INSTALLATION
MANUAL
BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM
Model: HLD‐BNWAS100
Code HLD8000AZ
Version V2.1
Date 2011‐11‐18
BEIJING HIGHLANDER DIGITAL
TECHNOLOGY CO., LTD.
VERSION
Date Version Issued by Description
Applicable to ODU version
2011‐10‐23 V2.1 BNWAS Team
V2.2 and INU version V2.2
IMPORTANT SAFETY MESSAGE
SAFETY OPERATION OF VESSEL IS THE
RESPONSIBILITY OF THE ONBOARD
NAVIGATION OFFICERS OR USERS.
“WARNING”, “CAUTION” and “NOTICE” notices appear throughout this manual. It is
the responsibility of the user to read, understand and follow these notices. If you have
any questions regarding these safety instructions, please contact HIGHLANDER!
This notice indicates a potentially
hazardous situation which, if not
avoided, will result in death or serious
injury.
This notice indicates a potentially
hazardous situation which, if not
avoided, could result in minor or
moderate injury, or property damage.
This notice indicates an unsafe
operation which, if not avoided, could
result in property damage or equipment
malfunction.
Observe handling regulations!
Removal or insertion of a subgroup or printed
wiring board with live voltage can lead to
severe damage.
CONTENTS
SAFETY INSTRUCTIONS .................................................................................................... 3
1 SYSTEM INTRODUCTION................................................................................................ 1
2 INSTALLATION RECOMMENDATIONS............................................................................. 1
2.1 General Recommendations ................................................................................ 1
2.2 Cables.................................................................................................................. 2
2.3 Compass Safe Distance ....................................................................................... 3
3 INTERFACE UNIT............................................................................................................. 4
3.1 Mounting Procedures ......................................................................................... 4
3.2 Interfaces ............................................................................................................ 7
4 OPERATION DISPLAY UNIT ........................................................................................... 10
4.1 Mounting Procedures ....................................................................................... 10
4.2 Interfaces .......................................................................................................... 13
5 ALARM UNIT ................................................................................................................ 15
5.1 Mounting Procedures ....................................................................................... 15
5.2 Interfaces .......................................................................................................... 25
6 RESET UNIT .................................................................................................................. 26
6.1 Mounting Procedures ....................................................................................... 26
6.2 Interfaces .......................................................................................................... 29
7 POWER CONVERSION UNIT ......................................................................................... 30
7.1 Mounting Procedures ....................................................................................... 30
7.2 Interfaces .......................................................................................................... 33
8 MOTION SENSOR ......................................................................................................... 34
8.1 Mounting Procedures ....................................................................................... 34
8.2 Interfaces .......................................................................................................... 43
9 TERMS AND DEFINITION.............................................................................................. 44
APPENDIX A SPECIFICATIONS OF TOOLS FOR INSTALLATION ......................................... 45
APPENDIX B SYSTEM INTERFACE DRAWING................................................................ 46
i
Beijng Highlander Digital Technology Co., Ltd.
1 SYSTEM INTRODUCTION
For this part, please refer to the chapter 1 of “OPERATION MANUAL”.
2 INSTALLATION RECOMMENDATIONS
2.1 General Recommendations
Dimensions, weights, spaces required by service and maintenance and special
installation instructions are stated in the outline drawings and installation drawings of
corresponding unit.
In general, the following instructions should be applied:
• The useful life of the components of all Electronics Units generally decreases with
increasing ambient temperature, therefore, it is advisable to install such units in
air‐conditioned rooms.
• For most Electronics Units, cooling takes place via the surface of the casing. The
cooling must not be installed in a confined cabinet. Furthermore, the distance from
the ceiling to the floor or from a unit situated underneath must be at least 500
mm.
• In the area of the wheel house, the distance of each Electronics Unit from the
magnetic standard compass or the magnetic steering compass must not be less
than the permitted magnetic protection distance (see section 2.3). This distance is
measured from the centre of the magnetic system of the compass to the nearest
point on the corresponding unit concerned.
• Units which are to be used on the bridge wing must be installed inside the "wing
control console" ‐‐ protected against the weather.
• When selecting the site of a unit, the maximum cable lengths have to be
considered according to the notes in section 2 Cables.
