Sunteți pe pagina 1din 21

EDITORIAL

INSTALLATION

System Requirements The utility installation

Before drawing

COMMANDS

dimensioned
Insertion
Bill
Continuous Drawing Settings
continuous drawing
shooting
starting point
smart copy
smart mirror
Selection
movement
systems
Plane change

special labeling
Exploding
Properties

ELEMENTS

Rectangular ducts, attenuators, controllers


Pipes, fittings, attenuators, controllers
Grids and accessories
Fire dampers, smoke discharge grates
Duct fans
Duct Calorifers
Duct filters
EDITORIAL

Welcome the PanolCAD among users!


The current version features have been made based on your feedback, comments.
Their help thank you!
The program is designed to help engineers design, technical design and drawing rajzolókat of
the duct system.
In this manual you will find detailed instructions on using the program. The program is fast and
easy to use and you will shortly way around it without the manual. It is best if you turn on your
computer screen and execute everything that you read the following pages. If on the use of
software experience problems or have any comments, please indicate:

PANOL Rt.
6641 Szeged, Csongrad road first
Tel: (00-36) 63 / 570-700
Fax: (00-36) 63 / 570-760
E-mail: panolhu@panol.hu

This handbook is based on the AutoCAD design and typographic conventions in this manual.
Those who use AutoCAD, you can use your experience with the software.
Some exceptions to the manual notes (copy, explode).
basic functions and commands from AutoCAD be separated from the technical features
including application software functions and commands. The program assumes the knowledge
of the user from AutoCAD and reference book. AutoCAD commands and functions reference
book documented the PanolCAD reference book is no longer discussed.

I wish you much success in using the software!

INSTALLATION
System Requirements:

The basic software:

 AutoCADR14 or AutoCAD2000

The basic hardware:

 The drawing any computer meets on which the AutoCADR14 or functional


AutoCAD2000

Installing the Utility

The program finds a CD. Copy machine keeping the directory structure of a folder you specify.

The first AutoCAD is loaded on the next steps to be carried out using the program:

 Loading device / Applications directory Loading ... window PanolCAD the panol.arx
 Device / Settings / Support files ... enter the path to the directory path PanolCAD menu

 Device / Settings / Support files ... enter the path PanolCAD / Icon directory path menu

After restarting AutoCAD one more option:

 Device / Menus ... Adjustment window to load the library PanolCAD panol.mns

The next time you start AutoCAD or AutoCAD2000 utility automatically loads itself with the
menu.

Before drawing

After loading two-dimensional architectural floor plan consisting of disposal aspect ratio of M1:
1 from
- mm - needed to adjust.
COMMANDS

dimensioned

The technical elements of the air drawn automatically performs the important dimensions
(Length, width, height, diameter) and in the bill of an identification number signal system.
The cross-sectional dimensions are automatically put the battery connection of the utility, the
length dimensions must be placed in the drawing for you.
The most important elements (grilles, shutters control, fire protection elements) dimensions,
típusjelöléseit, air flow volumes and the identification marks also offers accommodation. I
propose to give the air quantities of these elements, because in their absence, 0 m3 / h in the
identifying inscription.
The inscriptions, dimensions independent of the drawn elements, so it can be deleted afterwards
be moved. These amendments do not change the BOM.
Fire-fighting equipment parameterising window, you should be given an identification number
(control signal), which is included in the bill, note and subtitles as well.

The consignment labels placed on the item or element to within 200mm can not draw a line
utility index.

Escape key to navigate the size disposable and offered the following data.
Q + Enter key to exit full-dimensioning.

The dimensioning can last as drawn, or starts the selected (discussed later command) element
of the program.
The dimensions of the program, the selected color, style, design and size of the signal magnitude
put transparencies defined in the System Properties window.

In this version, the consignment intelligent labels. canceled and subsequently re-numbered
elements dimensioned drawing after the application program. Labels sites, the Move
(AutoCAD) command or by simply selecting it (AutoCAD), followed by the modified label,
showing the extension line.
The lengths can also be moved after AutoCAD's appointment distance from the element can
increase or decrease.
After dimensioned by varying the size of the signal size on the label is modified. So many scale
drawings can be printed immediately.
Different sizes may be different in size transparencies. The film by varying the size and the
inscriptions, the utility asks whether you want to keep with the old film sizes. Thus, the films
off and on easily print multiple scale of the drawing.
Insertion

This function allows you to insert a third element between the two elements drawn.
Insertion elements: VL 01, VL 05, VL 08, VL 10, SPIKO tube, Flex tube Insulated pipes and
silencers (tubes and rectangular elements).
After you click Insert two elements to be shown. After that, the inserted item to be selected,
then the program - inserts the selected item - if possible. It is not possible, for example, 6000mm
and insulated tube inserted SPIKO because the maximum length of 3000mm production.
In that case, I recommend using this feature if you know exactly the location of two elements
(Trunk - fitting for receiving a cell állmennyezeti grille box, before looping concealed elbow)
and insert the item would be difficult parametrizálni.
Tubes, the straight duct when inserting the male element, the continuous drawing
settingsdivide lengths in the set.
Bill

made per system BOM!


