Clean Air Conditioners

Clean air conditioners suitable for hospitals

BEBAS CFC DAN HCFC


Easily providing the high cleanliness
environment required by various industries.
Daikin’s clean air conditioners are specially designed to realize an environment of cleanness class 10,000 with little
construction.
These air conditioners easily realize a cleanliness-class environment and help create the atmospheric environment
of hospitals, food and beverage factories, electronics factories and other venues that require clean air.

Select the air flow system and installation method to match the usage
environment and purpose of the room.
Two types of clean air conditioner are available – an integrated outlet unit model and a separate outlet unit model.
Furthermore, it is possible to configure the air flow system to ceiling intake or floor-level intake according to the panel selected.
This makes it possible to respond precisely to the layout and purpose of the room.

Model series
Integrated outlet unit model

Ceiling intake type

FBXYP45MA (Corresponding to 1.6HP) FBXYP56MA (Corresponding to 2HP) FBXYP71MA (Corresponding to 2.5HP)


Decorative panel · · · · · · · · · · ·BYBP82D56C Decorative panel · · · · · · · · · · ·BYBP82D56C Decorative panel · · · · · · · · · · ·BYBP82D80C
Standard HEPA filter · · · · · · · ·BAFHJ82A56 Standard HEPA filter · · · · · · · ·BAFHJ82A56 Standard HEPA filter · · · · · · · ·BAFHJ82A80
[Quick navi] operation [Quick navi] operation [Quick navi] operation
remote controller · · · · · · · · · · ·BRC1E62 remote controller · · · · · · · · · · ·BRC1E62 remote controller · · · · · · · · · · ·BRC1E62

Floor-level intake type

FBXYP45MA (Corresponding to 1.6HP) FBXYP56MA (Corresponding to 2HP) FBXYP71MA (Corresponding to 2.5HP)


Decorative panel · · · · · · · · · · ·BYBP82D56W Decorative panel · · · · · · · · · · ·BYBP82D56W Decorative panel · · · · · · · · · · ·BYBP82D80W
Standard HEPA filter · · · · · · · ·BAFHJ82A56 Standard HEPA filter · · · · · · · ·BAFHJ82A56 Standard HEPA filter · · · · · · · ·BAFHJ82A80
[Quick navi] operation [Quick navi] operation [Quick navi] operation
remote controller · · · · · · · · · · ·BRC1E62 remote controller · · · · · · · · · · ·BRC1E62 remote controller · · · · · · · · · · ·BRC1E62

Separate outlet unit model

Ceiling intake type Floor-level intake type


FBXYP71MAP (Corresponding to 2.5HP) FBXYP71MAP (Corresponding to 2.5HP)
Decorative panel · · · · · · · · · · ·BYBP82D80CP Decorative panel · · · · · · · · · · ·BYBP82D80WP
Outlet unit · · · · · · · · · · · · · · · · ·BAFJ82B80 Outlet unit · · · · · · · · · · · · · · · · ·BAFJ82B80
Standard HEPA filter · · · · · · · ·BAFHJ82A80 Standard HEPA filter · · · · · · · ·BAFHJ82A80
[Quick navi] operation [Quick navi] operation
remote controller · · · · · · · · · · ·BRC1E62 remote controller · · · · · · · · · · ·BRC1E62

1
Instances of installation by type (for a hospital)
Type Ceiling intake type Floor-level intake type
(high speed contracted flow/high ceiling model) (gentle wind distribution/high cleanness class model)
Construction work is simple and a ceiling installation is Easy to increase the cleanness and air-conditioning effect.
Features possible. A low flow speed prevents drying of the affected part and
Dust filtering and air-conditioning can be started immediately. the experience of drafts.

Cleanness class*1 100,000 to 10,000 10,000

Wind speed 1.0m/s or higher 0.5m/s


Concentrated air conditioning centered directly under Total air conditioning with an emphasis on cleanliness.
the unit.
Easy installation.

Integrated Intake
outlet unit (sourced locally)
model

Applications: Surgery prep rooms, recovery rooms, nurse stations, etc Applications: Operating theatres, delivery rooms, etc
Blow
method Somewhat concentrated air conditioning centered Total air conditioning with an emphasis on cleanliness.
directly under the outlet. Maintenance from a different room possible.
Can air-condition irregularly shaped rooms.

