Sunteți pe pagina 1din 24

Revision Release List:

Safety Control System ProSafe-RS, R4.03

SIL3 compliant HW Components:

Model Name Description Revision Information Report – No. Status


Style Revision No.
SSC10S Safety Control Unit (Single CPU, Vnet) S1 N/A 968/EZ 196.00/05 Valid
SSC10D Safety Control Unit (Dual red. CPU, Vnet) S1 N/A 968/EZ 196.00/05 Valid
SSC50S Safety Control Unit (Single CPU, Vnet/IP) S2 N/A 968/EZ 196.36/14 Valid
SSC50D Safety Control Unit (Dual red. CPU, Vnet/IP) S2 N/A 968/EZ 196.36/14 Valid
SSC57S Safety Control Unit (Single CPU, Vnet/IP-Upstream) S1 N/A 968/EZ 196.35/14 Valid
SSC57D Safety Control Unit (Dual red. CPU, Vnet/IP-Upstream) S1 N/A 968/EZ 196.35/14 Valid
SSC60S Safety Control Unit (Single CPU, Vnet/IP) S2 N/A 968/EZ 196.36/14 Valid
SSC60D Safety Control Unit (Dual red. CPU, Vnet/IP) S2 N/A 968/EZ 196.36/14 Valid
S2SC70S Safety Control Unit (Single CPU, for N-IO/FIO) S1 N/A 968/EZ 196.39/16 Valid
S2SC70D Safety Control Unit (Dual red. CPU, for N-IO/FIO) S1 N/A 968/EZ 196.39/16 Valid
SNB10D Safety Node Unit S2 N/A 968/EZ 196.08/06 Valid
SCP401-11 Processor Module for SSC10S/D, Vnet S1 U:8, H1:1, H2:2, F1:1, F2:2, F3:0, F4:5 968/EZ 196.40/16 Valid
Processor Module for SSC10S/D, Vnet 968/EZ 196.40/16 Valid
SCP401-51 S1 U:8, H1:1, H2:2, F1:1, F2:2, F3:0, F4:5
with no explosion protection
Processor Module for SSC10S/D, Vnet 968/EZ 196.40/16 Valid
SCP401-E1 S1 U:8, H1:1, H2:2, F1:1, F2:2, F3:0, F4:5
with explosion protection
SCP451-11 Processor Module for SSC50S/D, SSC57S/D, Vnet/IP S1 U:10, H1:1, H2:6, F1:27, F2:3, F3:0, F4:6 968/EZ 196.43/17 Valid
Processor Module for SSC50S/D, SSC57S/D, Vnet/IP 968/EZ 196.43/17 Valid
SCP451-51 S1 U:10, H1:1, H2:6, F1:27, F2:3, F3:0, F4:6
with no explosion protection
Processor Module for SSC50S/D, SSC57S/D, Vnet/IP 968/EZ 196.43/17 Valid
SCP451-E1 S1 U:10, H1:1, H2:6, F1:27, F2:3, F3:0, F4:6
with explosion protection
Processor Module for SSC50S/D, SSC57S/D, Vnet/IP 968/EZ 196.43/17 Valid
SCP451-53 S1 U:10, H1:0, H2:6, F1:27, F2:3, F3:0, F4:6
with no explosion protection, RoHS Directive
Processor Module for SSC50S/D, SSC57S/D, Vnet/IP 968/EZ 196.43/17 Valid
SCP451-E3 S1 U:10, H1:0, H2:6, F1:27, F2:3, F3:0, F4:6
with explosion protection, RoHS Directive
Manufacturer:
Yokogawa Electric Corporation Page 1 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SCP461-11 Processor Module for SSC60S/D, S2SC70S/D, Vnet/IP S2 U:1, H1:2, H2:6, F1:27, F2:3, F3:5, F4:2 968/EZ 196.43/17 Valid
Processor Module for SSC60S/D, S2SC70S/D, Vnet/IP
SCP461-51 S2 U:1, H1:2, H2:6, F1:27, F2:3, F3:5, F4:2 968/EZ 196.43/17 Valid
with no explosion protection
Processor Module for SSC60S/D, S2SC70S/D, Vnet/IP
SCP461-E1 S2 U:1, H1:2, H2:6, F1:27, F2:3, F3:5, F4:2 968/EZ 196.43/17 Valid
with explosion protection
SAI143-S03 Analog Input Module (4 to 20mA) S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
Analog Input Module (4 to 20mA)
SAI143-S53 S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Analog Input Module (4 to 20mA)
SAI143-SE3 S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection
Analog Input Module (4 to 20mA)
SAI143-S33 S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter
Analog Input Module (4 to 20mA)
SAI143-S63 S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Analog Input Module (4 to 20mA)
SAI143-SF3 S4 U:0, H1:1, H2:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection
SAI143-H03 Analog Input Module (4 to 20mA, HART) S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
Analog Input Module (4 to 20mA, HART)
SAI143-H53 S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with no explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-HE3 S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-H33 S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with signal cable adapter
Analog Input Module (4 to 20mA, HART)
SAI143-H63 S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-HF3 S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 2 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Analog Input Module (4 to 20mA, HART)


