Sunteți pe pagina 1din 28

RE 91001/01.

97

Fixed Displacement Motor A2FM RE


Series 6, for use in open and closed circuits
Axial tapered piston - bent axis design
91001/01.97
replaces 11.95
Brueninghaus Hydromatik Sizes 5...1000 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar

The fixed displacement motor A2FM of axial piston, bent


axis design is made suitable for hydrostatic drives in open
and closed circuits.

Output speed is proportional to input flow and inversely


proportional to displacement. Drive torque increases with
the pressure drop across the unit.

The motor is suitable for use in mobile and industrial


applications.

Careful selection of the displacements offered, permit sizes


to be matched to practically every application.

– Favourable power / weight ratio

– Compact and economic design

– Optimum efficiency

– One piece pistons with piston rings

– Patented cylinder block drive system

Brueninghaus Hydromatik 1/28


RE 91001/01.97

Fixed Displacement Motor A2FM

Ordering Code / Standard Program


(Ordering code size 5 see page 8)

Hydraulic fluid
Mineral oil (no code)
HF-fluids sizes 10...200 (no code)
sizes 250...1000 (only in connection with drive shaft bearings "L") E-

Axial piston unit


Bent axis design, fixed displacement A2F

Drive shaft bearings 10...200 250...500 710...1000


Mechanical bearings (no code) —
Long-Life bearings — L

Mode of operation
Motor (Plug-in motor A2FE see RE 91008) M

Size
Displacement Vg (cm3)
5 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Sizes 5...200: production plant Elchingen; Sizes 250...1000: production plant Horb
Series
6

Index
sizes 10...180 1
size 200 3
sizes 250...1000 0

Direction of rotation
viewed on shaft end alternating W

Seals 10...200 250...1000


NBR (nitril-caoutchouc) — P
NBR (nitril-caoutchouc), shaft seal in FPM — N
FPM (fluor-caoutchouc) V

Shaft end 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Splined shaft — — — — — A
DIN 5480 — — — — — — — Z
Parallel shaft with — — — — — — B
key, DIN 6885 — — — — — — — P

Mounting flange 10...250 355...1000


ISO 4-hole — B
ISO 8-hole — H

= available
− = not available

= preferred program
(preferred types see page 22)

2/28 Brueninghaus Hydromatik


RE 91001/01.97

Fixed Displacement Motor A2FM

A2F M / 6 W -
Hydraulic fluid

Axial piston unit

Drive shaft bearings

Mode of operation

Size

Series

Index

Direction of rotation

Seals

Shaft end

Mounting flange

Service line connections 1 ) 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 200 250 355 500 710 1000
Ports A and B 01 0 — — — 010
SAE, at rear end 6 — — — — — — — — — — — — — 016
Ports A and B SAE 02 0 — — — — — — — — 020
at side, opposite side 6 — — — — — — — — — — — — — 026
7 — — — — — — — — — — — 027
Ports A and B 03 0 — — — — — — — — — — — — — — — 030
threads, at side, opposite side
6 — — — — — — — — — — — — — — — — — — 036
Ports A and B 04 0 — — — — — — — — — — — — 040
threads, at side and rear end 6 — — — — — — — — — — — — — — — 046
Ports A and B SAE 10 0 — — — — — — — — — — 100
at side, same side 6 — — — — — — — — — — — — — — 106
port plate with integrated 19 1 — — — — — — — — — — 191
pressure relief valves 2 — — — — — — — — — — 192

Valves
without valves (no code) 0
with pressure relief valves (without pressure sequence range) 1
with pressure relief valves (with pressure sequence range) 2
with integrated flushing valve 6
with built-on flushing and boost valve 7

Speed sensing control 10...16 23...180 200...1000


without speed sensing control (no code)
prepared for speed sensing control — — D
1
) Threads of fixing screws and service lines are metric

Brueninghaus Hydromatik 3/28


RE 91001/11.95

Fixed Displacement Motor A2FM

Technical Data
Fluid Notes on the selection of the hydraulic fluid
We request that before starting a project detailed information about In order to select the correct fluid, it is necessary to know the
the choice of pressure fluids and application conditions are taken operating temperature in the loop (closed circuit) or the tank
from out catalogue sheets RE 90220 (mineral oil), RE 90221 temperature (open circuit) in relation to the ambient temperature.
(environmentally acceptable hydraulic fluids) and RE 90223 (fire The hydraulic fluid should be selected so that within the
resistance fluids, HF). operating temperature range, the operating viscosity lies within
When using HF- or environmentally acceptable hydraulic fluids the optimum range (ν opt) (see shaded section of the selection
possible limitations for the technical data have to be taken into diagram). We recommend that the highest possible viscosity
consideration. If necessary please consult our technical range should be chosen in each case.
department (please indicate type of the hydraulic fluid used for your Example: At an ambient temperature of X°C the operating
application on the order sheet). temperature (closed circuit: loop temperature; open circuit: tank
temperature) is 60°C. Within the operating viscosity range (ν opt;
Operating viscosity range shaded area), this corresponds to viscosity ranges VG 46 or VG
In order to optain optimum efficiency and service life, we 68. VG 68 should be selected.
recommend that the operating viscosity (at operating Important: The leakage oil (case drain oil) temperature is
temperature) be selected from within the range: influenced by pressure and motor speed and is always higher
νopt = operating viscosity 16...36 mm2/s than the circuit or tank temperature. However, at no point in the
circuit may the temperature exceed 115°C for sizes 5…200 or
referred to the loop temperature (closed circuit) or tank 90°C for sizes 250…1000.
temperature (open circuit). If it is not possible to comply with the above conditions because
of extreme operating parameters or high ambient temperatures
Viscosity limits please consult us.
The limiting values for viscosity are as follows:
sizes 5...200 Filtration
The finer the filtration the better the achieved purity grade of the
νmin = 5 mm2/s,
short term at a max. permissible temperature of tmax = 115°C pressure fluid and the longer the life of the axial piston unit.
To ensure the functioning of the axial piston unit a minimum
νmax = 1600 mm2/s, short term on cold start (tmin = -40°C)
purity grade of:
sizes 250…1000 9 to NAS 1638
νmin = 10 mm2/s 6 to SAE
short term at a max. permissible leakage oil temp. of tmax = 90°C 18/15 to ISO/DIS 4406 is necessary.
νmax = 1000 mm2/s,
At very high temperatures of the hydraulic fluid (90°C to max.
short term on cold start (tmin = -25°C)
115°C, not permissible for sizes 250…1000!) at least cleanless class
Please note that the max. fluid temperature is also not exceeded in 8 to NAS 1638
certain areas (for instance bearing area). 5 to SAE
17/14 to ISO/DIS 4406 is necessary.
At temperatures of -25°C up to -40°C special measures may be
required for certain installation positions. Please contact us for If above mentioned grades cannot be maintained please
further information. consult supplier.