Separate Outlet Air


outlet unit unit conditioner
Intake
model (sourced locally)

Applications: CCU*2, sterile rooms, etc Applications: Premature nurseries, newborn nurseries, ICU*3, etc

*1. Cleanliness class. A scale expressing the cleanliness of air established by NASA (National Aeronautics and Space Administration). Class 10,000 represents a state of less than 10,000 minute
particles of diameter under 0.5 µm per cubic foot.
For comparison, the cleanliness of a typical office is around class 1,000,000.
*2. CCU (Cardiac Care Unit). A ward dedicated to the admission of patients with myocardial infarctions and other heart diseases.
*3. ICU (Intensive Care Unit). A ward for the careful treatment and nursing of patients with serious illnesses, injuries, or recovering from operations.

Can be easily installed The floor-level intake system prevents uncomfortable


in existing buildings. drafts with a low flow speed of 0.5 m/s.
A simple structure makes it easy to realize The floor-level intake system has a low Air flow distribution diagram
a highly clean environment with the same flow speed of 0.5 m/s, improving dust (operating theatre)
(m3/sec)
installation work as for a typical air filtration and eliminating the feeling of 3m
Outlet
0.6
conditioner. Can be easily installed in new drafts. Broadly air-conditions the room 0.5
buildings, existing structures, and during with a gentle air flow and creates a 0.4
refurbishments. people-friendly environment. 0.3
0.2
Intake
0.1
0 0
*Analysis of the floor-level intake type 3m 0 Operating Intake 3m
with the integrated outlet model. table

The ceiling intake type provides concentrated air conditioning Please make sure to use the floor-level intake type in
centered directly under the outlet. Accordingly, please be aware of the following kinds of locations.
the following. • Locations in which heating of the lower part or the entire room is
• Sufficient heating my not be achieved near the floor or at locations far from the outlet. important.
• In the case of utilization in a hospital, some patients may be susceptible to cool • Locations necessitating a particularly high cleanliness factor and
Attention drafts, so please ensure that they do not come directly under the outlet. in which there are a lot of people.

2
Providing
Providing eacheach
andand every
every necessary
necessary
function
function at at a high
a high standard.
standard.

Clean
Clean
Realizing
Realizing cleanliness
cleanliness classwith
class 10,000 10,000 withfilter
an HEPA an HEPA filter
(sold
(sold separately).
separately).
The low
Thepressure-loss
low pressure-loss
standard
standard
HEPAHEPAfilter filter
(sold(sold
separately)
separately) Standard
Standard
HEPAHEPA
filter filter
demonstrates
demonstrates
a superior
a superior
dust dust
filtering
filtering
performance
performance
and easily
and easily
accomplishes
accomplishes
an airan
cleanliness
air cleanliness
of class
of class
10,000.10,000.

The HEPA
The HEPAfilter filter
has ahas
structure
a structure
incorporating
incorporating
a pleated
a pleated
glassglass
fiber fiber
filter filter
medium,medium,
making
making
it highly
it highly
efficient
efficient
and suitable
and suitable
for for
cleanclean
rooms rooms
etc. etc.

* It may not
* It be
maypossible
not be possible
to maintain
to maintain
cleanliness
cleanliness
in roomsinwith
rooms
low with
air tightness.
low air tightness.
* An antibacterial
* An antibacterial
HEPA filter
HEPA
(order
filter
item)
(order
which
item)
inhibits
whichthe
inhibits
propagation
the propagation
of filteredofbacteria
filtered bacteria
is also available.
is also available.
Cannot be Cannot
used with
be used
the standard
with the standard
HEPA filter.
HEPA filter.

Antibacterial
Antibacterial
Suppresses
Suppresses the propagation
the propagation of in
of bacteria bacteria
the duct in the duct
with
with a proprietary
a proprietary mixed mixed antibacterial
antibacterial powder coating.
powder coating.
The filter
The filter
implements
implements
an antibacterial
an antibacterial
treatment
treatment
with awith
newa coating
new coating
combining
combining
a silver-based
a silver-based
inorganic
inorganic
antibacterial
antibacterial
material
material
effective
effective
against
against
germsgerms
and anandorganic
an organic
antibacterial
antibacterial
material
material
that prevents mold.mold.
that prevents
This enhances the antibacterial
This enhances condition
the antibacterial of theofduct.
condition the duct.

