Documente Academic
Documente Profesional
Documente Cultură
com
E-mail: sales@eastrongroup.com
Tel: +86-573-83698881 Fax: +86-573-83698883
Add: No.1369,Chengnan Rd. Jiaxing, Zhejiang, 314001, China
ISO9001:2015 MID
追求品质卓越
COMPANY INTRODUCTION
Zhejiang Eastron Electronic Co., Ltd. (Eastron) , a leading high-tech manufacturer and supplier of energy metering Persuing the excellence of quality
products and energy management solutions in China.
Quality is highly valued, Eastron strictly follows ISO9001:2015 in operation, management. Eastron has obtained the
勇攀科技高峰
MID (Measuring Instruments Directive) D from SGS for its production site. Eastron products had passed the European
MID B, CE, ROHS 2.0 authentication and complied with relevant IEC, EN, and G/B standard. With high quality products and
reliable services, Eastron has gained a good reputation among clients and partners in more than 50 countries.
As one of the most reliable suppliers of meters in China for high quality, competitive price and excellent after-sales
services, Eastron provides not only the existing products and services, we can also design and provide the products and s
ervices requested by customer. We are so proud of being favored by customers for our meters and solutions, especially Climbing the peak of Technology
for din rail energy meters, Panel power meters, Current transformers, relay and timers, Gateway and Management
Systems etc.
To meet the challenges of ever changing industry development, product design and manufacturing processes are
constantly being improved, which makes Eastron keep its competitive edge in the market. With more than 30 patented
technologies, Eastron has been awarded with the certificate of “National High-tech enterprise”.
PROFESSIONAL MANUFACTURER OF METERS
Our Mission
"Create Value to and Grow Up with Our Partners". We strive to help our customer gain commercial advantage by c
onsistently providing competitively-priced, high-quality products together with the best possible technical support.
Moreover, we pride ourselves on focusing not only our customer's short-terms requirements but also on the long-
terms needs of the marketplace.
This drives us to give the best customer service in the industry and ensure completing customer satisfaction.
What’s MID?
Conditions of application
The Measuring Instruments Directive (2014/32/EU) is a directive by the European Union, which seeks to harmonise many aspects of legal metrology across all
member states of the EU. Its most prominent tenet is that all kinds of meters which receive a MID approval may be used in all countries across the EU. In the European Union, the use of MID-certificated meters on “Private” electrical networks has been mandatory in the context of active energy billing based
on consumption reading by index differences. Typical examples include; camping sites ,holiday rentals, students accommodation, office building, shopping
centers, marinas, exhibition halls, electric vehicle recharging station, etc.
Which measuring instruments MID covers? As the MID is applicable to all European Union Member States, certification of ammeter by a Notified Body(NB) means that no other testing by a national legal
metrological service is required. So a MID certificated Eastron meter can be used as an active energy billing meter in all European Union countries.
The MID covers these measuring instruments: The Directive also imposes product certification according to the EN50470-1/-3 standards, as well as design certification (Module B) and manufacturing process
gas meters certification(Module D) by a Notified Body. In order to ensure product traceability and guarantee its metrological value, thus to protect consumers.
meters for liquids other than water
meters for liquids other than water - ancillary equipment
material measures of length
continuous totalising weighing machines
Certificates MID B +D we have:
electrical energy meters
Taximeters
measuring systems for liquids other than water Directive
automatic checkweighing and weight grading machines
hot-water meters Partial repeal
cold-water meters, as concerns clean water meters
Regulatory Context
The Measuring Instruments Directive was published on 30 April 2004 in the Official Journal of the EU, 1 2 3 7
