Documente Academic
Documente Profesional
Documente Cultură
High Ambient
Split Units VRV Rooftop Air Handling Units Air Cooled Chillers Water Cooled Chillers 50 Hz (46ºC OD)
Daikin world
Supermarket Factory
Technical
Sport &
Home Office Leisure
The perfect working environment is essential for all
businesses. From supermarkets to offices, from public
buildings to hotels, from factories to data centers,
it is essential that the quality of the air is optimised at all
times – but no space is used in exactly the same way and
that calls for flexible, tailored and economic solutions.
Daikin, the innovation leader for more than 90 years, understands
this and its ‘total solution’ concept is built around customised
solutions for individual clients. Whether cooling, heating, ventilation,
air curtains or refrigeration with intelligent control systems.
Daikin has the units, the experience and the solution for
you. Learn all about our solutions for your business.
Our promise...
... is to ensure that customers can depend on Daikin
for the ultimate in comfort, so that they are free to
focus on their own working and home lives.
We promise to dedicate ourselves to technological excellence,
a design focus and the highest quality standards so that our
customers can trust and rely on the comfort we deliver.
Our promise to the planet is absolute. Our products are at the
forefront of low energy-usage and we will innovate to further reduce
the environmental impact of HVAC-R (Heating, Ventilation, Air
conditioning, Refrigeration) solutions. We lead where others follow.
Product Range 6
DX Systems 10
Split Units 12
Rooftop (Packaged Unit) 14
VRV Systems 16
VRV IV Outdoor Unit 19
Wall Mounted Series 20
Ducted Series 20
Cassette Series 21
Air Purifier 22
Applied Systems 24
Air Cooled Chillers 26
Water Cooled Centrifugal Chillers 28
Chilled Water Fan Coil Units 30
Air Handling Units 33
Technical Information 44
FTKM- PVM
FTN-AV1K *(R)
FTN-AV1 30
Cooling Capacity (Kw) T1 22.4 28.0 44.8 50.4 56 67.02 72.8 78.4 84.0
VRV IV Indoor Unit Series Product Picture 15 20 25 32 40 50 63 71 80 100 125 140 200 250
Cooling Capacity (kW) 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8 9 11.2 14 16 22.4 28
FXFQ-A
FXCQ-M
FXDQ-A
FXSQ-A
Concealed Ceiling Unit
FXMQ-P7
FXMQ-MA/PVE
FXAQ-PVER1
Wall Mounted
FXAQ-PVE
FXHQ-M
Ceiling Suspended
FXUQ-A
FXLQ-P
Floor Standing
FXNQ-A
EWAD-TZ 48-194 TR
EWWD-G 46-171 TR
EWWD-H 105-345 TR
EWWD-I 95-430 TR
EWWQ-B 108-617 TR
WSC 200-1250 TR
WDC 400-2500 TR
WCC
1200-2700 TR
PRODUCTS OVERVIEW
WCT kW
Cooling Capacity
2500-3000 TR 0 5 10 15 20 25 30 35 40
FWW-L 2/3/4/5/6
Refrigerant R-134a
FWF-C 2/4/5
Chilled Water Fan Coil Units Product Picture CFM 200 300 400 500 600 700 800 900 1000 1200 1400 1600 1800 2000 2500 3000 4000 4600
FWK-E/
FWKE-E/ 5/6/8/9/11/13
FWW-DA FWKE-EH
FWE-E 5/6/7/8/10/12
FWW-C / F / H
FWE-D 7/9/13
2/2.5/3.5
FWC-FD FWC-FD /4/5/7/8
FWE
Air Handing Units Product Picture CFM 300 650 1000 5000 10000 15000 20000 25000 30000 35000 40000 50000 53000 60000 70000 80000 83000
2
D-AHU
DDM-AHU
DX Systems
Daikin offers the best available technologies for
Inverter
split system?
Powerful cooling performance, capacity and efficiency,
regardless of the outside temperature
Intelligent Eye
Daikin further enhances efficiency while
keeping comfort optimal by offering smart
technology like intelligent eye, which is able
to adjust the room temperature based on the
occupancy.
