Sunteți pe pagina 1din 44

Fibre Unit Selection Guide

Choose from the largest selection of fibre optic sensors in the industry!

FU-E40 40 mm AREA BEAM FU-L INTEGRATED BRACKET FIBRES


Please contact us
if you have any questions.
Tell the operator you want to
find out more about Fibre Units.
Specialists are available
to take your call.

Easy step-by-step fibre search

Model Page Model Page Model Page Model Page


FU- 10 P.19 FU- 38S P.32 FU- 63 FU- 82C
P.29
11 38V P.25, 32 63T 83C
P.22 P.17
12 4F 63Z 84C P.28
P.15
13 4FZ 65X 85A
P.23
15 40 66 P.11 85H P.29
P.24
16 40G 66TZ P.10 85Z
16Z P.24 40S P.32 66Z 86A
18 41TZ 67 86H P.28
P.7 P.11
18M P.24, 32 42TZ 67G 86Z
20 P.21 43 P.17 67MG 87
P.29
21X P.11 44TZ P.7 67MTG 87K
22X P.15,17 45X 67TG P.10 88
P.15, 17 P.28
2303 P.11 46 67TZ 88K
23X P.15 47TZ P.7 67V P.11 91
P.27
24X 48 68 92
P.11 P.15, 26 P.26
25 49X 69X 93
2540 P.19 5F 7F 93Z
P.14
31 P.17 5FZ 71 P.9 95
32 P.16 50 P.24 71Z 95HA P.30
33 P.17 51TZ 73 95S
34 P.16 52TZ 75F P.16 95W
P.6
35FA 53TZ 76F 95Z
P.11
35FZ 54TZ 77 96 P.27
35TG 55 P.14 77G P.9 E40 P.22
P.10
35TZ 56 P.14, 16 77MG L50Z
37 57TE P.26 77MTG L51Z
P.25
38 57TZ P.6 77TG P.8 L52Z P.4
38H 58 P.14 77TZ L53Z
P.29, 33
38K 59 P.14, 26 77V L54Z
38L P.32 6F 78 P.9 L41Z P.5
38LK P.29, 33 61 P.11 79
38R P.32 61Z 81C P.29

Dimensions for each fibre unit can be found starting from P.34 of this catalogue.

2
Selecting a Fibre Sensor
Follow the steps below to select the fibre sensor that suits your particular needs.

1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Pages 4 to 33.  Listed on the back


(Dimensions diagram on of this catalogue.
pages 34 to 43)

STEP 1 Select a sensor type

Select from a variety of fibres specifically designed


Mounting Configurations for easy installation.

I ntegrated Bracket Flat


Bracket Threaded and
Fibres Hex-shaped Fibres Cylinder Sleeve

 P.4  P.6  P.8  P.14  P.16

Sensor is integrated Flat pack fibres Hex shape allows Secured using a set Tip is a thin sleeve.
into a metal bracket. provide space saving. easy mounting onto a screw. Allows space-
bracket. saving installation.

Beam Configurations Select from a variety of beam styles and shapes.

SmallSpot Retro- NarrowField/ Definite-


Reflective Area reflective High-Power reflective
 P.18  P.22  P.23  P.24  P.25

Ideal for small object Reliable detection of  xcellent for


E Built-in lensing  etection within a
D
detection. vibrating targets. transparent target tightens beam angles fixed distance.
detection. to provide for long
distance detection.

Application-specific Select from a variety of fibres to suit your application needs.

Oil/Chemical Liquid
Crystals/
High-flex Resistant Heat Resistant Liquid-level Semiconductors
 P.26  P.27  P.28  P.30  P.32

Ideal for use where Sensor is encased in Ideal for use under high Pipe attachment and Sensors for alignment
fibre optic movement a PTFE case. temperatures. Withstands direct contact liquid level and mapping.
is required. up to 350°C. sensors are available.

3
STEP 2 Select a specific sensor

The bracket and sensor are


Integrated Bracket integrated, which eliminates the
need for troublesome assembly.

Until now, installation Bracket and sensor are


required too many integrated, making
troublesome parts. installation quick and simple.

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres. Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Beam Optical Appearance bend (Standard detectable Dimensions
Detecting Ambient radius MEGA object*2
emitting axis Other power modes target to be Weight
method direction height temperature FINE detected)

2 m Free-cut (ø2.2)
-40 to +50°C
ULTRA : 3600 (3600)
13 3600 (3600) SUPER : 3600 (3600) FU-L50Z
ø3.5
Approx. 30 g P.41
TURBO : 3600 (3000)
1900 (1500)
14 20 HSP : 1400 (900)
2-ø3.4
10
2 m Free-cut (ø2.2)
-40 to +50°C
12.2 FU-L51Z
Approx. 30 g
12.2 17
2-ø3.4
Top
2 m Free-cut (ø2.2)
-40 to +50°C ULTRA : 1170 (990)
Thrubeam 17 R2 1530 (1170) SUPER : 680 (540) FU-L52Z
15 ToughFlex
TURBO : 540 (420)
ø0.005
Approx. 30 g P.41
270 (210)
12.2 17 HSP : 180 (125)
2-ø3.4
ø1.13
2 m Free-cut (ø2.2)
-40 to +50°C
22
20
FU-L53Z
Approx. 30 g

12.2 17
2-ø3.4

2 m Free-cut (ø2.2)
-40 to +50°C ULTRA : 1100 (640)
1300 (1000) SUPER : 620 (430) FU-L54Z
Side 10
2-ø3.4 Approx. 30 g P.41
TURBO : 500 (350)
250 (200)
12.8 HSP : 160 (90)
17 12.8

*1 When using the FS-V30.


*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Smaller types can be found on P.6.

4
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm Integrated


Bracket
Type Fibre unit length Detecting distance*1
(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Beam Optical Appearance bend detectable Dimensions
Detecting Ambient radius MEGA object*2
emitting axis Other power modes Weight Flat Bracket
method direction height temperature FINE
2 m Free-cut (ø2.2)
-40 to +50°C
ULTRA : 400 (320)
Threaded/
R2
500 (400) SUPER : 220 (180) FU-L41Z Hex-shaped
Reflective Top 10 13
2-ø3.4 ToughFlex ø0.005 Approx. 25 g
P.41
TURBO : 170 (130)
85 (65)
HSP : 50 (36)
14 17
Cylinder
* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Sleeve
Smaller types can be found on P.7.

Small Spot

Area

What our customers are saying. . .  etro-


R
reflective

Installation used to be so hard when there were Comparing the old and new sensor styles, it is  arrow Field/
N
High-Power
a large number of sensors. This is much easier. easy to see that the new fibres are much smaller.
This helps to make designs more compact.  efinite-
D
reflective
The optical axis height is easy to understand, Why didn’t we have something like this before?
which simplifies design. High-flex

With the built-in lens, there is no more worry


that the lens might come off.  il/Chemical
O
Resistant

 eat
H
Resistant

Liquid-level

L iquid Crystals/
Semiconductors
Conventional Conventional Conventional FU-L

No more worries about bracket design, bracket


and sensor assembly, or loose brackets.
Integrated designs reduce space requirements.

5
STEP 2 Select a specific sensor

Can be installed
Flat Bracket Fibres where little space is available.

Flat bracket
fibre installation
example

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Beam Appearance bend (Standard detectable Dimensions
Detecting Ambient radius MEGA object*2
emitting Other power modes target to be Weight
method direction temperature FINE detected)

1 m Free-cut (ø1.0)
-40 to +50°C 10
ULTRA : 300 (230)
2-ø2.1 380 (280) SUPER : 180 (150) FU-51TZ
ø0.5 Approx. 5 g P.37
TURBO : 150 (120)
10 75 (60)
HSP : 45 (25)
Thickness: 3
Top
2 m Free-cut (ø1.3) 14
-40 to +50°C ULTRA : 1100 (850)
2-ø3.2 1300 (1000) SUPER : 620 (500) FU-52TZ
ø1 Approx. 15 g P.37
TURBO : 500 (400)
14 250 (200)
HSP : 160 (100)
Thickness: 3.5
1 m Free-cut (ø1.0)
-40 to +50°C
ULTRA : 250 (200)
10.5
R2 330 (250) SUPER : 150 (120) FU-57TZ
Thrubeam Side 2-ø2.1 ToughFlex ø0.005 Approx. 5 g P.38
TURBO : 110 (90)
6 55 (45)
HSP : 35 (25)
Thickness: 2.5
ø0.5
1 m Free-cut (ø1.0)
7 ULTRA : 200 (150)
13 2-ø2.1
250 (200) SUPER : 130 (100) FU-53TZ
Approx. 10 g
TURBO : 100 (80)
50 (40)
HSP : 40 (25)
-40 to +50°C Thickness: 2
Flat P.37
2 m Free-cut (ø2.2)
7 ULTRA : 1100 (850)
15 2-M3
1300 (1000) SUPER : 620 (500) FU-54TZ
ø1 Approx. 25 g
TURBO : 500 (400)
250 (200)
HSP : 160 (100)
-40 to +50°C Thickness: 4

*1 When using the FS-V30.


*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

FU-51TZ/52TZ also can be used as side-view fibres. FU-51TZ FU-52TZ

6
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Beam Appearance bend detectable Dimensions
Detecting radius MEGA object*2
method
emitting Ambient Other power modes Weight Flat Bracket
direction temperature FINE
1 m Free-cut (ø1.0 x 2)
-40 to +50°C ULTRA : 1 to 75 (1 to 60) Threaded/
2-ø2.1 1 to 90 (1 to 75) SUPER : 1 to 45 (1 to 37) FU-44TZ Hex-shaped
Top 6.5 Approx. 3 g
TURBO : 1 to 37 (1 to 30)
1 to 25 (1 to 20)
8 HSP : 1 to 9 (1 to 6)
Thickness: 2 Cylinder
P.37
1 m Free-cut (ø1.0 x 2)
-40 to +50°C ULTRA : 1 to 75 (1 to 60)
10.5 1 to 90 (1 to 75) SUPER : 1 to 45 (1 to 37) FU-47TZ Sleeve
Side Approx. 4 g
2-ø2.1 TURBO : 1 to 37 (1 to 30)
1 to 25 (1 to 20)
7.2 HSP : 1 to 12 (1 to 8)
Thickness: 2.5
Reflective R2 ø0.005
ToughFlex gold wire Small Spot
1 m Free-cut (ø1.0)
-40 to +50°C ULTRA : 2 to 50 (2 to 40)
2 to 60 (2 to 50) SUPER : 2 to 25 (2 to 20) FU-41TZ
2-ø2.1 TURBO : 2 to 20 (2 to 16) Approx. 5 g Area
2 to 10 (2 to 8)
13 HSP : 2 to 6 (2 to 4)
7 Thickness: 2
Flat
2 m Free-cut (ø2.2 x 2)
P.36  etro-
R
-40 to +50°C
ULTRA : 1 to 250 (1 to 200)
reflective
1 to 320 (1 to 250) SUPER : 1 to 120 (1 to 100) FU-42TZ
Approx. 24 g
2-ø3.2 1 to 37 (1 to 30)
TURBO : 1 to 75 (1 to 60)  arrow Field/
N
20 HSP : 1 to 30 (1 to 25) High-Power
7 Thickness: 4

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.  efinite-
D
reflective
Thin, small spot can be found on P.25.
High-flex

Example Installation Applications  il/Chemical


O
Resistant

 eat
H
Resistant

Liquid-level

L iquid Crystals/
Semiconductors

Cover page alignment Circuit board detection Thin work via hole detection  etecting presence/absence
D
of film

 etal casing eliminates concern about damaged sensors.


M
The sensor and case form a flat surface, so there are no
openings where dust and other foreign matter can form.

7
STEP 2 Select a specific sensor

Conventional threaded fibres


Threaded and Hex-shaped Fibres mount onto brackets like the one
shown below.

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting Ambient radius MEGA Other power modes object*2
Shape Size target to be Weight
method temperature FINE detected)
2 m Free-cut (ø2.2)
-40 to +50°C M4
14.4 R2 FU-77TZ
ToughFlex Approx. 43 g
P.39

1 m cut not allowed. ULTRA : 1100 (880)


-40 to +50°C M4 1400 (1100) SUPER : 650 (500)
Hex- Thrubeam M4 15 R10 ø1.13 ø0.005
FU-77TG
shaped Stainless Steel TURBO : 500 (400) P.39
250 (200) Approx. 43 g
HSP : 170 (110)

1 m cut not allowed.


-40 to +50°C
18 M4 R20 FU-77MTG
Stainless Steel Approx. 100 g
P.39
Lens attachment P.12
*1 When using the FS-V30.
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

See P.12 for specifications when a thrubeam lens is attached.

8
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

RED indicates thrubeam fibres. Integrated


Unit: mm
Bracket
Type Fibre unit length Detecting distance *1
Optical axis
(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting radius MEGA object*2
Shape method Size Ambient Other power modes target to be Weight Flat Bracket
temperature FINE detected)
1 m Free-cut (ø1.0) ULTRA : 420 (330)
-40 to +70°C 500 (380)

M3
R4
High-flex
SUPER : 270 (200)
ø0.7 FU-79 P.40
Threaded/
10
125 (100) TURBO : 220 (170) Approx. 6 g Hex-shaped
M3 Lens attachment P.12 HSP : 70 (35)

2 m Free-cut (ø2.2)
-40 to +50°C Cylinder
R0.5 FU-77V
ToughFlex Approx. 25 g P.39

M4
14
Sleeve
R2 FU-77
ToughFlex
Approx. 21g P.39
ULTRA : 1300 (1100)
1700 (1300) SUPER : 750 (600) ø1.13 Small Spot
1 m cut not allowed. TURBO : 600 (460)
-40 to +50°C 300 (230)
HSP : 200 (140)
R10 FU-77G P.39
M4 22 Stainless Steel
Approx. 39g Area

M4
1 m cut not allowed.
Threaded Thrubeam -40 to +50°C  etro-
R
R20 ø0.005 FU-77MG P.39 reflective
M4 Stainless Steel Approx. 100 g
27
Lens attachment P.12
 arrow Field/
N
2 m Free-cut (ø2.2)
-40 to +70°C ULTRA : 1600 (1100) High-Power
2300 (1400)
R25 SUPER : 950 (800) FU-7F P.39
M4 15 400 (320) TURBO : 800 (600) Approx. 21 g  efinite-
D
Lens attachment P.12 HSP : 220 (150)
reflective
ø1
2 m Free-cut (ø1.3)
-40 to +70°C ULTRA : 800 (600)
1100 (750)
R4
SUPER : 460 (370) FU-78 P.39
M4 15 190 (150) TURBO : 370 (300) Approx. 9 g High-flex
HSP : 130 (75)
Lens attachment P.12
2 m Free-cut (ø2.2) ULTRA : 1900 (1300)  il/Chemical
O
FU-71Z: -40 to +50°C
FU-71: -40 to +70°C
R2
2400 (1700) SUPER : 1100 (900) FU-71Z P.39 Resistant
ToughFlex TURBO : 900 (700) Approx. 25 g
450 (350)
HSP : 270 (160)
M6 ø1.5  eat
H
M6 ULTRA : 2000 (1600) Resistant
16 2600 (1900)
R25
SUPER : 1350 (1000) FU-71 P.39
TURBO : 1000 (850) Approx. 25 g
550 (450)
HSP : 330 (200) Liquid-level
*1 When using the FS-V30.
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
L iquid Crystals/
Semiconductors
See P.12 for specifications when a thrubeam lens is attached.

