Sunteți pe pagina 1din 9

SUMMARY SHEAR CAPACITY SHEET

BRIDGE RESOLUTION
SPAN 30 m
Girder Depth 1.525 m f'c girder 60
Composite D= 1.705 m
Slab t = 0.18 m f'c deck 40

Composite Section Precast Girder Section


A 1.200 m^2 A 1.000 m^2
I 1.400 m^4 I 1.200 m^4 0.52
Y slab top 0.905 m Y girder top 0.775 m top 0.8
Y girder 0.725 m top girder Y girder bot 0.750 m bot
Y girder 0.800 m bot
diff in composite N/A & girder N/A 0.050 m

Stirrup Yield fy 500 Mpa


Girder Depth 1525 mm
No of strands
Layer yt (mm) Girder end debond 1 debond 2
strand Profile Top flange 65 4 4 4
Layer 6 1210 0 0 0
Layer 5 1260 0 0 0
Layer 4 1310 6 8 10
Layer 3 1360 6 8 10
Layer 2 1410 6 8 10
Layer 1 1460 6 8 10
28 36 44

Distance 0 1.5 3.0 4.5


web width at location 0.8 0.2 0.2 0.2
Vertical Prestress component (Vp kN) 200 200
ULS Shear Demand (V* kN) 500 500
M* kNm 5000 5000
unfactored total dead load shear Vd kN 200 200
unfactored total dead load moment Md kNm 4000 4000

Stirrup dia (mm) 12 12 12 12


no of legs 2 2 2 2
spacing (mm) 100 100 100 100
Dist 0 1.5 3 4.5
Vc 300
Vs 1266
fVn 1174
V* 0 500 0 500
NO GOOD OK NO GOOD NO GOOD

required longitudinal reinforcement force (kN) 4564


Mpa

Mpa

Pult
%fpu 250
%fpu

rands
midspan
4
0
0
12
12
12
12
52

6.0 7.5 9.0 10.5 12.0 13.5 15.0


0.2 0.2 0.2 0.2 0.2 0.2 0.2

12 12 12 12 12 12 12
2 2 2 2 2 2 2
100 100 100 100 100 100 100
6 7.5 9 10.5 12 13.5 15

0 0 0 0 0 0 0
NO GOOD NO GOOD NO GOOD NO GOOD NO GOOD NO GOOD NO GOOD
Simplified Shear Capacity for Prestressed Beams
in accordance with AASHTO LRFD Bridge Specifications 2012
BRIDGE : RESOLUTION AASHTO
Inputs Metric units imperial units Clause or
Overall height of section h 1705 mm 67.1 inches (equation)
Web width bv bv 200 mm 7.9 inches
effective shear depth (0.72h or 0.9d) dv 1228 mm 48.3 inches
concrete strength f'c 60 Mpa 8.70 ksi
Vertical Prestress component Vp 200 kN 45 kip
ULS Shear Demand V* 500 kN
M* 5000 kNm
unfactored total dead load shear Vd 200 kN
unfactored total dead load moment Md 4000 kNm

Check Shear Stress Limit (NZ 3101)


V*/0.75/(bv.dv) = 2.72 Mpa
limit = 0.2f'c or 8
Concrete Shear Capacity

Vc is the lessor of Vci or Vcw 5.8.3.4.3

Vci = 0.02(f'c)0.5.bv.dv+Vd+ViMcre/Mmax >= 0.06(f'c)0.5.bv.dv (imperial units) (5.8.3.4.3-1)


Vci = 0.0525(f'c)0.5.bv.dv+Vd+ViMcre/Mmax >= 0.158(f'c)0.5.bv.dv (SI units)

Mcre = Sc (fr+fpce - Mdnc/Snc) (5.4.3.4.3-2)


Sc is section modulus for composite section for tension fibre
caused by externally applied loads Sc = 1.75 m3
Snc = section modulus of non composite section for tension
fibre caused by externally applied loads
Snc= 1.60 m3
fcpe = compressive stress in concrete due to effective prestress
at extreme fibre of section where tensile stress is caused by
external loads
fcpec= 4.60 Mpa
fr = modulus of rupture of concrete =0.24f'c0.5 (imperical units) 0.71 ksi
=0.62f'c0.5 (SI units) fr= 4.88 MPa
Mdnc = total unfactored dead load acting on monolithic or
noncomposite section Mdnc = 1000 kNm
Mcre = 15497 kNm
Vi = factored shear force (excluding dead loads ie V*-Vd) at
section due to externally applied loads occuring simultaneously
with Mmax Vi= (V*-
Vd) = 300 kN
Mmax = maximum factored moment at section due to
externally applied loads Mmax=(M*-Md)
= Mmax= 1000 kNm
Vd = unfactored shear force at section due to unfactored dead
load Vd= 200 kN
Vci = 300 kN (5.8.3.4.3-1)
check limiting value = 67 kip or is = 300 kN at limit level

