FLEXIBLE SAMPLE HANDLING
Peak Seek Sample Temperature Control USER BENEFITS
The measurement of an Temperature control by water Easy Use
absorption band should always be circulation is possible with the
carried out at the wavelength of Series 1000 for a single cell, SIP
Low Cost
peak absorption to obtain results flowcell, or for 4 cells mounted on
of the highest accuracy and the cell changer. A special sample
Self Test and Calibration
reproducibility. compartment lid and pip port are
provided for use with water
An automatic peak seek facility is temperature control. Auto Lamp and Filter
provided. To enhance dis- Selection
crimination and accuracy
automatic compensation of the Convenient Sampling Simple Kinetics
reference energy background -
The large and accessible sample
baseline flattening - is carried out, UV Lamp Save
compartment accommodates a
followed by precise peak location.
wide range of sample holders in
The instrument is set to the peak
addition to the standard single cell UV Lamp Hours Indicator
wavelength, ready for use.
holder. These include a 4 cell
changer, water thermostatted cell 1500 Hours UV Lamp
holders and a SIP sampling system Guarantee
which fits within the sample
compartment.
3
ORDERING ACCESSORIES
SAMPLE HOLDERS Part No. SAMPLE STIRRING Part No.
Single cell holder 1010 31 00 Electronic controller for sample stirring 2010 31 00
Universal cell holder, 10mm cells upwards 1010 38 00 Cell holder for sample stirring 2021 32 00
Long pathlength cylindrical cell holder 1010 39 00 Water thermostatted holder for stirring 2010 33 00
Holder for solid samples or films 2020 33 00 LAMPS
Ultra-microcell holder : 50µl or less 2020 39 00 Deuterium lamp with hours indicator 2202 01 42
CELL CHANGERS AND HOLDERS Tungsten halide lamp - in pairs 2303 01 40
4 cell manual changer (no holder) 1010 34 00 CABLES AND COMPUTERS
4 x 10mm cell holder for manual charger 1010 24 00 RS232c cable for PC with 25 pin outlet and
Up to 4 x 50mm holder for manual charger 1010 36 00 protocol manual 2021 26 00
4 microcell manual changer and holder 2020 38 00 RS232c cable for PC with 9 pin outlet and
SIP SAMPLING protocol manual 2021 83 00
Holder for 10mm SIP cell 1010 32 00 CALIBRATION FILTERS
Holder for SIP cell up to 50mm 2020 37 00 Holmium filter in holder 202 01 44
THERMOSTATTING Didymium filter in holder 303 01 30
Water flow holder for manual 4 cell changer 1010 36 15 Set of 4 certified absorbance filters in holders 594 44 00
Water flow holder for single, SIP cell 1010 33 00 Set of 6 certified absorbance filters in holders 594 66 00
Cell compartment lid and water pipe port 1010 05 00 Set of 2 certified wavelength filters in holders 303 40 00
Specification ORDERING
Optical System Littrow monochromator using 1200L/mm
Spectrophotometers are supplied
holographic grating; coated optics
complete with single cell holder,
Optical Bandwith 8nm
power cable, operators manual and
Wavelength Selection Keyboard controlled by up-down keys short form instructions.
Wavelength Range 200-1100nm CE1021
325-1100nm CE1011
Wavelength Accuracy Within 1nm VISIBLE RANGE
Wavelength Precision 0.1nm
Wavelength Display Large seven segment bright LED’s CE 1011
Photometric Ranges -0.3 to 3.0A, 0-200%T, 0-9999C 325-1100nm Wavelength range
8nm Bandpass
Photometric Accuracy 1% or 0.005A whichever is greater
Photometric Noise Less than + 0.001A/Hr.
Straylight Less than 0.05% at 220nm and 340nm CE1021
Absorbance Zero Stability Better than + 0.001A/Hr. UV/VISIBLE RANGE
Absorbance Zero Setting 0A and 100%T automatic by press button
CE 1021 Spectrophotometer
Peak Seek Automatic with baseline flattening
200-1100nm Wavelength range
Filter and Lamp Selection Automatic - coupled to wavelength 8nm Bandpass
Self Test and Calibration Automatic at switch on
Computer Interface Bi-directional serial RS232c Option F
Sample Compartment Dimensions 196 x 105 x 107mm (l x d x h) Sip Sampling : Factory fitted only
Size 480 x 340 x 200mm (l x d x h)
System 1
Power Requirement 110-250V, 50/60Hz, 120W CE1010, 170W CE1021 Spectrophotometer (with option), 2
Weight 10kg CE1011; 17kg CE1021 cells, spare lamp(s), spare fuses
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND
TELEPHONE: 01223 420821 FAX: 01223 420475 ISO 9001 : 2000
CERTIFIED COMPANY
E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com
4
UV-VISIBLE SPECTROPHOTOMETERS
The Choice
Aurius Series Super Aurius Series
With an optical bandwidth of 4nm and superb stability, The Super Aurius instruments are unique for their
accuracy and precision these very easy to use very high performance scanning, with derivatives,
instruments are ideal general purpose overlay, extended analytical power and multi-cell
spectrophotometers. Kinetics. They cover the full 190-1100nm wavelength
Excellent for routine and quality control laboratories, range with a narrow 1.8nm optical bandwidth.
they offer a wide range of techniques with wavelength With straylight of 0.01%, wavelength precision of
scanning as an option. Both UV and Visible versions 0.1nm and baseline stability better than ±0.001A/hr,
are available with full validation procedures. the most demanding analysis may be undertaken.
Accurate Quantification
For optimum accuracy when measuring concentration, a calibration
line may be fitted to a series of up to 30 standards or replicates.
Accuracy is improved over using a single known concentration.
Editing of Data
Suspect standards revealed by the initial fit
may be deleted or replaced for a new fit. Up
to 30 curves may be stored security
protected.
Wavelength Scanning
Wavelength scanning from 190-1100nm is standard
on Super Aurius instruments with a narrow 1.8nm
optical bandwidth. For the Aurius range scanning
software is optional with a 4nm optical bandwidth.
3
FAST : EASY TO USE :
SCANNING QUANTITATION
NOTE: This column applies only to Super Aurius.
Scan is an option on the Aurius range.
4
POWERFUL SOFTWARE
5
FAST PROGRAM ANY ASSAY
Assay Program
Complex assays only require text entry of
any formula with up to 76 characters. For
complex calculations up to 20 such formulae
may be entered and linked for formidable
computing power without a PC.
6
FOR MORE POWER - PERFORMANCE
Super Aurius Performance
The Super Aurius range offers uncompromising
performance and analytical power only available in
much larger and more expensive instruments. With
1.8nm optical bandwidth even closely spaced or narrow
bands may be resolved, as illustrated by the benzene
vapour spectrum shown here.
With the added power of the ‘Quant S’ software
module, scans may be overlayed and differencing,
stripping and band area computation carried out.
Storage for 100 spectra, with full security, is provided.
Derivative spectra are also standard, with multi-cell
Kinetics provided by the ‘Kinetics M’ module.
Derivative Spectra
Band Quantification
Multi-Cell Kinetics
The Super Aurius Series offers multi-cell Kinetics as
well as single cell Kinetics as available on the Aurius
Series. Plots are displayed on the screen and printed.
DataStream
Cecil DataStream provides rapid transfer of
raw data, or data processed and formatted
by the spectrophotometer, to a PC for
instant display. Scans, measurements,
programmed measurements and
sophisticated analytical procedures may all
be transferred with great ease.
Transferred data may be saved on disk or
incorporated into a spread sheet or maths
pack. Incorporation into Microsoft Excel is
shown here for display, manipulation,
graphical presentation, archiving or report
generation. Full PC control of the
instrument is provided.
Simplicity of operation is a key feature as
any familiar spreadsheet or maths package
- Excel, Lotus 123, Grafit etc - may be used,
avoiding a learning cycle and saving
valuable time. Reports are printed using
any printer supported by Windows.
Advanced Kinetics
For more advanced reaction kinetics data
manipulation, raw kinetics data generated
by the spectrophotometer may be captured
and transferred by DataStream into Grafit
Software.
Using a suitable template the Lineweaver
Burk transformation, shown here, was
automatically plotted and the values of Km
and Vmax extracted. Other transformations
such as Eadie-Hofstee etc. may be used.
Linear, non linear, or polynomial curve
fitting are easily performed together with
linear regression analysis.
Dissolution Assay
8
PERFORMANCE VALIDATION : GLP
Absorbance Validation
The Pharmacopoeia (EP/BP) test for absorbance
accuracy is one of the tests provided. The test
measures the values of peaks and valleys in the
absorbance spectrum of a 60mg/L solution of
Potassium Dichromate in a 10mm pathlength cuvette.
The results of such a test run are shown here.
Straylight
9
UNIVERSAL ACCESSORY RANGE
10
ORDERING
Spectrophotometers are supplied complete with cell AURIUS
holder, power cable, instruction manual and short
form operating instructions. VISIBLE RANGE
CE 2011 Spectrophotometer
SUPER AURIUS 325-1100nm Wavelength range; 4nm Bandpass
CE 2031 Spectrophotometer
CE 3021 Spectrophotometer
325-1100nm Wavelength range; 4nm Bandpass.
1.8nm Bandpass, 190-1100nm wavelength range,
With integral printer
scanning.