Selection diagram Direction of Flow


Clockwise rotation Anti-clockwise rotation
2500-40° -20° 0° 20° 40° 60° 80° 100°
A to B B to A
1600 1600
1000
600 Speed range
400
There is no limitation on minimum speed nmin. If uniformity of
V 68
V

V 32
V 46
V

200 rotation is required, however, speed nmin should not be allowed


G
G

G
G
G

10
22

100 to fall below 50 rpm.


viscosity ν (mm2/s)

60 See table on page 6 for max. permissible speeds.


40 36
Installation position
νopt.
20 Any installation position possible. The motor housing must be
16 filled with fluid prior the commissioning, and must remain full
whenever it is operating.
10
For extensive information on installation postition, please consult
our data sheet RE 90270 before completing your design work.
5 5
-40° -25° -10° 0° 10° 30° 50° 70° 90° 115° Symbol A
temperature t (°C)
tmin = -40°C fluid temperature range tmax = +115°C Connections
A, B Service line ports
T Drain port
T B

4/28 Brueninghaus Hydromatik


RE 91001/01.97

Fixed Displacement Motor A2FM

Technical Data
Case drain pressure Flushing valve
The lower the speed and the case drain pressure the higher the In order to prevent excessive heat build-up in closed circuit
life expectation of the shaft seal ring. operation, it is possible to fit a flushing valve (built into the port
plate). Two such valves are available:
Shaft seal ring FPM (fluor-caoutchouc) - an Integrated flushing valve (built into the port plate) (sizes 23...90)
The values shown in the diagram are permissible loads of the - a built-on flushing and boost pressure relief valve (sizes 45...180, 250)
seal ring and shall not be exceeded.
Integrated flushing valve (6)
At stationary pressure loads in the range of the max. admissible
leakage pressure a reduction of the life experience of the seal - switching pressure ∆p ≥ 8 bar (this value is lower than the starting
pressure of an unloaded motor). T2 A (B)
ring will result.
For a short period (t < 5 min.) are for the sizes 10…200 pressure - closed in centre position (∆p < 8 bar).
loads up to 5 bar independent from rotational speeds are Sizes 23-32 45-63 80-90
permissible.
Flushing-
2,5 3,1 4,1
Sizes 10...200 volume L/min
10 (values given for low pressure
∆p = 25 bar) T1 B (A)
9
sizes 10,12,16 Built-on flushing and boost pressure relief valve (7)
8
perm. pressure pabs. max. (bar)

This valve is built on to the fixed displacement motor. It must then


7 be noted that only a port plate with ports at side is then available
sizes 23,28,32 (port plate 02).
6
size 45 The flushing and boost pressure relief valve has a fixed setting
5 of 16 bar (the setting of the primary boost pressure relief valve
sizes 80,90 sizes 56,63 must be noted) and is used to safeguard the minimum boost
4 pressure. A fixed flow of fluid is taken via an orifice from the low
sizes 107,125
3 pressure side of the circuit and fed into the motor housing. This
sizes 160,180 flow is then passed back to tank with the case drain fluid. Fluid
2 size 200 thus removed from the closed circuit must be made up by means
1 of the boost pump.
0 1000 2000 3000 4000 5000 6000 7000 8000 Different orifice sizes may be used to select varying flows of
speed n (rpm) flushing fluid.
Sizes 250...1000
4 Flows (at low pressure ∆p = 25 bar) *
Size Flow Orifice No.
size 250
3,5 45, 56, 63 3,5 L/min 651766/503.12.01.01
perm. pressure pabs. max. (bar)

3 80, 90 5 L/min 419695/503.12.01.01


size 355 107, 125 8 L/min 419696/503.12.01.01
2,5 160, 180 10 L/min 419697/503.12.01.01
size 500
size 710 250 10 L/min
2

1,5 * Standard flushing volumes T2 A (B)

size 1000 (for sizes 45…180 flushing


1 volumes of 3,5 - 10 L/min can
0 500 1000 1500 2000 2500 3000 be supplied. If a flushing
speed n (rpm) volume different from the
standard flushing volume is
Shaft seal ring NBR (nitril-caoutchouc) required, please indicate the
For seal rings of NBR 33% reduced values for the max. T B (A)
requested orifice in clear text 1
permissible housing pressure pabs.max. are to be considered when ordering).
compared with seals of FPM.
Long-Life bearings (L) (sizes 250...1000)
Special operation conditions may require limitations of these (for high life expectancy and use of HF-fluids)
values.
The outer dimensions of the axial piston motors are identical to
Note: standard design (without long life bearings). The change from
- maximum permissible motor speeds are given in the table on standard design to long life bearing system is possible.
page 6 We recommend to apply bearing flushing at port U.
- max. perm. housing pressure pabs. max __ 10 bar (sizes 5...200)
Bearing flushing
__ 4 bar (sizes 250…1000)
For sizes 250…1000 bearing and housing flushing is possible
- the pressure in the housing must be the same as or greater than
through port U.
the external pressure on the shaft seal.

