Documente Academic
Documente Profesional
Documente Cultură
HD4096 12-bit
oscilloscope 16x Closer to Perfect
Conventional 8-bit
oscilloscope
Analog signal
2
EXPERIENCE THE DIFFERENCE
8-bit 12-bit
A A
B C B
C
A Clean, Crisp Waveforms | Thin traces show the actual waveform with minimal noise interference
B More Signal Details | Waveform details can now be clearly seen on an HD4096 12-bit oscilloscope
C Unmatched Measurement Precision | Measurements are more precise and not affected by quantization noise
3
POWERFUL, DEEP TOOLBOX
4
A
B
A
B
B
A
B MOST COMPLETE SERIAL DATA DEBUG AND VALIDATION
AN CAN FD USB2 I2C SPI UART RS-232 FlexRay LIN CAN CAN FD USB2
Serial Data
raph
I2CI2C SPI
SPI UARTT RS-232
UART RS-232
FlexRayFlexRay
LIN LIN
CAN CANFD
CAN CAN FD
USB2 USB2
Protocol
Eye Diagram
UART RS-232 FlexRay LIN CAN CAN FD USB2
Measure/G
ProtoSync
Support
QualiPHY
UART RS-232 FlexRay LIN CAN CAN FD USB2
Decode
Trigger
FlexRay LIN CAN CAN FD USB2
2
CLIN SPICAN CAN FD
UART USB2 FlexRay
RS-232 LIN CAN CAN FD USB2
I2C • • • •
Computing
Embedded
SPI • • • •
UART-RS232 • • • •
Trigger Decode
USB2-HSIC •
Powerful, flexible triggers designed Decoded protocol information is color-
CAN • • • •
by people who know the standards, coded to specific portions of the serial
• • • •
Automotive + Industrial
CAN FD
with the unique capabilities you want data waveform and transparently
to isolate unusual events. Conditional overlaid for an intuitive, easy-to- FlexRay • • • •
data triggering permits maximum understand visual record. All decoded LIN • • • •
flexibility and highly adaptable error protocols are displayed in a single time- SENT •
frame triggering is available to isolate interleaved table. Touch a row in the
MOST50/150 •
error conditions. Efficiently acquire interactive table to quickly zoom to a
bursted data using Sequence Mode to packet of interest and select a column BroadR-Reach •
maximize the oscilloscope's memory header to create filter criteria, as is ARINC429 • • •
Avionics
usage. Sequence Mode enables the commonly done in spreadsheets. Easily MIL-STD-1553 • • • •
oscilloscope to ignore idle time and search through long records for specific SPACEWIRE •
acquire only data of interest. protocol events using the built-in search Ethernet
feature. (10/100Base-T)
• •
Ethernet
(1000Base-T)
•
High Speed Computing,
• • • • • •
Storage +Peripherals
USB 1.1/2.0
MD10 •
8b/10b • • •
Fibre Channel •
SATA (1.5 & 3 Gb/s) • • •
SAS (1.5 & 3 Gb/s) • •
PCI Express (Gen1) • •
Measure/Graph Eye Diagram LPDDR2 • •
Memory
Quickly validate cause and effect with Rapidly display an eye diagram of
DDR2 • •
automated timing measurements to or your packetized low-speed serial data DDR3 • •
from an analog signal or another serial signal without additional setup time. D-PHY/CSI-2/DSI • • •
message. Make multiple measurements Use eye parameters to quantify system DigRF3G • •
in a single long acquisition to quickly performance and apply a standard or
DigRFv4 • •
acquire statistics during corner- custom mask to identify anomalies.
MIPI
case testing. Serial (digital) data can Mask failures can be indicated and can
UniPro •
be extracted to an analog value and force the scope into Stop mode. M-PHY • •
graphed to monitor system performance SPM •
SDAII or DDR Debug (optional) create
over time, as if it was probed directly. Audio (I²S, LJ, RJ, TDM) • • •
eye diagrams of streaming NRZ serial
Complete validation faster and gain
Other
5
12-BIT UP TO 8 GHz, 20 GS/s, 5 GPTS
With up to 5 Gpts of acquisition memory, WavePro HD 12-bit oscilloscopes capture events occurring over long periods
of time, while still maintaining high sample rate for visibility into the smallest details.