CE 3041 Spectrophotometer
1.8nm Bandpass, 190-1100nm wavelength range, UV/VISIBLE RANGE
scanning. With integral printer. CE 2021 Spectrophotometer
190-1100nm Wavelength range, 4nm Bandpass
CE 3021D and CE 3041D Tablet Dissolution
Spectrophotometers CE 2041 Spectrophotometer
Special versions suitable for tablet dissolution 190-1100nm Wavelength range, 4nm Bandpass.
applications, using TD software. With integral printer
CE 2021D and CE 2041D Tablet Dissolution
System 1 : Cells and Spares Spectrophotometers
Spectrophotometer with two silica cells, spare lamps, Special version suitable for tablet dissolution
spare fuses and dust cover. applications, using TD software
Example: CE2021 system 1 is a CE 2021 with spare System 1
deuterium and tungsten lamps, spare fuses, 2 silica Spectrophotometer, spare lamp(s) spare fuses,
cells and dust cover. 2 cells and dust cover.
ORDERING ACCESSORIES
11
SPECIFICATIONS HIGHLIGHTS
Monochromator Littrow, 1200 lines/mm holographic grating
Optical Bandwidth 4nm - Aurius; 1.8nm Super Aurius BENEFITS
Wavelength Range 190-1100nm; 325-1100nm visible versions
Wavelength Accuracy Better than ±1nm High Performance Scans
Wavelength Reproducibility 0.1nm
Self Test and Calibration Automatic at switch on
Straylight Typically less than 0.01% at 220 and 340nm
Derivative Spectra
Display Screen - LCD High resolution backlit with contrast control
Display Scrolling Provides 6 screen widths for viewing plots etc. Time Plots
Autozero Automatic by press button
Photometric Ranges Digital display of -0.3-3A, 0-200%T, 0-9999C Assay Formula Program
Photometric Accuracy ±0.005A or 1% whichever is greater
Photometric Noise Less than ±0.00004A (500nm RMS)
Stability Better than 0.001A/hour at constant temp. DataStream - Fast Data to PC
Multi-Wavelength Analysis 2 and 3 wavelength methods
Assay Program Enter multi-wavelength formula for automatic Display Scrolling - 6 Screens Wide
computation and formatting of any assay
Curve Fitting and Editing Linear, quadratic or cubic; up to 30 standards
Cell and Wavelength Programming Up to 8 cells and 10 wavelengths combined E-SEF Software Call-up
Method Storage Up to 30 methods stored in protected memory
Absorbance Ratioing 260/280nm or any two selected wavelengths Integral Printer Versions
Peak Seek Automatic search, baseline corrected
Reaction Kinetics Tabulated results, reaction plots, reprocessing
Method Storage
Batch Sampling 100 samples, internal control, screen display
Real Time Clock Timed and dated reports
Computer/printer interfaces Bi-directional serial RS232 and parallel ports Cell and Wavelength Programs
Sample Temperature Displayed and set from keyboard
Size 480 x 340 x 205mm Kinetics, Single/Multi-cell
Weight 16.8kg Visible; 18.6kg UV; + 0.9kg with printer
Power Requirements 110-250V, 50/60Hz; 120W/170W UV versions
Multi-Wavelength Assays
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice. Full Validation Procedures
DNA / RNA
ANALYSER
™
DEDICATED
TED TO DNA / RNA
Simplicity of Operation
Insert the reference, press ZERO, then insert the
sample and press RUN to obtain a fully documented
report complete with header, sample number and
space for the operators name etc. Operation could not
be more simple.
Operators may create and store up to 30 of their own
methods with the method storage option.
STANDARD SOFTWARE
● A260/A280 Ratio ● ss DNA concentration
● A260/A280 with background correction at 320nm ● ds DNA concentration
● A260/A230 Ratio ● RNA concentration
● A260/A230 with background correction at 320nm ● Direct UV method for protein at 280nm
SAMPLE CELL SELECTION Volume Pathlength Cell Description Cell Type Part Number
(µL) (mm)
2000 10 Standard A 202 07 26
A range of UV transmitting silica cells is
500 10 Semi-micro, thick base B 202 07 57
available. The listing given here enables the
250 10 Micro, thick base C 202 07 38
cell appropriate to the sample volume to be
70 10 Ultra micro D 202 07 15
chosen. All cells except the standard must be
50 10 Ultra micro E 2020 07 01
of the self masking type.
use holder 2020 39 00
10 10 Ultra micro, pipette filling F 202 07 64
Using a 10mm pathlength cell an absorbance A
1000 5 Standard - use spacer 202 07 25
value of 1 is estimated for a concentration of F
5 5 Ultra micro, pipette filling 202 07 63
50µL/mL of ds DNA
A B C D E F
2
AND MOLECULAR BIOLOGY
Printout of Assays
The printouts shown here are for typical
assays using the Bradford method at 595nm,
the determination of ds DNA, and the results
of the Kalb Bernlohr determination of nucleic
acids and proteins.
3
SPECIFICATION
™
ORDERING
SM4 Bacterial Growth
Optical density at 600nm Plot of curve fitted to standards
ORDERING
ACCESSORIES AND SPARES
Cell holder for 50µL cells - type E 2020 39 00
Printer connection cable 8000 71 00
BENEFITS
SPECIFICATION
Dot matrix printer 8000 70 01
Spare deuterium lamp 2202 01 42
2 Certified wavelength filters with certificate 303 40 00
ACCESSORIES
OPTIONAL AND SPARES
SOFTWARE - E-SEF Enabled
4 Certified Absorbance filters with certificate 594 99 00
Dust cover 2020 01 23
SPECIFICATION ORDERING
Wavelength Range 190-370nm, 595 and 600nm
Wavelength Accuracy ±1nm
OPTIONAL SOFTWARE - E-SEF Enabled
Wavelength Reproducibility ±0.1nm
Each GeneQuest analyser is
BENEFITS
supplied complete with an ultra
Wavelength Calibration Automatic at switch on
microcell holder, power cable,
Wavelength Selection Automatic for assay selected
operator’s manual and short
Monochromator
Optical Bandwidth
Littrow 1200 lines per mm holographic grating
4nm
ACCESSORIES AND S
form operating instructions.
Straylight Less than 0.02% at 280nm (Acetone)
Photometric Range -0.3 - 3 Absorbance CE 2301 Analyser
Photometric Linearity ±1% or ±0.005, whichever is greater SPECIFICATION
190-370nm, 595 and 600nm
4nm optical bandwidth
Stability Better than 0.001A/hour at 240nm constant T.
Real Time Clock Timed and dated reports
Light Source Deuterium lamp with life indicator CE 2302 Analyser
Printer Output Centronics parallel port OPTIONAL
190-370nm, 595 and SOFTWARE
600nm
Power Requirements 110-240V, 50/60Hz, 100W 4nm optical bandwidth
Size and Weight 480 x 340 x 205, 17.6Kg, (18.5kg printer version) With integral printer
GeneQuest™ is a registered Trade Mark of Cecil Instruments Ltd.
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB4 6AZ ENGLAND
ISO 9000
TELEPHONE: 01223 420821 FAX: 01223 420475
CERTIFIED COMPANY
E-MAIL: info@cecil-instruments.co.uk WEB SITE: www.cecil-instruments.co.uk
4
TM TM
ANALYSIS
BIO ANAL YSIS
BioQuest TM
Compact design, 4nm optical bandwidth. Fully programmed for
bioanalysis, scanning, integral printer version.
BioAquariusTM
Symmetrical double beam design, 1.8nm optical bandwidth. Fully
programmed for bioanalysis. A very capable general purpose scanning
double beam spectrophotometer.
Lowry (high sens.) Direct UV A special holder accommodates cells of 50µL for
measuring valuable small samples. These cells may be
Assays may also be carried out using the Warburg and used in both sample and reference beams in the
Christian 2 or 3 wavelength methods and the Kalb and BioAquarius instrument.
Bernlohr procedures, all of which are preprogrammed.
For the ultimate in small sampling a nano cell or special pipette
loaded 5µL cell with 5mm pathlength are available.
Nucleic Acid Assays
Concentration and purity may be determined by the Experimental Thermal Melt (Tm)
methods of Warburg and Christian, Kalb and Bernlohr
Thermoelectric temperature programming is available
or using user selected parameters.
for thermal melt (Tm) determinations.
DNA, ssDNA, dsDNA, RNA and oligonucleotides may A fully annotated plot of Absorbance against
be quantified and examined for purity using one temperature is displayed. Data may be reprocessed,
wavelength, or two or three wavelength ratio methods. derivatised, overlayed, stored or transferred to a PC.
Molecular concentration may be determined for Oligo Method Generation and Storage
Samples and theoretical melting points for DNA All preprogrammed methods may be modified by the
samples calculated using the nearest neighbour user to meet their requirements. Any modified method
interaction model. may then be stored as an additional method in code
protected memory.
Concentration Curve Fitting
For more accurate measurements and for DataStream - Data to PC
measurements where Beer’s law is not obeyed a The DataStream system allows all data to be exported
straight line quadratic or cubic curve may be fitted to rapidly and with great ease, to a PC for incorporation
up to 30 standards or replicate standards. Editing of into a spreadsheet or mathematical package of the
suspect standards may be carried out and the final users choice - Excel, Grafit etc - for report generation
curve stored in code protected memory for future use. and mathematical manipulation.
