Installation manual
Status RELEASED
Contents
Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.1 Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.1 Rack Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.1.2 Weight and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2 Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.3 Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.4 Initial State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.5 Final State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.6 Operating Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.7 Time Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.8 Information Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.1 Before Leaving for the Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2.2 Before Starting (On Arrival at the Site) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3 Installing the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.1 Rack Transportation on Final Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2 Rack Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3 Reversing the Rack Door (If Necessary On Site) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.4 Positioning the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.5 OPTION: Fixing on Concrete Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.5.1 Drilling the Concrete Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.5.2 Fixing to the Concrete Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.6 OPTION : Fixing to the Raised Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.6.1 Drilling the Raised Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.6.2 Fixing to the Raised Floor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.7 OPTION : Fixing to the Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.7.1 Wall Drilling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
3.7.2 Fixing to the Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.8 Preparing the Site Cable Tray and the Metal Sheath . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4 Installing the Power Supply Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
4.1 General Cabling View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4.2 Installing the Cables in the Cable Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.3 Protective Earth Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.4 Rack Side Power Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.5 Site Side Power Cable Connections (48 V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4.6 Power Supply Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5 Installing the PCM Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5.1 Installing Cable in Cable Tray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.2 Rack Side Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.2.1 Prepare the PCM Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.2.2 Connect the Cables to the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.2.3 L907/ 4 120 - Ohm Cable (Alcatel Kits) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.2.4 FLEX3 / 4 - 75 Ohm Coaxial Cable (Alcatel Kits) . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6 Installing the Antenna Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.1 Antenna General Scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
6.2 Connection to the Feeder Terminaton . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.3 Connection to the BTS Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
7 Installing the Alarm Cables (Options) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
7.1 Installing the Cables (Option) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
7.2 Rack Side Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Preface
Purpose This document describes how to Install on site an Evolium® DC indoor A9100
BTS of the ALCATEL BSS.
Installers
Site administrators
Supervisors
Project managers
Occasional users.
History
Date Edition Comments
000211 01 Creation
1 General Information
This chapter provides general information on the principles of the operation and
the requirements of the procedure:
Hardware description
Prerequisites
Restrictions
Initial state
Final state
Task sequences
Time schedule
Information required.
Connection Area
Radio subrack
Radio subrack
DUMMY PANEL
Radio subrack
Connection Area
FAN FAN FAN
DUMMY PANEL
Radio subrack
Radio subrack
Figure 1: Example of Mini DC Indoor A9100 BTS (Left) and Medi DC A9100 BTS (Right)
Mini Medi
Dimensions - -
Width 600 mm 600 mm
Depth 450 mm 450 mm
Height (with 20 mm adjustable feet) 915 mm 1940 mm
BATS 14 kg BATS 14 kg
1.2 Restrictions
None.
1.3 Prerequisites
The site must comply with the ” Safety rules ” of the General Wiring
Handbook ”
The site must be ready to receive the racks, according to SPP 34
Antennas
Antenna
PCM + alarm cables jumpers
1234
1234
1
11
11 Metal sheath
TX
123
112
12
122
RX
123
Earth plate
Alarm
DDF
V A
Finish installation
Unwrapping packages
General checks
Rack preparation
PCM cables
PCM cables
Antenna cables
PCM cables
Antenna cables
Finishing installation 60 60
BTS Rack
Type of BTS rack to be installed (MINI, MEDI)
Kits
Synchronization configuration.
2 Preliminary Checks
At base
Check that the prerequisites are satisfied See Prerequisites (Section 1.3) .
Check availability of tools See List of Necessary Tools (in appendix C), refer to the
” Tools catalogue ” for content checking.
Check applicable notification list and Refer to ITL “Applicable notifications list” for checking if
Operation Instructions notifications have to applied during the operation.
Refer to IO “Applicable operation instructions list” for
checking if operation instructions have to applied.
Check that safety instructions are applied Refer to “ General Wiring Handbook “ for checking that
safety precautions have been taken into accordance with
safety instructions.
Read instructions to be applied in case of Refer to “ General Wiring Handbook “ for instructions.
anomaly
Fulfill premises inspection form and Refer to CEL “ Premises inspection form “.
completion check list
Complete the header field of the CCL
The CCL is completed as each installation instruction is
carried out.
