Sensepoint XCD

Flammable, toxic and


oxygen gas detector for
industrial applications
Sensepoint XCD

One-Stop Shop
• Flammable (catalytic or infrared), toxic
The Sensepoint XCD range provides
and oxygen versions available
• New and retrofit applications
comprehensive monitoring of flammable,
• Suitable for indoor or outdoor use
• Stainless steel or aluminium toxic and Oxygen gas hazards in potentially
explosion-proof housing options
• IP66 as standard explosive atmospheres, both indoors and
Proven and Reliable outdoors. Users can modify detector
Sensor Technology


SurecellTM electrochemical sensors
Poison immune infrared sensors
operation using the LCD and magnet


Poison resistant catalytic bead sensors
Long life sensors
switches without ever needing to open the
Global Approvals unit. This enables one-man, non-intrusive
• US and Latin America, European,
Canadian and Asian operation and reduces routine maintenance
• Compliant with UL, INMETRO, ATEX,
IECEx, CSA, KTL, PA, GB and CCCF time and costs.
standards
A tri-colour backlit LCD clearly indicates the Sensepoint XCD has an integral mounting plate
Easy to Use unit’s status at a glance, even from a distance. for surface mounting or can be mounted to a
• User friendly and intuitive tri-colour A steady green backlight indicates normal horizontal or vertical pipe using the optional
backlit display with digits, bar graph operation, flashing yellow indicates fault and pipe mounting bracket. Electrical installation
and icons flashing red indicates an alarm. can be made using either conduit or cable
• Fully configurable via magnetic switches with suitable mechanical protection. Two M20
• Optional remote sensor mounting* All detectors are supplied pre-configured or ¾”NPT entries are provided (depending
• Selectable sink or source 4-20mA output and include 2 programmable alarm relays, on certification). A weatherproof cap is also
• Auto-inhibit during maintenance 1 programmable fault relay as well as an included for use in the harshest outdoor
• MODBUS communications for remote industry standard 4-20mA output (sink or conditions. Other optional accessories include
diagnostics/configuration* source selectable) and MODBUS*. a sunshade/deluge protection, duct mounting
The scale, range, relay operation, alarm set kit, collecting cone and remote mounting
Cost Effective sensor socket*.
• Common transmitter platform point and electronic tag number of the detector
• Minimal training required can be adjusted using the transmitter's LCD Sensepoint XCD ensures easy installation
• Reduced spares and non-intrusive magnetic switches. Outputs and the fastest routine operation by removing
• Non-intrusive, one-man operation are automatically inhibited during adjustment, the need for hot work permits in hazardous
• Plug-in sensor replacement thereby reducing the risk of false alarm at the areas. Using easy to replace plug-in sensors,
• MODBUS multi drop option offers control panel during maintenance. downtime is also reduced and on-going costs
cabling savings* are minimised through the use of poison
resistant flammable sensors, poison immune
Simple Installation infrared Hydrocarbon sensors and patented
• Plug-in display module removes to give access Surecell™ toxic sensors.
to terminal area 8
• Integral mounting bracket 11
• 2 x M20 or ¾” NPT cable/conduit entries 5
4
(certification dependent)
• Removable plug/socket type terminal blocks for
ease of wiring
• Sink/source switch to suit preferred wiring 10
topology 3
Range of Optional Accessories 2
• Remote sensor mounting kit* 1
• Remote sensor gassing kit
• Duct mounting kit
• Calibration gas flow housing
• Collecting cone
1 Cover
* Contact Honeywell Analytics for availability of these options. 2 Display module
6 3 Terminal area
4 Blanking plug
5 Transmitter
Typical Applications • Refineries and chemical plants 6 Plug-in XCD sensor
• Industrial manufacturing facilities 7
• Onshore oil and gas terminals 7 Sensor retaining ring
• Power plants
• Production platforms 8 Integral mounting plate
• Waste water facilities
• Exploration and drilling 9 Weather protection assembly
• Utilities
• Food and beverage production 9 10 Cable/conduit entry (x2)
11 Certification label
Sensepoint XCD Overview

There are three different types of the XCD


Sensepoint XCD Sensor Families, Gases and Ranges
transmitter for use with three different families
of sensors. User Selectable Default Selectable Cal
Gas Steps Default Cal Point
Full Scale Range Range Gas Range
The mV type transmitter is for use with the Catalytic Bead Sensors
mV family of XCD sensors including catalytic
Flammable 1 to 8* 20.0 to 100.0%LEL 100%LEL 10%LEL 50%LEL
sensors to detect flammable gases in the
range 0-100%LEL and infrared (IR) sensors Infrared Sensors

mV
for detection of Hydrocarbon gases in the Methane 20.0 to 100.0%LEL 100%LEL 10%LEL 50%LEL

