Ratings Guide
General Data.......................................................3
Abbreviations.................................................................... 3
Power Estimator..................................................4
For Top Irrigation System Efficiency ................................... 4
Determine Total Dynamic Pumping Head........................... 4
Centrifugal pump taking water from pond to
open discharge................................................................. 5
Preliminary Estimate.......................................................... 5
Final Calculation................................................................ 5
Deep well pump delivering to sprinkler system.................... 6
Calculate Power to Deliver Needed Water Flow.................. 6
Notes............................................................................... 7
Preliminary Estimate.......................................................... 7
Final Calculation................................................................ 7
404D-22...............................................................8
404D-22T.............................................................8
1104D-44T...........................................................9
1104D-44TA.........................................................9
1104D-E44TA....................................................10
1106D-E66TA....................................................11
Sales and Service Network...............................13
Canada.......................................................................... 13
USA............................................................................... 14
Central America and Caribbean....................................... 15
South America................................................................ 15
Perkins Irrigation Engine Ratings Guide
General Data
Photos are for illustrative purposes only and may not reflect final
specifications.
All rating conditions are based on ISO/TR 14396, inlet air standard
conditions with a total barometric pressure of 100 kPa (29.5 in. Hg),
with a vapor pressure of 1 kPa (0.295 in. Hg), and 25˚C (77˚F).
Performance measured using fuel to specification EPA 2D 89.330-
96 with a density of 0.845-0.850 kg/L @ 15˚C (59˚F) and fuel inlet
temperature 40˚C (104˚F). Applies to advertised gross intermittent
ratings.
Abbreviations
ATAAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air to Air Aftercooled
in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inches
EpaK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electropak
EU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . European Union
kg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Kilograms
mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Millimetres
T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Turbocharged
TBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . To be advised
Perkins Irrigation Engine Ratings Guide
Power Estimator
For Top Irrigation System Efficiency ...
This selection guide will help you identify your irrigation power needs
and choose the right Perkins engine to meet those needs efficiently.
High reliability and low cost of ownership make Perkins engine power
your most attractive option.
1. Static Head
Vertical distance pump must life water from pick-up point to
discharge.
Pick-up point is the draw-down water level in the well or the
surface of stream or pond from which water is pumped.
Discharge level, in the case of a pivot or travelling system, is height
of the sprinkler at highest pint in the field.
2. Pressure Head
For open discharge to pond or canal, pressure head = 0.
For sprinkler system a fair initial estimate is 415 kPa (60 psi).
Actual value varies from 275 kPa (40 [psi) for a low pressure
system to about 550 kPa (80 psi) for a high pressure system.
Multiply kPa x 0.102 to get meters pressure head (psi pressure x
2.31 = ft. pressure head).
3. Friction Head
Estimate 1 m (ft) friction head per 100 m (ft) pipe run from pick-up
point to start of sprinkler system or to open discharge. Actual
value based on pipe selection, bends, fittings.
4. Total Dynamic Pumping Head
Total of 1, 2 and 3.
Perkins Irrigation Engine Ratings Guide
Power Estimator
Centrifugal pump taking water from pond to open
discharge
_________________________ m _________________________ m
ft ft
_________________________ m _________________________m
ft ft
_________________________m _________________________m
ft ft
_________________________m _________________________m
ft ft
Perkins Irrigation Engine Ratings Guide
Power Estimator
Deep well pump delivering to sprinkler system
Perkins Irrigation Engine Ratings Guide
Power Estimator
Notes
_______________________ kW _______________________ kW
hp hp
__________________________ __________________________
__________________________ __________________________
_______________________ kW _______________________ kW
hp hp
_______________________ kW _______________________ kW
hp hp
_______________________ kW _______________________ kW
hp hp
_______________________ kW _______________________ kW
hp hp
Perkins Irrigation Engine Ratings Guide
404D-22 Power Unit
404D-22T
404D-22
Complies with EU Stage IIIB and EPA Tier 4 Interim for non-road
mobile machinery powered by variable speed engines (EPA 40 CFR
Part 1039 Tier 4)
Perkins Irrigation Engine Ratings Guide
1104D-44T Power Unit
1104D-44TA
1104D-44TA
Perkins Irrigation Engine Ratings Guide
1104D-E44TA Power Unit
1104D-44TA
10
Perkins Irrigation Engine Ratings Guide
1106D-E66TA Power Unit
1106D
11
Perkins Irrigation Engine Ratings Guide
12
Perkins Irrigation Engine Ratings Guide
Sales and Service Network
*Perkins products are available direct from a coast to coast distributor
network. Through Master Distributors who direct and support the
aftermarket activities of local dealers, you have easy access to Perkins
engines, parts and service. The most respected names select Perkins
for their power needs. Perkins: Designed to perform, delivered with
choice.