Wall Mounted FTNK20AV1K RNK20AV1K 1.50 3.66 3.20 474 224 1.91
(Non-Inverter)
R-410A
Premium
Rotary FTNK25AV1K RNK25AV1K 2.00 4.70 4.00 566 267 2.51
(Non-Inverter) R-410A
Rotary
FTN30AV1K RN30AV1K 2.33 6.10 6.10 760 359 3.28
FTN-AV1 30
FTN-AV1 30
Nominal Conditions (T1): 35 °C ambient and on coil of 27/19 DB/WB °C Piping Limitation: Wall Mounted
Actual Conditions: 46 °C ambient and on coil of 24/16 DB/WB °C at medium speed
All units up to 3TR nominal capacity are 220-240V/1Ph/50Hz and above are 380-415V/3Ph/50Hz
3.91 13.35 - 1/4" 1/2" 42 1050 259 340 15 930 350 695 46
3.72 12.70 - 1/4" 1/2" 45 1050 259 340 15 930 350 695 49
3.55 12.12 - 1/4" 5/8" 49 1200 259 340 18 930 350 695 49
3.23 11.04 - 1/4" 1/2" 39 1172 242 320 14 855 328 651 49
3.28 11.21 - 1/4" 5/8" 43 1172 242 320 14 855 328 753 57
3.23 11.04 - 1/4" 1/2" 39 1124 237 310 14 855 328 651 49
3.28 11.21 - 1/4" 5/8" 43 1124 237 310 14 855 328 753 57
2.88 9.84 - 3/8" 5/8" 46 1289 240 310 16 1030 400 852 77
Nominal Conditions (T1): 35 °C ambient and on coil of Piping Limitation: Ducted Split
27/19 DB/WB °C
EER ESP Pipe Size (Inch) Sound PR Indoor Dimension (mm) Weight Outdoor Dimension (mm) Weight
+ VRV IV core
technologies
› Newly developed inverter compressor
› 4 sided condenser coil
› Outer rotor DC Motor
+ Total Building
Solution
› Indoor line-up
› Fresh air
› Controls
Installers »
»
Simplified and time-saving commissioning with VRV configurator
Wide range of outdoor units (up to 48HP)
Daikin VRV IV sets the standard with state-of-art technology and
» One supplier = one point of contact
time-saving commissioning and servicing. » Maximum flexibility to meet customer requirements
» Customised training to maximise expertise
VRV IV Systems
Nom Capacity Power COP COP (ESMA )
Length Width Height Weight Combination
Capacity at 46C Input (Eurovent) (AHRI1230:2010)
Models
(kW) at No of
(TR) at 35°C (kW) at 35°C at 46°C mm mm mm kg model
46°C Modules
RXYTQ8T7YF 6.4 20.2 6.57 4.58 3.07 930 765 1680 188 RXYTQ8TYF 1
RXYTQ10T7YF 8.0 25.2 8.29 4.81 3.04 1240 765 1680 236 RXYTQ10TYF 1
RXYTQ12T7YF 9.5 28.5 8.64 4.13 3.30 1240 765 1680 236 RXYTQ12TYF 1
RXYTQ14T7YF 11.4 32 10.17 3.70 3.15 1240 765 1680 298 RXYTQ14TYF 1
RXYTQ16T7YF 12.8 35.1 11.63 3.52 3.02 1240 765 1680 298 RXYTQ16TYF 1
RXYTQ18T7YF 14.3 45.4 14.86 4.71 3.06 1240 + 930* 765 1680 424 RXYTQ10 + 8* 2
RXYTQ20T7YF 15.9 48.7 15.21 4.30 3.20 1240 + 930* 765 1680 424 RXYTQ12 + 8 2
RXYTQ22T7YF 17.5 53.7 16.93 4.41 3.17 1240 + 1240* 765 1680 472 RXYTQ12 + 10 2
RXYTQ24T7YF 19.1 57 17.28 4.13 3.30 1240 + 1240* 765 1680 472 RXYTQ12 + 12 2
RXYTQ26T7YF 20.9 60.5 18.81 3.89 3.22 1240 + 1240* 765 1680 534 RXYTQ14 + 12 2
RXYTQ28T7YF 22.3 63.6 20.27 3.75 3.14 1240 + 1240* 765 1680 534 RXYTQ16 + 12 2
RXYTQ30T7YF 24.2 67.1 21.8 3.60 3.08 1240 + 1240* 765 1680 596 RXYTQ16 + 14 2
