C - 1A C - 2A C - 3A C - 4A C - 5A C - 6A C - 7A C - 8A
MACHINE ROOM FLOOR TO
LOWER ROOF DECK TO
SIZE = 500mm x 900mm SIZE = 500mm x 700mm SIZE = 500mm x 1150mm SIZE = 600mm x 600mm SIZE = 500mm x 700mm SIZE = 200mm x 500mm
VERT. BARS = 20 - 28mmØ VERT. BARS = 16 - 28mmØ VERT. BARS = 16 - 28mmØ VERT. BARS = 16 - 25mmØ VERT. BARS = 16 - 28mmØ VERT. BARS = 8 - 20mmØ
TIES = 4 - 10mmØ PER SET TIES = 3 - 10mmØ PER SET TIES = 3 - 10mmØ PER SET TIES = 3 - 10mmØ PER SET TIES = 3 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
13TH TO 14TH TO
15TH FLOOR
SIZE = 500mm x 1000mm SIZE = 500mm x 800mm SIZE = 500mm x 1150mm SIZE = 600mm x 600mm SIZE = 200mm x 500mm
VERT. BARS = 24 - 28mmØ VERT. BARS = 20 - 28mmØ VERT. BARS = 20 - 28mmØ VERT. BARS = 20 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 4 - 10mmØ PER SET TIES = 4 - 10mmØ PER SET TIES = 4 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
11TH TO 12TH TO
13TH FLOOR
SIZE = 500mm x 1200mm SIZE = 500mm x 900mm SIZE = 500mm x 1150mm SIZE = 700mm x 700mm SIZE = 200mm x 500mm
VERT. BARS = 26 - 28mmØ VERT. BARS = 24 - 28mmØ VERT. BARS = 22 - 28mmØ VERT. BARS = 24 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 5 - 10mmØ PER SET TIES = 4 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
9TH TO 10TH TO
11TH FLOOR
SIZE = 500mm x 1300mm SIZE = 500mm x 1000mm SIZE = 500mm x 1150mm SIZE = 700mm x 700mm SIZE = 200mm x 500mm
VERT. BARS = 30 - 28mmØ VERT. BARS = 28 - 28mmØ VERT. BARS = 24 - 28mmØ VERT. BARS = 28 - 25mmØ VERT. BARS = 8 - 20mmØ
TIES = 6 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 4 - 10mmØ PER SET TIES = 5 - 10mmØ PER SET TIES = 2 - 10mmØ PER SET
GENERAL CONTRACTOR:
16-STOREY OFFICE BUILDING
ASEC DEVELOPMENT AND
22
CONSTRUCTION CORPORATION
GENERAL BUILDING CONTRACTOR ENRISON HOLDINGS INC. AS - BUILT PLAN S
Tower A-3rd Floor, Regalia Park, 150 P. Tuazon
Avenue, Cubao, Quezon City 1109
30