Antibacterial
Antibacterial fiberinused
fiber used in thefilter.
the intake intake filter.
An An antibacterial
antibacterial type istype
also is also
used forused for filter.
the HEPA the HEPA filter.
With With
a long-life
a long-life
filter filter
employing
employing
mold-preventing
mold-preventing antibacterial
antibacterial Structural
Structural
diagram
diagram
Fan Fan
fiber fiber
near near
the intake,
the intake,
cleaning
cleaning
performance
performance
is increased
is increased
even even
further.
further. An antibacterial
An antibacterial type type
(order(order
item)item)
mademadefrom from
a a
Intake Intake
filter filter
combination
combination of antibacterial
of antibacterial fibersfibers that suppress
that suppress the the (antibacterial
(antibacterial
fiber) fiber)
propagation
propagation of collected
of collected bacteria
bacteria is available.
is also also available.

* Please be* Please


awarebethat
aware
antibacterial
that antibacterial
productsproducts
suppresssuppress
the propagation
the propagation
of bacteriaof bacteria
but do notbuthave
do not
a have a
sterilizingsterilizing
effect. Also,
effect.
mold
Also,
may mold
growmayin places
grow inwhere
placesdust
where
or soot
dustaccumulates.
or soot accumulates. Outlet Outlet
panel panel HEPAorfilterSheet
HEPA filter or steel
Sheet steel Intake Intake
panel panel
* A material
* A for
material
whichforthewhich
registered
the registered
safety wassafety
verified
wasbyverified
Japanese
by Japanese
chemicals chemicals
and dangerous
and dangerous
substancessubstances
(punched)
(punched)
antibacterial drain pan
antibacterial drain pan (punched)
(punched)
regulation regulation
law (Act on
lawthe
(Act
Evaluation
on the Evaluation
of Chemical
of Chemical
Substances
Substances
and Regulation
and Regulation
of Their Manufacture,
of Their Manufacture,
etc) is etc) is
used for used
the antibacterial
for the antibacterial
material.material. HEPA filter(antibacterial
HEPA filter (antibacterial
treated)
treated)
* Please make
* Please
sure
make
to carry
sure out
to carry
maintenance
out maintenance
periodically
periodically
(cleaning(cleaning
the air filter
theand
air filter
washing
and washing
the insidethe
of inside of (order (order
item) item)
the unit).the unit).

3
Installation
Installation
example example
(in a hospital
(in a hospital
facility)facility)

Quiet
Quiet
AllAll models
models incorporateananindustry-leading
incorporate industry-leadingmeticulous
meticulous
quiet
quiet design,
design, operatingatatunder
operating under41dB.
41dB.
Operating
Operating
noisenoise
is substantially
is substantially
reduced reduced
by employing
by employing
a a
proprietary
proprietary
double-structure
double-structure
outletoutlet
filter chamber,
filter chamber,
soundsound
absorbing
absorbing
heat insulation,
heat insulation,
and aand
lowapressure-loss
low pressure-loss
HEPAHEPA
filter etc.
filter etc.
All models
All models
emit under
emit under
41dB 41dB
of noise.
of noise.
(38dB(38dB
during
during
low-power
low-power
operation)
operation)
*Operating
*Operating
noise may
noise
be greater
may bethan
greater
these
than
values
theseinvalues
highly in
reflective
highly reflective
locations.locations.

The outdoor
The outdoorunit also
unit operates
also operates
quietly.
quietly.
If setIftoset
night
to night
time quiet
time quiet
mode, mode,
the air
the
conditioner
air conditioner
becomes
becomes even even
quieter at night.
quieter at night.