Check availability of Alcatel kits See Installation Kits (in appendix B).
Figure 5: Craning Set OUT 008 3BK 25539 AA ( The Two Sackles Must Be
Passed Through Top Front Side Holes in the MBI )
The BTS door is factory-fitted on the right (i. e. the door opens from left to right).
1
3
2 4
Figure 6: Reversing Rack Door. Door Closing From the Left or From the Right
Procedure 1. Remove the door (1) with its hinges (2) (See Figure 6)
2. Remove the two bars (4), (6) and the part (3)
3. Reverse the latch (5) and fix the two bars (4), (6) in the right place
4. Fix the door to the left side of the rack
5. Connect the earth link to the door and to the top left of the rack
6. Remove the reversed labelling (no Alcatel labels) (See Figure 6)
7. Remove the orange line label.
1234567
1234567
12345671
111
12345
Figure 7: Fit the Feet and Level the Rack
Procedure 1. According to Information Required (Section 1.8) , mark out the rack’s
position on the floor
2. Position the rack
3. Adjust the height of the feet with a 20 mm open-ended wrench
4. Level the rack.
The two holes in the centre of the template are used only for earthquake fixing.
1234
1234
1234 1234567890
1234
1234567890123
1234
123
1234
1234
1234
1234567890123
1234
1234567890
1234567890123
1234567890
1234567890123
1234567890
1234567890123
1234567890
1234567890123
1234567890
1234567890123
Figure 10: Raised Floor
12345678901234567890
12345678901234567890
12345678901234567890
2
12345678901234567890
3 1212 12
12345678901234567890
12345678901234567890
1234
12341234567890 12
123456789012345678901234
1234567890
1234
1234123456789012345678901234
4
5 7
6 8
1212
1234567890123 1234567890123
1234567890123
121
11234
1
12
11
12345
12345 23
2
1 12
2
1
123 1234567890123
11234
1211
2234
1123
123412232
9 123
123 12
12 80
123
123 12
12312
123412
Figure 12: Fixing to the Raised Floor
Procedure 1. Insert the expanding plug 9 in the concrete floor (See Figure 12)
2. Screw in threaded rod 6 with washer 8 and nut 7
3. Screw coupling nut 5 as the figure shows
4. Screw in screw 1 with washer 2
5. Position bracket 3.
123456789012345678901
123456789012345678901
123456789012345678901
123456789012345678901
2
123456789012345678901
123456789012345678901 1
123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456
1234567890123456 123456789012345678901
123456789012345678901
1234567890123456
1234567890123456 123456789012345678901
123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456 123456789012345678901
1234567890123456
1234567890123456 3 123456789012345678901
123456789012345678901 4
1234567890123456 123456789012345678901
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890
12345678901234567890 1234567890123456789012
1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890
12345678901234567890 1234567890123456789012
1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 1234567890123456789012
12345678901234567890 5 1234567890123456789012 6
12345678901234567890 1234567890123456789012
This procedure can be applied if there is no access to the sides of the BTS.
Procedure 1. Fix the two front feet of the equipment with brackets as described for
concrete floor (See Figure 13)
2. Fix the BTS to the wall by the two holes (1) at the top of the rack.
3.8 Preparing the Site Cable Tray and the Metal Sheath
Procedure 1. Make a cut-out in the cable way for the cables with metal sheath (See
Figure 14)
2. Make a cut-out in the cable way for the antenna jumpers
3. Edge the cut-outs with edge protection
4. Fix provisory the metal sheath to the cable way (See Figure 15).
Before making any electrical connections to the BTS, ensure that the safety
instructions are followed.
