Documente Academic
Documente Profesional
Documente Cultură
1. The TBL
2. BMS
3. Types of Maintenance
4. Responsibilities of Facilities Department
5. Tools
6. Certification
7. Accessibility
8. Staff structure
Kristina Gorchakovskaya BBA4
Triple Bottom Line (TBL): focuses on 3 pillars:
Single Bottom Line - Industrial revolution-> single bottom line-> important only the money you make
(as much money you have, as much happiness you have)-> society based on the individuality and competition)
We have to produce the circular processes – a situation with 0% production. Waste must be produced in a way that the outside of the planet be able
destroy in a way it can be reused/recycled
Bottom Line of success in the industry is Economy. We are not successful until we reach all the 3 P’s or E’s.
The triple Bottom Line: An accounting framework/ business philosophy with 3 parts.
Functions:
~ control system
~ program
conditions
~ monitor
consumptions
Components; BUS
BUS – the central wire that gathers information and sends it to monitors/ control centers and through which
information travels throughout the whole hotel until it reaches activators.
The sensors detect the physical activities (temp), send info though the bus which leads to BMS, which then sends
info to the actuators to the specific equipment.
Components Functions
Kristina Gorchakovskaya BBA4
Categories/Types of Maintenance
a. Run to failure (lamps)
Wait for the problem to happen before fixing, savings in short term, huge problems in long term; let it function till
it fails and then replace it. (Not so recommended because it can be more expensive).
b. Time based (scheduled)
Pre-determined schedule for everything “classical”; preventive. We schedule what to check throughout the year.
Save a lot of money, but not the best.
c. Condition Based (TB+BMS)
Software-monitor: Use of computers to check equipment’s conditions. Saves costs on long term. maintaining some
conditions (air fluidity, temperatures, humidity) provides good conditions, and saving energy (help of the bms system)
d. Reliability-centered maintenance (TB +BMS +EMP)
Incorporates the other 3 à evaluate and choose appropriate one (The one with less cost & the most economical
& ecological). strategy with a goal based in saving -> environmental management program that establishes the goals to
save energy (mix the other 3; save money/water/ energy-> being green)
Accessibility:
Must be accessible for handicapped people/ Compulsory to design some special places that must be designed for disable people
(front desk, ramps, bedrooms, toilets, sound messages, parking)
a. Places
I. Parking: closer parking ramps
II. Sidewalk: large space
III. Front Desk: lowered desk
IV. Restroom: full mirror, out swinging door, bar to hold on, knee room
V. Restaurant: accessible door width, spaced seating
VI. Room: TV w/ remote, space around furniture, accessible height for electronic control
VII. Stairways: handles + contrasting color or texture for top and end
VIII. Step free access to main entrance; Lower hanging space in closets; Elevator to ground floor; Automatic door
opening; Rolling shower; Bars in the bathroom; Raised toilets; Level or ramp to public áreas ;Sound messages
5. Training the staff in order to save waste - continued education and training is essential to orient new employees and
enable veterans to learn emerging and changing technologies
7. System & Building design - ensure that the facility has been designed with maintenance and operating costs in
maintenance and operating costs in mind (manager should have knowledge as possible about the systems and
components of the building
8. Special projects - unexpected tasks that fall to staff and that meet unique demands and needs from the guest
9. Waste management - regulate the activities in a way to reduce operation’s environmental impact
10. Inventory control - specialized parts and equipment needed for facilities operations requires the inventory be adequately
controlled in order to prevent theft + ensure that parts and materials are available when needed
11. Emergency plan - staff plays leadership roles in property level emergency planning and response teams
12. Budgeting / Cost control - must be able to plan and budget their financial needs + control the expenditures in all
areas under their preview
14. Systems and building commissioning- process for achieving, verifying and documenting the performance of each
system to meet the operational needs of the building (TAB- testing- adjusting and balancing)
15. Building and system operations- day-to-day activities that ensure the building and its systems continue to operate
as intended and provide needed services
16. Building maintenance- Building structure serve as first line of protection for the building’s occupants and contents,
so they must be attended to the building needs (building’s exterior is the first image that guests get exposed to)
17. Equipment maintenance and repair- vast and varied amount of equipment whose proper operation requires maintenance and
repair needs to be done + maintenance and repair of equipment used in or by other departments
18. Utilities management- staff & management should be able to choose the best options in order to obtain the best sustainable
and environmental use
19. Corporate reporting- documenting the activities of the facilities department is important to the success of the operation ->
they need to gather and report specific additional information on facility maintenance, repair and restoration and on
compliance with internal and governmental requirements-> they will serve to record system and facility failure + repair
and restoration guides for future reference in similar circumstances
Elevation plan- representation of a vertical plan; detail perspective; 3D; building taken from a head-on perspective and
drawn to scale
Technical /mechanical Plans- layout of an engineering system (ventilation; sanitary); plumbing fixtures and water flow+
HVAC+ ductwor
v Benchmarks: used by chef engineering to manage facilities. Compare with past results of: usage,
efficiency, staffing level.
