
Horizontal load 2.0 kN/m
Perimeter Access Walkway
Dead load 1.0 kN/m² 1.0 kN/m² 1.0 kN/m²
Imposed load - 2.5 kN/m² 2.5 kN/m²

2.3.3 The Steel Support Structures


UDL Pipe loads as 2.6
Point Loads (PL) Pipe loads as per Moerdijk Project

Walkway loads as per 2.3.1.


Safety Valve Platform TOS EL +131.500
Steelwork Support Structure A TOS EL +103.060
Steelwork Support Structure B TOS EL +120.340
Steelwork Support Structure C TOS EL +104.100

2.3.4 Equipment
No equipment in the piperack or steel structures.

2.3.5 Wind Loads


In accordance with DEP 34.00.01.30 Gen. Section 4 of the Appendix, a 10-second gust period is used for
all structures (V10 = 18 m/s). Refer to section.

Page 3 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.4 PAVING LOADS


Included only for the piperack foundations.
Steel column loads are applied in paving design.
Average Paving thickness assumed 300 mm.
Generally paving load is assumed for an area 3 m by 6 m onto each column.
Paving Live Load taken to be 10 kN/m 2.
UDL applied = 3 x 10 kN/m = 30 kN/m.
E E
1471 1561

EJ EJ CJ

N
4571
EJ EJ
Ground-bearing slab
Centreline of Piperack in
Unit 10400/10500

EJ EJ
N
4561
EJ 2175 EJ CJ
2001 2029 2057 2085 2145 2205 2235 2265 2295 2351 2379 2407 2431
2115 2323

Piperack Column EJ - Expansion Joint


EJ CJ – Construction Joint

Paving 300 mm

Pilecap 350 mm

Pile

Page 4 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

No of Pilecap Paving
Location Joints Piles DL DL
(In STAAD- KN kN
III)
E.1471 2001 2002 2 25 135
E.1477 2029 2030 2 25 135
E.1483 2057 2058 2 25 135
E.1489 2085 2086 2 25 135
E.1495 2115 2116 2 25 135
E.1501 2145 2146 2 25 135
E.1507 2175 2176 2 25 135
E.1513 2205 2206 2 25 135
E.1519 2235 2236 2 25 135
E.1525 2265 2266 2 25 135
E.1531 2295 2296 2 25 135
E.1537 2323 2324 4 75 135
E.1543 2351 2352 4 75 135
E.1549 2379 2380 2 25 135
E.1555 2407 2408 2 25 135
E.1561 2431 2432 2 25 135

In STAAD III input file, refer to Load Case 1 Selfweight (inc. Pilecap and Paving DL )
Load Case 2 Imposed Paving Loads
2.5 SUPPORT STIFFNESS

No. of Piles 1 2 4
Pilecap Capacity (kN) 835 1020 1670 2040 3340 4080
Lateral Capacity (kN) 40 80 160
Pile Head Disp.(mm) V 14 10 18 13 24 17
Free Head Disp. (mm) H 3.4 3.4 3.4 3.4 3.4 3.4
Effectiveness 1.00 1.00 1.25 1.25 1.67 1.67
Stiffness/pile (MN/m) V 59.6 102.0 46.4 78 34.8 60.0
H 11.8 11.8 11.8 11.8 11.8 11.8
KFX kN/m 11765 11765 18824 18824 28179 28179
KFY kN/m 59643 83500 92778 128462 139167 196471
STAAD-III

KFZ kN/m 11765 11765 18824 18824 28179 28179


KMX kNm/deg - - - - 2429 4189
KMY kNm/deg 411 411 1642 1642
KMZ kNm/deg - - 1619 2739 2429 4189
The effectiveness relates to the pile group behaviour relative to the single pile results
In some instances KFX and/or KFZ may be considered fixed, due to restraining effects of the paving.

Page 5 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

THE PIPERACK
Transverse sections, E. 1471 to E. 1561
Uniformly Distributed Load (UDL)
On main sections
UDL 12 kN/m
UDLpr = 2/3 x 6 m x 3.0 kN/m² = 12.0 kN/m TOC EL +110.250
On intermediate sections UDL 12 kN/m 358
TOS EL +107.000
UDLpr = 1/3 x 6 m x 3.0 kN/m² = 6.0 kN/m
UDL 12 kN/m
Walkway at TOC EL +114.000, E. 1513 to E.1525 TOC EL +104.500