• The accessibility for maintenance and service must be considered.
• Disturbing reflections on the screen of a display caused by pilot lamps and
illuminated signs must be prevented by suitable measures (screening or
relocating).
Doc. Code: HLD8000AZ 1 Version: V 2.1
Bridge Navigational Watch Alarm System INSTALLATION MANUAL
• The grounding screws of the units must be connected to the body of the ship
(ground); the wire used should have a cross sectional area of at least 3 mm.
Aboard fiberglass (GRP) vessels, a "grounding network" with a high conductance
must be provided in order to achieve satisfactory EMC (electromagnetic
compatibility).
• The equipment should never be switched on by the electricians who did the
installation work ‐‐ not even just for a moment! This is a job for the authorized
Highlander Electronics service engineer.
• After handing over of the equipment in good operating condition to the customer,
the Installation Report (Annex of the Warranty Certificate) should be filled in
completely and then forwarded to Highlander as proof of such fulfilment. It is
important that these requirements be fulfilled in order to avoid the risk of losing
the warranty.
2.2 Cables
Cable types, cable data, special instructions for cable laying and connection details are
defined in the Connection Diagram. The cable type and the connection need to be
according to the Connection Diagram.
In general, the following points must be taken into account:
• The cables must be marked by the electrician at both ends with the cable numbers
corresponding to the Connection Diagram. Where necessary, particular cable
glands ‐ marked with letters and/or numbers ‐ are assigned to the cables.
• It must be ensured that all cables ‐ including their screens ‐ are passed into the
units in continuous lengths and are not terminated before reaching the
destination unit.
• With the use of cable glands without grounding inserts, the screen braiding need
to place outside the unit and plaited to form a "pigtail", terminated by a cable
terminal, and connected to the prescribed grounding terminal. It must be ensured
that the grounding lead is kept as short as possible.
• In the case of a unit whose cable inlet consists of a hole with brackets attached on
the outside, the cable must be dressed as shown in figure 1.
Doc. Code: HLD8000AZ 2 Version: V 2.1
Beijng Highlander Digital Technology Co., Ltd.
100
Crimp Connector
40.00
Shielding layer
Figure 1: Cable inlet consisting of a hole with brackets
• All cable connections must be carefully checked after completion of the cable work
and all cable screens must be grounded via the shortest possible connections ‐ if
not stated otherwise in the Connection Diagram.
• All cables must be secured by means of suitable clamps (wire tie) before entering
the units.
• It must be ensured that cables do not block any moving parts within a unit.
• Power leads must be protected by "slow‐blow" fuses according to their cross
section.
2.3 Compass Safe Distance
Doc. Code: HLD8000AZ 3 Version: V 2.1
Bridge Navigational Watch Alarm System INSTALLATION MANUAL
3 INTERFACE UNIT
3.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
The Interface Unit is installed wall‐mounted inside the bridge control console.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
cute angle, pinch, twist, or impart
Observe the distance to a magnetic excessive force.
compass when the mounting place is
defined. Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are Observe precautions for handling
disconnected from any power supply. electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install the Interface Unit into the position reserved for its installation in the bridge
control console. Refer to the Mounting Drawing for the details of the installation cut
out;
2) Secure the Interface Unit with M8 screws at the positions as illustrated in the
Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set;
4) Ground the Interface Unit. Utilize a special ground wire on the ship to bind to the
ground bolt of the Interface Unit, and secure it with screws.
Doc. Code: HLD8000AZ 4 Version: V 2.1
M6接地螺栓
GROUND TERMINAL,STUD M6.0
162.5
345 148.5
285 138.5 320
? 8.5(4*)
安装孔
MOUNTING HOLES
225
420
350
最小100mm内无障碍物 162.5
345 148.5
285 min.100 clearance 138.5
? 8.5(4*)
安装孔
MOUNTING HOLES
420
350
M6接地螺栓
GROUND TERMINAL,STUD M6.0
电缆进线空间
CABLE CONNECTION SPACE min.300 clearance
进线处(最小300mm内无障碍物)
说明(Note):
min.200clearance
min.100 clearance
最小200mm内无障碍物 1.图中给出了安装所需余留空间(用Min.表示);
最小100mm内无障碍物
Installation clearance requirement has
been indicated using Min .;
2.依据安装手册的安装步骤进行安装 。
Mounts according to the process of
installation manual.
