2800 Series synchronization without the aid of Perkins electronic tooling
Machine Wiring Schematic, All Options
This Wiring Supplied By OEM Customer Interface Crank Terminate ECM Notes: (Engine Running J3 P3 Connector Signal) Outputs may be used to T 11 J1/13 Crank Terminate Output drive lamps or relays. C K Crank Terminate should be a relay used to disconnect Shutdown the starter motor in OEM panel start circuit. (ECM latched out) 16 J1/10 Shutdown lamp Output G Diagnostic lamp lights when active system fault Action Alert registered Action Alert Lamp Output 5 J1/19 For full details of inputs/ U outputs, refer to Installation Manual Warning 4 J1/20 Warning Lamp Output P Diagnostics 3 J1/31 Diagnostics Lamp Output K Low Oil Pressure 8 J1/28 Oil Pressure Lamp Output O High Coolant Temp 17 J1/29 Coolant Temperature Lamp Output N Overspeed 9 J1/30 Overspeed Lamp Output A Off - Disabled - Stop 34 J1/62 Injection Disable Injection Disable On - Enabled - Run U On 35 J1/64 Shutdown Emergency Override Critical Override Off K (Disables Oil & Water shutdowns when on) O 1500 25 J1/56 1500/1800 rpm Select 1500/1800 1800 N rpm Select Isoch 26 J1/46 Droop/Isochronous Droop/ Droop A Isochronous On the OEM machine 18 J1/41 Fault Reset Fault Reset interface wiring, make Enable 2 J1/49 Digital Speed Control Enable a link wire between Digital Speed Control Disable G PIN 2 and PIN 12 Digital Speed 29 J1/59 Lower Speed Control Lower Speed P
28 Y J1/7 Raise Speed
If you are using a Raise Speed 12 J1/18 Digital Ground 5k ohm 27 B J1/67 Unswitched Battery Negative B potentiometer for Ground 22 B J1/5 Ground PWM Speed synchronization Control PWM 36 W J1/66 PWM Input +8V 21 J1/4 +8V the following PINS R 23 are used: 680R B 5K Analogue 20 J1/3 Analogue Ground PIN 20, PIN 24, & Speed Setting B Potentiometer or 24 J1/17 Analogue Speed Input PIN 19 Input from Load W Sharer/Synchroniser 19 J1/2 +5V 680R R 38 J1/61 Unswitched Battery Negative B If you are using a Charging Alternator 39 J1/63 Unswitched Battery Negative Main B digital speed GRD POS 40 J1/65 Unswitched Battery Negative Battery Feed Emergency B controller, then Stop Button 15 J1/48 Unswitched Battery Positive (Direct from R you only need to 33 J1/52 Unswitched Battery Positive starter/ battery) R connect to PIN 24 1 J1/53 Unswitched Battery Positive R Analogue Speed Off 10 J1/70 Switched Battery Positive Y Input and Circuit Key On Switch 31 J1/50 J1939 Data Link + possibly PIN 20 Breaker J1939 Y (16A) Data 32 J1/34 J1939 Data Link - Analogue Link G J1/42 J1939 Screen Ground Starter Perkins 7 J1/8 Perkins Data Link + G depending on Motor Data 6 J1/9 Perkins Data Link - Start Link N your interface Button R J1/55 Unswitched Battery Positive Power device J1/69 Unswitched Battery Negative Supply to Service B Tool - + P1 J1 Battery 9 Pin Perkins Data 24V DC J H C G F D E A B Link Connector