1) Check if both blower fans are running ( heat exchanger on roof ) .............
if not check the jumper on PCB board
Airflow direction is to the boom ( up wards ) .............
Check the delta temp between inlet and outlet ( Min 8 –10 ° )
2) Is the compressor running ( check indicator lights on PCB board and power to the
compressor ? ..............
4) Check the four way water valve ( only 2 hoses should be hot ) ..............
6) Check the temperature of the hoses on the roof heat exchanger small ..............
big ..............
(Delta temp should min 8 – 10 °)
A.P. 8/2003 1
Service Training
18 19 20 16 17
5 1
On the PCB board ( right behind the driver seat 9) we have to connections
Com 1 2 cable ( temperature sensor )
Com 2 5 cable water valve connections , on the board you have the cable colour stamped on
1) Check the cable connection ( remember sometimes the extension cable changes colour
without notice )
2) Check if the temp sensor is connected
A.P. 8/2003 2
Service Training
This is a original Eberspächer part number only if required note this on the parts orderform
A.P. 8/2003 3