Brueninghaus Hydromatik 5/28


RE 91001/01.97

Fixed Displacement Motor A2FM

Technical Data
Working pressure range Speed sensor (D) (sizes 23...180)
Maximum pressure at port A or B Version A2FM…D ("suitable for fitting speed sensor") includes
(Pressure data to DIN 24312) gearing on the rotary group and in addition the port M in which
a speed sensor is screwed in.
Size 5 Shaft end B Shaft end C
A speed-proportional signal is produced by means of the
Nominal pressure pN 210 bar 315 bar rotating, splined rotary group which can be picked up by a
Peak pressure pmax 250 bar 350 bar suitable sensor and fed back for evaluation.
The speed sensor can be screwed into port M (thread M18x1,5).
Sizes 10...200 Shaft end A Shaft end Z, B, P
Sizes 23...32 45 56...63 80...90 107...125 160...180
Nominal pressure pN 400 bar 350 bar *) No. of teath 38 45 47 53 59 67
Peak pressure pmax 450 bar 400 bar
length of
*) Attention: shaft end Z and P with drives of radial force loads at 12,7 11,2 14,7 14,7 14,7 14,7
thread (mm)
the drive shaft (pinion V-belt drives) necessitate reduction of the The speed sensor is not included in standard supply.
nominal pressure to pN = 315 bar (please contact us).
Suitable sensors (order seperately):
- Induktive impulse detector ID (see RE 95038)
Sizes 250...1000 - Hall effect speed sensor HD (see RE 95042)
Nominal pressure pN 350 bar
Peak pressure pmax 400 bar

With pulsating loads above 315 bar we recommend using the


model with splined shaft, standard version A (sizes 10…200)
or with splined shaft Z (sizes 250…1000).
The summ of the pressures at ports A and B may not exceed
700 bar (630 bar, A2F 5).

Table of values (theoretical values, without considering ηmh and ηv; values rounded)
Size 5 10 12 16 23 28 32 45 56 63 80
3
Displacement Vg cm 4,93 10,3 12 16 22,9 28,1 32 45,6 56,1 63 80,4
Max. speed nmax rpm 10 000 8000 8000 8000 6300 6300 6300 5600 5000 5000 4500
1
nmax intermittent ) rpm 11 000 8800 8800 8800 6900 6900 6900 6200 5500 5500 5000
Max. flow qV max L/min 49 82 96 128 144 176 201 255 280 315 360
Torque constants TK Nm/bar 0,076 0,164 0,19 0,25 0,36 0,445 0,509 0,725 0,89 1,0 1,27
Torque at ∆p = 350 bar T Nm 24,7 2) 57 67 88 126 156 178 254 312 350 445
∆p = 400 bar T Nm – 65 76 100 144 178 204 290 356 400 508
Case volume L 0,17 0,17 0,17 0,20 0,20 0,20 0,33 0,45 0,45 0,55
Moment of inertia
J kgm2 0,00008 0,0004 0,0004 0,0004 0,0012 0,0012 0,0012 0,0024 0,0042 0,0042 0,0072
about drive axis
Weight (approx) m kg 2,5 5,4 5,4 5,4 9,5 9,5 9,5 13,5 18 18 23
Size 90 107 125 160 180 200 250 355 500 710 1000
Displacement Vg cm3 90 106,7 125 160,4 180 200 250 355 500 710 1000
Max. speed nmax rpm 4500 4000 4000 3600 3600 2750 2500 2240 2000 1600 1600
1
nmax intermittent ) rpm 5000 4400 4400 4000 4000 3000 – – – – –
Max. flow qV max L/min 405 427 500 577 648 550 625 795 1000 1136 1600
Torque constants TK Nm/bar 1,43 1,70 1,99 2,54 2,86 3,18 3,98 5,64 7,95 11,3 15,9
Torque at ∆p = 350 bar T Nm 501 595 697 889 1001 1114 1391 1979 2785 3955 5570
∆p = 400 bar T Nm 572 680 796 1016 1144 1272 – – – – –
Case volume L 0,55 0,8 0,8 1,1 1,1 2,5 3,5 7,8
Moment of inertia
J kgm2 0,0072 0,0116 0,0116 0,0220 0,0220 0,0378 0,061 0,102 0,178 0,55 0,55
about drive axis
Weight (approx.) m kg 23 32 32 45 45 66 73 110 155 322 336
1
) Intermittent max. speed: overspeed at discharge and overtaking travel operations, t < 5 sec. and ∆p < 150 bar
2
) ∆p = 350 bar

6/28 Brueninghaus Hydromatik


RE 91001/01.97

Fixed Displacement Motor A2FM

Technical Data
Output drive
Permissible axial and radial loads on drive shaft
The values given are maximum values and do not apply to continuous operation