2
MOLECULAR BIOLOGY
Program Any Assay Application Example
The Cecil Assay program software module enables users to A typical experiment is illustrated here.
mathematically formulate any assay for measurement at up to 10 The scans of protein, DNA and a sample
wavelengths. Rapid text entry of any formula and setting a mixture are shown overlayed over the
wavelength program is all that is required for automatic range 230-330nm.
measurement of any sample. A cell program may be incorporated for
multiple automatic sample measurements. Up to 20 formulae, each An automatic calculation of the ratios
with up to 76 characters, may be combined for the most complex of and the DNA purity of the sample was
assays. made using the pre-programmed three
Never before has programming assays for automatic measurement wavelength ratio method. The results
and computation been so easy. were automatically tabulated as shown.
ORDERING ACCESSORIES
BioQuestTM BioAquariusTM BioQuestTM BioAquariusTM
Cell Holders Temperature Control - Water
Micro sipette 10mm cell holder 1010 32 00 503 26 00 Single or Sipette cell holder 1010 33 00 503 36 00
Adjustable holder for micro cell 6600 57 00 4 cell holder 2020 36 15 202 36 16
50µl ultra microcell holder 2020 39 00 8020 39 00 2 x 4 cell holder, sample and ref. 202 36 15
Rectangular cells up to 100mm 1010 38 00 595 27 00 6 cell holder 5500 36 15
Cylindrical cells up to 100mm 1010 39 00 595 26 00 Thermoelectric Control
Cell Changers Thermoelectric Controller CE 2024 CE 2024
4 cell auto changer, no holder 2021 34 00 9070 31 00 Single or sipette cell holder 2021 31 20 8020 56 00
Holder for 4 x 10mm cells 2010 24 00 2010 24 00 4 cell holder 2021 32 20 9070 57 00
6 cell auto changer, no holder 9070 34 00 2 x 4 cell holder 9070 58 00
6 cell auto changer and holder 2021 36 00 6 cell holder 9070 59 00
Holder for 6 x 10mm cells 5500 33 00 Gel Scanning
8 cell auto changer with holder 3021 37 00 9070 32 00 Gel scanner - no trough 9070 39 00
4 position microcell changer 2020 38 00 505 38 00 Gel trough - 5 x 100mm, silica 570 07 02
Sipette and Batch Sampling Printers and Cables
Sipette system, no holder or cell 2021 21 00 9070 21 00 RS232 cable for 25 pin PC 2021 26 00 2021 26 00
10mm sipette cell 202 07 02 202 07 02 RS232 cable for 9 pin PC 2021 83 00 2021 83 00
40 Batch sampler with pump 2021 82 00 2021 82 00 Printer connection cable 8000 71 00 8000 71 00
100 Batch sampler with pump 2021 82 02 2021 82 02 Dot matrix printer 8000 70 01 8000 70 01
Lamps Colour ink jet printer 8000 72 01 8000 72 01
Deuterium lamp with indicator 2202 01 42 2202 01 42 Certified Calibration Filter Sets
Tungsten halide lamp - in pairs 2303 01 40 2303 01 40 2 Wavelength filters 303 40 00 303 40 00
Sample Stirring 4 Absorbance filters 594 44 00 594 44 00
Electronic stirrer 2010 31 00 2010 31 00 6 Absorbance filters 594 66 00 594 66 00
Cell holder 10mm cell 2010 32 00 579 02 00 2 Wavelength and 6 Abs. filters 594 77 00 594 77 00
3
TM
ORDERING
Spectrophotometers are supplied
complete with cell holder, power
SPECIFICATIONS cable, operators manual and short
BioQuestTM BioAquariusTM form operating instructions.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND
ISO 9001 : 2008
TELEPHONE: 01223 420821 FAX: 01223 420475
CERTIFIED COMPANY
E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com
4
UV-VISIBLE SPECTROPHOTOMETERS
The Choice
Aurius Series Super Aurius Series
With an optical bandwidth of 4nm and superb stability, The Super Aurius instruments are unique for their
accuracy and precision these very easy to use very high performance scanning, with derivatives,
instruments are ideal general purpose overlay, extended analytical power and multi-cell
spectrophotometers. Kinetics. They cover the full 190-1100nm wavelength
Excellent for routine and quality control laboratories, range with a narrow 1.8nm optical bandwidth.
they offer a wide range of techniques with wavelength With straylight of 0.01%, wavelength precision of
scanning as an option. Both UV and Visible versions 0.1nm and baseline stability better than ±0.001A/hr,
are available with full validation procedures. the most demanding analysis may be undertaken.
Accurate Quantification
For optimum accuracy when measuring concentration, a calibration
line may be fitted to a series of up to 30 standards or replicates.
Accuracy is improved over using a single known concentration.
Editing of Data
Suspect standards revealed by the initial fit
may be deleted or replaced for a new fit. Up
to 30 curves may be stored security
protected.
Wavelength Scanning
Wavelength scanning from 190-1100nm is standard
on Super Aurius instruments with a narrow 1.8nm
optical bandwidth. For the Aurius range scanning
software is optional with a 4nm optical bandwidth.
3
FAST : EASY TO USE :
SCANNING QUANTITATION
NOTE: This column applies only to Super Aurius.
Scan is an option on the Aurius range.
4
POWERFUL SOFTWARE
5
FAST PROGRAM ANY ASSAY
Assay Program
Complex assays only require text entry of
any formula with up to 76 characters. For
complex calculations up to 20 such formulae
may be entered and linked for formidable
computing power without a PC.
6
FOR MORE POWER - PERFORMANCE
Super Aurius Performance
The Super Aurius range offers uncompromising
performance and analytical power only available in
much larger and more expensive instruments. With
1.8nm optical bandwidth even closely spaced or narrow
bands may be resolved, as illustrated by the benzene
vapour spectrum shown here.
With the added power of the ‘Quant S’ software
module, scans may be overlayed and differencing,
stripping and band area computation carried out.
Storage for 100 spectra, with full security, is provided.
Derivative spectra are also standard, with multi-cell
Kinetics provided by the ‘Kinetics M’ module.
Derivative Spectra
Band Quantification
Multi-Cell Kinetics
The Super Aurius Series offers multi-cell Kinetics as
well as single cell Kinetics as available on the Aurius
Series. Plots are displayed on the screen and printed.
DataStream
Cecil DataStream provides rapid transfer of
raw data, or data processed and formatted
by the spectrophotometer, to a PC for
instant display. Scans, measurements,
programmed measurements and
sophisticated analytical procedures may all
be transferred with great ease.
Transferred data may be saved on disk or
incorporated into a spread sheet or maths
pack. Incorporation into Microsoft Excel is
shown here for display, manipulation,
graphical presentation, archiving or report
generation. Full PC control of the
instrument is provided.
Simplicity of operation is a key feature as
any familiar spreadsheet or maths package
- Excel, Lotus 123, Grafit etc - may be used,
avoiding a learning cycle and saving
valuable time. Reports are printed using
any printer supported by Windows.
Advanced Kinetics
For more advanced reaction kinetics data
manipulation, raw kinetics data generated
by the spectrophotometer may be captured
and transferred by DataStream into Grafit
Software.
Using a suitable template the Lineweaver
Burk transformation, shown here, was
automatically plotted and the values of Km
and Vmax extracted. Other transformations
such as Eadie-Hofstee etc. may be used.
Linear, non linear, or polynomial curve
fitting are easily performed together with
linear regression analysis.
Dissolution Assay
8
PERFORMANCE VALIDATION : GLP
Absorbance Validation
The Pharmacopoeia (EP/BP) test for absorbance
accuracy is one of the tests provided. The test
measures the values of peaks and valleys in the
absorbance spectrum of a 60mg/L solution of
Potassium Dichromate in a 10mm pathlength cuvette.
The results of such a test run are shown here.
Straylight
9
UNIVERSAL ACCESSORY RANGE
10
ORDERING
Spectrophotometers are supplied complete with cell AURIUS
holder, power cable, instruction manual and short
form operating instructions. VISIBLE RANGE
CE 2011 Spectrophotometer
SUPER AURIUS 325-1100nm Wavelength range; 4nm Bandpass
CE 2031 Spectrophotometer
CE 3021 Spectrophotometer
325-1100nm Wavelength range; 4nm Bandpass.
1.8nm Bandpass, 190-1100nm wavelength range,
With integral printer
scanning.
CE 3041 Spectrophotometer
1.8nm Bandpass, 190-1100nm wavelength range, UV/VISIBLE RANGE
scanning. With integral printer. CE 2021 Spectrophotometer
190-1100nm Wavelength range, 4nm Bandpass
CE 3021D and CE 3041D Tablet Dissolution
Spectrophotometers CE 2041 Spectrophotometer
Special versions suitable for tablet dissolution 190-1100nm Wavelength range, 4nm Bandpass.
applications, using TD software. With integral printer
CE 2021D and CE 2041D Tablet Dissolution
System 1 : Cells and Spares Spectrophotometers
Spectrophotometer with two silica cells, spare lamps, Special version suitable for tablet dissolution
spare fuses and dust cover. applications, using TD software
Example: CE2021 system 1 is a CE 2021 with spare System 1
deuterium and tungsten lamps, spare fuses, 2 silica Spectrophotometer, spare lamp(s) spare fuses,
cells and dust cover. 2 cells and dust cover.