but not applied until after 30 Oct 2006 and there is a 10-year transition period. National implementations
of the new legislation are currently in the works. The MID directive is updated by 2014/32/EU. 4 5 6
1. SDM120 Series SGS0141
2. SDM220 Series SGS0172
Directive transposed into national law of each country in 2006 3. SDM230 Series SGS0206
European directive on measuring
instruments dated 31st March 2004 4. SDM630MCT series SGS0142
2 specific European standards (EN 50470-1/EN 50470-3) for energy 5. SDM630 100A series SGS0151
meters, stipulating the particular requirements and type tests for energy meters
6.SDM72 Series SGS0213
7.Smart X96 Series SGS0288
RS 485
ROUTER
Ethernet SERVER
ESP-4
SMART X96-I SMART X96-J ESP-6 ESP-5
X203
LORA
Rs485
SMART X
Rs485
Rs485 Rs485
Solar PV Array Monitoring Solution
ESP-2
SDM120M
SDM630M
SMART X
Rs485
M-Bus
Convertor
SECT-RJ SECT-RJ
SMART X96 SERIES SMARTCONNECT X835 SMART X96 SERIES SDM630MCT-RJ SDM630MCT-2L
MID B+D DIN 96 panel mounted DIN 96 panel mounted Din rail mounted Din rail mounted
333mV/ 5A input Class 0.5S/0.2S accuracy 333mV/ 100mA input 2 three phase circuit measured
1ph/3ph network compatiable Rs485 Modbus/ Ethernet TCP True RMS measurement 333mV/ 100mA input
True RMS measurement Multi-Tariffs and RTC Rs485 MODBUS True RMS measurement
Measures 85 Important Electrical Parameters Multi-Tariff and RTC Rs485 MODBUS Alarm and SOE 2 Pulse outputs Rs485 MODBUS
2nd~63rd THD & IHD for Volatege and Current THD-i & THD-u Digital Input and outputs THD-i & THD-u 2 Pulse outputs
Alarms and SOE 2~63rd IHD-u and IHD-i
CT & PT programmable Multi-parameters measured THD-i & THD-u
Bar Graph for Power Indication Accuracy Class 0.5S/0.2S CT & PT programmable Multi-parameters measured
Multi-parameters measured
RS485 Modbus RTU Full Viewing Angles LCD Display 1p2w,3p3w,3p4w network
Ethernet Modbus TCP (as Gateway) Energy Information of Each Phase
Digital Inputs and Digital Outputs
MCS-D40
Ethernet
Voltage inputs to MCS-U or MCS-C Connection between ESCT-RJ and MCS-I Connection between MCS-I and MCS-U/C
Gateway
MCS-I31
M C S-I31
COMM COMM
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
ALARM
M C S-I31
M C S-I31
ALARM ALARM ALARM ALARM ALARM
ALARM ALARM ALARM
ON ALARM COMM ON ON ON
ON ON ON ON
ON ON
CMS-C40
Split Core 3-IN-1 combined between the CMS-I and CMS-U; between the Current Transformer
10~600A Primary 60~630A Primary CMS-U and CMS-D module. ESCT-RJ and the power meters
100mA/333mV output 100mA/333mV output with RJ12 terminal.
MCS-U20
Smaller Size
Cheaper Cost
COMM COMM
COMM COMM COMM COMM COMM
M C S-I31
COMM COMM
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
M C S-I31
ALARM
M C S-I31
M C S-I31
TX+ TX-
Rs485
MCS-U20
MCS-U20 MCS-U20
MCS-I31
ALARM
ON
ON ALARM COMM ON ALARM COMM
ESCT-RJ1
Faster Connection MCS-I3x Series MCS-Uxx Series MCS-Cxx Series MCS-Dxx Series
Current module Voltage module Communication module Display Module
ESCT-RJ1 DIN rail mounted DIN rail mounted DIN rail mounted Panel mounted
333mV input 3x230(400)V inputs 3x230(400)V inputs LCD display
1ph/3ph network compatible 1ph/3ph network compatible 1ph/3ph network compatible Graph and Curves
True RMS measurement Voltage, Frequency,THD-u Voltage, Frequency,THD-u Rs485 Modbus RTU
Current, Power, THD-i Over-voltage alarm Over-voltage alarm Ethernet TCP
CT ratio programmable Class 0.5s Class 0.5s 256M memory
Overcurrent alarm Rs485 Modbus RTU
Class 0.5s
SDM 120CTP MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, Pulse outputs 1 Module
SDM 120CT-Modbus MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, RS485 Modbus,Pulse outputs 1 Module
SDM 120CT-Mbus MID 230V / 110V ,100mV CT, 50/60Hz Multifunction, Mbus,Pulse outputs 1 Module SDM72 CT SERIES Three Phase
Model Specifications Description Size SDM72CT-BI 3X230/400V,0.25~5(6)A,50/60Hz Import / Export kWh,Power(W),Energy Resettable,Pulse outputs 4 Modules
SDM220Modbus MID 230V/110V,0.25~5(100)A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 2 Modules SDM72CTM 3X230/400V,0.25~5(6)A,50/60Hz Import / Export kWh,Power,RS485 Modbus, Pulse outputs 4 Modules
SDM220MT MID 230V,0.25~5(100)A,50/60Hz 4 tariffs, Multifunction, RS485 Modbus, Pulse outputs 2 Modules
SDM220Pulse MID 230V/110V,0.25~5(100)A,50/60Hz Multifunction, Pulse outputs 2 Modules SDM630 100A SERIES Three Phase
