1) Fine and Coarse aggregate grading tests to British Standard.
2) Modified ASTM C29 (or British standard equivalent) test to determine void content for the following: a. Combined Coarse aggregate, Fine aggregate for four different ratios listed in the table below:
Test No Coarse Aggregate Fine Aggregate
1 50% 50% 2 60% 40% 3 65% 35% 4 70% 30%
3) Concrete mix design for 3 different ratios of volume of cement paste /
volume of voids (calculated above). Cement content determined using tables provided by British Standards.