SAI143-H0C S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
high-density installation
Analog Input Module (4 to 20mA, HART)
SAI143-H5C S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
high-density installation, with no explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-HEC S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
high-density installation, with explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-H3C S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with signal cable adapter, high-density installation
Analog Input Module (4 to 20mA, HART)
SAI143-H6C with signal cable adapter, high-density installation, S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with no explosion protection
Analog Input Module (4 to 20mA, HART)
SAI143-HFC with signal cable adapter, high-density installation, S4 U:0, H1:4, H2:4, F1:3, F2:3 968/EZ 196.43/17 Valid
with explosion protection
SAV144-S03 Analog Input Module (1 to 5V / 1 to 10V) S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
Analog Input Module (1 to 5V / 1 to 10V)
SAV144-S53 S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
with no explosion protection
Analog Input Module (1 to 5V / 1 to 10V)
SAV144-SE3 S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
with explosion protection
Analog Input Module (1 to 5V / 1 to 10V)
SAV144-S33 S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter
Analog Input Module (1 to 5V / 1 to 10V)
SAV144-S63 S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter, with no explosion protection
Analog Input Module (1 to 5V / 1 to 10V)
SAV144-SF3 S2 U:2, H1:1 H2:1, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter, with explosion protection
Analog Input Module (TC/mV)
SAT145-S33 S1 U:1, H1:0, H2:2, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter
Analog Input Module (TC/mV)
SAT145-S63 S1 U:1, H1:0, H2:2, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter, with no explosion protection
Analog Input Module (TC/mV)
SAT145-SF3 S1 U:1, H1:0, H2:2, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 3 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Analog Input Module (RTD)


SAR145-S33 S1 U:1, H1:0, H2:3, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter
Analog Input Module (RTD)
SAR145-S63 S1 U:1, H1:0, H2:3, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter, with no explosion protection
Analog Input Module (RTD)
SAR145-SF3 S1 U:1, H1:0, H2:3, F1:2, F2:2 968/EZ 196.42/17 Valid
with signal cable adapter, with explosion protection
SAI533-H03 Analog Output Module (4 to 20mA, HART) S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
Analog Output Module (4 to 20mA, HART)
SAI533-H53 S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
with no explosion protection
Analog Output Module (4 to 20mA, HART)
SAI533-HE3 S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
with explosion protection
Analog Output Module (4 to 20mA, HART)
SAI533-H33 S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter
Analog Output Module (4 to 20mA, HART)
SAI533-H63 S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter, with no explosion protection
Analog Output Module (4 to 20mA, HART)
SAI533-HF3 S1 U:2, H1:3, H2:6, F1:3, F2:3 968/EZ 196.40/16 Valid
with signal cable adapter, with explosion protection
SDV144-S13 Digital Input Module (contact input) S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
Digital Input Module (contact input)
SDV144-S53 S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Digital Input Module (contact input)
SDV144-SE3 S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection
Digital Input Module (contact input)
SDV144-S33 S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter
Digital Input Module (contact input)
SDV144-S63 S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Digital Input Module (contact input)
SDV144-SF3 S4 U:2, H1:3, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 4 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Digital Input Module (contact input)


SDV144-S1C S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation
Digital Input Module (contact input)
SDV144-S5C S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation, with no explosion protection
Digital Input Module (contact input)
SDV144-SEC S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation, with explosion protection
Digital Input Module (contact input)
SDV144-S3C S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, high-density installation
Digital Input Module (contact input)
SDV144-S6C with signal cable adapter, high-density installation, S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Digital Input Module (contact input)
SDV144-SFC with signal cable adapter, high-density installation, S4 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection

Digital Output Module (24V DC)


SDV521-S33 S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter
Digital Output Module (24V DC)
SDV521-S63 S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Digital Output Module (24V DC)
SDV521-SF3 S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection
Digital Output Module (24V DC)
SDV521-S3C S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, high-density installation
Digital Output Module (24V DC)
SDV521-S6C with signal cable adapter, high-density installation, S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC)
SDV521-SFC with signal cable adapter, high-density installation, S3 U:2, H1:2, H2:3, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection
Digital Output Module (100-120VAC)
SDV526-S33 S1 U:0, H1:0, H2:1, H3:0, F1:1, F2:1 968/EZ 196.18/08 Valid
with signal cable adapter

Manufacturer:
Yokogawa Electric Corporation Page 5 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SDV531-S13 Digital Output Module (24V DC) S1 U:0, H1:2, H2:1, H3:1, F1:3, F2:3 968/EZ 196.00/05 Valid
SDV531-S23 Digital Output Module (24V DC) S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
Digital Output Module (24V DC)
SDV531-S53 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC)
SDV531-SE3 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with explosion protection
Digital Output Module (24V DC)
SDV531-S33 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter
Digital Output Module (24V DC)
SDV531-S63 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Digital Output Module (24V DC)
SDV531-SF3 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection
SDV531-L23 Digital Output Module (24V DC) S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
Digital Output Module (24V DC)
SDV531-L53 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC)
SDV531-LE3 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with explosion protection
Digital Output Module (24V DC)
SDV531-L33 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter
Digital Output Module (24V DC)
SDV531-L63 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Digital Output Module (24V DC)
SDV531-LF3 S4 U:3, H1:4, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection
Digital Output Module (24V DC)
SDV531-L2C S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
high-density installation
Digital Output Module (24V DC)
SDV531-L5C S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
high-density installation, with no explosion protection
Digital Output Module (24V DC)
SDV531-LEC S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
high-density installation, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 6 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Digital Output Module (24V DC)