RXYTQ32T7YF 25.6 70.2 23.26 3.52 3.02 1240 + 1240* 765 1680 596 RXYTQ16 + 16 2
RXYTQ34T7YF 27.0 82.2 25.57 4.31 3.21 1240 + 1240 + 1240* 765 1680 708 RXYTQ12+12+10 3
RXYTQ36T7YF 28.6 85.5 25.92 4.13 3.30 1240 + 1240 + 1240* 765 1680 708 RXYTQ12+12+12 3
RXYTQ38T7YF 30.4 89 27.45 3.96 3.24 1240 + 1240 + 1240* 765 1680 770 RXYTQ14+12+12 3
RXYTQ40T7YF 32.3 92.5 28.98 3.82 3.19 1240 + 1240 + 1240* 765 1680 832 RXYTQ14+14+12 3
RXYTQ42T7YF 33.6 95.4 31.55 3.76 3.02 1240 + 1240 + 1240* 765 1680 832 RXYTQ16+16+10 3
RXYTQ44T7YF 35.1 98.7 31.9 3.66 3.09 1240 + 1240 + 1240* 765 1680 832 RXYTQ16+16+12 3
RXYTQ46T7YF 37.0 102.2 33.43 3.57 3.06 1240 + 1240 + 1240* 765 1680 894 RXYTQ16+16+14 3
RXYTQ48T7YF 38.4 105.3 34.89 3.52 3.02 1240 + 1240 + 1240* 765 1680 894 RXYTQ16+16+16* 3
VRV IV Systems
at 24°C / 17°C WB Length Width Height
- nominal kW cfm L/s High
kW MBH kW MBH Pa mm mm mm dBA kg
FXMQ50P 5.6 19.1 4.9 16.7 0.11 636 300 100-200 1000 700 300 39 42
FXMQ63P 7.1 24.2 6.2 21.2 0.12 689 325 100-200 1000 700 300 40 42
FXMQ80P 9 30.7 7.8 26.6 0.171 883 417 100-200 1000 700 300 41 42
FXMQ100P 11.2 38.2 9.8 33.4 0.176 1130 533 100-200 1400 700 300 41 54
FXMQ125P 14 47.8 12.2 41.6 0.241 1377 650 100-200 1400 700 300 44 54
FXMQ140P 16 54.6 14 47.8 0.461 1624 767 100-200 1400 700 300 45 47
FXMQ200MA* 22.4 76.4 19.5 66.5 1.3 2048 967 132-221 1380 1100 470 48 137
FXMQ250MA* 28 95.5 24.4 83.3 1.5 2543 1200 191-270 1380 1100 470 48 137
*Air filter & drain pump option
Air Purifier
generating high speed electrons, a feat that has been
the considered difficult up to now. Destroys
• Super quiet 99.6% of allergy
operation
espiratory
air and • Easy to Odours
maintain neutralization
o: Main specifications
• PortableUltra quiet operation (16dBA)
Daikin has already received great praise for its air
purifiers: a British Allergy Foundation seal of approval Portable (8.5 KG)
• No installation
and the TÜV Nord test mark confirm the efficiency of
our units. No need of installation
Easy maintenance
Indoor unit MC70L
Applicable room area Economical m² 46
Dimensions Unit HeightxWidthxDepth mm 576x403x241
Weight Unit kg 2 8.5
Casing Colour White
Fan Type Multi Blade Fan (Sirocco fan with shroud assembly)
Air flow rate Air Turbo/High/ m³/h
purifying Medium/Low/ 420/285/210/130/55
operation Silent
QUICK SELECTION GUIDE 2016 23
Chillers
No matter how large your premises and whatever your air
Daikin chillers offer the ultimate in reliability and conditioning needs in climate control or process cooling and
heating, there is a system that has proved worthy in a multiplicity
flexibility — a reflection of the advanced technology
of situations - from industrial sites to retail warehouses, hotels and
inherent within them. Daikin chillers represent the sure department stores.