It is essential that:
123456
123
1234
12345
123
1234
12345
123456
123
1234
12345
123456
123
1234
12345
123456
123
1234
12345
123456
Figure 16: Example of Cabling With Options (Alarm, Synchronization, External Batteries)
1 2
1m
3 4
GND : ∅ 8 mm
BAT A : ∅ 6 mm
BAT B : ∅ 6 mm
BATRET : 6 mm
1
1
3
4
3 Rubber sleeves -
Procedure 1. Prepare the metal sheath and fix it temporary to the cable way with a cable tie
2. Pass the GND cable through the metal sheath
3. Crimp an M8 wire terminal on the GND cable
4. Fit a rubber sleeve on the wire terminal
5. Connect the GND cable to the stud of the BTS (See Step 2)
6. At the site side, cut the cable and crimp a wire terminal on the GND cable
(diameter depending on site) (See Step 3)
7. Fit a rubber sleeveon the wire terminal
8. Connect the GND cable to the site earth plate (See Step 6).
6
(black)
1
2
−48V 0V
3
4
3 Rubber sleeves -
Procedure 1. On the site side, cut the 48 V cables and crimp on a lug (diameter depending
on site)
2. Fit a rubber sleeve on the terminal lug
3. Connect the 48 V cable to the site breakers
4. Label the 48 V cables and the site power box.
Procedure 1. Check that all the rack breakers are switched off
2. At the rack, test for short circuit between 0 V and - 48 V
3. At power box, switch on the fuse breakers (See Figure 20)
4. At the rack, test the voltage polarity (See Figure 20)
5. At the power box, switch off the fuse breakers.
To install and connect the site DDF and terminal blocks, see ” Installation
method for BSS equipment “.
1
2
s2
Abi
1
Abis
3 4
Procedure 1. Refer to Information Required (Section 1.8) for the number of PCM cables
to install
2. Perform steps 1 to 4.
PCM Power
cables cables
Stripped
−48V 0V
Procedure 1. Remove 2 cm of outer insulation near the metal sheath fixing point on
each PCM cable (See Figure 21)
(the specific tie wrap with metallic part will be fixed during sheath fixing at
the end of this document)
2. Prepare the cable termination
(See document ” Installation method of DDF for BSS equipment”)
3. Fit a rubber sleeve (4) (See Figure 22)
4. Label the cables (See Figure 22).
4 Rubber sleeve -
6 5
3
12
1212
1212
12112
12
12
12
12
12
121
12
12
112
12
12
12
12
12
12
12
2
Figure 22: Example With L907 / 4 120 Ohm Cable (Abis1 and Abis2 in the
Same Cable)
123456
12345
12345 123456
12345
12345
12345
1234567890123
12345
12345678
123456
12345
12345678
1234567890123
12345678901234
12345
123456
12345
1234567890123
12345678901234
12345
123456
12345
12345
12345678901234
12345
12345
12345
12345
12345
12345
Figure 23: Adhesive Tie Block for Cable Tie
violet 6 Abis2/ TX
violet 5 Abis2/ RX
B M
L
123
123
123 10 mm
D L9 07
1 AC 0 1 3 2 8 0 0 0 4
100 mm
E
G
A : String
B : Cable drain (GND)
D : Cable
E : Cable braid
F : Transparent film
G : Aluminium foil
Figure 24: L907 / 4 Cable and Preparing Cable Termination
2. Insert the wires in the terminal block (1 in Figure 22)(to avoid cutting
problems os short circuits, take the wire with the first hand and insert it
with the other hand)
3. Fit the lightning protection block
4. Tie the cables to the rack (with adhesive tie blocks).
ABIS 1 TX Coaxial 1
ABIS 2 TX Coaxial 2
ABIS 1 TX Coaxial 3
ABIS 2 TX Coaxial 4
7 8
RX TX
KRONE
1 11
connector
11
11 11
11
Abis 1
Figure 25: 75 Ohm Cable Wiring
This chapter describes how to connect the antenna jumpers between feedeers
and BTS rack.
Ant A
Ant B
Ant A 90
Ant B
Ant B
Ant A
230
A B A B A B
Label:
ANT B
AZIMUTH
125
Label:
SECT: N
ANT A A B A B A B
A A A
B B B
N P Q
ANX ANX ANX
MBS
Figure 27: Example of Coaxial Cabling and Labelling, System With Three Sectors
Feeder Jumper
Q : antenna A N : antenna A
Q : antenna B N : antenna B
not used P : antenna A
not used P : antenna B
Procedure 1. Lead the jumpers through the cut-outs in the cable tray
2. Ensure that hte bending radius of each cable is at least 3 cm
3. Use the plastic ties to bundle the cables together
4. Tighten with special tightening tool (See Tools catalogue).
To install and connect site DFF and terminal blocks, see ” Installation method of
DDF for BSS equipment “.