Size 5 10 12 16 23 28 32 45 56 63 80
a mm 12 16 16 16 16 16 16 18 18 18 20
Fq max N 710 2350 2750 3700 4300 5400 6100 8150 9200 10300 11500
±Fax max N 180 320 320 320 500 500 500 630 800 800 1000
±Fax perm. /bar N/bar 1,5 3,0 3,0 3,0 5,2 5,2 5,2 7,0 8,7 8,7 10,6

Size 90 107 125 160 180 200 250 355 500 710 1000
a mm 20 20 20 25 25 25 41 52,5 52,5 67,5 67,5
Fq max N 12900 13600 15900 18400 20600 22900 12001) 15001) 19001) 30001) 26001)
±Fax max N +Fax max 1000 1250 1250 1600 1600 1600 4000 5000 6250 10000 10000
- Fax max 1000 1250 1250 1600 1600 1600 1200 1500 1900 3000 2600
±Fax perm. /bar N/bar 10,6 12,9 12,9 16,7 16,7 16,7 2
) 2
) 2
) 2
) 2
)
1
) Axial piston unit in stationary or in bypass operation, please contact us when appearing higher forces!
2
) Please contact us!

Code explanation
a = distance of Fq from shaft shoulder The direction of the max. perm. axial force must be noted by
Fq max = max. perm. radial force at distance a sizes 5…200
(at intermittent operation) − Fax = increases bearing life
±Fax max = max. perm. axial force when stationary + Fax = reduces bearing life
or when axial piston unit is running at zero pressure (avoid if possible)
±F ax perm./bar = perm. axial force/bar operating pressure

Calculation of size Optimal force direction of Fq (valid for sizes 10...180)


By means of appropriate force directions of Fq the bearing load
Vg • n caused by inside rotary group forces can be reduced. An optimal
Flow qV = in L/min
1000 • ηv life expectation of the bearing can be reached.

qV • 1000 • ηv
Output speed n = in rpm
Vg ° ϕop
alternating = 45 t =4

rotation ϕ opt
Vg • ∆p • ηmh
Output torque T =
20 • π 0° ϕo
=7 pt =7
1,59 • Vg • ∆p • ηmh ϕo
pt

= in Nm
100
T = TK • ∆p • ηmh in Nm

2π•T•n T•n
Output power P = =
60 000 9549 A B A B
qV • ∆p
= • ηt in kW
600 anti-clockwise rotation clockwise rotation anti-clockwise rotation
pressure at port B pressure at port A pressure at port B
3
Vg = geometric displacement per rev. in cm
T = torque in Nm
∆p = pressure differential in bar
n = speed in rpm
TK = torque constants in Nm/bar
ηv = volumetric efficiency
ηmh = mech.-hyd. efficiency
ηt = overall efficiency

Brueninghaus Hydromatik 7/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 5

8
Y
70 Detail Y
74 R6
17, 58, ,5 T
5 5
A
ø60 h8

70
25° 0,1
±

6,4
75

ø48,5

62
4
T T
51 80

Connections B
A, B Service line ports M 18x1,5
T Drain port M 10x1, both sides

Shaft ends

B Parallel shaft with C Tapered shaft with spigot


key A4x4x20 and spring washer 3x5
DIN 6885 DIN 6888
4
7,3

33
24 22
ø12,8
M10x1
ø12k6
13,5

M4

10 ,4
R0
taper 1:10
Nominal pressure Nominal pressure
pN = 210 bar pN = 315 bar

Ordering Code / Standard Program


Size 5 A2F 5 W 6.0 3 Additional instructions in text form

Axial piston unit Seals


Bent axis design, fixed displacement A2F The fixed motor A2F5 is equipped with NBR (Nitril-
caoutchouc) seals in standard design. In case of
Size need FPM- (fluor-caoutchouc) seals please
indicate when ordering in clear text:
Displacement Vg (cm3) 5
"with FPM-seals"
Direction of rotation
viewed on shaft end alternating W

Series
6.0

Shaft end
Parallel shaft with key DIN 6885 B
Tapered shaft with spigot and spring washer DIN 6888 C
= preferred program
Service line connections (preferred types see page 22)
Threads at side, metric 3

8/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 10, 12, 16


64,5 45° 45°
20 12
95
6 T1 5
R 10
se
e
po
rt
°
ø80 h6

pla
,5
40

te

95
41
s
0
10
53,5

9
18,2

T2 5 A B
ø8

Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 12x1,5

Shaft ends

Sizes 10, 12, 16 Sizes 10, 12 Sizes 10, 12, 16 Sizes 10, 12
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 25x1,25x30x18x9g W 20x1,25x30x14x9g key AS 8x7x32 key AS 6x6x32
DIN 5480 DIN 5480 DIN 6885 DIN 6885

22
E1x0,2 E1x0,2
R1

16 DIN 509
R

DIN 509
,6

1,
2

ø25 k6
M 10

ø20 k6
M 10

ø24,6
ø21,6

ø19,6
ø16,6

22,5
M6

28

M6
6 12 22 2,5 16 2,5
28 34 40 40

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

Port plates
03 04

10
8 10
8 B1 A1
55,5
55,5

69,5
91

B A B A
91

130,5
130,5 85 147 36
166 166 85

A, B Service line ports M 22x1,5 A, B, A1, B1 Service line ports M 22x1,5

Brueninghaus Hydromatik 9/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 23, 28, 32

45°
60,7 45 °
25 18
8
T1 118
se R 12
19 e
po
rt
pl
at
es
h6

40 °

118
,5
ø100

48

5
12
55,5

19

11
23,2
A B
06

T2
ø1

Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 16x1,5

Shaft ends

Sizes 23, 28, 32 Sizes 23, 28 Sizes 23, 28, 32 Sizes 23, 28
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 30x2x30x14x9g W 25x1,25x30x18x9g key AS 8x7x40 key AS 8x7x40
DIN 5480 DIN 5480 DIN 6885 DIN 6885

22
E1x0,2 E1x0,2
R1

19 DIN 509
R

DIN 509
,6

1,
6

ø30 k6
M 10

ø25 k6
M 10
ø24,6

ø24,6
ø29,6
ø21,6
M8

33

M8
28

8 15 22 19
35 43 50 50

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M


(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042,
to be ordered separately!)

