Sunteți pe pagina 1din 4

This file calculates whether the settlement of a footing is suitable using the Schmertmann method

Design requirements
Δ_lim 0.02 m Settlement limit

Material properties
γ_conc 23.5 kN/m3
γ_Dry 19 kN/m3

soil_qc [MPa] 6
E_s [kPa] 18000

Foundation sizes
B 2.7 m Foundation width
D 0.8 m Foundation depth

Loads
P_col 1200 kN Load from the column
P_f 137.052 kN conservatively assume full depth is concrete
P_total 1337.052 kN Total applied load to the soil
p= 183.41 kPa applied pressure

Soil pressures
σ_v0,ef 15.2 kPa
σ_vp,ef 40.85 kPa efective stress @ 0.5B
δq 168.21 kPa

Schmertmann factors
I_zp 0.7029 Peak vertical strain influence factor
C_1 0.9548 Embedment correction
C_2 1 Creep factor (assume immediate settlement only)
C_3 1 Shape factor
Settlement calculations
I_z,init 0.1 -
δz_1 1.35 m Thickness of section 1
k_1 3.0109567E-05 up to peak (0 - 0.5B)
δz_2 4.05 m Thickness of section 2
k_2 7.90787E-05 consider influence depth up to 2B below footing
k_tot 0.0001091883
Δ_estimated 0.0175 m Estimated settlement

Checks
Performance:Satisfied
check: depths 0 Check thicknesses add to 2B
ble using the Schmertmann method

Adjust this until suitable level of settlement is obtained

me full depth is concrete

influence factor

me immediate settlement only)


Ref: (Schmertmann 1970)

depth up to 2B below footing