UDLpr = 8./10 x 3 x (4.0 + 1.0) = 12.0 kN/m


y
Longitudinal elevations, N. 4571 and N. 4561
UDLpr = 1/4 x 10 x 1.5 = 3.75 kN/m x For Steel Structure loading
refer to section 2.8.3
Walkway at TOC EL +114.000, E. 1471 to E.1441
UDLpr = 1x (4.0 + 1.0) = 5.0 kN/m Typical Transverse Section
PS node 358 on E.1537.0 refer to Table 1
Anchorage Forces carried on main RC beams in Z-direction
on main sections at TOC EL+104.500, +107.00 and +110.250
UDLa = 0.15 kN/m² x 6 =  0.9 kN/m
Pipe Support Loads
Operation Test
Node Fx Fy Fz Fy
kN kN KN kN
358 -29 -75
380 -17 -57
Piperack

390 -42 -60


420 -26 -57
430 -16 -52
Table 1: Pipe Support Loads For Steel Structure loading
refer to section 2.8.1

E E E
1471 For Steel Structure loading 1513 1561
refer to section 2.8.2

For Aircooler Loads


refer to section 2.7

UDL 5 N/m
TOC EL +114.000
390 380 430 420
UDL 3.75 kN/m
TOC EL +111.500

TOS EL +108.250 UDL 3.75 kN/m

UDL 3.75 kN/m


TOC EL +105.750
UDL 3.75 kN/m
TOS EL +103.250

HPP EL +100.000

y
Elevation on N4561 and N4571
z For Pipe support nodes (only on N.4561) refer to Table 1

Page 6 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.7 THE AIRCOOLERS

Equipment E-10172
Operation/Test Load on columns (including perimeter walkway)
Point loads, Fy 12.0 x 1.5 x 5 + 3.5 x 1.2 x (5 + 3 +1.5) =130 kN
Equipment E-10174
Point loads, Fy 12.0 x 3 x 3 + 3.5 x 1.2 x ( 6 +1.5 x 2) =146 kN
(take 80% for Dead load only)
Operation only on corner columns
Point loads, Fx 2 x 2 x 6 /2 =  12 kN
3 6m

10 m

N.
4561 Walkway around coolers

E.
1516 Plan view on Aircooler

In STAAD III input file, refer to Load Case 6 Aircooler

Page 7 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

2.8 STEELWORK SUPPORT STRUCTURES


2.8.1 Safety Valve Platform

E E HE240A
1531 1549 414
HE300A
376
HE240A

TOS EL +131.500 HE280A HE220A HE280A


HE220A (typ)
TOS EL +129.750 HE320A

HE280A
HE280A
0n N.4571.0

L90x90x9

TOS EL +124.350
x

HE280A
HE280A

Plan on TOS EL +131.500


HE280A
HE280A

z
TOS EL +118.800 E E
1531 1549
HE280A
Stairs on N.4571 Operation
F = 28 kN F =0.3 F
v h v
Test
Access Walkway F = 47 kN (90 kN N4571.0)
on N. 4571 v 60

TOC EL +111.550 373 411

y 374 376 412

Section on N.4561 and N.4571


z All bracing L120x120x12 UNO
200 100 74
All beams HE180A UNO 150

350 300 250 356

N N Plan on TOS EL +129.750


4561 4571

376
TOS EL +131.500 HE260A HE260A HE260A HE260A

350 200 HE300A 300 150 250 100 356 74 HE300A


HE500A HE500A
TOS EL +129.750 42

Braces Braces Braces Braces


HE220A HE260A HE260A HE220A

TOS EL +124.350 HE200A HE200A HE240A HE200A


HE280A

Braces
HE200A

TOS EL +118.800 HE240A HE240A HE240A HE200A

HE240A
Braces
HE240A

HE200A
y
TOC EL +111.550
x
Section on E.1531 Section on E.1537
All bracing HE200A UNO Section on E.1543 Section on E.1549
All bracing HE200A UNO All bracing HE200A UNO

At TOS EL +131.500 Platform Loads. See Table 2.


Imposed as a series of point loads on main beams. No deductions for penetrations

Page 8 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

On N. 4561, Stair loads on columns at E. 1531 and E.1537. Refer to Table 3.


Point loads comprising stair loads and landings applied to columns.

On N.4571, Ladder Access loads principally on column at E.1549.


Point loads of 10 kN at three levels, applied to column.
Pipe Support node numbers are given in sketch. Refer also to Table 4.

