H801MPWD

Connection Power Board Description

Compiled by Thunder-link.com

A leading Professional Huawei GPON Networks Equipment Supplier

HUAWEI TECHNOLOGIES CO., LTD.


Copyright © Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means
without prior written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their
respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between
Huawei and the customer. All or part of the products, services and features described in this
document may not be within the purchase scope or the usage scope. Unless otherwise
specified in the contract, all statements, information, and recommendations in this document
are provided "AS IS" without warranties, guarantees or representations of any kind, either
express or implied.
The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents, but all
statements, information, and recommendations in this document do not constitute a
warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.


Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com

Email: support@huawei.com
H801MPWD Board
Contents
8.11.2 H801MPWD Board

8.11.2 H801MPWD Board


The H801MPWD board is an AC power board, consisting of an AC power
unit and a monitoring unit. The board supplies power to the device
and supports the lead-acid battery for power backup. The AC power
unit provides overcurrent protection, output overvoltage protection,
short circuit protection, and over-temperature protection. The
monitoring unit provides comprehensive management for the power
system and storage battery, and also provides certain environment
monitoring functions.

Feature and Specifications

The H801MPWD board supports the following functions and


specifications:

 Input AC voltage: -100 V to -240 V


 Input AC frequency: 50 Hz to 60 Hz
 Single-phase three-wire AC power input
 Battery port, a 3.3 V terminal socket, supporting DC input
power
 Lead-acid battery input, reverse polarity protection, and fuse
protection
 Output DC power voltage: -48 V (adjustable from -42 V to -57.6
V)
 Rated output power: 400 W
 Alarm monitoring
 Enabling and disabling of the rectifier module; equalized and
float charging for the rectifier module
 Battery low voltage disconnection; charge and discharge
management of storage batteries

Parameters

Please refer to "Power Consumption and Maximum Frame Size of Boards".

Working Principle

Figure 1 Working principle of the H801MPWD board


The basic working principle of the H801MPWD board is as follows:

 AC input power is supplied to the board. After AC/DC conversion,


the power is supplied to the system backplane at -48 V (adjustable).
 The board supports battery input. The monitoring unit manages
the charging and discharging of batteries.
 The board communicates with the system through the backplane,
reporting board hardware and electronic label information to the
backplane.
 The board supports communication with the monitoring unit
through the 485 protocol to adjust voltage and current and report
alarm information.
 The board supplies 3.3 V power from the system to the
monitoring unit.
 The monitoring unit manages lead-acid batteries.
 The optical coupler implements the battery low voltage
disconnection function.
 The board provides power distribution checking and alarm
reporting functions.

Front Panel Ports


Indicator

Indicator Name Status Meaning

AC IN AC input Green: on Indicates that the AC input


indicator power is normal

Off Indicates that the AC input


power is abnormal

DC OUT DC output Green: on Indicates that the DC


indicator output power is normal

Off Indicates that the DC


output power is abnormal

BAT Power input Green: on Indicates that the relay is


Indicator Name Status Meaning

indicator picked up

Off Indicates that the relay


drops out

PMU Running Green: blinks every Indicates that program


status 0.25s loading is in progress
indicator
Green: blinks every 1s Indicates that the board
runs normally

Red: blinks Indicating that the board


is starting up

Red: on Indicates that a critical


alarm is reported

Orange: blinks Indicates that a minor


alarm (such as the high
temperature alarm) is
reported

Parent topic: Power Board (MPW)