Sunteți pe pagina 1din 2

Motors | Automation | Energy | Transmission & Distribution | Coatings

Wind Turbine
AGW 110 / 2.1
Direct-Drive Permanent Magnet Wind Turbine
Operating Data Transformer
Model AGW 110 / 2.1 Output voltage² ) 23 kV, 33 kV or 34.5 kV
Rated power 2,100 kW Cooling Passive air cooling
Wind class (IEC 61400-1) S
Tower
Turbulence category B
Hub height 80 m, 95 m or 120 m
Cut-in wind speed 3 m/s
Modular tubular steel (80 m, 95 m) or
Cut-out wind speed 20 m/s Type
concrete (120 m)
Operation temperature range From -10 ºC to 40 ºC Nacelle access Lift and service ladder

Rotor Additional Information


Rotor diameter 110 m Service life 20 years
Swept area 9,503 m² Control system PLC and MPU
Variable speed with electric drive pitch SCADA system Wind Power SCADA
Power regulation control (independent per blade, including
ultra capacitor backup) Built-in in blades, rotor and tower, in
Lightning protection
compliance with IEC 61400-24
Generator
Grid codes Complies with international regulations
Type Synchronous with permanent magnets
Onboard crane hoist lift capacity 700 kg, inside the nacelle
Drive train Direct drive (no gearbox)
50/60 Hz, inland, marine environment,
Grid connection Full power converter Optional low temperature, high temperature,
Cooling Thermal fluid aviation lights, aviation markings
Stator impregnation VPI (Vacuum Pressure Impregnation) Power Curve
Converter 2.200
2,200
2.000
2,000
Type Full conversion, Type 4 (IEEE) 1.800
1,800
Output voltage 690 V 1.600
1,600
Power (kW)

1.400
1,400
Frequency 50 Hz or 60 Hz
1.200
1,200
Power factor¹) 0.95 IND - 0.95 CAP 1.000
1,000
Cooling Liquid cooling 800
800
600
600
Nacelle 400
400
200
200
Yaw system Active, driven by electric gear motors
00
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Main brake Aerodynamic (blade feathering) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Wind speed (m/s)
Secondary brake Electromechanical Air density, pair=1.225 kg/m³
Auxiliary brake Electromechanical lock pin Notes: 1) P
 ower factor at converter output terminals, before transformer
Open (standard) for inland environment input terminals (low voltage side).
Ventilation
Closed (optional) for maritime environment 2) Other transformer output voltage available on request.

The values shown are subject to change without prior notice.


Cod: 50049460 | Rev: 01 | Date (m/y): 11/2016

WEG Group - Energy Business Unit


Jaraguá do Sul - SC - Brazil
Phone: +55 47 3276 4000
energia@weg.net
www.weg.net