Pour Technique Instructions For Use
21. Heat to 120°F (±2) and cure for forty (40) minutes.
a. If case is not cured with proper curing time, cases will come out under-cured. Heavier cases
should be cured an additional five (5) to ten (10) minutes.
22. Cool flask and separate.
Relines and Duplications
Prepare reline or duplication as you normally would in heat curing process.
After denture is waxed to your desired detail, follow steps 1-22.
Special Note:
The hydrocolloid being used for dentures should be isolated from that being used for fabricating partials.
Investment particles contaminating the hydrocolloid mold may also cause contamination of pour acrylic.
Tamping investment has an acid in the liquids that are absorbed in the hydrocolloid. This can chemically attack
the polymer.