60,7
2 M M 18 x 1,5
53
50

10/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Sizes 23, 28, 32 Port plates


01 02

12 115 13
1 40,5 40,5 7

B A 18
,2

18,2

13 ,5
40

70
78
106
B A

117
M8; 15 deep M8; 15 deep
153 13
173 59 144
190 120

A, B Service line ports SAE 1/2" A, B Service line ports SAE 1/2"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series

03 04

13 13
7 7
B1 A1

88
70

70

117
B A B A
117

144 144
190 120 166 58
190 120

A, B Service line ports M 27x2 A, B, A1, B1 Service line ports M 27x2

10 19 (see page 28)

14 Detail Y
9
40
13

40,5
106

B
91

115
59

40,5

158
A
178 M8; 15 deep
18,2

A, B Service line ports SAE 1/2"


420 bar (6000 psi) high pressure series

Brueninghaus Hydromatik 11/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 45


45 °
60,3 45°

32 20
T1 150
12
se R 16
18 e
po
rt
pla
te
ø125 h6

40 °

150
52

13,5
16
63

18

30
18

A B
ø1

T2
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5

Shaft ends

A Splined shaft Z Splined shaft P Parallel shaft with


W 32x2x30x14x9g W 30x2x30x14x9g key AS 8x7x50
DIN 5480 DIN 5480 DIN 6885

28 28 E1x0,2
DIN 509
R1

R1
,6

,6
M 12

M 12

ø30 k6

ø29,6
ø26,6

ø24,6

M 12
33

8 8
28
35 35
60

Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 223
to be ordered separately!)

60,3
5,5 M M 18 x 1,5 Y
54,5

151

Detail Y A

B
98

12/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Size 45 Port plates


01 02

147 15
13 5
8 50,8 50,8

B A 23
,8

19 8
,
50

80
23,8
89

B A
122

133
M 10; 17 deep M 10; 17 deep
166 19 155 128
194 75 207

A, B Service line ports SAE 3/4" A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series

04 10

15 16 Detail Y
5 7 49
B1 A1

50,8
B

19
100

119
80

B A
102
133

147
75

50,8
A
155 58 169
179 128 193 23,8
207 M 10; 17 deep

Y
A, B, A1, B1 Service line ports M 33x2 A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series

19 (see page 28)

Brueninghaus Hydromatik 13/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 56, 63


45°
67,5 45 °
32 20 T1 150
10
se R 16
18 e
po
rt
pl
at
es
ø125 h6

40 °

150
56

13,5
16
70

18

30
A B
28
ø1

T2
Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5

Shaft ends

Sizes 56, 63 Size 56 Sizes 56, 63 Size 56


A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 35x2x30x16x9g W 30x2x30x14x9g key AS 10x8x50 key AS 8x7x50
DIN 5480 DIN 5480 DIN 6885 DIN 6885

28 28 E1x0,2 E1x0,2
R1 DIN 509
,6 DIN 509
R1
,6
M 12

M 12

ø30 k6
ø34,6
ø35 k6
ø24,6
ø29,6

M 12

ø29,6
M 12
38

33

8 8
28 2,5 28 2,5
40 35
60 60

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
239
hall effect speed sensor HD see RE 95042,
to be ordered separately!)

Y
67,5
6 M M 18 x 1,5
159
60

Detail Y
A
98

14/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Sizes 56, 63 Port plates


01 02

14 147 16
9, 6,
5 50,8 50,8 5

B A 23
,8

19 ,8
50
96

87
23,8
130

B A

142
M 10; 17 deep M 10; 17 deep
182 19 171
206 75 225 136

A, B Service line ports SAE 3/4" A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series

04 10

17 Detail Y
16 6
6, 49
5
B1 A1

50,8
B

19
107
87

107

147
142

75
B A

130

50,8
A
171 182
195 58 206 23,8
M 10; 17 deep
225 136

A, B, A1, B1 Service line ports M 33x2 A, B Service line ports SAE 3/4"
420 bar (6000 psi) high pressure series

19 (see page 28)

Brueninghaus Hydromatik 15/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 80, 90


45 °
78,5 45 °
32 20 T1 165
10
se R 16
15 e
po
rt
pl
at
es
40 °
ø140 h6

165
61

13,5
18
83

15

29
38

T2 A B
ø1

Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5

Shaft ends

Sizes 80, 90 Size 80 Sizes 80, 90 Size 80


A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 40x2x30x18x9g W 35x2x30x16x9g key AS 12x8x56 key AS 10x8x56
DIN 5480 DIN 5480 DIN 6885 DIN 6885

36 28 E1x0,2
R
E1x0,2
1, DIN 509 DIN 509
R2

6
,5

ø40 k6
M 16

M 12

ø35 k6
M 12
M 16
ø34,6

ø39,6

ø34,6
ø29,6

43

38

8 8 28 2,5
40 36 2,5
45 70
70

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 268
to be ordered separately!)
78,5
M M 18 x 1,5
6 Y
65,8