The list produced contains the following information:
- number (First column) - which will be the order of creation of the item
- Quantity (second column) - get the same type of components and parameters same sequence
number within a system
- type of signal (the third column, consistent with catalog)
- Font size marked (In the same following columns catalog)
- comment (You're typing)
These parameters define precisely the elements.
Text files can be edited in Excel and can be saved to any version.
If you send the Panola Rt. E-mail address in the text file, it is priced, beszerkesztve, calculated
square meters will be returned.

The program automatically stores each item. THEHowever Properties (discussed later
command) window can be removed (ex post) on any item in the list.
It is necessary for the engravings, views when drawing. There will be elements that need to be
drawn more than once or twice, but only be included in the bill of time.
The item categories are not found in pipe fittings and switches. These items will automatically
appear at the end of the BOM.
Continuous Drawing Settings

Before using the continuous drawing of settings required to perform.


The default setting will automatically divide the straight sections.
The default setting in the manufacture and supply of components more economical.
The value set here is a benchmark for the Insert function. These shares lengths of inserted
batteries.
VLE 01 and VLE-02 01-VFE vertical sections divide the set point values in the utility.
continuous drawing

The function has to be determined by means of a drawn element (optional section) is "only" a
trail of ductwork, build and program the system, divided into sections for straight lengths
specified in the continuous drawing settings.
The program shows the direction and length of the straight section of an auxiliary line (starting
from the end of the existing elements).
The commands can be selected and rotated parametrizálni arbitrary shapes without leaving.
Escape key may be suspended only in the command. To exit, you must click the shortcut again.
The pipes in pipe nipples (VF-01), profiles include idomkapcsolókat (VF-02) stores the piece
of list utility.

shooting

The last item selected or drawn on the Select command (discussed later) Rotating the screen
plane. Repeated clicks of the rotating element.
starting point

you have to show the drawing area, the position and orientation of the first item after the
starting point you click. Then, the starting point box appears automatically.
Systems ... the first step to be determined. After clicking the button to select the System
window will appear. In this window, existing or new systems ... are available. You may be
modified or deleted legacy systems.
New… Clicking can be defined in detail in the System Properties window.
The system properties except for sign of all the parameters can be changed retrospectively
systems Select the icon by clicking Edit Window System ... command.

The adjustable System Properties window parameters are:

sign: You can be four characters. subsequent azorequired recycled and


which is visible on each item parameterising window. required per
system BOM-making. You can not subsequently be changed.

Signal Size: Inscriptions, size dimensions.

name: Short description of the system.

Dimensions and texts: st set in AutoCAD and can be selected hereusok.

Foil: Automatically separate foil (Propanol - a sign system - signal size)


Are the elements which can be modified. Modifying the signal size
and dimensions of the new film will be a modified layer.
THEz given element can be unloaded onto any AutoCAD Properties
feature film. The ceiling rácskiosztás required for printing.
Numbering
The initial value: The first element is the number that is listed on the bill of consignment
and the label itself. And multi-storey buildings stored in a separate file
when drawing PMenergy required to be continuous numbering of the
BOM.

Marking laps: The consignment labels (System sign / Serial) highlighting or without
round circle drawable.

Inscriptions frame: highlighting subtitles (type / size / volume flow rate) frame vaDraws
are no ring frame.

Line Type: Any AutoCAD line type, film and color can be selected.
Draw lines or in the medium without the distinguishing elements of
the circle and a square connection.

The system indicated except for all the properties of the films be made.
The properties were then select System System Adopted window comes back to the departure
point window where the air ducts and the air flow parameters to be determined.
diameter chosen arbitrary rectangular cross-section and size to be initiated line drawing.
Typing the air quantity of the utility information air velocity in the current cross section.
There is no speed limit built into the air, and even operate the air volumes in the absence of
features.
smart copy

Existing elements can be copied like to use AutoCAD commands.


Do not be fooled by the designer colleagues that the bill of copying features in AutoCAD can
increase the number of items, but can cause problems later on.
This version has the ability to cut and paste between systems. After selecting the elements of
the utility asks for the selected items, the new system is selected, the selection of the System
window appears where you can define the details.

smart mirror

AutoCAD and mirroring using some parameters can not be dimensioned in the right place,
these problems eliminating the use of the utility function.
The mirror elements can be drawn like to use AutoCAD commands.
The bill of the number of elements increases, of course.
Within the current system mirroring between systems and possible new system is selected, the
selection of the System window appears where you can define the details.
After selecting the elements you will be asked to reflect on the plane.

Selection

you have to show an item after clicking on the icon, which I want to change the properties or
wish to continue drawing from the element. If output is available for the selected item, the
utility adjusts the next item.
The selected item is highlighted, like AutoCAD dotted lines.

movement

possible movement of the item to be drawn between the free ends of the existing element (eg.
03-VL).
Repeated clicks the movable element.
systems

for subsequent amendments to the defined starting point of the menu system properties.
The signal system can not be changed afterwards!
When you change the film elements are drawn in the new film only after the change.