Sensor Family
range 0-100%LEL and 0-100%Vol*, as well as Methane 20 to 100%Vol.* 100%Vol. 10%Vol. 50%Vol.
30 to 70% of selected
Carbon Dioxide (CO2) in the range 0-2%Vol. Carbon Dioxide 0.1 to 2%Vol. 2%Vol. 0.1%Vol. full scale range 1%Vol.
The EC type transmitter is for use with Electrochemical Sensors
the EC family of XCD sensors including Hydrogen Sulfide 10.0 to 100.0ppm 50.0ppm 0.1ppm 10ppm
EC

Carbon Monoxide (CO), Hydrogen Sulfide,


Carbon Monoxide 100 to 1,000ppm 300ppm 100ppm 100ppm
(H2S) and Hydrogen (H2).
Hydrogen 1,000ppm only 1,000ppm n/a 500ppm
The Oxygen transmitter is for use with the
O2

Oxygen 25.0%Vol. only 25.0%Vol. n/a 20.9%Vol. (Fixed) 20.9%Vol.


Oxygen (O2) XCD sensors.
A transmitter can auto-recognise any sensor
from within its sensor family. The sensor
simply plugs into the bottom of the transmitter
and the transmitter automatically configures
itself accordingly. mV Transmitter EC Transmitter O2 Transmitter
IR Methane %LEL

IR Methane %Vol*

IR Carbon Dioxide %Vol

Catalytic Flammable 1* to 8* %LEL


(default CH4 0-100%LEL)

EC H2S

EC CO

EC H2

EC O2

Ready, Steady, Go!


Sensepoint XCD uses three instantly
recognisable ‘traffic light’ colours to indicate
its status. The large tri-colour backlit LCD
is steady green to indicate normal operation,
flashes yellow to indicate a fault/warning
and flashes red to indicate an alarm. This
allows anyone in the area to clearly see at a
glance the status of any detector. This can be
particularly useful to identify detector status if
the detector is located in a difficult to access Normal Fault/Warning Alarm
area or if a number of detectors are located in
the same area.
XCD is the right choice for a variety of demanding industrial applications Analytics Serves
Building
Specific Area
Gases Present Every Business
Environment (Detected by XCD)
We offer the industry's most complete
• Raw material storage range of gas detection products and
• Process Areas • General services to meet all customer needs.
• Laboratories Hydrocarbons
Chemical Plants • Pump rows • H2S Commercial
• Compressor stations • NH3 Vulcain-brand gas detection from standalone
• Loading/unloading areas • O2 units to fully engineered, multi-point systems,
all offering cost-effective regulatory compliance
» Applications: parking structures, chillers,
• Exploration drilling rigs • General mechanical rooms, office towers,
• Production platforms Hydrocarbons commercial buildings, shopping centers,
• Onshore oil and • H2S swimming pools, golf courses, schools
Oil & Gas • CO
gas terminals and universities, laboratories
• Refineries • O2
Industrial
Renowned Sieger and Manning gas detection
systems with advanced electrochemical,
• Around the boiler pipework
• Flammable infrared and open path sensing technologies
and burners
• CH4 » Applications: oil and gas, cold storage,
• Turbines
Power Stations • H2 water/wastewater treatment, chemicals,
• Coal silos and conveyor
• O2 engine rooms, plastics and fibers, agriculture,
belt areas in older coal/oil
printing and light industrial
fired stations
Portables
• General Single or multi-gas Lumidor and other premium
• Digesters Hydrocarbons detectors with compact, lightweight designs
Waste Water • Plants sumps • H2S ranging from simple alarm only units to
Treatment Plants • H2S scrubbers • CO advanced, fully configurable and serviceable
• Pumps • O2 instruments
» Applications: underground utility and
electricity ducts, boiler rooms, post-fire sites,
• General sewers, industrial plants, industrial hygiene,
Hydrocarbons first esponder teams, remote fleets
• Incoming gas main • H2S
Boiler Rooms • CO High Tech/Government
• Boiler and gas piping A complete portfolio of gas and chemical
• O2
detection instrumentation including infrared
spectroscopy (MST) with no cross interference,
to Chemcassette paper-based solutions (MDA
• General Scientific) offering detection down to parts
Hydrocarbons per billion
• Laboratories
• H2S » Applications: semiconductor manufacturing
Hospitals • Refrigeration plants
• CO and nanotechnology, aerospace propulsion
• Boiler rooms
• O2 and safety, specialty chemicals industry,
research laboratories, emergency response

Technical Services
24/7 global network includes post-sales service
and Systems Integration teams
» Emergency call out, service contracts, on/
off-site repair, training and commissioning
» Complete range of spares, consumables
and accessories
HWA6181

H_XCD_DS01082_V1_US 5/09
© 2009 Honeywell Analytics

S-ar putea să vă placă și