Date Site Issue fixed Problem

15/1/2018 ZNJ085 Yes Rx Path /RX Diversity


15/1/2018 ZNJ659 Yes Rx Path /RX Diversity
15/1/2018 ZNJ350 Yes Rx Path /RX Diversity
15/1/2018 ZNJ562 Yes Rx Path /RX Diversity
15/1/2018 ZJD932 No Sec #1 All technologies RETs are Disabled
16/1/2018 GJD937 Yes Alarm is active
16/1/2018 ZNJ009 Yes Rx Path /RX Diversity
16/1/2018 ZNJ667 Yes Rx Path /RX Diversity
16/1/2018 HJD890 Yes Rssi Issue
16/1/2018 GJD890 Yes Rssi Issue /S1 all technologies RETs diabled
17/1/2018 ZJD021 Yes Rx Path /RX Diversity
17/1/2018 ZJD990 Yes RX Diversity
17/1/2018 ZNJ111 Yes RX Diversity
17/1/2018 ZNJ500 Yes RX Diversity
17/1/2018 ZNJ585 Yes RX Diversity
17/1/2018 GNJ719 No 3G all sectors RETs disabled
17/1/2018 GJD620 Yes Lublimits HS
18/1/2018 ZJD725 Yes RX Diversity
18/1/2018 ZNJ754 Yes Rx Path /RX Diversity
18/1/2018 ZNJ348 Yes RX Diversity
18/1/2018 ZNJ197 Yes RX Diversity
18/1/2018 GNJ074 Yes 2 sectors all RETs disabled
18/1/2018 ZNJ547 No Rx Path /RX Diversity
18/1/2018 FNJ046 No SFP alarm
20/1/2018 ENJ036 No sectors swap
20/1/2018 ZNJ631 Yes Door alarm
20/1/2018 ENJ049 Yes RSSI & SFP alarm
20/1/2018 ZNJ234 Yes Door alarm
20/1/2018 HNJ348 Yes Sec #3 TMA port A Current too high alarm
20/1/2018 ZNJ672 Yes Rx Path /RX Diversity
21/1/2018 ZNJ823 No Rx Path /RX Diversity
21/1/2018 ZNJ901 Yes Rx Path /RX Diversity
21/1/2018 EJD055 Yes Sector swap /RETs disable
21/1/2018 ENJ389 Yes all sectors RETs disable
21/1/2018 GJD275 Yes Sector #3 LTE1800 RET disable
21/1/2018 GJD855 No RETs disabled on Sec #2
22/1/2018 ZJD021 Yes Battery Capacity Reduced
22/1/2018 ENJ115 Yes Rets disabled
22/1/2018 ZNJ647 Yes Rx Path /RX Diversity
22/1/2018 ZJD953 Yes Rx Path /RX Diversity
22/1/2018 GJD953 RSSI High
22/1/2018 ZJD952 No NA
22/1/2018 ZJD386 No NA
23/1/2018 ENJ115 Yes Rets disabled
23/1/2018 ZNJ722 Yes External alarms need to configure
23/1/2018 ZNJ139 Yes External alarms need to configure
23/1/2018 ZNJ390 Yes Door alarm need to configure
23/1/2018 ZJD965 No Battery bank cabinate door open alarm
23/1/2018 HNJ339 Yes Low power in TMA
23/1/2018 ZJD644 Yes Battery bank cabinate door open alarm
24/1/2018 ZNJ160 No Rx Path /RX Diversity
24/1/2018 EJD273 No No Connection alarm
24/1/2018 ENJ547 No No Connection alarm
24/1/2018 ZJD953 Yes Rx Path /RX Diversity
24/1/2018 ZJD695 No Battery bank cabinate door open alarm
25/1/2018 ZJD273 Yes Rx Path /RX Diversity
25/1/2018 HNJ717 Yes RSSI High /Sectors Swap
25/1/2018 ZNJ717 L700 Yes sector swap
25/1/2018 ZNJ717 Yes ICM High /sector swap
25/1/2018 GNJ423 Yes All sectors all Technologies RETs disable
25/1/2018 ZNJ507 No BTS Fault
27/1/2018 ZNJ139 Yes External Alarm issue
27/1/2018 ZNJ329 Yes Rx Path /RX Diversity
27/1/2018 ZNJ823 Yes Rx Path /RX Diversity
27/1/2018 ZJD953 Yes Some TRX connection Lost
27/1/2018 ZNJ414 Yes Rx Path /RX Diversity
28/1/2018 ENJ823 No Ri link failure
28/1/2018 ENJ762 No Servie degradation alarm on Sec 2
28/1/2018 TJD674 Yes Rssi issue
28/1/2018 ZJD900 Yes Rx Path /RX Diversity
28/1/2018 ZNJ169 Yes Rx Path /RX Diversity
28/1/2018 ZJD695 No Battery cabinate door open alarm
29/1/2018 ZNJ579 Yes Door open alarm
29/1/2018 ZNJ339 No NA
29/1/2018 ZNJ414 Yes Permanet fault alarm on 2G 1800 RUS
29/1/2018 ZJD953 Yes Alarm /Swap &ICM value high
29/1/2018 ZNJ952 Yes Rx Path /RX Diversity
29/1/2018 ENJ382 Yes No Connection alarm
30/1/2018 ZNJ952 Yes Rx Path /RX Diversity
30/1/2018 ZJD412 Yes Battery Capacity Reduced
30/1/2018 ZNJ261 Yes Door alarm is active
30/1/2018 IJD153 Yes Door alarm /high temperature alarm are
active
30/1/2018 ZNJ339 No Rx Path /RX Diversity
30/1/2018 ENJ015 No SFP alarm
30/1/2018 ZNJ842 Yes Rx Path /RX Diversity
31/1/2018 ZJD493 No tx lub HS limitation impacting GJD493
31/1/2018 ZMK541 No RSL issue
31/1/2018 ZJD535 No Low modulation RCC/HCC/ICC alarm on
MW
01-Feb-2018 GNJ671 Yes Cell B /F Down ,Connection lost
01-Feb-2018 GNJ823 Yes RETs disabled of sec#2 /sec#3
01-Feb-2018 ZNJ169 Yes Rx Path /RX Diversity
01-Feb-2018 ZNJ952 Yes Rx Path /RX Diversity
01-Feb-2018 ZNJ451 No tx lub HS limitation impacting HNJ451
03-Feb-2018 ZNJ036 Yes Rx Path /RX Diversity
03-Feb-2018 HNJ036 Yes Rssi Issue
03-Feb-2018 GNJ036 No Rssi high ,Traffic issue
03-Feb-2018 ZJD958 Yes Rx Path /RX Diversity
03-Feb-2018 ZNJ139 Yes TX issue on 2G 1800
03-Feb-2018 GNJ139 (L2100) Yes Swap between B & C
03-Feb-2018 ZJD932 No RET Disabled
03-Feb-2018 ZNJ145 No No Connection alarm
04-Feb-2018 ZNJ952 Yes Rx Path /RX Diversity
04-Feb-2018 ZJD554 Yes Rx Path /RX Diversity
04-Feb-2018 ZJD061 Yes Rx Path /RX Diversity
04-Feb-2018 EJD075 No Link failure alarm
04-Feb-2018 GJD873 No Sec #3 Rets are disabled
04-Feb-2018 G/HJD877 No RETs issue
05-Feb-2018 ZNJ397 Yes Rx Path /RX Diversity
05-Feb-2018 ZJD958 Yes Rx Path /RX Diversity
05-Feb-2018 ZNJ139 Yes TX issue on 2G 1800
05-Feb-2018 ZJD507 No BTS Fault
05-Feb-2018 G/HJD877 No RET Disabled
05-Feb-2018 ZJD467 Yes Rx Path /RX Diversity
06-Feb-2018 ZJD952 Yes Rx Path /RX Diversity
06-Feb-2018 ZNJ958 Yes Rx Path /RX Diversity
06-Feb-2018 ZNJ515 Yes PSU Main Failure
06-Feb-2018 GNJ156 No RET Disabled
06-Feb-2018 GMK309 No RET Disabled
07-Feb-2018 ENJ383 Yes Sectors swap A&B
07-Feb-2018 ZNJ082 Yes ICM High
07-Feb-2018 ENJ082 Yes Sectors swap B&C
07-Feb-2018 GNJ065 Yes RET Disabled
07-Feb-2018 GNJ065 L700 No Ri link failure
08-Feb-2018 ENJ376 Yes No Connection alarm
08-Feb-2018 EJD508 No Rssi fluctuation on all sectors
08-Feb-2018 ZNJ796 Yes Rx Path /RX Diversity
08-Feb-2018 ZNJ665 Yes Rx Path /RX Diversity
08-Feb-2018 ZNJ145 No No Connection alarm
10-Feb-2018 HJD996 No RETs alarm
10-Feb-2018 TNJ408 Yes Enclosure product data mismatch
10-Feb-2018 ZJD336 Yes Radio X reciver
10-Feb-2018 TNJ736 Yes Enclosure product data mismatch