Applied Systems
› In-house development and manufacturing of chiller main components (compressors, fans
condenser coils, software, etc.)
Applied Systems
EWADC21C-XS 501.70 84.2 2540x2285x14785 81
EWADC22C-XS 514.50 86.3 2540x2285x14785 81
Cooling Capacity is based on 46 °C Ambient Temperature, and water in/out at 7/12 °C
Refrigerant R-134a
WMC Magnetic
Bearing
100 - 400 TR
WSC
200 - 1100 TR
WDC
400 - 2200 TR
WCC
1200 - 2350 TR
WCT
2500 - 3000 TR
Applied Systems
» R-134a - No Phase-out Refrigerant » NPLV of up to 0.33 kW/TR
» Semi-hermetic Compressor » Virtually maintenance free operation
» Gear driven impeller » AHRI-certified performance
» Movable discharge diffuser for better unloading
Centrifugal Chillers
WCT: 2500-3000 TR
Applied Systems
QUICK SELECTION GUIDE 2016 31
Decorative Under Ceiling Chilled Water Fan Coil Units
Water Rated Sound
Water
Air Flow Cooling Capacity Pressure Power Pressure Dimensions
flow Weight
Models Model Image Drop Input Level
Total Sensible Length Depth Height
CFM l/s m3/h kPa kW db(A)
kW kW mm mm mm kg
FWE06E 530 250 3.76 3.06 0.18 26.7 0.108 43 1090 630 212 27
FWE07D 690 326 5.41 4.13 0.26 31.3 0.121 50 1214 670 249 45
FWE07E 560 264 3.86 3.21 0.18 31.1 0.115 46 1090 630 212 27
FWE08E 750 354 4.86 4.14 0.23 17.4 0.157 47 1320 635 259 41
FWE10E 980 463 6.87 5.44 0.33 25.5 0.187 47 1538 635 259 46
FWE12E 1080 510 10.45 7.43 0.5 40 0.25 50 1786 635 259 53
FWE13D 1020 481 10.07 7.49 0.48 24.3 0.193 53 1714 670 249 70
Above performance data is based on following conditions:
Cooling : 24°C DB / 17°C WB and water inlet 7°C outlet 12°C » Sound pressure level is tested at microphone position 1m in front of the unit and 1m below the air
Medium speed, 0 Pa ESP discharge opening
220V/1ph/50Hz
Applied Systems
the most energy efficient in the market,
thus reducing their ecological impact,
while, at the same time, keeping costs
down through the minimisation of
energy consumption.
Air Handling Units make our air handling units ideal for all
markets.
Applied Systems
AHUs include Prefilter (G4)+ Bag Filter (F7) + Cooling Coil + DWDI, Backward Curved Fan
AHU's include Prefilter (G4)+ Bag Filter (F7) + DX Cooling Coil + DWDI, Backward Curved Fan
l/s l/s kW kW °C °C °C °C
°C °C kW kW °C °C l/s kPa mm kg
31.5/21.67 21/16 21.20 12.90 24.2/19.4 13.7/13.49 1.01 30 1550 x 1290 x 3810 825
32.5/22.2 21/16 35.00 21.00 25.2/20.1 13.7/13.7 1.67 33 1520 x 1500 x 3880 960
32.5/22.2 21/16 46.88 28.13 25.2/20.1 13.7/13.67 2.24 30 1700 x 1670 x 4110 1136
32.5/22.43 21/16 60.44 35.06 25.2/20.3 13.7/13.7 2.89 44 1840 x 1830 x 4150 1349
32.5/22.43 21/16 72.53 42.07 25.3/20.6 13.7/13.7 3.46 25 1960 x 1970 x 4470 1556
32.4/22.35 21/16 83.16 49.06 25.1/20.2 13.7/13.7 3.97 30 2310 x 2080 x 4470 1715
32.4/22.35 21/16 95.04 56.07 25.1/20.2 13.7/13.7 4.54 37 2380 x 2210 x 4730 1965
32.4/22.35 21/16 107.27 63.29 25.1/20.2 13.7/13.67 5.12 44 2620 x 2310 x 4730 2088
