Documente Academic
Documente Profesional
Documente Cultură
U-HF m
Construction
1 Conductor
1 Electrolytic, stranded, annealed, bare or
tinned copper, Class 2 or Class 5
2 2 Insulation
3 XLPE
3 Inner Sheath
Halogen-free thermoplastic filler
4
or polyester tape
4 Outer Sheath
Grey or black colored, halogen-free, low smoke,
flame-retardant, polyolefine based
thermoplastic compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for power and lighting applications.
Halogen-free, flame retardant and low smoke density type cables.
2
U-HF m
0,6/1 kV Unscreened Power & Lighting Cables
3
U-HF m
0,6/1 kV Unscreened Power & Lighting Cables
4
U-HF m
0,6/1 kV Unscreened Power & Lighting Cables
5
U-HFA m EMC
Construction
1 Conductor
Electrolytic, stranded, annealed, bare
1
or tinned copper, Class 2 or Class 5
2 Insulation
2 XLPE
3
3 Inner Sheath
Halogen-free thermoplastic filler
or polyester tape
4
4 Screen
Copper wire braiding with 100 % coverage
copper tape and drain wire
5 5 Outer Sheath
Grey or black colored, halogen-free, low
smoke, flame-retardant, polyolefine based
thermoplastic compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for power and lighting applications.
Halogen-free, flame retardant and low smoke density type cables.
6
U-HFA m EMC
0,6/1 kV Screened Power & Lighting Cables
7
U-HFA m EMC
0,6/1 kV Screened Power & Lighting Cables
8
U-HFA m EMC
0,6/1 kV Screened Power & Lighting Cables
9
U-HFFR m
Construction
1 Conductor
Electrolytic, stranded, annealed, bare
1 or tinned copper, Class 2 or Class 5
2
2 Mica Glass tape
3
3 Insulation
XLPE
4 Inner Sheath
4
Halogen-free thermoplastic filler
or polyester tape
5 5 Outer Sheath
Grey or black colored, halogen-free, low smoke,
flame-retardant, polyolefine based thermoplastic
compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for power and lighting applications.
Halogen-free, flame retardant and low smoke density type cables, these cables
have function endurance according to IEC 60331.
Standards of Design & Tests : IEC 60092-353 & IEC 60092-350 & IEC 60331-21
10
U-HFFR m
0,6/1 kV Fire Resistant Unscreened Power & Lighting Cables
11
U-HFFR m
12
U-HFFR m
13
U-HFFRA m
Construction
1 Conductor
1
Electrolytic, stranded, annealed, bare
2 or tinned copper, Class 2 or Class 5
3 2 Mica Glass tape
3 Insulation
4
XLPE
5 4 Inner Sheath
Halogen-free thermoplastic filler
or polyester tape
6
5 Screen
Copper wire braiding and drain wire
6 Outer Sheath
Grey or black colored, halogen-free, low
smoke, flame-retardant, polyolefine based
thermoplastic compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for power and lighting applications.
Halogen-free, flame retardant and low smoke density type cables, these cables
have function endurance according to IEC 60331.
Standards of Design & Tests : IEC 60092-353 & IEC 60092-350 & IEC 60331-21
14
U-HFFRA m
0,6/1 kV Fire Resistant Screened Power & Lighting Cables
15
U-HFFRA m
0,6/1 kV Fire Resistant Screened Power & Lighting Cables
16
U-HFFRA m
0,6/1 kV Fire Resistant Screened Power & Lighting Cables
17
U-HFAT m
Construction
1 Conductor
1 Electrolytic, stranded, annealed, bare
or tinned copper, Class 2 or Class 5
2 Insulation
2 XLPE
3 Inner Sheath
3 Halogen-free thermoplastic filler
4 or polyester tape
4 Screen
Copper wire braiding and drain wire
5
5 Outer Sheath
Grey or black colored, halogen-free, low smoke,
flame-retardant, polyolefine based thermoplastic
compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecomunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables.
