111111111111111111"11I1"111~IIIUIIIIIIIIIIIIII MECH 7 - 2 (RC)

B.E. (Mech.) (Semester - VII) (Revised 2007 - 08)


Examination, May/June 2016 .
REFRIGERATION AND AIR CONDITIONING

Duration: 3 Hours Total Marks: 100

Instructions: 1) Answer five questions in all selecting at least one question


from each Module.
2) Assume missing data if any. .
3) Use of thermodynamics charts and steam table is permitted.

MODULE -I

1. A) Discuss Industrial Applications of refrigeration and Air-conditioning.

8) Write a short note on Dry Ice Refrigeration.


C) Explain with neat sketch working principle of Vortex Tube refrigeration with
its advantages and disadvantages. (6+6+8)

2. A) Explain with a neat sketch the reduced ambient air refrigeration system.
8) A boot-strap cooling system of 10 TR capacity is used in an aeroplane. The
ambient air temperature and pressure are 20°C and 0.85 bar respectively.
The pressure of air increases from 0.85 barto 1 bar due to ramming action of
air. The pressure of air discharged from the main compressor is 3 bar. The
discharge pressure of air from the auxiliary compressor is 4 bar. The isentropic
efficiency of each compressor is 80% while that of turbine is 85%. 50% of
enthalpy of air discharged from main compressor is removed in the first heat
exchanger and 30% of enthalpy of air discharged from main compressor is
removed in secondary heat exchanger using rammed air. Assuming ramming
action to be isentropic, the required cabin pressure of 0.9 bar and temperature
of the air leaving the cabin not more than 20°C, find: 1. The power required to
operate the system and 2. The COP of the system. Draw the schematic and
temperature-entropy diagram of the system. Take'Y = 1.4ardCp = 1kJ1<g.
K (6+14)

P.T.C.
MECH 7 - 2 (RC) -2- Illnllil 1111 11111 11111111111111 110111 IlllIII 1111
MODULE-II
3. A~ Explain the effect of sub-cooling of condensate on vapour compression system
with the help of T-S and P-H diagram.

B) What is the function of a flash intercooler provided in a compound vapour


compression refrigeration system?

C) Derive an expression for.the C.O.P. of an ideal vapour absorption system. In


vapour absorption system heat is supplied to the generator at a temperature
of 90°C. The cooling in the condenser and refrigeration evaporation takes
place at 20°C and -10°C respectively. Find the maximum C.O.P. of the
system. (5+5+ 10)

4. A) Sketch and explain a cascade refrigeration system. Also plot cycle on T-S
and H-S diagrams.

B) A two stage compression ammonia refrigeration system with water and flash
iQtercooler and water sub-cooling operates between overall pressure limits of
. .
15 bar and 2 bar. The flash intercooler pressure is 5 Bar. The temperature of
refrigerant leavingthe water intercooler and the water sub-cooler is limitedto 20°C.
The refrigerant is dry and saturated at the inlet to the low pressure compressor.
If the load is 15 TR, find: a) coefficient of performance and
b) power required to drive each compressor. (8+12)

MODULE-III

, 5. A) Describe the working of an evaporative condenser.

B) When dehumidification of air necessary and how it is achieved?

C) Describe the operation of capillary tube in refrigeration systems. Why is it


preferred in household refrigerator?

D) Write a short not on Thermodynamic Wet Bulb Temperature. What you mean
by by-pass factor of cooling coil? (5+5+5+5)

6. A) Write a short note on adiabatic saturation process.

B) Prove that the enthalpy of humid air remains constant along a wet bulb
temperature line on psychrometrjc chart.

,
11111111111111111111111111111111 11011111111111111 -3- MECH 7 - 2 (RC)
C) An air-conditioning plant is to be designed for small office for winter conditions.
Outdoor conditions = 10°C DBT
Requiredand 8°C
indoor WBT.
conditions = 21°C DBT and 50% RH Amount of air circulation = 0.3 m3/min/person,
setting capacity of the office = 100 persons. The required conditions is achieved
first by heating and then by adiabatic humidifying. Find :
i) Heating capacity of coil in kW
ii) Surface temperature if the by-pass factor of coil is 0.22 and
iii) Capacity of humidifier. (5+5+10)

MODULE-IV

7. A) Describe with neat sketch Summer Air Conditioning System.

B) Describe unitary air conditioning system.

C) Sketch 'comfort chart' and show on it the comfort zone.

D) What do you understand by effective room sensible heat factor? Explain the
procedure to draw effective room sensible heat factor line on a psychrometric
chart. (4+4+4+8)

8. The following data relates to the office air condltlorunq plant having maximum
seating capacity of 25 occupants:

Outside design conditions = 34°C DBT, 28°C WBT

Inside design conditions = 24°C DBT, 50% RH

Solar heat gain = 9120 W

Latent heat gain per occupant = 105 W

Sensible heat gain per occupant = 90 W

Lighting load = 2350 W

Sensible heat load from other sources = 11 630 W

Infiltration load = 15 m3/min.


Assuming 40% fresh air and 60% of recirculated air passing through the evaporator
coil. The apparatus due point temperature of coil is 7.5°C. Find the by-pass
factor of the coil and capacity of the plant in TR. 20

,
11111111111111111111111111111111111111111111111111 -3- MECH 7 - 2 (RC)

C) An air-conditioning plant is to be designed for small office for winter conditions.


Outdoor conditions = 10°C D8T and 8°C W8T. Required indoor
conditions= 21°C DBT and 50% RH Amount of air circulation= 0.3 m3/minlperson,
setting capacity of the office = 100 persons. The required conditions is achieved
first by heating and then by adiabatic humidifying. Find:
i) Heating capacity of coil in kW
ii) Surface temperature if the by-pass factor of coil is 0.22 and
iii) Capacity of humidifier. (5+5+10)

MODULE-IV

7. A) Describe with neat sketch Summer Air Conditioning System.

8) Describe unitary air conditioning system.


C) Sketch 'comfort chart' and show on it the comfort zone.
D) What do you understand by effective room sensible heat factor? Explain the
procedure to draw effective room sensible heat factor line on a psychrometric
chart. (4+4+4+8)

8. The following data relates to the office air conditioning plant having maximum
seating capacity of 25 occupants:

Outside design conditions = 34°C D8T, 28°C WBT


Inside design conditions = 24°C D8T, 50% RH
Solar heat gain = 9120 W

Latent heat gain per occupant = 105 W

Sensible heat gain per occupant = 90 W

Lighting load = 2350 W


Sensible heat load from other sources = 11 630 W

Infiltration load = 15 m3/min.

Assuming 40% fresh air and 60% of recirculated air passing through the evaporator
coil. The apparatus due point temperature of coil is 7.5°C. Find the by-pass
factor of the coil and capacity of the plant in TR. 20