Sunteți pe pagina 1din 8

Reference: Issue No.

HHP-016/14 1
Issue Date:
ECC F040 Original / Supersedes
Supplements / :
SEAG HHP Product Support 13/06/14
Service Centre Technical Tip Original
Compiled by: Approved by:
Title: HHP-016-14_SM-G900F Complete flash change process
Tóth Viktor / SEAG /
Barak Gábor Marijan Maric

Applicable
Models SM-G900F

Issue
Complete flash change process

Description
Fault detection:
Typical power consumption 140-170mA.
Try JTAG (use the following guide: (14-32) SM-G900F Boot Recovery Guide_rev2 0
from the GSPN), if the following message shows up, the Flash IC (UME6000) faulty, it’s
need to be changed.

Part details:
Position: UME6000
Name: IC-FLASH MEMORY
Sec Code: 1107-002239

For more information view the latest User or Service manuals on GSPN.
If you have any questions please raise them via the Subsidiary Technical Support

Page 1 of 8
Flash Change:

Flash Position:

Martin Desoldering heat profile:

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 2 of 8
Martin Soldering heat profile:

When it’s done, try JTAG again.

Reactivation Lock:
Download the Full SW on the phone.
In order to unlock the reactivation lock follow the “(14-49) GalaxyS5 How to skip box
open Reactivation Lock activation.pdf” notice.

In a few words:
1.: Download a full SW over version ND2 on the phone
(Not every SW even if it is over ND2 can unlock the reactivation lock at this state, so if it
doesn’t work, use different SW or SW with different buyer. There is a list in the referred
notice)
2.: Download the EFS

It should be ok now.

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 3 of 8
RF Calibration:
1.: Download the newest production SW on the phone.

2.: Use the CmdChkTool V1.4_0820 to avoid the SMD function process omission fail
during calibration:

Note: The phone has to be powered by the Anyway JIG, and it has to be booted completely.

2.1.: Set the port and the protocol (AT CMD)


2.2.: Open the port
2.3.: Set the “SMD Function” item “P” on the Test NV sheet (12.).
2.4.: Write in the phone
2.5.: Set the “PBA Test” item “P” on the Test NV sheet(12.).
2.6.: Write in the phone

The OK message will appear if the write was successful.

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 4 of 8
Now in order to avoid all of the rest omission fails, test everything in the SEMI menu:

Sample of omission fail:

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 5 of 8
The battery have to be charged or:

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 6 of 8
Test parts:

1: Put an SD card in the phone and click


2: Put a SIM card in the phone and click
3: Test with an Earphone
4: Test it
5: Test it
6: Test it, IMPORTANT! Cover the HRM sensor receiver part. ONLY the receiver part:

Or the test will fail:

7: Test it
8: Test it
9: Test it
10: Test it
11: Test it
12: Test it

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 7 of 8
Now calibrate the phone:

Use the following versions:

IMEI Write:
Download the USER SW back, and write the IMEI.

Thanks to which provide us this Tech. Tip.

For more information view the latest User or Service manuals on GSPN. If you have any questions please
raise them via the Subsidiary Technical Support

Page 8 of 8

S-ar putea să vă placă și