SDV531-L3C S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with signal cable adapter, high-density installation
Digital Output Module (24V DC)
SDV531-L6C with signal cable adapter, high-density installation, S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC)
SDV531-LFC with signal cable adapter, high-density installation, S4 U:3, H1:3, H2:2, H3:1, F1:2, F2:2 968/EZ 196.43/17 Valid
with explosion protection
SDV541-S23 Digital Output Module (24V DC – 16 channels) S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
Digital Output Module (24V DC – 16 channels)
SDV541-S53 S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-SE3 S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-S33 S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter
Digital Output Module (24V DC – 16 channels)
SDV541-S63 S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with no explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-SF3 S3 U:3, H1:5, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, with explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-S2C S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation
Digital Output Module (24V DC – 16 channels)
SDV541-S5C S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation, with no explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-SEC S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
high-density installation, with explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-S3C S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with signal cable adapter, high-density installation
Digital Output Module (24V DC – 16 channels)
SDV541-S6C with signal cable adapter, high-density installation, S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with no explosion protection
Digital Output Module (24V DC – 16 channels)
SDV541-SFC with signal cable adapter, high-density installation, S3 U:2, H1:3, H2:2, H3:1, F1:1, F2:1 968/EZ 196.43/17 Valid
with explosion protection
Manufacturer:
Yokogawa Electric Corporation Page 7 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Digital Output Module (48V DC – 8 channels)


SDV53A-S33 S2 U:1, H1:0, H2:2, H3:0, F1:1, F2:1 968/EZ 196.38/15 Valid
with signal cable adapter
Digital Output Module (48V DC – 8 channels)
SDV53A-S63 S2 U:1, H1:0, H2:2, H3:0, F1:1, F2:1 968/EZ 196.38/15 Valid
with signal cable adapter, with no explosion protection
Digital Output Module (48V DC – 8 channels)
SDV53A-SF3 S2 U:1, H1:0, H2:2, H3:0, F1:1, F2:1 968/EZ 196.38/15 Valid
with signal cable adapter, with explosion protection
S2MMM843-
Analog Digital I/O Module (16 channels) S1 U:0, H1:0, H2:0, F1:2, F2:4, F3:4 968/EZ 196.42/17 Valid
SS1030
S2MMM843- Analog Digital I/O Module (16 channels),
S1 U:0, H1:0, H2:0, F1:2, F2:4, F3:4 968/EZ 196.42/17 Valid
SS1130 with explosion protection
S2MDV843-
Digital I/O Module (16 channels) S1 U:0, H1:0, H2:0, F1:2, F2:4, F3:4 968/EZ 196.43/17 Valid
0S1030
S2MDV843- Digital I/O Module (16 channels)
S1 U:0, H1:0, H2:0, F1:2, F2:4, F3:4 968/EZ 196.43/17 Valid
0S1130 with explosion protection
SCB100-S0 Wiring Check Adapter S2 N/A 968/EZ 196.11/07 Valid
SCB110-S0 Wiring Check Adapter S2 N/A 968/EZ 196.11/07 Valid
Analog Terminal Board (16-channels x 2)
SEA4D-01 S1 N/A 968/EZ 196.30/11 Valid
without surge absorber
Analog Terminal Board (16-channels x 2)
SEA4D-06 S1 N/A 968/EZ 196.36/14 Valid
without surge absorber, with no explosion protection
Analog Terminal Board (16-channels x 2)
SEA4D-0F S1 N/A 968/EZ 196.36/14 Valid
without surge absorber, with explosion protection
Analog Terminal Board (16-channels x 2)
SEA4D-11 S1 N/A 968/EZ 196.30/11 Valid
with surge absorber
Analog Terminal Board (16-channels x 2)
SEA4D-16 S1 N/A 968/EZ 196.36/14 Valid
with surge absorber, with no explosion protection
Analog Terminal Board (16-channels x 2)
SEA4D-1F S1 N/A 968/EZ 196.36/14 Valid
with surge absorber, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 8 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Digital Terminal Board (4-channels x 4)