Longest memory
WavePro HD oscilloscopes contain a
sophisticated acquisition and memory
management architecture that makes
5 Gpt acquisitions fast and responsive.
More memory means more visibility into
system behavior.
Simple navigation
Long memory and high sample rates
capture both millisecond-scale trends
and picosecond-scale glitches.
WavePro HD oscilloscopes are equipped
with an advanced user interface that
makes it easy to find features, navigate
directly using timebase scale and
position knobs, or set up zoom traces –
whichever you prefer. Apply analysis
tools easily to any type of trace.
No compromise
WavePro HD can acquire 250 ms of data
at full 20 GS/s sample rate – and always
with 12 bits of resolution. Oscilloscopes
with less memory require trading off
sample rate for acquisition time.
WavePro HD
5 Gpts @ 20 GSs/s
250 ms acquisition time
Competitor A, 20 GS/s
100 ms acquisition time
Competitor B, 20 GS/s
40 ms acquisition time
7
10-BIT UP TO 4 GHz, 40 GS/s
HDO8000A
HD 8-Channel Oscilloscopes
up to 1 GHz, 10 GS/s
HDO8000A High Definition
Oscilloscopes have more channels,
more resolution, more bandwidth
and more memory than any other
midrange oscilloscope. Ideal for
debugging and troubleshooting
three-phase power electronics, auto-
motive electronics, and embedded/
mechatronic designs with high
True 12-Bit Technology Q-Scape Multi-Tab Display
resolution sensor signals.
Architecture
Comprehensive digital logic (MSO), HD4096 high definition technology
low-speed serial data trigger, decode consists of 12-bit ADCs with 10 GS/s More waveforms requires new display
sample rates, high signal-to-noise architectures. Unique Q-Scape multi-Tab
and analysis toolsets, and the widest
(55dB) input amplifiers and a low-noise display architecture speeds the under
variety of probes and application
system architecture. This technology standing of your design with 4x the
packages complete the solution.
enables high definition oscilloscopes display area. Quickly move waveforms
Get the most intuitive long-memory
to capture and display signals of up to to different tabs through drag-and-drop.
analysis using the unique Q-Scape
1 GHz with 16 times more resolution Extended desktop supports WQXGA
multi-tab display architecture. than conventional 8-bit oscilloscopes. 3840 x 2160 pixel displays.
9
12-BIT 8 CHANNEL MOTOR DRIVE ANALYSIS
MDA800A Series
Key Features Complete Drive System Debug digital (pulse) tachometers, Brushless
The Motor Drive Analyzer acquires drive DC (BLDC) Hall sensor, Quadrature
●● Complete Motor Drive System
Debug and Validation in power section, power transistor, and Encoder Interface (QEI), and Resolvers.
One Instrument embedded control system signals, and Additionally, Hall sensor and QEI signals
●● Three-Phase Power Measurements; performs three-phase power analysis of can be integrated through digital
Real, Apparent, Reactive Power the power section waveforms. inputs, preserving valuable analog input
●● Efficiency Measurements Correlation of drive system behaviors to channels for other signals.
●● User-Configurable Power Table embedded control loop signals enables
●● Two- and Three-Wattmeter Methods debug and analysis of all aspects of the
supported complete motor drive.