32.4/22.35 21/16 118.79 70.09 25.1/20.2 13.7/13.7 5.67 25 2680 x 2420 x 4800 2226
32.4/22.35 21/16 142.55 84.10 25.1/20.2 13.7/13.7 6.81 23 2660 x 2620 x 4930 2561
32.4/22.35 21/16 166.31 98.12 25.1/20.2 13.7/13.7 7.94 29 2990 x 2800 x 5230 2980
32.5/22.43 21/16 193.42 112.18 25.2/20.3 13.7/13.7 9.23 38 3180 x 2970 x 5430 3304
Applied Systems
32.6/22.51 21/16 221.37 128.39 25.3/20.4 13.7/13.7 10.57 37 3220 x 3120 x 5550 3562
32.4/22.35 21/16 245.97 142.66 25.3/20.4 13.7/13.7 11.74 44 3520 x 3300 x 5780 4218
32.4/22.35 21/16 261.55 154.31 25.1/20.2 13.7/13.7 12.49 49 3680 x 3500 x 5810 4695
l/s l/s kW kW °C °C °C °C
°C °C kW kW °C °C l/s kPa mm kg
32.4/22.35 21/16 285.11 168.21 25.1/20.2 13.7/13.7 13.61 21 3800 x 3630 x 5950 4998
32.4/22.35 21/16 308.86 182.23 25.1/20.2 13.7/13.7 14.75 14 3920 x 3760 x 6120 5361
32.4/22.35 21/16 332.62 196.25 25.1/20.2 13.7/13.7 15.88 16 4060 x 3890 x 6120 5604
32.4/22.35 21/16 356.38 210.26 25.1/20.2 13.7/13.7 17.01 19 4120 x 4010 x 6270 5898
32.4/22.35 21/16 380.14 224.28 25.1/20.2 13.7/13.7 18.15 21 4300 x 4130 x 6310 6349
32.4/22.35 21/16 403.90 238.30 25.1/20.2 13.7/13.7 19.28 23 4420 x 4240 x 6310 6406
32.4/22.35 21/16 427.66 252.32 25.1/20.2 13.7/13.7 20.42 26 4720 x 4350 x 6920 6933
32.5/22.43 21/16 459.36 266.43 25.2/20.3 13.7/13.7 21.93 19 4560 x 4460 x 6920 7227
32.24/23.68 21/16 569.69 274.48 24.9/21.6 13.7/13.7 28.49 25 4620 x 4560 x 5990 7124
32.2/23.65 21/16 626.52 288.20 24.9/21.6 13.7/13.7 29.91 34 4640 x 4720 x 5960 7391
32.17/23.62 21/16 656.36 301.93 24.9/21.6 13.7/13.7 31.34 38 4580 x 4930 x 5960 7603
32.3/23.76 21/16 696.39 320.34 25.0/21.7 13.7/13.7 33.25 44 4600 x 5180 x 6100 7840
Applied Systems
32.4/23.81 21/16 737.36 339.19 25.1/21.8 13.7/13.7 35.19 50 4600 x 5390 x 6100 8112
32.3/23.77 21/16 756.95 348.20 25.0/21.7 13.7/13.7 36.14 44 4620 x 5600 x 6130 8728
l/s l/s kW kW °C °C °C °C
FAHU extract section includes RA Damper + Prefilter (G3) + Heat Recovery Wheel + DWDI, Backward Curved Fan
°C °C kW kW °C °C mm kg
31.5/21.67 21/16 23.00 13.20 24.2/19.4 13.7/12.88 1550 x 1290 x 3740 807
32.5/22.2 21/16 38.90 21.80 25.2/20.1 13.7/12.85 1520 x 1500 x 3810 945
32.5/22.2 21/16 51.80 29.00 25.2/20.1 13.7/12.87 1700 x 1670 x 4040 1116
32.5/22.43 21/16 66.30 36.30 25.2/20.3 13.7/12.95 1840 x 1830 x 4080 1332
32.5/22.43 21/16 79.70 43.50 25.3/20.6 13.7/13.93 1960 x 1970 x 4450 1548
32.4/22.35 21/16 91.80 50.30 25.1/20.2 13.7/12.91 2310 x 2080 x 4450 1705
32.4/22.35 21/16 104.90 57.50 25.1/20.2 13.7/12.9 2380 x 2210 x 4710 1956
32.4/22.35 21/16 117.70 64.70 25.1/20.2 13.7/12.93 2620 x 2310 x 4710 2088
32.4/22.35 21/16 131.00 71.90 25.1/20.2 13.7/12.92 2680 x 2420 x 4780 2226
32.4/22.35 21/16 156.30 86.30 25.1/20.2 13.7/12.96 2660 x 2620 x 4910 2555
32.4/22.35 21/16 183.40 100.60 25.1/20.2 13.7/12.91 2990 x 2800 x 5210 2982
