Documente Academic
Documente Profesional
Documente Cultură
RUGGEDCOM RS900
9-port Managed Ethernet Switch With Fiber Optical Uplinks,
128-bit Encryption
The RUGGEDCOM RS900 from Siemens is a 9-port The embedded Rugged Operating System (ROS) provides
utility grade, fully managed, Ethernet switch specifically advanced cyber security features and comprehensive
designed to operate reliably in electrically harsh and networking functions such as Enhanced Rapid Spanning Tree
climatically demanding environments. (eRSTP), Port Rate Limiting, and a full array of intelligent
functionality for high network availability and manageability.
Designed to operate reliably in harsh environments, the Coupled with ruggedness and durability that is designed
RS900 provides a high level of immunity to electromagnetic in from the onset, the RS900 is ideal for creating mission
interference and heavy electrical surges typical of critical, real-time, control applications where high reliability
environments found in electric utility substations, curb side and availability is of paramount importance.
traffic control cabinets, and factory floors. An operating
temperature range of -40°C to +85°C coupled with All RUGGEDCOM products are backed by a five year warranty
hazardous location compliance, optional conformal and unsurpassed technical support.
coating and a galvanized steel enclosure allows the RS900
to be placed in almost any location.
usa.siemens.com/ruggedcom
Features and Benefits
Ethernet Ports Rugged Operating System (ROS) Features
■ Up to 9 Ports: 6 Base 10/100BaseTX ports with option ■ Simple plug and play operation – automatic learning,
for 3 additional fiber or copper ports negotiation, and crossover detection
■ Industry standard fiber optical connectors: ■ MSTP 802.1Q-2005 (formerly 802.1s)
■ LC, SC, ST, MTRJ ■ RSTP (802.1w) and Enhanced Rapid Spanning Tree
■ Multimode and Singlemode optical transceivers (eRSTP) network fault recovery (<5ms)
■ Long haul optics allow distances up to 90km ■ Quality of Service (802.1p) for real-time traffic
■ VLAN (802.1Q) with double tagging and GVRP support
Cyber Security Features ■ Link aggregation (802.3ad)
■ Multi-level user passwords ■ IGMP snooping for multicast filtering
■ SSH/SSL/SFTP (128-bit encryption) ■ Port configuration, status, statistics, mirroring, security
■ Enable/disable ports, MAC based port security ■ Industrial automation features (eg. Modbus)
■ Port based network access control (802.1x)
■ VLAN (802.1Q) to segregate and secure network traffic Management Tools
■ RADIUS centralized password management ■ Web-based, Telnet /SSH, CLI management interfaces
■ SNMPv3 authentication and 56-bit encryption ■ SNMP v1/v2/v3 (56-bit encryption)
■ Remote Monitoring (RMON)
Rugged Rated for Reliability in Harsh ■ Rich set of diagnostics with logging and alarms
Environments
■ Immunity to EMI and heavy electrical surges Universal Power Supply Options
- Meets IEEE 1613 class 1 (electric utility substations) ■ Fully integrated power supply (no external adaptors)
- Exceeds IEC 61850-3 (electric utility substations) ■ Popular low-voltage DC ranges: 24VDC (10-36VDC) or
- Exceeds IEC 61800-3 (variable speed drive systems) 48VDC (36-72VDC)
- Exceeds IEC 61000-6-2 (generic industrial) ■ Universal high-voltage range: 88-300VDC or 85-264VAC
- Exceeds NEMA TS-2 (traffic control equipment) ■ CSA/UL 60950 safety approved to +85°C
■ Hazardous Location Compliance: Class 1 Division 2 ■ Screw connection terminal blocks ensure reliable
■ -40°C to +85°C operating temperature (no fans) maintenance free connections
■ Conformal coated printed circuit boards (optional)
2 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
RUGGEDCOM RS900
Optional Ports Operating
Up to 3 Ports Temperature
Fast 10/100BaseTx -40°C to +85°C
Fiber optical (MMF/SMF) No fans
SC, ST, LC and MTRJ
Bi-directional (single strand)
Distances up to 90km
Rugged Construction
20 AWG galvanized
steel enclosure
Hazardous Location Conformal coating
Compliance (optional)
Class 1, Division 2
Integrated
Power Supply
Universal high-voltage
range:
88-300VDC or
85-264VAC
Fast Ethernet Ports Popular low voltage
6 - Fast Ethernet ports DC ranges:
(10/100BaseTX) 24VDC (10-36VDC)
48VDC (36-72VDC)
Dual Isolated DC
power inputs
9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption RUGGEDCOM RS900 3
ROS Features
Cyber Security Quality of Service (IEEE 802.1p)
Cyber security is an urgent issue in many industries where Some networking applications such as real-time control