ORDERING ACCESSORIES
11
SPECIFICATIONS HIGHLIGHTS
Monochromator Littrow, 1200 lines/mm holographic grating
Optical Bandwidth 4nm - Aurius; 1.8nm Super Aurius BENEFITS
Wavelength Range 190-1100nm; 325-1100nm visible versions
Wavelength Accuracy Better than ±1nm High Performance Scans
Wavelength Reproducibility 0.1nm
Self Test and Calibration Automatic at switch on
Straylight Typically less than 0.01% at 220 and 340nm
Derivative Spectra
Display Screen - LCD High resolution backlit with contrast control
Display Scrolling Provides 6 screen widths for viewing plots etc. Time Plots
Autozero Automatic by press button
Photometric Ranges Digital display of -0.3-3A, 0-200%T, 0-9999C Assay Formula Program
Photometric Accuracy ±0.005A or 1% whichever is greater
Photometric Noise Less than ±0.00004A (500nm RMS)
Stability Better than 0.001A/hour at constant temp. DataStream - Fast Data to PC
Multi-Wavelength Analysis 2 and 3 wavelength methods
Assay Program Enter multi-wavelength formula for automatic Display Scrolling - 6 Screens Wide
computation and formatting of any assay
Curve Fitting and Editing Linear, quadratic or cubic; up to 30 standards
Cell and Wavelength Programming Up to 8 cells and 10 wavelengths combined E-SEF Software Call-up
Method Storage Up to 30 methods stored in protected memory
Absorbance Ratioing 260/280nm or any two selected wavelengths Integral Printer Versions
Peak Seek Automatic search, baseline corrected
Reaction Kinetics Tabulated results, reaction plots, reprocessing
Method Storage
Batch Sampling 100 samples, internal control, screen display
Real Time Clock Timed and dated reports
Computer/printer interfaces Bi-directional serial RS232 and parallel ports Cell and Wavelength Programs
Sample Temperature Displayed and set from keyboard
Size 480 x 340 x 205mm Kinetics, Single/Multi-cell
Weight 16.8kg Visible; 18.6kg UV; + 0.9kg with printer
Power Requirements 110-250V, 50/60Hz; 120W/170W UV versions
Multi-Wavelength Assays
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice. Full Validation Procedures
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
™
™
PROGRAMMED FOOD AND
DietQuest ™ for Food and Beverage Analysis
Cecil Instruments offer three DietQuest™ spectrophotometers
fully pre-programmed for both food and beverage analysis.
Methods include single and multi-wavelength measurements
and spectral scanning. The DietQuest™ UV and the VIS
versions are as shown on the right.
All the pre-programmed methods are defined by national and
international bodies and trade associations including the
following:
AACC, AOAC, ALVA, APA, ASBC, BS-EN, CAA, EBC, DIN, FDA,
FIL-IDF, GUdRI, ICC, IFU, IoB, IOCCC, ISO, MAFF, MEBAFA,
MEBAK, NEN, NF, OIV, OJEC.
User Programming
Never before has user programming of assays for automatic
Sipette Sampling
measurement and computation been so simple and rapid. Samples may be handled rapidly and without cell handling
using the sipette sampling system. Sample volume is user
Cecil Assay Programme software allows any assay to be selected and low cross contamination occurs even with
formulated for up to 10 wavelengths. Rapid entry of text and samples as small as 300µL.
formulae and setting a wavelength program is all that is
required.
Flexibility of Application
DietQuest™ spectrophotometers additionally have all the
functions of a high quality spectrophotometer and may
therefore find wide application in a testing laboratory. Where
only visible determinations are required the ‘DietQuest : VIS’
is offered. The high performance double beam instrument
‘DietQuest : D/B’ completes the range and is shown below.
Reaction Kinetics
Enzyme reaction methods using kits supplied by Boehringer
- Mannheim, Roche, Diogen, Megazyme etc. have been pre-
programmed for a single cell or for 4 or 6 cells in an
automatic changer.
Reaction curves are displayed on screen and regression
analysis applied to the user selected part of the curve. A
number of the assays are simple end point measurements.
Sample temperature control, where required, is available
using either water circulation or Peltier Thermoelectric cell
holders and controller.
DataStream - Data to a PC
Both raw, and processed and formatted data may be rapidly
exported to a PC for incorporation into a spreadsheet or
mathematical package of the users choice, e.g. Excel, Grafit
etc. for manipulation and report generation.
2
D BEVERAGE ANALYSIS
Pre-programmed Convenience
The versatility of the DietQuest™ spectrophotometers is illustrated by the partial list of pre-programmed tests
shown. Tests may be modified, or new tests programmed and stored by the user.
Program W Quant S
Wavelength program for up to 10 wavelengths Spectral storage, overlayed spectra, quantification of
corrected bands etc.
Scan - DietQuest : VIS only DataStream
Wavelength scan with peak labelling and time-course plots Fast data transfer to PC; PC control of instrument
Kinetics Validation
Kinetic measurements with plots and reprocessing Validation of Absorbance, wavelength, bandwidth, straylight etc .
3
™
SPECIFICATIONS
CE 3410 CE 2410 CE 7210
DietQuest : UV DietQuest : VIS DietQuest : D/B
Stability Better than 0.001A/hr Better than 0.001A/hr Better than 0.0001A/hr
Size and Weight 480 x 340 x 205; 19.5kg 480 x 340 x 205; 17.7kg 635 x 410 x 210; 33kg
ORDERING INSTRUMENTS
Instruments are supplied complete with cell holder(s), power cable, manual and brief operating instructions.
ORDERING ACCESSORIES
CE3410 / CE2410 CE7210 CE3410 / CE2410 CE7210
Cell Holders Temperature Control - Water
Micro sipette 10mm cell holder 1010 32 00 503 26 00 Single or sipette cell holder 1010 33 00 503 36 00
Adjustable holder for micro cell 6600 57 00 4 cell holder 2020 36 15 202 36 16
Rectangular cells up to 100mm 1010 38 00 595 27 00 2 x 4 cell holder, sample and ref. 202 36 15
Cylindrical cells up to 100mm 1010 39 00 595 26 00 6 cell holder 5500 36 15
Cell Changers Thermoelectric Control
4 cell auto changer, no holder 2021 34 00 9070 31 00 Thermoelectric Controller CE 2024 CE 2024
Holder for 4 x 10mm cells 2010 24 00 2010 24 00 Single or sipette cell holder 2031 31 20 8020 56 00
6 cell auto changer, no holder 9070 34 00 4 cell holder 2021 32 20 9070 57 00
6 cell auto changer and holder 2021 36 00 2 x 4 cell holder, sample & ref. 9070 58 00
Holder for 6 x 10mm cells 5500 33 00 6 cell holder 9070 59 00
4 position microcell changer 2020 38 00 505 38 00 Printers and Cables
Sipette and Batch Sampling RS232 cable for 25 pin PC 2021 26 00 2021 26 00
Sipette system, no holder or cell 2021 21 00 9070 21 00 RS232 cable for 9 pin PC 2021 83 00 2021 83 00
10mm sipette cell 202 07 02 202 07 02 Printer connection cable 8000 71 00 8000 71 00
40 batch sampler with pump 2021 82 00 2021 82 00 Dot matrix printer 8000 70 01 8000 70 01
100 batch sampler with pump 2021 82 02 2021 82 02 Colour ink jet printer 8000 72 01 8000 72 01
Lamps Print rolls and ribbon 2020 03 20
Deuterium lamp with indicator 2202 01 42 2202 01 42 Certified Calibration Filter Sets
Tungsten halide lamp - in pairs 2303 01 40 2303 01 40 2 Wavelength filters 303 40 00 303 40 00
Sample Stirring 4 Absorbance filters 594 44 00 594 44 00
Electronic stirrer 7200 31 01 7200 31 01 6 Absorbance filters 594 66 00 594 66 00
Cell holder 10mm cell 2010 32 00 579 02 00 2 Wavelength and 6 Abs. Filters 594 77 00 594 77 00
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND
ISO 9001:2008
TELEPHONE: +44 (0) 1223 420821 FAX: +44 (0) 1223 420475 CERTIFIED COMPANY
E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com
4
UV:SPECTROPHOTOMETERS
TRUE SYMMETRICAL DOUBLE BEAM
SUPERB VERSATILITY
to expand your library of methods, without delay, when a new Screen Scrolling
application arises within your laboratory.
CHOICE OF OPTICAL BANDWIDTH Scrolled Screen Width
Method Operation 430mm
SUPERB VERSATILITY
Any procedure may be stored as a method in the security code
protected integral memory of the Aquarius instruments. When a
Dynamic Scan Recall
method is recalled, all instrument parameters are automatically set, Full Reference Sample Space
without operator intervention, thus ensuring that the original
ACCURACY : FLEXIBILITY : FAST-OPERATION
conditions are exactly replicated. Method Storage
Tables of all peaks and valleys are produced together with Scan rate 1 to 4000nm/min
instrument, sample and operator details. Scans recalled from the
instruments integral memory or by dynamic scan recall are also fully Wavelength Precision 0.1nm
documented.
Straylight <0.02%
The screens shown are not two separate displays but part of a
continuous display viewed by scrolling. Validation Software
3
POWERFUL INTEGRAL SOFTWARE
Sampling SCROLLING
DISPLAY Flexibility OF SCANS
The design of the double beam optical sampling allows
almost identical space and facilities in both the sample and
CHOICE OF OPTICAL BANDWIDTH
reference beams. Multi-cell reference sampling, with
temperature control is therefore possible.
