MODULE -I
2. A) Explain with a neat sketch the reduced ambient air refrigeration system.
8) A boot-strap cooling system of 10 TR capacity is used in an aeroplane. The
ambient air temperature and pressure are 20°C and 0.85 bar respectively.
The pressure of air increases from 0.85 barto 1 bar due to ramming action of
air. The pressure of air discharged from the main compressor is 3 bar. The
discharge pressure of air from the auxiliary compressor is 4 bar. The isentropic
efficiency of each compressor is 80% while that of turbine is 85%. 50% of
enthalpy of air discharged from main compressor is removed in the first heat
exchanger and 30% of enthalpy of air discharged from main compressor is
removed in secondary heat exchanger using rammed air. Assuming ramming
action to be isentropic, the required cabin pressure of 0.9 bar and temperature
of the air leaving the cabin not more than 20°C, find: 1. The power required to
operate the system and 2. The COP of the system. Draw the schematic and
temperature-entropy diagram of the system. Take'Y = 1.4ardCp = 1kJ1<g.
K (6+14)
P.T.C.
MECH 7 - 2 (RC) -2- Illnllil 1111 11111 11111111111111 110111 IlllIII 1111
MODULE-II
3. A~ Explain the effect of sub-cooling of condensate on vapour compression system
with the help of T-S and P-H diagram.
4. A) Sketch and explain a cascade refrigeration system. Also plot cycle on T-S
and H-S diagrams.
B) A two stage compression ammonia refrigeration system with water and flash
iQtercooler and water sub-cooling operates between overall pressure limits of
. .
15 bar and 2 bar. The flash intercooler pressure is 5 Bar. The temperature of
refrigerant leavingthe water intercooler and the water sub-cooler is limitedto 20°C.
The refrigerant is dry and saturated at the inlet to the low pressure compressor.
If the load is 15 TR, find: a) coefficient of performance and
b) power required to drive each compressor. (8+12)
MODULE-III
D) Write a short not on Thermodynamic Wet Bulb Temperature. What you mean
by by-pass factor of cooling coil? (5+5+5+5)
B) Prove that the enthalpy of humid air remains constant along a wet bulb
temperature line on psychrometrjc chart.
,
11111111111111111111111111111111 11011111111111111 -3- MECH 7 - 2 (RC)
C) An air-conditioning plant is to be designed for small office for winter conditions.
Outdoor conditions = 10°C DBT
Requiredand 8°C
indoor WBT.
conditions = 21°C DBT and 50% RH Amount of air circulation = 0.3 m3/min/person,
setting capacity of the office = 100 persons. The required conditions is achieved
first by heating and then by adiabatic humidifying. Find :
i) Heating capacity of coil in kW
ii) Surface temperature if the by-pass factor of coil is 0.22 and
iii) Capacity of humidifier. (5+5+10)
MODULE-IV
D) What do you understand by effective room sensible heat factor? Explain the
procedure to draw effective room sensible heat factor line on a psychrometric
chart. (4+4+4+8)
8. The following data relates to the office air condltlorunq plant having maximum
seating capacity of 25 occupants:
,
11111111111111111111111111111111111111111111111111 -3- MECH 7 - 2 (RC)
MODULE-IV
8. The following data relates to the office air conditioning plant having maximum
seating capacity of 25 occupants:
Assuming 40% fresh air and 60% of recirculated air passing through the evaporator
coil. The apparatus due point temperature of coil is 7.5°C. Find the by-pass
factor of the coil and capacity of the plant in TR. 20