Labor-saving
Labor-saving
Filter
Filter maintenance
maintenance unnecessaryfor
unnecessary forabout
aboutfive
fiveyears.
years.
Under-surface
Under-surface access
access system
system forfor easy
easy maintenance.
maintenance.
The HEPA
The HEPA
filter filter
has an has
exceptionally
an exceptionally
long long
life, not
life, not
requiring
requiring
maintenance
maintenance for about
for about
five years.
five years.
Daikin Daikin
has has
aimed aimed
to reduce
to reduce
maintenance
maintenance
workwork
from from
variousvarious
perspectives,
perspectives,
including
including
an under-surface
an under-surface
access access
systemsystem · HEPA filter
· HEPA filter · Fan · Fan · Drip pan· Drip
replacement
replacement inspection
inspection
inspection
pan inspection
· Pre-filter
· Pre-filter
replacement
replacement
that eliminates
that eliminates
the necessity
the necessity
for service
for service
panels panels
and an
and an
easilyeasily
detachable
detachablefan and
fan drip
and pan.
drip pan.
*The maintenance
*The maintenance
period differs
periodsignificantly
differs significantly
according according
to the cleanliness
to the cleanliness
of the room
of the
androom
operating
and operating
time of the
time
airof
conditioner.
the air conditioner.

Precise
Precise operation
operation androom
and roomtemperature
temperaturecontrol.
control.
Operation
Operation
is as is
easy
as easy
as forasanfor
ordinary
an ordinary
air conditioner.
air conditioner. WiredWired
liquidliquid
crystal
crystal i-touch
i-touch
controller
controller
Control
Control
by distant/dual
by distant/dual
remoteremote
control
control
operation
operation remote
remote
controller
controller
possible.
possible.
SystemSystem
is equipped
is equipped
with awith
self-diagnosis
a self-diagnosis
function that indicates
function the location
that indicates and details
the location in thein the
and details
eventevent
of a malfunction. Combine
of a malfunction. with awith
Combine controller that can
a controller that can
centrally control
centrally multiple
control air conditioners*
multiple to reduce
air conditioners* total total
to reduce
air conditioner management
air conditioner management workwork
in combination with with
in combination
otherother
air conditioners.
air conditioners.
*Individual
*Individual
control ofcontrol
up to 64
of up
groups
to 64possible
groups possible
by central
bycontrol.
central control.

4
Clean air conditioner P45/56/71

FBXYP-MA (P) HEPA filter sold separately

Easily realizing the clean environment of cleanliness class


10,000 required in ICUs, newborn nurseries and other
medical facilities and medical/food factories. Order product

Two types available according to the A HEPA filter of dust filtering efficiency Possible to incorporate an antibacterial
application. Possible to select the air 99.97% realizes an air cleanliness of HEPA filter employing antibacterial fiber
flow system and installation method in class 10,000*. (count method 0.3 µm) in the outlet filter (modified product).
*Cleanness class. A scale expressing the cleanliness The floor-level intake system prevents
accordance with the usage environment
of air established by NASA (National Aeronautics and
and purpose of the room. Space Administration). Class 10,000 represents a uncomfortable drafts with a low flow
state of under 10,000 minute particles of diameter speed of 0.5 m/s.
“Floor-level intake type” under 0.5 µm per cubic foot. For comparison, the Industry-leading meticulous quiet design.
cleanliness of a typical office is around class
A clean air flow spreads 1,000,000.
(Operation noise under 41dB for all
throughout the whole models)
The propagation of bacteria in the duct
Intake

room. Filter maintenance is unnecessary for


is suppressed by a new coating about five years*.
“Ceiling intake type” combining a silver-based inorganic Employs an under-surface access
antibacterial material effective against system for easy maintenance.
Provides concentrated air germs and an organic antibacterial *5 years (12500 hours)
conditioning focused material that Fan
8 hours/day x 26 days/month x 12 months/year x 5 years
directly under the outlet prevents mold. Intake filter Conditions: Room dust concentration: Class 10,000
and creates a clean zone. Intake
This inhibits the
(antibacterial fiber)
Outside air intake volume: 20% of rated air flow
Outside dust concentration: Class 1,000,000
* Integrated outlet and separate growth of mold Outlet panel HEPA filter
outlet unit models are available for each type. in the air (punched) (sold separately) or
Sheet steel
drain pan
Intake panel
(punched) Easy installation in existing structures
with the same installation work as for a
antibacterial HEPA filter (antibacterial

conditioner and
(modified product) treated)

keeps the duct hygienic. typical air conditioner.


Package type also available.