DataStream
FULL VALIDATION PROCEDURES
Data may be transferred from the spectrophotometer to a
PC, or the software used to control the instrument from a
Multi-User Convenience WIDEST ACCESSORY RANGE
PC. Datastream software, developed by Cecil Instruments,
has a wide range of facilities including graphical and
Aquarius double beam instruments were designed
tabular presentation, normalisation of overlayed traces,
for the greatest convenience in a laboratory where
point and peak pick using a cursor, library facilities, data
multi user operation is required.
storage in files on disk, history logging and copy and paste
All methods, stored scans, plots, curves and data to other applications such as Excel, Word etc.
remain in secure integral memory, tamper
protected by passwords, readily accessible to all
operators without the possibility of mislaid disks The photograph below shows an Aquarius instrument in
or plug in card modules. use in Cecil Instruments applications laboratory.
4
FULL REFERENCE BEAM SPACE
DISPLAY
DISPLAY SCROLLING OF SCANS
CHOICE
Curve and LineOF OPTICAL BANDWIDTH
Fitting
A straight line, quadratic or cubic curve may automatically be fitted to a
set of up to 30 standards. Fits may be made with an intercept or forced
SUPERB VERSATILITY
through zero. Replicate standards may be used for any given
concentration. All entries are prompted for simplicity of operation. A
quadratic curve fit is shown here.
Curve/Line Fit
Curve Storage
Editing of Standards
Absorbance Ratio
Absorbance Difference
Measurements in A, C, %T
5
DISPLAY SCROLLING OF SCANS
SUPERB VERSATILITY
Optical Bandwidth
The Aquarius range provides the choice of fixed
bandwidth of less than 2nm, 1nm, or variable
ACCURACY : FLEXIBILITY : FAST-OPE
bandwidth of 0.5, 1, 2 and 4nm. The variable
resolution performance of the CE 7500 is ideal for
samples with sharper features requiring high
FULL VALIDATION PROCEDURES
resolution - particularly vapours and some liquid
samples.
Micro-Sipette Sampling
Samples of 300µl or less, and multiple samples, may be
measured with very low cross contamination.
Ultra-Micro Sampling
Valuable samples, such as biological samples prepared
with costly reagents, may be measured using a special
ultra-microcell and holder. With the system, samples of
50µl or even less may be accurately measured.
Tablet Dissolution
The CE 7460 and CE 7560 versions of Aquarius are fitted
with a special cell compartment and pipe port for tablet
dissolution assays.
6
CHOICE OF OPTICAL BANDWIDTH
SUPERB VERSATILITY
VERSATILITY
This has been transformed into the Eadie-Hofstee format and plotted to give better precision in the calculation of
these important factors and constants.
Other transformations are available such as Lineweaver-Burk and the Hill plot for allosteric enzyme systems.
PC Data Manipulation
Band Quantification
Accurate quantitative assays using band area or height,
corrected for background absorption, are exceptionally
easy to carry out with the easy to use Aquarius
instruments.
7
SUPERB VERSATILITY
ACCURACY : FLEXIBILITY
8
:F
FAST
AST-OPERA
-OPERATION
TION
EDURES
SYSTEM FUNCTIONS SAMPLING
NGE
Integral Control System Variable or Fixed Bandwidth
All control software is within the instrument, tamper proof, Optical bandwidth selectable down to 0.5nm is provided by
providing easy menu driven operation with massive safe the CE7500 and allows the fine structure of narrow bands to
storage for scans, plots, curves etc. PC control and data be resolved which remain unresolved at just under 2nm
transfer to a PC are provided. bandwidth in instruments such as the CE7400.
9
ACCURACY : FLEXIBILITY : FAST-OP
FULL VALIDA
VALIDATION
TION PROCEDURES
Instrument Validation
Assessment of instrument performance is readily
carried out using the validation software module built
into all Aquarius instruments and released by E-SEF,
‘Encoded software enhancement facility’.
The optical bandwidth of the instrument may be The Pharmacopoeia (EP/BP) test for absorbance
validated by measuring the half height width of the accuracy, using a 60mg/L solution of Potassium
narrow deuterium emission line at 656.1nm. The Dichromate in a 10mm pathlength cuvette, is shown
measurement is carried out automatically. here.
10
FULL VALIDATION PROCEDURES
WIDEST ACCESSORY
ACCESSORY RANGE
ORDERING ACCESSORIES
Cell Holders Temperature Control - Water Circulation
Single cell holders - sample or reference 505 26 00 Single or micro sipette cell holder 503 36 00
Micro sipette 10mm cell holder 503 26 00 4 cell holder 202 36 16
Adjustable holder for micro cell 6600 57 00 2 x 4 cell holder, sample or reference 202 36 15
50µl ultra microcell holder 8020 39 00 6 cell holder 5500 36 15
Holder for rectangular cells up to 100mm 595 27 00 Temperature Control - Thermoelectric
Holder for cylindrical cells up to 100mm 595 26 00 Thermoelectric Control System 7400 31 00
Cell Changers Holder for single or sipette cell 8020 56 00
Auto changer for 4 or 4 + 4 cells, requires holder 9070 31 00 4 cell holder 9070 57 00
Holder for 4 x 10mm cells sample or reference 594 54 00 2 x 4 cell holder 9070 58 00
Auto changer for 6 cells, requires holder 9070 34 00 6 cell holder 9070 59 00
Holder for 6 x 10mm cells 5500 33 00 Sample Stirring
Holder for 6 x 20mm cells 5500 34 00 Electronic stirrer and sample cell holder 7200 31 00
Automatic 8 cell changer with holder 9070 32 00 Electronic stirrer and sample and reference holder 7200 32 00
4 position microcell holder 505 38 00 Gel Scanning
Sipette and Batch Sampling Gel scanner - requires trough or film holder 9070 39 00
Return sipette system, requires holder and cell 9070 21 00 Gel trough - 5mm x 100mm silica 570 07 02
10mm sipette cell 202 07 02 Printers and Cables
20mm sipette cell 202 07 51 RS232 cable for 25 pin PC with protocol manual 2021 26 00
40mm sipette cell 202 07 54 RS232 cable for 9 pin PC with protocol manual 2021 83 00
Sipette 10mm cell holder 503 26 00 Laser Printer 8000 73 01
Batch sampler for 40 samples with pump 2020 82 00 Dot matrix printer 8000 70 01
Batch sampler for 100 samples with pump 2020 82 02 Colour ink jet printer 8000 72 01
Reflectance Calibration Filters
Fixed angle reflectance accessory - pair CE 575 Holmium filter in holder 202 01 44
Variable angle reflectance accessory CE 574 Didymium filter in holder 303 01 30
Lamps Set of 2 certified Wavelength filters in holders 303 40 00
Deuterium lamp with hours indicator 2202 01 42 Set of 4 certified Absorbance filters in holders 594 44 00
Tungsten halide lamp - in pairs 2303 01 40 Set of 6 certified Absorbance filters in holders 594 66 00
11
ORDERING
ORDERING
CE 7400 Spectrophotometer
< 2nm pharma-compliant Optical
bandpass. Wavelength range 190-1100nm.
SPECIFICATIONS
SPECIFICATION
Optical System Fully symmetrical double beam system CE 7400S Spectrophotometer
1 nm Optical bandpass.
All mirrors coated for long life SPECIFICATIONS
Wavelength range 190-1100nm.
Monochromator Modified Czerny-Turner design using 1200
CE 7500 Spectrophotometer
L/mm holographic diffraction grating 0.5, 1, 2 and 4nm Optical bandpass.
Detectors Two silicon diode detectors Wavelength range 190-1100nm.
Self Test and Calibration Automatic at switch on CE 7200 Spectrophotometer
Wavelength Range and Accuracy 190 - 1100nm; 0.5nm <2 nm Optical bandpass.
Wavelength range 190-900nm.
Wavelength Reproducibility 0.1nm
Wavelength Readout Digital display on screen CE 7460/CE 7560 Dissolution Spectros
Wavelength Selection By GOTO Key and keypad entry Suitable for tablet dissolution monitoring
using a choice of dissolution software and
Optical Bandwidth < 2nm CE7400; 0.5, 1, 2, 4nm CE7500 an automatic six or eight cell changer.