10-Feb-2018 ENJ550 Yes No connection alarm
11-Feb-2018 EJD923 No Vswr and Swap
11-Feb-2018 EJD438 Yes Rssi High and Erab Drop
11-Feb-2018 GNJ611 Yes HW alarm
11-Feb-2018 ZJD744 No Main failure alarm
11-Feb-2018 IJD275 No Radio X reciver
11-Feb-2018 GNJ334 Yes RETs Disabled
12-Feb-2018 ZJD061 Yes Main failure alarm
12-Feb-2018 EJD898 Yes HW fault alarm
12-Feb-2018 GNJ539 Yes No Connection alarm
12-Feb-2018 GJD877 No RET Disabled
13-Feb-2018 ENJ012 Yes Ri link failure
13-Feb-2018 EJD991 Yes Ri link failure
13-Feb-2018 TNJ994 Yes Enclosure product data mismatch
13-Feb-2018 ENJ519 Yes SFP low pwr alarm
13-Feb-2018 TNJ713 Yes Disconnected alarm
13-Feb-2018 ZJD106 No Main failure alarm
13-Feb-2018 TNJ145 No No Connection alarm
14-Feb-2018 ZNJ796 Yes Rx Path /RX Diversity
14-Feb-2018 ZNJ321 Yes cell A&B Down, Traffic lost alarm
14-Feb-2018 GJD923 Yes RETs Disabled
14-Feb-2018 ZJD386 No Battery Capacity Reduced
15-Feb-2018 ZNJ010 Yes Radio X reciver
15-Feb-2018 ZJD270 Yes Main failure alarm
15-Feb-2018 GNJ079 Yes RET Disabled
15-Feb-2018 GNJ334 Yes RET Disabled
17-Feb-2018 ENJ017 No Power loss alarm L700
17-Feb-2018 HNJ545 Yes Delta /Rssi High
17-Feb-2018 TNJ545 Yes TDD F1,F2 Cell A&B
17-Feb-2018 ZNJ708 No Rssi High
17-Feb-2018 ENJ296 Yes L1800 Feeder Swap
18-Feb-2018 HNJ249 Yes Rssi High
18-Feb-2018 HJD940 Yes Rssi High
18-Feb-2018 HNJ120 Yes Rssi High
18-Feb-2018 GJD873 No Ret Tilt out of range
19-Feb-2018 GNJ665 Yes Cells Down /HW alarm
19-Feb-2018 ZNJ665 Yes Cells Down /HW alarm
19-Feb-2018 TJD674 Yes Erab Drop on 3rd sec
19-Feb-2018 IJD238 Yes Radio X reciver
20-Feb-2018 EJD897 No Vswr High Sec#3 L700
20-Feb-2018 ENJ010 No Sec#A intermittenly down
20-Feb-2018 ZNJ312 Yes Cells Down
20-Feb-2018 ZJD508 Yes Rx Path /RX Diversity
20-Feb-2018 TNJ197 Yes Sector swap F1 A&C
20-Feb-2018 G/HNJ197 Yes High Rssi /RETs disabled
20-Feb-2018 ZJD250 Yes Radio X reciver
20-Feb-2018 IJD082 Yes Radio X reciver
21-Feb-2018 HJD250 Yes RSSI High /Delta
21-Feb-2018 HNJ312 Yes RSSI High /Delta
21-Feb-2018 HNJ219 No RSSI High /Delta
21-Feb-2018 HNJ019 Yes RSSI High /Delta
22-Feb-2018 ZNJ816 No Sector Swap A&C
22-Feb-2018 TNJ816 No Sector Swap A&C
22-Feb-2018 GNJ816 Yes Sector Swap L2100 B&C
22-Feb-2018 ZNJ321 Yes Sector Swap U900 A&C
22-Feb-2018 ZNJ074 Yes Sector Swap 3G2100 B&C
24-Feb-2018 ZNJ302 Yes Sector swap L1800 A&B
24-Feb-2018 ZJD055 Yes Sector swap L700/L2100 B&C
24-Feb-2018 ZNJ545 Yes Sector swap TDD F1,F2 B&C
24-Feb-2018 ZNJ516 Yes Sector swap GSM A&C
24-Feb-2018 ZJD877 Yes Sector swap L1800 A&C
24-Feb-2018 ZNJ383 Yes Sector swap L1800 A&B,TDD F1 A&C
24-Feb-2018 ZJD923 No Sector swap U900 /L2100
25-Feb-2018 ZNJ197 Yes L1800 swap A&C ,TDD F1-F2 A&C, U900 A&C
25-Feb-2018 ZJD488 Yes L1800 swap A&C ,TDD F1-F2 A&C, U900 A&C
Clock wise
25-Feb-2018 ZJD991 No L1800 A&B swap
26-Feb-2018 ZNJ203 Yes L700 Swap B&C
26-Feb-2018 ZJD902 No L1800 A&B swap
26-Feb-2018 ZNJ578 Yes L1800 CW A/B/C Swap
26-Feb-2018 ZJD556 Yes L700 CW A/B/C Swap
27-Feb-2018 ZJD137 Yes Sector swap L1800 A&C
27-Feb-2018 ZNJ816 Yes/No L1800 A&C Swap /2G900 B&C swap
27-Feb-2018 ZNJ514 Yes L1800 A&B swap
28-Feb-2018 ZJD923 No L700 Swap CW A/B/C
28-Feb-2018 ZNJ089 Yes L700 Swap B&C
28-Feb-2018 ZNJ503 Yes L700 Swap A&B
28-Feb-2018 ZNJ816 Yes 2G 900 Swap B&C
01-Mar-2018 ZNJ295 Yes TDD F1,F2 CW A/B/C
01-Mar-2018 ZNJ901 Yes L2100 CW Swap A/B/C
01-Mar-2018 ZJD991 Yes L1800 A&B swap
01-Mar-2018 ZNJ072 Yes L2100 A&B Swap
01-Mar-2018 ZNJ257 No L1800 Feeder Swap
01-Mar-2018 ZJD137 No TDD F1,F2 Cell A&B
03-Mar-2018 ZJD013 Yes TDD F1,F2 Cell A&B
03-Mar-2018 ZNJ641 Yes L1800 A&B Swap
03-Mar-2018 ZNJ228 Yes L1800 A&B /L700 CW/L2100 CW swap
03-Mar-2018 ZJD137 Yes TDD F1,F2 CW A/B/C
03-Mar-2018 ZJD121 No All Technologies swap
04-Mar-2018 ZNJ296 Yes L1800 Swap B&C
04-Mar-2018 ZNJ823 Yes L700 Swap B&C
04-Mar-2018 ZJD935 Yes L700 Swap A&B
04-Mar-2018 ZNJ519 Yes L700 Swap CW A/B/C
04-Mar-2018 ZNJ661 No 3G Swap CW A/B/C
05-Mar-2018 ZNJ411 Yes L700 B&C Swap
05-Mar-2018 ZNJ661 Yes 3G Swap B/C
05-Mar-2018 ZJD179 Yes U900 Swap CW A/B/C
06-Mar-2018 ZJD150 Yes 3G Swap A&B
06-Mar-2018 ZJD245 Yes L700 Swap CW A/B/C
06-Mar-2018 ZJD313 No L1800 Swap B&C
07-Mar-2018 ZNJ904 Yes Servie degradation alarm on Sec 2
09-Mar-2018 ZJD275 Yes Rssi &Vswr High
09-Mar-2018 ZNJ079 Yes Rssi High
09-Mar-2018 ZNJ212 No Rssi &RETs disabled
10-Mar-2018 ZNJ551 No L700 all sectors Rssi issue
10-Mar-2018 ZJD105 No Rssi Issue
12-Mar-2018 ZJD816 Yes TDD F1 Swap A&B
12-Mar-2018 ZNJ328 Yes L700 Swap
12-Mar-2018 ZNJ904 Yes U2100 CW Swap
12-Mar-2018 ZNJ658 Yes L700 Swap A&B
12-Mar-2018 ZNJ623 Yes L1800 A&B sec Swap
12-Mar-2018 ZJD160 No L1800 B&C swap
13-Mar-2018 ZJD939 Yes L700 Swap
13-Mar-2018 ZNJ079 Yes L700 Swap A&B
13-Mar-2018 ZNJ302 Yes L1800 Swap A&B
13-Mar-2018 ZNJ065 Yes L700 Swap
13-Mar-2018 ZNJ478 Yes L2100 Swap A&B
14-Mar-2018 ZNJ329 Yes TDD Swap A&B
14-Mar-2018 ZNJ389 Yes L700 Swap
14-Mar-2018 ZNJ713 Yes L1800 A&B swap
14-Mar-2018 ZNJ064 Yes L700 A&B Sector swap
14-Mar-2018 ZNJ535 Yes U2100 B&C Swap
14-Mar-2018 ZNJ162 Yes L2100 A&B Swap
15-Mar-2018 ZNJ847 Yes L700 CW A/B/C Swap
15-Mar-2018 ZNJ577 Yes U900 Swap
15-Mar-2018 ZJD950 Yes L1800 B&C swap
15-Mar-2018 ZJD214 Yes U2100 Swap
15-Mar-2018 ZNJ005 Yes U900 Swap
19-Mar-2018 ZNJ764 Yes LTE2300 Rssi , Vswr
19-Mar-2018 ZJD898 Yes 3G2100 Rssi
20-Mar-2018 GNJ072 Yes High Rssi /Delta sec 2
20-Mar-2018 TNJ072 Yes High Rssi B&C Cell
20-Mar-2018 HNJ072 Yes High Rssi /Delta sec 3
20-Mar-2018 TJD343 Yes High Rssi on Cell B/Traffic issue
20-Mar-2018 EJD343 Yes High Rssi on Cell B Traffic issue
20-Mar-2018 HJD816 Yes High Rssi Cell A&B
20-Mar-2018 GJD816 Yes High Rssi Cell A&B
20-Mar-2018 EJD816 Yes High Rssi Cell A/B/C
20-Mar-2018 TJD816 Yes High Rssi Cell A/B/C