9
STEP 2 Select a sensor type

Threaded and Hex-shaped Fibres

(Continued)

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting Detecting Ambient radius MEGA object*2
Shape Size Other power modes Weight
method Arrangement temperature FINE
1 m Free-cut 18.5 180 (140) ULTRA : 140 (110)
M3 Coaxial
(ø1.3 x 2) R2 SUPER : 75 (60) FU-35TZ P.35
ToughFlex 30 (23) TURBO : 55 (42) Approx. 7 g
-40 to +50°C M3 Lens attachment P.18 HSP : 20 (16)

2 m Free-cut 13.5 ULTRA : 280 (230)


(ø1.3 x 2) R2 350 (280) SUPER : 150 (120) FU-66TZ
M4 ToughFlex TURBO : 100 (80) Approx. 10 g
P.38
50 (40)
-40 to +50°C M4 HSP : 35 (28)

2 m Free-cut 15.8
(ø2.2 x 2)
R2 FU-67TZ P.39
Hex- ToughFlex ø0.005 Approx. 32 g
Reflective
shaped -40 to +50°C M6 gold wire
Parallel
1 m cut not allowed. 17 ULTRA : 400 (320)
R10 500 (400) SUPER : 200 (160) FU-67TG
Stainless
Steel 75 (60) TURBO : 150 (120) Approx. 32 g
P.39
-40 to +50°C M6 HSP : 45 (33)
M6
1 m cut not allowed. 20.5
R25 FU-67MTG
Stainless
Steel Approx. 80 g
P.38
-40 to +50°C M6

1 m cut not allowed. 22.5 180 (140) ULTRA : 140 (110)


R10 SUPER : 75 (60) FU-35TG
Coaxial Stainless
Steel 30 (23) TURBO : 55 (42) Approx. 32 g
P.35
-40 to +50°C M6 Lens attachment P.18 HSP : 20 (16)

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

See P.18 to 20 for specifications when a reflective lens is attached.

10
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting Detecting radius MEGA object*2
Shape
method
Size
Arrangement
Ambient Other power modes Weight Flat Bracket
temperature FINE
1 m Free-cut
(ø1.3 x 2) 17
R2 FU-35FZ P.35 Threaded/
ToughFlex Approx. 6 g
-40 to +50°C M3 200 (160)
ULTRA : 160 (130) Hex-shaped
SUPER : 80 (65)
1 m cut not allowed. 18 32 (25) TURBO : 60 (45)
HSP : 22 (17) FU-2303
R10 Approx. 15 g P.35 Cylinder
-40 to +50°C M3 Lens attachment P.16
1 m Free-cut ULTRA : 270 (220)
23 340 (270)
M3 Coaxial
(ø1.3 x 2) SUPER : 140 (110) FU-35FA
45 (35) TURBO : 90 (70) Approx. 6 g P.35 Sleeve
-40 to +70°C M3 Lens attachment P.16 HSP : 30 (25)
R25
50 cm cut not allowed. 90 (70) ULTRA : 70 (56)
FU-21X: -40 to +70°C SUPER : 35 (28) FU-21X
FU-24X: -40 to +50°C 15 (12) TURBO : 25 (20) Approx. 4 g P.34 Small Spot
15 Lens attachment P.16 HSP : 10 (7)

55 (45) ULTRA : 45 (36)


M3 SUPER : 22 (18) FU-24X Area
R10 8 (7) TURBO : 15 (12) Approx. 4 g P.35
Lens attachment P.16 HSP : 6 (4)

2 m Free-cut ULTRA : 320 (260)


(ø1.3 x 2) R2 400 (320) SUPER : 160 (130) FU-66Z  etro-
R
FU-66Z: -40 to +50°C ToughFlex TURBO : 120 (90) Approx. 10 g P.38 reflective
60 (45)
FU-66: -40 to +70°C HSP : 40 (30)
M4 Parallel 15
ULTRA : 520 (430)
700 (530) SUPER : 350 (250) ø0.005 FU-66  arrow Field/
N
R25 TURBO : 230 (180) gold wire Approx. 10 g P.38 High-Power
M4 125 (100)
HSP : 80 (55)
Threaded Reflective
2 m Free-cut 16 ULTRA : 400 (320)  efinite-
D
(ø2.2 x 2)
R0.5 500 (400) SUPER : 220 (180) FU-67V reflective
ToughFlex
85 (65) TURBO : 170 (130) Approx. 25 g P.38
-40 to +50°C M6 HSP : 50 (36)

2 m Free-cut 17 ULTRA : 550 (450)


(ø2.2 x 2) 680 (550) SUPER : 370 (280) FU-61Z High-flex
TURBO : 250 (200) Approx. 22 g P.38
125 (100)
-40 to +50°C M6 R2 HSP : 80 (60)
ToughFlex
2 m Free-cut 16  il/Chemical
O
(ø2.2 x 2)
FU-67 Resistant
Approx. 21 g P.38
-40 to +50°C M6

1 m cut not allowed. 29 ULTRA : 400 (320)  eat


H
Parallel
R25
Stainless
500 (400) SUPER : 220 (180) FU-67MG Resistant
Steel 85 (65)
TURBO : 170 (130) Approx. 70 g P.38
M6 -40 to +50°C M6 HSP : 50 (36)

1 m cut not 17 Liquid-level


allowed. R10 FU-67G
Stainless
Steel Approx. 29 g P.38
-40 to +50°C M6
L iquid Crystals/
2 m Free-cut ULTRA : 900 (600)
(ø2.2 x 2)
17
950 (750) SUPER : 500 (400) FU-61 Semiconductors
TURBO : 360 (280) Approx. 21 g P.38
200 (150)
-40 to +70°C M6 HSP : 120 (80)
2 m Free-cut 17 ULTRA : 520 (430)
(ø2.2 x 2)
R25
700 (530) SUPER : 350 (250) FU-6F
TURBO : 230 (180) Approx. 21 g P.38
125 (100)
-40 to +70°C M6 HSP : 80 (55)

2 m Free-cut 17 ULTRA : 520 (430)


(ø2.2 x 2) 560 (470) SUPER : 300 (240) FU-25
Coaxial TURBO : 200 (160) Approx. 18 g P.35
-40 to +70°C 100 (80)
M6 HSP : 70 (50)

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

See P.18 to 20 for specifications when a reflective lens is attached.

11
STEP 2 Select a specific sensor

F-4 F-2 F-5 F-1

Detecting Distance
Using Thrubeam Lenses
Unit: mm
Detecting distance*1
Ambient Temperature Model Each detecting distance in parentheses shows the data when the S-APC function is ON.
Type Dimensions Applicable Fibre
Shape Weight MEGA ULTRA SUPER TURBO FINE HSP

Heat Resistance: 70°C 3200 1900


FU-77TZ/77V/77
(2500) (1400)

Tip: ø4.3 3600 3600 2100


Ultra-long FU-7F (3600) (3000) (1500)
detecting distance F-4
Approx. 1 g P.42
Aperture Angle:
2500 1500
Approx. 8° FU-78
9.5 (2000) (1100)

FU-77G/77MG/ 1800 1800


77TG/77MTG (1800) (1400)

Heat Resistance: 300°C FU-77TZ/77V/77/ 3600 3600 1900 1400


84C/88K (3600) (3000) (1500) (900)

3600 2300 1500


FU-7F/86A (3600)
Tip: ø4 (1800) (1000)

Long Distance F-2 3600 3600 2000 1300


Approx. 2 g P.42 FU-86Z (3600)
Aperture Angle: (3000) (1600) (650)
Approx. 15°
7.9
3600 3600 3000 1500 1100
FU-78
(3600) (3000) (2400) (1200) (800)

FU-77G/77MG/ 1800 1800 1400


77TG/77MTG (1800) (1500) (900)

Heat Resistance: 105°C 2300 1500


FU-77V/77
(1800) (1000)

3600 1800
Fixing Nut FU-7F/86A
(2400) (1200)
3600
(3600)
Side-view with F-5 2500 1600
mounting hole Approx. 10 g P.42 FU-86Z
(2000) (800)
5.6
9.3
16.7 2300 1300
FU-78
(1800) (900)

1800 1500
FU-77G
(1800) (1000)

Heat Resistance: 70°C*2 FU-77V/77/ 1800 1400 850 700 400 300
77G/77MG (1400) (1100) (700) (550) (300) (200)

Tip: ø4 2500 2000 1300 1000 500 320


FU-7F/86A
(2000) (1600) (1000) (800) (400) (220)
F-1
Side-view Approx. 2 g P.42
1900 1500 950 750 400 250
FU-86Z
9.5 (1500) (1200) (750) (600) (300) (130)

1400 1100 700 550 300 200


FU-78/84C/88K
(1100) (900) (550) (450) (250) (140)

* 1 When using the FS-V30 Series. The maximum sensing distance of 3600 mm is possible because the fibre length on one side is 2 m.
*2 When using the F-1 at a temperature of 70°C or more, specify the “Heat-resistant F-1”.

12
1 2 3
Select a Select a Select an
general
sensor specific amplifier
type sensor

Integrated
Hex-shaped and Conventional threaded fibres Bracket

Using the hex-shaped fibre as shown below allows for a neater cable configuration. Flat Bracket
This avoids breakage problems caused by the cable being pulled.
Threaded/
Hex-shaped
Threaded Type Hex-shaped Type  ith the hex-shaped
W
fibre, one end is secured
with a nut, so installation Cylinder
is simpler.

Sleeve

Small Spot

Area

 etro-
R
Fibre Cable Type reflective

 arrow Field/
N
Cables are divided broadly into three. The ToughFlex is a cable that reduces problems caused by High-Power
cable bending. It is very versatile and is the choice for general-purpose applications.
 efinite-
D
reflective
ToughFlex Stainless Steel Standard
ToughFlex fibres use fine strands that are
High-flex
bundled into a cable. This provides a high level of
bendability and strain relief.
 il/Chemical
O
Bend radius Bend radius Conventional fibre Resistant
of 2 mm of 0.5 mm
Stainless steel braided cable is used in situations where the  eat
H
fibre could be subjected to impacts. Resistant
Tight bending
causes a break.
Liquid-level
Stainless steel braided cable is recommended in
areas where human traffic passes nearby. ToughFlex fibre
217-core fibre 613-core fibre
L iquid Crystals/
Note: Use High-flex type cable (P.26) in locations where there is the chance Semiconductors
that a cable can move.

No breaking, even
when subjected
to a tight bend
radius.

Parallel (Standard) and Coaxial Fibres

Type Characteristics

Parallel Transmitter and receiver are routed side-by-side in parallel reflective


(Standard) fibre optic sensors.

Transmitter light is located in the centre, while Reciever light is around


Coaxial the periphery. This cable has outstanding short-distancec
haracteristics. Focusing lenses can be attached to coaxial fibre optics.

13
STEP 2 Select a specific sensor

Suitable for installation in


Cylinder (Set Screw Installation) locations where space is limited.
Installed by drilling a hole and
using a set screw.

Set screw

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting Size Ambient radius MEGA Other power modes object*2
method
target to be Weight
temperature FINE detected)
50 cm cut not allowed.
ULTRA : 130 (100)
-40 to +50°C ø1
ø1.0 6 R10
150 (120) SUPER : 65 (50)
ø0.265 FU-58 P.38
TURBO : 50 (40) Approx. 8 g
32 (25)
HSP : 20 (12)

1 m Free-cut (ø1.0) ULTRA : 420 (330)


ø1.5
-40 to +70°C
ø1.5 R4 500 (380) SUPER : 270 (200)
ø0.7 FU-59 P.38
10 High-flex TURBO : 220 (170) Approx. 3 g
125 (100)
HSP : 70 (35)

50 cm cut not allowed. ø2.5 ULTRA : 20 (16)


-40 to +70°C
25 (20) SUPER : 15 (10)
ø0.125 FU-55 P.37
10 TURBO : 10 (7) Approx. 3 g
5 (4)
HSP : – (–)
Thrubeam ø2.5 R10 ø0.005
50 cm cut not allowed. ø2.5 ULTRA : 20 (16)
-40 to +70°C ø0.3
10
25 (20) SUPER : 15 (10)
ø0.125 FU-56 P.37
5 TURBO : 10 (7) Approx. 3 g
5 (4)
Do not bend sleeve. HSP : – (–)

2 m Free-cut (ø2.2) ULTRA : 1300 (1100)


ø3
-40 to +50°C
R2 1700 (1300) SUPER : 750 (600)
ø1.13 FU-5FZ P.37
14 ToughFlex TURBO : 600 (460) Approx. 19 g
300 (230)
HSP : 200 (140)
ø3
2 m Free-cut (ø2.2) ULTRA : 1600 (1100)
ø3
-40 to +70°C
R25
2300 (1400) SUPER : 950 (800)
ø1 FU-5F P.37
15
TURBO : 800 (600) Approx. 19 g
400 (320)
HSP : 220 (150)

*1 When using the FS-V30.