173,5

Detail Y A
98

16/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Sizes 80, 90 Port plates


01 02

16 18
2, 166 9,
5 5
57,2 57,2
B A 27
,8

,2
104,5

57

99
25
27,8
145

B A

162
M 12; 17 deep
203 M 12; 17 deep
25 160
233 196
84
257

A, B Service line ports SAE 1" A, B Service line ports SAE 1"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series

10

19
8 Detail Y
60

57,2
B

25
145

166
84
121

57,2
A
206
27,8
236 M 12; 17 deep

A, B Service line ports SAE 1"


420 bar (6000 psi) high pressure series

19 (see page 28)

Brueninghaus Hydromatik 17/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 107, 125 Dimensions brackets for size 107
45 °
45 °
82,8
40 23 190
T1
10
R 20
se
18 e
po
rt
pl
at
ø160 h6

40 °

es

190
67

17,5
20
85

18

36,5
A B
5 0

T2
ø1

Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 18x1,5

Shaft ends

Sizes 107, 125 Size 107 Sizes 107, 125 Size 107
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 45x2x30x21x9g W 40x2x30x18x9g key AS 14x9x63 key AS 12x8x63
DIN 5480 DIN 5480 DIN 6885 DIN 6885

36 28 E1x0,2 E1x0,2
R2 DIN 509
,5 DIN 509
R2
,5

ø40 k6
ø45 k6
M 16

ø44,6
ø34,6
M 12
ø39,6

M 12

ø39,6
M 16
48,5

43

8 8
36 2,5 28 2,5
50 45
80 80

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M with built-on flushing and boost valve (7)
(inductive impulse detector ID see RE 95038
hall effect speed sensor HD see RE 95042, 294
to be ordered separately!)

82,8 M M 18 x 1,5
8 Y
75

192

Detail Y A
98

18/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Sizes 107, 125 Port plates Dimensions brackets for size 107
01 02

18 194
6,
5 66,7 66,7 22
2
B A 31
,8
(2

(2 ,2)
7,
120

32 (57
8)

31,8

5)
,7
159

66

110
B A
M 14; 19 deep

181
225,5 32
252 99 M14; 19 deep
(M12; 17 deep) 178
213
285

A, B Service line ports SAE 11/4" A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series (SAE 1")

10

22 Detail Y
4
70

66,7
B

32
136
157

194
99

66.7
A
226
261
M 14; 19 deep
31,8
Y

A, B Service line ports SAE 11/4"


420 bar (6000 psi) high pressure series

19 (see page 28)

Brueninghaus Hydromatik 19/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Sizes 160, 180


° 45 °
93 45
40 25 210
T1
10
se R 20
19 e
,5 po
rt
pl
at
ø180 h6

40°

210
es
,5
77

17,5
22
95,5

19,5

37,2
A B
80

T2
ø1

Connections
A, B Service line ports (see port plates)
T1, T2 Drain ports (1 port plugged) M 22x1,5

Shaft ends

Sizes 160, 180 Size 160 Sizes 160, 180 Size 160
A Splined shaft Z Splined shaft B Parallel shaft with P Parallel shaft with
W 50x2x30x24x9g W 45x2x30x21x9g key AS 14x9x70 key AS 14x9x70
DIN 5480 DIN 5480 DIN 6885 DIN 6885

36 36

R2
R2

R4

,5
R2

,5
,5

ø50 k6
M 16

ø45 k6
M 16

ø39,6
ø44,6

48,5

M 16
M 16
53,5

11 8 36
36
55 50
90 90

Nominal pressure Nominal pressure Nominal pressure Nominal pressure


pN = 400 bar pN = 350 bar pN = 350 bar pN = 350 bar

prepared for speed sensing control (D), with port M


(inductive impulse detector ID see RE 95038 with built-on flushing and boost valve (7)
hall effect speed sensor HD see RE 95042, 315
to be ordered separately!)

93 M M 18 x 1,5 Y
2
83

201

Detail Y A
98

20/28 Brueninghaus Hydromatik


RE 91001/01.97

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Sizes 160, 180 Port plates


01 02

20 194 23
8 3
66,7 66,7
B A 31
,8

,7
66

121
32
134

31,8
B A
188

188
M 14; 19 deep M 14; 19 deep
252 32 237 202
294 99
294

A, B Service line ports SAE 11/4" A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series 420 bar (6000 psi) high pressure series

10

24 Detail Y
4
70

66,7
32
B

185

194
99
149

66,7
A
252
290 M 14; 19 deep 31,8

A, B Service line ports SAE 11/4"


420 bar (6000 psi) high pressure series

19 (see page 28)

Brueninghaus Hydromatik 21/28


RE 91001/01.97

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 200 45 ° 45 °


Shaft ends
40 104
236
9 32 T 199
15 A Splined shaft 36

22
W 50x2x30x24x9g R4
DIN 5480
ø200 -0,029

25°

M 16
92

ø44,6
236
0
25
102,5

84
15

211

165
55
32 T A B
284 B Parallel shaft with
309 204 key AS 14x9x70
66,7 66,7

R2
DIN 6885
B A

,5
ø50 k6
M 16
53,5
Connections

31,8
A, B Service line ports SAE 11/4"
36 11
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 22x1,5 90
32 M 14;
99 deep
19 tief