SED2D-01 S2 N/A 968/EZ 196.30/11 Valid
without surge absorber
Digital Terminal Board (4-channels x 4)
SED2D-06 S2 N/A 968/EZ 196.36/14 Valid
without surge absorber, with no explosion protection
Digital Terminal Board (4-channels x 4)
SED2D-0F S2 N/A 968/EZ 196.36/14 Valid
without surge absorber, with explosion protection
Digital Terminal Board (4-channels x 4)
SED2D-11 S2 N/A 968/EZ 196.30/11 Valid
with surge absorber
Digital Terminal Board (4-channels x 4)
SED2D-16 S2 N/A 968/EZ 196.36/14 Valid
with surge absorber, with no explosion protection
Digital Terminal Board (4-channels x 4)
SED2D-1F S2 N/A 968/EZ 196.36/14 Valid
with surge absorber, with explosion protection
Digital Terminal Board (48VDC, 8-channels x 4)
SED3D-A1 S1 N/A 968/EZ 196.30/11 Valid
Digital Terminal Board (48VDC, 8-channels x 4),
SED3D-A6 S1 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Digital Terminal Board (48VDC, 8-channels x 4),
SED3D-AF S1 N/A 968/EZ 196.36/14 Valid
with explosion protection
Digital Terminal Board (16-channels x 2)
SED4D-01 S2 N/A 968/EZ 196.30/11 Valid
without surge absorber
Digital Terminal Board (16-channels x 2)
SED4D-06 S2 N/A 968/EZ 196.36/14 Valid
without surge absorber, with no explosion protection
Digital Terminal Board (16-channels x 2)
SED4D-0F S2 N/A 968/EZ 196.36/14 Valid
without surge absorber, with explosion protection
Digital Terminal Board (16-channels x 2)
SED4D-11 S2 N/A 968/EZ 196.30/11 Valid
with surge absorber
Digital Terminal Board (16-channels x 2)
SED4D-16 S2 N/A 968/EZ 196.36/14 Valid
with surge absorber, with no explosion protection
Digital Terminal Board (16-channels x 2)
SED4D-1F S2 N/A 968/EZ 196.36/14 Valid
with surge absorber, with explosion protection
Digital Terminal Board (100-120VAC, 4-channels x 4)
SWD2D-21 S1 N/A 968/EZ 196.30/11 Valid

Manufacturer:
Yokogawa Electric Corporation Page 9 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SBA4D-01 Analog Terminal board (16-channels x 1) S1 N/A 968/EZ 196.31/11 Valid


Analog Terminal board (16-channels x 1),
SBA4D-06 S1 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Analog Terminal board (16-channels x 1),
SBA4D-0F S1 N/A 968/EZ 196.36/14 Valid
with explosion protection
SBT4D-01 Analog Terminal board (TC/mV, 16-channels x 1) S1 N/A 968/EZ 196.31/11 Valid
Analog Terminal board (TC/mV, 16-channels x 1),
SBT4D-06 S1 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Analog Terminal board (TC/mV, 16-channels x 1),
SBT4D-0F S1 N/A 968/EZ 196.36/14 Valid
with explosion protection
SBR4D-01 Analog Terminal board (RTD, 16-channels x 1) S1 N/A 968/EZ 196.31/11 Valid
Analog Terminal board (RTD, 16-channels x 1),
SBR4D-06 S1 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Analog Terminal board (RTD, 16-channels x 1),
SBR4D-0F S1 N/A 968/EZ 196.36/14 Valid
with explosion protection
SBD2D-01 Digital Terminal Board (4-channels x 1) S2 N/A 968/EZ 196.36/14 Valid
Digital Terminal Board (4-channels x 1),
SBD2D-06 S2 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Digital Terminal Board (4-channels x 1),
SBD2D-0F S2 N/A 968/EZ 196.36/14 Valid
with explosion protection
SBD3D-01 Digital Terminal Board (8-channels x 1) S2 N/A 968/EZ 196.36/14 Valid
Digital Terminal Board (8-channels x 1),
SBD3D-06 S2 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Digital Terminal Board (8-channels x 1),
SBD3D-0F S2 N/A 968/EZ 196.36/14 Valid
with explosion protection
SBD3D-A1 Digital Terminal Board (48VDC, 8-channels x 1) S2 N/A 968/EZ 196.36/14 Valid
Digital Terminal Board (48VDC, 8-channels x 1),
SBD3D-A6 S2 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Digital Terminal Board (48VDC, 8-channels x 1),
SBD3D-AF S2 N/A 968/EZ 196.36/14 Valid
with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 10 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SBD4D-01 Digital Terminal Board (16-channels x 1) S2 N/A 968/EZ 196.36/14 Valid


Digital Terminal Board (16-channels x 1),
SBD4D-06 S2 N/A 968/EZ 196.36/14 Valid
with no explosion protection
Digital Terminal Board (16-channels x 1),
SBD4D-0F S2 N/A 968/EZ 196.36/14 Valid
with explosion protection
S1BB4D-06 Analog Terminal Board (3-wire, 16-channels x 1) S1 N/A 968/EZ 196.39/16 Valid
Analog Terminal Board (3-wire, 16-channels x 1),
S1BB4D-0F S1 N/A 968/EZ 196.42/17 Valid
with explosion protection
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-01030 S2 N/A 968/EZ 196.42/17 Valid
channel), Pressure clamp terminal, Din rail mount
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-01130 channel), Pressure clamp terminal, S2 N/A 968/EZ 196.42/17 Valid
with explosion protection, Din rail mount
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-02030 S2 N/A 968/EZ 196.42/17 Valid
channel), Spring clamp terminal, Din rail mount
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-02130 channel), Spring clamp terminal, S2 N/A 968/EZ 196.42/17 Valid
with explosion protection, Din rail mount
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-11030 S2 N/A 968/EZ 196.42/17 Valid
channel), Pressure clamp terminal
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-11130 channel), Pressure clamp terminal, S2 N/A 968/EZ 196.42/17 Valid
with explosion protection
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-12030 S2 N/A 968/EZ 196.42/17 Valid
channel), Spring clamp terminal
Base Plate with disconnecting terminal (for N-IO, 16-
S2BN1D-12130 channel), Spring clamp terminal, S2 N/A 968/EZ 196.42/17 Valid
with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 11 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