*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

14
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting Size Ambient radius MEGA Other power modes object*2 Flat Bracket
method Weight
temperature FINE
1 m cut not allowed. ULTRA : 60 (50)
-40 to +70°C
15 R4 75 (60) SUPER : 32 (25) FU-49X P.37
Threaded/
High-flex TURBO : 25 (20) Approx. 3 g Hex-shaped
ø1.5 20 (16)
HSP : 13 (10)
ø1.5
1 m cut not allowed. ULTRA : 12 (10)
-40 to +70°C Cylinder
15
R10
15 (12) SUPER : 8 (7) FU-46 P.37
Do not 3 TURBO : 6 (5) Approx. 2 g
bend sleeve. ø1.5 3 (2)
ø0.5 HSP : 1.6 (1.1)
Sleeve
50 cm cut not allowed. ULTRA : 42 (34)
-40 to +70°C
ø2.5 6
14
R25
48 (40) SUPER : 15 (12) FU-22X P.35
Do not TURBO : 13 (10) Approx. 4 g
bend sleeve.
ø1.77
ø2.5 10 (8)
HSP : 6 (4) Small Spot
2 m Free-cut (ø1.3 x 2)
ULTRA : 320 (260)
FU-4FZ: -40 to +50°C
FU-4F: -40 to +70°C R2
400 (320) SUPER : 160 (130) FU-4FZ P.36 Area
ToughFlex TURBO : 120 (90) Approx. 8 g
60 (45)
HSP : 40 (30)
Reflective 17 ø0.005
gold wire
ULTRA : 520 (430)  etro-
R
ø3 700 (530) SUPER : 350 (250) FU-4F reflective
R25
TURBO : 230 (180) Approx. 8 g
P.36
125 (100)
HSP : 80 (55)
 arrow Field/
N
2 m Free-cut (ø1.0 x 2) ULTRA : 130 (110) High-Power
-40 to +70°C
ø3
15 R4 160 (130) SUPER : 70 (55) FU-48 P.37
High-flex TURBO : 50 (40) Approx. 7 g
35 (28)  efinite-
D
ø3 HSP : 22 (17) reflective
50 cm cut not allowed. ULTRA : 550 (440)
-40 to +70°C
17
R25 680 (550) SUPER : 370 (300) FU-23X P.35
TURBO : 250 (200) Approx. 4 g
High-flex
ø3 125 (100) HSP : 85 (60)

50 cm cut not allowed. ULTRA : 35 (28)  il/Chemical


O
-40 to +70°C
5
15
R4
45 (35) SUPER : 18 (14) FU-45X P.37
Resistant
Do not TURBO : 13 (10) Approx. 4 g
bend sleeve. ø3 8 (6)
ø0.82 HSP : 5 (4)
 eat
H
* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) Resistant
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Liquid-level

Selection Tip 1 Fibre Cable Type


L iquid Crystals/
Semiconductors
 he ToughFlex type is a type that eliminates problems caused by the bending of fibres.
T
The High-Flex fibres are designed for repeated bending like what occurs in applications with frequent
movement.
ToughFlex High-flex Standard

Selection Tip 2 Cylinder Type Installation

Q What size of hole needs to


be drilled for installation?
A The diameter tolerance of the sensor conforms
to JIS [JIS - Japanese Industrial Standards]
intermediate. The tolerance is ±0.1 mm up to
an outside diameter of ø6 mm.
For the ø3 type, for example, this translates
to ø2.9 to ø3.1, so a hole of ø3.2 should be
drilled.

15
STEP 2 Select a specific sensor

No more space problems.


Sleeve Sensors can be located closer to
the target.

Connector pin count

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Beam Appearance bend (Standard detectable Dimensions
Detecting emitting Ambient radius MEGA Other power modes object*2
method
target to be Weight
direction temperature FINE detected)

1 m Free-cut (ø1.3) ø2.5


-40 to +70°C ULTRA : 230 (180)
ø0.82
300 (230) SUPER : 100 (75)
ø0.6 FU-32 P.35
15 TURBO : 75 (60) Approx. 5 g
38 (30)
15 HSP : 25 (15)
Do not bend sleeve.
Side View
2 m Free-cut (ø2.2)
ULTRA : 500 (400)
-40 to +70°C 15
ø3 R25
640 (520) SUPER : 320 (250) FU-34 P.35
65 TURBO : 250 (200) Approx. 17 g
ø1.2 125 (100)
HSP : 90 (50)
Min. bend radius of sleeve: R25
ø1
2 m Free-cut (ø2.2) M4
ULTRA : 1600 (1100)
-40 to +70°C
ø1.65 15 2300 (1400) SUPER : 950 (800) FU-73 P.39
TURBO : 800 (600) Approx. 24 g
67 400 (320)
Min. bend radius HSP : 220 (150)
of sleeve: R10
Thrubeam ø0.005
1 m Free-cut (ø1.0)
M3 ULTRA : 340 (260)
-40 to +70°C ø0.82
15
400 (300) SUPER : 180 (150)
ø0.5 FU-75F P.39
15 TURBO : 150 (120) Approx. 10 g
95 (75)
HSP : 50 (30)
Do not bend sleeve.
Top View
1 m Free-cut (ø1.0) ø3
-40 to +70°C ULTRA : 130 (100)
ø0.4 15
R10
160 (130) SUPER : 65 (50)
ø0.265 FU-76F P.39
TURBO : 50 (40) Approx. 10 g
45 32 (25)
Min. bend radius HSP : 18 (10)
of sleeve: R10
50 cm cut not allowed. ø2.5
-40 to +70°C ULTRA : 20 (16)
ø0.3
10
25 (20) SUPER : 15 (10)
ø0.125 FU-56 P.37
5 TURBO : 10 (7) Approx. 3 g
5 (4)
HSP : – (–)
Do not bend sleeve.

*1 When using the FS-V30.


*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

The long sleeve fibres allow


for some bending.
See the dimensions diagram
for bend ranges.

16
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Beam Appearance bend detectable Dimensions
Detecting emitting Ambient radius MEGA Other power modes object*2 Flat Bracket
method Weight
direction temperature FINE
2 m Free-cut (ø1.0 x 2)
ULTRA : 68 (54)
-40 to +70°C ø2.8 Threaded/
85 (68) SUPER : 34 (27) FU-31 P.35
ø2 R10
TURBO : 25 (20) Approx. 5 g
Hex-shaped
15 17 (13)
15 HSP : 11 (8)
Do not bend sleeve.
Side
1 m Free-cut (ø2.2 x 2) ø4.8 Cylinder
-40 to +70°C ULTRA : 150 (120)

ø2.1 15
R25
180 (150) SUPER : 75 (60) FU-33 P.35
TURBO : 50 (40) Approx. 10 g
25 (20)
65 HSP : 18 (14) Sleeve
Min. bend radius of sleeve: R25

50 cm cut not allowed.


M3 ULTRA : 35 (28)
-40 to +70°C
ø0.82 R4
45 (35) SUPER : 18 (14) FU-65X P.38
Small Spot
15 TURBO : 13 (10) Approx. 5 g
8 (6)
15 HSP : 5 (4)
Do not bend sleeve.

2 m Free-cut (ø1.3 x 2) Area


M4 ULTRA : 110(90)
-40 to +50°C
ø2 15 R2 130 (110) SUPER : 55(45) FU-63Z P.38
ToughFlex TURBO : 43(35) Approx. 10 g
67 25 (20)  etro-
R
HSP : 13(8) reflective
Min. bend radius of sleeve: R10
2 m Free-cut (ø1.3 x 2) M4
-40 to +70°C
 arrow Field/
N
ø1.65 15
FU-63 P.38
Approx. 10 g
High-Power
67 ULTRA : 150 (120)
Reflective Min. bend radius of sleeve: R10 180 (150) SUPER : 85 (70) ø0.005
2 m Free-cut (ø1.3 x 2)
R25
TURBO : 60 (50) gold wire  efinite-
D
-40 to +70°C 37 (30) reflective
ø1.65 HSP : 24 (16)
15 FU-63T P.38
Top Approx. 10 g
67
High-flex
Min. bend radius of sleeve: R10
50 cm cut not allowed.
ø3 ULTRA : 35 (28)
-40 to +70°C
ø0.82
45 (35) SUPER : 18 (14) FU-45X  il/Chemical
O
R4
TURBO : 13 (10) Approx. 4 g
P.37 Resistant
15
5 8 (6)
HSP : 5 (4)
Do not bend sleeve.
 eat
H
2 m Free-cut (ø1.3 x 2)
-40 to +70°C ø4 ULTRA : 150 (120) Resistant
ø1.65
R25
180 (150) SUPER : 85 (70) FU-43 P.37
15 TURBO : 60 (50) Approx. 8 g
22 37 (30)
HSP : 24 (16) Liquid-level
Do not bend sleeve.

1 m cut not allowed.


-40 to +70°C ULTRA : 12 (10)
ø1.5 L iquid Crystals/
R10
15 (12) SUPER : 8 (7) FU-46 P.37
ø0.5
TURBO : 6 (5) Approx. 2 g
Semiconductors
15 3 (2)
3
HSP : 1.6 (1.1)
Do not bend sleeve.

50 cm cut not allowed.


ø2.5 ULTRA : 42 (34)
-40 to +70°C
Coaxial,
narrow
ø1.77
R25
48 (40) SUPER : 15 (12) FU-22X P.35
beam 10° 14 TURBO : 13 (10) Approx. 4 g
6 10 (8)
HSP : 6 (4)
Do not bend sleeve.

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

When determining the smallest detectable object, positioning the sensor


too closely to the object caused the object to disappear making alignment
difficult. With the sleeve type, the sensor itself does not become an
obstruction and alignment is easier.

17
STEP 2 Select a specific sensor

Great for Small Object Detection


Small Spot Reflective Reflective type fibre sensors are great for small
object detecting. Select the sensor according to the
size of the object.

Ask the Expert


Call us for Details on
the FU Series

Small spot sensors come in the three types described below. Select the sensor you
need according to application conditions.
The FU-23X + F-2HA ( P.20) and the FU-20 ( P.21) produce the smallest beam spot of
ø0.1 mm.

Adjustable Beam Spot Fibres P.19


Spot size is easily selectable.
Focal distance is variable, so there is no need to adjust
the distance between the sensor and the target.
8 to 30 mm

10 to 30 mm

ø0.9 to ø0.5 to
Parallel Beam Spot Fibres P.19 ø3.5 mm ø3.0 mm

With a beam spot of approximately 4 mm the spot


radius does not change from 0 to 20 mm.
This is great for applications where distance varies due
to vibration and other factors.
20 mm

Small Spot Fibres


Approx. ø4.0 mm
P.20
This type is available as a ø0.1 mm small spot, long
distance type with integrated lens, or as lens-and-fibre
combination type. ø3.0 mm
Select the type you need according to application
conditions. 5 mm 7 mm
15 mm
35 mm

Approx. Approx. Approx. Approx.


ø0.1 mm ø0.4 mm ø0.5 mm ø1.0 mm

18
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Adjustable Beam Spot Fibres Integrated


Bracket
Built-in Lens Fibre Unit Unit: mm
Fibre unit length
(Diameter) Model Minimum Flat Bracket
Beam spot
Type diameter Focal distance Appearance bend Dimensions
Ambient Weight radius
temperature
2 m Free-cut (ø1.3 x 2) Threaded/
M6 Hex-shaped
-40 to +70°C FU-10 R25 P.34
Approx. 5 g

26.4 to 31.5
Adjustable beam spot ø0.9 to 3.5 10 to 30 Cylinder
M6
FU-2540 R25 P.35
Sleeve
26.4 to 31.5

Lens + Fibre Unit Unit: mm Small Spot


Lens Fibre units

Type Beam spot Minimum Dimensions


diameter Focal distance Appearance
Model bend Appearance
Appearance Model
Weight radius Area
R2
ToughFlex
8.7
FU-35FZ  etro-
R
reflective
5.6
R10
Side-view ø0.5 to 3 8 to 30 F-5HA FU-2303 P.35
adjustable spot
15
 arrow Field/
N
High-Power
R25
Approx. 2 g
FU-35FA
 efinite-
D
reflective

FU-10 FU-10 F-5HA+FU-35FZ


Adjustable beam spot Adjustable range of spot Target width vs. operating range High-flex
diameter (Typical) (Typical)
4 35
Insertion depth 9.4 mm  il/Chemical
O
Detecting distance (mm)

Adjustable beam spot diameter 3.5 30


Spot diameter (mm)

Insertion depth 8.4 mm Resistant


ø0.9 mm 3 25 Insertion depth 7 mm
2.5 20
2  eat
H
15 Resistant
1.5 Adjustable
ø3.5 mm range 10
1
0.5 5
0 Liquid-level
0
0 10 20 30 40 0.5 1 1.5 2 3 5
Distance (mm) Beam spot diameter ø (mm)
L iquid Crystals/
Semiconductors

Parallel Beam Spot Fibres


Lens + Fibre Unit Unit: mm
Detecting distance*1
Lens Fibre unit Each detecting distance in parentheses shows the data when the S-APC function is ON.
Type Beam spot Minimum Dimensions
diameter Appearance MEGA
Model bend Appearance Model Other power modes
Weight radius FINE
R2
ToughFlex
FU-35FZ ULTRA : 38 (30)
38 (30) SUPER : 38 (30)
R10 TURBO : 33 (28)
28 (22)
HSP : 20 (16)
FU-2303
Tip: ø4.3
Approx. ø4 R25 ULTRA : 65 (52)
Parallel beam (within F-3HA 65 (52) SUPER : 65 (52)
the detecting of FU-35FA TURBO : 55 (45) P.35
0 to 20 mm) 45 (38)
9.5 HSP : 35 (25)
Approx. 2 g R2
ToughFlex
FU-35TZ ULTRA : 35 (25)
35 (25) SUPER : 35 (28)
R10 TURBO : 30 (25)
25 (20)
Stainless steel HSP : 18 (14)
FU-35TG

*1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)

19
STEP 2 Select a specific sensor

Small Spot Fibres


Lens + Fibre Unit Unit: mm
Lens Fibre unit

Type Beam spot Focal Minimum


diameter distance Appearance Dimensions
Model bend Appearance Model
Weight radius

R10
Approx. ø0.1 FU-24X P.35

R25
Approx. ø0.2 FU-21X P.34

R2
ToughFlex
FU-35FZ
Tip: ø4.3
F-2HA R10
7 ±2
FU-2303
15.6

Approx. 1 g R25
Approx. ø0.4
FU-35FA

R2
ToughFlex
FU-35TZ

R10
Stainless steel
FU-35TG

P.35
R2
ToughFlex
FU-35FZ

Small spot R10


FU-2303

Tip: ø7.4
F-4HA R2
ToughFlex
Approx. ø0.5 15 ±2 FU-35TZ
27

R10
Approx. 2 g Stainless steel
FU-35TG

R25
FU-35FA

R25
Approx. ø1.0 FU-21X P.34

R2
ToughFlex
FU-35FZ
Tip: ø10.6

F-6HA R10
35 ±3
FU-2303
26

Approx. ø2.0 P.35


Approx. 5 g R2
ToughFlex
FU-35TZ

R25
FU-35FA

20
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Small Beam Spot Integrated


Bracket
Built-in Lens Fibre Unit Unit: mm
Fibre unit length
(Diameter) Model Minimum Flat Bracket
Type Beam spot bend Dimensions
Focal distance Appearance
diameter Ambient radius
Weight
temperature
50 cm cut not allowed. Threaded/
-40 to +70°C Hex-shaped
FU-20
Small spot Approx. ø0.1 5 Tip: ø3 Approx. 2 g
R25 P.34
18
Cylinder
* Cannot be used with the FS-V30 Series HIGH SPEED mode.