最小250mm内无障碍物
min.250 clearance
Beijng Highlander Digital Technology Co., Ltd.
3.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Interface Unit is shown in figure 2, 3 and table 1.
03 02 01 03 02 01
V-
V+
V-
V+
E
E
D2 D1
C1 C2 C3 C4 C5 C6
ISO.G
ISO.G
ISO.G
ISO.G
ISO.G
ISO.G
C
24V
DI1
24V
DI2
24V
DI3
24V
DI4
24V
DI5
24V
DI6
01 02 03 01 02 03 01 02 03 01 02 03 01 02 03 01 02 03
B1 B2 B3 B4 B5 B6
DO1
DO2
DO3
DO4
DO5
DO6
B
GND
GND
GND
GND
GND
GND
01 02 01 02 01 02 01 02 01 02 01 02
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
A
RX+
RX-
TX+
TX-
GND
24V
A
B
B
01 02 03 04 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02
Figure 2: Interface of Interface Unit
Doc. Code: HLD8000AZ 7 Version: V 2.1
Bridge Navigational Watch Alarm System INSTALLATION MANUAL
E 03
- 02
+ 01
E 03
- 02
+ 01
BATTERY
E MAIN D
POWER POWER
24V 24V
C1 C2 C3 C4 C5 C6
HLD-REU 100 RESET UNITS/HLD-MOS MOTION ALARM
FROM AP
SENSORS OR EXTERNAL INPUTS TRANSFER
GND
GND
GND
GND
24V
24V
24V
24V
INPUT INPUT
SIG
SIG
SIG
SIG
C
X
01 02 03 01 02 03 01 02 03 01 02 03 01 02 03 01 02 03
B1 B2 B3 B4 B5 B6
HLD-ALR 100 ALARM UNIT VISUAL VISUAL
AUDIBLE ALARM OUTPUTS ALARM ALARM
1ST 2ND 3RD OUTPUT OUTPUT B
+
_
_
01 02 01 02 01 02 01 02 01 02 01 02
A1 A2 A3 A4 A5 A6 A7 A8 A9 A10
HLD-ODU 100 IEC 61162-1 SERIAL SENTENCES
COMMUNICATION
TO FROM FROM RADAR/ECDIS RESERVED
A
GND
--EVE SENTENCES
RX+
TX+
VDR AP
24V
RX-
TX-
B
A
B
A
A
B
A
B
01 02 03 04 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02
Figure 3: Definition of Interfaces of Interface Unit
Table 1: Plug Define of Interface Unit
Plug/Terminal Remarks
MAIN POWER‐01 Main Power supply 24V input
MAIN POWER ‐02 Main Power supply GND input
MAIN POWER ‐03 Earth
BATTERY POWER‐01 Emergency Power supply 24V input
BATTERY POWER ‐02 Emergency Power supply GND input
BATTERY POWER ‐03 Earth
A1‐01 Reticle TX+(twisted with TX‐)
A1‐02 Reticle TX‐(twisted with TX+)
A1‐03 Reticle RX+(twisted with RX‐)
A1‐04 Reticle RX‐(twisted with RX+)
A2‐01 Power supply GND input
A2‐02 Power supply 24V input
A3‐01 COM1(485‐A)To VDR
A3‐02 COM1(485‐B)To VDR
A4‐01 COM2(485‐A)From AP
A4‐02 COM2(485‐B)From AP
A5‐01 COM3(485‐A)
A5‐02 COM3(485‐B)
A6‐01 COM4(485‐A)
A6‐02 COM4(485‐B)
A7‐01 COM5(485‐A)Reserved
A7‐02 COM5(485‐B)Reserved
A8‐01 COM6(485‐A)Reserved
Doc. Code: HLD8000AZ 8 Version: V 2.1
Beijng Highlander Digital Technology Co., Ltd.
