Dekati ®
DEKATI Ltd.
Gravimetric Impactor Line Dekati Ltd. develops, manufactures and markets instrumentation needed
in fine particle measurement and sampling. In 1995, Dekati introduced the
world’s first real-time fine particle concentration and size distribution
measurement instrument. Since then, our R&D department has continually
® increased the range of products. Through the extensive global sales network,
Dekati Low Pressure Impactor we are able to serve our customers around the world.
DLPI ®

• Cascade impactor with robust, stainless steel construction


Dekati develops new products in close co-operation with the world’s leading
universities and companies. Our mission is to provide our customers with
innovative fine particle measurement solutions that guarantee accurate
Dekati
• Particle size distribution measurement
• Gravimetric or chemical analysis of the collected particles
results. Dekati instruments are used for example in the following application
areas:
Product Line
• Can be upgraded into ELPI instrument for real-time data
• Combustion Processes (Diesel, Gasoline, Oil, Coal, Bio-fuels etc.) Excellence in

Dekati is a registered trademark of Dekati Ltd.


• Environmental Ambient Aerosol Research and Monitoring



Pharmaceutical Drug Screening and Inhalator R&D
Nanotechnology
Material Processing
Particle Measurements
®
Dekati PM10 Impactor
Visit www.dekati.com for more details on our company and our products,
• PM10, PM2.5 and/or PM1.0 measurement or contact us at sales@dekati.fi for further information.
• Particle emission measurement according to ISO23210
• Air quality measurement
• Robust, stainless steel construction
ELPI+™
BOLAR™
®
Dekati® Mass Monitor DMM
Dekati Gravimetric
Dekati® Low Pressure Impactor DLPI
Impactor DGI
Dekati® PM10 Impactor
• Cascade impactor with simple construction
• Particle size distribution for <2.5 μm particles Dekati® Gravimetric Impactor DGI
• 47 mm collection filters
• High sample flow rate of 70 lpm
Dekati® Thermodenuder
Dekati® Diluter
Dekati Ltd.
Osuusmyllynkatu 13 FPS-4000
FIN-33700 Tampere
Finland
Tel. int. +358 3 3578 100
Dekati® Axial Diluter
Fax int. +358 3 3578 140
E-mail sales@dekati.fi Dekati® Engine Exhaust Diluter DEED
www.dekati.fi
Dekati® Cyclone

Pictorino Advertising 8/2012 Kirjapaino Hermes


For more information, please contact: sales@dekati.fi

Dekati Ltd. is specialized in the design and manufacture


of innovative fine particle measuring and sampling devices.
Since its founding in 1994, Dekati has become the techno-
logical market leader in producing fine particle measurement
instrumentation for various applications and thousands of Excellence in Particle Measurements
customers.
®
Dekati Product Line
Fine Particle Measurement Aerosol Dilution and Conditioning
Instruments Dekati® aerosol dilution and conditioning instruments enable particle sampling
from virtually any source. Customized Dekati® sample conditioning solutions are
available for special aerosol measurement needs.

® ®
ELPI+™ Dekati Diluter Dekati Axial Diluter
• Real time particle size • Ejector diluter for aerosol dilution
DAD
distribution measurement • Constant dilution ratio • Simple dilution system for
• Wide particle size • Robust, stainless steel construction particle measurement applications
measurement range
• Reliable, easy-to-use operation • Low consumption of dilution medium
• Possibility for chemical
• Heated dilution setups • Low particle losses
characterization of size
available, max 400 ºC
classified samples • Customized dilution ratio
• Real-time charge distribution
measurements
• Robust instrument with
wide range of applications ®
Dekati Thermodenuder
• VOC removal from exhaust gas
• Easy and reliable operation
®
Fine Particle Sampler • High sample flow rate
Dekati Bipolar FPS-4000 • Well characterised
Charge Analyzer • Two stage operation
versatile dilution system
BOLAR™ • Adjustable dilution ratio and
temperature
• Particle bipolar electric • Monitoring and control of dilution
charge measurement parameters
• Particle size classification • Heated dilution setup for combustion
• Charge to mass ratio aerosol conditioning
®
determination
• Designed for DPI, MDI and
Dekati Cyclone
nebulizer development
• Pre-separator for emission measurements
• Unique information for
inhaler development • Designed according to EPA 201A
• Stainless steel construction
• Operation up to 600 ºC

®
®
Dekati Mass Monitor Dekati Engine
DMM Exhaust Diluter
DEED
• Real-time vehicle emission
measurements • Sample conditioning
• Particle mass and according to Euro5b/PMP
number concentration • Guaranteed low particle losses
• Particle size information • Fixed dilution settings
• High sensitivity and large - unmatchable repeatability
dynamic range • Simple, plug-and-play operation
• Pre- and post-DPF • Accessories available for pre-
measurements and post-DPF sampling