32.5/22.43 21/16 212.50 116.10 25.2/20.3 13.7/12.93 3180 x 2970 x 5360 3298
Applied Systems
QUICK SELECTION GUIDE 2016 43
Technical Information
Motor Efficiency Information Hygienic Units Pre-Requirements
Never specify IE1 (EFF2) motors. Any heat exchanger should not be wider than 300 mm and with access on both
On 22 July 2009, Commission Regulation (EC) No 640/2009 implementing Directive sides to allow cleaning. Keep the number of rows to max 6, however, if 8 rows comes
2005/32/EC states that in the EU, with the exception of some special applications, in 300 mm, then it is ok.
motors shall not be less efficient than the IE3 efficiency level as from 1 January 2015.
» T2/TB2 construction minimum
In detail: » Internal skin made of aluminum alloy or AISI 304 (preferable)
» IE2 by June 16, 2011 » On viewable surfaces like dampers or doors gasket must be rubber/EPDM (open
» IE3 by January 1, 2015 (for motors >=7.5 to 375 kW) and IE2 only in combination or closed cell gasket not acceptable)
with an adjustable speed drive » Only front release filter frame
» IE3 for all motors by January 1, 2017, (for motors from 0.75 to 375 kW). » Coil with aluminum or stainless steel frame. Fins preferably with ALUVER paint
» Coils with access on both side of the coil for cleaning
» Sloped drain pan made of stainless steel
DX Coil Capacity » Moisture eliminator made of stainless steel if required. Usually not recommended.
Total cooling capacity for AHU DX coil MUST be equal to the Condensing Unit » Sound attenuator stainless steel frame and film protection (melinex or similar to
cooling capacity. protect against fiber migration. Perforated plate also acceptable however not
recommendable as difficult to clean
AHU DX coil evaporation temperature MUST be equal to Condensing Unit saturated » Epoxy painted fan with paint strong enough to resist against abrasion. Typically a
suction temperature + 2°F. 4 layer epoxy pain. Only plug fans acceptable
» Sealant food grade
No. of AHU DX coil refrigerant circuits MUST be equal to the no. of Condensing Unit » No hollow sections allowed and if tubular frames are to be used they must be
refrigerant circuits. closed at the end with caps or welded
Temperature Rise
Electrical Power Input Calculation Temperature rise due to air compression (fan work):
Belt-Driven fans :
Electrical Power Input calculation = (Break power + 12% drive loss) / efficiency
EC fans :
Electrical Power Input is same as the shaft power. Where :
∆T : Fan Temperature rise
Ps : Fan brake shaft power
SFP Calculation μ : Fan efficiency
Cp : Specific heat capacity (1 for air)
q : air flow in m3/s
Where : p : density (1.2 kg/m3)
SFP: AHU Specific Power Input
For a fan 5.56 m3/s @ 14.6 kw break power at 72% fan efficiency the temperature rise
: Sum of all electric power input of the fan inside the AHU. So if you have 2 is approximately 0.6 °C