advanced automation and communications networks play or VoIP (voice over IP) require predictable arrival times for
a crucial role in mission critical applications and where high Ethernet frames. Switches can introduce latency in times
reliability is of paramount importance. Key ROS features that of heavy network traffic due to the internal queues that
address security issues at the local area network buffer frames and then transmit on a first come first serve
level include: basis. ROS supports ‘Class of Service’ in accordance with
■ Passwords – Multi-level user passwords secures switch IEEE 802.1p that allows time critical traffic to jump ahead
against unauthorized configuration to the front of the queue thus minimizing latency and
■ SSH / SSL – Extends capability of password protection reducing jitter to allow such demanding applications to
to add 128-bit encryption of passwords and data as they operate correctly. ROS allows priority classification by
cross the network port, tags, MAC address, and IP type of service (ToS). A
configurable “weighted fair queuing” algorithm controls
■ Enable/Disable ports – Capability to disable ports so
how frames are emptied from the queues.
that traffic can not pass
■ 802.1Q VLAN – Provides the ability to logically segregate VLAN (IEEE 802.1Q)
traffic between predefined ports on switches Virtual local area networks (VLAN) allow the segregation
■ MAC based port security – The ability to secure ports of a physical network into separate logical networks with
on a switch so only specific Devices / MAC addresses independent broadcast domains. A measure of security is
can communicate via that port provided since hosts can only access other hosts on the
■ 802.1x Port based network access control – The ability same VLAN and traffic storms are isolated. ROS supports
to lock down ports on a switch so that only authorized 802.1Q tagged Ethernet frames and VLAN trunks. Port
clients can communicate via this port based classification allows legacy devices to be assigned to
■ RADIUS – authentication service using MD5 hash and the correct VLAN. GVRP support is also provided to simplify
providing centralized password management the configuration of the switches on the VLAN.
■ SNMPv3 – encrypted authentication access security and Link Aggregation (802.3ad)
data encryption (CBC-DES with 56-bit encryption key)
The link aggregation feature provides the ability to
■ Secure socket layer – Web-based management using aggregate several Ethernet ports into one logical link (port
SSL with data encryption (128-bit encryption key) trunk) with higher bandwidth. This provides an inexpensive
■ RSA – 1024 bit key for key management and key way to set up a high speed backbone to improve network
exchange bandwidth. This feature is also known as “port trunking,”
■ TACACS+ – Terminal Access Control and Accounting “port bundling,” “port teaming,” and “Ethernet trunk.”
Services. Client provides encrypted authentication
and authorization IGMP Snooping
■ Point to Point (PPP) – using CHAP (MD5 Hash) ROS uses IGMP snooping (Internet Group Management
authentication service Protocol v1&v2) to intelligently forward or filter multicast
■ SFTP – Secure File Transfer Protocol using SSH encryption traffic streams (e.g. MPEG video) to or from hosts on the
network. This reduces the load on network trunks and
The ROS cyber security features are included to help address prevents packets from being received on hosts that are
the various industry specific security standards such as not involved. ROS has a very powerful implementation
NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 of IGMP snooping that:
and PCSRF SPP-ICS. ■ Can be enabled on a per VLAN basis
■ Detects and filters all multicast streams regardless of
Enhanced Rapid Spanning Tree Protocol whether subscribers exist
(eRSTP)
■ Supports “router-less” operation by supporting an
RUGGEDCOM eRSTP allows the creation of fault-tolerant
“active” mode
ring and mesh Ethernet networks that incorporate
redundant links that are ‘pruned’ to prevent loops. eRSTP ■ Restores traffic streams immediately after an RSTP
yields worst-case fault recovery 1 of 5ms times the ‘bridge topology change
diameter’ and allows rings of up to 160 switches. For
example, a ring of ten switches will have fault recovery
times under 50ms. eRSTP implements both STP and
RSTP to ensure interoperability with commercial switches
unlike other proprietary ‘ring’ solutions.