●● Per-Cycle Time-Correlated
Waveforms From Power Values Numerics Measurement Table
●● Harmonics Calculations and Filtering Various voltage, current, power (real,
(optional) apparent, and reactive), phase angle/
●● Dynamic Drive Response Analysis, power factor, and efficiency parameters
From Startup To Overload are calculated on acquired voltage and
●● Unique Zoom+Gate Mode current waveforms and displayed in a Detailed Waveforms
●● Line-Line To Line-Neutral Voltage table. The table is displayed along with In addition to the mean table values,
Conversion the acquisition waveforms. a waveform showing any per-cycle
●● Up to 6000 VRMS Isolation with measurement parameter variation can
HVD Series Differential Probes Zoom+Gate Dynamic Analysis be displayed by simply selecting a table
●● Easily Interface Other Capture long acquisitions and Zoom+ value. This waveform is time-correlated
Current Measurement Devices Gate with instant table value updates with other waveforms acquired by the
●● Complete Motor Integration and views of dynamic three-phase MDA800A oscilloscope and can be
(Torque, Speed, Position) power and motor drive performance. used to correlate complex drive beha-
●● Flexible Setup Capability viors to other control or power system
Most Complete Motor waveforms, and to debug drive system
●● Graphical User Interface
Mechanical Integration problems. Statistical detail of the mea
Simple integration is provided for surement set can also be displayed. This
nearly any type of speed, rotation or additional information goes well beyond
position sensor, including analog and what is provided by a Power Analyzer.
10
12-BIT UP TO 1 GHz
HDO6000A
Highly Accurate
Measurements with
12-Bit HD Oscilloscopes
up to 1 GHz, 10 GS/s
HD06000A uses Teledyne LeCroy’s HD4096 high definition true 12-bit technology, long memory, a compact
form factor, 12.1” touch screen display, powerful measurement and analysis tools, and mixed signal capability.
It is the ideal oscilloscope for circuit validation, system debug and waveform analysis.
The powerful feature set provides analytical tools and unique application packages to streamline the testing
process. Tools such as WaveScan Search and Find and History Mode, combined with advanced triggering, identify
and isolate problems while Spectrum Analyzer Mode provides analysis tools in the frequency domain.
1 GHz bandwidths
●● 10 GS/s Sample Rate
›
Designed for touch
›
Built for simplicity
›
Made to solve
●● Multi-language user interface
report generation
●● History Mode
signal capability, the HDO4000A is the ideal oscilloscope for precise measure- ●● 16 digital channels with 1.25 GS/s
ments and fast debugging. Tools such as WaveScan Search and Find, ›
Analog and digital cross-pattern
triggering
LabNotebook Report Generator, and History Mode help to identify and to
›
Digital pattern search and find
isolate problems for faster troubleshooting.
›
Analog and digital timing
measurements
The 10 GS/s, 50 Mpts architecture ›
Activity indicators
provides the ability to capture a fast
transient or a long acquisition.
SAM40
The SAM40 provides up to 24 input channels for low frequency (sensor signal)
acquisition and analysis. It connects to a 4 or 8 channel Teledyne LeCroy
12bit resolution high definition oscilloscope (HD4096 HDOs and MDAs) to provide
Analog+Digital+Sensor (up to 8+16+24 channel) acquisitions.
12
20 GHz – 100 GHz
LabMaster 10 Zi-A
Key Features
●● Up to 100 GHz bandwidth, 240 GS/s
sample rate, 80 Ch, 1.5 Gpts/Ch of
analysis memory
●● Modular – start with four channels
and expand your system over time
●● Wide bandwidth upgrade range The LabMaster 10 Zi-A series of real-time oscilloscopes boasts the world’s
provides investment protection highest bandwidh and fastest sampling rate at 100 GHz and 240 GS/s. This
●● Single trigger circuit for all modules world-leading performance is key to acquiring, analyzing and understanding
eliminates additive trigger jitter
the fastest phenomena found in R&D labs, where engineers are working
●● Simple – connect and acquire – on next-generation communication systems, high bandwidth electrical
Teledyne LeCroy has done the hard
work for you components and fundamental scientific research.
WaveMaster 8 Zi-B
Key Features
●● Up to 30 GHz bandwidth,
80 GS/s sample rate, 512 Mpts/Ch
of analysis memory
●● The industry’s only true hardware
14.1 Gb/s serial pattern trigger
●● Low Jitter Measurement Floor and
exceptional timebase stability
●● Comprehensive set of serial data
analysis, debug, validation and
compliance tools
●● Integrated 50 Ω and 1 MΩ inputs
for true connection and probing
flexibility
WaveMaster 8 Zi-B combines high bandwidth and high sample rate with ●● Multi-lane serial data eye, jitter and
superior signal fidelity performance and 20 GHz on all four input channels. crosstalk analysis
Availability of models from 4 to 30 GHz with complete bandwidth ●● Real-time de-embedding, emulation,
upgradability throughout the entire product range makes it easy and and equalization
affordable to stay current with emerging high-speed technologies and ●● 15.3” touch screen display
serial data standards.