Sleeve

Problem 1 Solution
Small Spot
Recommended Type:
Vibration or other FU-10 Adjustable
conditions causes Beam Spot Fibre Area
the lens to come off!
The lens unexpectedly Select a type
 etro-
R
comes off making with a fixed lens! reflective
detecting impossible.
 ince the lens has a screw to
S
secure it to the sensor, there  arrow Field/
N
is no more need to worry High-Power
about the lens coming off
due to vibration.  efinite-
D
Vibration causes the
reflective
lens to come off!

High-flex
Solution
Problem 2 Recommended Type:
 il/Chemical
O
Resistant
FU-2303/35TG+ Lens Coaxial Fibre with Spiral
Broken fibre  eat
H
cable! Select a spiral protected type! Resistant
FU-2303/35TG protects against fibre cable breakage.
 The fibre cable catches Protected by stainless steel, the fibre cable maintains
in the work during Liquid-level
a radius of R10 when bent. Protective braided shield
device assembly or increases strength against pulling, while a flexible spiral
maintenance. shield increases strength against side impact. L iquid Crystals/
Semiconductors
Protective
braided shield

Flexible spiral
shield

Problem 3
Solution
No room to install Recommended Type:
sensors! F-5HA Space Saving Lens + Fibre
I want to use a side-
view spot sensor. Select a side-view lens!
 ow a side-view lens can be used for accurate detection
N
60.6 mm
of small work in locations where previous products were
difficult to install.
8.7 mm Also, since the size of the
spot can be changed by
varying the insertion depth
of the fibre unit, there is no
 equires approximately 1/7
R need to be concerned about
the space of previous products. the distance from the work.

21
STEP 2 Select a specific sensor

Great for applications where there


Area is variance in work movement
position and for detecting multiple
work shapes.

Area detection, thrubeam type Area detection,


FU-E40 reflective type
FU-11
69 mm

40 mm 15 mm
19.5 mm

15 mm

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting Optical Ambient radius MEGA object*2
method axis width Other power modes target to be Weight
temperature FINE detected)
69

ULTRA : 3600 (3600)


19.5 3600 (3600)
40 R2 SUPER : 3600 (3600) FU-E40
40
ToughFlex TURBO : 3600 (3600)
40 x 3 ø0.4
Approx. 30 g
P.41
3000 (2200)
2 m Free-cut HSP : 1400 (800)
( ø2.2 x 2)
Thickness:
-40 to +50°C 5.1
Thrubeam
20

ULTRA : 1400 (1100) ø1.2


1700 (1400)
20
R2 SUPER : 1200 (950) (TURBO) FU-12
10 10 ToughFlex TURBO : 950 (750)
10 x 3 ø0.3
Approx. 23 g
P.34
2 m Free-cut 700 (550) (FINE)
(ø2.2) HSP : 320 (180)
Thickness:
-40 to +50°C 4.2

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting Ambient radius MEGA object*2
method Spot width Other power modes Weight
temperature FINE
2 m Free-cut (ø2.2 x 2)
-40 to +70°C 15 ULTRA : 5 to 160 (5 to 160)
5 to 160 (5 to 160) ø0.005
Reflective 15 SUPER : 5 to 150 (5 to 150)
gold wire FU-11
(at distance 15) R25
TURBO : 5 to 140 (5 to 130) (Parallel) Approx. 19 g
P.34
7 5 to 120 (5 to 90)
HSP : 5 to 70 (5 to 55)
28

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Optional metal slit attachment FU-E40 Applications


Small targets can also OP-84365
FU-E40 FU-11
be detected by limiting
the length and width of 30 mm
the detection area with
the slit attachment.

30 × 0.5 mm

OP-84366

20 mm

Chip movement detection Lead frame detection


20 × 0.5 mm

22
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Retro-reflective is effective for


Retro-reflective detecting transparent objects.
Integrated
Bracket

The beam passes through the


Flat Bracket
(transparent) item twice, so light
loss is relatively greater than with Threaded/
the thrubeam type. Hex-shaped

Cylinder

Sleeve
transparent object

Small Spot

Ask the Expert


Call us for Details on
Area
the FU Series

 etro-
R
reflective
GREEN indicates retro-reflective fibres.
Unit: mm
Fibre unit length Detecting distance*1  arrow Field/
N
Type High-Power
(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Model
Beam Appearance bend Dimensions
Detecting Ambient radius MEGA
emitting Other power modes Weight
method direction temperature FINE  efinite-
D
2 m Free-cut (ø1.0 x 2) reflective
-40 to +50°C ULTRA : 10 to 380 (10 to 300)

R2
10 to 480 (10 to 380) SUPER : 10 to 190 (10 to 150) FU-13
M6
17 ToughFlex TURBO : 10 to 125 (10 to 100) Approx. 8 g P.34 High-flex
10 to 60 (10 to 50)
Reflective tape HSP : – (–)
(accessory)*2
Retro- M6
reflective 2 m Free-cut (ø1.0 x 2)  il/Chemical
O
-40 to +50°C ULTRA : 100 to 2500 (100 to 2000) Resistant
Square 26.9 20.8 100 to 3200 (100 to 2500) SUPER : 100 to 1250 (100 to 1000) FU-15
type
R10
TURBO : 100 to 940 (100 to 750) Approx. 12 g P.34
100 to 630 (100 to 500)
HSP : 100 to 500 (100 to 400)  eat
H
Thickness: Reflector: R-2
12.6 (accessory) Resistant

Liquid-level

Reflector / Reflective Tape Specifications (Optional Parts)


Unit: mm
L iquid Crystals/
R-2 (OP-95388) R-3 (OP-96436) R-5 Reflective tape (OP-96629) Semiconductors

Type Power modes 51.2 x 61 35 x 42 14 x 36 40 x 30

MEGA 10 to 940 (10 to 750) 10 to 770 (10 to 620) 10 to 530 (10 to 430) 10 to 480 (10 to 380)
ULTRA 10 to 750 (10 to 600) 10 to 620 (10 to 500) 10 to 430 (10 to 350) 10 to 380 (10 to 300)
SUPER 10 to 380 (10 to 300) 10 to 320 (10 to 250) 10 to 220 (10 to 170) 10 to 190 (10 to 150)
FU-13 TURBO 10 to 250 (10 to 200) 10 to 200 (10 to 150) 10 to 125 (10 to 100) 10 to 125 (10 to 100)
FINE 10 to 125 (10 to 100) 10 to 100 (10 to 75) 10 to 65 (10 to 50) 10 to 60 (10 to 50)
HSP – – – –
MEGA 100 to 3200 (100 to 2500) 100 to 2200 (100 to 1800) 100 to 1300 (100 to 1100)
ULTRA 100 to 2500 (100 to 2000) 100 to 1800 (100 to 1500) 100 to 1100 (100 to 900)
SUPER 100 to 1250 (100 to 1000) 100 to 1000 (100 to 800) 100 to 750 (100 to 600)
FU-15 *1
TURBO 100 to 940 (100 to 750) 100 to 750 (100 to 600) 100 to 600 (100 to 500)

FINE 100 to 630 (100 to 500) 100 to 500 (100 to 400) 100 to 500 (100 to 400)
HSP 100 to 500 (100 to 400) 100 to 430 (100 to 350) 100 to 430 (100 to 350)

* When using the FS-V30 [Red LED]. The values may vary slightly if APC is enabled.
*1 Reflective tape cannot be used.

 he optics of the FU-15 suppress the effects


T
of refraction and deflection for stable and
easy detection of liquid-filled PET bottles and
other objects that tend to generate refraction.
The enclosure rating of FU-15 also is IP67.

23
STEP 2 Select a specific sensor

Use of a lens suppresses beam


Narrow Field / High-power width and reduces deflection.

FU-16Z FU-40

30 mm to
1500 mm Aperture
Angle: 8°

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Beam Appearance bend (Standard detectable Dimensions
Detecting Aperture Ambient radius MEGA object*2
emitting Other power modes target to be Weight
method angle temperature FINE detected)
direction
2 m Free-cut (ø1.0)
ULTRA : 2500 (2000)
FU-16Z: -40 to +50°C
R2 3200 (2500)
SUPER : 1300 (1000) FU-16Z
FU-16/18: -40 to +70°C ToughFlex Approx. 8 g P.34
630 (500) TURBO : 1000 (800)
HSP : 380 (220)
Approx. 6°
ULTRA : 3600 (3000)
ø4 3600 (3600) SUPER : 2000 (1500) FU-16
TURBO : 1500 (1200)
ø2.5 ø0.1
Approx. 8 g P.34
950 (750)
HSP : 500 (280)
13
Side
17 ULTRA : 2500 (2000)

R10
3200 (2500) SUPER : 1500 (1200) FU-18
Thrubeam Approx. 2°
TURBO : 1200 (1000) Approx. 8 g P.34
800 (650)
HSP : 480 (260)

2 m Free-cut (ø1.0)
ULTRA : 700 (650)
-40 to +70°C 850 (800)
SUPER : 360 (330) FU-18M
Approx. 3° 1.5
TURBO : 300 (280)
ø1 ø0.02
Approx. 6 g P.34
240 (220)
2 20 HSP : 130 (110)

2 m Free-cut (ø1.0) ULTRA : 3600 (3600)


-40 to +50°C
4 R2 3600 (3600) SUPER : 3600 (3600) FU-50
Top Approx. 6°
12 ToughFlex
TURBO : 3600 (3200)
ø2.8 ø0.1
Approx. 8 g P.37
2300 (1800)
3.6 HSP : 1500 (850)

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Beam Appearance bend detectable Dimensions
Detecting Aperture Ambient radius MEGA object*2
emitting Other power modes Weight
method angle temperature FINE
direction
2 m Free-cut (ø2.2 x 2)
-40 to +50°C
Thickness: R2 FU-40
5.2 ToughFlex Approx. 23 g P.36
ULTRA : 30 to 1100 (30 to 850)
ø0.3
21 SUPER : 30 to 400 (30 to 320)
Reflective 30 to 1500 (30 to 1200) copper wire
Top Approx. 8°
1 m cut not allowed. TURBO : 30 to 260 (30 to 220) (Vertical)
-40 to +50°C 30 to 150 (30 to 120) HSP : 30 to 100 (30 to 80)
Thickness: R10 FU-40G
5.2 Stainless Steel Approx. 50 g P.36
21

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) “3600” is assumed as maximum because the fibre cable has a length of 2 m.
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Thrubeam type lens attachment can be found on P.12.

Long-distance, retro-reflective type can be found on P.23.

24
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Definite-reflective reduces the


Definite-reflective (Thin, Small) effect of background, small and thin
Integrated
Bracket

configuration requires less space.


Flat Bracket

Definite-reflective optics strictly minimises the


amount of reflected light, except for that from a Threaded/
fixed distance in the detecting range. Hex-shaped

Cylinder
Light is not
reflected
Detecting
range from the
background. Sleeve

Small Spot

Ask the Expert


Call us for Details on
Area
the FU Series

 etro-
R
reflective
BLUE indicates reflective fibres. Unit: mm
Fibre unit length Detecting distance*1
 arrow Field/
N
Type High-Power
(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
Beam spot Smallest Model
Beam Appearance bend diameter detectable Dimensions
Detecting emitting Ambient radius MEGA Other power modes object*2
method Weight
direction temperature FINE  efinite-
D
2 m Free-cut (ø1.0 x 2) reflective
14.4 Approx.
ULTRA : 3 (3) centre of detecting distance
3 (3) centre of ø4.5
detecting distance SUPER : 3 (3) centre of detecting distance FU-37
Side Approx.
ø3.5 Approx. 6 g P.35
3 (3) centre of TURBO : 3 (3) centre of detecting distance High-flex
19 detecting distance
HSP : 3 (3) centre of detecting distance (At distance of 3)
-40 to +70°C Thickness: 5 ø0.005
2 m Free-cut (ø1.0 x 2) gold wire
-40 to +70°C ULTRA : 6 (6) centre of detecting distance
 il/Chemical
O
12 6 (6) centre of
detecting distance SUPER : 6 (6) centre of detecting distance FU-38 Resistant
Approx. ø1.5
Reflective R10 (At distance of 6) Approx. 5 g P.35
6 (6) centre of TURBO : 6 (6) centre of detecting distance
detecting distance
19 HSP : 6 (6) centre of detecting distance  eat
H
Thickness: 4
Top Resistant
2 m Free-cut (ø1.0 x 2)
-40 to +70°C 12 0 to 4 (0 to 4) ULTRA : 0 to 4 (0 to 4)
SUPER : 0 to 4 (0 to 4) ø0.08 FU-38V
–– copper wire Approx. 5 g P.36 Liquid-level
0 to 4 (0 to 4) TURBO : 0 to 4 (0 to 4)
19 HSP : 2 ±1.4 (2 ±1.4)
Thickness: 4.3
L iquid Crystals/
*1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) Semiconductors
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Longer distance retro-reflective types can be found on P.32.

 oth types are thin to aid installation where space


B
is limited. Since the effects of the background are
minimised, stable detection is possible in complex
environments. The FU-38 is a small spot type, which is
great for small object detecition.

25
STEP 2 Select a specific sensor

Provides higher flexibility than an


High-flex electric wire. R4 models are
resistant to repeated bends.