UDL
Width
Location m KN/m
E1528.5 0.75 3.8
E1531.0 3.75 18.8
E1537.0 6.00 30
E1543.0 6.00 30
E1549.0 4.05 20.3
E1543.0 1.05 5.3

Table 2: Platform at TOS EL +131.500

Note: Imposed load = 4 kN/m 2


Provide 1 kN/m2 to allow for grating and beams selfweight not included in analysis

TOS EL E.1531 E.1537


+131.500 3.5 x 1.15 x 1.0 4.0
5.0 x 2.55 x 0.75 9.6
13.6
+127.250 3.5 x 2.1 x 1.4 10.3
3.5 x 1.38 x 0.75 3.6
5.0 x 2.55 x 0.75 9.6
5.0 x 1.74 x 0.75 6.5
30.0
+124.350 3.5 x 2.30 x 1.14 9.2
5.0 x 1.74 x 0.75 6.5
5.0 x 1.74 x 0.75 6.5
22.2
+121.450 3.5 x 2.30 x 1.38 11.1
5.0 x 1.74 x 0.75 6.5
5.0 x 1.74 x 0.75 6.5
24.1
+118.800 3.5 x 2.25 x 1.05 8.3 3.5 x 3.0 x 0.65 6.8
3.5 x 1.35 x 1.75 8.3 3.5 x 1.35 x 1.44 6.8
3.5 x 3.0 x 0.65 6.8 3.5 x 1.14 x 1.15 4.6
23.4 5.0 x 0.55 x 0.75 2.1
5.0 x 1.74 x 0.75 6.5
26.8
+117.880 2.1 x 0.54 1.1 2.1 x 0.46 1.0
3.5 x 0.75 x 3.25 x 0.54 4.6 3.5 x 0.75 x 3.25 x 0.46 3.9
5.7 4.9

Table 3 : Stair Loads on N.4561.0

Note: Imposed load on Landing = 2.5 kN/m 2


Imposed Load on Stairs = 4 kN/m2
Provide 1 kN/m2 to allow for grating and beams selfweight not included in analysis.

Page 9 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

Steelwork Support Structure B and C


E. E.
1471 SLIDING CONNECTIONS 1555

TOS EL +124.090 HE200A

TOS EL +120.340 HE300A HE220A

TOS EL +120.475
K-Bracing HE220A
HE140A
TOS EL +116.975
HE300A

TOS EL +113.570
HE300A

HE240A
HE240A
(typ) TOS EL +111.125
TOS EL +108.250 HE200A HE220A HE240A
TOS EL +110.400

HE340A
HE140A
(typ) HE200A
TOS EL +108.250
TOS EL +104.500 HE200A HE300A HE300A HE200A HE200A HE200A
TOS EL +103.250 HE240A
HE200A HE200A (typ)
HPP EL +100.000

Section on N.4576 SLIDING CONNECTION


All Columns HE220A UNO, Structure B
HE260A UNO, Structure C
All Beams HE140A UNO, Structure B
HE260A UNO, Structure C
All Bracing L100x100x10 UNO Support Support
Structure B Structure C

E
TOS EL +124.090
E
25
TOS EL +120.340 TOS EL +120.475
D
140
TOS EL +116.975

TOS EL +113.570
C TOS EL +111.125
TOS EL +110.400
3.8 kN/m TOS EL +108.250
TOS EL +108.250 N
L M S
R P Q B
TOS EL +104.500 A
3.8 kN/m 3.8 kN/m
TOS EL +103.250

HPP EL +100.000
3.8 kN/m

Section on N.4576
3.8 kN/m
G Legends
B Walkway loads Refer to Table 6
5m

N.
4571
N Pipe support loads Refer to Table 7
F
Intermediate Pipe loads (UDL)
Plan at TOS EL +120.340 Walkways

H J K

N.
4571

E.
1477

Plan at TOS EL +104.100


Walkway TOS EL Calculation UDL PL Notes
KN/m kN
A +104.100 5.0 x 2.5 12.5 On Steel beam N.4576
5.0 x 2.5 x 12.0 /4 37.5 Piperack cols E.1477 and E. 1489
5.0 x 2.5 x 12.0 /4 75 Piperack Col E.1483
B +104.100 0.6 x 5.0 3.0 On steel beam N.4576
1.2 x 5.0 6.0 HE200A
C +111.125 1.0 x 5.0 5.0
D +116.975 2.0 x 5.0 10.0
E +120.340 2.5 x 5.0 12.5
Table 6: Walkway Loads

Page 10 of 11
RTM Calculations
Calculations RTM
Client Getrich Development Use in correspondences
Project Deepdown Sands 234 010455
Location Up in the North Dept Job Reference
Subject Piperack design PR-1001 Doc No P23-00445-C101A Rev 0

Calculations continue but is finished for brevity and demonstration

Page 11 of 11

S-ar putea să vă placă și