Sunteți pe pagina 1din 10

Masdar Abu Dhabi.

Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

STRUCTURAL ANALYSIS
& DESIGN SUBMITTAL

DESIGN
OF
GRC & STEEL SUPPORT & FIXING
UNDULATED PANEL – TYPE 5 (BLOCK B04B)-
typical grc with steel brackets-(concrete in)

Prepared by: Approved by:

________________
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

Client
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

REVISION SHEET

Entire Document Revised  Revised Sheets Only Attached

This page is a record of all document revisions. The nature of the revision is briefly noted under "remarks", but
these remarks are not a part of the document. The revised pages become part of the original document and
shall be complied with in their entirety.

Rev. Date By Review Appr. Remarks

00 11-07-2018 MS MS - First Issue


01 28-08-2018 MS MS - Second Issue

Structural Design Summary

Title: GRC Steel Support & Fixing Design UNDULATED PANEL TYPE – 5
(Block B 04)-Typical GRC with steel brackets-(concrete in)

Rev: 01
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

Contents: Volume I – Design Criteria and Calculation

1. Introduction ……………………………………………………………………….. 1

2. Design Standards …………………………………………………………………. 1

2.1 Building Codes …………………….………………………………....….... 1

2.2 Reference Standards ......................................................................................... 1

3. Design Load Combination ….…………………………………………………….… 1

3.1 Strength Design ….....………………….………………………………….... 1

4. Gravity Loads ….…………………...................………………………………….… 2

4.1 Material Self-Weight ….....………………………………………………….... 2

4.2 Live Load ….....………………………………………….………………….... 2

5. Wind Loads ................................................................................................................... 2

5.1 Basic Parameters and Wind Pressure…..………………………………… 2

6. Material Technical Specification ……………………………………………………. 3

6.1 GRC Properties …..............................…………..........……..…….......………. 3

6.2 Thread Rod ....................……..….............……………….......………. 3

6.3 Fixing Angle ....................……..….............……………….......………. 3

7. Performance Criteria ……………………………….……………………..…………. 3

7.1 Element Deflection Limit....................…………..........……..…….......………. 3

8. Threaded Rod/Anchor................................................................................................. 3
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

APPENDICES
Description

Appendix A - GRC PANEL CLADDING DESIGN STAAD.Vi8.

Appendix B - DESIGN & CALCULATION OF GRC-PIN SUPPORT

Appendix C - DESIGN & STRENGTH CHECK FOR STEEL BRACKET

Appendix D - COEFFICIENT THERMAL EXPANSIONS OF GRC

Appendix E - DESIGN CHECKS FOR ANCHOR BOLT IN CONCRETE

Volume I - Design Criteria

Volume II - Design Drawing


Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

Volume I - Design Criteria

1. Introduction

The Structural Design Criteria document has been prepared to inform the Owner, Architect, and Engineers
to the assumptions made in the preparation of the structural design for the above mentioned project. This entails
the listing of relevant design standards, design loadings, material technical specifications and the like.
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

2. Design Standards Design stranded based on the Technical Specifications for Design, supply and Installation of
GRC facade system

2.1 Building Codes

The structure is designed to meet or exceed the minimum requirements of the following code:

Table 2-1Building Code


Building "International Building Code 2003 in Accordance with ASCE 7-02 Minimum Design
Code Loads for Buildings and other Structures"

2.2 Reference Standards

The structure is designed to meet or exceed the minimum requirements of the following
reference standard:

Table 2-2Reference Standard


Hot Rolled "Steel Construction Manual 13th Edition, ANSI-AISC 360-05 Specifications for Structural
Steel Buildings"
Wind Loads CLADDING WIND LOAD STUDY,RWDI # 1401652.(Wind Tunnel Test Study), The wind
Tunnel test procedures met or exceeded the requirements set out in section 6.6 of the
ASCE 7-05 Standard.
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

3. Design Load Combination

Load combination shall meet the specifications of International Building Code (IBC 2006) with ASCE 7-05.

3.1 Strength Design

Basic Load Combination

LC1 1.4DL Strength Check


LC2 1.2DL + 0.5WL Strength Check
LC3 1.2DL + WL Strength Check
LC4 0.9DL + 1.6WL Strength Check
LC5 DL + WL@ -Z DIRECTION Serviceability Check
LC6 DL + WL@ X DIRECTION Serviceability Check
LC7 DL + WL@ Z DIRECTION Serviceability Check

4. Gravity Loads
General design criteria for dead and live loads are given in this section.

4.1 Material Self-Weight

( GRC) 21 kN/m³

*No other dead loads are considered in this design except for its self-weight. All these loads
are generated automatically on STAAD v8i program.

5. Wind Loads

Wind Load are calculated as per ASCE 7 – 05 standards

Wind loads calculations as per ASCE – 7 Chapter 6:

Velocity pressure calculated as below:

qz = 0.00256 Kz Kd V2 Iw

Where,
Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

qz: The Velocity pressure at height “z” in lbs per square foot,

Kz: Velocity pressure exposure coefficient evaluated at height “z” and Exposures B, C or D (from Table
6-3),

Kd: Wind directionality factor, ranging from 0.85 (buildings) to 0.95 (chimneys) (from Table 6-4),

V: Basic Wind speed in miles per hour for 3-second gust at 33 ft. above ground, and

Iw: Wind importance factor, which depends on the function of the structure (from Table 6-1)

The structure is located at a height of 100 ft.

Basic wind speed assumed as 100 mph.

The co-efficients are as follows:

Kz: The height considers at 100 feet with exposure type C – hence the co-efficient is 0.99,

Kd : Wind directionality factor considered as 0.85 for Buildings,

V: Basic Wind Speed for 3-second gust at 33ft above ground = 100 mph,

Iw : Wind importance factor = 1.0.

Velocity Pressure,

qz = 0.00256 Kz Kd V2 Iw

qz = 0.00256 (0.99) (0.85) (100)2 (1.0)

qz = 21.5424 psf - (1psf = 47.88 N/m2)

qz = 1.031 KN/m2

Cladding Co-efficient = 0.80 – Wind Ward

Maximum Wind Pressure = 0.80 X 1.031 = 0.825 KN/m2

Maximum Wind Ward pressure is considered as 0.825 KN/m2

Cladding Co-efficient = 0.50 – Lee Ward

Maximum Wind Pressure Leeward = 0.50 X 1.031 = 0.516 KN/m2

Maximum Leeward Wind pressure is considered as 0.516 KN/m2

6. Material Technical Specification

The materials listed in this section are the typical materials, grades, and/ or sizes for design purposes. Refer
to the project Drawings and Specifications for the project requirements for construction.

6.1 GRC Properties


Density D = 2180 kg/m³ (21 kN/m³)

Coefficient of Thermal Expansion α = 10-20-6/ oC

Modulus of Rupture (MOR) 18 mPa


Masdar Abu Dhabi.
Typical-GRC with Steel Brackets 8/29/2018 10:24 PM

Limit of Proportionality (LOP) 7 mPa

Compressive Strength, f’c 20 mPa

6.2 Anchor Bolt

M12 SS 316

6.3 Fixing angle

Steel Grade S275

7. Performance Criteria

7.1 Element Deflection Limit

GRC Members L/360 [DL+WL]

8. Threaded Rod/Anchor Bolt

Threaded rod with mix-chemicals is used for anchoring.