20-Mar-2018 XJD816 No High Rssi Cell A&C
21-Mar-2018 GNJ190 Yes High Rssi
21-Mar-2018 TNJ190 Yes High Rssi Cell on all cells
21-Mar-2018 XNJ190 Yes High Rssi Cell on Cell B&C
21-Mar-2018 GNJ576 Yes High Rssi
21-Mar-2018 T/ENJ526 No High Rssi /Traffic issue
21-Mar-2018 GNJ707 No Traffiic issue , CSSR ,CS issues
21-Mar-2018 HJD175 No High Rssi , Vswr 0 on Cell B
22-Mar-2018 HJD898 Yes High vswr Cell B
22-Mar-2018 EJD902 No High Rssi Cell B
22-Mar-2018 XJD898 No High Rssi Cell A&C
24-Mar-2018 HJD250 Yes High Rssi Cell A
24-Mar-2018 TJD250 Yes High Rssi Cell A
24-Mar-2018 XJD250 Yes High Rssi Cell A&C
24-Mar-2018 TNJ236 Yes High Rssi Cell C
24-Mar-2018 XNJ236 Yes High Rssi Cell B
24-Mar-2018 ZMK309 No high Rssi
25-Mar-2018 COW754 No L2100 Cell disabled
26-Mar-2018 TJD303 No High Rssi all Cells
26-Mar-2018 EJD303 Yes High Rssi
26-Mar-2018 TJD873 No High Rssi Cell C /G
26-Mar-2018 GJD873 No Alarm ,RET issue
27-Mar-2018 GJD829 Yes Rssi /Delta issue Cell B/C
27-Mar-2018 EJD829 Yes L1800 Traffic issue on all cells
27-Mar-2018 FJD829 No L2100 Cell B/C High Rssi
28-Mar-2018 GNJ707 No Alarm /LTE1800 RET disabled
04-Apr-2018 GNJ661 Yes RSSI /Traffic issue
07-Apr-2018 ZNJ673 Yes Radio X reciver
07-Apr-2018 ZNJ305 Yes Radio X reciver
07-Apr-2018 GJD021 Yes packets lost alarm
08-Apr-2018 ZJD649 Yes packets lost alarm
08-Apr-2018 ENJ334 Yes Ret alarm
09-Apr-2018 ZNJ320 Yes Radio X reciver
10-Apr-2018 ENJ145 Yes Disconnected alarm
10-Apr-2018 ZJD952 Yes No connection alarm
10-Apr-2018 ZNJ160 Yes Sec A&C Down
15-Apr-2018 ZJD054 Yes Vswr alarm
16-Apr-2018 ZNJ934 Yes Vswr alarm
16-Apr-2018 ZNJ299 No Vswr alarm
18-Apr-2018 ZJD873 No L700 cell Locked
18-Apr-2018 ENJ190 yes Vswr high
18-Apr-2018 ZNJ299 yes Radio X reciver
19-Apr-2018 ENJ128 Yes vswr High
19-Apr-2018 ZNJ041 No SFP not present
19-Apr-2018 ZNJ112 YES SIU/TCU alarm
19-Apr-2018 ZNJ316 YES Radio X reciver
21-Apr-2018 ZNJ041 No SFP not present L2100 MSMM
21-Apr-2018 ZNJ316 YES Radio X reciver
21-Apr-2018 XJD275 No vswr high
21-Apr-2018 ZNJ320 YES Radio X reciver
21-Apr-2018 ZNJ204 No Sector B/F Down
22-Apr-2018 ZJD007 Yes Radio X reciver
22-Apr-2018 ZJD744 yes vswr high
22-Apr-2018 E/FJD043 Yes Site down
23-Apr-2018 ZNJ709 Yes Radio X reciver
23-Apr-2018 ZJD850 Yes vswr High
23-Apr-2018 ZNJ086 Yes vswr High
24-Apr-2018 TNJ784 Yes vswr High
24-Apr-2018 ZNJ077 Yes Radio X reciver
24-Apr-2018 ZNJ586 Yes Rx Path /RX Diversity
25-Apr-2018 ZJD937 Yes Rx Path /RX Diversity
25-Apr-2018 ENJ547 No No connection alarm
25-Apr-2018 ZNJ547 Yes Radio X reciver
26-Apr-2018 ENJ086 Yes vswr High
26-Apr-2018 HJD744 No cell A&E Down
28-Apr-2018 ZNJ747 Yes Radio X reciver
28-Apr-2018 ZJD913 Yes Radio X reciver
28-Apr-2018 ZNJ300 Yes Radio X reciver
28-Apr-2018 ZNJ097 Yes Radio X reciver
29-Apr-2018 ZJD091 Yes High RSSI , S2 ret disabled , u900 rssi high
29-Apr-2018 ZNJ358 Yes u900 swap A&C
30-Apr-2018 ENJ150 Yes VSWR High
30-Apr-2018 ZJD547 Yes Rx Path /RX Diversity
30-Apr-2018 FNJ043 Yes L700 S1 Down
01-May-2018 ZNJ683 Yes Radio X reciver
01-May-2018 ZNJ125 Yes Radio X reciver
01-May-2018 HJD848 Yes Rssi High
01-May-2018 GJD848 Yes Rssi High
02-May-2018 ZNJ747 Yes Rx Path /RX Diversity
02-May-2018 ZNJ300 Yes Rx Path /RX Diversity
03-May-2018 ZNJ076 Yes Rx Path /RX Diversity
03-May-2018 ENJ150 Yes VSWR High
03-May-2018 ENJ651 Yes VSWR High
03-May-2018 FNJ043 Yes L700 S1 Down
03-May-2018 ENJ010 No No connection alarm
05-May-2018 ZNJ125 Yes Radio X reciver
05-May-2018 ZNJ747 Yes Radio X reciver
05-May-2018 ZNJ705 No RET Alrm
06-May-2018 ZNJ160 Yes Radio X reciver
06-May-2018 ZNJ021 Yes Rx Path /RX Diversity
06-May-2018 ZJD708 Yes Radio X reciver
07-May-2018 ZNJ150 Yes Rx Path /RX Diversity
07-May-2018 ZNJ164 Yes Rx Path /RX Diversity
07-May-2018 ZNJ087 Yes Radio X reciver
07-May-2018 HJD744 No 1st sec Fiber wronly connected or
configuration issue
08-May-2018 ZNJ175 Yes Rx Path /RX Diversity
08-May-2018 GNJ175 Yes Node slow login to integration team
09-May-2018 ZNJ300 yes Radio X reciver
09-May-2018 ZNJ150 yes Radio X reciver
09-May-2018 TNJ705 No RET Disabled
09-May-2018 GNJ674 yes RET Disabled
12-May-2018 ZNJ125 yes Radio X reciver
12-May-2018 ZNJ709 yes Radio X reciver
12-May-2018 ZNJ747 yes Radio X reciver
12-May-2018 GNJ021 yes RET Disabled
12-May-2018 TNJ705 No RET Disabled
13-May-2018 HNJ150 No High Rssi sec 1
13-May-2018 GNJ150 No High Rssi
14-May-2018 ZNJ125 yes Radio X reciver
14-May-2018 TNJ757 yes Cell C is down
14-May-2018 ENJ279 yes No connection alarm
14-May-2018 ZJD744 yes Hardware and IDB inconsist alarm
14-May-2018 HJD744 No Cell A is down due to hardware
15-May-2018 ZNJ150 yes Rx Path /RX Diversity
18-May-2018 ZNJ709 yes Rx Path /RX Diversity
18-May-2018 ZJD744 yes Hardware and IDB inconsist alarm
18-May-2018 ZJD121 yes Rx Path /RX Diversity
20-May-2018 GJD121 No RET Disabled
20-May-2018 EJD541 No vswr high
20-May-2018 ZNJ709 yes Rx Path /RX Diversity
21-May-2018 EJD541 No vswr high
21-May-2018 ZNJ150 yes Rx Path /RX Diversity
21-May-2018 ZNJ709 yes Rx Path /RX Diversity
22-May-2018 ZJD975 yes L700 B&C swap
22-May-2018 GJD913 yes Sec 1,3 high rssi
22-May-2018 TJD913 yes Sec 3 high rssi
22-May-2018 ZJD192 yes L700 A&B swap
22-May-2018 ZNJ583 No Need to check complete HC
23-May-2018 ZJD833 yes U900 1st sec Rssi
TJD913 KPI issue and Degration issue , U900
23-May-2018 ZJD913 yes 1st /3rd sec Rssi and Delte
23-May-2018 ZNJ195 No TNJ195C poor rssi
23-May-2018 ZNJ992 Yes U900-Rssi S3 , U2100 F1 -F2 swap
23-May-2018 ZNJ992 YES High Rssi Issue
26-May-2018 TNJ787 No Sec A&E down
26-May-2018 TNJ467 No High Rssi B/C sectors
26-May-2018 ZNJ971 No High Rssi
27-May-2018 ZJD928 YES Radio X reciver
27-May-2018 TNJ467 No Sec A&E down
28-May-2018 ZJD701 No U900 high Rssi and need to check complete
