Solved problems with STARTER V4.

5 SP1 Hotfix 5

With Hotfix 5 to STARTER V4.5 SP1, the following restriction of SP1 is eliminated.

SINAMICS DCM
Once activated, write protection can no longer be deactivated. (TFS 503164)
Once activated, know-how protection can no longer be deactivated. (TFS 498347)
The write and know-how protection functions are enabled as from Hotfix 5 for SINAMICS DCM.

SINAMICS DCP
Know-how protection was not able to be used fully for SINAMICS DCP. Hotfix 5 remedies this
situation and ensures that this function cannot be selected in DCP.(TFS 477609)

SINUMERIK NCUs and STARTER V4.5 SP1


Software versions 4.5 and 4.7 of STARTER V4.5 SP1 do not allow access to SINUMERIK NCU
online. Although nodes are found via the search for accessible nodes, they are not recognized.
(TFS 519029)

F-systems and Standard SIMATIC STEP 7 V5.x


Use of F-systems in the Standard SIMATIC STEP 7 V5.5 SPx environment:
SINAMICS S120, S150, G130, and G150 firmware version V4.8 is now supported by the XML
file.

Patch for security vulnerability


The setup of Hotfix 5 for STARTER V4.5 SP1 patches a security vulnerability (TFS 529646) in
SIMATIC STEP 7 V5.x.
(see link http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-701708.pdf

STARTER V4.5 SP1 together with SSP SINAMICS MV V4.8 SP2


Assurance of the availability of the OA parameters (TFS 545363).

SINAMICS V4.5 SP1 and SINAMICS S120; configuration with double motor modules
Problem with the reassignment of Xy interfaces that have become free with double motor
modules; the free interface is not offered in the STARTER (TFS 560379).

STARTER V4.5 SP1 and SINAMICS DCC


There are DCC input parameters in the expert list. If a DCC input parameter is first
interconnected with a SINAMICS basic parameter, and then the DCC input parameter is set to
the value 100%, this results in the following malfunction:
- The view jumps to the start of the expert list
- All DCC parameters are no longer displayed in the expert list.
(TFS 470388).

STARTER V4.5 SP1 and SINAMICS DCC


The expert list no longer shows the DCC specific parameters after the STARTER functions "Load
into the device" or "Load into the PC/PG". The expert list has to be closed and reopened. (TFS
384391).

Unrestricted copyright SIEMENS AG 2017. All rights Reserved Page of


Solved problems with STARTER V4.5 SP1 Hotfix 5

STARTER V4.5 SP1 with devices SINAMICS G120 V4.7 SP6 and Ethernet/IP mode
(p2030=10)
If this communication mode is set in the G120 device, then the devices are not identified by the
function "Accessible nodes" via Ethernet. (TFS 554786).

Configuration of SINAMICS G120 drive unit with free telegram in combination with a
PROFIsafe telegram (30 or 900)
A compile error can be generated with STARTER V4.5 SP1 with such telegram combinations
(also for converted projects).
The HF5 corrects this error and STARTER V4.5 SP1 HF5 thus behaves in an identical manner to
STARTER V4.4 SP1. (TFS 536867)