Outline drawing (units: mm)


Integrated outlet unit model
Ceiling intake type In the case of introducing outside air, please install a damper linked with the indoor unit fan.
(Mounting service space) Attention Please contact our customer service center about damper precautions and linkage methods.
1788 500 or more E
480 54
426 F
Hanging
bolt 414 44 G
3 1 2 75 232 H (Square hole)
Liquid pipe connection
(Mounting service space)
70

J
Gas pipe connection
345

210

Drain pipe connection


435

50

505 or more
(Square hole)
280

310
340
200

492

Power connection
392

ø226 P.C.D
312
203

5
6 730 917 4 66 188
Junction wiring connection
(Note 6) 27
(Main unit mounting dimensions) 12

ø210 hole (note 3) (fresh air intake)


10

10 K
4-M4 countersink (cyclotomic) Outlet panel
16-ø7 hole
14 13
View on arrow A
HEPA filter
(Note 2)

Inlet
7
1575 (Centered on outlet) L.L. filter
11 12 9 8 240 (Centered on inlet) Electrical components box
Shield plate
C (Ceiling aperture)

Panel frame
Back shield plate
Type A B C D E F G H J K
(A)

D
B

Main unit seal material


P45/56 820 860 1115 1150 1000 960 930 900 5×150=750 1050
This diagram is based on the
Outlet punching
(280) (300)
P71 1120 1120 1415 1450 1300 1260 1230 1200 5×200=1000 1350 FBXYP45/56MA.
Inlet punching
1840 (Ceiling aperture)
1880 1. Heat insulating material (polyethylene foam) is affixed to the inside of the outlet panel.
Notes) 2. This is the distance between the ceiling and the end face of the main unit plate. (Not the distance between the
ceiling and the seal material.)
3. In the case of drawing in air through the fresh air intake, install a damper linked with the indoor unit fan in the duct
and ensure that the air intake is cut off when the fan is stopped. It is possible for the taken-in air to flow backwards
through inlet filter and for the dust deposited in the filter to be returned to the room.
4. In the case of an installation in an operating theatre etc where an air conditioner malfunction may have serious
consequences, please build in redundancy with two or more outside units.
5. Please do not place things that must not become wet under the indoor unit. Condensation may fall in the case of
humidity of 80%, in the case the drainage outlet is blocked, or in the case the air filter is dirty.
6. This is the height excluding the screws for securing the outlet panel on the surface (height: 10 mm).

Floor-level intake type


In the case of introducing outside air, please install a damper linked with the indoor unit fan.
(Mounting service space) Attention Please contact our customer service center about damper precautions and linkage methods.
1788 500 or more D
480 54
426 E
Hanging 414
bolt 44 F
3 1 2 75 232 G (Square hole)
(Mounting service space)

Liquid piping connection


70

H
Gas piping connection
345

435

50

505 or more

210

Drain pipe connection


(Square hole)
280

310
340
200

492
392

Power connection
312

ø226 P.C.D
203

4
730 917
5
66 Junction wiring connection
(Main unit mounting dimensions) 12

6
10
65

9 ø210 hole (note 3) (fresh air intake)


J 188
4-M4 countersink (cyclotomic) Outlet panel
13 12
16-ø7 hole
HEPA filter
(Note 2)

View on arrow A
Inspection panel
1490 (Center of outlet panel)
Diffusion punching 7 Electrical components box
10 11 8
Shield plate
(45)

Panel frame
B (Ceiling aperture)

Back shield plate


Type A B C D E F G H J Main unit seal material
(A)

P45/56 918 1115 1150 1000 960 930 900 5×150=750 1050 This diagram is based on the
P71 1218 1415 1450 1300 1260 1230 1200 5×200=1000 1350 FBXYP45/56MA.
(45)

(45) (560) (45)


1840 (Ceiling aperture)
1880
Notes) 1. The back inlet companion flange is attached to the panel (BYBP82D56W or BYBP82D80W).
2. This is the distance between the ceiling and the end face of the main unit plate. (Not the distance between the ceiling
and the seal material.)
3. In the case of drawing in air through the fresh air intake, install a damper linked with the indoor unit fan in the duct
and ensure that the air intake is cut off when the fan is stopped. It is possible for the taken-in air to flow backwards
through inlet filter and for the dust deposited in the filter to be returned to the room.
4. In the case of an installation in an operating theatre etc where an air conditioner malfunction may have serious
consequences, please build in redundancy with two or more outside units.
5. Please do not place things that must not become wet under the indoor unit. Condensation may fall in the case of
humidity of 80%, in the case the drainage outlet is blocked, or in the case the air filter is dirty.
5
Outline drawing (units: mm)
Separate outlet unit model
Ceiling intake type
(Mounting service space) In the case of introducing outside air, please install a damper linked with the indoor unit fan.
500 or more
54
1300 Attention Please contact our customer service center about damper precautions and linkage methods.
1078
480 44 1260
Hanging 426 1230
bolt 414 1200 (Square hole)
3 1 2 232 12