HC
28-May-2018 ZNJ787 No Sec A&E down
28-May-2018 ZNJ174 No FNJ174 Rssi ,U900 Rssi
28-May-2018 ZJD284 No Cell E/F/G down due to HW
29-May-2018 ZNJ787 No Sec A&E down
29-May-2018 ZNJ538 No Number of HW Missmatch with SUP/SCU
29-May-2018 ZJD928 YES Radio X reciver
29-May-2018 TNJ467 No Vswr issue
U900 high Rssi and need to check complete
30-May-2018 ZJD701 No HC
30-May-2018 ZNJ174 yES FNJ174 Rssi ,U900 Rssi
30-May-2018 ZJD929 YES F/T JD 929 Rssi
30-May-2018 ZNJ671 No RSSI issue
30-May-2018 ZNJ833 No U900 1st sec Rssi
01-Jun-2018 ZNJ184 Yes RSSI issue
01-Jun-2018 EJD929 Yes Vswr issue
01-Jun-2018 HNJ929 Yes RSSI issue
02-Jun-2018 ZNJ184 Yes Rx Path /RX Diversity
02-Jun-2018 E/HNJ929 Yes High Rssi /U900 Vswr
02-Jun-2018 ZJD833 No Rx Path /RX Diversity
04-Jun-2018 ZNJ179 Yes Rx Path /RX Diversity
04-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
05-Jun-2018 ZJD209 No RET Disabled
05-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
05-Jun-2018 ZJD488 No HW alarm
05-Jun-2018 ZJD717 No High Rssi
06-Jun-2018 ZJD275 No Cell is in sleeping mode and vswr
06-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
06-Jun-2018 EJD209 No RET Disabled
06-Jun-2018 HNJ833 No No connection alarm
06-Jun-2018 XJD275 No Cell is in sleeping mode and vswr
06-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
09-Jun-2018 HJD717 No High Rssi
09-Jun-2018 EJD209 No RET Disabled
09-Jun-2018 HNJ833 No No connection alarm
09-Jun-2018 XJD275 No Cell is in sleeping mode and vswr
09-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
10-Jun-2018 ZNJ410 Yes Cell b down
10-Jun-2018 ZNJ705 No G/HNJ705 DCR since Availabilty issue
10-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
11-Jun-2018 ZNJ145 yes Enclouser data miss match
11-Jun-2018 ZNJ088 yes Rx Path /RX Diversity
11-Jun-2018 ZNJ130 yes Enclouser data miss match
11-Jun-2018 ZNJ088 yes Rx Path /RX Diversity
12-Jun-2018 ZNJ224 yes Rx Path /RX Diversity
12-Jun-2018 ZNJ088 yes Rx Path /RX Diversity
18-Jun-2018 ZJD415 yes environment
18-Jun-2018 ZNJ150 No sector D down
19-Jun-2018 ZJE029 No 2G intermitted down
19-Jun-2018 ZNJ088 yes Rx Path /RX Diversity
20-Jun-2018 ENJ717 No Degradation alarm on all Cells
20-Jun-2018 XJD275 No RRU is in sleeping mode ,vswr high
20-Jun-2018 ZJD493 No Main failure alarm
21-Jun-2018 ZNJ088 Yes Rx Path /RX Diversity
21-Jun-2018 EJD717 Yes Degradation alarm on all Cells
21-Jun-2018 XNJ095 No RRU is in sleeping mode ,vswr high
21-Jun-2018 ZNJ547 No MOIM issue on sector 1
23-Jun-2018 EJD827 Yes No connection alarm
23-Jun-2018 TNJ538 Yes No connection alarm
24-Jun-2018 EJD717 Yes No connection alarm
25-Jun-2018 TNJ085 Yes No connection alarm
25-Jun-2018 ENJ/TNJ220 No No connection alarm
25-Jun-2018 TJD015 No Low power in SFP
26-Jun-2018 GJD019 Yes Site down
26-Jun-2018 HJD409 Yes High Rssi
26-Jun-2018 HJD833 Yes High Rssi /Delta
26-Jun-2018 ZNJ092 Yes Rx Path /RX Diversity
27-Jun-2018 G/TNJ467 No Rssi issue and Drops /vswr
27-Jun-2018 GJD937 Yes Site down
28-Jun-2018 ENJ220 Yes No connection alarm
28-Jun-2018 ZNJ547 Yes Rx Path /RX Diversity
28-Jun-2018 ZNJ781 No Rx Path /RX Diversity
30-Jun-2018 ENJ220 No No connection alarm
30-Jun-2018 ZNJ794 Yes Rx Path /RX Diversity
30-Jun-2018 ZNJ086 Yes Rx Path /RX Diversity
01-Jul-2018 ZJD121 No Rx Path /RX Diversity
01-Jul-2018 H/ZJD178 Yes Sites are down
01-Jul-2018 ENJ547 Yes TMA disabled
02-Jul-2018 ZNJ794 Yes Rx Path /RX Diversity
02-Jul-2018 ZNJ781 No Rx Path /RX Diversity
02-Jul-2018 ZJD601 No Performance issue
03-Jul-2018 ZNJ097 Yes Rx Path /RX Diversity
03-Jul-2018 HNJ659 yes RSSI ISSUE
03-Jul-2018 ENJ659 Yes No connection alarm
03-Jul-2018 ZNJ659 Yes Rx Path /RX Diversity
04-Jul-2018 ZNJ097 Yes Rx Path /RX Diversity
04-Jul-2018 Z/H/ENJ659 Yes Site down
05-Jul-2018 HJD701 Yes Rssi /Delta issue
05-Jul-2018 HJD601 No Performance issue
07-Jul-2018 EJD881 Yes High Rssi /Traffic issue
07-Jul-2018 XJD881 Yes High Rssi /Traffic issue
07-Jul-2018 TJD881 Yes High Rssi /Traffic issue
08-Jul-2018 TNJ252 No High Rssi /Vswr
09-Jul-2018 ZNJ233 No Main failure alarm
09-Jul-2018 ZJD654 Yes Rx Path /RX Diversity
09-Jul-2018 ZNJ299 Yes Rx Path /RX Diversity
10-Jul-2018 ZJD325 YES Rx Path /RX Diversity
10-Jul-2018 XJD275 No RRU is in sleeping mode ,vswr high
10-Jul-2018 XJD095 No RRU is in sleeping mode ,vswr high
10-Jul-2018 TNJ145 No No connection alarm
11-Jul-2018 TNJ264 YES RET issue
12-Jul-2018 GJD909 yES Site down
12-Jul-2018 EJD909 No No connection alarm
12-Jul-2018 ZJD547 No Battery discharge alarm
14-Jul-2018 XNJ095 No RRU is in sleeping mode ,vswr high
14-Jul-2018 XJD275 No vswr high
15-Jul-2018 Z/H/E/TJD092 YES
15-Jul-2018 Z/H/E/TNJ964 YES
16-Jul-2018 TNJ083 YES RSSI ISSUE
16-Jul-2018 TNJ110 YES RSSI ISSUE
16-Jul-2018 TNJ128 YES RSSI ISSUE
16-Jul-2018 TNJ326 YES RSSI ISSUE
17-Jul-2018 TNJ496 YES RSSI ISSUE
17-Jul-2018 TNJ800 YES RSSI ISSUE
17-Jul-2018 TNJ905 YES RSSI ISSUE
17-Jul-2018 TNJ799 No RSSI ISSUE
17-Jul-2018 TNJ992 YES RSSI ISSUE
19-Jul-2018 GJD638 No Loss of Sync
19-Jul-2018 TNJ309 yes No connection alarm
19-Jul-2018 HNJ432 yes Delta high
19-Jul-2018 HNJ800 yes Delta high
19-Jul-2018 HNJ211 No Delta high
21-Jul-2018 HNJ165 Yes Delta high
21-Jul-2018 HNJ252 No RSSI Issue /RET diabled
23-Jul-2018 XJD671 Yes Site down
27-Jul-2018 TNJ309 No No connection alarm
29-Jul-2018 ZNJ309 Yes Rx Path /RX Diversity
29-Jul-2018 ZNJ397 Yes Rx Path /RX Diversity
29-Jul-2018 ENJ309 No No connection alarm
30-Jul-2018 ZNJ309 Yes Rx Path /RX Diversity
30-Jul-2018 ZNJ397 Yes Rx Path /RX Diversity
01-Aug-2018 GNJ372 Yes RSSI /Detla Issue
01-Aug-2018 ZNJ397 Yes Rx Path /RX Diversity
07-Aug-2018 ZNJ086 Yes Rx Path /RX Diversity
09-Aug-2018 ZNJ086 Yes Rx Path /RX Diversity
Resolution