file:///conversion/tmp/scratch/394621404.xlsx page 3 of 9 08/15/2018


394621404.xlsx
Vcw = (0.06(f'c)0.5 + 0.3fpc)bv.dv + Vp (imperial units) (5.8.3.4.3-3)

fpc = compressive stress in concrete at composite cross section


centroid or junction of web and flange, due to both prestress
and moments resisted by precast member acting alone fcp= 3.74 Mpa
Vcw 775 kN
(imperial units) Vcw 174 kip

Vc= min of Vci & Vcw Vc 300 kN

Stirrup Contribution
determine angle, where Vci <Vcw, cotq=1
where Vci>Vcw : cotq= 1.0+3(fpc/f'c0.5) <=1.8 cotq = 1 (5.8.3.4.3-4)
Vs = Av.fy.dv.(cotq)/s (assuming stirrups are 90 degrees) (5.8.3.3-4)
Yield strength of stirrups Fy 500 Mpa
Area of stirrup legs Av 226 mm2
stirrup group spacing s 100 mm
Vs 1388 kN

Vn = Vc + Vs Vn 1688 kN (5.8.3.3-1)
(strength reduction factor =) f 0.75
fVn = 1266 kN
V* = 500 kN OK
provide 226.1947 mm2 at 100 mm c/c

Longitudinal Reinforcement
Aps .fps + As .fy >= M*/(dv.f)+(0.5N*/f+(V*/f-Vp)-0.5Vs)cotq) (5.8.3.5-1)
M* 5000 kNm
N* kN
V* 500 kN
required longitudinal reinforcement Aps .fps + As .fy >= 4564 kN

Note ; The area of longitudinal reinforcing need not exceed the area required to resist the
maximum moment acting alone. Longitudinal reinforcement requirementscan be satisfied
by extending the flexural reinforcement for a minimum distance of dv.cotq beyond
requirement for M*

file:///conversion/tmp/scratch/394621404.xlsx page 4 of 9 08/15/2018


394621404.xlsx
Serviceability Girder Stresses: General Case
Girder Depth 1.53 m f'c girder

U Girder Composite D= 1.71 m No of strands


Span = 0.00 Slab t = 0.18 m f'c deck

Composite Section Precast Girder Section


A 1.20 m^2 A 1.00 m^2
I 1.40 m^4 I 1.20 m^4
Y slab top 0.905 m Y girder to 0.775 m top
Y girder 0.725 m top girder Y girder bo 0.75 m bot
Y girder 0.80 m bot
diff in composite N/A & girder N/A 0.050 m

Girder Depth 1525 mm Strand location


Layer yt (mm) No of strands
strand Profile Top flange 65 4
Layer 6 1210 0
Layer 5 1260 0
Layer 4 1310 6
Layer 3 1360 6
Layer 2 1410 6
Layer 1 1460 6
28
ave yt 1196 mm

MIDSPAN STRESS

Critical Stress Stress Stress


Class Combination Moment Girder Girder Slab
Bottom Top Soffit

KNm MPa MPa MPa

P/A 3.64 3.64

P*ecc*Y/I 0.96 -0.99

Case A SUB TOTAL 4.60 2.65


Dead load unfactored applied to girder section only

file:///conversion/tmp/scratch/394621404.xlsx page 5 of 9 08/15/2018


394621404.xlsx
Case B Md 4000 -2.50 2.58

Case A+B Total 2.10 5.23

file:///conversion/tmp/scratch/394621404.xlsx page 6 of 9 08/15/2018


394621404.xlsx
60.00 Mpa
No of strands 28 yt

40.00 Mpa
Pult
P 3640 KN 0.52 %fpu 250
Ptransfer 5600 KN 0.8 %fpu
ecc mid -0.421 m
yt = 1.196 m

Strand location Girder end Girder enddebond 1


ytxN 1 0
260
0
0
7860
8160
8460
8760
33500

Stress Stress at
Slab composite
Top N/A

MPa MPa

3.64

-0.06

3.58

file:///conversion/tmp/scratch/394621404.xlsx page 7 of 9 08/15/2018


394621404.xlsx
0.17

3.74

file:///conversion/tmp/scratch/394621404.xlsx page 8 of 9 08/15/2018


394621404.xlsx
debond 2 midspan
0 0

file:///conversion/tmp/scratch/394621404.xlsx page 9 of 9 08/15/2018


394621404.xlsx

S-ar putea să vă placă și