Frist Floor
Bed room - 1
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Bed room - 2
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Bed room - 3
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Bed room - 4
Wash Basin 1 0.6
WC 1 2.3
Bath tub 1 1.1
Master Bed room
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Bath tub 1 1.1
Lts/second
50% Usage factor (lts/sec)
VILLA - B
Total Flow in Lts/sec Ground Floor No. Fixtures
1.8 Kitchen Sink 1
0.7 Dish Washer 1
0.7 Washing Machine 1
Maid room
0.6 Wash Basin 1
2.3 WC 1
0.1 Shower 1
Driver room
0.6 Wash Basin 1
2.3 WC 1
0.1 Shower 1
Guest Bed
0.6 Wash Basin 1
2.3 WC 1
0.1 Shower 1
Majils
1.8 Wash Basin 3
2.3 WC 1
First Floor
Bed room - 1
0.6 Wash Basin 1
2.3 WC 1
0.1 Shower 1
Bed room - 2
0.6 Wash Basin 1
2.3 WC 1
0.1 Shower 1
Pantry sink 1
0.6 Bed room - 3
2.3 Wash Basin 1
0.1 WC 1
Shower 1
0.6 Master Bed room
2.3 Wash Basin 2
1.1 WC 1
Shower 1
0.6 Bath tub 1
2.3
0.1
1.1
33.4
16.70
VILLA - B
Flow Rate in Lts/sec Total Flow in Lts/sec Ground Floor
0.9 0.9 Kitchen Sink
0.7 0.7 Dish Washer
0.7 0.7 Washing Machine
Maid room
0.6 0.6 Wash Basin
2.3 2.3 WC
0.1 0.1 Shower
Driver room
0.6 0.6 Wash Basin
2.3 2.3 WC
0.1 0.1 Shower
Guest Bed
0.6 0.6 Wash Basin
2.3 2.3 WC
0.1 0.1 Shower
Majils
0.6 1.8 Wash Basin
2.3 2.3 WC
First Floor
Bed room - 1
0.6 0.6 Wash Basin
2.3 2.3 WC
0.1 0.1 Shower
Bed room - 2
0.6 0.6 Wash Basin
2.3 2.3 WC
0.1 0.1 Bath tub
0.9 0.9 Master Bed room
Wash Basin
0.6 0.6 WC
2.3 2.3 Shower
0.1 0.1 Bath tub
0.6 1.2
2.3 2.3
0.1 0.1
1.1 1.1
Lts/second 30
50% Usage factor (lts/sec) 15.00
VILLA - C
No. Fixtures Flow Rate in Lts/sec Total Flow in Lts/sec
1 0.9 0.9
1 0.7 0.7
1 0.7 0.7
1 0.6 0.6
1 2.3 2.3
1 0.1 0.1
1 0.6 0.6
1 2.3 2.3
1 0.1 0.1
1 0.6 0.6
1 2.3 2.3
1 0.1 0.1
3 0.6 1.8
1 2.3 2.3
1 0.6 0.6
1 2.3 2.3
1 0.1 0.1
1 0.6 0.6
1 2.3 2.3
1 1.1 1.1
2 0.6 1.2
1 2.3 2.3
1 0.1 0.1
1 1.1 1.1
Lts/second 27.1
50% Usage factor (lts/sec) 13.55
VILLA - D
Ground Floor No. Fixtures Flow Rate in Lts/sec Total Flow in Lts/sec
Kitchen Sink 2 0.9 1.8
Dish Washer 1 0.7 0.7
Washing Machine 1 0.7 0.7
Maid room
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
Shower 1 0.1 0.1
Lobby
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
First Floor
Bed room - 1
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
Shower 1 0.1 0.1
Bed room - 2
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
Bath tub 1 1.1 1.1
Master Bed room
Wash Basin 2 0.6 1.2
WC 1 2.3 2.3
Shower 1 0.1 0.1
Bath tub 1 1.1 1.1
Lts/second 20.8
50% Usage factor (lts/sec) 10.40
VILLA - E
Ground Floor No. Fixtures Flow Rate in Lts/sec Total Flow in Lts/sec
Kitchen Sink 1 0.9 0.9
Dish Washer 1 0.7 0.7
Washing Machine 1 0.7 0.7
Maid room
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
Shower 1 0.1 0.1
Lobby
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
First Floor
Bed room - 1
Wash Basin 1 0.6 0.6
WC 1 2.3 2.3
Shower 1 0.1 0.1
Master Bed room
Wash Basin 2 0.6 1.2
WC 1 2.3 2.3
Shower 1 0.1 0.1
Bath tub 1 1.1 1.1
Lts/second 15.9
50% Usage factor (lts/sec) 7.95
VILLA - E
Ground Floor No. Fixtures Flow Rate in Lts/sec
Kitchen Sink 1 0.9
Dish Washer 1 0.7
Washing Machine 1 0.7
Maid room
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Lobby
Wash Basin 1 0.6
WC 1 2.3
First Floor
Bed room - 1
Wash Basin 1 0.6
WC 1 2.3
Shower 1 0.1
Master Bed room
Wash Basin 2 0.6
WC 1 2.3
Shower 1 0.1
Bath tub 1 1.1
Lts/second
50% Usage factor (lts/sec)
No. of villas in one cluster
Total flow from 6no. Villas
At 75% Diversity Factor
Total Flow in Lts/sec
0.9
0.7
0.7
0.6
2.3
0.1
0.6
2.3
0.6
2.3
0.1
1.2
2.3
0.1
1.1
15.9
7.95 Per E type Villa
6
48
36 Lts per sec
VILLA - B
Ground Floor No. Fixtures Flow Rate in Lts/sec
Kitchen Sink 145 0.9
Dish Washer 145 0.7
Washing Machine 143 0.7
Maid room
Wash Basin 346 0.6
WC 346 2.3
Shower 197 0.1
Lts/second
50% Usage factor
No. of villas in one cluster
Total flow from 3no. Villas
At 75% Diversity Factor
Total Flow in Lts/sec
130.5
101.5
100.1
207.6
795.8
19.7
1355.2
677.60 Lts per sec
0
0 Lts per sec
SEWAGE LIFTING PUMPS - TECHNICAL COMPARISION
Sl.No Flygt Concertor Grundfos - AutoAdapt
The control system automatically adapts to the Automatically adapts to the conditions in the sump,