Stray Light Less than 0.02% at 220nm, NaI; and 0.02%
8000 70 01 Dot Matrix Printer and Cable
at 340nm, NaNO2
Display Screen Large backlit LCD displays spectra, menus, 8000 72 01 Colour Ink Jet Printer and Cable
data, prompts and instrument status. 8000 73 01 Laser Printer and Cable
Display Scrolling Provides viewing width of 430mm
Derivative Spectra 1st to 4th derivatives SOFTWARE MODULES
Autozero Automatic by press button
Program C
Photometric Readout Digital display of A, %T and C on screen Cell program for up to 4, 6 or 8 cells
Photometric Accuracy ±.004A at 1A
Program W
Photometric Noise Less than ±0.0001A at 550nm, 2nm b/width Wavelength program for up to 10
Baseline Stored in non-volatile memory wavelengths and time interval
measurements at a fixed wavelength
Baseline Flatness ±0.001A (300nm/min, 200-1100nm) 2nm
bandwidth Quant M
Baseline Stability Better than ±0.0001A/hour Multi-wavelength assays at 2 or 3
wavelengths, Warburg and Christian
Computer Interface Bi-directional RS 232 c assays at 2 or 3 wavelengths, wine/colour
Scan Speeds 1-4000nm/min assay at up to 10 wavelengths
Wavelength Scale Expansions 1-100nm/cm Quant P
Method Storage 30 methods may be stored and retrieved Protein assays using Lowry, Bradford,
Method Protection Each protected by 4 digit passcode Biuret, BCA and direct UV
Reaction Kinetics With plots, reprocessing of data as Quant S
required, for single cell or up to 6 cells Quantification of corrected bands,
difference spectra, spectral stripping
Overlaid Scans Up to 8 scans may be overlaid
Cell Programming Up to 4, 6 or 8 cells Kinetics
Programme Cycles From 1 to 9999 Kinetic measurements with plots and
reprocessing of data
Programme Delay (cycle time) From 0 seconds to 4 days (1 sec resolution)
Wavelength Programming Up to 10 wavelengths. May be combined Kinetics M
Multi-cell Kinetics linked with
with a cell programme autochanging of cells and plotting of
Dynamic Scan Recall Last 25 scans automatically stored on board reaction curves
Storage of Spectra 100 spectra may be stored code protected
Formulae
Concentration Curve Fitting Linear, quadratic or cubic with editing of Construction and entry of mathematical
standards. 30 curves may be stored formulae with multiple wavelengths and
cells; automatic computation of results
Multi-language Operation Six languages provided
Formula Entry and Computation Complex formulae may be computed Validation
Batch Sampling Up to 100 samples under internal control Validation of absorbance, wavelength,
bandwidth, stray light etc. using liquid
Date and Time Information Printed from real time clock samples or certified standards
Power Requirements 110-250V, 50/60Hz, 170 watts.
DataStream
Dimensions and Weight 635 x 410 x 210mm; 33kg Data transfer to, or control by a PC.
Graphical presentation, transfer of data to
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice. Excel, Word etc.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND ISO 9001
TEL: 01223 420821 FAX: 01223 420475 E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com CERTIFIED COMPANY
12
ULTRA FAST SCANNING
UV-VISIBLE DETECTOR
1
Universal UV/Visible Detector
WaveQuest the ultra fast scanning Dynamic Absorbance
Detector (DAD) is a major advance in UV-Visible detector
design, offering the capabilities of a Photo Diode Array
(PDA) detector with greatly improved performance when
used for chromatogram monitoring.
The design is based on a double beam The CE4300 has a double beam optical system in which
spectrophotometer concept, with ultra fast wavelength the dispersed radiation is dynamically scanned across
scanning over the range 190-700nm. the detectors, in the manner of a UV-Visible double beam
spectrophotometer, at ultra fast speeds – up to
This dynamic scanning provides UV spectra in only 1000nm/second.
200ms, previously only possible using the static optical
system of a PDA detector. All components of the detector – monochromator, optical
system, lamp optics, detector optics and signal
Powerful signal processing software has been developed
processing software have been carefully optimised to
which enables very high quality “on-the-fly” scans to be
provide unprecedented performance in both wavelength
triggered by eluting peaks without peak degradation.
scanning and single or multi-wavelength monitoring.
Spectral data is transferred by Cecil’s DataStream
software to a PC workstation, where the same software The lower noise level when monitoring a chromatogram
offers spectral manipulation and processing, library makes accurate measurements at the highest
facilities and the export of data to applications such as sensitivities possible when measuring very low
Excel, Word etc. All data may be stored on disk. concentrations.
Eluting peaks may be integrated at the same time as The lower drift, as much as 20 times lower, gives flat
purity and peak identification is carried out. Quantitative chromatogram baselines making integration of peaks
evaluation and reporting is carried out by Cecil’s CE4900 more accurate, particularly at high sensitivities.
PowerStream software, which is combined with
DataStream software. Taper Beam Optics
Taper beam optical imaging at the flowcell, with all
One Detector Covers All UV Applications transmitted energy reaching the detector, provides
maximum energy collection. The result is minimal
A single beam Photodiode Array Detector (PDA), used for
baseline wander due to changes in the solvent refractive
method development and R & D, will often be replaced by
index during gradient formation.
a dual beam UV variable wavelength detector (VWD), for
routine monitoring, when the developed method is
adopted, because of the poor drift performance of single Performance Validation
beam PDA detectors. Their performance can be as much
as 20 times worse. WaveQuest has a double beam optical Validation of detector performance is carried out
system with very high all round performance and the conveniently, using the instruments standard software.
lowest drift available. A Holmium Oxide filter is automatically inserted in the
optical path when the calibration routine is selected.
The CE4300 is used as a high performance UV detector for
variable wavelength monitoring. WaveQuest, which is Bandwidth validation is automatic, using the Deuterium
less expensive than a PDA detector, therefore has a emission line at 656.1nm. Absorbance accuracy is
double cost advantage. checked using filters traceable to NPL standards.
2
PowerStream Software – CE4900 New Advanced Design
PowerStream is a chromatography control and data The design of the WaveQuest, CE4300, Dynamic
processing software and interface developed by Cecil Absorbance Detector is based on a double beam UV/Visible
Instruments to be comprehensive and convenient to use Wavelength Scanning Spectrophotometer concept, with an
from a single PC workstation. It provides powerful data optical system which also provides the highest
handling and system control for isocratic, binary and performance as a dual wavelength, programmable detector.
ternary HPLC systems.
The 4nm optical bandwidth, constant over the 190-700nm
DataStream software provides sophisticated spectral range, provides high quality spectral scans for easy
processing. Spectral data is transferred from the detector identification of unknown components. The digital signal
to the PC where it is graphically displayed, manipulated processing and optical and mechanical systems provide
and exported as required. ultra fast scanning and the best noise and drift
performance available. Accurate measurements at high
Chromatographic peaks are automatically scanned to sensitivities are therefore possible.
determine purity, identify components, and determine
optimum wavelengths for chromatogram monitoring – Ultra Fast Scans of Narrow Peaks
Lambda max scans. Multiple scans of peaks enable
checks to be made of peak homogeneity. The ultra high speed scanning of the WaveQuest is
shown. A very fast binary separation was carried out, on
Wavelength scans are compared with your own library to a Cecil gradient elution system 4S, of sixteen
establish the identity of unknown components. A spectral polyaromatic hydrocarbons, designated by the American
library search facility is provided. Environmental Protection Agency as priority pollutants.
The time for the elution was less than 4 minutes, using a
Visual comparison of spectra is valuable for identifying 5cm column with a 3 micron packing.
components and for comparing scans made for purity
determination. To further assist assessment, a Several of the peaks have widths at half height less than
mathematical calculation is provided, which produces a 1.5 seconds. The spectra of all peaks were displayed in
figure indicating the degree of match or similarity. real time and are shown here overlayed in groups of four.
3
Peak Impurities Revealed Dual High Performance
The outstanding performance of the WaveQuest is When a method has been developed using the CE4300
illustrated by a number of chromatographic Dynamic Absorbance Detector, the detector may be
applications described in this brochure. used as a sensitive and very stable monitor for the
application, with performance much superior to that of
The application shown here is a chromatogram of a a Photo Diode Array detector.
mixture, obtained under isocratic conditions. It
appears to be a simple three component mixture. Should the CE4300 be required for further method
development or R & D it may be replaced by the
Peak purity checks were made for each of the peaks CE4200 Variable Wavelength Monitor. This is a top
with ultra-fast “on-the-fly” scans on both the performance detector with superb noise and drift and
ascending and descending sides of each peak. is therefore recommended for detection at the very
highest sensitivities. Excellent linearity allows
Peaks 1 and 2 gave identical spectral scans but Peak 3 accurate quantification of samples at very low or high,
gave totally different spectra between the “up side” concentrations.
and “down side” scans indicating a major peak
impurity, giving rise to the scan shown in red. WaveQuest offers better sensitivity and lower
detection limits than a Photo Diode Array detector.
Despite the presence of the impurity, peak 3 appears
visually symmetric and indeed the asymmetry factor The WaveQuest represents two instruments in one, a
calculated for the peak was close to 1.00, giving no scanning spectrophotometer and a variable
indication of the presence of an impurity. wavelength detector, resulting in major cost saving.
4
Lambda Max Scans
The same trial mixture as before, which separated into
three peaks under isocratic conditions, separated into four
peaks under binary gradient conditions using an Adept
System 4S.
7
Analysis of Sugar Free Soft Drinks
The new ultra fast scanning detector from Cecil
Instruments, the WaveQuest, was used as part of an
Adept System 4S to separate, identify and quantify the
components of soft drinks.
9
Spectral Match Index
To confirm the identity of the sixteen separated peaks
shown in the fast separation, known reference standards
were injected and eluted under the same conditions as
the sample mixture.
10
Excellent Analytical
Precision
The excellent precision of the
WaveQuest, and indeed the
complete Adept Gradient System
4S, is demonstrated by 7 repeat
Component Summary
injections and elutions of the soft
drink shown here in overlay mode,
each chromatogram being offset
by 50mA.