Reloaded new IDB provided by integrator then alarm cleared


Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
before troubleshoot alarm was on S1 we swapped S1 RET cable with S2 alarm shifted to S2 we found
that issue is in RET cable
No any alarm was active
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
Indoor jumpers cables was bend
Indoor jumpers cables was bend ,retighted indoor jumpers cables , swapped RET cable with other
sector after these troubleshoot alarm cleared
Alarm was already cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
NA
Alarm was already cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
Reloaded new IDB provided by integrator then alarm cleared
during troubleshooting we found that 3G jumpers was swapped +/- after changed TMA port jumper
cable +/- alarm cleared
NA
NA
NA
changed alarm polarity
Swapped indoor /outddoor SFP module with other sector after swap alarm cleared
changed alarm polarity
swapped outdoor jumper cables with other sectors after swap alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
NA
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
After removed sector swap between B &C alarm cleared
some dummy Rets was defined in LTE1800 after cordinate with integration team he delete dummy rets
we swapped TMA /RET cables and RUS after that
with alarm
other cleared
sector but alarm reappeared on sec#3 we found
that issue is in antena
Need to replace RET cable 2week before I visited this site c
Defined BFU in IDB , checked and Retighted battery backup connection after this alarm cleared
Alarm was already cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
retighted indoor jumpers cables after this alarm cleared
NA
NA
after cordinate with integrator he delete dummy RETs alarm cleared because RETs was already defined
in 3G
reconfigured alarm in IDB after this alarm cleared
reconfigured alarm in IDB after this alarm cleared
reconfigured alarm in IDB after this alarm cleared
NA
Alarm was already cleared
battery backup cabinate door was open after close door alarm cleared
NA
after toubleshoot we found TMA need to replace because before alarm was on 2nd sec when we
swapped TMA with 1st sec alarm shifted to 1st sec
NA
We swapped TMA/Jumpers cables and RUS with other sector after this alarm cleared
NA
Alarm was already cleared
we remaked indoor /outdoor jumper cables connectors , we checked sectors cables one by one there
was no any swap in sectors
we checked sectors cables one by one there was no any swap in sectors
we remaked indoor /outdoor jumper cables connectors , we checked sectors cables one by one there
was no any
after troubleshoot we found issue at integrator swap
end we in sectorsall information about sectors antena to
provide
integration team after that they reconfigured Rets after this alarm cleared
NA
No any alarm was active
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
after reload IDB alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
During troubleshoot we found that fiber cable is faulty before alarm was on Sec3 after swap fiber cable
During troubleshoot we found thatwith
SFPsec2 alarm
module is shifted to sec 2alarm was on Sec1 after swap SFP
faulty before
module with sec2 alarm shifted to sec 2 in both baseband SFP module type is different
Rssi was alredy good
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Complete site was down power issue on site
Alarm cleared after when we closed cabinate door
NA
before alarm was on 2nd sec we swapped RUS of 2nd sec with 1st sec and integration team reload TG
Alarm was already cleared no any swapped thenfound
alarm and
cleared
after retighted jumpers and connector ICM
values cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
alarm was alredy cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Defined BFU in IDB , checked and Retighted battery backup connection and repluged Battery sensor
cable after this alarm cleared
Alarm was already cleared
Alarm was already cleared
NA
NA
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
NA
NA
we remaked indoor /outoor IF cable connectors , cold restart NE /FE MMUs Checked Link configuration
after troubleshoot still alarm not clear fluctuation on Low modulation
Aalrm was already cleared
we checked all jumpers cables connection , we provide serial number of antenas to integration team
after reconfigure alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
NA
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Retighted indoor/outdoor jumpers cables after this alarm cleared
Retighted indoor/outdoor jumpers cables after this Rssi issue solved
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Retighted outdoor jumpers cables after this alarm cleared
Removed swapped betwwen B&C
Need to replace RET cable before I visited this site
NA
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
alarm was already cleared
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Power issue on site working on only on fhase due to low voltages alarm is active ,one phase AC cable
joint is sparked inside generator
after troubleshoot we found that antena intena internal RET is faulty
fence gate was locked and some problem is in lock we tried but failed to open gate lock due to this
troubleshoot was not possible
Reloaded new IDB with new values of TMA / feeder and loss after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
we checked all jumpers cables connection every thing is ok on site
NA
during troubleshoot we found issue in ret cable need to replace ret cable but ret cable is not available
in wherhouse
Alarm was already cleared
Before alarm was on DUG-1800 3rd secB We swapped RUS ,Jumper cable ,Feeder cable with DUG-2
Before alarm was on DUG-1 2nd 3rd secWe
secA A after this alarm
swapped cleared cable ,Feeder cable with DUG-2
RUS ,Jumper
2ndsec B after this alarm cleared
Redefined PSU detail in IDB after this alarm cleared
NA
NA
removed swapped betwwen A&B
We remked indoor jumper cables connectors , swapped jumper cables with other sectors after this
alarm cleared
During troublsooting we found sectors are swap B&C we removed swap
During troublsooting after reconfigure
we found issue inRETs
L700byRRUintegration team alarm
, RRU is power off wecleared
swapped Power cable /fiber
cable with other sector RRU on other sector these power /fiber are working but good sector power
/fiber arefiber
After reconnect not working herecleared
cables alarm
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
On site RETs are defined in U900 ,site is alarm free but as per integration team they will shift RETs to 3G
in this condition Spare requried (RETs cables )
After reload CV and software reset to SUP alarm cleared
Alarm was already cleared
After reload CV and software reset to SUP alarm cleared
Before Troubleshoot TMA was disabled after swap TMA with other sector alarm cleared and TMA
enabled
NA
Retighted outdoor jumpers cables after this alarm cleared
After hard reset DUW alarm was cleared
Generator was off site was working on battery backup and batteries voltage was low due to this alarm
was active
NA
After cordinate with integrator they delete RETs and reconfigured RETs after this alarm cleared
After reconfigure Alarm in IDB alarm cleared
on site we found issue in RUS-6 fault alarm was on RUS-6 we swapped RUS-6 with RUS-5 after this
On site EC port alarm was active after cordinatealarm cleared
with integration team they define new EC port on SCU
after this alarm cleared
RET cable faulty
After replug fiber cable alarm cleared
Alarm was already cleared
After reload CV and software reset to SUP alarm cleared
After clean and replug SFP module alarm cleared
After cordinate with integrator they configure SUP after this alarm cleared
NA
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After cordinate with integrator they delete RETs and reconfigured RETs after this alarm cleared
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Alarm was cleared
After cordinate with integrator they delete RETs and reconfigured RETs after this alarm cleared
After cordinate with integrator they delete RETs and reconfigured RETs after this alarm cleared
We checked RRU /power /fiber every thing was ok we found issue in power breaker of RRU in power
cabinate need to replace power breaker
After retightened indoor connectors Rssi was in range
we swapped Fiber cable F1/F2 -A&B cells
NA
We checked feeder cable one by top to bottom we removed feeder swap Cell A&B
Retightened indoor/outdoor jumpers cables after this alarm cleared
Retightened indoor jumpers cables after this alarm cleared
Retightened indoor/outdoor jumpers cables after this alarm cleared
we checked all outdoor jumper cables connections every thing was ok but still alarm is present as per
integration team issue is in Internal RET need to replace Antena
After hard reset DUW alarm was cleared
After cordinate with integrator repluged RUS data cables correctly reloaded new IDB after this alarm
cleared
After retightened outdoor connectors Rssi was in range and no any Erab drop found
Alarm was already cleared
we replaced outdoor jumper cables , swapped RRU /Fiber cable with other good sector but still all
active on same sector we found issue in antena port
NA
Alarm was already cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after
this alarm cleared