S2BN4D- Base Plate for Barrier (for N-IO, MTL Barrier), Intrinsic
S1 N/A 968/EZ 196.39/16 Valid
100C0 Safety wiring (Left)
S2BN4D- Base Plate for Barrier (for N-IO, MTL Barrier), Intrinsic
S1 N/A 968/EZ 196.39/16 Valid
100D0 Safety wiring (Right)
S2BN4D- Base Plate for Barrier (for N-IO, MTL Barrier), Intrinsic
S1 N/A 968/EZ 196.42/17 Valid
101C0 Safety wiring (Left), with explosion protection
S2BN4D- Base Plate for Barrier (for N-IO, MTL Barrier), Intrinsic
S1 N/A 968/EZ 196.42/17 Valid
101D0 Safety wiring (Right), with explosion protection
S2BN5D- Base Plate for Barrier (for N-IO, P+F Barrier), Intrinsic
S2 N/A 968/EZ 196.42/17 Valid
121C0 Safety wiring (Left)
S2BN5D- Base Plate for Barrier (for N-IO, P+F Barrier), Intrinsic
S2 N/A 968/EZ 196.42/17 Valid
121D0 Safety wiring (Right)

Manufacturer:
Yokogawa Electric Corporation Page 12 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Further HW Components suitable for use to build up safety loops up to SIL3 with ProSafe-RS:

Model Name Description Revision Information Report – No. Status


Style Revision No.

S2NN30D Node Interface Unit (for N-IO) S1 N/A 968/EZ 196.39/16 Valid
FAN Unit for SSC10S/D, SSC50S/D, SSC57S/D,
AIP602 S2 N/A 968/EZ 196.36/14 Valid
SSC60S/D, S2SC70S/D
AIP504-13 Vnet Coupler Unit S1 U:1, H:0 968/EZ 196.32/12 Valid
AIP504-53 Vnet Coupler Unit, with no explosion protection S1 U:1, H:0 968/EZ 196.36/14 Valid
AIP504-E3 Vnet Coupler Unit, with explosion protection S1 U:1, H:0 968/EZ 196.36/14 Valid
100-120V AC Input Power Supply Module
SPW481-13 for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D, S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D
100-120V AC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW481-53 S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with no explosion protection
100-120V AC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW481-E3 S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 13 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

220-240V AC Input Power Supply Module


SPW482-13 for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D, S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D
220-240V AC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW482-53 S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with no explosion protection
220-240V AC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW482-E3 S1 U:2, H:4 968/EZ 196.40/16 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with explosion protection
24VDC Input Power Supply Module
SPW484-13 for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D, S1 U:2, H:0 968/EZ 196.38/15 Valid
SSC60S/D, S2SC70S/D, SNT10D
24VDC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW484-53 S1 U:2, H:0 968/EZ 196.38/15 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with no explosion protection
24VDC Input Power Supply Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SPW484-E3 S1 U:2, H:0 968/EZ 196.38/15 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with explosion protection
S2PW503-
100-240V AC Input Power Supply Module for N-IO S1 U:0, H:0 968/EZ 196.39/16 Valid
S0030
S2PW503- 100-240V AC Input Power Supply Module for N-IO,
S1 U:0, H:0 968/EZ 196.42/17 Valid
S0130 with explosion protection
S2PW504-
24V DC Input Power Supply Module for N-IO S1 U:0, H:1 968/EZ 196.39/16 Valid
S0030
S2PW504- 24V DC Input Power Supply Module for N-IO,
S1 U:0, H:1 968/EZ 196.42/17 Valid
S0130 with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 14 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SNT10D Note Unit for Optical Bus Repeater Module S1 N/A 968/EZ 196.08/06 Valid
Optical ESB Bus Repeater Master Module
SNT401-13 for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D, S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
SSC60S/D, S2SC70S/D, SNT10D
Optical ESB Bus Repeater Master Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SNT401-53 S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with no explosion protection
Optical ESB Bus Repeater Master Module
for SSC10S/D, SNB10D, SSC50S/D, SSC57S/D,
SNT401-E3 S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
SSC60S/D, S2SC70S/D, SNT10D,
with explosion protection
Optical ESB Bus Repeater Master Module
SNT401-5F S1 U:1, H:1, F:0 968/EZ 196.43/17 Valid
for S2EN501, with no explosion protection
Optical ESB Bus Repeater Master Module
SNT401-EF S1 U:1, H:1, F:0 968/EZ 196.43/17 Valid
for S2EN501, with explosion protection
Optical ESB Bus Repeater Master Module for long
SNT411-13 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance
Optical ESB Bus Repeater Master Module for long
SNT411-53 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance, with no explosion protection
Optical ESB Bus Repeater Master Module for long
SNT411-E3 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance, with explosion protection
Optical ESB Bus Repeater Master Module for long
SNT411-5F S2 U:0, H:1, F:0 968/EZ 196.43/17 Valid
distance for S2EN501, with no explosion protection
Optical ESB Bus Repeater Master Module for long
SNT411-EF S2 U:0, H:1, F:0 968/EZ 196.43/17 Valid
distance for S2EN501, with explosion protection
Optical ESB Bus Repeater Master Module for
SNT421-53 S1 U:0, H:1, F:1 968/EZ 196.43/17 Valid
Multimode Fiber, with no explosion protection
Optical ESB Bus Repeater Master Module for
SNT421-E3 S1 U:0, H:1, F:1 968/EZ 196.43/17 Valid
Multimode Fiber, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 15 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Optical ESB Bus Repeater Slave Module


