Sunteți pe pagina 1din 2

Anti-Surge Valve Assembly

Valve Schematic (Globe)

4
6

COMM N.O.

N.O.

FREE FLOW
7

1
5
C2

4-20 MA

CLOSED LIMIT SW.

OPEN LIMIT SW.

S 4-20 MA

8
AIRSET
35 - 50 PSIG

Figure 8 – Anti-Surge Valve Assembly, Globe Valve

DRAWING TITLE PROJECT SHORT NAME


ANTI-SURGE SYSTEM DESIGN PEM-SAM
"THIS COPYRIGHTED WORK AND THE INFORMATION HEREIN IS PROPRIETARY TO DRAWING NO. REV SHEET
CATERPILLAR INC., SOLAR TURBINES INCORPORATED, AND/OR SUBSIDIARIES OF
EITHER. WITHOUT EXPRESS WRITTEN PERMISSION FROM CATERPILLAR INC. OR
SOLAR TURBINES INCORPORATED. ANY COPYING, DISCLOSURE, OR USE EXCEPT 3K401 - 149653 B 11 OF 29
THAT FOR WHICH IT IS LOANED, IS PROHIBITED."
Recommended Accessories

SOLAR TURBINES REFERENCE


DESCRIPTION VENDOR P/N
DRAWING NUMBER CALL OUT
Electro-Pneumatic Positioner Note 1 N/A 1
Pressure Regulator Fisher 67CFR N/A 2
Three-Way 24 VDC Solenoid
Note 3 N/A 3
Valve
Exhaust Booster Fisher 289RC 1033516-1 4
Position Transmitter Note 1 N/A 5
Needle Valve ASCO V022A1 1041929 6
Check Valve SS-CHSS-1/3 N/A 7
Headline, 360AFI-
Coalescing Filter 1043229-1 8
70C

Table 1 - Recommended Anti-Surge Valve Accessories

NOTES:
1. Electro-Pneumatic Positioner - Smart Type Positioner with 4-20mA feedback position signal and open/closed limit
switches suggested.
2. Pressure Regulator, For larger actuators a larger capacity regulator may be required to achieve desired closing speeds
(Fisher 64R /1041930).
3. Three-Way 24 VDC Solenoid Valve - Explosion/Flame-proof with necessary certification and protection to meet specific
application requirements (BIFOLD Model FP06P, VERSA Model VSG-3321, or ASCO Series NF8327).
4. Exhaust Booster - For smaller actuators the 289RC may be too large (Cv=21). May use Humphrey QE4 or QE5.
5. Position Transmitter (required if not available with positioner in Note #1), 4-20 mA Proportional to 0-100%
Close with full open and full closed relay outputs.
6. For larger actuators a needle valve with greater free flowing capacity may be required to achieve desired closing
speeds.
7. Stainless steel check valve
8. High efficiency or equivalent coalescing filter

DRAWING TITLE PROJECT SHORT NAME


ANTI-SURGE SYSTEM DESIGN PEM-SAM
"THIS COPYRIGHTED WORK AND THE INFORMATION HEREIN IS PROPRIETARY TO DRAWING NO. REV SHEET
CATERPILLAR INC., SOLAR TURBINES INCORPORATED, AND/OR SUBSIDIARIES OF
EITHER. WITHOUT EXPRESS WRITTEN PERMISSION FROM CATERPILLAR INC. OR
SOLAR TURBINES INCORPORATED. ANY COPYING, DISCLOSURE, OR USE EXCEPT 3K401 - 149653 B 12 OF 29
THAT FOR WHICH IT IS LOANED, IS PROHIBITED."

S-ar putea să vă placă și