5 SP1 Hotfix 5
With Hotfix 5 to STARTER V4.5 SP1, the following restriction of SP1 is eliminated.
SINAMICS DCM
Once activated, write protection can no longer be deactivated. (TFS 503164)
Once activated, know-how protection can no longer be deactivated. (TFS 498347)
The write and know-how protection functions are enabled as from Hotfix 5 for SINAMICS DCM.
SINAMICS DCP
Know-how protection was not able to be used fully for SINAMICS DCP. Hotfix 5 remedies this
situation and ensures that this function cannot be selected in DCP.(TFS 477609)
SINAMICS V4.5 SP1 and SINAMICS S120; configuration with double motor modules
Problem with the reassignment of Xy interfaces that have become free with double motor
modules; the free interface is not offered in the STARTER (TFS 560379).
STARTER V4.5 SP1 with devices SINAMICS G120 V4.7 SP6 and Ethernet/IP mode
(p2030=10)
If this communication mode is set in the G120 device, then the devices are not identified by the
function "Accessible nodes" via Ethernet. (TFS 554786).
Configuration of SINAMICS G120 drive unit with free telegram in combination with a
PROFIsafe telegram (30 or 900)
A compile error can be generated with STARTER V4.5 SP1 with such telegram combinations
(also for converted projects).
The HF5 corrects this error and STARTER V4.5 SP1 HF5 thus behaves in an identical manner to
STARTER V4.4 SP1. (TFS 536867)