1 eRSTP fault recovery times may be approximated as follows:
For 100 Mbps, fault recovery performance is <5ms/hop
For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms
4 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
ROS Features
SNMP (Simple Network Management Protocol) Loss of Link Management
SNMP provides a standardized method for network Some intelligent electronic devices (IEDs) have dual fiber
management stations to interrogate devices from different optic ports with automatic failover to a backup port should
vendors. SNMP versions supported by ROS are v1, v2c, and the primary fail. ROS ensures this mechanism works reliably
v3. SNMPv3, in particular, provides security features such as under all failure modes by appropriately disabling link signals
authentication, privacy with data encryption (CBC-DES with when required. ROS also flushes learned MAC addresses to
56-bit encryption key) and access control not present in ensure the failover occurs quickly.
earlier SNMP versions. ROS also supports numerous standard
MIBs (Management Information Base) allowing for easy Port Configuration and Status
integration with any network management system (NMS). ROS allows individual ports to be ‘hard’ configured for speed,
duplex, auto-negotiation, flow control and more. This allows
A feature of SNMP supported by ROS is the ability to proper connection with devices that do not negotiate or have
generate “traps” upon system events. RUGGEDCOM NMS, the unusual settings. Detailed status of ports with alarm and SNMP
RUGGEDCOM management solution, can record traps from trap on link problems aid greatly in system troubleshooting.
multiple devices providing a powerful network troubleshooting
tool. It also provides a graphical visualization of the network Port Statistics and RMON (Remote Monitoring)
and is fully integrated with all RUGGEDCOM products. ROS provides continuously updating statistics per port that
provide both ingress and egress packet and byte counters as
SNTP (Simple Network Time Protocol) well as detailed error figures. Also provided is full support
SNTP automatically synchronizes the internal clock of all for the RMON statistics, history, alarms, and event groups.
ROS devices on the network. This allows for correlation RMON allows for very sophisticated data collection, analysis
of time stamped events for troubleshooting. and detection of traffic patterns.
9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption RUGGEDCOM RS900 5
EMI and Environmental Type Tests
IEC 61850-3 EMI Type Tests
Test Description Test Levels Severity Levels
Enclosure contact +/- 8kV 4
IEC 61000-4-2 ESD
Enclosure air +/- 15kV 4
IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m Note 1
Signal ports +/- 4kV @ 2.5kHz Note 1
D.C. power ports +/- 4kV 4
IEC 61000-4-4 Burst (fast transient)
A.C. power ports +/- 4kV 4
Earth ground ports 3 +/- 4kV 4
Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4
IEC 61000-4-5 Surge D.C. power ports +/- 2kV line-to-earth, +/- 1kV line-to-line 3
A.C. power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4
Signal ports 10V 3
D.C power ports 10V 3
IEC 61000-4-6 Induced (conducted) RFI
A.C. power ports 10V 3
Earth ground ports 10V 3
40 A/m continuous, 1000 A/m for 1 s Note 1
IEC 61000-4-8 Magnetic field Enclosure ports 3
1000 A/m for 1 s 5
D.C. power ports 30% for 0.1s, 60% for 0.1s, 100% for 0.05s N/A
IEC 61000-4-29
Voltage dips and interrupts 30% for 1 period, 60% for 50 periods N/A
A.C. power ports
IEC 61000-4-11 100% for 5 periods, 100% for 50 periods N/A
Signal ports 2.5kV common, 1kV diff. mode@1MHz 3
IEC 61000-4-12 Damped oscillatory D.C. power ports 2.5kV common, 1kV diff. mode@1MHz 3
A.C. power ports 2.5kV common, 1kV diff. mode@1MHz 3
Signal ports 30V Continuous, 300V for 1s 4
IEC 61000-4-16 Mains frequency voltage
D.C. power ports 30V Continuous, 300V for 1s 4
IEC 61000-4-17 Ripple on D.C. power supply D.C. power ports 10% 3
Signal ports 2kVac (Fail-safe relay output) N/A
IEC 60255-5 Dielectric strength D.C. power ports 1.5V DC N/A
A.C. power ports 2kVac N/A
Signal ports 5kV (Fail-safe relay output) N/A
IEC 60255-5 H.V. impulse D.C. Power ports 5kV N/A
A.C. Power ports 5kV N/A
6 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
EMI and Environmental Type Tests
NEMA TS-2 Requirements
Test Description Levels Performance Criteria
Temperature: 89.0 VAC @ -34°C
TS-2 1998, Section 2, para 2.2.7.3
Low temperature/Low voltage
Temperature: 135.0VAC @ -34°C
TS-2 1998, Section 2, para 2.2.7.4 EUT continued to function properly
Low temperature/Low voltage
during and following all temperature
Temperature: 135.0VAC @ + 75°C and humidity testing.
