Sunteți pe pagina 1din 1

FLEXURAL ANALYSIS OF DOUBLY REINFORCED RECTANGULAR BEAM

based from ACI 318-14

Programmed by: ENGR. RYAN M. LAYUG | ryanmlayug@gmail.com

A. INPUT DATA

Beam Section:

350mm x 600mm, B6 - 20mm ϕ + T5 - 20mm ϕ

Beam Dimension: Strength Parameters:

b ≔ 350 mm fc' ≔ 20.7 MPa


h ≔ 600 mm fy ≔ 276 MPa

Reinforcement: Required Strength:

db ≔ 20 mm Mu ≔ 200 kN-m
ds ≔ 10 mm
concrete_cover ≔ 40 mm
layer_clear_spacing ≔ 30 mm

⎡ N_toplayer4 ⎤ ⎡ 2 ⎤
⎢ ⎥≔⎢ ⎥
⎣ N_toplayer3 ⎦ ⎣ 2 ⎦
⎡ N_botlayer2 ⎤ ⎡ 3 ⎤
⎢ ⎥≔⎢ ⎥
⎣ N_botlayer1 ⎦ ⎣ 3 ⎦

B. ANALYSIS

C. RESULT D: FIGURE

650

Bottom_Rebar_Steel_Ratio_Percentage = 1.05 % 600

Bottom_Rebar_Ductility_Percentage = 76.34 % 550

Bottom_Rebar_Ductility = “Ductile” 500

450
ϕ ⋅ Mn = 221.18 kN-m
400
Mu = 200 kN-m
350
Remark = “Safe”
300

250

top_rebar_clear_spacing = 210 mm 200

Top_Rebar_clear_spacing = “OK” 150

100
bottom_rebar_clear_spacing = 95 mm
50
Bottom_Rebar_clear_spacing = “OK”
0
0 50 100 150 200 250 300 350 400

Project Name: Owner:


Location: Civil Engineer / Designer: Page 1 of 1