AIR-CONDITIONING & REFRIGERATION EXPERIMENTAL EQIUPMENT

Jakarta, t: +62 21 385-6636 e: jakarta@grahaelektrotama.com | Surabaya, t: +62 31 534-8071 e: surabaya@grahaelektrotama.com

NO. EQUIPMENT NAME MODEL structure must be mixed.)


2. The indoor air conditioning and automatic control equipment, the
PT. Graha Elektro Tama

Lab-View control Air Handling Unit


02 KTE-2000AHU structure of education should be, and to observe the internal duct and
Experimental Equipment
the air and adjust the air volume of the bet with the initial suction
I. IMAGE temperature.
3. Air conditioning and automatic control of training equipment to the cooler
and heater by water type of a water tank with temperature control.
4. Air conditioning and automatic control of education by using the
equipment, ultrasonic humidifier, and humidification control is to be made
available to the structure.
5. Air conditioning and automatic control, training equipment, both the open
display of the damper and adjust the ratio of indoor and outdoor is the
structure.

IV. SPECIFICATION

1. Machine device
(1) Air blower
1) Power : 24DCV, 1A, Size : 225mm × 236mm
 Appearance and specifications may be changed by the upgrade.
2) Airflow: 24 ㎥/hr, 804CFM, Weight: 2.5Kg
II. FEATURE 3) Noise : 76dB(A), Impeller : Nylon 66+30%Fiber
4) Housing : Nylon 66+30%PVC
1. Study for the principle of air-conditioning in construct field. (2) Air duct at Inlet
2. Experiment cooling and heating with control of intake, exhaust and return (3) Air duct at Exhaust
air. (4) Damper 1, 2: Operated by 4step type with Rack
3. Measurement performance of individual device in mechanical air- (5) Damper 3: Operated by 3step type with Rack
conditioning. (6) Chamber
4. Control Air-conditioning with electric penal or computing programming (7) Pump : AC 220V 60Hz, 55W, Magnet Pump
software. (8) Water Tank
5. Measurement performance of refrigeration system. (9) Constant temperature tank: Cool water
6. Obtaining data and control the system with NI DAQ equipment. 1) SUS304 Thickness 2t
7. Experiment with computing programming of NI LabView. 2) 15A x 15A Elbow : 6EA, 15A Ball Valve : 2EA
8. Drawing psychometric chart and analysis with real time. 3) Baffle : SUS304, L270× W280x Thickness 2t
4) Heat exchanger: Fin-Tube Type L165× W180 × H65 ㎜, 1/2HP

KTE-2000AHU
KTENG
III. Description (10) Constant thermal water tank : Hot water
1. New air conditioning and automatic control, training equipment, the 1) SUS304 Thickness 2t
configuration of the cycle, the outside air→ mixed air → filter 1 → 2) 15A x 15A Elbow : 6EA, 15A Ball Valve : 2EA
cooler → dehumidifier → heater → filter 2 → ventilation blower → 3) Baffle : SUS304, L270× W280x Thickness 2t,
humidifier → Indoor → exhausting air should be composed. 4) Heater : 1kW X 3EA
(However, the air volume control, and indoor and outdoor air, as the

KTENG CORPORATION | 2013

5
AIR-CONDITIONING & REFRIGERATION EXPERIMENTAL EQIUPMENT
Jakarta, t: +62 21 385-6636 e: jakarta@grahaelektrotama.com | Surabaya, t: +62 31 534-8071 e: surabaya@grahaelektrotama.com

(11) Stop V/V for drain (6) Differential pressure sensor: 4~20mA, Measurement Range:
(12) Nozzle : 30φ, 250mm, spray type 0~50…1000Pa, Precision 0.3...1%FS
PT. Graha Elektro Tama