§ Benchmarking is one way for business owners and management to evaluate internal
policies and do comparisons with competitors and other companies.
§ Examples: P.O.M utilities, Program C.M.M.S., etc…
EMP Water
EMS Energy
EMAS Waste
v Forms: room data form, schedules, operating procedures, energy records…
They give us precise/ technical conditions of the specific machine/machine. A registry for the work being
done. (Room date form). organizes the actions (standardizing the actions)-> manuals take care of machines;
piece of paper concerning the maintenance of the hotel; work order-communications system that makes the
facility department aware of the problems so that action can be taken to rectify the situation in a timely
manner
Kristina Gorchakovskaya BBA4
Certifications:
Hotels wants to say to people that we are green, so they can sell- obtain the trust of people- green hotels should have some
certifications in order to gain trust
Types
Process
I. TESTING: 3rd Party comes to hotel with criteria and check if you follow standards à Scientific Analysis
II. VALIDATING: record keeping process à certification or not/
III. AUDITING: follow-up inspection to keep or remove certification
Names
Kristina Gorchakovskaya BBA4
Staff Structure:
a. 3 employees / 100 rooms
b. Depend on the status of the hotel (luxury, mid-level, low)
c. Engineering Manager à In charge of utilities, maintenance & repair. Swing shift.
d. Always consider the size of the hotel and surrounding garden areas.
e. Organization of the department is predicated on the size of the facility
f. Employees in the facilities department are either specialists or generalists.
g. Larger properties tend to have far more specialists, and the smaller hotels will tend toward fewer
specialists and more generalists.
• Employees of the department may include but are not limited to:
– Secretaries/Dispatchers -Electricians -Plumbers
– Carpenters -Refrigeration Technicians -Boiler Operators
– Elevator Technicians -Automotive Mechanic -Computer Technicians
– Painters -Landscaping and Grounds Personnel
– Fire Control and Security Systems Specialists
Facilities department-> engineer (boss/manager) that knows how everything works + 3 people for each 100 rooms
(normally; in small properties they know a little bi of everything, and they are multitasked, but in big properties they are
more specialized, and can even outsource some features because of its complexity)
EMERGENCY PLAN:
-specifies the hotel organization, location of staff & guests
-nearest located hospital
-locator of fire brigade,
-stair location (emergency route)
-procedures of different types of emergency
Components:
1. Hazard recognition, evaluation and control
2. Workplace design and Engineering (make facilities safer)
3. Safety Performance Management (standards)
4. Regulatory Compliance Management (agencies regulations)
5. Occupational Health (first aid programs)
6. Information collection (safety and health activities à inspections, record)
7. Employee Involvement (people more important than machines)
8. Motivation, behaviour and attitudes
9. Training and Orientation
10. Organizational Communications
11. Management and control of external exposures (risks beyond organization walls)
12. Environmental Management
13. Workplace Planning and Staffing
14. Assessments, audits and evaluations (evaluate to meet needs of the org.)
è Pool:
o Normal water quality (what our guests expect)
o Make sure right chemical balance
o Lifeguards
o Pool markings (measures)
o Fencing
o Pool safety equipment
o Proper disposal of hazardous chemicals
o Measure ph. of the water regularly; check the quality of the water and if there is a need to implement
chemicals to kill bacteria’s.
