Sunteți pe pagina 1din 2

Reactions from Steel Structure Design

Load Description Max Horizontal (kN) Max Vertical (kN)


Dead Load 0 6
Live Load + Mezzanine 1 8
Collateral Load 0 2
Wind Load1 -12 -21
Wind Load2 12 0
Wind Load3 -15 -16
Wind Load4 9 5
Wind Load5 5 -11
Wind Load6 2 -6

Max Additional loads

Block work of height 2.5 m


Block work of Length 7.2 m
Weight from Block Work 81 kN
Size of Tie Beam 200 2100
Length 7.2 m
Self Weight of TB 76 kN

Design Loads considered in Prokon Analysis:

Load Description Max Horizontal (kN) Max Vertical (kN)


DL +LL+CL+BW+TB 1.00 172.60
DL +LL+CL+0.75WL1+TB -8.00 75.85
DL +LL+CL+0.75WL2+TB 10.00 91.60
DL +LL+CL+0.75WL3+TB -10.25 79.60
DL +LL+CL+0.75WL4+TB 7.75 19.75
DL +LL+CL+0.75WL5+TB 4.75 7.75
DL +LL+CL+0.75WL6+TB 2.50 11.50
DL +0.75*LL+CL+0.75WL1 -8.25 -1.75
DL +0.75*LL+CL+0.75WL2 9.75 14.00
DL +0.75*LL+CL+0.75WL3 -10.50 2.00
DL +0.75*LL+CL+0.75WL4 7.50 17.75
DL +0.75*LL+CL+0.75WL5 4.50 5.75
DL +0.75*LL+CL+0.75WL6 2.25 9.50
0.6 DL +WL 1 -12.00 -17.40
0.6 DL +WL 2 12.00 3.60
0.6 DL +WL 3 -15.00 -12.40
0.6 DL +WL 4 9.00 8.60
0.6 DL +WL 5 5.00 -7.40
0.6 DL +WL 6 2.00 -2.40
DL+LL+CL+BW+TB
DL+LL+CL+0.75WL1+TB
DL+LL+CL+0.75WL2+TB
DL+LL+CL+0.75WL3+TB
DL+LL+CL+0.75WL4+TB
DL+LL+CL+0.75WL5+TB
DL+LL+CL+0.75WL6+TB
DL+0.75LL+CL+0.75WL1
DL+0.75LL+CL+0.75WL2
DL+0.75LL+CL+0.75WL3
DL+0.75LL+CL+0.75WL4
DL+0.75LL+CL+0.75WL5
DL+0.75LL+CL+0.75WL6
0.6 DL +WL 1
0.6 DL +WL 2
0.6 DL +WL 3
0.6 DL +WL 4
0.6 DL +WL 5
0.6 DL +WL 6
DL+CL+S

S-ar putea să vă placă și