(13) Compressor : 1.5HP, for R-22, single 220V, Include Control Box
(14) Condenser and fan motor : 1.5HP, Air cooling, single 220V, 60Hz, 3. NI Constant thermal water tank : Hot water DAQ Instruments
66W (1) NI cDAQ 9172 Chassis (8 Modules)
(15) Nipple: 2EA at each of high and low pressure (2) NI 9205 32-Ch ±200 mV to ±10 V, 16-Bit, 250 kS/s Analog Input
(16) Expansion V/V: Manual type, Range(1/2~3/2 tons), Module, 2ea
Temperature0℉ (-10℃) (3) NI 9211 4-Channel, 14 S/s, 24-Bit, ±80 mV Thermocouple Input
(17) Solenoid V/V: ⅜″ Welding type Module
(18) Filter dryer: ⅜″Welding type (4) NI 9472
(19) Pressure gages: 1EA each of high and low pressure, oil type (5) NI 9901 Desktop Mounting kit
(20) Sight glass : Welding type
(21) Filter 1, Filter 2 : Fabric 4. Control panel specification
(22) Receiver: Cylinder type, Include a Service V/V (1) S/S.W, TOGGLE, BUZZER, PUSH S.W MODULE
1) 3/4 Hp, 22kgf/cm2G, Pressure test(33kgf/cm2G) 1) Select Switch (3 step, 2a)
2) Leak pressure(22kgf/cm2G), Down to 75℃, 90φ, 190mm, 265mm, 2) Toggle Switch
140mm 3) DC Lamp (DC24V)
(23) Accumulator: 1HP, single intake, VERTICAL TYPE (2) THERMO METER MODULE
(24) Chiller (Heat exchanger): Fin-Tube Type, 1/2HP, Passing water type 1) Electronic Digital Relative Humidity controller (AC/DC 12~15V, 0
(25) Dehumidifier (Heat exchanger) : Fin-Tube Type 1/2HP, Passing ~100%)
refrigerant type 2) Electronic Digital Temperature Meter (220V AC50 ~ 60Hz, -40.0 ~
(26) Heater (Heat exchanger) : Fin-Tube Type 1/2HP, Passing water type 100℃)
(27) Humidifier : Ultrasonic Humidifier (Humidify volume control ) 3) Electronic Digital Temperature controller (AC/DC 12~15V, Heating
or cooling, -40.0 ~ 100℃)
2. Sensor (3) POWER MODULE
(1) Humidity meter : Power : 12V/DC, Detecting range : 20 ~ 90% RH 1) S.M.P.S (24V 3.1A) : 1EA
1) Output range : 4 ~ 20mA, Sensor type : Resistance, Accuracy <± 2) S.M.P.S (5V 3.1A) : 1EA
3% 3) N.F.B (15A, Single) : 1EA
(2) Relative humidity sensor 4) VOLT METER (AC 220V Full scale) : 1EA
1) Measurement of Polymer Sensors ± 5%, Measurement Range: RH 5) AM METER (AC 20A Full scale) : 1EA
30 ~ 50%, Input : DC 5V , Output : 0 ~ 3.3v 6) Magnet Contact (DC24V), 13A, 5a, 2b : 2EA
(3) CO2 Sensor : NDIR, Measurement of ±30ppm ±3%, 7) Relay (DC24V, 8Pin) : 8EA
1) Measurement Range: 0~2000ppm, 8) Relay Base : 8EA
2) Input: 4.5 ~ 14 VDC, Output: 1 ~ 4 VDC 9) Fan Speed Controller :2EA

KTE-2000AHU
KTENG
(4) Pressure sensor: Difference pressure trans meter for small air 10) Terminal : 3EA
conditioning unit (Differential pressure measurement type), digit bar
graph LCD display V. Data Acquisition and Post-Processing by Lab-View Program
1) Measurement Range: 0~50Pa, Input: 11 ~ 28 VDC, Precision:
0.3...1%FS, 1. Function
2) Output: 4~20mA (2Wire) (1) Auto operation, manual operation, and measurement of flowing air
(5) Thermometer: 5φ, 170mm, T-type Thermocouple volume with measuring device.
KTENG CORPORATION | 2013

5
AIR-CONDITIONING & REFRIGERATION EXPERIMENTAL EQIUPMENT
Jakarta, t: +62 21 385-6636 e: jakarta@grahaelektrotama.com | Surabaya, t: +62 31 534-8071 e: surabaya@grahaelektrotama.com

(2) Measurement of air properties at atmosphere pressure. VI. ACCESSORIES, GUARANTEE AND DELIVERY
(3) Display of Co2 volume in Chamber
PT. Graha Elektro Tama

(4) Display through Indicator for start and running time


1. Power connection Cable: 1 EA
(5) Leading real-time data Psy diagram are represented in the
2. Banana Jack: Red 20EA, Black 20EA
experiment, the normal state is reached output or save the picture
3. Manual book: 1EA
file.
4. DA200 Software: 1EA
(6) Each location in the system of the dry air temperature, saturation
5. Delivery: 3 Month
pressure, relative humidity, absolute humidity, and enthalpy must be
6. Guarantee: For 1 year
known.
(7) Representation of data in accordance with the Sampling Rate on
your computer, save the Excel file
(8) Experimental for cooling, cooling with dehumidify, dehumidify,
heating, humidify, and amount of electric heating at each process.
(9) Manual operation: Available experiment with any cycle what student
chooses.

2. Composition: Main Page, Sector for display of temperature and humidity


data, for graph chart of temperature and humidity data, for manual
operation control, for pressure graph of compressor, for calculation
cooling volume, cooling dehumidify volume, dehumidify volume, heating
volume, and humidify volume.