Plane change

The current element is rotatable perpendicular to the plane of the screen plane. Repeated
clicks of the rotating element.

special labeling

subsequent labeling of certain items is intended to function. These items do not get a sign
dimensioned. Selected items will be presented to the inscription of the site plan, which
includes the amount of air flow, air speed and program directly from the air flow direction
arrow.
These elements are: VL 01, VL 11, VL-11k, SPIKO pipe, flexible pipe, flexible pipe SPIKO
and attenuators.
Exploding

This feature pruning two elements necessary to delete lines not shown.
Selected an item directly from the program, which put the original film elements.
This is because the bill will search for items and stores the items listed in this film is taken.
Then, the battery exploded AutoCAD functions can be used in the wipeout.
AutoCAD explode when using pieces are removed from the list of elements blew up!

Properties

The icon on the current element parameterising window appears click, which determine the
exact elements required for all entries.
The profile catalog number, the item type signal and the system can be seen in the window.
The connecting dimensions are displayed for information purposes, the missing information
must be completed. The element parameters displayed on the small figure.
Rectangular elements of any size is accepted by the program, in case of circuit connection can
choose the size of the diameter line.
The amounts of air entering each cross-checked, the air velocity can be designed. No limits
(lower, upper) incorporated.
The comment you have entered line (eg. the grid custom color, material quality) are included
in the bill of course as well.
All drawn items on the BOM. Views, sections draw upon more than once drawn the items to
be removed from the list in one view, it should be included only once in a BOM.
The air velocity, note, bill of materials properties and options can be modified retroactively.
ELEMENTS

Rectangular ducts, attenuators, controllers

In this chapter, only different katalógustól marked items requiring a peculiar way of drawing
discussed.

UF-17, LEM, S 15 NT 29 NT 28

designation of the item, the actuator can be seen. These elements can be built only on the
horizontal lamellas. You have to shoot the right side (knowing that draw over or side view) a
"small box" while the program rotates the width and height dimensions of the BOM.

VLE-03 VLE-04, 05-VLE

These unique items that are frequently used, but not listed in the catalog.
The program includes elements dwg files of this extension, you changed the dimensions of
the hozzáfűzhesse BOM.
VL 02, VL-07, H-SG, SG-V

The screen is swiveled plane elements no free access points, the phase will not be continued.
perpendicular to the plane of the screen sections solved the VL element 10 or 01 and the VLE
VLE 02 elements. The former type batteries element (VL + VL 02 ill.07 01) are enrolled in
the BOM.

Pipes, fittings, attenuators, controllers

In this chapter, only different elements katalógustól labeled in need of special drawing mode
is discussed.

Flex tube

Continuing the drawn air duct section of the pipe track must be determined, and the program
builds the (tube inserted in the center line of the trail) system. In reality, it applies a bend
radius of not greater radius defined trail.
The pipe line type ZIGZAG, distinguishing the SPIKO tube.

VF-04, VF-05,

The screen is swiveled plane elements no free access points, the phase will not be continued.
perpendicular to the plane of the screen sections solved by the VFE-01 elements. The
foregoing elements are enrolled in the BOM type element (VF-04 + pipe SPIKO).
Grids and accessories
In this chapter, only different elements katalógustól labeled in need of special drawing mode
is discussed.

EV, DRC

The program in each case (top and side views as well) to draw the weather protection grilles
outwardly sloping lamellas. you need to check the properties icon B (width) and H (height)
dimensions are correct parameterising window, the sal-Plane change these dimensions can be
replaced.

Air grates and boxes

The only program diameter pipe, fittings more suitable for recording the most connections in
the grid box provider does not allow to connect. Any grid box and connected to the nipple
diameter to the type below this size. Besides the dimensions of the grids of the type brackets
merge stub in diameter.
Fire dampers, smoke discharge grates

In this chapter, only different elements katalógustól labeled in need of special drawing mode
is discussed.

XN, LZ3

Marking of the battery in the control box can be seen. You will have the Síkváltással rotate
the item in the right position, you can check the status of the control box.

BOM identification:
- voltage release: IK
- release tension breaking resolution: AK
- Thermal release: TK
- Micro-switch in the open position: MK open
- Micro-switch is closed: MK closed
- Micro Switch open and closed position: MK open and closed
- Electromagnetic release: WEDGE
- servo Motor SM

The fire protection elements made of two or numbering. create the program.
The numbering is done automatically created like any other item.
different from the previous identity number used in the design of fire protection systems. This
symbol can be optionally included in the inscription on the box and at the parameterising
dimensioned.

Duct fans
Like the other elements optional. The parameterising window type is also determined.
Any size can be drawn.

Duct Calorifers

Like the other elements optional. The parameterising window type is also determined.
Any size can be drawn.
Duct filters

Like the other elements optional. The parameterising window type is also determined.
Any size can be drawn.

S-ar putea să vă placă și