Plug/Terminal Remarks
A8‐02 COM6(485‐B)Reserved
A9‐01 COM7(485‐A)Reserved
A9‐02 COM7(485‐B)Reserved
A10‐01 COM8(485‐A)Reserved
A10‐02 COM8(485‐B)Reserved
B1‐01 1ST +
B1‐02 1ST ‐
B2‐01 2ND +
B2‐02 2ND ‐
B3‐01 3RD +
B3‐02 3RD ‐
B4‐01 VIS +
B4‐02 VIS ‐
B5‐01 VIS +
B5‐02 VIS ‐
B6‐01 MALF OUT
B6‐02 MALF OUT
C1‐01 24V
C1‐02 GND
C1‐03 SIG
C2‐01 24V
C2‐02 GND
C2‐03 SIG
C3‐01 24V
C3‐02 GND
C3‐03 SIG
C4‐01 24V
C4‐02 GND
C4‐03 SIG
C5‐01 NC
C5‐02 From AP
C5‐03 From AP
C6‐01 NC
C6‐02 Alarm Transfer
C6‐03 Alarm Transfer
Doc. Code: HLD8000AZ 9 Version: V 2.1
Bridge Navigational Watch Alarm System INSTALLATION MANUAL
4 OPERATION DISPLAY UNIT
4.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
The Operation Display Unit is installed desktop‐mounted or wall‐mounted on the wall
inside the bridge control console.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
cute angle, pinch, twist, or impart
Observe the distance to a magnetic excessive force.
compass when the mounting place is
defined. Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are Observe precautions for handling
disconnected from any power supply. electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install the Operation Display Unit into the position reserved for its installation in
the bridge control console. Refer to the Mounting Drawing for the details of the
installation cut out;
2) Secure the Operation Display Unit with M4 screws at the positions as illustrated in
the Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set.
4) Ground the Operation Display Unit. Utilize a special ground wire on the ship to
bind to the ground bolt of the Operation Display Unit, and secure it with screws.
? 20
192
178
59
?5
安装孔
MOUNTING HOLES
178
192
60
100
60
ACK. EMERG.
ALARM CALL
100
SET EXIT
MENU CANCEL
75
旧底图总号
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 设 计
审 核
工 艺
日期 签名 第 张 共 张
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
版本号
? 20
出线孔
CABLE ENTRY 出线孔
192 CABLE ENTRY
178
59
安装孔
MOUNTING HOLES
178
192
60
100
60
ACK. EMERG.
ALARM CALL
100
SET EXIT
MENU CANCEL
75
说明(Note):
1.图中给出了安装所需余留空间(用Min.表示);
旧底图总号 Installation clearance requirement has been indicated using Min.;
2.依据安装手册的安装步骤进行安装。
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 Mounts according to the process of installation manual. 设 计
审 核
工 艺
日期 签名 第 张 共 张
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
Beijng Highlander Digital Technology Co., Ltd.
4.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Operation Display Unit is shown in figure 4 and table 2.
A
2
A
1
+ - + - D V
X X X X N 4
T T R R G 2
0
1
0
2
0
3
0
4
0
1
0
2
Figure 4: Interface of Operation Display Unit
Table 2: Plug Define of Operation Display Unit
Plug/Terminal Remarks
A1‐01 Reticle TX+(twisted with TX‐)
A1‐02 Reticle TX‐(twisted with TX+)
A1‐03 Reticle RX+(twisted with RX‐)
A1‐04 Reticle RX‐(twisted with RX+)
A2‐01 Power supply GND input
A2‐02 Power supply 24V input
5 ALARM UNIT
5.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
The Alarm Units includes first‐level, second‐level and third‐level Alarm Unit.
• One of the first‐level Alarm Unit is installed desktop‐mounted or wall‐mounted on
the wall inside the bridge control console. The other two first‐level Alarm Units are
installed desktop‐mounted or wall‐mounted on the wall inside the bridge.
• The second‐level Alarm Unit is installed wall‐mounted in the back‐up officer’s
and/or Master’s location.
• The third‐level Alarm Unit is installed wall‐mounted at the locations of further
crew members capable of taking corrective actions.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
cute angle, pinch, twist, or impart
Observe the distance to a magnetic
excessive force.
compass when the mounting place is
defined.
Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are
disconnected from any power supply. Observe precautions for handling
electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install all levels Alarm Unit into the position reserved for its installation. Refer to the
Mounting Drawing for the details of the installation cut out;
2) Secure the Alarm Unit with M3 screws at the positions as illustrated in the
Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set.