18
U-HFAT m
19
U-HFAT m
20
U-HFAT m
21
U-HFFRAT m
Construction
1 Conductor
1
Electrolytic, stranded, annealed, bare
2 or tinned copper, Class 2 or Class 5
3 2 Mica Glass tape
4
3 Insulation
XLPE
5
4 Inner Sheath
Polyester tape or filler
6 5 Screen
Copper wire braiding with drain wire
6 Outer Sheath
Green colored, halogen-free, low smoke,
flame-retardant, polyolefine based
thermoplastic compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecommunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables, these cables
have function endurance according to IEC 60331. Screened against
electromagnetic interferences.
Standards of Design & Tests : IEC 60092-376 & IEC 60092-350 / IEC 60331-21
22
U-HFFRAT m
250 V Fire Resistant Screened Telecommunication & Control Cables
23
U-HFA m
Construction
1 Conductor
1
Electrolytic, stranded, annealed, bare or tinned
copper, Class 2 or Class 5
2 Insulation
2
XLPE
3 Inner Sheath
Halogen-free thermoplastic filler or polyester tape
3
4 Screen
Copper wire braiding and drain wire
4
5 Outer Sheath
Grey or black colored, halogen-free, low smoke,
5 flame-retardant, polyolefine based thermoplastic
compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for power and lighting applications.
Halogen-free, flame retardant and low smoke density type cables.
24
U-HFA m
0,6/1 kV Screened Power & Lighting Cables
25
U-HFA m
0,6/1 kV Screened Power & Lighting Cables
26
U-HFA m
0,6/1 kV Screened Power & Lighting Cables
27
U-HFAT m (C)
Construction
1 Conductor
1
Electrolytic, stranded, annealed, bare or
tinned copper, Class 2 or Class 5
2
2 Insulation
XLPE
3 3 Collective Screen
4
Aluminium Polyester tape with tinned copper drain wire
5
4 Inner Sheath
Halogen-free thermoplastic filler or polyester tape
6
5 Screen
Copper wire braiding and drain wire
6 Outer Sheath
Grey or black colored, halogen-free, low smoke,
flame-retardant, polyolefine based thermoplastic
compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecomunication and signal
applications. Halogen-free, flame retardant and low smoke density
type cables.
28
U-HFAT m (C)
250 V Collectively Screened Telecommunication & Control Cables
29
U-HFAT m (I)
Construction
1 Conductor
1
Electrolytic, stranded, annealed, bare or tinned
copper, Class 2 or Class 5
2
2 Insulation
XLPE
3
3 Individual Screen
4 Aluminium Polyester tape with tinned
copper drain wire
5 4 Inner Sheath
Halogen-free thermoplastic filler or polyester tape
6
5 Screen
Copper wire braiding and drain wire
6 Outer Sheath
Grey or black colored, halogen free, low smoke,
flame-retardant, polyolefine based thermoplastic
compound
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
30
U-HFAT m (I)
250 V Individually Screened Telecommunication & Control Cables
31
U-HFAT m (I+C)
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecomunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables.
32
250 V Individually and Collectively Screened U-HFAT m (I+C)
Telecommunication & Control Cables
33
U-HFFRAT m (C)
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecommunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables, these cables
have function endurance according to IEC 60331. Screened against
electromagnetic interferences.
Standards of Design & Tests : IEC 60092-376 & IEC 60092-350 / IEC 60331-21
34
U-HFFRAT m (C)
250 V Fire Resistant Collectively Screened Telecommunication & Control Cables
35
U-HFFRAT m (I)
KAIJI
ON K
NIPP
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecommunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables, these cables
have function endurance according to IEC 60331. Screened against
electromagnetic interferences.
Standards of Design & Tests : IEC 60092-376 & IEC 60092-350 / IEC 60331-21
36
U-HFFRAT m (I)
250 V Fire Resistant Individually Screened Telecommunication & Control Cables
37
U-HFFRAT m (I+C)
YOK
AI
Fo u n
99
18
d
de
Cla ssNK
Technical Features
Application : Used in ships and sea vehicles for telecommunication and signal applications.
Halogen-free, flame retardant and low smoke density type cables, These
cables have function endurance according to IEC 60331. Screened against
electromagnetic interferences.
Standards of Design & Tests : IEC 60092-376 & IEC 60092-350 / IEC 60331-21
38
U-HFFRAT m (I+C)
250 V Individually and Collectively Screened Telecommunication & Control Cables
39
40