11
Scanning Specification Ordering
Wavelength Range 190-700nm CE4300 Dynamic Absorbance Detector
Optical Bandwidth 4nm – constant Wavelength range 190-700nm, 4nm constant optical
Digital Resolution 1nm bandpass, ultra fast wavelength scan (on-the-fly)
Wavelength Accuracy 1nm with auto peak triggering.
Wavelength Reproducibility ± 0.1nm Variable wavelength monitoring, dual wavelength
operation and programmable monitoring for up to
Absorbance Range 0.001 to 3A
6 wavelengths.
Scan Speeds Up to 1000nm/s – UV scan in 200ms Complete with instruction manual, power cable,
Baseline Flatness ± 0.002A over most of range signal cable and air test cell.
Second Order Filter Fast automatic insertion at 370nm Requires flowcell to be ordered.
Noise < ± 0.5 x 10–5 A, 230nm, 2 s T/C, using air test cell
Drift < ±0.3 x 10–4 A/h, 230nm, at equilibrium using air test cell CE4051
Overlayed Scans Up to 8 scans may be overlayed Column mounting panel with column cover.
Scan Trigger Start of peak, set Abs value, point of inflection or at peak
Number of Peak Scans Up to 100 peaks for a single elution CE4050
Scan Storage Up to 100 scans password protected Column mounting panel with column cover and
Rheodyne injection valve fitted with 20µL loop.
Multiple Scans of a Peak Up to 8 scans of any peak
Used with DataStream Data to PC, PC control, scan triggering, Lambda max. Flowcells
Software scans, peak purity and purity calculation, graphical
presentation, overlay, normalisation, disk storage, library 1200 07 70 8µL x 10mm pathlength
store and search, export, and many other functions. 1200 07 71 30µL x 10mm pathlength
1200 07 72 4µL x 5mm pathlength
1200 07 73 1mm pathlength preparative flowcell
Variable Wavelength Detection Specification 1200 07 74 12µL x 7mm pathlength
Other flowcells available on request
Wavelength Range 190-700nm
Wavelength Accuracy 1nm Printers
Wavelength Reproducibility ± 0.1nm
Absorbance Range 0.001 to 3A 8000 70 01 Dot matrix printer with signal cable
Absorbance Linearity Better than 1% 0.001 – 2A 8000 72 01 Colour inkjet printer with signal cable
Optical Bandwidth 4nm – constant 8000 73 01 Laser printer with signal cable
Dual Wavelength Operation Simultaneous measurement at 2 wavelengths and ratio CE4900
Wavelength Programming Measurements at up to 6 different wavelengths with a PowerStream software – provides PC workstation
time program and selectable sensitivity control of Cecil HPLC systems and data processing
Noise ± 0.5 x 10–5 A at 230nm, 2s T/C, using air test cell of chromatograms.
Drift ±0.3 x 10–4 A/h at 230nm at equilibrium, using test cell 9000 20 00
Noise – Dual Wavelength ± 3 x 10–5 A at 250/280nm DataStream Software - required for operation of the
Drift – Dual Wavelength ± 3 x 10–4 A/h at 250/280nm, constant temperature CE4300 in conjunction with a PC. No data
processing of chromatograms.
General Specification
Optical System Double Beam
Monochromator Littrow with 1200 l/mm holographic grating
Straylight < 0.02% at 220nm and 340nm
Detectors Two Silicon Diodes
Lamp Deuterium lamp with elapsed time indicator
Taper Beam Optics All energy collected to minimise RI effects
Self Test Automatic at switch-on; continuous monitoring of key
functions
Autozero By control panel or external trigger
Time Constant 0.1 second – 10 seconds, selectable System Requirements
Wavelength Calibration Automatic at switch-on using deuterium emission line.
Display Four-line display of parameters, menus, prompts, ● Computer with Pentium class processor
wavelength, absorbance etc. ● Pentium 200 MHz or better
Fast Number Entry By use of special number keys ● Microsoft Windows XP
Event Marking From keypad or by external trigger ● Microsoft Windows 2000
Method Storage For up to 30 methods, security protected ● 128 MB of RAM or more
Automatic Power-Up/Off Pre-programmed to save warm up time ● Hard-disk space required: 15 MB
Outputs Two absorbance outputs, or absorbance and absorbance ● CD-ROM drive
ratio, parallel printer, data available to PC. ● XGA or higher resolution monitor
Inputs Event, autozero ● Monitor resolution 1024 x 768 or better
Size and Weight 365 x 290 x 140mm, 17kg
● Microsoft Mouse or compatible pointer
Power Requirements 115V or 230V, 50/60Hz, 50VA
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB4 6AZ ENGLAND
ISO 9001: 2000
TELEPHONE: 01223 420821 FAX: 01223 420475
CERTIFIED COMPANY
E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com
12
Dedicated to Water Analysis Programmed Methods
The new AquaQuest Series 4000 spectrophotometers have All instruments are completely programmed for approximately
been specially designed to cover the complete requirements 170 water analysis methods based on the proven range of
of water analysis spectrophotometers. Both visible range and Merck 'Spectroquant' test kits.
UV and visible range instruments are offered, each with or
without an integral printer for convenient presentation of Users may in addition develop their own methods and
results without the extra space required by an external calibrations to be stored in security protected memory for
printer. instant recall and use at any time.
2
000
LARGE SCREEN : COMPACT PRINTING
Informative Graphic Display USER BENEFITS
SUPERB OPERATIONAL SIMPLICITY
Menus, scans, curves and tabulated Pre-programmed Test
results are displayed on the large backlit
LCD display with contrast control. Lists
may be scrolled vertically and plots,
Merck Spectroquant Kits
WIDEST APPLICATION RANGE scans and data horizontally to give an
effective 430mm screen width. Shown User Method Storage
below is a typical wavelength scan which
may be fully viewed by scrolling, a Wavelength Scanning
SIPETTE AND AUTOMATED SAMPLING
printout of the same scan is shown
below. Operation in six languages is
provided for operator convenience. Time Plots
PERFORMANCE
Self Test and Calibration
Accurate to 3A
Stability ±0.001A/H
Straylight 0.01%
Validation Software
Traceable Standards
3
LARGE SCREEN : COMPACT PRINTING
Cooling Water
SIPETTE AND AUTOMATED SAMPLING Drinking Water
River Water
PROGRAMMED SAMPLING Beverages
Foodstuffs
PREPROGRAMMED ANALYSES Chemicals
Surface Finishing
FOR MERCK SPECTROQUANT TESTS Agriculture
Rapid Operation Convenient Sampling
Paint
Simply enter the quantitative mode Insert the 16mm tube or 10mm cell in
and follow the menus displayed on the the dual sample holder, press the 'Run' Paper
screen, selecting pathlength and the key and the result is displayed and
required analysis each at the touch of printed as required. Other holders and Pharmaceuticals
a key. The instrument is then set ready sampling techniques may be used as
for the analysis selected. required. Hydroponics
4
SUPERB OPERATIONAL SIMPLICITY
000
WIDEST APPLICATION RANGE
Curve and Line Fitting
SIPETTE AND AUTOMATEDAfitted
SAMPLING
straight line, quadratic or cubic curve may be automatically
to a set of up to 30 standards. Fits are possible either with
an intercept or forced through zero. All entries are prompted for
simplicity of operation. With the possibility of using such a large
Reaction Kinetics
Reaction Kinetics is available with reaction plots to screen and
printer. Data may be reprocessed as required. Regression
analysis is applied to the user selected portion of the reaction
plot and results are reported in Units/Litre.
Sampling Flexibility
Some of the complete range of sampling accessories are
shown. All instruments are fitted as standard with a
special dual sample holder designed to accommodate both
10mm rectangular cuvettes and 16mm reaction tubes as
supplied with many of the Merck test kits; time is saved as
no change of holder is required when changing between
the two.
5
Dedicated with speed and
convenience for Water Analysis.
Batch Sampling
Where large numbers of similar samples are to be
measured, a batch sampler is available for up to 100
samples. The pump for the system is sample
compartment mounted and under the instruments
internal system control.