Cable Flexibility Data


Comparison of bending frequency up to breakage with bending tester
Rough sketch Bending frequency up to
Tested target core wire breakage
ø1 mm
metallic cord 131 times
3-core cable 2200 times
High-flex
1 kg fibre 80000 times or more

[Measuring conditions] Roller diameter: 8 mm (R4 mm) Load: 1 kg

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting Ambient radius MEGA object*2
Size Other power modes target to be Weight
method temperature FINE detected)

1 m Free-cut (ø1.0)
ø1.5
-40 to +70°C
ø1.5 FU-59 P.38
10 Approx. 3 g
ULTRA : 420 (330)
500 (380) SUPER : 270 (200)
1 m Free-cut (ø1.0) TURBO : 220 (170)
125 (100)
-40 to +70°C HSP : 70 (35)
Thrubeam M3
R4
ø0.7 ø0.005
FU-79 P.40
10 High-flex
Approx. 6 g
M3
1 m Free-cut (ø1.0)
ULTRA : 250 (200)
320 (250)
6 x 10.5 x 2.5
SUPER : 140 (110) FU-57TE P.38
TURBO : 100 (80) Approx. 5 g
50 (40)
-40 to +70°C 6 10.5 HSP : 30 (20)

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting radius MEGA object*2
Size Ambient Other power modes Weight
method temperature FINE
1 m cut not allowed.
-40 to +70°C
ø1.5
ø1.5 FU-49X P.37
ULTRA : 60 (50) Approx. 3 g
15
75 (60) SUPER : 32 (25)
TURBO : 25 (20)
1 m cut not allowed. 20 (16)
-40 to +70°C M3 HSP : 13 (10)
M3
FU-69X P.39
Approx. 3 g
10
R4 ø0.005
Reflective High-flex gold wire
2 m Free-cut (ø1.0 x 2)
-40 to +70°C
ø3
ø3 FU-48 P.37
ULTRA : 130 (110) Approx. 7 g
15 160 (130) SUPER : 70 (55)
2 m Free-cut (ø1.0 x 2) TURBO : 50 (40)
35 (28)
-40 to +70°C HSP : 22 (17)
M4
M4
FU-68 P.39
Approx. 8 g
15

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.)
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

26
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

For use any environment


Oil / Chemical Resistant due to its FEP-sheathed body.
Integrated
Bracket

Flat Bracket

FEP chemical resistance data (Reference)


Chemical
Threaded/
Methyl Hydro- Sulfuric Hex-shaped
Methyl Toluene chloric
Acetone ethyl Benzene alcohol acid
Material ketone acid (98%)

FEP Cylinder
ABS

Polycarbonate Sleeve
Resistant Resistant depending on the conditions Not resistant

Small Spot

Ask the Expert


Call us for Details on
Area
the FU Series

 etro-
R
reflective
RED indicates thrubeam fibres.
Unit: mm
Fibre unit length Detecting distance*1  arrow Field/
N
Type Optical axis
(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model High-Power
Beam Appearance bend (Standard detectable Dimensions
Detecting Ambient radius MEGA object*2
emitting Size Other power modes target to be Weight
method direction temperature FINE detected)
 efinite-
D
2 m Free-cut (ø2.2) reflective
-40 to +70°C ULTRA : 3600 (3600)
3600 (3600) SUPER : 3000 (2400) FU-92
Top
22 TURBO : 2600 (2000)
ø3.7 ø0.2
Approx. 71 g
P.41
1300 (1000) High-flex
ø5 HSP : 750 (400)

Thrubeam ø5 R40
2 m Free-cut (ø2.2)
-40 to +70°C ULTRA : 2200 (1700)  il/Chemical
O
2700 (2200) Resistant
Side
SUPER : 1100 (880) FU-96
TURBO : 880 (700)
ø2.8 ø0.1
Approx. 71 g
P.41
430 (350)
ø5
23
HSP : 240 (160)  eat
H
Resistant

BLUE indicates reflective fibres. Unit: mm


Liquid-level

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model L iquid Crystals/
Beam Appearance bend detectable Dimensions
Detecting Ambient radius MEGA object*2 Semiconductors
emitting Size Other power modes Weight
method direction temperature FINE
2 m Free-cut (ø1.3 x 2)
-40 to +70°C ULTRA : 220 (180)

Reflective R40
220 (180) SUPER : 135 (110) ø0.005 FU-91
Top ø4.5 ø4.5
TURBO : 110 (85) gold wire Approx. 32 g
P.40
75 (60)
20 HSP : 45 (35)

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) “3600” is assumed as maximum because the fibre cable has a length of 2 m.
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.

Applications

Wafer detection (Wet) Wafer detection (Wash)

27
STEP 2 Select a specific sensor

Resists temperatures up to
Heat Resistant 350°C
A wide variety of heat-resistant types, including the
easy-to-install R5 type and the high-temperature fibre
unit, resist temperatures up to 350°C.

Heat resistant Fibres


temperatures
Up to 180°C Plastic
From 200°C Multi-component glass

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Appearance bend (Standard detectable Dimensions
Detecting Heat resistant Ambient radius MEGA Other power modes object*2
method temperatures*3
target to be Weight
temperature FINE detected)

2 m Free-cut (ø2.2)
-40 to +100°C ULTRA : 1100 (850)
1400 (1100)
FU-86Z
*4
100˚C R5 SUPER : 800 (600)
ToughFlex
TURBO : 550 (440) Approx. 25 g
P.40
15 300 (250)
M4 HSP : 190 (110)
Lens attachment P.12
ø1
2 m Free-cut (ø2.2)
-40 to +105°C ULTRA : 1600 (1100)
2300 (1400)
FU-86A
*4
SUPER : 950 (800)
105˚C R25 P.40
15 400 (320) TURBO : 800 (600) Approx. 22 g
M4 HSP : 220 (150)
Lens attachment P.12
2 m Free-cut (ø2.2)
-40 to +150°C ULTRA : 1000 (700)
1400 (880)
150˚C
*5
R20
SUPER : 600 (500) FU-86H P.40
17 TURBO : 500 (380) Approx. 35 g
250 (200)
M4 HSP : 140 (95)
Thrubeam ø1.5 ø0.005
2 m Free-cut (ø2.2)
-60 to +180°C ULTRA : 1000 (800)
*6
R35
1300 (1000) SUPER : 620 (500) FU-88 P.40
180˚C TURBO : 500 (400)
17 Approx. 36 g
250 (200)
M4 HSP : 180 (110)

2 m cut not allowed.


-40 to +200°C

200˚C 10
FU-88K P.40
R8 Approx. 30 g
15
ULTRA : 750 (600)
M4
950 (750) SUPER : 460 (380)
ø1
2 m cut not allowed. TURBO : 380 (300)
180 (150)
-40 to +300°C HSP : 130 (75)

10 R25
FU-84C P.40
300˚C
15 Approx. 66 g
M4
Lens attachment P.12
*1 When using the FS-V30. *2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
*3 Use the fibre sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fibre unit.
*4 The recommended maximum ambient temperature during operation is 90°C when constantly using a fibre unit in a high-temperature environment.
*5 The recommended maximum ambient temperature during operation is 130°C when constantly using a fibre unit in a high-temperature environment.
*6 The recommended maximum ambient temperature during operation is 150°C when constantly using a fibre unit in a high-temperature environment.

Thrubeam type lens attachment can be found on P.12.

28
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Smallest Model
Appearance bend detectable Dimensions
Detecting Heat resistant radius MEGA object*2
method temperatures*3
Ambient Other power modes Weight Flat Bracket
temperature FINE
2 m Free-cut (ø2.2 x 2)
-40 to +100°C ULTRA : 380 (300)
460 (380)
Threaded/
*4 M6 R5 SUPER : 220 (180) FU-85Z Hex-shaped
100˚C ToughFlex
TURBO : 160 (130) Approx. 25 g
P.40
80 (65)
17 HSP : 50 (40)

2 m Free-cut (ø2.2 x 2)
Cylinder
-40 to +105°C ULTRA : 560 (450)
*4
M6
R25
680 (560) SUPER : 370 (300) FU-85A
105˚C TURBO : 250 (200) Approx. 21 g
P.40
120 (100) Sleeve
HSP : 80 (60)
17

2 m Free-cut (ø2.2 x 2)
ULTRA : 360 (290)
-40 to +150°C Small Spot
*5
150˚C M6
R20
430 (360) SUPER : 240 (190) FU-85H
TURBO : 160 (130) Approx. 35 g
P.40
80 (65)
HSP : 50 (40)
17
Area
2 m Free-cut (ø2.2 x 2)
-60 to +180°C ULTRA : 460 (360)
*6
180˚C
M6 570 (460) SUPER : 260 (210) FU-87  etro-
R
R35
TURBO : 180 (140) Approx. 33 g
P.40
90 (70) reflective
17 HSP : 55 (45)
ø0.005
gold wire
1 m cut not allowed.  arrow Field/
N
-40 to +200°C High-Power
200˚C M4 R8 FU-87K
Approx. 15 g
P.40
10  efinite-
D
17
reflective
1 m cut not allowed.
-40 to +300°C ULTRA : 420 (340)
M4
420 (340) SUPER : 260 (210) FU-82C High-flex
Reflective
35 TURBO : 180 (140) Approx. 29 g
P.40
ø2.1 90 (70)
Min. bend radius HSP : 55 (45)
90
of sleeve R10
300˚C  il/Chemical
O
1 m cut not allowed. Resistant
-40 to +300°C
M4 R25 FU-83C
P.40
ø2.6
10
Approx. 23 g  eat
H
17 Resistant
1 m cut not allowed.
-30 to +350°C ULTRA : 360 (280)
M4
400 (360) SUPER : 210 (170) FU-81C
Liquid-level
350˚C P.40
40 TURBO : 150 (120) Approx. 24 g
ø2.1 75 (60)
90 Min. bend radius HSP : 45 (35)
of sleeve R10 L iquid Crystals/
2 m cut not allowed. Semiconductors
-40 to +250°C ULTRA : 8 to 34 (8 to 31)
8 to 37 (8 to 34)
29.7 SUPER : 8 to 32 (8 to 29)
FU-38LK
17.1 TURBO : 8 to 30 (8 to 27) Approx. 70 g
P.36
8 to 30 (8 to 27)
HSP : 10 to 18 (10 to 15)
Thickness: 5
250˚C R25
1 m cut not allowed.
-40 to +250°C
27 FU-38K
19
––
Approx. 45 g
P.36
ULTRA : 2.5 to 55 (2.5 to 44)
Thickness: 5 2.5 to 65 (2.5 to 55) SUPER : 2.5 to 27 (2.5 to 22)
2 m Free-cut (ø2.2 x 2) TURBO : 2.5 to 22 (2.5 to 19)
-40 to +180°C 2.5 to 16 (2.5 to 12)
HSP : 2.5 to 10 (2.5 to 7)
27 FU-38H
180˚C
19
R35
Approx. 45 g
P.36

Thickness: 5

* 1 When using the FS-V30. Standard target: white mat paper (Reflective type only). FU-38LK shows values for t=0.7 mm glass substrate (horizontal direction).
*2 The smallest detectable object was determined at the optimal detecting distance and sensitivity setting.
*3 Use the fibre sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fibre unit.
*4 The recommended maximum ambient temperature during operation is 90°C when constantly using a fibre unit in a high-temperature environment.
*5 The recommended maximum ambient temperature during operation is 130°C when constantly using a fibre unit in a high-temperature environment.
*6 The recommended maximum ambient temperature during operation is 150°C when constantly using a fibre unit in a high-temperature environment.

29
STEP 2 Select a specific sensor

Liquid-level sensors come in tube-


Liquid-level mountable and immersible types.

FU-95 Series FU-93 Series


Solenoid Valve
Oil Tank
Water

Cleaning
liquid
Detecting
presence/absence Detecting the operating oil level
and fill level of cleaning liquid for a press

Ask the Expert


Call us for Details on
the FU Series

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length


(Diameter) Minimum Model
Appearance bend Accessory Dimensions
Detecting Transparent Beam Ambient radius Weight
method tube diameter axis temperature
2 m Free-cut (ø2.2 x 2)
-40 to +70°C

16 R5
Binding band x 2 FU-95S P.41
Nonslip rubber x 2 Approx. 23 g

2 m Free-cut (ø1.0 x 2)
FU-95Z: -40 to +50°C
FU-95HA: -40 to +105°C*
FU-95: -40 to +70°C R2 FU-95Z P.41
ToughFlex Approx. 7 g

ø4 to 26

Binding band x 2
Tube-mountable 1 R25
Nonslip rubber x 2 FU-95HA P.41
Spacer x 2 Approx. 7 g
Screw x 2
Nut x 2

* The recommended maximum R10 FU-95 P.41


ambient temperature during Approx. 7 g
operation is 90°C when constantly
using a fibre unit in a
high-temperature environment.

2 m Free-cut
(ø2.2 x 2)
-40 to +70°C
More than ø26
16 R5
— FU-95W P.41
recommended (Optionally available) Approx. 20 g

Unit: mm

Type Fibre unit length Minimum bend radius


(Diameter) Model
Appearance Dimensions
Detecting Ambient PFA-sheathed section Fibre Weight
method temperature
2 m Free-cut (ø1.3 x 2)
FU-93Z: -40 to +50°C
FU-93: -40 to +70°C R0.5 FU-93Z P.41
ToughFlex Approx. 78 g

Immersion R40*

ø6 (PFA)
R25 FU-93 P.41 * Not bendable up to
Approx. 78 g 80 mm from the tip.

30
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

Selection Guide Beam axes of tube-mountable type Integrated


Bracket

Sixteen
beam axis eliminate problems Using a single beam axis was
Flat Bracket

caused by air bubbles and water droplets. normal in the past, this resulted
in mis-operation caused by Threaded/
Detection relies on a series air bubbles, droplets, and other Hex-shaped
of 16 beam axis, so even problems. The 16-axis type is a
if an object such as an air suitable countermeasure against
Cylinder
bubble affects one or more It does not these problems.
matter if an air
axes, the remaining axes bubble affects
continue to operate normally a few beam
axes.
Sleeve
and detect the liquid level.
Small Spot

For ø4 to ø26 tubes For tubes ø26 and greater FU-95W Options
Area
FU-95S FU-95W OP-82177
Binding band x 2, Nonslip rubber x 2
Can be used on pipe diameters of ø26 to  etro-
R
ø80 mm. reflective

Detection Detection
range: range: Bindng band (2)  arrow Field/
N
16 mm 9 mm High-Power

Nonslip  efinite-
D
rubber (2) reflective

High-flex

Detection principle
 il/Chemical
O
Resistant
FU-95 Series FU-93 Series
There is a wide difference in the refractive There is a wide difference in the refractive index between the fluorine
Without liquid
index between a tube with no liquid inside resin and air when the tip of the sensor is in the air.  eat
H
and air. The light beam reflects inside The total reflection of the light beam occurs and the light beam goes Resistant
a tube and goes back to the receiver. back to the receiver. On the other hand, when the tip of the sensor is
On the other hand, the difference in the in the liquid, the difference in the
Liquid-level
refractive index between a tube filled with refractive index between the fluorine
liquid and the liquid is narrow. Most of the With liquid resin and the liquid narrows. Most of Air
light beam is absorbed by liquid and no the light beam is absorbed by liquid Liquid
L iquid Crystals/
light beam goes back to the receiver. The and no light beam goes back to the Semiconductors
FU-95 Series fibres detect the presence receiver. The FU-93 Series fibres Air
of liquid using these characteristics. detect the presence of liquid using Liquid
these characteristics.