è Quality of the water- keep water quality audit in order to detect microbes and bacteria; warn the staff of the
hazardous materials (grease, paint, cleaning materials), so they can be careful about it; warn the guests if the
water is or not potable; be sure the tanks are properly cleaned and checked
è Fire evacuation- do fire simulations regularly and be sure that everyone in the team knows what to do in this
cases; be aware of the expiry dates of the fire extinguishers; do plans of evacuation and establish them
è Indoor air quality- check the filters regularly; do air evaluations from time to time
è Evacuation plan
To guide the guest to go out from the building, the Exit signs and lightning in a fire is really important. The management
system has to keep the exit signs illuminated and clear of obstruction. The light need to be installed before and should be
working every time. Fire and smoke control doors should not be kept open, in order not to compromise the fire protection.
Evacuation plan is important, as emergencies are probable in hotels. The plan should include- all the members of the staff
need to supervise the guests movement to guarantee the evacuation and satisfy the special needs of some (handicap);
è Security systems
o Close Circuit TV Systems (CCTV) – can never be located in private places
o Lighting in parking lots and public areas
o Communication systems
o Landscaping – fences
o Elevators with cards or codes
o Locks on exterior gates/doors
Kristina Gorchakovskaya BBA4
Engineering system:
Fire system
A hotel is a machine.
3 groups of different fire systems:
Fire detection & alarm system Fire extinction systems Fire control systems (5)
Notify & detect fire System that extinguishes fire System that retain fire
ü Smoke & Heat detectors must be placed where there are a high
circulation of people.
ü The best option is connect the detectors to EPG/UPS.
Components:
v Heat Detector: only turns on when the temperature in the room increases radically and suddenly.
Detector placement and spacing are determined by manufacturer’s recommendations, engineering surveys and
laboratory tests.
In general there is one detector per room/hall.
v Smoke Detector: most frequently used because provide early warning and most hotel fires are detected by
this one.
Types: photoelectric and ionization (dirty air goes into a tube turning the detector on)
v Fire/Flame Detector : limited application. Used in storage areas but don’t detect a high degree of smoke
such as chemicals and paints.
v Alarm strobes: can be automatic or manual
v Wires
v Actuators & BUS - (Visual alerts, sound messages, alarms).
v Sound messages
EXTINGUISHED WITH
è Water
Special chemicals:
Liquid, powder or
foam
Fire Extinguisher System (active) – Sprinkler + Hose system (water pipe system) – fire extinguished with
fire that is extinguished with water
chemicals
need 2-3 people, “pass” word (pull, aim,
squeeze, sweep); you must take into The sprinkler system is the most common used in hotels for extinguish fires of type A, u
account the type of fire in order to water as extinguisher.
know which extinguisher to use. If
It is a system that is activated automatically.
extinguishers can´t put out fire then
switch off electricity at main panel and When this extinction system is activated, the water is pumped up from the
then use hose/sprinkler system tank and then is delivered by the pipes to the sprinklers, which are situated
among the guest’s areas of the hotel. These sprinklers spread the water
received in order to extinguish the fire.
COMPONENTS:
• Sectorization (construction system): Divide the hotel in many different areas/sectors in order to be able to
isolate the fire into one sector, maintaining the others out of the fire. This division is done taking into account
the emergency exits and the automatic closing doors.
RF -90- resistant to the fire 90 mins
• Fire Rating (RF; construction system): How long it takes for an object to be completely burnt.
