Host should be installed in the central position of the guard area to receive the signals from
detectors best. Keep away from large mental objects or appliances with high frequency
interference, meanwhile; avoid the reinforced concrete walls and fire doors barriers etc.
3.3 Disarm
Disarm refers to host panel stops the alarm or make the alarm system in a non-alert state. After
disarming, when detectors are triggered, but host doesn’t alarm (except the detectors of
emergency zones and the emergency button on remote control). After disarming operation, it
displays and locks “Disarm” icon.
Remote Control operation: press key [Disarm].
Keyboard operation: press key [Disarm].
3.7 Accessories
Picture 3-2
Host will exit automatically after 10s, and user can press any key to end recording during
recording process.
3. 12 WIFI Configuration
In the main page, press [Up / Down] to [WIFI configuration], then press [OK] button
or press the number 7 to enter WIFI configuration page, as shownFigure-27, when
configuring WIFI, Please press keypad number 1, if you want to cancel all users,
please press keypad number 2, as shown Figure-28.
Figure-27 Figure-28
3.13 Check Records
On the main page, press [Up / Down] to [Check Records], then press [OK] button or number 7
into checking records page, as shown Figure-29, Figure-30, Figure-31.
Figure-29 Figure-30 Figure-31
On [Check Records] page, press [OK] key to enter [Alarm Records], as shown in picture 3-28. Press
key [UP/DOWN] to check alarm records. At most 102 records can be saved, and each record
includes information like record number, alarm date, time, zones etc.
On [Check Records] page, press [UP/DOWN] key to move the cursor to [ Arm/Disarm Records]
and press [OK] or number 2 to enter [ Arm/Disarm Records] page, as shown in picture 3-29.
Pres[UP/DOWN]to check Arm/Disarm records. As most 72 records can be saved, and each record
includes information like record number, Arm/Disarm date, time and mode, etc.
In addition to set parameter through host menu, SMS or Faction Message can also set host
parameters. The form is as below:【System Password】+【Command Number】+ parameter
1+parameter 2+parameter 3+parameter 4. All commands begin with system password, and 1234
is system’s initial password. Users can change system password and since then, users should use
the modified password, or host will not response to the commands.
NO. Name Comma Parameter1 Para. 2 Para. 3 Para. 4 Example
nd No.
1 Disarm 0 # 12340#
Disarm
2 Arm 1 # 12341#
Arm
3 STAY 2 12342#
STAY
4 Relay ON 3 12344#
Relay ON
6-Doorbell Zone
7-Welcome Zone
8-Help The
Senior Zone
22 Check 60 01~99; 12346001#
Zone 01-99 Zone Check 01 Zone Attribute
Attributes
23 Set 64 01~99; 100-Medical # 12346438151#
Network 01-99 Zone treatment Set Zone 38 as Gas zone
Feature 110-Fire
Code 121—Robbery
122-Silence Rob
130-Burglar
131-Surrounding
151-Gas
After hosting account registration, the Home screen will display the name of the account, click
the account name to enter the user interface; sliding to the left, you can enter the setup interface
and other interfaces. IOS phone system, click icon[message of APP], click [Send], the alarm host
SIM card receive a text message, the host will "drop" a sound and automatically respond text
messages to your phone, the setting is successful.
Wi-Fi 模式
Sign up hosting accounts and login, you can enter the device page, Devices page has an online
Offline devices: The network equipment configuration is successful, and binds with the mobile
phone account before, but this time did not connect to the Internet;
Unbound equipment: The network equipment configuration was successful but the mobile
Online Equipment: The network equipment configuration is successful, and successfully binds
After W18 enter WIFI configuration page, press 1 (Note: W18 Before not configured successfully
[APP] into the Device List page, click the [+] icon, select the [I want to configure] button, and then
enter the WiFi password, click on 【next】button to enter the start configuration page. (Note: The
network must be configured in the same WIFI)
APP successfully configured before automatically jump the device list page, in the unbound
device filed show a device, click it will automatically jump online, click into the device control
page willimmediately enter the device password (device password factory as follows: 1234),
Host Operation
Enter APP operation page with 4 set key [alarm call], [message number], [alarm recording],
Click Actions page alarm call into the phone settings, click [ ]and alarm telephone numbers
can be added, if you want to delete it, press and hold the number you want to delete, then click
[ ] You can deletenumbers. (Note: You can set up six groups SMS numbers)
SMS numbers set
Click operation to enter the page number of the SMS message number setting, click [ ]you
can add alarm SMS numbers, if you want to delete it, press and hold the message you want to
delete it, click [ ], you can delete the appropriate settings SMS numbers. (Note: You can set up
six groups SMS numbers)
alarm record
Click the alarm recording operation page, you can check the host alarm records (Note: APP is up
for the latest 15 alarm records)
Monitor
Click Actions page [ ] you can add cameras to monitor. Make network configuration
first, after the configuration will show [find a new device], click into the add pages, modify
camera name and input Webcam password (password is 123), click it to enter the monitoring
screen.