SNT501-13 S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
for SNB10D and SNT10D
Optical ESB Bus Repeater Slave Module
SNT501-53 S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
for SNB10D and SNT10D, with no explosion protection
Optical ESB Bus Repeater Slave Module
SNT501-E3 S1 U:1, H:2, F:1 968/EZ 196.43/17 Valid
for SNB10D and SNT10D, with explosion protection
Optical ESB Bus Repeater Slave Module
SNT501-5F S1 U:1, H:1, F:0 968/EZ 196.43/17 Valid
for S2EN501, with no explosion protection
Optical ESB Bus Repeater Slave Module
SNT501-EF S1 U:1, H:1, F:0 968/EZ 196.43/17 Valid
for S2EN501, with explosion protection
Optical ESB Bus Repeater Slave Module for long
SNT511-13 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance
Optical ESB Bus Repeater Slave Module for long
SNT511-53 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance, with no explosion protection
Optical ESB Bus Repeater Slave Module for long
SNT511-E3 S2 U:0, H:2, F:1 968/EZ 196.43/17 Valid
distance, with explosion protection
Optical ESB Bus Repeater Slave Module for long
SNT511-5F S2 U:0, H:1, F:0 968/EZ 196.43/17 Valid
distance for S2EN501, with no explosion protection
Optical ESB Bus Repeater Slave Module for long
SNT511-EF S2 U:0, H:1, F:0 968/EZ 196.43/17 Valid
distance for S2EN501, with explosion protection
Optical ESB Bus Repeater Slave Module for Multimode
SNT521-53 S1 U:0, H:1, F:1 968/EZ 196.43/17 Valid
Fiber, with no explosion protection
Optical ESB Bus Repeater Slave Module for Multimode
SNT521-E3 S1 U:0, H:1, F:1 968/EZ 196.43/17 Valid
Fiber, with explosion protection
ESB Bus Coupler Module for SSC10S/D, SSC50S/D,
SEC401-11 S3 U:0, H:2 968/EZ 196.43/17 Valid
SSC57S/D, SSC60S/D, S2SC70S/D
ESB Bus Coupler Module for SSC10S/D, SSC50S/D,
SEC401-51 SSC57S/D, SSC60S/D, S2SC70S/D, S3 U:0, H:2 968/EZ 196.43/17 Valid
with no explosion protection
ESB Bus Coupler Module for SSC10S/D, SSC50S/D,
SEC401-E1 SSC57S/D, SSC60S/D, S2SC70S/D, S3 U:0, H:2 968/EZ 196.43/17 Valid
with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 16 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SEC402-21 ESB Bus Coupler Module for SSC60S/D, S2SC70S/D S1 U:0, H:3 968/EZ 196.43/17 Valid
ESB Bus Coupler Module for SSC60S/D, S2SC70S/D,
SEC402-51 S1 U:0, H:3 968/EZ 196.43/17 Valid
with no explosion protection
ESB Bus Coupler Module for SSC60S/D, S2SC70S/D,
SEC402-E1 S1 U:0, H:3 968/EZ 196.43/17 Valid
with explosion protection
SSB401-13 ESB Bus Interface Module for SNB10D S1 U:0, H:5 968/EZ 196.43/17 Valid
ESB Bus Interface Module for SNB10D,
SSB401-53 S1 U:0, H:5 968/EZ 196.43/17 Valid
with no explosion protection
ESB Bus Interface Module for SNB10D,
SSB401-E3 S1 U:0, H:5 968/EZ 196.43/17 Valid
with explosion protection
S2EN402-
N-ESB Bus Coupler Module (for N-IO, 2-Port) S1 U:0, H:0 968/EZ 196.39/16 Valid
S0001
S2EN402- N-ESB Bus Coupler Module (for N-IO, 2-Port),
S1 U:0, H:0 968/EZ 196.42/17 Valid
S0011 with explosion protection
S2EN404-
N-ESB Bus Coupler Module (for N-IO, 4-Port) S1 U:0, H:0 968/EZ 196.39/16 Valid
S0001
S2EN404- N-ESB Bus Coupler Module (for N-IO, 4-Port),
S1 U:0, H:0 968/EZ 196.42/17 Valid
S0011 with explosion protection
S2EN501- N-ESB Bus Module
S1 U:0, H:10 968/EZ 196.42/17 Valid
S00030 (Uplink: N-ESB bus, Downlink: N-ESB Bus)
N-ESB Bus Module
S2EN501-
(Uplink: N-ESB bus, Downlink: N-ESB Bus), S1 U:0, H:10 968/EZ 196.42/17 Valid
S00130
with explosion protection
S2EN501- N-ESB Bus Module
S1 U:0, H:10 968/EZ 196.42/17 Valid
S01030 (Uplink: N-ESB bus, Downlink: Optical ESB Bus 5km)
N-ESB Bus Module
S2EN501-
(Uplink: N-ESB bus, Downlink: Optical ESB Bus 5km), S1 U:0, H:10 968/EZ 196.42/17 Valid
S01130
with explosion protection
S2EN501- N-ESB Bus Module
S1 U:0, H:10 968/EZ 196.42/17 Valid
S02030 (Uplink: N-ESB bus, Downlink: Optical ESB Bus 50km)
N-ESB Bus Module
S2EN501-
(Uplink: N-ESB bus, Downlink: Optical ESB Bus 50km), S1 U:0, H:10 968/EZ 196.42/17 Valid
S02130
with explosion protection
Manufacturer:
Yokogawa Electric Corporation Page 17 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