8
SIPETTE AND AUTOMATED SAMPLING
000
PROGRAMMED SAMPLING
PREPROGRAMMED ANALYSES
Ordering Accessories
SAMPLE HOLDERS Part No. THERMOSTATTIIMG
Single cell holder 1010 31 00 Water flow holder for auto 4 cell changer 2020 36 15
Dual holder for 10mm cells and 16mm tubes 4002 32 00 Water flow holder for single, sipette cell 1010 33 00
Holder for 10, 20 and 50mm cells 2010 38 00 Peltier controller and 10mm cell holder 2020 31 00
Universal cell holder, 10mm cells upwards 1010 38 00 Peltier controller and 4 cell auto changer 2021 32 00
Long pathlength cylindrical cell holder 1010 39 00 Cell compartment lid and pipe port for water
CELL CHANGERS AND HOLDERS thermostatting 1010 05 00
4 cell automatic changer (no holder) 2021 34 00 PRINTERS, CABLES AND COMPUTERS
6 cell automatic changer and holder 2021 36 00 RS232c cable for PC with 25 pin outlet and
8 cell auto changer and holder 4000 37 00 protocol manual 2021 26 00
3 x (1-50mm) cell changer for water analysis 2020 35 00 RS232c cable for PC with 9 pin outlet and
4 x 10mm cell holder for auto changer 2010 24 00 protocol manual 2021 83 00
4 x 50mm holder for auto changer 2010 36 00 Printer connection cable 8000 71 00
SIPETTE, BATCH AND SIP SAMPLING Dot matrix printer 8000 70 01
Holder for 10mm sipette cell 1010 32 00 Ink jet printer 8000 72 01
Holder for sipette cells up to 50mm 2010 38 00 Print rolls and ribbon for integral printer 2020 03 20
Batch sampler for 40 samples with pump 2020 82 00 CALIBRATION FILTERS
Batch sampler for 100 samples with pump 2021 82 02 Holmium filter in holder 202 01 44
Return sipette system no cell or holder 2021 21 00 Didymium filter in holder 303 01 30
LAMPS Set of 4 certified absorbance filters in holders 594 44 00
Deuterium lamp with hours indicator 2202 01 42 Set of 6 certified absorbance filters in holders 594 66 00
Tungsten halide lamp - in pairs 2303 01 40 Set of 2 certified wavelength filters in holders 303 40 00
9
PROGRAMMED SAMPLING
PREPROGRAMMED ANALYSES
ANALYTE RANGE UNIT pl (mm) ANALYTE RANGE UNIT pl (mm)
10
PREPROGRAMMED ANALYSES
000
FOR MERCK SPECTROQUANT TESTS
ANALYTE RANGE UNIT pl (mm) ANALYTE RANGE UNIT pl (mm)
11
SPECIFICATION ORDERING
Curve and Line Fitting Linear, quadratic or cubic, with or without SOFTWARE MODULES
intercept, for up to 30 standards with curve editing
Program C
Wavelength Scanning Scan speeds up to 4000nm/min with the scan software Cell program for up to 4, 6 or 8 cells
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE CAMBRIDGE CB24 6AZ ENGLAND ISO 9001
TEL: 01223 420821 FAX: 01223 420475 E-MAIL: info@cecilinstruments.com WEB SITE: www.cecilinstruments.com CERTIFIED COMPANY
12
COMPLETE ANALYTICAL SYSTEMS
Precision Temperature
Control
Column Oven
The very precisely temperature
controlled oven accommodates
Anion and Cation columns and pre-
columns, as well as a background
suppressor cartridge with its over
pressure protection valve.
2
FOR ION CHROMATOGRAPHY
Detector – Advanced Design Chemically Suppressed Solvent
Background
The CE4710 Conductivity Detector is an entirely new
design from Cecil Instruments providing performance Sensitivity for the measurement of anions is greatly
of the very highest order due to its exceptionally low improved by reducing the conductivity of the eluent,
noise and unrivalled baseline stability. post column.
To achieve this standard of performance a very low An optional Anion Membrane Suppressor - SAMS ™ -
volume, 0.5µL, conductivity cell has been designed is available which is mounted in the column oven, in
and is operated in a precisely thermostatted series with and after the analytical column.
aluminium oven enclosure.
The suppressor may be used continuously and is
A specially designed, low dispersion, heat exchanger, regenerated by a Continuous Anion Regeneration
is also mounted in the cell enclosure preceding the System - CARS ™ - , which pumps the regeneration
detector cell. The exchanger stabilises the fluid through the post column suppressor cartridge.
temperature of the mobile phase entering the cell.
With the enclosed system controlled to better than The suppressed solvent background conductivity leads
±0.01ºC superb performance is always available. to reduced drift and noise and therefore higher
sensitivity for measurements is available.
Autozero and auto-range facilities are provided to
ensure convenience of operation. Built-in diagnostics Close Coupling to Oven
aids instrument evaluation and fault finding.
Close coupling of the detector to the oven is
The temperature controlled cell and heat exchanger important in eliminating the effects of ambient
enclosure is conveniently accessed from the side of the temperature fluctuation on results. The couplers can
detector module, as shown in the photograph. be seen on the side of the detector.
Detector Features
3
DATA PROCESSING + CONTROL
Pump-Proven Performance
The flow tubes from the columns and suppressor cartridge enter and
leave the oven enclosure through convenient self-sealing ports. The
output port to the cell thermostatted enclosure lines up with the input
connector of the enclosure, when the modular system is arranged as
shown in the photographs of the system.
The very close coupling to the detector cell leaves only about 2
centimetres of tube between the oven and the cell. With the cell and
oven operated at the same temperature, say 35ºC, drift or noise due
to ambient fluctuations is eliminated.
All the data processing procedures and power you ● Digital and analogue outputs
need are elegantly available in PowerStream
software. Digital system control is also available. ● Process signals from multiple detectors
5
FAST ACCURATE ANALYSES
Anions in Drinking Water
Nucleic acids
Fatty acids and hydroxy fatty acids
Amino acids
Dicarboxylic acids
Amino acids
Weak organic acids
Sodium in foods
Metals in soil
Azide and cyanate in explosives
Alkali metals and alkaline earths in
grain
Chromate and sulphate in electro
plating
6
WITH HIGH SENSITIVITY
Phosphoric Acid in Soft Drinks
The determination of Phosphoric acid in a cola drink, as shown here, The column oven and cell were both
required under 5 minutes using a flow rate of 1.3mL/min. at 45ºC.
Versatility
Solvent Degasser
Degasser – Optional In-line degasser
Number of Flow Paths Two, up to 3 mL/min each
Flow Path Material PTFE, PEEK ● PC with Pentium class processor
● Pentium 1 GHz or higher
System Details ● Microsoft Windows Vista, XP, 7, 8, 10
Power Requirements Total 110V or 240V, 50/60Hz, 200VA ● RAM 512 MB or higher
Stack Size 365 x 290 x 470mm (WDH) ● Hard disk space 150 MB
● CD-ROM drive
● XGA or higher resolution monitor
monitor resolution 1024 x 768 or
better
● Mouse or compatible pointing
device
● Free USB port, or RS232 serial port,
or serial to USB converter
Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice.
8
DISSOLUTION
SYSTEMS
SOLUTION TESTER
ECTROPHOTOMETER CHOICE
UBLE BEAM
NGLE BEAM
LL ACCESSORY RANGE
DERING
ECIFICATIONS
Cecil Instruments offer complete dissolution systems This is a comprehensive dissolution software package
as well as all the components of the system for control and data processing, incorporating the
individually. The dissolution tester is common to the following features:
systems and may be used in conjunction with a choice of
spectrophotometers. It is fully USP, EP and JP compliant. Storage for 100 methods; stores stirrer speed,
temperature, sampling sequence, measuring
The CE 3790 tester is provided with seven stirred wavelength etc.
round bottom, graduated, glass vessels; the eighth
position is used for stirring the thermostatted water in A time run data store for batch number, name,
the perspex bath. The water is heated by a 1000 watt operator ID, calculation details, data correction using
element and the temperature may be set between 30˚C run or pre-run blank, media evaporation etc.
and 45˚C with an accuracy of ±0.2˚C. Calculation details include theoretical maximum
absorbance, measured standard concentration,
* The CE3890 is available with 8 stirred vessels. standard measurements using linear regression and
standard concentration at known testing times.
Stirring speed may be set in the range 20-250rpm.
The stirring head is conveniently pneumatically Results are printed in tabular and graphical form
counterbalanced for easy access to the vessels and including absorbance data, milligrams or % release
paddles for adjustments. The standard paddles are of and a 95% confidence calculation is provided. The
PTFE with PTFE coated spindles. Provision is made printout may be formatted by the operator.
for accurate centring of vessels and paddles, using
test gauges, and gauges are provided for stirrer The statistical programme includes batch comparison
height adjustment. and Q1-Q3 USP acceptance test.
2
CE 7260 Spectrophotometer
This symmetrical double beam spectrophotometer
from the Aquarius series, with an 8 cell changer, has a
1.8nm optical bandwidth and is ideal for dissolution
measurements. Its stability of, ±1 x 10-4A/hour,
approximately ten times better than single beam
instruments, makes it ideal for extended
measurements such as sustained release monitoring.
Full cell and wavelength programming together with
wavelength scanning make the instrument ideal for
dissolution applications and may, when required, be
used as a high quality scanning double beam
spectrophotometer for other applications.
CE 9260 Spectrophotometer
This is a top performance double beam spectro-
photometer from the Super Aquarius Series. The
optical system is fully symmetrical and uses a high
performance end window photomultiplier as detector.
This ensures the very best performance with minimum
drift and the best possible noise performance,
particularly for low energy conditions.
CE 3021D Spectrophotometer
This is a high quality single beam spectrophotometer
from the Super Aurius series, with an 8 cell changer
and 1.8nm optical bandwidth. Its stability of 1 x 10-3
A/hour makes it suitable for dissolution monitoring,
and may be used as a general purpose or scanning
spectrophotometer if required.
UBLE BEAM
Double Beam System
GLE BEAM
Shown here is the dissolution
tester used with the CE 7260
double beam spectrophotometer;
L ACCESSORY RANGE this forms the basis from which
dissolution System 1 is formed.
Sample Compartment
4
Single Beam System
Sample Compartment
5
E BEAM
CCESSORY RANGE
ING
ICATIONS
7
CE 7260 Aquarius and CE 7460 CE 3021D Super Aurius
Size and Weight 635 x 410 x 210mm, 35kg 480 x 340 x 205mm, 18kg
The CE 9260 Super Aquarius spectrophotometer is a top performance spectrophotometer equalling or exceeding the
specification of the CE 7260 in all respects.