Ceiling-mounted DR 550
NAME OF PRODUCT
mA

Siemens/China, Siemens
BRAND / MANUFACTURER Shanghai Medical
Equipment
MODEL / TYPE Multix Fusion (digital)
OUTSOURCE EXTERNAL MANUFACTURE (OEM) no
PRODUCT'S REGISTRATION (AKL/AKD) AKL 21501310851
PRODUCT'S CERTIFICATION
FDA Clearance yes
CE Mark (MDD) yes
IEC Compliance (Diisi daftar standar IEC yang dipenuhi) IEC 60601
Certificate .... ISO 13485
Locally Content (Tingkat Komponen Dalam Negeri)
WHERE MARKETED Worldwide
REFERENCE OF TECHNICAL
CONFIGURATION digital ceiling-mounted x-ray
system for general
radiography complete with
patient table and bucky wall
stand
Over/under table overtable
Remote operation yes
IMAGING TOWER ceiling mounted
Longitudinal movement, cm (in) 346 cm
Lateral movement, cm (in) 220 cm
Vertical movement, cm (in) 180 cm
Maximum SID, cm (in) 346 cm (longitudinal); up to
220 cm (transverse)
Minimum SID, cm (in) min. 83 cm
Controls Color touchscreen user
interface on tube and control
console. High-performance
PC with flat panel display
and user
interface.
Table/tower movement
Kick switches at table base
for table height adjustment
and control of 8-way
tabletop float movements.
Manual movement of x-ray
tube.
Fluoroscopy -
Radiography yes
Removable grid yes
DETECTOR yes, wireless Flat Panel
Detector
Detector type Cesium iodide (CsI)
scintillator with amorphous
silicon (a-Si) technology
Detector size, cm (in) 35 cm x 43 cm
Field sizes, cm (in) 35.3 cm x 42.4 cm (active
area)
RADIOGRAPHY, SPOT FILMING
Acquisition matrix size 3072 x 2560 pixels
Maximum spatial resolution 3.6 lp/mm
Frames per second -
Acquisition bit depth 16 bits
RADIOGRAPHY, CONVENTIONAL
Digital detector yes, wireless Flat Panel
Detector
In table yes
On tower yes
Vertical, chest yes
Cross table yes
PATIENT TABLE
Maximum patient weight, kg (lb) 300 kg
Tabletop dimensions, cm (in) 240 cm x 80 cm
Lateral movement, cm (in) ±14 cm
Longitudinal movement, cm (in) ±48 cm
Vertical movement, cm (in) 51.5 cm to 95.5 cm
Minimum height, cm (in) 51.5 cm
Table tilt, ° -
BUCKY WALL STAND
Travel range From 33 cm to 173 cm,
manual, in 0 ° position
Front panel - cassette distance ≤ 4.2 cm (cassette)
≤ 4.4 cm (detector)
Bucky unit, tiltable From – 20 ° to + 90 ° with
detent at 0 ° and + 90 °
Generator power, kW 55 kW
Preferred x-ray tubes POLYDOROS/OPTITOP
Radiographic kVp 40 kV to 150 kV
Radiographic mA range 550 mA at 100 kV
Fluoroscopic kVp -
Fluoroscopic mA range -
IMAGE DISPLAY
In-room monitor size -
Cart mounted -
Overhead mounted -
Control room monitor size 19" monitor
CONNECTIVITY
DICOM yes
ACCESSORIES
Handgrips yes
Head clamps
Myelography boots
REMOTE DIAGNOSTICS yes
POWER REQUIREMENTS 3-phase 380/400V (440/480
V with additional pre-
transformer for the
generator) ± 10% at 50 Hz
or 60 Hz
OTHER REQUIREMENTS (room size, wall etc) min. 4 m x 5 m
FUNCTION Ceiling mounted general
radiology system

OTHER INFORMATION *)
*) Example : Delivery Time, Capacity of Production, Price, Delivery time 3-4 months
Commitment of Maintenance, Warranty, Discontinue/Life Warranty 1 year
Time Medical Device, etc. Preventive maintenance 2x/
year
Spareparts availability up to
10 years