Documente Academic
Documente Profesional
Documente Cultură
The three-phase commercial inverter High efficiency at all output levels Highlights
offers more flexibility and control to Flat efficiency curves ensure high − − True three-phase bridge topology for
installers who have large installations efficiency at all output levels ensuring DC/AC output converter
with varying aspects or orientations. consistent and stable performance − − Transformerless topology
across the entire input voltage and − − Each inverter is set on specific grid
The dual input section containing two output power range. codes which can be selected in the
independent Maximum Power Point field
Tracking (MPPT), allows optimal energy This device has an efficiency rating of − − Detachable wiring box to allow an
harvesting from two sub-arrays oriented up to 98.2%. easy installation
in different directions. − − Wide input voltage range
The very wide input voltage range
The TRIO features a high speed makes the inverter suitable for
and precise MPPT algorithm for real installations with reduced string size.
power tracking and improved energy
harvesting.
Additional highlights
−− Integrated string combiner with −− Outdoor enclosure for unrestricted
different options of configuration use under any environmental
which include DC and AC disconnect conditions
switch in compliance with −− Capability to connect external
international standards (S2, S1J, sensors for monitoring environmental
-S2J, -S2F and -S2X versions) conditions
− − Natural convection cooling for −− Availability of auxiliary DC output
maximum reliability voltage (24 V, 300 mA)
IN1A(+)
MPPT 1 Inverter
IN1B(+) (DC/DC) Bulk caps (DC/AC)
+ +
IN1(+) IN1C(+)
IN1D(+)
*IN1E(+) -S2 version -S2X version
Line Grid parallel
IN1 IN1 IN1 filter relay
IN1A(-)
IN1B(-) L1 L1 L1, S L1 L1, S
IN2A(+) PE PE PE
MPPT 2
IN2B(+) + (DC/DC)
+
IN2(+) IN2C(+)
IN2D(+)
*IN2E(+)
IN2 IN2 IN2
IN2A(-)
IN2B(-) OVP
IN2C(-) monitoring
IN2(-)
- -
IN2D(-)
*IN2E(-) -S2F version
Current
reading
OVP monitoring
IN1A(+)
IN1B(+)
+
IN1(+) IN1C(+) Control circuit
IN1D(+)
*IN1E(+)
IN1 IN1
IN1A(-) PMU_RS485
IN1B(-) + T/R
Standard version
1 INVERTER
-S2F version
2 WIRING BOX
* an expansion slot for future implementation of new communication systems is available
* not present on TRIO-20.0-TL
100 100
99 99
98 98
97 97
96 96
Efficiency [%]
Efficiency [%]
95 95
94 94
93 93
500 Vdc 500 Vdc
92 92
620 Vdc 620 Vdc
91 800 Vdc
91 800 Vdc
Support and service For more information please contact © Copyright 2016 ABB. All rights reserved.
ABB supports its customers with your local ABB representative or visit: Specifications subject to change without notice.