Sectors are divided by metal fire resistant doors (RF-60) & floors (RF-120). Fire resistant doors are held by
magnets (actuators).
• Fire/Smoke Dampers: dumpers/cannels installed in ventilation systems à doors closes in order fire cannot
escape (E.g. Chimneys). Doors inside metal electrical ducts(ventilation holes in the whole building) are called
dampers. The wire receives a message from control center and activates the fire dampers and closes the
ducts.
• Pressurization system (engineering system): Found in biggest vertical shats. Fire & system alarms
activates pressurization that pushes air from the street into the building. Blowing and pushing fire away from
the shaft. Connected with alarm. E.g. fan in emergency exit.
• Automatic door closers – magnets which held the door and activate during fire
• Evacuation plan
To guide the guest to go out from the building, the Exit signs and lightning in a fire is really important. The management
system has to keep the exit signs illuminated and clear of obstruction. The light need to be installed before and should be
working every time. Fire and smoke control doors should not be kept open, in order not to compromise the fire protection.
Evacuation plan is important, as emergencies are probable in hotels
The plan should include- all the members of the staff need to supervise the guests movement to guarantee the evacuation
and satisfy the special needs of some (handicap);
To take the electricity from the city, we need to have a transformer that converts the high voltage electricity to low
voltage to use it in the hotel.
Once it is converted it goes through the wires to a main Panel / distribution Panel, where there are circuit breakers
(switch) that distribute the electricity in electrical Lines to each place of the hotel.
COMPONENTS
Main / Distribution Panel: it has many circuit breakers (switches) which distribute energy to the building/ many
departments of the hotel. Each switch is the beginning of an electric line
Subpanel: at the end of electrical wires until arrive to machine. Usually 1 per floor, distribute electricity.
Electrical fixtures – final users of electricity, sockets, artificial lighting, mini fridge
Counter – an electronic device, which is connected to BMS, controls consumption of electricity.
a. Emergency Power Generator (EPG) (diesel powered): Creates own electricity. Used for electricity by
burning fuel and should be big enough to run the building for hours
*Door Locks *Elevators in many floors *Emergency Fire Pumps *Front Desk
*Fridges *Emergency lights
c. Ground floor circuit interrupts (GFCI): Special sockets in a wet room or water pipe.
Turns off electrical current locally in the place very fast. WET ROOMS
Types of lighting:
1) General – we want our spaces to be lighted through homogeneous lighting (all same intensity),
cleaning purposes. It has a wide angle.
2) Task lighting – it has a narrow angle, more focused on certain tasks. (wardrobe, bathroom, reading
light)
3) Accent lighting – for improving and enhancing atmospheres. For art, décor.
2) Electrical Discharge – lamps that limit light in a different way. They are much more efficient. They can
transmit different colours.
A. Fluorescent LT5 / LT8: Tubes. Low CRI. Efficient white light for working places, kitche,
classes)
B. CFL (Compact Fluorescent Lamps): More efficient. Nicer warmer colour, cheap. 70-75% efficiency.
C. Metal Halide: Powerful. High CRI & efficiency. Replace Halogen with metal halide. Used in stadiums.
D. Sodium Vapor: very long lasting. Color yellow / orange. Back of the house / highways/ outdoor
parking.
3)LED’s (Light emitting Diodes) – completely electronic, can overlight the space.
è MOST EFFICIENT. 95% becomes light.
è Could save up to 80% of energy worldwide
è Long life
è Can be used in every single area of the hotel (F&B outlets, swimming pool illumination, reception, room’s
illumination…)
è LED’s creates a nice ambiance
è Due to they are electronic, they could be incorporated in control system. (BMS). Used to create different
atmosphere.
è Easily dimmable (regulate level of light)
IAQ:
Indoor Air Quality à through heating, cooling and ventilating we can change:
Wherever we are cooling we should humidify the air. Cooling dries the air. In cooling we are absorbing the air, sending
it to a heat exchanger, where heat is absorbed and the vapor condenses inside the liquid, thus the cool dry air is sent out.