Preferred types, please state type and ident-no. when ordering


Type Ident-No. Type Ident-No.
A2F5W6.0B3 9404451 A2FM80/61W-PAB010 9422638
A2FM10/61W-PAB030 9423386 A2FM80/61W-PAB020 9422089
A2FM10/61W-PBB030 9610656 A2FM80/61W-PBB010 9610666
A2FM80/61W-PBB020 9610667
A2FM12/61W-PAB030 9424240
A2FM12/61W-PBB030 9610657 A2FM90/61W-PAB010 9408463
A2FM90/61W-PAB020 9408464
A2FM16/61W-PAB030 9411111 A2FM90/61W-PBB010 9408468
A2FM16/61W-PBB030 9411119 A2FM90/61W-PBB020 9408469
A2FM23/61W-PAB010 9427351 A2FM107/61W-PAB010 9424300
A2FM23/61W-PAB020 9422092 A2FM107/61W-PAB020 9424093
A2FM23/61W-PAB040 9428415 A2FM107/61W-PBB010 9610668
A2FM23/61W-PBB010 9610658 A2FM107/61W-PBB020 9610669
A2FM23/61W-PBB020 9610659
A2FM125/61W-PAB010 9409630
A2FM23/61W-PBB040 9610660
A2FM125/61W-PAB020 9409634
A2FM28/61W-PAB010 9424853 A2FM125/61W-PBB010 9409637
A2FM28/61W-PAB020 9422548 A2FM125/61W-PBB020 9409638
A2FM28/61W-PAB040 9421629
A2FM160/61W-PAB010 9425163
A2FM28/61W-PBB010 9610661
A2FM160/61W-PAB020 9424094
A2FM28/61W-PBB020 9610662
A2FM160/61W-PBB010 9610670
A2FM28/61W-PBB040 9610663
A2FM160/61W-PBB020 9610671
A2FM32/61W-PAB010 9410189
A2FM180/61W-PAB010 9409189
A2FM32/61W-PAB020 9410190
A2FM180/61W-PAB020 9409190
A2FM32/61W-PAB040 9410192
A2FM180/61W-PBB010 9409372
A2FM32/61W-PBB010 9410194
A2FM180/61W-PBB020 9409373
A2FM32/61W-PBB020 9410195
A2FM32/61W-PBB040 9410197 A2FM200/63W-PAB010 2011528
A2FM45/61W-PZB010 9411581 A2FM250/60W-VZB010 915383
A2FM45/61W-PZB020 9411582 A2FM250/60W-VPB010 914475
A2FM45/61W-PZB040 9411584 A2FM250/60W-VZB020 910653
A2FM250/60W-VPB020 930970
A2FM56/61W-PAB010 9424905
A2FM56/61W-PAB020 9422129 A2FM355/60W-VZH010 920780
A2FM56/61W-PAB040 9429251 A2FM355/60W-VPH010 929843
A2FM56/61W-PBB010 9610664 A2FM500/60W-VZH010 968982
A2FM56/61W-PBB020 9610665 A2FM500/60W-VPH010 943251
A2FM56/61W-PBB040 9605544
A2FLM710/60W-VZH010 965974
A2FM63/61W-PAB010 9408523 A2FLM710/60W-VPH010 969815
A2FM63/61W-PAB020 9408524
A2FM1000/60W-VZH010 944773
A2FM63/61W-PAB040 9408526
A2FM63/61W-PBB010 9408514 A2FM1000/60W-VPH010 949444
A2FM63/61W-PBB020 9408549 sizes 5...200: production plant Elchingen
A2FM63/61W-PBB040 9408551 sizes 250...1000: production plant Horb

22/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 250


Port plate 01
288
45° 45°
50 82 Detail X
9 22 246 66,7 66,7
U T
B A

124

31,8
105

22
ø224 h8

210
246
0´ 0
105

28
26°3

93
M14; 19 deep

25 172 32 32
T X 50 50
82
314

Port plate 02 Detail X


267 236
U T with built-on flushing and
boost valve (7)
105

B A

210

105

26°3

82
172
32
7
66,

T
X
323 344

Connections
A, B Service line ports SAE 11/4"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 22x1,5
U Port for bearing flushing (plugged) M14x1,5

Shaft ends
Z Splined shaft P Parallel shaft with
W 50x2x30x24x9g key AS 14x9x80
DIN 5480 DIN 6885

36
R1

R2
,5
,6
ø50 k6
M 16

M 16
53,5
ø45

9 36
58
82

Nominal pressure Nominal pressure


pN = 350 bar pN = 350 bar

Brueninghaus Hydromatik 23/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 355

320 22°30´
50 83
14 23,5 ° 335
45
U T

170
36
128

0
ø280 h8

18

26°3

102
0
32

335
128

198

28 T X
83
350 Detail X
36,6 36,6

B A

245
79,4
Connections
A, B Service line ports SAE 11/2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 33x2
U Port for bearing flushing (plugged) M 14x1,5 M16; 21 deep

40 40

60 60

Shaft ends
Z Splined shaft P Parallel shaft with
W 60x2x30x28x9g key AS 18x11x100
DIN 5480 DIN 6885

42
R1

R4
,6
ø60 m6
M 20

M 20
64,4
ø55

11 42
82
105

Nominal pressure Nominal pressure


pN = 350 bar pN = 350 bar

24/28 Brueninghaus Hydromatik


RE 91001/01.97

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 500

361,5 22°30´
50 98
°
14 27,5 45 375

U T

192
142 40
0

22
ø315 h8

375

112,5
26°3

0
36
142

220 X
30 T
111
396 Detail X 36,6 36,6

B A

270
79,4
Connections
A, B Service line ports SAE 11/2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 33x2
U Port for bearing flushing (plugged) M 18x1,5 M16; 21 deep