126
84,50
96
114±0,1
75,00
安装孔
?5(4*)
MOUNTING HOLES
BNWAS Alarm Unit
HLD-ALR100
80
96
56±0,1
出线孔
?22,00
CABLE ENTRY
旧底图总号
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 设 计
审 核
工 艺
日期 签名 第 张 共 张
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
版本号
壁挂安装
wall mounting
126
84,50
96
114±0,1
75,00
安装孔
? 5(4*)
MOUNTING HOLES
BNWAS Alarm Unit
HLD-ALR100
80
96
56±0,1
出线孔
? 22,00
CABLE ENTRY
说明(Note):
1.图中给出了安装所需余留空间(用Min.表示);
旧底图总号
Installation clearance requirement has
been indicated using Min .; 标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 2.依据安装手册的安装步骤进行安装 。 设 计
Mounts according to the process of 审 核
installation manual. 工 艺
日期 签名 第 张 共 张
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
Beijng Highlander Digital Technology Co., Ltd.
5.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Alarm Unit is shown in figure 5 and table 3.
Figure 5: Interface of Alarm Unit
Table 3: Plug Define of Alarm Unit
Plug/Terminal Remarks
A‐01 Power supply + input
A‐02 Power supply ‐ input
6 RESET UNIT
6.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
One of the Reset Unit is installed desktop‐mounted or wall‐mounted on the wall inside
the bridge control console.
The other two Reset Units are installed desktop‐mounted or wall‐mounted on the wall
inside the bridge.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
cute angle, pinch, twist, or impart
Observe the distance to a magnetic
excessive force.
compass when the mounting place is
defined.
Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are
Observe precautions for handling
disconnected from any power supply.
electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install the Reset Unit into the position reserved for its installation. Refer to the
Mounting Drawing for the details of the installation cut out;
2) Secure the Reset Unit with M3 screws at the positions as illustrated in the
Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set.
126
106,50
96
114±0,1
75,00
安装孔
? 5(4*)
MOUNTING HOLES
BNWAS Reset Unit
HLD-REU100
80
96
56±0,1
出线孔
? 22,00
CABLE ENTRY
旧底图总号
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 设 计
审 核
工 艺
日期 签名 第 张 共 张
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
版本号
126
106,50
96
114±0,1
75,00
安装孔
? 5(4*)
MOUNTING HOLES
BNWAS Reset Unit
HLD-REU100
壁挂安装(室内)
80
96
wall mounting(Indoor)
56±0,1
出线孔
? 22,00
CABLE ENTRY
106.5
114±0.1
96 75 M4(4*)
安装孔
MOUNTING HOLES
BNWAS Reset Unit
HLD-REU100
壁挂安装(室外)
wall mounting(Outdoor)
96
117
56±0.1
进线处(最小150mm内无障碍物)
min.150 clearance
说明(Note):
1.图中给出了安装所需余留空间(用Min.表示);
旧底图总号 Installation clearance requirement has been
indicated using Min .;
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号
2.壁挂安装室内和室外安装孔相同。 设 计
Wall mounting have the same mounting holes; 审 核
3.依据安装手册的安装步骤进行安装 。 工 艺
日期 签名 Mounts according to the process of 第 张 共 张
installation manual. 标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3
Beijng Highlander Digital Technology Co., Ltd.
6.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Reset Unit is shown in figure 6 and table 4.
Figure 6: Interface of Reset Unit
Table 4: Plug Define of Reset Unit
Plug/Terminal Remarks
A‐X1 VIS signal + input
A‐X2 VIS signal ‐ input
A‐23 signal GND
A‐24 Reset signal SIG
7 POWER CONVERSION UNIT
7.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
The Power Conversion Unit is installed wall‐mounted inside the bridge control console.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
Observe the distance to a magnetic cute angle, pinch, twist, or impart
compass when the mounting place is excessive force.
defined.
Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are
disconnected from any power supply. Observe precautions for handling
electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install the Power Conversion Unit into the position reserved for its installation in
the bridge control console. Refer to the Mounting Drawing for the details of the
installation cut out;
2) Secure the Power Conversion Unit with M8 screws at the positions as illustrated in
the Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set.