Hints on correct use


● Use the timer if chattering occurs due to dripping ● A tube, whose wall thickness is 3 mm, or greater,
or bubbles in the liquid. may make detection difficult. (FU-95 Series)
● Do not pull or push the fibre unit. 30N every three ● FU-95 Series cannot be used for opaque tubes.
seconds maximum for the FU-93 Series, and ● Use the display scaling function of the FS-V30
10N every three seconds maximum for the FU-95 Series to adjust the displayed light intensity.
Series.
● With the FU-93/93Z, the sensor and PFA case
● Stable detection may not be possible in the are inserted into a thermo fitted tube 80 mm, up to
following cases (FU-93 Series): the tip, in order to secure them in place. Take care
If a bubble adheres to the tip of the sensor; to avoid cutting this tube, will result in looseness.
If a foreign material adheres to the tip of the
sensor;
Highly adhesive liquid;
High temperature liquid such as strong acid or
strong alkali (Liquid with PFA mixed or penetrated,
or fluorinated acid.); and Opalescent liquid or liquid
that colours PFA.

31
STEP 2 Select a specific sensor

Perfect for glass substrate detection.


Liquid Crystals/Semiconductors A wide variety of types including
distance alignment, heat-resistant
type, and more.

FU-38L
Long-distance
alignment FU-40S
End surface
detection FU-38LK
Long-distance alignment
(High-temperature Type)

Ask the Expert


Call us for Details on
the FU Series

RED indicates thrubeam fibres.


Unit: mm

Type Fibre unit length Detecting distance*1 Optical axis


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON.
diameter Smallest Model
Beam Appearance bend (Standard detectable Dimensions
Detecting emitting Aperture Ambient radius MEGA Other power modes object*2
method
target to be Weight
direction Angle temperature FINE detected)

2 m Free-cut (ø1.0)
-40 to +70°C ULTRA : 700 (650)

Mapping Side
Approx.
R10
850 (800) SUPER : 360 (330)
ø1 ø0.02 FU-18M P.34
3° 1.5 TURBO : 300 (280) Approx. 6 g
240 (220)
2 HSP : 130 (110)
20

BLUE indicates reflective fibres. Unit: mm

Type Fibre unit length Detecting distance*1


(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Model
Beam Appearance bend Dimensions
Detecting Ambient radius MEGA
emitting Other power modes Weight
method temperature
direction FINE
2 m Free-cut (ø2.2 x 2)
-40 to +70°C
ULTRA : 15 to 60 (15 to 54)

Glass substrate 15 to 70 (15 to 62) SUPER : 15 to 46 (15 to 40) FU-40S


Mapping Top
TURBO : 15 to 38 (18 to 33) Approx. 25 g
P.36
7.4 18 to 30 (20 to 25)
HSP : −
17
19
R25
2 m Free-cut (ø2.2 x 2)
-10 to +60°C
ULTRA : 8 to 36 (8 to 33)
14
8 to 38 (8 to 35) SUPER : 8 to 35 (8 to 32) FU-38L
TURBO : 8 to 34 (8 to 31) Approx. 20 g
P.36
8 to 32 (8 to 29)
20 HSP : 10 to 26 (10 to 23)
Thickness: 5.2
2 m Free-cut (ø2.2 x 2)
-40 to +70°C
20.5 ULTRA : 0 to 25 (0 to 25)

Glass substrate
0 to 25 (0 to 25) SUPER : 0 to 25 (0 to 25) FU-38S
Alignment
R5
TURBO : 0 to 25 (0 to 25) Approx. 20 g P.36
0 to 25 (0 to 25)
29 HSP : −

Thickness: 3.6
Flat
2 m Free-cut (ø2.2 x 2)
-40 to +70°C
22 ULTRA : 0 to 14 (0 to 14)
0 to 14 (0 to 14) SUPER : 0 to 14 (0 to 14) FU-38R
R25
TURBO : 0 to 14 (0 to 14) Approx. 20 g P.36
0 to 14 (0 to 14)
29 HSP : 0 to 12 (0 to 9)

Thickness: 3.8

2 m Free-cut (ø1.0 x 2)
-40 to +70°C ULTRA : 0 to 4 (0 to 4)
12 0 to 4 (0 to 4)

Seating check R10


SUPER : 0 to 4 (0 to 4) FU-38V P.36
TURBO : 0 to 4 (0 to 4) Approx. 5 g
0 to 4 (0 to 4)
19 HSP : 2±1.4 (2±1.4)

Thickness: 4.3

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) (Excluding FU-40S, FU-38L)
FU-40S values for a t=0.7 mm glass substrate R surface (end direction) FU-38L shows values for t=0.7 mm glass substrate (horizontal direction).

32
1 2 3
Select a Select a Select an
sensor specific amplifier
type sensor

BLUE indicates reflective fibres. Unit: mm


Integrated
Bracket
Type Fibre unit length Detecting distance *1

(Diameter) Minimum Each detecting distance in parentheses shows the data when the S-APC function is ON. Model
Heat Beam Appearance bend Dimensions
Detecting radius MEGA Flat Bracket
Resistant emitting Ambient Other power modes Weight
method Temperatures*2 direction temperature FINE
2 m cut not allowed.
-40 to +250°C
ULTRA : 8 to 34 (8 to 31) Threaded/
8 to 37 (8 to 34) SUPER : 8 to 32 (8 to 29) FU-38LK P.36 Hex-shaped
TURBO : 8 to 30 (8 to 27) Approx. 70 g
17.1 8 to 30 (8 to 27)
29.7 HSP : 10 to 18 (10 to 15)

250°C
Thickness: 5 Cylinder
R25
1 m cut not allowed.
-40 to +250°C
Flat
Heat-resistant FU-38K P.36 Sleeve
Glass substrate Approx. 45 g
Alignment 19 27 ULTRA : 2.5 to 55 (2.5 to 44)
2.5 to 65 (2.5 to 55)
Thickness: 5 SUPER : 2.5 to 27 (2.5 to 22)
2 m Free-cut (ø2.2 x 2) TURBO : 2.5 to 22 (2.5 to 19) Small Spot
2.5 to 16 (2.5 to 12)
-40 to +180°C HSP : 2.5 to 10 (2.5 to 7)

180°C R35 FU-38H P.36


Approx. 45 g
19
Area
27
Thickness: 5

* 1 When using the FS-V30. Standard target: White mat paper (Reflective type only.) FU-38LK shows values for t=0.7 mm glass substrate (horizontal direction).  etro-
R
*2 Use the fibre sensor under dry conditions. Allow some margin for the temperature upper limit when selecting a heat-resistant fibre unit. reflective

 arrow Field/
N
High-Power

Selection Guide  efinite-


D
reflective
FU-18M
Perfect for wafer mapping High-flex
Vertical adjustment Adjustment Mouting brackets
only not required. included  il/Chemical
O
Rotary direction adjustment Special brackets are provided Resistant
not required, which reduces to make installation easier.
installation time. Easy installation in existing  eat
H
devices. Resistant
Vertical
adjustment only

Liquid-level

FU-40S L iquid Crystals/


Semiconductors
No problem, even if the detecting No problem, even at an angle
distance changes 1000
A high-power, large-aperture, 100
Thickness: 0.7 aspherical lens performs
Received light intensity
Received light intensity

A high-power, large-aperture, 800


rate of change (%)

80
Thickness: 0.5 exceptionally even at an
aspherical lens provides 600 angle. 60
coverage for a wide range of T Side
400 40
distances.
200 20

0 0
20 40 60 80 -10 -5 0 5 10
Detecting distance (mm) R Side Angle (°)

Detecting distance vs. Received Angle characteristics (Typical)


light intensity (Typical) Detecting distance: 30 mm 0.7 mm thick
R Surface of Class Substrate for Liquid Crys- glass substrate for liquid crystal, R surface
tal (ULTRA APC OFF)

FU-38L/38LK/38S
High-accuracy detection at distances of Stable detection of substrates at angles of:
8 mm to 30 mm Horizontal: ±6°, Vertical: ±3°
Positioning accuracy of Stable detection Horizontal Vertical
0.2 mm or less is maintained Error: 0.2 mm max. is possible even
even if the distance to the when the glass ±6° ±3°
glass substrate changes substrate is at an
within a range of 8 mm to 30 mm angle.
30 mm.
* the FS-V31 Series TURBO mode,
APC OFF 8 mm
* ±8° for FU-38S. * Not defined for the FU-38S.
* FU-38S provides positioning
accuracy of 0.2 mm or less at
distances from 5 mm to 17 mm.

33
Fibre Unit Dimensions Diagram

Unit: mm

FU-10 Free-cut Two-sided


Chamfering ø6 A M6, P=0.75 mounting part transmitter Mounting bracket
4 2 -Slotted hole
2
Reflective
M6 nut, M6 washer, tooth locked washer provided. (Included with FU-10)
10
ø6
ø5.5 A 3 ø1.3 x 2 (Adaptor A) 2 4
5.2
lens 5
A-A 2.6 10 9.6 * 23.5
L 2000 18 M3 screw
cross
section view L: lens unit length *adjustable part 4.2 to 9.3
21.5 18 t=1.5

FU-11 Free-cut FU-12 Free-cut 4.2 3 6.4 (Centre of optical axis)


Reflective Centre of Thrubeam 10
2-ø3.3 ø2.2 x 2 transmitter 2-ø3.2, ø6.6 spot facing ø2.2
emitted light
mounting hole
20 16
15 9 10
3.9 12
3.6 20
7 28 2000 Set of 2
23.3 2000
2

FU-13 Free-cut 3 Reflective tape (Included with FU-13)


4.2 OP-96629
Reflective
Across-flats:10, t=2 40
ø1.6 x 2
2 openings M6, P=0.75 ø1 x 2
(Adaptor B) 30
Material: PC, Acryl
Retro-reflective t=0.7
17 2000

FU-15 Free-cut
Centre of 2-ø3.2 2-C1.5 R-2 Reflector Mounting bracket Plate nut
optical axis (Mounting (Included with FU-15) (Included with FU-15) (Included with FU-15)
Reflective 7.5 ø1 x 2
hole) 47 30.5
(Adaptor B)
8 (21.5) 20 14
94 20.8 14 25.6
8 2
47 51.2 2-M3,
61 6
30.4 P=0.5
Retro-reflective 3.4 stainless steel
7.8 7.7
23.2 11 4.2 6.8 t=1.5
12.6 26.9 2-ø4.5 4.2
21.5
39 2000 30 3.5 14
40 5.5 3.8 3.5 3 3
51.2 8
5.8 Material: Acryl, ABS
8 14 3.5 stainless steel
37.5 t=1.2
Supplied screws
(Included with FU-15)
15.5 M3 x 18 (2 pcs.)

FU-16/16Z/18 Free-cut Mounting bracket (Included with FU-16/16Z/18) (2 pcs.)


Thrubeam ø2.5 (Beam dia.)
2 x R1.6 5.7 5.3
3.6 3 ø4 ø1 (Adaptor B)
stainless steel 10
1.8 18 3.2 4.5
Set of 2 17 13 2000
t=0.5, stainless steel

FU-18M Free-cut
Mounting bracket (Included with FU-18) (2 pcs.)
ø1 (Beam dia.) t=1.0
Thrubeam stainless steel
stainless steel 15 9.9
2 ø1.0 (Adaptor B)
0.8 2.5 2.1
9.1 0.2 1.5
20 2000
Set of 2
1.5 5.1 2

FU-20 FU-21X
Across-flats: 5.4, t=2
Reflective ø2.75 ø3 ø1.6 transmitter Reflective ø0.25 M3, P=0.5 ø1.5
lens core fibre Nickel-plated brass
*9 ø0.125 x 10
18 500 15 500
core fibre
*Set-screw tightening area

34
Fibre Unit
Dimen-
CAD Data Download Service www.keyence.com/cad sions
Diagram

Unit: mm

FU-22X ø1.77 FU-2303 Across-flats: 5.4, t=2


stainless steel ø0.5
Reflective ø0.5 Reflective core fibre M3, P0.5 ø3.5
core fibre ø2.5 ø2.0 stainless steel stainless steel
stainless steel
ø4.5
9 x ø0.25 8 x ø0.265
13
14 500 core fibre
1000
core fibre 6 5

FU-23X FU-24X
Across-flats: 5.4, t=2
Reflective ø1 ø3 ø2.2 Reflective ø0.175 x 9 M3, P=0.5 ø1.5
core fibre stainless steel core fibre Nickel-plated brass
ø0.25 x 16
17 500
core fibre
15 500

FU-25 Free-cut Across-flats: 10, t=2


FU-2540 M6, P0.75
ø1.0 M6, P=0.75 ø2.2 x 2 mounting part ø4.5 ø3.5
Reflective core fibre Reflective ø6 A stainless steel
Nickel-plated brass stainless steel
ø4
ø5.5 A'
16 x ø0.25 3 14 2000 5.2 lens 10 9.6
*
5

core fibre 2.6 L 2000


A-A' L: lens unit length *adjustable part 4.2 to 9.3
cross
section view

FU-31 Free-cut ø2
FU-32 Free-cut ø0.82
stainless steel
2 stainless ø2.8 ø0.6 (Beam dia.)
Reflective Thrubeam
0.5 steel ø1.0 x 2 (Adaptor B) 2.3 ø2.5 ø1.3 (Adaptor A)
stainless steel 0.6 stainless steel

1 15 15 2000 15 15 1000
Set of 2

FU-33 Free-cut FU-34 Free-cut


Reflective 2.3 2.5
ø2.1 ø4.8 ø2.2 x 2 Thrubeam ø1.2 ø3.0 ø2.2
stainless steel stainless steel 2 2.5 stainless steel stainless steel
0.4
1
10
Bendable area
5 10 Bendable area
5
65 15 1000 65 15 1920
Set of 2

FU-35FA Free-cut
Across-flats: 5.4, t=2 FU-35FZ Free-cut
Across-flats: 5.4, t=2
Reflective
ø0.5 M3, P=0.5 ø1.3 x 2 Reflective ø0.5 M3, P=0.5 ø1.3 x 2
core fibre stainless steel (Adaptor A) core fibre stainless steel (Adaptor A)

8 x ø0.265 ø3 8 x ø0.265 ø3
core fibre 18 5 1000 core fibre 12 5 1000

FU-35TG M6, P=0.75 Effective screw length: 12 Nickel-plated brass FU-35TZ Free-cut M3, P=0.5 Effective screw length: 12
M3, P=0.5 Effective screw length: 3.5 Nickel-plated brass ø1.3 x 2
Reflective ø0.5 core fibre ø3.5 stainless steel Reflective ø0.5 core fibre (Adaptor A)
11.5 8.1
1000 1000
8 x ø0.265
ø0.265 x 8 4 core fibre 12.5
core fibre
12.5
6 (M6 nut and washer included) 6 (M3 nut and washer included)
10 7

FU-37 Free-cut 5 FU-38 Free-cut 2-ø3.2, ø6.2 spot facing


3
Reflective
2-ø3.4, ø6 spot facing Reflective
mounting hole ø1 x 2 (Adaptor B)
mounting hole ø1 x 2 (Adaptor B)
14.4 8.4 12
4 6 5.5 3.5
7 7
19 2000
19 2000
Housing: Polycarbonate Housing: Polysulfone

35
Fibre Unit Dimensions Diagram

Unit: mm

FU-38H Free-cut 3
6.5 FU-38K 6.5
2-M3, P=0.5 ø2.2
3 2-M3, P=0.5
Reflective Reflective 19 Spiral: ø2.9

8 8

19 15 12
5 15 12 1.6
2000 5 10
1000

FU-38L FU-38LK
ø2.9 x 2
Free-cut (20) 2000 5 20 6.5 2-ø3.2, ø6 stainless
6.5 4.2 4.6 0.8 spot facing
(9.3) steel
Reflective 5.2 6.5 2-ø3.2, ø6 spot facing Reflective
17.1 8

14 10.5 lens 29.7


33.9
ø2.2 x 2 1500 480 20 (26.4)
1.1 (-40 to +250°C) (-40 to +200°C) (−40 to +70°C) (-40 to +55°C)
(20)* *Do not bend this part.
2000

FU-38R Free-cut 2-ø3.5, ø6.2 spot facing FU-38S Free-cut 2-ø3.5, ø6.2 spot facing
mounting hole mounting hole
Reflective ø2.2 x 2 Reflective ø2.2 x 2
8.2
22 20.5
2.3 1.7
13.9 6.5
3 14.9 6.5 (4.6)
29 (20)* 3.6 29 2000
3.8 2000
*Do not bend this part.