HDA125
HighSpeed
Mixed Signal Testing
Key Features
●● 12.5 GS/s sampling rate for 80 ps
timing accuracy
●● 3 GHz leadset for capturing digital
signals up to 6 Gb/s
●● Unique QuickLink probing system The HDA125 transforms your oscilloscope into the highest-performance,
› Easy access to difficult test points most flexible mixed-signal solution for high-speed digital debug and
with differential solderin tips evaluation. With 12.5 GS/s digital sampling rate on 18 input channels, and
with 9inch lead
› Ultra low loading for superior
the revolutionary QuickLink probing solution allowing seamless transitions
from digital to high-bandwidth analog acquisitions, validation of challenging
performance
› Unmatched acquisition flexibility interfaces such as DDR4 has never been simpler or more comprehensive.
14
500 MHz – 4 GHz
WaveRunner 8000
40 GS/s sample rate, long memory, MAUI – Most Advanced User Interface,
›Device and Switching Power
●● Supply Analysis
and a versatile toolset make the WaveRunner 8000 unbelievably powerful
› Comprehensive set of serial data
and incredibly easy to use. analysis, debug, validation and
compliance tools
Exceptional Serial Data Tools ●● 16 digital channels with 1.25 GS/s
A wide variety of application packages › Analog and Digital
are available to meet all serial data test CrossPattern Triggering
› Digital Pattern Search and Find
›
challenges, ranging from automated
Analog and Digital Timing
compliance packages to flexible debug
Measurements
toolkits. A suite of protocol specific
› Logic Gate Emulation
measurements and eye diagram pack- › Activity Indicators
ages are available to complement the
industry’s most intuitive trigger and
Superior User Experience decode packages.
15
1 GHz
WaveSurfer 510
1 GHz Oscilloscope
The WaveSurfer 510 combines the MAUI
with OneTouch user interface with powerful
waveform processing, in addition to advanced
math, measurement, and debug tools, to
quickly analyze and find the root cause of
problems. The 12.1” touch-screen display of
the WaveSurfer 510 is the largest in its class
and makes viewing waveform abnormalities
fast and easy.
16
100 MHz – 1 GHz
WaveSurfer 3000z
17
OSCILLOSCOPES
Channels Up to 80 4 4
MSO Characteristics – 18/36 Ch Low Speed 1)
16 Ch 3)
9/18 Ch High Speed 4)
Display 15.3" WXGA Color Touch Screen 15.3" WXGA Color Touch Screen 15.6” Full HD Color Touch Screen
Memory 32 Mpts/Ch to 1.5 Gpts/Ch 64 Mpts to 512 Mpts/Ch 100 Mpts/Ch to 5 Gpts/Ch
Sample Rate Up to 240 GS/s Up to 80 GS/s Up to 20 GS/s
Trigger Types Basic, SMART, Sequence, Basic, SMART, Sequence, Basic, SMART, Sequence,
High Speed Serial Protocol, High Speed Serial Protocol, High Speed Serial Protocol,
Measurement Measurement Measurement
Serial Data Options 37 37 37
Dimensions (HWD) MCM-Zi: 277 x 462 x 396 mm 355 x 467 x 406 mm 345 x 445 x 196 mm
LabMaster 10-xxZi Acq. Module:
202 x 462 x 660 mm
HDO4000A/
HDO4000A-MS WaveSurfer 510 WaveSurfer 3000z
Classification High Definition Analysis Bench Bench
Bandwidth 200 MHz to 1 GHz 1 GHz 100 MHz to 1 GHz
Resolution 12-bit ADC resolution, 8-bit ADC resolution, 8-bit ADC resolution,
