Sunteți pe pagina 1din 2

Power Electronic Experimental Kits / Components

(separate power circuit and control circuit PCB; heat sink mounted
Electronic Devices; power and control circuit on panel; voltage - current No.
observable signals through test plugs in range of (-10 V to +10 V wrt
common ground with isolation), built-in firing and commutation circuits)

a) Single-phase Dual Converter (Input : 1-phase, 230 V; rating 1kW;


output 0 to ± 200V, 5A; circulating current mode and interphase reactor;
1
signals for load/source voltage/current, circulating current, converter
voltage, thyristor voltage)

b) Voltage Commutated Chopper (Input : 1-phase, 230 V; rating 1kW;


output 0 to ± 200V, 5A; signals for load/thyristor/capacitor/source 1
voltage/current; internal DC generation through rectifier and adequate filter)

b) Current Commutated Chopper (Input : 1-phase, 230 V; rating 1kW;


output 0 to ± 200V, 5A; signals for load/thyristor/capacitor/source 1
voltage/current; internal DC generation through rectifier and adequate filter)

d) Three-phase Fully Controlled Bridge Converter (Input : 3-phase, 440


V; rating 1kW; output 0 to 200V, 5A; signals for load/source 1
voltage/current, thyristor voltage)

e) Single-phase Voltage Source Inverter (Input : 1-phase, 230 V; rating


1kW; output 0 to 200V, 5A, 5 - 100 Hz; uses IGBT/MOSFET; independent
voltage and frequency control, operating modes - square wave, single pulse, 1
sinusoidal pulse, current control; signals for load/source voltage/current,
thyristor voltage)
f) Single phase cycloconverter (input : 1-phase 230 V; output controllable
0-230 V, 5A, SCR based, signals for source /load/ voltage/current, thyristor 1
voltage)

h) Isolation Transformers (single phase, 230 V, 2 kVA) 2

Hall effect Voltage Sensors with Signal Processing CircuitInput voltage 0-


600V(DC,AC,Pulsed voltage)Output 5V/25mAFrequency 4
(0~20KHz)Accuracy ±0.8%Response time 40~200μS

Hall effect Current Sensors with Signal Processing Circuit


Input current 300-500A(DC,AC,Pulsed current)
Output current 100mA/150mA
Turns ratio 1:2000(300A);1:5000(500A) 6
Frequency DC~100KHz
Accuracy ±0.5%
Response time <1μS

Multiterminal regulated DC supply


(30V/3A, 2.5V/3.3V/5V/3A
Digital panel control 2
Coarse and fine Voltage/Current control
Software calibration)

S-ar putea să vă placă și