OKTIS - 2
User Manual
WWW.OKTIS.RU
This translation was made by the Chamber of Commerce and Industry of
the Vladimir Region. 2016
11
USER INFORMATION
REPAIR REQUEST FORM
The meter is easy to use, and you will easily see it for yourself. for warranty repair of OKTIS-2
The unique feature of the meter is that you may check
Please make warranty repair of OKTIS-2 meter
octane number in the moment of filling fuel at the gas station. Factory number ___________________
After filling 2 - 5 liters in the tank through the metering pipe of the Fault description:
meter, you may decide if you should fill more or not if, when buying AI-95, ___________________________________________________________
your meter shows that its octane number is, for example, 88,0. Most ___________________________________________________________
probably, this gas station is selling fuel with octane number artificially ___________________________________________________________
increased with octane-increasing additives. Practice shows that acceptable ___________________________________________________________
deviation of octane number is within ±1.5 units of the number claimed by ___________________________________________________________
the gas station.
In case you always buy gasoline at the same gas station, periodically Information on meter owner:
checking your fuel helps you be sure that its quality remains the same, or Family name
reveal a sudden change of gas characteristics. First name
Patronymic
Postal code
Region
Rayon
City, settlement
Street , Building Apart.
Phone
Thank you for your interest to our meter; before use, please E-mail address
read first of all sections 1, 4, 6 and 7.
Meter delivery kit is as per with Section 3 of this manual.
Owner _____________ (signature) Date _____________
Please mail your meter with filled request form at the address:
OOO KAMELIT, p.o. Box 12, Vladimir, 600028
NOTICE: Always install batteries with ВКЛ/ВЫКЛ. (ON/OFF) Please by email to info@oktis.ru your notification on mailing your meter
button 5 in ВЫКЛ. ( OFF) position. and Russian Postal Service tracking number (14 digits).
11 10
ADDITIONAL INFORMATION 3
1. PURPOSE
To set the meter in expanded mode, after pressing button ‘5’ and the
appearance of a ticker bar in the middle of the display, using a thin object, press OKTIS-2 is intended for the determination of motor gasoline octane
button 8 “CORR”. number in Russian gasoline standards AI-80, AI-92, AI-95 and AI-98.
Ticker tape messages will appear in the lower display. Further, with a 2-3 sec Principle of meter operation is based on the dependence between dielectric
interval
permeability of gasoline and its research octane number (RON).
the following data will be displayed:
• measured value in nominal units;
The meter can operate in 2 modes: in continuous-flow mode while
• measured value in nominal units with correction for gas temperature; filling car tank at the gas station and in sensor immersion mode.
• gasoline temperature; The meter is used as an indicator permitting the car owner to obtain
• gasoline research (octane) number (RON) with correction for gas temperature.
information on the main parameter of gasoline quality.
If in course of meter operation after the ticker bar a fixed 3-element bar will
appear in the middle of the display, it means that electrical conductivity of the The meter IS NOT INTENDED for use as a measuring instrument
gasoline is above the limit due to the presence of impurities (e.g. water). We do not when resolving disputes concerning gasoline quality at the gas station.
recommend filling such gas in the tank, especially, in winter.
In Section 11 you can see a figure placed in brackets. It characterizes the 2. TECHNICAL SPECIFICATIONS
condition of dry sensor in the air and is entered in meter memory prior to its
calibration. This figure is specific for each meter. If you want to check it, please
Range of measured octane levels 70 to 110
switch on a dry meter in the air and set it into expanded mode. The meter will
check sender condition. Measured value in nominal units with correction for gas Minimum quantity of gas required for octane number
temperature shall correspond to the figure in brackets. If the two figures are not the determination in continuous-flow mode 2-5l
alike, wash the sensor and /or use measurement program correction mode. Time required to prepare the meter for operation, sec not more than 15
Minimum quantity of gas required for octane number
NOTE: To remove from sensor deposits formed due to gasoline determination in sensor immersion mode 80 ml
evaporation, it is recommended to clean the sensor (see p.8) at least once in Power supply voltage (two AA batteries) 3V
two months or more often, depending on the frequency of meter use.
Consumed current not exceeding 100 mА
Operating conditions:
According to Letter of 23.03.09 № 101-кс/616 from Russian - temperature of checked gasoline 0°С to +50°С
Research Institute of Certification the meter does not require - incumbent temperature -10°С to +40°С
compulsory certification in GOST R Certification System. - humidity at 30°С, % 30 to 80
Mass not exceeding 0,36 kg
9 8
8. TROUBLESHOOTING. When gasoline reaches sensor in tube 3, sensor parameters are changing;
microprocessor compares them with data stored in memory, and digital
If, after the meter is switched on, ticker bar instead of '00' displays a display 4 shows figures corresponding to gasoline octane number. Meter is
stationary three-element message, it means that meter sensor in tube 3 is not switched ON by pressing button 5 once, until it locks. Repeated pressure
fit for work (metal chips, dust, drops of water, or other foreign matter). In on the button switches the meter off.
this case, wash the sensor in metering tube 3 in gasoline, shake off the Microprocessor program supports basic mode, expanded mode, reading
remaining drops, purge with air, and dry. For the complete removal of correction for gas temperature mode and reading correction for sensor
contamination after washing, you may use paper strips. Sensor may be contamination mode.
washed in rectified rubber solvent gasoline (NEFRAS-S2-20\120
TU38.401-67-108-92) KALOSHA by repeated dipping of the tube in a
vessel containing gasoline; gasoline level in the vessel should be above
mark 7. After '00' appears in the display, the meter is ready for work.