(Mounting service space)


75

70
5×200=1000

50

210
505 or more
2×65=130

(Square hole)

(Square hole)
345

280

220
200

150
190
435

310
340

40
25

492
392
ø226 P.C.D

312
20-ø8 hole

203

(Main unit mounting dimensions) 12


6 188 ø210 hole (note 3) 7×150=1050

10
917 66 16-ø7 1350
(Fresh air intake) 1080 (Square hole)
hole 13 11 1110
4 5 4-M4 countersink
40-ø4.7 (cyclotomic) View on arrow A
hole

(Note 2)
7 10 9 8 240 (Centered on inlet)
Liquid piping connection Inlet
Gas piping connection L.L. filter
1415 (Ceiling aperture)

Drain pipe connection Panel frame


Power connection Back shield plate
16×65=1040

Junction wiring connection Outlet companion flange


(1120)

1450

Electrical components box Main unit seal material


Shield plate

(300)
Notes) 1. Please use a dedicated HEPA unit for the outlet filter unit.
Inlet punching
1130 (Ceiling aperture)
1170
2. This is the distance between the ceiling and the end face of the main unit plate. (Not the distance between the ceiling and the seal
material.)
3. In the case of drawing in air through the fresh air intake, install a damper linked with the indoor unit fan in the duct and ensure that
the air intake is cut off when the fan is stopped. It is possible for the taken-in air to flow backwards through inlet filter and for the
dust deposited in the filter to be returned to the room.
4. In the case of an installation in an operating theatre etc where an air conditioner malfunction may have serious consequences,
please build in redundancy with two or more outside units.
5. Please do not place things that must not become wet under the indoor unit. Condensation may fall in the case of humidity of 80%, in
the case the drainage outlet is blocked, or in the case the air filter is dirty.

Floor-level intake type


(Mounting service space) In the case of introducing outside air, please install a damper linked with the indoor unit fan.
500 or more 1300 Attention Please contact our customer service center about damper precautions and linkage methods.
1078 54
480 44 1260
Hanging 426 1230
bolt 414 1200 (Square hole) 11
3 1 2 232
(Mounting service space)

75
70

5×200=1000
50

505 or more

210
2×65=130

(Square hole)
(Square hole)

220
150
190
345

40
280
200
435

310
340

25
492
392

20-ø8 hole
312

ø226 P.C.D
203

188 7×150=1050
(Main unit mounting dimensions) 12

ø210 hole (note 4)


10

917 4 5 66 1350 1080 (Square hole)


40-ø4.7 (Fresh air intake)
16-ø7 hole 1110
hole 12 10 4-M4 countersink
9 8 View on arrow A
(cyclotomic)
(Note 2)
1415 (Ceiling aperture)

Liquid piping connection Inspection panel


16×65=1040

Gas piping connection Panel frame


1450

Drain pipe connection Back shield plate


Power connection Outlet companion flange
Junction wiring connection Main unit seal material
Electrical components box
1130 (Ceiling aperture) Shield plate
1170

Notes) 1. Please use a dedicated HEPA unit for the outlet filter unit.
2. This is the distance between the ceiling and the end face of the main unit plate. (Not the distance between the ceiling and the seal
material.)
3. The back inlet companion flange is attached to the panel (BYBP82D56WP).
4. In the case of drawing in air through the fresh air intake, install a damper linked with the indoor unit fan in the duct and ensure that
the air intake is cut off when the fan is stopped. It is possible for the taken-in air to flow backwards through inlet filter and for the
dust deposited in the filter to be returned to the room.
5. In the case of an installation in an operating theatre etc where an air conditioner malfunction may have serious consequences,
please build in redundancy with two or more outside units.
6. Please do not place things that must not become wet under the indoor unit. Condensation may fall in the case of humidity of 80%, in
the case the drainage outlet is blocked, or in the case the air filter is dirty.