15bit with ERES 11bit with ERES 11bit with ERES
Channels 4 4 4
MSO Characteristics 16 Ch 2) 18 Ch or 36 Ch 1) 16 Ch 3)
Display 12.1” WXGA Color Touch Screen 12.1” WXGA Color Touch Screen 10.1” Color Touch Screen
Memory 25 Mpts/Ch to 50 Mpts/Ch 16 Mpts/Ch to 32 Mpts/Ch 20 Mpts/Ch
Sample Rate 10 GS/s (12bit) 10 GS/s Up to 4 GS/s
Trigger Types Basic, SMART, Sequence Basic, SMART, Sequence Basic, SMART, Sequence
Serial Data Options 23 23 6
Dimensions (HWD) 291 x 399 x 131 mm 316 x 417 x 238 mm 220 x 350 x 145 mm
1)
compatible with MS250/500 Options 2) MS Models 3) 16 Digital Channels with MSOption 4) HDA125 Option
18
Learn More: teledynelecroy.com/oscilloscope
HDO8000A/ HDO6000A/
WaveRunner 8000 HDO9000 MDA800A HDO6000A-MS
Advanced Advanced 8-Channel Advanced
Analysis High Definition Analysis High Definition Analysis High Definition Analysis
500 MHz to 4 GHz 1 GHz to 4 GHz 350 MHz to 1 GHz 350 MHz to 1 GHz
8-bit ADC resolution, 10-bit ADC resolution, 12-bit ADC resolution, 12-bit ADC resolution,
11bit with ERES up to 13.8-bit with 15bit with ERES 15bit with ERES
optimized filtering
4 4 8 4
16 Ch 3)
16 Ch 3)
16 Ch 3)
16 Ch 2)
9/18 Ch High Speed 4)
12.1” WXGA Color Touch Screen 15.4” WXGA Color Touch Screen 12.1” WXGA Color Touch Screen 12.1” WXGA Color Touch Screen
32 Mpts/Ch to 128 Mpts/Ch 128 Mpts/Ch 50 Mpts/Ch to 250 Mpts/Ch 50 Mpts/Ch to 250 Mpts/Ch
Up to 40 GS/s Up to 40 GS/s 10 GS/s (12bit) 10 GS/s (12bit)
Basic, SMART, Sequence, Basic, SMART, Sequence, Basic, SMART, Sequence, Basic, SMART, Sequence,
Measurement Measurement Measurement Measurement
37 37 24 24
316 x 417 x 238 mm 358 x 445 x 242 mm 374 x 417 x 280 mm 291 x 399 x 131 mm
4 HDA125
–
12.5 GS/s HighSpeed Digital Analyzer with 18 ch
7.5" Color Touch Screen
QuickLink leadset for the following oscilloscope series:
5 Mpts/Ch
2 GS/s WM8Zi-B, WR6Zi, HDO9000
Standard
3
190 x 295 x 102 mm
19
OSCILLOSCOPE PROBES
The right probe is essential for accurate signal capture. Teledyne LeCroy offers an extensive range of probes
to meet virtually every probing need.
WaveRunner
WaveMaster
WaveSurfer
LabMaster
ically scale the oscilloscope waveforms
WavePro
WaveJet
without user input. Passive probes are the
HDO
ideal tool for low frequency signals since
PP006A/C 500 MHz, 10:1, 10 MΩ, 600 V Passive Probe n
circuit loading at these frequencies is
PP019 250 MHz, 10:1, 10 MΩ, 500 V Passive Probe n
minimized. Passive probes are designed
PP020 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n
to handle voltages of up to 400 V, some as
PP021 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n n n
high as 600 V.
PP022 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n n
PP023 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n n
PP024 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n n
PP025 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n nnn
PP026 500 MHz, 10:1, 10 MΩ, 500 V Passive Probe n
WaveMaster
WaveSurfer
HDO
WaveMaster
WaveSurfer
WaveMaster
LabMaster
WavePro
WaveJet
WaveMaster
LabMaster
WavePro
WaveJet
20
Learn More: teledynelecroy.com/probes
WaveRunner
WaveMaster
small signals (gate-drives, sensors, etc.)