S2EN501- N-ESB Bus Module


S1 U:0, H:10 968/EZ 196.42/17 Valid
S10030 (Uplink: Optical ESB Bus 5km, Downlink: N-ESB bus)
N-ESB Bus Module
S2EN501-
(Uplink: Optical ESB Bus 5km, Downlink: N-ESB bus), S1 U:0, H:10 968/EZ 196.42/17 Valid
S10130
with explosion protection
S2EN501- N-ESB Bus Module (Uplink: Optical ESB Bus 5km,
S1 U:0, H:10 968/EZ 196.42/17 Valid
S11030 Downlink: Optical ESB Bus 5km)
N-ESB Bus Module (Uplink: Optical ESB Bus 5km,
S2EN501-
Downlink: Optical ESB Bus 5km), S1 U:0, H:10 968/EZ 196.42/17 Valid
S11130
with explosion protection
S2EN501- N-ESB Bus Module (Uplink: Optical ESB Bus 5km,
S1 U:0, H:10 968/EZ 196.42/17 Valid
S12030 Downlink: Optical ESB Bus 50km)
N-ESB Bus Module (Uplink: Optical ESB Bus 5km,
S2EN501-
Downlink: Optical ESB Bus 50km), S1 U:0, H:10 968/EZ 196.42/17 Valid
S12130
with explosion protection
S2EN501- N-ESB Bus Module
S1 U:0, H:10 968/EZ 196.42/17 Valid
S20030 (Uplink: Optical ESB Bus 50km , Downlink: N-ESB bus)
N-ESB Bus Module
S2EN501-
(Uplink: Optical ESB Bus 50km , Downlink: N-ESB S1 U:0, H:10 968/EZ 196.42/17 Valid
S20130
bus), with explosion protection
S2EN501- N-ESB Bus Module (Uplink: Optical ESB Bus 50km,
S1 U:0, H:10 968/EZ 196.42/17 Valid
S21030 Downlink: Optical ESB Bus 5km)
N-ESB Bus Module (Uplink: Optical ESB Bus 50km,
S2EN501-
Downlink: Optical ESB Bus 5km), with explosion S1 U:0, H:10 968/EZ 196.42/17 Valid
S21130
protection
S2EN501- N-ESB Bus Module (Uplink: Optical ESB Bus 50km,
S1 U:0, H:10 968/EZ 196.42/17 Valid
S22030 Downlink: Optical ESB Bus 50km)
N-ESB Bus Module (Uplink: Optical ESB Bus 50km,
S2EN501-
Downlink: Optical ESB Bus 50km), S1 U:0, H:10 968/EZ 196.42/17 Valid
S22130
with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 18 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

RS40-0009CCCCEDBPYY
GRVSW-660FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MACH104-20TX-F
GRVSW-663FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MACH104-20TX-FR
GRVSW-664FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MAR1040-4C4C4C4C9999EM9HPYY
GRVSW-665FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MAR1040-4C4C4C4C9999EMMHPYY
GRVSW-666FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MAR1040-4C4C4C4C9999ELLHPYY
GRVSW-667FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L2SW
MAR1040-4C4C4C4C9999EM9HRY1
GRVSW-668FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW
MAR1040-4C4C4C4C9999EMMHRY1
GRVSW-669FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW
MAR1040-4C4C4C4C9999ELLHRY1
GRVSW-670FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW
MAR1040-4C4C4C4C9999EM9HRY2
GRVSW-671FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW
MAR1040-4C4C4C4C9999EMMHRY2
GRVSW-672FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW
MAR1040-4C4C4C4C9999ELLHRY2
GRVSW-673FA N/A N/A 968/EZ 196.36/14 Valid
Network Switch for Vnet/IP, L3SW