1m
1
2
m
Alar
8
1−
3 4
Inputs
Outputs
2
1 2 3 4 5 6 7 8
4
Figure 32: Connection Area of the Rack
X GND
X GND
X GND
X GND
X GND
X GND
X GND
X GND
XI8
XI6
XI4
XI7
XI2
XI3
XI5
XI1
QUARTE 1 1 2 2 3 3 4 4
PAIR 1 2 3 4 5 6 7 8
Figure 33: Detail of Input Alarm Terminal Block (Example Alarm 1 to 8
Connector)
Procedure 1. Refer to Information Required (Section 1.8) in chapter 1 for the cable
connections and the quantity of alarms to be connected
2. From the end of the sheathing, bundle the cables together and attach
them with cable ties
3. Fit a rubber sleeve on wire terminations
4. Insert the wires into the connectors:
This chapter describes how to install and connect the synchronization cables
between the new rack and other BTSs on site (option).
2 x SCM x/3 G3
G1 in1
in/out 2
Slave
Master
2 x SCM x/3 in1 G3
in/out 2
Slave
Figure 34: G1 BTS Master - A9100 BTS Slave
2 x SCG2/3 G3
G2 in1
in/out 2
Slave
Master
G3
2 x SCG2/3 in1
in/out 2
Slave
Figure 35: G2 BTS Master - A9100 BTS Slave
G3 SCG3 G3
out 1 in1
in/out 2 in/out 2
Master Slave
Figure 36: A9100 BTS Master - A9100 BTS Slave in Star Configuration
G3 SCG3 G3
out 1 in1
in/out 2 in/out 2
Master Slave
Figure 37: A9100 BTS Master - A9100 BTS Slave in Daisychain Configuration
8.2 Installation
1 2 3 4 5 6 7 8
1 2 3
9 Finishing Installation
12345
1234
12345
1234
12345
1234
123
123
123
123
123
Metallic sheath
123
123
Figure 39: Metallic Sheath Connection (To Upper CableTray)
Metallic sheath
Metallic sheath
Tie wrap
Washer O 8
metallic
Hex nut M8 Cables (stripped 2 cm)
Power cables
(not stripped)
Screw HM 8x14
Figure 40: Metallic Sheath Connection to the Rack and Stripped Cables Fixation
2 Wire terminal -
5 Washer ∅ 8 -
6 Hex nut M8 -
Procedure 1. Strech the metallic sheath between the vertical cutout in the cable tray
and the BTS rack (See Figure 39)
2. Fix the metallic sheath to the cable tray with one stove screw (See Figure 39)
3. Cut the metalic sheath to the right length (*1)
4. Fix a lug to the metallic sheath if necessary
5. Connect the metallic sheath tot he rack (See Figure 40)
6. Tighten the stripped PCM cable shielding to the sheath using the metallic tie
wrap provided in the kit (See Figure 40).
(*1) : when cutting the metal sheath, take care to avoid dropping small scraps
of copper into the rack.
9.2 Finishing
BTS STATION 2
Procedure 1. Affix the “ BTS STATION “ and “ N “ labels to the door of the BTS
2. Clear away packaging
3. Leave the site tidy
4. Leave the BTS door key
5. Clean the site.
Appendix A: Abbreviations
Abis Link between BTS and BSC
DC Direct Current
IO Instruction Operation
• mandatory kit
∇ technical choice kit
◊ 2 Mbits cables: - -
◊ Alcatel IDC terminal block 120 / 75 ohm JS10 1AD 06634 0011 4
◊ Jumpers to DDF: - -
Consumable Supplies The following table is used to check, at base, the availability of the installer’s
consumable supplies (not included in Alcatel kits).
Item Qty
Indelible marker 1
BSS site premises inspection, post handover 8BL 00704 0016 DRBRA
Installation method of DDF for BSS equipment 3DF 00435 0033 RJZZA
List of Necessary Tools The following table is used to check, at base, the availability of the necessary
tools (See ” Tools catalogue ” for content checking).