Outlet unit Outlet unit


(Ceiling intake type) (Floor-level intake type)
Hanging 700 1300 Hanging 700 1300
bolt bolt
(Mounting service space)

(Mounting service space)


505 or more

505 or more
2×65=130

2×65=130
(Square hole)

(Square hole)
190

220

190

220
150
40

40
150
345

345
492

492

20-ø8 hole 20-ø8 hole


12 (Main unit mounting dimensions)

7×150=1050
7×150=1050
(Main unit mounting dimensions) 12
10

65
27 (Note 3)
10

1080 (Square hole)


1 1 1080 (Square hole)
5 1110 5
(Note 2)

1110
(Note 1)

(280)
(45) (594) (45)
480 4 4
(45)

2 2

40-ø4.7 hole 40-ø4.7 hole


3 3
(Ceiling aperture)

(Ceiling aperture)
16×65=1040

16×65=1040
(1120)

(1218)
1350

1350
1450
1415

1450
1415

Outlet panel Outlet panel


HEPA filter HEPA filter
Ceiling shield Ceiling shield
decorative frame decorative frame
Companion flange Companion flange
750 (Ceiling aperture) 550 Main unit seal material 750 (Ceiling aperture) 550 Main unit seal material
(45)

790 790
View on arrow A View on arrow A

Notes) 1. Heat insulating material (polyethylene foam) is affixed to the inside of the Notes) 1. This is the distance between the ceiling and the end face of the main unit
outlet panel. plate. (Not the distance between the ceiling and the seal material.)
2. This is the distance between the ceiling and the end face of the main unit
plate. (Not the distance between the ceiling and the seal material.)
3. This is the height excluding the screws for securing the outlet panel on the
surface (height: 10 mm).

6
Standard specifications (50/60Hz)
Type Integrated outlet unit model Separate outlet unit model
Indoor unit FBXYP45MA FBXYP56MA FBXYP71MA FBXYP71MAP
Model name
Outlet unit Integrated with the indoor unit BAFJ82B80
Power Single phase 200V (power supply also necessary for the indoor unit) 50/60 Hz
Cooling capacity *1 kW 4.5 5.6 7.1
Heating capacity * 2 kW 5.0 6.3 8.0
Rated power When cooling * W 220/280 330/350 423/479
1

consumption When heating * 2 W 220/280 330/350 423/479


Intake filter efficiency * 3
70% by gravimetric method
Outlet HEPA filter efficiency * 4
99.97% by DOP method * 7

Unit weight kg 140 *5 170 *5 100 *8


Motor output x number of units W 135×1 165×1
Fan
Air flow (strong – weak) m3/min 19−16/18−15 24−19/22.5−17.5
Operation noise (strong – weak) *6 dB 41−38
Outlet unit weight kg — 70 *5
Pipe Liquid pipe/gas pipe (øC1220T) mm 6.4/12.7 flare 9.5/15.9 flare
connections Drain pipe PT1B male screw
*1 JIS B 8616 condition (indoor: 27°C DB/19°C WB, outside air: 35°C DB), pipe connection 7.5 m (equivalent length), height 0 m.
*2 JIS B 8616 condition (indoor: 20°C DB, outside air: 7°C DB/6°C WB), pipe connection 7.5 m (equivalent length), height 0 m.
*3 An intake air filter is only attached to the ceiling intake type.
*4 HEPA filter sold separately.
*5 Weight including HEPA filter and panel.
*6 Anechoic chamber conversion value under JIS B 8616 test conditions. Value usually increases slightly in practice due to surrounding conditions.
*7 The clean air conditioner does not support DOP testing (leak test) based on GMP standards (Standards for Manufacturing Control and Quality Control for Medical Devices ) due to slight leakage at time of
product installation.
*8 Weight including panel.

*In the case of an installation in an operating theatre etc where an air conditioner malfunction may have serious consequences, please build in redundancy with two or more outside units.