we checked sector wise fiber cables one by one and we found swap in sector we removed swap
For RETs we found swap in sectors after clear swap Rets came up , Retightened indoor/outdoor
jumpers cables after this alarm cleared
Alarm was already cleared
Alarm was already cleared
After Retightened indoor/outdoor jumpers cables after this alarm cleared
After Retightened indoor/outdoor jumpers cables after this alarm cleared
NA
After Retightened indoor/outdoor jumpers cables after this alarm cleared
Swap removed but still DT remaining due to alarm on 2G
Swap removed but still DT remaining due to alarm on L1800
Swap removed
Swap removed
Swap removed
Swap removed
Swap removed
Swap removed
Swap removed
Swap removed
Swap removed
NA
swap removed
swap removed
NA
swap removed
NA
swap removed
swap removed
swap removed
swap removed L1800 , 2G 900 Still swap
swap removed
NA
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
NA
NA
swap removed
swap removed
swap removed
swap removed
NA
swap removed
swap removed
swap removed
swap removed
NA
swap removed
swap removed
swap removed
swap removed
swap removed
NA
we checked all feeder cables one by one we found swap in sectors cables we removed swap and
complete health checked after this site was alarm free
Alarm was already cleared
Alarm was already cleared
on site still old antennas are working L700 RETs areNA not defined we checked every thing related rssi
issue but rssi still same as before as per Integration team first he will define RETs then need to
troubleshoot but on site RETs are not available so need RETs cables for all sectors
NA
swap removed
swap removed
swap removed
swap removed
swap removed
NA
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
swap removed
After retightened outdoor jumpers cable connectors Rssi become normal and no any Erab drop found
After retightened indoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
we checked some outoor jumpers are banded and power cables are tied with jumper cables after
saprate power cables with jumpers rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened outdoor jumpers cable connectors Rssi become normal after this no any traffic
issue found
After hard reset and HC rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
we checked all feeder cables one by one we found swap in cable connectios on antenna end between
TDD/FDD
we checked we removed
all feeder swap
cables one byand
onecomplete
we foundhealth checked
swap in after this rssi
cable connectios onbecome
antennanormal
end between
TDD/FDD we removed swap and complete health checked after this rssi become normal
we checked everything related rssi issue but still rssi is bad on cell B&C
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
NA
we found issue in RUS RX port of RUS is faulty need to replace RUS
Rssi /Delta issue resolved after troubleshooting but vswr still 0 showing we swapped RUS with other
sector same issue shifted there
we remaked outdoor feeder connectors after this vswr become normal
we checked everything related rssi issues we checked connections ,swapped jumpers cables, checked
Azimuth , checked M tilts but still rssi is bad on cell C
we checked everything related rssi issues we checked connections ,swapped jumpers cables, checked
Azimuth , checked M tilts but still rssi is bad on cell A&C
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
we checked everything related rssi issues we checked connections ,swapped jumpers cables, checked
we checked Azimuth , checked
everything related M
rssitilts after
issues wethat integration
checked team said
connections you can
,swapped leave site
jumpers cables, checked
Azimuth , checked M tilts after that integration team said you can
we checked everything related rssi issues we checked connections ,swapped jumpers leave site
cables, checked
Azimuth , checked M tilts after that integration team said you can leave site
we checked everything related rssi issues we checked connections ,swapped jumpers cables, checked
Azimuth , checked M tilts after that integration team said you can leave site
NA
NA in connections of FDD/TDD on all sectors we
we checked antenna connections ,we found swap
removed swap , checked azimuths, we swapped jumpers cables with other sectors but still bad rssi on
Cell C other cell rssi
After retightened and replug indoor/outdoor become
jumper cablesnormal
connectors Rssi become normal
we checked antenna connections ,checked azimuths, we swapped jumpers cables with other sectors
but still bad rssi suspected antenna issue
we checked antenna connections everything is ok onsite but still alarm is active and LTE2300 /LTE1800
RETs are disable suspected antenna issue
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
wechecked
we checkedeverything
all connections ,checked
related antenna
rssi issues of sectorport2connection
,3 we checked , weall
found some connectors
connections loose
indoor a nd we
outdoor
retighened connectors
antenna port correct ports are used ,swapped jumpers cables outdoor and indoor with other good
we checked
sector 1 , we antenna
swappedconnections
RUS /TMA with /portother
connection , we swapped
good sector 1 , checked complete
Azimuth3G 3rd sector
, checked M with 2nd
tilts after
sector integration team reconfigured RETs , we checked and
that still rssi only 4dbm increase swapped LTE1800 jumpers with other
sector after all troubleshooting alarm shift from 3rd sector to 2nd sector and 3rd sector become
we checked antenna connections /port
normal we foundconnection , we
issue in swapped
antenna complete
internal RET 2nd sector jumper cables
with 3rd sector ,we correct azimuths of antennas after all this troubleshooting rssi become normal
Alarm was already cleared
Alarm was already cleared
After replug-in and plugout transmission LAN cables or swapp with other technology alarm cleared
After repluged Transmission LAN cable alarm cleared
After reconfigure RET profile by integration team alarm cleared
After reload IDB with correct parameter alarm cleared
After reconfigure Hub position of DUS alarm cleared
Alarm was already cleared
Alarm was already cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
we swapped RRU, Jumpers cables , fiber cables with other sector alarm still there suspected antenna
port issue
L700 cells down due to L700 RRU still not power on extra breaker not available on site for L700 RRU
After remaked outood feeder connector alarm cleared
After reload IDB with correct parameter alarm cleared
After remaked outood feeder connector alarm cleared
L700 cells down due to still L700 rru fiber cables not plugged-in in baseband R503 and also SFP module
missing
After Hard reset TCU alarm cleared
After reload IDB with correct parameter alarm cleared
L700 cells down due to still L700 rru fiber cables not plugged-in in baseband R503 and also SFP module
missing
After reload IDB with correct parameter alarm cleared
We swapped RRU, Jumpers cables , fiber cables with other sector alarm still there suspected antenna
port issue
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
after clean and replug jumper cables alarm cleared
alarm was cleard
After reload IDB with correct parameter alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
we checked cable connections indoor /outdoor we swapped TMA of 2nd and 3rd sec with 1st sec but
still alarm not resolved
After reload IDB with correct parameter alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
we found swap in sectors and technologies we tried to clear issue but still alarm not cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal , after
After swaputened and replug indoor/outdoorthat alarm
jumpercleared
cables connectors Swap become normal , and
ret reconfigured by integration team after that alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After reload IDB with correct parameter alarm cleared
alarm was cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
Alarm was cleared
NA
After reload IDB with correct parameter alarm cleared
After reload IDB with correct parameter alarm cleared
On site for LTE2300 new antennas are working and no any RET cable connection with new antennas
other all technologies are working on old antennas due to this LTE 2300 RETs are disbaled
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
we found RRU issue on site we swapped RRU/fiber cable ,SFP module with other sector alarm swapped
on other sector
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After reconfigured port for 3G on TCU after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After swapped ret cable with other sector and replug ret cable after that alarm cleared
After swapped ret cable with other sector and replug ret cable after that alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After swapped ret cable with other sector and replug ret cable after that alarm cleared
On site for LTE2300 new antennas are working and no any RET cable connection with new antennas
other all technologies arerssi
working
issueson
weold antennas due to this,swapped
LTE 2300jumpers
RETs arecables,
disbaled
we checked everything related checked connections checked
Azimuth , checked M tilts but still rssi is high
we checked everything related rssi issues we checked connections ,swapped jumpers cables, checked
Azimuth , checked M tilts but still rssi is high
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared

After swapped TMA with other sector alarm cleared


Reloaded new IDB after checked hadware detail after this alarm cleared
we found RRU issue on site we swapped RRU/fiber cable ,SFP module with other sector alarm swapped
on other sector
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB after checked hadware detail after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After swapped ret cable with other sector and replug ret cable after that alarm cleared
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
after trace cables we found sawpped in sectors after this we removed swapped
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
rssi becomes normal
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
rssi becomes normal
after trace cables we found sawpped in sectors after this we removed swapped
NA
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
we checked everything related rssi issuesrssi
webecomes
checked normal
connections ,swapped jumpers cables after this
rssi becomes normal
NA
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
we checked everything related rssi issuesrssi
webecomes
checked normal
connections ,swapped jumpers cables after this
rssi becomes normal
NA
NA
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
NA
NA
NA
NA
on site we found issue in fiber , fiber cables are faulty bad condition of 2 sectors fiber cables
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
NA
NA
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
rssi becomes normal
NA
NA
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
After replace outdoor jumper cable alarm clared
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After retightened and replug indoor/outdoor jumper cables connectors Rssi become normal
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
On site only LTE1800 working on new antennas and still no RET connection with antenna this issue
will remain untill all technologies shif
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
alarm was already cleared
NA
on site we found issue in rru , before alarm was in sector 2 after swap rru with sector 1 alarm shifted
need to replace L700 RRU on 1st sector
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
On site only LTE1800 working on new antennas and still no RET connection with antenna this issue
will remain untill all technologies shif
NA
on site we found issue in rru , before alarm was in sector 2 after swap rru with sector 1 alarm shifted
need to replace L700 RRU on 1st sector
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
On site only LTE1800 working on new antennas and still no RET connection with antenna this issue
will remain untill all technologies shif
NA
on site we found issue in rru , before alarm was in sector 2 after swap rru with sector 1 alarm shifted
need to replace L700 RRU on 1st sector
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
alarm was cleared
na
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
after cordinate with integration team alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
after cordinate with integration team alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
after hard rest DUG alarm cleared
Sector D not available on site
we found issue is DUG nned to replace DUG
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
issue at integration team end and he will clear after recive TCN as he agreed
on site we found issue in rru , before alarm was in sector 2 after swap rru with sector 1 alarm shifted
main failure alarm active we Done need
allto
troubleshooting
replace L700 RRU
but on
still1st
alarm
sector
is active site working on genset on
site every thing is ok I checked all PSU all are ok ,hardreset DUG ,checked external alarms ,Swapped
PSU on other slots now After
nothing remaining,
replace outdoorchecked
jumperhardware
cable alarm detail in IDB but still alarm active
clared
after cordinate with integration team integration team cleared alarm
we swapped RRU, Jumpers cables , fiber cables with other sector alarm still there after this tro we left
on site Isite because
checked implemention
in group team reached
as per integration teamononsite
issueheon said
sitehewe
will dosite
left troubleshooting
after some time they
again reply in group issue still at site
after cordinate with integration team integration team cleared alarm
after cordinate with integration team integration team cleared alarm
after cordinate with integration team integration team cleared alarm
after cordinate with integration team integration team cleared alarm
after cordinate with integration team integration team cleared alarm
after cordinate with integration team integration team cleared alarm
After hard reset DUW alarm was cleared
After remaked outdoor feeder connector and swapped jumpers cables with other sector alarm cleared
After retigned indoor / outdoor feeder connector and swapped jumpers cables with other sector
alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
After hard reset DUW alarm was cleared
after cordinate with integration team integration team cleared alarm
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
Suspected SUP EC port issue at site confirm by integration team need to replace SUP
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After hardrest DUW /DUG site become up
We found swap in sector cables after clear swap alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
NA
Key was not available at seeder E&M office
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
rssi becomes normal
after cordinate with integration team integration team cleared alarm
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Alarm was cleared
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
WE DONE all possible troubleshooting stillrssiRSSI is bad normal
becomes I discussed this issue with integration team one
person his name surpatap he said due site located near airport runway mybe due to this performance
After retightened outdoor
nok,we checked
jumpers cable
every thing
connectors
related
Rssi
this
become
issue allnormal
is ok atafter
site this no any traffic
issue found
After retightened outdoor jumpers cable connectors Rssi become normal after this no any traffic
issue found
After retightened outdoor jumpers cable connectors Rssi become normal after this no any traffic
issue found
NA
NA
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
on site we found issue in rru , before alarm was in sector 2 after swap rru with sector 1 alarm shifted
need to replace L700 RRU on 1st sector
we swapped RRU, Jumpers cables , fiber cables with other sector alarm still there after this tro we left
site because implemention team reached on site he said he will do troubleshooting
NA
We traced RET cables one by/one , SWAPPED RET cables,we trace fiber cables of sec 1 carrier one
/carrier 2 not found any cable swap , checked all jumper connection RRU end antenna end at last
integration team said leave site
alarm if you
was not found any cabling swap
cleared
NA
NA
We swapped RRU, Jumpers cables , fiber cables with other sector alarm still there suspected RRU issue
We swapped RRU, Jumpers cables , fiber cables with other sector alarm still there suspected antenna
port issue
Alarm was already cleared
Alarm was already cleared
Alarm was already cleared
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
we checked everything related rssi issuesrssiwebecomes
checked normal
connections ,swapped jumpers cables after this
rssi becomes normal
After retightened outdoor jumpers cable connectors Rssi become normal after this no any traffic
issue foundRssi become normal after this no any traffic
After retightened outdoor jumpers cable connectors
we checked everything related rssi issues we issue found
checked connections ,swapped jumpers cables after this
rssi becomes normal
we checked everything related rssi issues we checked connections ,swapped jumpers cables after this
rssi becomes normal
NA
After retightened outdoor jumpers cable connectors Rssi become normal after this no any traffic
issue found
NA
after cordinate with integration team integration team cleared alarm
After retightened indoor /outdoor jumpers cable connectors delta become normal
After retightened indoor /outdoor jumpers cable connectors delta become normal
NA
After retightened indoor /outdoor jumpers cable connectors delta become normal
NA
after Hardrest Baseband site become up
Found SUP EC port faulty after cordinate with integration team Found SUP EC port faulty because
after reconfiguration of port alarm again appeared within 2min
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Found SUP EC port faulty after cordinate with integration team Found SUP EC port faulty because
after reconfiguration of port alarm again appeared within 2min
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After Replace RRU cable alarm clared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
Reloaded new IDB with new values of TMA / feeder and loss , retighted indoor jumper cables after this alarm cleared
After remaked outood feeder connector and swapped jumpers cables with other sector alarm cleared
Submitted by
Issues Comments, If any ASP
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
RET cable need to NA MOBISERVE
replace
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA Only battery power alarm was active MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA on old
Site working NA MOBISERVE
antenas TT is under NA MOBISERVE
MS
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA Rooftop key with building NA owner he have some MOBISERVE
Access issue on site issues he wants first stc clear his issues then he MOBISERVE
Access issue on site Site located inwill
VIPgive
areakey
need STC letter MOBISERVE
Site working on old as per integration team site is not in antena swap MOBISERVE
antenas list
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Rooftop key with building owner he was not
Access issue on site MOBISERVE
availabel at home
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Antena need to NA MOBISERVE
replace
Need on sec#3
to replace RET NA MOBISERVE
cabel
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located inside Saudi Aramco area need STC
Access issue on site MOBISERVE
letter
Site located inside king faisal naval Base area
Access issue on site MOBISERVE
need STC letter
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site was Down NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site located on stc
Hera international Mall for access MOBISERVE
site is rooftop and RTletter
key requried
NA NAwith building owner and MOBISERVE
Access issue on site he refused to open gate as per owner he have MOBISERVE
some issues first stc clear his issues then he will
NA opnNAgate MOBISERVE
NA NA MOBISERVE
Need jumper
NA cable NA MOBISERVE
connector NA MOBISERVE
indoo/outdoor to
NA
clear vswr alarm NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site site located on Red requried
Sea Mall for access stc letter MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Need fiber cable NA MOBISERVE
Need SFP Module NA MOBISERVE
65/2
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Building main gate was locked MOBISERVE
Access issue on site Site located in University need stc letter for access MOBISERVE
NA NA MOBISERVE
Complete site was NA MOBISERVE
down
Access issue on site Site located inside Shoaibha power plant MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located in royal guard compound Need stc
Access issue on site MOBISERVE
letter
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA Need RET Cable MOBISERVE
Access issue on site Site located inside port need stc letter MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA Need to replace Antena on sec#3 MOBISERVE
NA NA MOBISERVE

NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site site is rooftop to access site need stc letter site MOBISERVE
located rooftop of red sea mall
NA Need RET Cable MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located inside Amercian international
Access issue on site MOBISERVE
schoolinside
Site located ,Needshoaibha
stc letterpower
for access
plant need
Access issue on site MOBISERVE
access letter or stc card for access
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Need Spare Need to replace RRU on sec #2 L700 MOBISERVE
NA NA MOBISERVE
On tower equipment Need Crane for outdoor work MOBISERVE
was far
NA NA MOBISERVE
NA NA MOBISERVE
Access4 issue
Need on site
RETs cales on Site located inside port area need stc letter MOBISERVE
site 4 sectors are NA MOBISERVE
working
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Need STC letter site located inside national guard MOBISERVE
compound
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Need RET cable (1) NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located inside airport terminal #1 need stc
Access issue on site MOBISERVE
letter
Site located inside for accesss
Qaidma sea port area need
Access issue on site MOBISERVE
stc letter
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site located inside king faisal naval Base area MOBISERVE
need STC letter
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
someone installed lock on site E&M will check
lock issue on site MOBISERVE
tomorrow
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Antena need to NA MOBISERVE
replace on sec#3
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Exchange site MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site is rooftop and main gate is locked MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Need site Key with E&M MOBISERVE
NA NA MOBISERVE
Access issue on site key requried site is ODU and locked MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site is rooftop and main gate is locked MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site site located inside compound stc letter requried MOBISERVE
as per security
Access issue on site site was rooftop and gate was locked MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
site located inside compound stc letter requried
Access issue on site MOBISERVE
as per security
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site site was rooftop and gate was locked MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Combination lock site was not handover to E&M on site MOBISERVE
issue combination lock no requried
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Exchange site STC card requried MOBISERVE
RET cables requried NA MOBISERVE
STC letter requried site located inside King
NA MOBISERVE
Abdullah University
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
STC letter requried site located inside King
Access issue on site MOBISERVE
Abdullah city
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access NA
issue (key NA MOBISERVE
requried someone NA MOBISERVE
changed all locked of
NA)
site NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access Issue site located inside shoaibha power plant access MOBISERVE
letter requried as per security
Site located inside crown prince palace STC letter
Access Issue MOBISERVE
requried
NA NA MOBISERVE
NA NA MOBISERVE
Antena need to NA MOBISERVE
replace on sec#3
Antena need to NA MOBISERVE
replace on sec#3
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Antena need to NA MOBISERVE
replace on sec#3
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Antena need to NA MOBISERVE
replace on sec#2
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Antenna Need to
Site isreplace
exchange for NA MOBISERVE
access STC ID NA MOBISERVE
requried
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue STC site located inside armed forces hospital MOBISERVE
letter requried
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located on Hera international Mall for access
Access issue on site MOBISERVE
stc letter requried
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
site located on saudi home owner was not
access issue MOBISERVE
available
NA MOBISERVE
site located on saudi home owner was not
NA MOBISERVE
available
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
site located on intercontinantel hotel access letter
Access issue MOBISERVE
requried
NA NA MOBISERVE
NA NA MOBISERVE
Access issue site located in nation guared compound letter MOBISERVE
requried
MOBISERVE
Access Issue Building main gate was locked MOBISERVE
Access
Access Issue
issue main Site located on RT and RT gate was locked MOBISERVE
gate of building was NA MOBISERVE
Building main gate
locked NA MOBISERVE
was locked
AntennasNAare wall NA MOBISERVE
mounted Crane
EHS issue for
saftey Hook NA MOBISERVE
requried outdoor
was not available
work NA MOBISERVE
withAccess
us Monopol
Issue site Site located on RT and RT gate was locked MOBISERVE
site locted on RT and gate was locked building
everyAccess Issuewrong
one have Haris was not available MOBISERVE
Cordinates for this MOBISERVE
site requried
Fiber cable NA MOBISERVE
Access Issue BUilding main RT gate was locked MOBISERVE
this alarm cleared
Access issue main MOBISERVE
gate of building
EHS issue was
saftey Hook NA MOBISERVE
locked
was not available NA MOBISERVE
with us Monopol site site locted on RT and gate was locked building
Access Issue MOBISERVE
Haris was not available
MOBISERVE
site locted in Prince saoud bin Abdullmehsin
Access letter requried MOBISERVE
palace
Site located inside king faisal naval Base area
Access letter requried MOBISERVE
need STC letter
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
monopolNA site tower NA MOBISERVE
ladder is unreachable NA MOBISERVE
need 5m ladder to
NA ladder
reach tower NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
site located inside king faisal Navel base need
access issue MOBISERVE
access letter
NA NA MOBISERVE
monopolNA site tower NA MOBISERVE
ladder is unreachable NA MOBISERVE
need 5m ladder to
NA ladder
reach tower NA MOBISERVE
site located inside king faisal Navel base need
access issue MOBISERVE
access letter
NA NA MOBISERVE
NA NA MOBISERVE
NA on site
access issue NA MOBISERVE
main gate to plot was NA MOBISERVE
locked
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Need to replace RRU NA MOBISERVE
(KRC161671/1)
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
site isNA
rooftop NA MOBISERVE
antennas are wall
mount and MOBISERVE
unreachable need
NA
Crane NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Need access letter site located in army area MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue at site Need access letter site located in army area MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site need stc letter MOBISERVE
Access issue on site need stc letter MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site located inside port need stc letter MOBISERVE
NA NA MOBISERVE
access issue site NA MOBISERVE
located inside army need stc letter MOBISERVE
arealocated
site need access
inside
palace letter
access letter need stc letter MOBISERVE
required
RRU Need to replace NA MOBISERVE
Antenna Need to NA MOBISERVE
replace
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Site located inside STC need stc letter for work
Access issue on site MOBISERVE
inside STC area
NA NA MOBISERVE
Site located inside compound stc letter requried
Access issue on site MOBISERVE
as per security
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
Access issue on site Site is inside STC Exchange need jeedah stc card MOBISERVE
antennas
NA are NA MOBISERVE
unreachable crane NA MOBISERVE
requried (plam tree
NA )
tower NA MOBISERVE
NA need to replace RBS6601 BFL901009/4 MOBISERVE
this alarm cleared NA MOBISERVE
this alarm cleared NA MOBISERVE
NA need to replace RBS6601 BFL901009/4 MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
NA NA MOBISERVE
21-Jun-2018 ZNJ088 cleared

21-Jun-2018 EJD717 cleared

21-Jun-2018 XNJ095 not cleared

21-Jun-2018 ZNJ547 not cleared


Rx Path /RX Diversity

Degradation alarm on all Cells

RRU is in sleeping mode ,vswr high

MOIM issue on sector 1


After replace outdoor jumper cable alarm clared

after cordinate with integration team integration team cleared alarm

we swapped RRU, Jumpers cables , fiber cables with other sector alarm still there after this tro we left site because
implemention team reached on site he said he will do troubleshooting
on site I checked in group as per integration team on issue on site we left site after some time they again reply in
group issue still at site