WaveSurfer
LabMaster
WavePro
WaveJet
floating on an HV bus in power electronics
HDO
designs, or for EMC, EFT, ESD, and
HVFO103 60 MHz, Superior Noise and Rejection nnnnnn RF immunity testing sensor monitoring.
(140 dB CMRR) Suitable for up to 35 kV commonmode.
140 dB CMRR.
High Voltage Differential Probes Low cost active differential probes are
WaveRunner
WaveMaster
intended for measuring higher voltages.
WaveSurfer
LabMaster
WavePro
WaveJet
The differential techniques employed
HDO
permit measurements to be taken at two
HVD3102A 25 MHz High Voltage Differential Probe, nnnnn points in a circuit without reference to
1,500 Vp-p Differential Voltage Range the ground, allowing the oscilloscope to
HVD3106A 120 MHz High Voltage Differential Probe, nnnnn be safely grounded without the use of
1,500 Vp-p Differential Voltage Range opto-isolators or isolating transformers.
HVD3106A-6M 80 MHz High Voltage Differential Probe, nnnnn
1,500 Vp-p Differential Voltage Range,
6 m cable
HVD3206A 2 kV, 120 MHz High Voltage Differential Probe nnnnn
HVD3605A 6 kV, 100 MHz High Voltage Differential Probe nnnnn
High Voltage Passive Probes The High Voltage Passive Probes product
WaveRunner
WaveMaster
WaveSurfer
LabMaster
WaveMaster
WaveSurfer
WaveMaster
WaveSurfer
Probe Adapters
WaveRunner
WaveMaster
WaveSurfer
LabMaster
WavePro
WaveJet
HDO
21
MODULAR INSTRUMENTS
Overview peak rates of up to 6.8 Gbyte/s. heavy applications where the digitizer is
This offers a great complement to the used in conjunction with a GPU.
Our extensive product portfolio enable
offered open FPGA architecture.
cost-optimized system-level solutions PXIe boards are intended for
and the modular approach allows for integration into a chassis for modular
compact yet scalable systems that can instrumentation. This type of system
easily be tailored for specific needs. is suitable for multi-channel data
acquisition and offer synchronization
The modules offer flexible operation by
capabilities as well as mechanical
supporting AC- or DC-coupling, adjust-
robustness.
able DC-offset, programmable input
voltage range, advanced triggering, and MTCA.4 boards are typically used for
choice of single-ended or differential multi-channel applications with high
outputs1). This helps simplify integra- Peer-to-peer streaming to GPU. channel count. The boards are also
tion trough good matching with most equipped with Ethernet which allows for
sensors. operation via long-distance fiber and
System-Level Features
high precision synchronization via
Signal Processing Capabilities In addition to the versatile analog White Rabbit.
All data acquisition and signal functions the modules also include
USB boards offer compact stand-
generation modules host powerful field- other features that help simplify
alone operation and can easily be
programmable gate arrays (FPGAs) integration.
integrated into existing designs. Analog
which are made available to the user The wide range of available form factors performance can also be optimized
through optional firmware development offers great flexibility in choosing the by placing the digitizer close to the
kits. This allows for custom real-time most suitable solution for any specific detector so that cables can be kept
signal processing to be performed system. short to ensure good signal quality. Data
on the raw data stream – a crucial streaming can be done at high rates
PCIe boards are typically integrated into
requirement for many of today’s and combined with data reduction in the
standard stationary PCs or in compact
systems. There are also additional open FPGA if required.
embedded solutions. This is especially
stand-alone firmware packages which
useful for applications which require A wide range for form factors helps
simplify operation by providing rich sets
high throughput and computationally simplify integration.
of application-specific functions without
any need for firmware development.
1)
Depending on product model.
22
Learn More: www.spdevices.com
Selected Products
Below is a list of selected product models from SP Devices.
For a full list of products and more please visit our website at www.spdevices.com.
23
PROTOCOL ANALYZERS Learn More: teledynelecroy.com/protocolanalyzer
teledynelecroy.com
© 2018 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice.
Product or brand names are trademarks or requested trademarks of their respective holders.
PCI Express® is a registered trademark and/or service mark of PCISIG. PLC-05-2018