TS-2 1998, Section 2, para 2.2.7.5
High temperature/High voltage
Temperature: 89.0VAC @ + 75°C
TS-2 1998, Section 2, para 2.2.7.6
High temperature/High voltage
9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption RUGGEDCOM RS900 7
Technical Specifications
Power Supply EMI Immunity and Environmental Compliance
■ Power consumption: 10W Max ■ IEC 61000-6-2 Industrial (Generic)
■ 24VDC: 10-36 VDC, 0.4A ■ IEC 61800-3 Industrial (Variable Speed Drive Systems)
■ 48VDC: 36-72 VDC, 0.2A ■ IEC 61850-3 Electric Utility Substations
■ Hi voltage AC/DC: 88-300VDC or 85-264VAC ■ IEEE 1613 Electric Utility Substations
■ NEMA TS 2 Traffic Control Equipment
Critical Alarm Relay ■ Hazardous Location Class 1, Division 2
■ Form-C failsafe contact relay:
1A@30VDC IEEE Compliance
■ 802.3-10BaseT
Physical Dimensions ■ 802.3u-100BaseTX, 100BaseFX
■ Height: 7.4” (188mm) ■ 802.3x-Flow Control
■ Width: 2.6” (66mm) ■ 802.3ad-Link Aggregation
■ Depth: 5.0” (127mm) ■ 802.1D-MAC Bridges
■ Weight: 1.22kg ■ 802.1D-Spanning Tree Protocol
■ Ingress protection: IP40 (1mm objects) ■ 802.1p-Class of Service
■ Enclosure: 20 AWG galvanized steel enclosure ■ 802.1Q-VLAN Tagging
■ Mounting: DIN rail or panel mounted ■ 802.1w-Rapid Spanning Tree Protocol
■ 802.1x-Port Based Network Access Control
Switch Properties
■ 802.1Q-2005 (formerly 802.1s) MSTP
■ Switching method: Store and forward
■ Switching latency: 8 us (100Mbps) IETF RFC Compliance
■ Switching bandwidth: 1.8 Gbps ■ RFC768-UDP
■ MAC addresses: 8192 ■ RFC783-TFTP
■ Priority queues: 4 ■ RFC791-IP
■ Frame buffer memory: 1 Mbit ■ RFC792-ICMP
■ Simultaneous VLANs: 255 ■ RFC793-TCP
■ VLAN ID range: 1 to 4094 ■ RFC826-ARP
■ IGMP multicast groups: 256 ■ RFC854-Telnet
■ Port rate limiting: 128kbps, 256, 512, 4, 8Mbps ■ RFC894-IP over Ethernet
■ No head of line blocking ■ RFC1112-IGMP v1
■ RFC1519-CIDR
Regulatory Approvals
■ RFC1541-DHCP (client)
■ ISO: Designed and manufactured using an ISO9001: ■ RFC2030-SNTP
2000 certified quality program ■ RFC2068-HTTP
■ CE marking ■ RFC2236-IGMP v2
■ Emissions: FCC Part 15 (Class A), EN55022 (CISPR22 Class A) ■ RFC2284-EAP
■ Safety: cCSAus (Compliant with CSA C22.2 No. 60950, ■ RFC2475-Differentiated Services
UL 60950, EN60950) ■ RFC2865-RADIUS
■ Laser eye safety (FDA/CDRH): Complies with 21 CFR ■ RFC3414-SNMPv3-USM
Chapter 1, Subchapter J ■ RFC3415-SNMPv3-VACM
Network Management IETF SNMP MIBS
■ HTTPS graphical web-based, SSL (128-bit encryption) ■ RFC1493-BRIDGE-MIB
■ SNMP v1, v2c, v3 (56-bit encryption) ■ RFC1907-SNMPv2-MIB
■ Telnet, VT100, SSH/SFTP (128-bit encryption) ■ RFC2012-TCP-MIB
■ Command Line Interface (CLI) ■ RFC2013-UDP-MIB