Manufacturer:
Yokogawa Electric Corporation Page 19 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Further interference free HW Components suitable for use with ProSafe-RS:

Model Name Description Revision Information Report – No. Status


Style Revision No.
ALR111-S01 RS-232C Communication Module S1 U:1, H1:7, H2:4, F:3 968/EZ 196.43/17 Valid
RS-232C Communication Module,
ALR111-S51 S1 U:1, H1:7, H2:4, F:3 968/EZ 196.43/17 Valid
with no explosion protection
RS-232C Communication Module,
ALR111-SE1 S1 U:1, H1:7, H2:4, F:3 968/EZ 196.43/17 Valid
with explosion protection
ALR121-S01 RS-422/RS485 Communication Module S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
RS-422/RS485 Communication Module,
ALR121-S51 S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with no explosion protection
RS-422/RS485 Communication Module,
ALR121-SE1 S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with explosion protection
RS-422/RS485 Communication Module
ALR121-S0B S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature
RS-422/RS485 Communication Module
ALR121-S5B S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with no explosion protection
RS-422/RS485 Communication Module
ALR121-SEB S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with explosion protection
RS-422/RS485 Communication Module
ALR121-S53 S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with no explosion protection
RS-422/RS485 Communication Module
ALR121-SE3 S1 U:1, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 20 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

ALE111-S01 Ethernet Communication Module S1 U:3 H1:0, F:3 968/EZ 196.38/15 Valid
Ethernet Communication Module,
ALE111-S51 S1 U:3 H1:0, F:3 968/EZ 196.38/15 Valid
with no explosion protection
Ethernet Communication Module,
ALE111-SE1 S1 U:3 H1:0, F:3 968/EZ 196.38/15 Valid
with explosion protection
Ethernet Communication Module,
ALE111-S53 S1 U:3, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with no explosion protection
Ethernet Communication Module,
ALE111-SE3 S1 U:3, H1:0, F:3 968/EZ 196.38/15 Valid
with temperature, with explosion protection

Manufacturer:
Yokogawa Electric Corporation Page 21 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

SIL3 compliant SW Components:

Model Name Description Revision Information Report – No. Status


Style Revision No.
RS4F1100 Safety Control Function for SCS (SSC50) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1105 Safety Control Function for SCS Simulator (SSC50) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1170 Safety Control Function for SCS (SSC57) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1300 Safety Control Function for SCS (SSC60) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1305 Safety Control Function for SCS Simulator (SSC60) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1500 Safety Control Function for SCS (S2SC70) N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F1505 Safety Control Function for SCS Simulator (S2SC70) N/A 4.03.00 968/EZ 196.43/17 Valid

Further SW Components suitable for use to build up safety loops up to SIL3 with ProSafe-RS:

Model Name Description Revision Information Report – No. Status


Style Revision No.
RS4E5100 Safety System Engineering and Maintenance Function N/A 4.03.00 968/EZ 196.43/17 Valid
Document Map and Safety Manual as part of the
RS4C5400 Software and Electronic Instruction Manual Media - N/A 4.03.00 968/EZ 196.43/17 Valid
RS4CKM

Manufacturer:
Yokogawa Electric Corporation Page 22 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Further interference free SW Components suitable for use with ProSafe-RS:


Model Name Description Revision Information Report – No. Status
Style Revision No.
RS4CKM Software and Electronic Instruction Manual Media N/A 4.03.00 968/EZ 196.43/17 Valid
RS4F3100 Project I/O License N/A 4.03.00 968/EZ 196.43/17 Valid
RS4H2100 SOE Viewer N/A 4.03.00 968/EZ 196.43/17 Valid
RS4H2200 SOE OPC Interface N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5000 Engineering Server Function N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5170 Access Control and Operation History Management N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5210 I/O List Engineering N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5250 Change Management N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5600 CENTUM VP Integration N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5700 FAST/TOOLS Integration N/A 4.03.00 968/EZ 196.43/17 Valid
RS4E5810 iDefine Interface N/A 4.03.00 968/EZ 196.43/17 Valid
RS4C5400 Electronic Instruction Manual N/A 4.03.00 968/EZ 196.43/17 Valid

Released by Manufacturer: Released by Test Institute: Released by Certifier:


Signed:

Toshiki Ogawa Andreas Hesse Heinz Gall


Date: 2017-07-25 2017-07-25 2017-07-25

Manufacturer: Test Institute:


Yokogawa Electric Corporation Page 23 of 24 TÜV Rheinland Industrie Service GmbH
2-9-32 Nakacho A-FS: Automation, Funktionale Sicherheit
Musashino-shi Am Grauen Stein
Tokyo - 180-8750 51105 Köln
Japan Germany
Revision Release List:
Safety Control System ProSafe-RS, R4.03

Document-Revision

Date Version Revisions / Changes Author


2017-07-25 1.0 R4.03.00: Transmitter Power OFF/ON Function, Chattering alarm suppression function, N-IO Function Enhancement, AD Suite Function Enhancement He / A-FS
Improvement for some HW components

Manufacturer:
Yokogawa Electric Corporation Page 24 of 24
2-9-32 Nakacho
Musashino-shi
Tokyo - 180-8750
Japan