4) Ground the Power Conversion Unit. Utilize a special ground wire on the ship to bind
to the ground bolt of the Power Conversion Unit, and secure it with screws.
105
273
292
105
min.50 clearance
最小50mm内无障碍物
min.50 clearance
最小50mm内无障碍物
min.50 clearance
最小50mm内无障碍物
136
145
155
179
? 5(6*)
安装孔
Mounting holes
165
105
说明(Note):
1.图中给出了安装所需余留空间(用Min.表示);
Installation clearance requirement has been indicated using Min.;
2.依据安装手册的安装步骤进行安装 。
273
292
Mounts according to the process of installation manual.
105
Beijng Highlander Digital Technology Co., Ltd.
7.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Power Conversion Unit is shown in figure 7 and table 5.
02 V-
B
01 V+
01 02 03
A
G
+
Figure 7: Interface of Power Conversion Unit
Table 5: Plug Define of Power Conversion Unit
Plug/Terminal Remarks
A1‐01 220V AC (L) input
A1‐02 Shielded cable
A1‐03 220V AC (N) output
A2‐01 24V DC output
A2‐02 GND DC output
8 MOTION SENSOR
8.1 Mounting Procedures
(1) Tools for installation:
Inner hexagonal screw driver tool set, cast terminal crimping pliers.
The specifications of the tools are listed in Appendix A.
(2) Installation position
As optional component, the motion sensor is installed wall‐mounted inside the bridge
as needed.
(3) Mounting procedures
Installation must be performed by While connecting cables to the
trained and qualified personnel. equipment, do not bend cables to a
cute angle, pinch, twist, or impart
Observe the distance to a magnetic excessive force.
compass when the mounting place is
defined. Cracks or damage to the cable coating
When establishing cable connections, can cause a fire or electrical shock.
please ensure the cables are Observe precautions for handling
disconnected from any power supply. electrostatic sensitive devices (ESD).
It is essential to ensure that all cables
are disconnected from the power
supply. If necessary, measure the
voltage beforehand and/or disconnect
the relevant distributor.
1) Install the Motion Sensor into the position reserved for its installation in the bridge
control console. Refer to the Mounting Drawing for the details of the installation
cut out;
2) Secure the Motion Sensor with M4 screws at the positions as illustrated in the
Mounting Drawing;
3) Use spring washer and plain washer when installing the screws, and fasten them
with inner hexagonal screw driver tool set.
25,00
? 135,00
? 3(4*)
安装孔
MOUNTING HOLES
出线孔
CABLE ENTRY
旧底图总号
标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 设 计
审 核
工 艺
日期 签名 第 张 共 张
标准化
批 准
格式( ) 制图: 描图: 幅面:A3
版本号
25,00
? 135,00
? 3(4*)
安装孔
MOUNTING HOLES
出线孔
CABLE ENTRY
安装板
80
说明(Note):
1.图中给出了安装所需余留空间(用 Min.表示);
Installation clearance requirement has been indicated using mm Min. ;
2.依据安装手册的安装步骤进行安装。
Mounts according to the process of installation manual.
50,06
? 3.5(4*)
安装孔
MOUNTING HOLES
旧底图总号
51
12,50 标记 数量 更改单号 签名 日期 版本 标记 质量 比例
底图总号 设 计
? 15,00 审 核
工 艺
日期 签名 第 张 共 张
标准化
批 准
格式( ) 制图: 描图: 幅面:A3
Beijng Highlander Digital Technology Co., Ltd.
8.2 Interfaces
Descriptions are for explanation only.
Please refer to the specific project
documentation also.
The interface of Motion Sensor is shown in figure 8 and table 6.