Heat transfer types: Adding heat for heating; extracting heat for cooling
-Conduction; radiator pipes are heated by boiling water which is produced by a boiler
-Convention; in a hair-dryer, when current air passes through an electric resistor, it gets heated, heating the air around it.
Outside air is extracted and is passed through the electrical resistor sending heat air out.
Compressor Pump; pumps fluid in the closed circuit of pipe. The fluid we used in the circuit is called refrigerant, its easily
compressible to liquid and expands to gas easily.
Whenever we compress fluid it becomes hotter. Compressing-> Heats; Expansion -> Cools
A refrigeration cycle can heat & cool. If you switch the outside & inside system it can heat.
Explanation: the refrigerant goes to the expansion device, the refrigerant becomes cold, the cold refrigerant travels to the coil,
coil allows heat to enter, the air around coil gets colder and there is absorbtion (not air) of heat, the air is then blown to the
room by a fan.
The refrigerant becomes hot after absorbing heat, goes to the compressor pump when it becomes hotter and then goes to
the coil, the heat is then release when travelling in the coil, the air around it gets hot and then the hot air is blown by a fan
by convection.
I. Decentralized Heating: done in different areas of the building. Not efficient. One space- One Machine. Advanatges: if one
machine is broken, you just have to replace 1
Electric Heater
Electric current à resistor à electrical energy into heat energy.
NOT EFFICIENT, use too much energy
E.g.: Radiator, radiant floor, correctors
Used as portable & backup 40%
Machines only heat using electricity
“NEW”Heat pumps
Heats and cools use refrigeration cycle
Package Unit
Big machine on rooftop
Air Handling Unit = Decentralized + centralized (It is an integration of systems. Skyscrapers - it heats and cold)
Heat Pump - A box located on roof, heats using hot water pipe, cools using refrigeration cycle which requires boiler, chiller, pipes,
fan coil
COMPONENTS
Components Operation
Fans To send the air through the ducts
Ducts (metal, fiberglass Used to conduct the air
and to isolate: Rockwood)
Grilles & Diffusers Grilles are for return air
Diffusers are just for supply
Filters Responsible for the air cleanliness
Humidifiers Water that is in the air condenses in the Fan Coil, so we collect it at the
bottom with a pipe that goes to the sanitary system
Ventilation System
Cross ventilation: Leaving doors & windows 1. Treated Air Ventilation System (same air, not full of
oxygen): -linked to a centralized HVAC
open in order to circulate the water
Ducts
COMPONENTSà Filters
Humidifiers
Venturi effect: Courtyard effect. Chimneys. Hot Grills
air comes to cold place. Hot air goes up and cold air Diffusers
goes down
2. Air renewal ventilation system:
Mechanical ventilation system: only ducts and
Mechanical system to renew the air in crowded spaces.
insulation materials
Extracting air and another is blowing air.
Moves the air from inside to outside, and from outside to inside;
HOOD- absorbs all the air from the kitchen and from bistro-
other system with the fan, that blows the air from outside and
puts it inside
Takes out the bad smell and humidity from the bathrooms
7 COMPONENTS
1. Tank:
a. Keeps the water
2. Filter:
a. Softens the water (clean but takes away minerals) ! mixing it with salt // adding chlorine
b. Water has to be transparent, taste, color…
3. Pump:
a. Provides pressure to water ! enough to distribute it among the hotel.
4. Pipes:
a. Horizontal and vertical ! deliver water
b. Made out of ecologic plastics
5. Valves:
a. Keys to open and close
b. If building is very tall, you need pressure reducing valves (all bathrooms must have the same
one)
6. Counter:
a. Connected to BMS
7. Fixture:
a. Final uses of water. E.g. sprinklers, taps, etc.
