Some Pile Load Test Experience on Grouted and Non-grouted Piles in Bangladesh.
Method of Pile length Ult./Design capacity Test load on Pile
SL. No. Pile Type Location Pile Dia Comments
construction from EGL of Pile (kN)
125% of design load is applied. Gross and
Bored cast in situ RCC
9248 kN
1 (grouted), RCD Padma multi purpose bridge 1.2m 75m 11560kN net settlement 11.54mm and 8.56mm
(Design Capacity)
[Service Pile]
respectively has been recorded.
Bored cast in situ RCC City Group Ltd. 124.76% of ultimate capacity has been
4 DMC 0.85m 41m 6300kN 7860kN
(grouted) Narayanganj. achieved.
NOTE:
DMC: DIRECT MUD CIRCULATION METHOD OF PILING.