40 40
65 65

Shaft ends
Z Splined shaft P Parallel shaft with
W 70x3x30x22x9g key AS 20x12x100
DIN 5480 DIN 6885

42
R1

R4
6,
ø70 m6
ø62,7
M 20

M 20
74,5
74,4

13 42
80
105
Nominal pressure Nominal pressure
pN = 350 bar pN = 350 bar

Brueninghaus Hydromatik 25/28


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 710

486 22°30´
50 131
14 41,5 465

°
45
U T

236
50
183

465
22
ø400 h8

´
18°30

102
0
45
183

252 X

35 T
156
507 Detail X 44,5 44,5

B A

340
96,8
Connections
A, B Service line ports SAE 2"
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 42x2
U Port for bearing flushing (plugged) M18x1,5 M20; 30 deep

50 50
85 85

Shaft ends
Z Splined shaft P Parallel shaft with
W 90x3x30x28x9g key AS 25x14x125
DIN 5480 DIN 6885

50
R1

R4
,6
ø90 m6
M 24

ø82,6

M 24
95

14 50
105
130

Nominal pressure Nominal pressure


pN = 350 bar pN = 350 bar

26/28 Brueninghaus Hydromatik


RE 91001/11.95

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Unit Dimensions, Size 1000

22°30´
468
50 131
° 465
14 41,5 45
U T

236
50
183
0

22
ø400 h8

465

143
26°3

0
45
183

279 X
35 156 T
512
Detail X
44,5 44,5

Connections

340
96,8
A, B Service line ports SAE 2" B A
420 bar (6000 psi) high pressure series
T Drain port (1 port plugged) M 42x2
U Port for bearing flushing (plugged) M18x1,5
M20; 30 deep

50 50
85 85

Shaft ends
Z Splined shaft P Parallel shaft with
W 90x3x30x28x9g key AS 25x14x125
DIN 5480 DIN 6885

50
R1

R4
6,
ø90 m6
M 24

ø82,6

M 24
95

14 50
105
130
Nominal pressure Nominal pressure
pN = 350 bar pN = 350 bar

Brueninghaus Hydromatik 27/28


RE 91001/01.97

Fixed Displacement Motor A2FM Before finalising your design, please request a certified drawing.

Port plate 19, with integrated pressure relief valves

Port plate 191 Port plate 192


D1 (pressure relief valves without (pressure relief valves with
D2 pressure sequence range) pressure sequence range)
D5 D2 pSt
T1 T2 T1 T2

D3
T1

D4
MA MA MB
MB
pSt pSt
D7

Z
D6

T2
A S1 B A S1 B
Detail Y MB S1 MB S1
D10
Y Y
D12
B Detail Z
Pressure relief
Pressure relief valves
D8 valves - without pressure sequence range (1) - with pressure sequence range (2)
MHDBN16 (Sizes 28...45) MHDBB16 (Sizes 28...45)
D11

MHDBN22 (Sizes 56...90) MHDBB22 (Sizes 56...90


MHDBN32 (Sizes 107...180) MHDBB32 (Sizes 107...180)
D9

S1 Connections
A, B Service line ports SAE, 420 bar
A MB MA
(6000 psi high pressure series)
D13
S1 Boosting
pSt Pilot pressure port G 1/4
MA, MB Test ports (plugged)

Size D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 Ports A, B Port S1 Ports MA,MB


28 209 186 25 63 174 102 87 36 66 50,8 23,8 19 M10; 17 deep SAE 3 /4" M 22x1,5 M 20x1,5
32 209 186 25 63 174 102 87 36 66 50,8 23,8 19 M10; 17 deep SAE 3 /4" M 22x1,5 M 20x1,5
45 222 198 22 60 187 113 98 36 66 50,8 23,8 19 M10; 17 deep SAE 3 /4" M 22x1,5 M 20x1,5
56 250 222 19 57 208 124 105 42 75 50,8 23,8 19 M10; 13 deep SAE 3 /4" M 26x1,5 M 26x1,5
63 250 222 19 57 208 124 105 42 75 50,8 23,8 19 M10; 13 deep SAE 3 /4" M 26x1,5 M 26x1,5
80 271 243,5 17,5 55 229 134 114 42 75 57,2 27,8 25 M12; 18 deep SAE 1" M 26x1,5 M 26x1,5
90 271 243,5 17,5 55 229 134 114 42 75 57,2 27,8 25 M12; 18 deep SAE 1" M 26x1,5 M 26x1,5
107 298 267 10 48 251 149,5 130 53 84 66,7 31,8 32 M14; 19 deep SAE 11 /4" M 26x1,5 M 26x1,5
125 298 267 10 48 251 149,5 130 53 84 66,7 31,8 32 M14; 19 deep SAE 11 /4" M 26x1,5 M 26x1,5
160 5 43 170 149 53 84 66,7 31,8 32 M14; 19 deep SAE 11 /4" M 26x1,5 M 30x1,5
180 5 43 170 149 53 84 66,7 31,8 32 M14; 19 deep SAE 11 /4" M 26x1,5 M 30x1,5

Brueninghaus Hydromatik GmbH, Plant Elchingen, Glockeraustraße 2, D–89275 Elchingen, Tel. (07308) 820, Telefax (07308) 7274
Plant Horb, An den Kelterwiesen 14, D–72160 Horb, Tel. (07451) 920, Telefax (07451) 8221

28/28 Brueninghaus Hydromatik The specified data is for product description purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the contract. All rights reserved – Subject to revision

S-ar putea să vă placă și