Sunteți pe pagina 1din 1

300 3350 300 300 3350 300

450
450

450

1 2
C1 C1
B 450x200 BEAM B
3500

3500
3050

3050

4T12 84 20T8-82-150
3500

LINKS

450x200 BEAM

450x200 BEAM
200
450

450

3650
600 LAP

17D10-02-200B1
kicker

1000
75

17D8-09-200T1
1118
3500

3500
3050

3050

450

1000
2150

A A
200
3950 3950
200 A 450x200 BEAM A
20T8-82-150 C1 C1
WATER TANK STRUCTURE FRONT ELEVATION WATER TANK STRUCTURE SIDE/BACK ELEVATION 4T12 83 LINKS 83 83
3500
SCALE 1:50 3650
SCALE 1:50 82

300
83 83 1 2
1 2 SECTION A-A FLOOR SLAB LAYOUT
SCALE 1:25 SCALE 1:50

81
1

600 LAP
C1 C1

kicker
1000
B B

75
350 300 350

83
B1 B1
6T12-80-200
1

B1

150
DETERMINE ON SITE
AB E

(MIN. 1200mm)
SL ET 6T12-80-200 4T12 81 10T8-82-150
K R B2
IC NC STARTERS LINKS
BASE B1 1000x1000x250
3650

1000

TH CO
m 0
0m S 2
15 AS 200
L
C
80

250
C1 C1
1000X1000X250 BASE B1
A A 80
B1 B1
(4 no.) 1000
SCALE 1:25
3650
300x300mm COLUMN C1
ON 1000X1000X250 BASE
1 2 (4 no.)
SCALE 1:25
WATER TANK FOUNDATION LAYOUT
SCALE 1:50
2D12 T
3650
2D12-95 T
3
A
22D8-94-150 LINKS
D8@150
B LINKS
MIN 1200

2D12-99 B 2D12 B
D.O.S

3
200mm THICK C
MASONRY WALL LEGEND
D
TYPICAL 300x200 BEAM A - 150mm THICK GROUND SLAB CLASS 20 (1:2:4)
T10@200
8NO. THUS. TYP. BEAM SEC.
250

WITH A142 BRC MESH


3T8
SCALE 1:25. B - 1000g POLYTHENE D.P.M.
E SCALE 1:25
200 200 200
C - MIN. 300mm THICK WELL COMPACTED HAND
600
PACKED STONE BASE LAID IN 2 LAYERS OF
150mm THICK, BLINDED WITH QUARRY DUST.
TYPICAL SECTION 1-1 D - SELECTED FILL MATERIAL, WELL COMPACTED IN
Scale (1:25)
LAYERS OF 200mm THICKNESS TO 100% MDD
E - 50mm THICK BLINDING CONCRETE CLASS 15
(MIX 1:3:6)
F - SELECTED CRUSHED STONES
Civil & Structural Engineer Project Client Drawing Title Notes:
REV REVISIONS
1. CONCRETE FOR BEAMS,FIRST FLOOR SLAB & COLUMNS TO BE
Designed by: K.N.N Drawn by: K.N.N
4. MINIMUM LAPS ARE 50x DIAMETER OF THE BY
CLASS 25/20 BAR C3
KELVIN NGUGI WATER TANK STRUCRURE JOHN NGIGE 2. REINFORCEMENT TO BE HIGH YIELD SQUARE TWISTED "T"
5. ALL FOUNDATIONS TO BE TAKEN TO A FIRM CHECKED Checked by: K.N.N
FOUNDATION/GROUND FLOOR STRATA TO BY
P.O BOX 76-10303 ENGINEER'S APPROVAL. C2 Scales: AS SHOWN
LAYOUT 3. MINIMUM COVER TO MAIN REINFORCEMENT 6. THE MAXIMUM DESIGN BEARING PRESSURE CHECKED Date: JULY 2018
TO BE: IS 100KN/M ².
WANG'URU FOUNDATIONS = 50mm 7. ALL REINFORCEMENT TO BE INSPECTED BY BY
FLOOR BEAMS = 25mm THE STRUCTURAL ENGINEER BEFORE
C1
CHECKED
FLOOR SLAB = 20mm CONCRETING.
COLUMNS = 30mm BY
STAIR = 25mm C0 C DRAWING No. TK/S/D/007