FU-38V Free-cut 2-ø3.2, ø6.2 spot facing ø1 x 2 FU-4F/4FZ Free-cut


ø1.3 x 2
mounting hole (Adaptor B)
Reflective Reflective 2 x ø1 ø3 (Adaptor A)
12 core fibre
stainless steel
5.5 3.5
7
4.3 2000 17 2000
19
Housing: Polysulfone

FU-40 Free-cut
ø3.7 x 2 ø2.2 x 2
FU-40G ø3.7 x 2
2-ø4.0
ø2.9 x 2
lens Nickel-plated
Reflective lens Reflective brass stainless steel

9.5 4.4 9.5 4.4


21 2000 21 7
5.2 5.2 stainless steel
stainless steel 1000

Mounting bracket 20
(Included with FU-40 / 40G) 10 2-M3
6.4
23 12
1
3.3 2-Slotted hole
1 3.3
6.1 10 t=1.6

FU-40S Free-cut
7.4 2-ø5.7
19 2000 FU-41TZ Free-cut
7 2-ø2.1, ø3.6 spot facing d=1.4
Reflective
8.2 7 2-ø3.5, ø6 spot facing
Reflective
8 2 M2, P=0.4 x 6 screw/nut provided

13
7.3 17 ø1.0 (Adaptor B)
1.5
(20)* ø2.2 x 2 2 4.5
1000
*Do not bend this part.
Housing: stainless steel

FU-42TZ Free-cut 7 2-ø3.2, ø5.7 spot facing d=2.1 Mounting bracket


(Included with FU-42TZ) 14.5
M3, P=0.5 x 7 screw/nut provided 41.3 5
Reflective 5.5
25.4 6.4
20 13 3 3.5
4
ø2.2 x 2 3.5 15 7
7 22
4 1.5 2000
3
3.5 3.5
Housing: stainless steel 3
t=1.2, stainless steel

36
Fibre Unit
Dimen-
CAD Data Download Service www.keyence.com/cad sions
Diagram

Unit: mm

FU-43 Free-cut
ø1.3 FU-44TZ Free-cut 2 2-ø2.1
ø4 1.2 2-ø0.5 8 M2, P=0.4 x 6
Reflective ø1.65 ø1.3 x 2
(Adaptor A) Reflective core 2 screw/nut provided
ø0.5 x 2 stainless stainless
core fibre steel steel 6.5 fibre
ø1.0 x 2 (Adaptor B)
1.4
2 20* 15 2000 2 4 1000
*Do not bend this part. Housing: stainless steel

FU-45X ø0.82 FU-46 ø0.5 ø1.5


stainless steel
ø0.125 x 4 stainless ø0.9
Reflective ø0.265 x 2 ø3 ø1 Reflective
core fibre steel
stainless
steel
core fibre stainless steel

* 15 500 15 1000
5 3
*Do not bend this part.

FU-47TZ Free-cut
2.5 10.5
2-ø2.1 FU-48 Free-cut
ø3
M2, P=0.4 x 6 screw/nut provided
Reflective 2.5 Reflective (ø0.265 x 4) x 2 stainless ø1.0 x 2 (Adaptor B)
7.2 ø1.0 x 2 (Adaptor B) core fibre steel
ø0.5 44 1000
core fibre 15 2000
Housing: stainless steel
1
1

FU-49X FU-5F/5FZ Free-cut


ø3
ø1.5 ø1 ø2.2
Reflective Thrubeam ø1 (ø1.13) stainless steel
ø0.265 x 4 stainless steel
core fibre
core fibre
15 2000
15 1000 (14)
*( ) shows FU-5FZ.
Set of 2

FU-50 Free-cut Mounting bracket FU-51TZ Free-cut 2-ø2.1, ø3.6 spot facing d=1.4
stainless (Included with FU-50)
M2, P=0.4 x 6 screw/nut provided
Thrubeam 4 steel ø1.0 Thrubeam 3 2.5 ø1.0 (Adaptor B)
(Adaptor B) 5.7 5.3
2-R1.6
3.6 10 5
ø2.8 12 2000 10 1000
lens 1.8
10
18 3.2 ø0.5 core fibre Housing: Aluminium
Set of 2 4.5 Set of 2
t=0.5, stainless steel

FU-52TZ Free-cut 2-ø3.2, ø5.7 spot facing d=2.1 FU-53TZ Free-cut 2-ø2.1, ø3.6 spot facing d=1.4
M2, P=0.4 x 6 screw/nut provided
3.5 3.5 M3, P=0.5 x 7 screw/nut provided
Thrubeam
Thrubeam 1.5
ø1.3 (Adaptor A) ø0.5 core fibre
2 6.5
14 7 ø1.0 (Adaptor B)
13 8
14 2000
4.5 1000
Housing: Aluminium
Set of 2 ø1.0 core fibre Set of 2 7 Housing: Stainless steel

FU-54TZ Free-cut
2-M3, P=0.5 x 5 screw/nut provided Mounting bracket 6.4
15
3.5 3
1.5 (Included with FU-54TZ, 2 pcs.)
22 3
Thrubeam ø1 core fibre
7.5 ø2.2
14.5 5 25.4
15 10
41.3
3.5
5.5 3.5
4.5 2000 3.5
4 7 Housing: Stainless steel 47 7
Set of 2

FU-55 ø0.125 ø2.5 FU-56 ø0.125


ø0.3
Stainless ø2.5
ø1 steel
Thrubeam core fibre Nickel-plated brass Thrubeam core Nickel-plated brass
fibre ø1.3

2 per set
10 500
Set of 2
5 10 500

37
Fibre Unit Dimensions Diagram

Unit: mm

FU-57TE/57TZ Free-cut FU-57TE


1
FU-57TZ
1
FU-58 ø0.265 ø1
core Stainless steel
Thrubeam ø0.265 x 4 ø0.5 Thrubeam fibre ø0.7
core fibre VIEW A core fibre VIEW A

2-ø2.1, ø3.6 spot facing d=1.4


M2, P=0.4 x 6 screw/nut provided
Set of 2 2 per set
6 500

ø1.0 (Adaptor B)

2.5
A
FU-59 Free-cut

4 4 Thrubeam ø1.5 ø1.0 (Adaptor B)


ø0.265 x 4
6 core fibre
Stainless steel

2.5 1000 10 1000


10.5 Housing: Stainless steel
Set of 2

FU-6F Free-cut
Across-flats: 10, t=2 FU-61/61Z Free-cut
Across-flats: 10, t=2
ø1.5 x 2
ø1 x 2 M6, P=0.75
Reflective M6, P=0.75 ø2.2 x 2 Reflective core fibre 2 x ø2.2
core fibre Nickel-plated brass Stainless steel
ø4 ø4

3 14 2000 3 14 2000

FU-63 Free-cut
10
Bendable area
5
Across-flats: 7, t=2 FU-63T Free-cut
ø0.5 x 2 ø1.65
t=3
ø1.65 M4, P=0.7 core fibre ø1.3 stainless 3
Nickel-plated brass
Reflective ø0.5 x 2 Nickel-plated Reflective 2 x ø1.3 (Adaptor A)
stainless steel
core steel brass
fibre 10
ø1.3 2-ø3.4
ø1.3 x 2
Sleeve Sleeve Bendable area 3
tip (Adaptor A) tip 10 5 9.5
2 65 15 2000 2 65 15 2000

FU-63Z Free-cut
10
Bendable area
5 Across-flats: 7, t=2 FU-65X ø0.82 Across-flats: 5.4, t=2
ø2.0 ø0.265 x 2 stainless
M3, P=0.5
Reflective ø0.65 x 2 stainless M4, P=0.7 Reflective steel ø1
core stainless steel core fibre Nickel-plated brass
steel
fibre
Sleeve ø1.65 ø1.3 x 2
15* 15 500
tip (Adaptor A)
*Do not bend this part.
2 65 15 2000

FU-66/66Z Free-cut
Across-flats: 7, t=2
FU-66TZ Free-cut M4, P=0.7 Effective screw length: 6.5
ø1 × 2 (ø1.13 × 2) Nickel-plated brass
Reflective
core fibre M4, P=0.7 ø1.3 × 2 (Adaptor A) Reflective ø2.6 2 x ø1 core fibre ø1.3 × 2
stainless steel 8.1
2000
ø2.6
2000
3
3 12 7
*( ) shows FU-66Z. 3.5 (M4 nut and washer provided)
7

FU-67/67V Free-cut Across-flats: 10, t=2 FU-67G Across-Flat: 10, t=2


ø1.13 × 2 M6, P=0.75 ø2.2 × 2
ø1.13 × 2
M6, P=0.75 ø3.8
Reflective Nickel-plated brass Reflective core fibre stainless steel
core fibre Nickel-plated brass
ø4
ø4
3 13
2000
2 15
1000

FU-67MG ø1.13 x 2 FU-67MTG


core fibre M6 x 0.75 Nickel-plated brass M6 x 0.75
Reflective ø8.5 Reflective Effective screw length: 7.5
ø7.2 ø7.2
stainless steel Nickel-plated brass
ø4 ø1.13 x 2 stainless steel
9 core fibre
ø4
2 15 12
8.5 15 9
12
29 1000 8.5
1000 3
8
9.5

13

38
Fibre Unit
Dimen-
CAD Data Download Service www.keyence.com/cad sions
Diagram

Unit: mm

FU-67TG M6, P=0.75 Effective screw length: 7.5 Nickel-plated brass FU-67TZ Free-cut M6, P=0.75 Effective screw length: 7.5
Nickel-plated brass
ø4 ø1.13 × 2 core fibre ø3.8 stainless steel Reflective ø4
Reflective ø1.13 × 2 core fibre ø2.2 × 2
11.5 11.5
1000
3 2000
8 3
6 (M6 nut and washer provided) 8 (M6 nut and washer provided)
4.8
10 10

FU-68 Free-cut Across-flats: 7, t=2 FU-69X


ø1.0 x 2 Across-flats: 5.4, t=2
Reflective (ø0.265 × 4) × 2 M4, P=0.7 (Adaptor B) Reflective ø0.265 × 4 M3, P=0.5 ø1
core fibre stainless steel
core fibre Nickel-plated brass
ø3
3 12 2000 10 1000

FU-7F Free-cut
Across-flats: 7, t=2 FU-71/71Z Free-cut

M2.6, P=0.45 Across-flats: 10, t=2


M4 P=0.7
Thrubeam
ø1
M4, P=0.7 Thrubeam
M6, P=0.75
Nickel-plated brass ø2.2 ø1.5 stainless steel ø2.2
core fibre core fibre

3 2000 4 2000
12 12
Set of 2 Set of 2

FU-73 Free-cut
ø1.65 Across-flats: 7, t=2 FU-75F Free-cut ø0.82 stainless steel
ø1 ø1.3 stainless M4, P=0.7 Across-flat: 5.4, t=2
ø1.0
Thrubeam steel Thrubeam
core
fibre
Nickel-plated brass
ø0.5 M3, P=0.5 (Adaptor B)
Bendable core Nickel-plated brass
ø2.2
area fibre
Sleeve 10 5 Sleeve
tip tip * 1000
2 65 15 2000 15 15 * Do not bend this area.
Set of 2 Set of 2

ø0.4
FU-76F Free-cut
stainless ø3 FU-77/77V Free-cut M2.6, P=0.45
ø0.265 steel Across-flats: 7, t=2
Thrubeam core Nickel-plated brass Thrubeam
fibre ø1.13 M4, P=0.7 ø2.2
10 Bendable 5 ø1.0 (Adaptor B) Nickel-plated brass
area core
fibre
Sleeve
tip 45 15 1000

Set of 2 Set of 2
3 11 2000

FU-77G Across-flats: 7, t=2 M4, P=0.7 FU-77TG A


ø1.13 core fibre
M2.6, P=0.45 Nickel-plated brass
Thrubeam ø2.9 Thrubeam A M2.6, P=0.45 Effective screw length: 2.5 Nickel-plated brass
stainless steel 3 M4, P=0.7 Effective screw length: 6.5
ø4 7
5
7 ø2.9 stainless steel
ø1.13
8.1 1000
12.0
3 12
2 per set fibre 22 Set of 2 (M4 nut and washer provided)
1000

FU-77MG M2.6 x 0.45


FU-77MTG M2.6 x 0.45
Effective screw length: 2.5

Thrubeam M4 x 0.7 Nickel-plated brass Thrubeam M4 x 0.7


Effective screw length: 6.5
ø7
ø7 Nickel-plated brass Nickel-plated brass
ø5.8
stainless steel A A ø5.8
3 ø2.9
stainless steel stainless steel
7
14
ø1.13 core fibre 8

10 12
8
3 12
11.5
1000 (50) 12
12
ø1.13
27 core fibre
1000

View from arrow A-A

FU-77TZ Free-cut A
ø1.13 core fibre FU-78 Free-cut M2.6, P=0.45
Across-flats: 7, t=2
Thrubeam A M2.6, P=0.45 Effective screw length: 2.5 Nickel-plated brass Thrubeam
M4, P=0.7 ø1.3
3 M4, P=0.7 Effective screw length: 6.5 ø2.2 ø0.265 × 8
Nickel-plated brass
(Adaptor A)
7 core fibre
4.4
8.1 7 2000
3 12 2000
Set of 2 (M4 nut and washer provided) Set of 2

39
Fibre Unit Dimensions Diagram

Unit: mm

FU-79 Free-cut
Across-flats: 5.4, t=2
FU-81C ø2.1 Across-flats: 7, t=2
ø1.45 ø1.85 stainless
steel
M4, P=0.7
Thrubeam
ø0.265 × 4 M3, P=0.5 Reflective core fibre stainless steel ø3.8
core fibre Nickel-plated brass
Bendable area 5
5 15 25 15 ø5
ø1.0 (Adaptor B) Sleeve
90 1000
tip 500 480 20
10 1000 (-30 to +350°C)* (-30 to +200°C)* (-30 to +70°C)*
Set of 2
* Maximum temperature resistance for each part is shown in ( ).