Canada
Diesel Distribution
389 Deerhurst Drive,
Units 3 & 4 Brampton
Ontario, L6T 5K3
(t): 905-799-1544
(f): 905-799-1577
888-549-4444 (Eastern
Ontario only)
www.dieseldistribution.
com
13
Perkins Irrigation Engine Ratings Guide
USA
14
Perkins Irrigation Engine Ratings Guide
Central America and South America
Caribbean
Diesel Santa Cruz
Mercantil Antillana C por A (t): 5913-346-3740
Avenida Maximo Gomez 174 (f): 5913-346-2413
PO Box 791
Distribuidora Perkins Chilena SAC
Santo Domingo
Av Colorado 641
Dominican Republic
Parque Industrial Aeropuerto
(t): 809-566-3141
Quilicura, Santiago, Chile
(f): 809-566-3144
(t): 562-620-3700
(f): 562-739-1818
Tecun
3a Calle 3-60 Zona 9 De La Sobera Hnos SAIC
Guatemala, CA 001009 Avda Eusebio Ayala,
(t): 502-334-6534 1947 Asuncion, Paraguay
(f): 502-334-6502 (t): 595-21-228529 / 595-21-202913
(f): 595-21-207272
Cemcol Comercial SA de CV
Km 5.5 Carretera a La Lima, Arfil SA
Calpules (t): 5982-924-2021 / 2044
San Pedro Sula, (f): 5982-924-2013
Honduras
(t): 504-559-5899 Industrias Ivor Ltda Casa Inglesa
(f): 504-559-7566 Carrera 61 # 45-14
Medellin, Colombia
H F Cross SA (t): 574-231-4245
Edificio Casa Cross (f): 574-511-0658
Calle 15 de Septiembre
Apartado Postal 1169 Mercantil Antillana C por A
Managua, Nicaragua Avenida Maximo Gomez 174
(t): 505-268-4693 PO Box 791
(f): 505-268-1262 Santo Domingo, Dominican Republic
(t): 809-566-3141
Expert Diesel SA (f): 809-566-3144
Zona Procesadora Panexport www.mercantil.ant@codetel.net.do
Col Ojo de Agua
Vallejo Araujo SA
Panamá, Zona 15, Panama
Av Carlos Julio Arosemena
(t): 507-273-8860
Km 1.5 PO Box 717
(f): 507-273-7807
Guayaquil, Ecuador
(t): 5934-220-0333
RIMCO Inc
(f): 5934-220-1651
John F Kennedy Avenue
KM 3.7, Road #2 Engineering and Construction Inc
San Juan (ECI)
Puerto Rico 00921 39-40 Friendship, East Bank
(t): 787-792-4300 Demerara , Guyana, LA
(f): 787-782-1044 (t): 592-225-3135
(f): 592-225-3267
Parts & Power Ltd www.ecinew@networksgy.com
Wickham’s Cay II
PO Box 850 Motores Diesel Andinos SA
Road Town, Tortola (Modasa)
British Virigin Islands Avenida Los Frutales 202
(t): 284-494-2830 Ate, Lima, Peru
(f): 284-494-6972 (t): 511-437-9642
(f): 511-437-9199
Tradewinds www.modasa.com.pe
5820 NW 84th Avenue
Miami, FL 33166 Crosland Tecnica SA
(t): 305-592-9745/800-223-3289 Avda Argentina 3250
(f): 305-592-2104 Callao, Peru
(t): 5114-51-5272
(f) : 5114-29-6001
15
Perkins Irrigation Engine Ratings Guide
Asia
Perkins Engines (Asia Pacific) Pte Ltd
14 Tractor Road
Singapore 627973
Telephone +65 6828 7469
Fax +65 6828 7414
North America
Perkins Engines Inc
N4 AC 6160
PO Box 610
Mossville, IL 61552-0610, USA
1-888-PERK-ENG
Telephone +1 309 578 7364
Fax +1 309 578 7329
Latin America
Perkins Motores do Brasil Ltda
Rua Alexandre Dumas, 1711 Ed. Birman 11, 9o andar
Chácara Santo Antonio
São Paulo / SP - Brasil
Cep: 04717-004
Telephone +55 11 2109 2038
Fax +55 11 2109 2089
www.perkins.com
All information in this document is substantially correct at time of printing and may be altered subsequently
Publication No.1949/08/09 produced in England ©Perkins Engines Company Limited 2009