■ RSA key management (1024 bit key) ■ RFC2578-SNMPv2-SMI
■ Authentication and accounting - TACACS+ (encrypted), ■ RFC2579-SNMPv2-TC
RADIUS client, PPP ■ RFC2819-RMON-MIB
■ RFC2863-IF-MIB
Warranty
■ draft-ietf-bridge-rstpmib-03-BRIDGE-MIB
■ 5 Years – Applicable to design and manufacturing related
■ draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB
product defects
■ IANAifType-MIB
8 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
Fiber Specifications and Dimension Drawings
RUGGEDCOM RS900 Chapter 5
Installation Guide
Fiber Optical Specifications Dimension Drawings
Parameter Fiber Port Type
Mode Multimode Singlemode
Dimension Drawings
Connector MTRJ, ST, SC, LC LC, SC, ST
Typical dist. (km) 2 20 50 90
Optical wavelength (nm) 1300 1310
Cable size core/xladding (um) 50/125 or 62.5/125 8 /125 or 9/125
TX power (dBm) -15.7 -15.5 -2.5 2.5
NOTE
RX sensitivity (dBm) -33.5 -32 -37 -39
All dimensions
Typical budget (dB) are in millimeters,
17 unless otherwise
16.5 stated. 34.5 41.5
65.126 116.586
168.656
187.960
2.540
99.060
9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption RUGGEDCOM RS900 9
21
Chapter 5 RUGGEDCOM RS900
Dimension Drawings Installation Guide
Dimension Drawings
183.896
194.056
83.820
78.740 120.650
22
10 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
Order Code
9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption RUGGEDCOM RS900 11
Example Order Codes
6GK6090-0AS21-0BA0-Z A01+B00
24VDC Power Supply, DIN Rail Mount, 2 10/100 TX Ports
6GK6090-0AS22-0CA1-Z A01+B04
48VDC Power Supply, Panel Mount, Conformal Coating,
2 10/100 TX Ports, 1 100FX ST MM
6GK6090-0AS23-0BA1-Z A00+B10
87-264VAC OR 88-300VDC Power Supply, DIN Rail Mount,
Conformal Coating, 1 100FX SC SM 20km
6GK6090-0AS23-0BA0-Z A17+B00
87-264VAC OR 88-300VDC Power Supply, 2 100FX LC SM 20km
6GK6090-0AS23-0AA1-Z A29+B12
87-264VAC OR 88-300VDC Power Supply, Conformal Coating,
2 100FX SC SM 50km, 1 100FX SC SM 90km
12 RUGGEDCOM RS900 9-port Managed Ethernet Switch With Fiber Optical Uplinks, 128-bit Encryption
Siemens Industry, Inc. Subject to change without prior notice. The information provided in this brochure contains descriptions or
5300 Triangle Parkway All rights reserved. characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of
Norcross, GA 30092 ©2015 Siemens Industry, Inc.
further development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in
1-800-241-4453 the terms of contract. Availability and technical specifications are
info.us@siemens.com subject to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.
usa.siemens.com/ruggedcom