Sunteți pe pagina 1din 4

boilersinfo.com Email ID -xxxxxxxxxxx@gmail.

com
Mobile No. xxxxxxxxx

DIPLOMA ELECTRICAL Total Exp:7 Year

OBJECTIVE

To achieve a responsible and challenging position in industry to practice my knowledge and ability.

Technical Qualification

Degree College Board/University Percentage Year of Passing


R.M.S Technical Examination
DIPLOMA ELECTRICAL 62.61% June 2008
Polytechnic Board
(Reliance)
I.T.I. APPRENTICESHIP N.C.V.T 78.42% March 2004
I.P.C.L. Baroda
I.T.I. I.T.I. Tarsali
Gov. of Gujarat 77.28% March 2002
ELECTRICIAN Baroda

Automation & Software Skills

DATA ENTRY-MS-OFFICE Directorate of Employment


Gov. of Gujarat,india 2002
OPERATOR & Training, Gandhinagar
ELECTRO-PNEUMATIC Hi-Tech Training
Gov. of Gujarat 2005
CONTROLS I.T.I. Tarsali , Baroda
Hi-Tech Training
AUTO CAD 2D-3D Gov. of Gujarat 2008
I.T.I. Tarsali , Baroda

LICENCE :- 2nd Class Wireman Certificate

I have PERMIT FOR ELECTRICAL SUPERVISOR (Permit No: G/GS-E-001494-DEE-2009)

PROFFESIONAL EXPERIENCE

GUJARAT INDUSTRIES POWER COMPANY LTD, india . (OCT-2011 TO Till Date)


Sr.Tech.Electrical Operation Dept.

ELECTRICAL (Operation & Maintenance) Dept. (Total 125 x 4 MW Thermal Power Plant)

Company Profile

 GIPCL has 500 MW Independent Power Plant (IPP).GIPCL has Semi Government based Company. His
Power Distributed to GEB. Company Having CFBC Boiler of 390 TPH steam generation capacity. Our
TG set is made of BHEL. Having Siemens make DCS System.

Nature of Work:

 Work Permit Issue of All Electrical Equipment & Change over Equipment as per LOTO system used for
isolation.

 Day to day breakdown maintenance and trouble shooting of above equipments.

 Planning, scheduling and execution of annual overhauling shutdown activities.

 Day to day allocation of jobs and recourses to contract workers, supervision if workmanship, training
of contract workers.

 Attended Tripping, Emergency & Failure Of 6.6 K.V & 415V MCC, D.G Set, UPS , Battery Charger ,
Other Critical Equipment And Restore The Power As Earlier As Possible.

 Attending Power Plant Black out Condition of continuous process plant

 Check Dc Voltage, batteries and battery chargers.

 Operation & Maintenance Work for H.T. (6.6 Kv) And L.T. Induction Motors ( Rating Up To 2000 KW )

 6.6 Kv ABB Make Sf6 Breakers, JYOTI MAKE VACCUM Circuit Breaker (Rating Up To 2500 Amp )

 LT Breakers Of Siemens And GEC Make Type –Air Circuit Breakers (Rating Up To 3150 Amp.)

 Transformers Of BHEL, Voltamp, EMCO, and KIRLOSKER Make (Rating From 500 KVA To 150 MVA.)

 HT (6.6 Kv) Switchgear Panels Make ABB, JYOTI and LT (415v) Switchgear Panels Make SIEMENS and
CONTROL SWITCHGEAR.

 Operation of ELECTRO STATIC PRESIPITATOR.

ADANI POWER LTD (330 X 4 MW & 660 X 5 unit Thermal Power Plant)
Total Capacity 4620 MW (MAY-2010 TO SEP 2011)

Designation: Assistant (Operation & Maintenance) Dept.


 Trouble shooting & Preventive Maintenance of all electrical equipments.
 Repairing, Testing and Trouble shooting of all electrical equipments.
 Preventive Maintenance & Overhauling of LT & HT motors.
 Cable joint of LT & HT Cables.
 Erection, Commissioning & Testing of 2000 Kg Boilers Lift (Make: China)
 Preventive Maintenance of HT Panels of 6.6KV & 11KV & HT Motors.
 Preventive Maintenance of LT Panels(MCC & PCC) & LT Motors.
 Preventive Maintenance of E.O.T Crain.
 Testing of Transformers.
 Preventive Maintenance of Battery Bank.
 I use many type Fault Located kit Like.
(1) Online Earth Fault Kit. ( Ground Fault online Tester )
(2) Transformers oil Testing kit.(BDV Test)
(3) Megger Insulation Tester Kit. ( L.T & H.T )

DIAMOND POWER INFRASTRUCTURE LTD,


(SEP-2009 TO APRIL-2010)

Designation: Trainee Engineer (Q.C) (Testing of power cables & conductors)

 In process quality checks


 Maintaining ISO Records of Cables and conductors
 Testing of the cables (PVC, XLPE and FRLS) and Raw material testing
 Dispatch of cables and conductors
 Preparing monthly QC Reports
 Cable High Voltage Testing
 Conductor Resistant Testing
 Cable Meggering Testing
 Cable Repairing & Testing
 All type cable inspection & preparing Routine, Type test & Acceptance Test Reports.
 Hand one experience all types production related activities.
 All types of Cable manufacturing knowledge.
 All types of format with using process.
 Knowledge about production planning and make a job card as per checklist.
 All type of machinery knowledge like Laid up, Armouring, Extruder, Drum twister.
 Also knowledge about dispatch side.
 Knowledge about ISO system.
 Make a good knowledge to utilize a man power.
 Knowledge of Curing System.

I.P.C.L. Baroda. (Reliance) baroda, india. ( April 2003 to March 2004 )


Designation : Apprenticeship Trainee IN (GAS TURBINE POWER PLANT) (G.T.P.P)
One year apprenticeship training for Electrical Maintenance in GTPP(Gas Turbine Power Plant 30x2=60Mw
in Indian Petrol Chemicals Ltd.
 Preventive Maintenance & Overhauling of LT & HT Motors.
 Cable joint of LT & HT Cables.
 Total Maintenance of Ceiling Fan , tub light , Hand lamp , Table fan.
 Total Maintenance of Plant lighting.
 Testing of Transformers oil. (BDV Test)
 Preventive & Breakdown Maintenance.
 Preventive Maintenance of Battery Bank.

PERSONAL INFORMATION
NAME Suthar Varun BhanuBhai

xxxxxx
ADDRESS Makarpura Road,
xxxxxxxxxxxxx

DATE OF BIRTH xxxxxxxx


GENDER xxxxxxx
NATIONALITY xxxxxxxxxx
RELIGION xxxxxxxxxx
LANGUAGE KNOWN Gujarati , Hindi, & English
CONTACT NUMBER xxxxxxxxx
EMAIL ADDRESS xxxxxxxxxxxxxxxxxxxxxxxx@gmail.com
TOTAL EXPERIENCE 7 YEAR
PASSPORT NO xxxxxxxxxxxx
Notice time 2 Month

Declaration

Signature

S-ar putea să vă placă și