fan supply + 2 fan return your will have 4 power input
Temperature rise due motor heat rejection :
AF: This should be the AHU total supply air flow or if the unit is with supply and
return fans then the highest between the two
For a 18.5 kW motor at 5.53 m3/s at 85% motor efficiency the temperature rise is
approximately 0.41°C
Applied Systems
Coil Bypass Factor & Efficiency Formula
Coil Bypass Factor = (Air Outlet Temperature – T) / (Air Inlet Temperature – T)
T : Fluid Average Temperature
Fluid average temperature = (Inlet Temp + Outlet Temp)/2
∆T : Temperature difference, °C
∆h : Enthalpy difference, kJ/kg
∆w : Moisture concentration, g/kg dry air
Q : Air flow rate, m³/s
< 135000 8.1 Single Package < 19 3.4 9.7 19-40 3.4 11.6
Split system
All Other Split and 135000 - 240000 7.9 19-40 3.22 40-70 3.3 11.3
and single
Package Units
DX 240000 - 760000 7.5 40-70 3.16 package 70-223 3.13 10.7 2.87 9.8
no 3.4
≥ 760000 7.2 Split system 70-223 2.87 2.78 ≥ 223 3.02 10.3 2.78 9.5
and single
< 90000 8.3 ≥ 223 2.78 2.69 < 19 3.4 11.6
package
Multi Split VRF
(including VRV) 90000 - 135000 7.8 19-40 3.28 11.2
3.4 multisplit air
≥ 135000 7.5 condtioners 40-70 3.22 11
Units kW Btu /Wh kW kW/kW ≥ 70 2.93 10
Temperature
35°C 52°C 35°C 35°C
condition
Air Cooled < 630 8.5 3.4 Air cooled All 2.83 3.69
Air cooled All 2.8 3.05
≥ 630 9.5 3.4
< 528 13.5 Reciprocating All 4.2 5.05 3.4 <264 4.51 5.59
Water cooled
Chillers yes < 528 4.45 5.25 3.4 positive 264-528 4.54 5.72
Water Cooled displacement
528-1055 15 Rotary screw 528-1055 4.9 5.60 3.4 528-1055 5.18 6.07
≥ 1055 kW 5.5 6.15 3.4 ≥1055 5.68 6.52
< 528 5 5.25 3.4 <1055 5.68 5.91
Water cooled
≥ 1055 17 Centrifugal 528-1055 5.55 5.9 3.4 1055-2110 6.11 6.41
centrifugal
≥ 1055 6.1 6.4 3.4 ≥2110 6.18 6.53
Authority ESMA Abu Dhabi Urban Planning Council QCC -voluntary certification scheme, link with Estidama
35°C 46°C 35°C 46°C 48°C 52°C 35°C 46°C 35°C 46°C
Split Split
Split system < 65000 9.5 6.6 <70000 11.5 8.28 ≤70000 9.5 6.84 Split system ≤70000 9.5 6.84
system system
Single
< 65000 9.5 6.6
Package Split ≥70000 Split ≥70000 Split ≥70000
65000 - 135000 9.5 6.6
135000 - 240000 9.5 66
All DX All 1.6 yes
240000 - 760000 9.5 6.6 Package All Package All Package All
Split system
and single ≥ 760000 9 6.3
package
Multi split Multi split Multi split
(including All (including All (including All
VRV) VRV) VRV)
Btu / Btu /
tons
Wh Wh
35°C 46°C
Air Air
Air cooled All 2.8 1.9 3.05 Air Cooled All 1.6 Air Cooled
Cooled Cooled
Reciprocating
All 4.2 2.75 5.05 < 250 1.45
Utpal Joshi Ramesh Veluchamy Mohamed Tarek Hajeh Mohamed Fathy Alazab
VRV, DX Chiller & Air Side VRV, DX Consulting Sales
GSM: 00971 50 557 8464 GSM: 00971 52 741 9428 GSM: 00971 52 741 8739 GSM: 00974 55 576 619
E-mail: joshi.u@daikinmea.com E-mail: veluchamy.r@daikinmea.com E-mail: hajeh.m@daikinmea.com E-mail: alazab.m@daikinmea.com