Figure 8: Interface of Motion Sensor
Table 6: Plug Define of Motion Sensor
Plug/Terminal Remarks
A‐01 None
A‐02 None
A‐03 Reset signal output
A‐04 signal GND
A‐05 Power supply GND input
A‐06 Power supply 24V input
9 TERMS AND DEFINITION
TERMS DEFINITION
AUTO Automatic
BNWAS Bridge Navigational Watch Alarm System
COM Component Object Model
EMC Electromagnetic Compatibility
ESD Electrostatic Sensitive Device
GRP Glass Reinforced Plastic
IEC International Electrotechnical Commission
LED Light‐Emitting Diode
OOW Officer of the watch
Td Dormant period
VDR Voyage Data Recorder
APPENDIX A SPECIFICATIONS OF TOOLS FOR
INSTALLATION
Inner hexagonal tool set
2 Cast Terminal Crimping Pliers 0.08 to 6 mm²
HLD9000JX
V1.5 接口单元
Interface Unit 运动传感器 运动传感器
HLD-INU 100 Motion Sensor Motion Sensor
HLD-MOS 100 HLD-MOS 100
C1 C2 C3 C4 C5 C6 (Optional)选配 (Optional)选配
复位单元 复位单元
Reset Unit Reset Unit HLD-REU 100 RESET UNITS/HLD-MOS MOTION ALARM - + - +
FROM AP TAMPER ALARM TAMPER ALARM
SENSORS OR EXTERNAL INPUTS TRANSFER 24VDC 24VDC
HLD-REU 100 HLD-REU 100
INPUT INPUT
X
X
24V
24V
24V
24V
GND
SIG
GND
SIG
GND
SIG
GND
SIG
C
T2
T2
24V
24V
T1
SIG-A
SIG-B
T1
SIG-A
SIG-B
GND
GND
SIG
-
SIG
+
GND
+
GND
01 02 03 01 02 03 01 02 03 01 02 03 01 02 03 01 02 03
X1 X2 23 24 X1 X2 23 24 01 02 03 04 05 06 01 02 03 04 05 06
1 2 3 1 2 3 1 2 3 1 2 3 2 3 2 3
2 1
1 1' 2 3 1 1' 2 3 Note 1 3 3 2 1
CHVVP/SA 1X2X0.5 Alarm Transfer(报警转移)
CHVVP/SA 1X2X0.5 FROM AP 自动舵
CHVVP/SA 3X0.5 Note 2
CHVVP/SA 4X0.5 Note 2
1 1' 1 1'
B1 B2 B3 B4 B5 B6
报警单元 报警单元
HLD-ALR 100 ALARM UNIT VISUAL VISUAL
AUDIBLE ALARM OUTPUTS ALARM ALARM
Alarm Unit Alarm Unit
报警单元 报警单元 HLD-ALR 100 HLD-ALR 100
1ST 2ND 3RD OUTPUT OUTPUT
+
_
+
_
+
_
+
_
+
_
Alarm Unit Alarm Unit B
HLD-ALR 100 HLD-ALR 100
_
+
01 02 01 02 01 02 01 02 01 02 01 02
_
+
-
_
+
+
01 02 01 02 CHVVP/SA 1X2X0.5 Malfunction(失效报警输出)
1 1' 1 1'
+
+
TX+
TX-
B
B
B
B
B
B
24V
B
B
RX+
RX-
GND
A
A
A
A
A
A
A
A
01 02 01 02
TX+ 01 01 02 03 04 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02 01 02 1 1' 1 1'
第二级听觉报警
1 Green
TX- 02 1' Green White CAT5 1 1' 2 2' 1 1' 1 1' 1 1' 1 1' 1 1'
操作显示单元
APPENDIX B SYSTEM INTERFACE DRAWING
-
-
+
+
E
TERMINAL
H3801-6 01 02 03 04 05
CHVVP/SA 1X2X0.5
CHVVP/SA 1X2X0.5
CHVVP/SA 1X2X0.5
1 2 1 2 HLD-BNWAS 100桥楼航行
旧底图总号 SHIELD GROUND 值班报警系统系统接线图 HLD9000JX
接线缆屏蔽层
HLD-BNWAS 100 BRIDGE
标记 数量 更改单号 签名 日期 NAVIGATIONAL WATCH 版本 标记 质量 比例
底图总号 设 计 ALARM SYSTEM WIRING
审 核 DIAGRAM V1.5
INSTALLATION MANUAL
工 艺
CJEW95/SC 2X1.5
MAIN POWER
CJEW95/SC 2X1.5
DC 24V
应急电源 DC 24V
BACK UP POWER
DC 24V
日期 签名
主电源DC 24V
自动舵
标准化
北京海兰信数据科技股份有限公司
批 准
格式( ) 制图: 描图: 幅面:A3