Edit
Device Name: Click [Device Name], enter a new name, and press OK to save;
Equipment Password: The default device password is 1234, you can click it and enter the new
password, press [Enter] to save; even if that someone knows your WIFI password, they cannot
control your device.
Voice alarm switch: open voice alarm, host alarm, APP alarm voice prompts.
Delete Device: Click [Remove Device] key, you can off binding status of the device. After you
remove the device, you need to re-bind again.
In the [zone setup] page to modify the name of W18's 99 zones, check alarm records in APP
easily.
System Settings
In APP operating page, click[ ] to enter the [System Settings] page. There are [Device
Management], [Account Management], [help], [About Us], [switch to GSM] and [Back to device
list] 6 function keys:
Device Manager: Click [Device Manager] enter the device management page or the drop-down
menu, you can choose to use a different W18 alarm host.
User Management: Click [User Management], you can change the user password; click on the
logout page [cancel] key, you can log off, when you open the APP again, you need to re-enter
again.
Help: Click [Help],let the user to understand the control panel W18 common actions and FAQ.
About: Click on [about us], W18 can check the software version of the control panel and
introduction of the Company.
Switch to GSM: Click [switch to GSM],you can set APP. (Note: In the Device List page, click [ ]
you can switch to GSM)
Note: both monitoring and speaking time are 20 seconds. Press [3] key to continue monitoring.
Press [5] to continue speaking within 20s.
User can use any phone to call the phone number of the phone card on the host. After a ringing
cycle the host will automatically get through. After hearing prompt, enter password (host
factory default is "1234", there would be a prompt when imputing the wrong password. The
system will automatically hang up if the third time is still incorrect). You will hear a prompt when
password is correct. Then, press following keys to control the corresponding functions:
Note: both monitoring and speaking time are 20 seconds. Press [3] key to continue monitoring.
Press [5] to continue speaking within 20s.
Normal STAY Zone Intelligent Help the Senior Doorbell Welcome Emergency
Zone Zone Zone Zone Zone Zone
01-59 Zone 60-79 Zone 80-89 Zone 90 Zone 91 Zone 92 Zone 93-99 Zone
The door contact should be installed on the movable door or windows. Firstly, make the
installation position clean. Take out wireless door sensor, and then stick the double faced
adhesive tape on the bottom. The installation should note the following items:
1.The door sensor part A (transmitter) and part B (magnet) should be installed separately, that is,
A on fixed door and B on movable door.
2. A and B should be in the same vertical line and the distance between A and B should not be
greater than 1 cm.
3. After the installation, the indicator light flashes for 1s as the door open, that means the door
sensor is installed successfully.
4. The indicator lighting for 1 second means alarm. The indicator in constant light is a suggestion
of low power.
5. A, B can also be reinforced by screws, (A: remove the bottom cover, strengthen the screw and
then cover the bottom again; B can be directly fixed by the screw.)
Before use, make sure the power switch of PIR motion sensors is on. Installation height is about
2.2 meters above ground and it should be installed in the corner of the room to get the best
detection range. At the same time, it should form a certain angle with the walking line (90 degree
angle is best for detection).
Installation:
Talk out the supplied bracket; insert the bracket to the slot. Take out the pedestal and fix it with
two screws on the wall. Press the PIR with bracket into the center hole of the pedestal. And then
adjust the best angle of detector. (This method is suitable for project installation)
Attention:
1. The detector should not face the outside of window directly.
2. There should be no any big objects for obstruction within coverage of detection.
3. There should be no two infrared detectors in the same space as they will possibly intervene
with each other.
4. Avoid facing window, cooling or warming machine, stoves, or other appliances that cause
temperature changing sharply, which may cause false alarm.
5. Infrared detector should be used indoor only.
Chapter Nine Troubleshooting