Clean air conditioner: FBXYP-MA (P)


Type Integrated outlet unit model Separate outlet unit model
Model name FBXYP45MA · 56MA FBXYP71MA FBXYP71MAP
Outlet unit model name — BAFJ82B80
Operation Wired liquid crystal BRC1E62
remote
Operation controller Wireless liquid crystal Separate light receiver type BRC4L1
control
Intelligent touch manager DCM601A1
Standard HEPA filter (Note 1) BAFHJ82A56 BAFHJ82A80
Filter
Antibacterial HEPA filter (Note 1) (Note 2) NAFJ82A56B NAFJ82A80B
Ceiling intake type BYBP82D56C BYBP82D80C BYBP82D80CP
Panel
Floor-level intake type BYBP82D56W BYBP82D80W BYBP82D80WP
Outside air intake duct flange KDFJ82A80 3,800 yen
(Note 1) The standard HEPA filter and the antibacterial HEPA filter cannot be used together.
(Note 2) The antibacterial HEPA filter is a modified product.

• Items marked in the option list are handled by Daikin Industries, Ltd. All other s are handled by O.K . KIZ AI CO., LTD.

Installation and handling precautions

Clean air conditioners


• In the case a high cleanliness and air conditioning at the floor level is
Outline of simple clean air conditioner model selection at a medical institution
important, please deploy the <Floor-level inlet type>.
1 Calculate the outside air intake volume.
• In the case of drawing in air through the fresh air intake, the taken-in air may
Minimum outdoor intake volume QF (m3/h) = room volume (m3) x minimum outside air ventilation frequency (times/h) flow backwards through inlet filter and the dust deposited in the filter may be
2 Calculate the air-conditioning load. returned to the room. Accordingly, please install a damper linked with the
Please calculate taking into account the outside air intake volume. indoor unit fan in the duct and ensure that the air intake is cut off when the
3 Calculate the necessary air volume. fan is stopped.
Minimum necessary air volume QS (m3/h) = room volume (m3) x minimum circulated air volume ventilation frequency (times/h) • The entry of gas disinfectant into the air conditioner may cause a
malfunction, so please turn off the air conditioner and cover the inlet and
4 Select the model capacity.
Model required by air-conditioning load calculation: X,
outlet with vinyl sheeting etc when sterilizing operating theatres etc in which
model required by minimum necessary air volume calculation: Y the air conditioner is installed in medical institutions.
· X>Y: Select model X. · X<Y: Select model Y, or model X + fan filter unit* • The clean air conditioner does not support DOP testing (leak test) based on
· X=Y: Select either X or Y. GMP standards (Standards for Manufacturing Control and Quality Control
Please procure a fan filer unit (fan + HEPA filter).
Also, please make sure to ensure the minimum necessary air volume QS with the air conditioner and
for Medical Devices).
the fan filer unit.
Outside air intake volume (Table 1)
Zone Minimum outside air volume
name Facility name ventilation frequency (times/h)
Operating theatre Surgery prep room Pantry
Wound irradiation chamber Emergency operating theatre
Neonatal intensive care unit (NICU) Clean corridor 5
Clean area
Aseptic dispensing pharmacy Hand washing station
A
Pre-sterilized room of the central materials store
Maternity room 4
Premature nursery Some areas of the surgery section
Recovery room Operation locker room ICU
Clean area 3
Special laboratory Outpatient surgery
B Some areas of the central materials store Dialysis room Head Office:
Special medical ward 2 Wisma KEIAI, 18th Floor
1989: According to the Healthcare Engineering Association of Japan’s “Design and Management
Jl. Jendral Sudirman Kav 3, Jakarta Pusat 10220
Guidelines for Hospital Air Conditioner Facilities.” Telp : +6221-572 4377
Fax : +6221-572 4366/55
Minimum circulated air volume ventilation frequency: 30 times/h (Table 2) <For a general operating theatre>
Website : http://www.daikin.co.id
Airborne particles Viable biological Pressure By air
Clean Service and Spare Parts, Telp.: 021-736 92899 ● Training Center, Telp.: 021-295 61950 ● Bandung,
room class Diameter Cumulative particle particlecount difference turbulence
(µm or more) count (particles/ft3) (particles/ft3) (mmAq) method Telp.: 022-601 4781 ● Semarang, Telp.: 024-841 2695 ● Surabaya, Telp.: 031-503 1138 ● Denpasar,
Telp.: 0361-900 5514 ● Makassar, Telp.: 0411-446 263 ● Palembang, Telp.: 0711-319 776
10,000 0.5 10,000 (350/ ) 0.5 (0.0176/ ) 1.27 Over 20 times
Daikin Contact Center : 0800 1 081 081 (Toll Free)