Kristina Gorchakovskaya BBA4
FACILITIES FINAL EXAM BBA4
2. Hot Water Supply System (cold water + energy) 7 COMPO.
The process of distribution the water is the same as the cold water system. The only difference is that in hot
water system is that we need the boiler to heat the water before the pipes distribute it.
7 COMPONENTS
i. Tank
ii. Filter
i. Pump
ii. Pipes (isolated so they don’t lose heat)
iii. Valves
iv. Fixtures
v. Boiler ! to heat water
2. “Indirect” Boiler ! needs diesel or gas that are burnt to produce heat. We need another pipe that
returns unused water to the system because it’s always heating water. The most usual ones
Fire-Tube Boiler: Here the water arrives to the Water Tube Boiler: cold water in tube, fire in tank
boiler and in the metal tube that is inside we burnt
the diesel/gas so the water goes out hot.
Kristina Gorchakovskaya BBA4
FACILITIES FINAL EXAM BBA4
Kristina Gorchakovskaya BBA4
FACILITIES FINAL EXAM BBA4
3. Grey Water Sanitary System 5 COMP.
All water that has been used in a building, except the one from toilets.
Recycled water from sinks, laundry, showers/ tubs. The water is filtered and minimally sanitized and is then
suitable for use in a variety of non-potable applications. (E.g.: gardens)
5 COMPONENTS
i. Syphon: after each WC, a V shaped pipe that prevents hot air to escape
Kristina Gorchakovskaya BBA4
FACILITIES FINAL EXAM BBA4
Kristina Gorchakovskaya BBA4
Chapter 11: Vertical Transportation:
2 types:
2 cilinders inside the elevator pit Cab attached to the machine through ropes
Clappers- electronic device that holds the
Pulley- moved by a motor (traction machine)
cylinder-extra safety
linked to the machine-
Machine room- tank full of fluid and we push
it inside the piston (to go up) Controller (stops and levels it)
Pump- pushes again the fluid to the tank –
passenger safety Governor- stops the cab when it senses extra speed
Controller- controls velocity when it is going to Counterweight
stop
Manual wheel- whenever there is no electricity
and people is inside you can move the cab-
extra safety
Components: Components:
elevator cab, controller room on top,
piston, ropes,
pump, elevator cab,
tank, pulley
2 cylinder, counterweight,
door equipment, elevator pit,
clappers buffers,
controller governor
+ Components
Kristina Gorchakovskaya BBA4
ENERGY
Rooms à key card system - turns off the light when guest is not in.
- Light on/off
- Occupancy sensor
- Limit temperature ranges in thermostats
- Use thermostats
Water Heating:
- Isolation of pipes
- Solar thermal panel + indirect boiler
- Instantaneous heaters
- No loss of energy
- Don’t overheat water (60ºC is ok)
- Well insulated pipes
- Use heat recovery system or solar energy.
H.V.A.C:
- Training on EMP
- Job Description
- Part of the company philosophy
Guest Participation Program:
- Solar Panels
- Replace old machines for new and efficient ones.
Lighting
Bins in rooms
Environmental club
Implement structured waste minimisation and recycling programmes in participating hotels
HSK staff can help saving energy by resetting thermostats when they are done cleaning a room,
closing drapes, reporting water leaks, and turning off lights; Staff should be trained in the way they
should know how the environmental management program can help to not waste resources;
Kristina Gorchakovskaya BBA4
Toilets:
Kitchen / Restaurant:
- Light detectors
- Defreeze frozen food in advance
- Peddle activities taps
- Upgrade machinery to energy star qualifies
- Fully load the dishwashers
- Use pedal taps in kitchen
- Use efficient machinery
- Fix leaks and drips
- Use a half filled sink of water for dishwashing
- Cool food in all natural, no water use
Pool / Spa:
Garden:
- Linen control
- Amenities in dispensers
- Part of company philosophy
- Training induction
- For guest: reuse towels and bed linen
- For staff: close tap when is not used (F&B, housekeeping).
- Train laundry staff to maximize efficiency.