FU-82C Across-flats: 7, t=2


Hexagonal clasp
M4, P=0.7
stainless steel
FU-83C Across-flats: 7, t=2 M4, P=0.7 stainless steel
ø4.2
ø4.2 ø1.45
Reflective ø1.45 ø2.1 Reflective core ø2.6 Hexagonal clasp
core stainless steel Hexagonal clasp
fibre
fibre ø3.4 stainless steel
Bendable area ø3.4
20 5 25 10 3 14 10
Sleeve 90 stainless steel 1000
tip 1000 500 480 20
500 480 20
(-40 to +300°C)* (-40 to +300°C)* (-40 to +70°C)* (-40 to +300°C)* (-40 to +200°C)* (-40 to +70°C)*

* Maximum temperature resistance for each part is shown in ( ). * Maximum temperature resistance for each part is shown in ( ).

FU-84C Across-flats: 7, t=2


M2.6, P=0.45
M4, P=0.7 stainless steel
ø4.2
FU-85A Free-cut Across-flats: 10, t=2

Thrubeam Hexagonal clasp Reflective ø1 × 2 M6, P=0.75 ø2.2 × 2


ø1 core fibre stainless steel
core fibre
ø2.9 stainless steel ø4
3
15 10 3 2000
1500
2000
480 20 14
2 per set (-40 to +300°C)* (-40 to +200°C)* (-40 to +70°C)*
* Maximum temperature resistance for each part is shown in ( ).

FU-85H Free-cut Across-flats: 10, t=2 FU-85Z Free-cut Across-flats: 10, t=2
M6, P=0.75 ø1 × 2 M6, P=0.75
Reflective 2-ø1.5 ø2.2 × 2 Reflective ø2.2 × 2
ø5.1 stainless steel core
core stainless steel
fibre fibre
ø4
13 ø6
1 3 2000
17 2000 14

FU-86A Free-cut
Across-flats: 7, t=2
FU-86H Free-cut Across-flats: 7, t=2
M2.6, P=0.45 M4, P=0.7
Thrubeam
ø1 M4, P=0.7 Thrubeam ø1.5
ø2.9 Nickel-plated brass
ø2.2 core
core fibre stainless steel
fibre
ø4 ø2.2
3 12 2000 1 13
Set of 2 Set of 2
17 2000

FU-86Z Free-cut
Across-flats: 7, t=2
FU-87 Free-cut ø1.5 × 2
Across-flats: 10, t=2
M2.6, P=0.45
Thrubeam ø2.2 Reflective core fibre M6, P=0.75 ø2.2 × 2
ø1 M4, P=0.7 stainless steel
core stainless steel
fibre ø4.9
2000
3 12 2000
3 13 1
Set of 2

FU-87K Across-flats: 7, t=2 M4, P=0.7 FU-88 Free-cut ø2.9


Across-flats: 7, t=2
stainless steel
Reflective
ø1.45
ø2.6 ø4.2 ø2.9 Thrubeam M4, P=0.7 ø2.2
core ø1.5
core stainless steel
fibre
14 10 Hexagonal clasp fibre
3 20
980 (-40 to +200°C)* (-40 to +70°C)*
1 15 1 2000
1000
Set of 2
* Maximum temperature resistance for each part is shown in ( ).

FU-88K Across-flats: 7, t=2 M4, P=0.7


stainless steel
FU-91 Free-cut ø1.3 × 2
(Adaptor A)
M2.6, P=0.45 ø4.2 ø2.2 ø4.5
Thrubeam Reflective ø4.2
ø1
ø1 × 2 FEP-tube FEP-tube
3 Hexagonal 20 core
core 15 10 clasp (-40 to +70°C)* fibre
fibre
1980 (-40 to +200°C)* (20)
2000 12 Metal casing is inserted.
Set of 2 2000 100
* Maximum temperature resistance for each part is shown in ( ).

40
Fibre Unit
Dimen-
CAD Data Download Service www.keyence.com/cad sions
Diagram

Unit: mm

FU-92 Free-cut ø5 FU-93/93Z Free-cut

ø3.7 FEP-tube ø4 FEP-tube ø2.2 Plastic casing inserted ø6 ø1.3 × 2


Reflective
Thrubeam
lens 7 PFA-tube (Adaptor A)
(12.5)
(22)
(80)
Embed this area in metal casing. 2000 200
Set of 2 2000 100 *Do not bend or cut this portion.

FU-95/95HA/95Z Free-cut *Accessory: binding band x 2


nonslip rubber x 1
FU-95S Free-cut *Accessory: binding band x 2
nonslip rubber x 2
spacer, screw, nut x 2 21.6
Reflective Reflective
(35)
15 5
(0.9) ø2.2 x 2
2-ø3.2 ø1.0 x 2 (18)
8.4 (mounting hole) (Adaptor B)
15.4 21 15.3

11
20 2000 16.4 2000
Housing: Polysulfone Housing: Polyetherimide

FU-95W Free-cut 25 2000


ø2.2 × 2
FU-96 Free-cut
(4.5)
Centre of ø5 FEP-tube
Reflective 5.3 Thrubeam optical axis
17 ø2.8 lens ø4 FEP-tube ø2.2

2 8-R1
5 11.3 5
1.85 (23)
12.5 2-ø2.2 transmitter 16-ø0.265 Set of 2
0.3 Embed this area in metal casing.
5
9 0.6 receiver 16-ø0.265 2000 100
Housing: PBT

FU-E40 Free-cut
22
FU-L41Z Free-cut
2000
ø1.13 × 2
Thrubeam 5.1 Reflective
3
10 core fibre ø2.2 × 2
3
10
Optical axis Detecting area (3 × 40) 8
14
69 4
12.5
4 8.5 2-ø3.4 (mounting hole)
13 17
19.5
8.1

3 6 9 6 18
9 ø2.2 Length 2000
43 3
12
2-3.2 × 6.2 (mounting hole) 6 × 9 spot facing,
d=1 (Both sides)*
*M3 x 8 screw provided

FU-L50Z Free-cut 13 20 2-ø3.4 (mounting hole) FU-L51Z/L52Z/L53Z Free-cut


4 8 10
ø2.2 L1
Thrubeam Thrubeam
4 3 17 2000
14 8.5 2-ø3.4 (mounting hole)
4
2000
3 10 lens (ø3.5) 10 4 ø2.2
ø2.2 2 2
3 10 3 10 12.2
Set of 2 8 Set of 2 8
L2 L2
14 core fibre ø1.13
4
2 L2 ø2.2 2 L2
10 2-ø3.4 (mounting hole) 8
20 12.2
4
2-ø3.4 (mounting hole)
4 8.5
17 Model L1 L2
L1
FU-L51Z 12.2 10
FU-L54Z Free-cut 2 ø1.13 core fibre FU-L52Z 17 15
FU-L53Z 22 20
Thrubeam
10
VIEW A-A
12.8 2-ø3.4 (mounting hole)
4
17
8.5
4 ø2.2
2.8
Set of 2 12.8
8
2000 10
A A
B B ø2.2 2.8 10
8
12.8
4
4 8.5
17 2-ø3.4 (mounting hole)
12.8 10

2 ø1.13 core fibre


VIEW B-B

41
Fibre Unit Dimensions Diagram

Unit: mm

Lens (Option)

F-1 Housing:
Nickel-plated brass
F-2 Housing:
Nickel-plated brass
F-4 Housing: Aluminium
Lens: Glass
F-5 Housing: Aluminium
Lens: Glass
Lens: Acryl Lens: Glass
Thrubeam Thrubeam Thrubeam Thrubeam (0.2)
ø3.7
ø2.8 lens 2-ø3.1
ø4 ø4 ø4.3
16.7
6 7.9 9.5 12.4 5.5
2 per set 9.5 2 per set 2 per set 2 per set 7.4 2
(Knurled nut attached.) 5.6 9.3

F-2HA Housing: Aluminium


Lens: Plastic
F-3HA Housing: Aluminium
Lens: Plastic
F-4HA Housing: Aluminium
Lens: Glass
F-5HA Housing: Aluminium
Lens: Glass
Reflective Reflective Reflective Reflective ø3.7
2-ø3.2
lens
ø4.3 ø5 ø4.3 ø5 ø7.4 ø8

5 5 8 5.5
15 12
15.6 9.5 27 10.4
2.4
(Knurled nut attached.) 2.2
5.6
F-6HA Housing: Aluminium Lens: Plastic 8.7

M8 P= 1.0
Reflective 12 A A (A-A cross section view)
26
Chamfering (4.0)
3.5
ø10.6
(M8 nut and washer provided)

With lenses
F-1+FU-7F/86A/86Z F-1+FU-77/77V F-1+FU-77G/77MG F-1+FU-84C/88K
ø4 ø4.2
Thrubeam ø4 Thrubeam ø4 Thrubeam ø4 Thrubeam ø4

6 6 6 6
9.5 12 9.5 11 9.5 12 9.5 15

F-2+FU-7F/86A/86Z F-2+FU-77/77V F-2+FU-77G/77MG F-2+FU-77TG/77MTG


ø4 ø4
Thrubeam ø4 Thrubeam ø4 Thrubeam ø4 Thrubeam
7.9
7
7.9 12 7.9 11 7.9 12 5

F-2+FU-84C/88K F-4+FU-7F F-4+FU-77/77V F-4+FU-77G/77MG


Thrubeam ø4 ø4.2 Thrubeam Thrubeam ø4.3 Thrubeam
ø4.3 ø4.3 ø4

7.9 15 9.5 12 9.5 11


9.5 12

F-4+FU-77TG/77MTG F-5+FU-7F/86A/86Z F-5+FU-77/77V F-5+FU-77G/77MG


Thrubeam ø4.3 Thrubeam Thrubeam Thrubeam
9.5 9.3 9.3 9.3
7 5.3 4.3
16.7 16.7 5.3
5 16.7

42
Fibre Unit
Dimen-
CAD Data Download Service www.keyence.com/cad sions
Diagram

Unit: mm

F-2HA+FU-21X/FU-24X F-2HA+FU-35FA F-2HA+FU-2303 F-2HA+FU-35FZ


Reflective Reflective Reflective Reflective

15.6 15 5 15.6 9 5
15.6 12 15.6 10 5

F-2HA+FU-35TG F-2HA+FU-35TZ F-3HA+FU-35FA F-3HA+FU-2303


Reflective 15.6 13.5 6 Reflective 15.6 9.5 6 Reflective Reflective

9.5 15 5 9.5 10 5

F-3HA+FU-35FZ F-3HA+FU-35TG F-3HA+FU-35TZ F-4HA+FU-35FA


Reflective Reflective 9.5 13.5 6 Reflective 9.5 9.5 6 Reflective

27 15 5
9.5 9 5

F-4HA+FU-2303 F-4HA+FU-35FZ F-4HA+FU-35TG F-4HA+FU-35TZ


Reflective Reflective Reflective 27 13.5 6 Reflective 27 9.5 6

27 9 5
27 9 5

F-5HA+FU-35FA F-5HA+FU-2303 F-5HA+FU-35FZ F-6HA+FU-21X


Reflective Reflective Reflective Reflective
5.4 5.4 5.4
15 L 5 15 L5 15 L 5
26 4
L = 8.6 to 13.5 L = 3.6 to 8.5 L = 2.6 to 7.5 (M8 nut and washer provided)

F-6HA+FU-35FA F-6HA+FU-2303 F-6HA+FU-35FZ F-6HA+FU-35TZ


1.5 6
Reflective Reflective Reflective Reflective

2 1
26 7 5 26 5 26 5 26
(M8 nut and washer provided) (M8 nut and washer provided) (M8 nut and washer provided) (M8 nut and washer provided)

43
1 2 3
STEP 3 Select an amplifier Select a
sensor
type
Select a
specific
sensor
Select an
amplifier

Cable Type Type


Model Control External input Analogue output
NPN output PNP output outputs

Main unit Main unit FS-N11N FS-N11P


Standard 1 0
Expansion unit FS-N12N FS-N12P
0
Main unit FS-N13N FS-N13P
2-output 2 1
Expansion unit FS-N14N FS-N14P
Expansion
unit Analogue Main unit FS-N11MN — 1 0 1

Connector Type Type


Model Control External input Analogue output
NPN output PNP output outputs
(M8)
Main unit Main unit FS-N11CN FS-N11CP
Standard 1 1
Expansion unit FS-N12CN FS-N12CP
0
Main unit — FS-N13CP
2-output 2 0
Expansion
unit Expansion unit — FS-N14CP

Optional (sold separately)


Description Model
Amplifier securing bracket
(for main unit)

Can be installed without a DIN-rail. OP-73880


OP-73880
Can be installed from above or from the side.

End unit
(when using expansion units)
Used to secure the main and expansion units. OP-26751
(Two per set) OP-26751
(Two per set)

M8 connector cable
(2 m/10 m) 2 m type
OP-73864
Used to connect to the M8 connector type amplifier
(model numbers end with a “CN” or “CP”). Connector
cables are not included with the amplifier.
10 m type
OP-73865

Expansion converter unit

The FS-N Series has different amplifier connection connectors than the FS-V30,
LV, and CZ Series. This is an adapter to connect these models. It supplies power
OP-87199
from the main unit to the expansion unit and prevents interference.
*Communication is not supported.

www.keyence.com

Copyright (c) 2009 KEYENCE CORPORATION. All rights reserved. FUGC-WW-C-GB 1067-6 600544