Documente Academic
Documente Profesional
Documente Cultură
Wind Turbine
AGW 110 / 2.1
Direct-Drive Permanent Magnet Wind Turbine
Operating Data Transformer
Model AGW 110 / 2.1 Output voltage² ) 23 kV, 33 kV or 34.5 kV
Rated power 2,100 kW Cooling Passive air cooling
Wind class (IEC 61400-1) S
Tower
Turbulence category B
Hub height 80 m, 95 m or 120 m
Cut-in wind speed 3 m/s
Modular tubular steel (80 m, 95 m) or
Cut-out wind speed 20 m/s Type
concrete (120 m)
Operation temperature range From -10 ºC to 40 ºC Nacelle access Lift and service ladder
1.400
1,400
Frequency 50 Hz or 60 Hz
1.200
1,200
Power factor¹) 0.95 IND - 0.95 CAP 1.000
1,000
Cooling Liquid cooling 800
800
600
600
Nacelle 400
400
200
200
Yaw system Active, driven by electric gear motors
00
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Main brake Aerodynamic (blade feathering) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Wind speed (m/s)
Secondary brake Electromechanical Air density, pair=1.225 kg/m³
Auxiliary brake Electromechanical lock pin Notes: 1) P
ower factor at converter output terminals, before transformer
Open (standard) for inland environment input terminals (low voltage side).
Ventilation