Sunteți pe pagina 1din 4

Seismic Parameter

http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/

Soil Category C Hard Soil


PGA (g) 0.355
SS (g) 0.696
S1 (g) 0.282
CRS 0.991
CR1 0.907
FPGA 1.045
FA 1.122
FV 1.518
PSA (g) 0.371
SMS (g) 0.781
SM1 (g) 0.428
SDS (g) 0.52
SD1 (g) 0.285
T0 (detik) 0.11
TS (detik) 0.548

SNI-1726-2012
Value
Seismic Parameter Type SS Type CS Type EF1 Type EF2 Remarks
Soil Category C 客指定

Important factor I = 1.50 1.50 1.50 1.50 客指定

Response modification factor R 3.50 3.00 1.50 3.00 Depends on equipment and structure. To follow related spec/CODE like ASCE 7-10, API, etc.
S1 [g] 0.282 0.282 0.282 0.282 http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/
Ss [g] 0.696 0.696 0.696 0.696 http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/
Fa 1.122 1.122 1.122 1.122 http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/
Fv [s] 1.518 1.518 1.518 1.518 http://puskim.pu.go.id/Aplikasi/desain_spektra_indonesia_2011/
Sm1 [g] 0.428 0.428 0.428 0.428 Sm1 = S1*Fv
Sms [g] 0.781 0.781 0.781 0.781 Sms = Ss*Fa
Ts [s] 0.55 0.55 0.55 0.55 Ts = SD1 / SDS
T0 [s] 0.11 0.11 0.11 0.11 T0 = 0.2SD1 / SDS
TL [s] Location where Sd(TL) = 0.01
Damping coefficient [%] 5.00 5.00 5.00 5.00

Seismic Design
Sds 0.521 0.521 0.521 0.521 Sds = 2/3 Sms
Sd1 0.285 0.285 0.285 0.285 Sd1 = 2/3 Sm1
Horizontal force coefficient Cs 0.223 0.260 0.521 0.260 Cs = Sds / (R/I)

0.060 0.071 0.141 0.071 Csmin = 0.5*S1/(R/I), for str located where S1 => 0.6g
Csmin
0.034 0.034 0.034 0.034 Csmin = 0.044*SDS*I >= 0.01
Check OK OK OK OK

Note
Type SS For Steel Structure Building
Type CS For Concrete Structure Building
Type EF1 For Special Equipment Foundation
Type EF2 For Simple Equipment Foundation
11 11
11 11
11 11
11
11 11
11 11
11 11
11
11 11
11
11
11
11 11
11
11 11
11
11 11
11 11 11
11 11 11
11 11 11
11 11 11
11 11
11 11 11
11 11 11
11 11 11
11 11 11
11 11 11
11 11
11 11 11
11 11
11 11 11 11
11 11
11 11 11
11 11
11
11 11
11 11
11
11 11
11
11
11
11
- Volume of Steel Structure = 49,426 m3
- MTO Steel Structure in STAAD = 842,732 kg
- Required MTO Steel Structure = 1,285,076 kg ; Based on Civil WV Data base for proposal work, weight of steel shall be 26-35 kg/m 3 volume of enclosed building