SDM220Standard MID 230V,0.25~5(100)A,50/60Hz Import/ Export kWh, RS485 Modbus, Pulse outputs 2 Modules
Model Specifications Description Size
SDM630Pulse MID 3X230/400V,0.5~10(100)A,50/60Hz Multifunction, Pulse outputs 4 Modules
SDM230 SERIES Single Phase SDM630Standard MID 3X230/400V,0.5~10(100)A,50/60Hz Import /Export kWh, RS485 Modbus,Pulse outputs 4 Modules
Model Specifications Description Size SDM630Mbus MID 3X230/400V,0.5~10(100)A,50/60Hz Multifunction, Mbus,Pulse outputs 4 Modules
SDM230A 230V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 2 Modules SDM630MT MID 3X230/400V,0.5~10(100)A,50/60Hz Multi-tariffs (RTC), Multifunction, RS485 Modbus 4 Modules
SDM230D 230V/110V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 2 Modules SDM630-2T 3X230/400V,0.5~10(100)A,50/60Hz 2tariffs(Time-relay), Multifunction, RS485 Modbus 4 Modules
SDM230DR MID 230V,0.5~10(100)A,50/60Hz Energy(kWh) and Power(W),Energy Resettable, Pulse output 2 Modules
SDM230Bi MID 230V,0.5~10(100)A, 50/60Hz Import /Export kWh,Power(W),Energy Resettable,Pulse outputs 2 Modules
SDM230Modbus MID 230V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 2 Modules SDM630 MCT SERIES Three Phase
SDM230Mbus MID 230V,0.5~10(100)A,50/60Hz Multifunction, Mbus,Pulse outputs 2 Modules
SDM230Pulse MID 230V,0.5~10(100)A,50/60Hz Multifunction, Pulse outputs 2 Modules Model Specifications Description Size
SDM230Standard MID 230V,0.5~10(100)A,50/60Hz Import / Export kWh, RS485 Modbus,Pulse outputs 2 Modules SDM630MCT MID 3X230/400V,1A or 5A,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 4 Modules
SDM230-2T MID 230V,0.5~10(100), 50/60Hz 2 tariffs, Multifunction, RS485 Modbus,Pulse output 2 Modules SDM630MCT-Mbus MID 3X230/400V,1A or 5A,50/60Hz Multifunction, Mbus, Pulse outputs 4 Modules
SDM230-LoRa 230V,0.5~10(100), 50/60Hz Multifunction, LoRa Communication,Pulse output 2 Modules SDM630MCT-2T MID 3X230/400V,1A or 5A,50/60Hz 2 Tariffs, Multifunction , Mbus, Pulse outputs 4 Modules
SDM630MCT-MV 3X230/400V, 333mV CT,50/60Hz Multifunction, RS485 Modbus, Pulse outputs 4 Modules
SDM630MCT-RJ 3X230(400)V,100mA or 333mV CT,50/60Hz Plug-in Solution ,Multifunction, RS485 Modbus , Pulse outputs 4 Modules
SDM320 SERIES Single Phase SDM630MCT-2L 3X230(400)V,100mA or 333mV CT,50/60Hz Dual-load, Multifunction, RS485 Modbus 4 Modules
SDM630MCT-LoRa 3X230(400)V,100mA or 333mV CT,50/60Hz Multifunction, LoRa Communication, Pulse outputs 4 Modules
Model Specifications Description Size
SDM320D 230V,0.5~10(100)A,50/60Hz Energy(kWh), Pulse output 4 Modules
SDM320E 110/220V,0.5~10(100)A,50/60Hz Energy(kWh) , Pulse output 4 Modules SDM630 2C SERIES Three Phase
SDM320M 230V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 4 Modules
SDM320EM 110/220V,0.5~10(100)A,50/60Hz Multifunction, RS485 Modbus,Pulse outputs 4 Modules Model Specifications Description Size
SDM630 CT-2C 3X230(400)V,1A or 5A,50/60Hz Dual load Multifunction, RS485 Modbus,Pulse outputs 6 Modules
SDM630MV-2C 3X230(400)V,333mV CT ,50/60Hz Dual load Multifunction, RS485 Modbus,Pulse outputs 6 Modules
Smart Connect X72 A 1A /5A CT , 50/60Hz 3 Phase current; RS 485 Modbus Class 0.5s/0.2s
Smart Connect X72 V 3x230(400)V , 50/60Hz 3 PhaseVoltage; RS 485 Modbus Class 0.5s/0.2s
Prepay Energy Meter
Smart Connect X72 W 3x230(400)V AC, 5A CT, 50/60Hz 3 Phase current ,Voltage and Power; RS 485 Modbus Class 0.5s/0.2s
Smart Connect X835 A 1A /5A CT , 50/60Hz 3 Phase current; RS 485 Modbus Class 0.5s/0.2s
Model Specifications Description Smart Connect X835 V Class 0.5s/0.2s
3x230(400)V , 50/60Hz 3 PhaseVoltage; RS 485 Modbus
MCS-I30 3x CT operated RJ12 input Current , power, energy
Smart Connect X835 W 3x230(400)V AC, 5A CT, 50/60Hz 3 Phase current ,Voltage and Power; RS 485 Modbus Class 0.5s/0.2s
M C S-U20
COMM COMM
MCS -I31
MCS -I31
MCS -I31
MCS -I31
MCS -I31
MCS -I31
ALARM
MCS -I31
MCS -I31
MCS-D40 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; SMART X96 SERIES Three Phase
MCS-D50 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; Ethernet
MCS-D60 230V ac. / 24V dc. Aux. supply Graphic display ; Rs485 Modbus; Ethernet; 256Mhz Memory Model Specifications Descriptions Accuracy
3x230/400V, 100mA , 50Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-1 MID
RS 485 Modbus; 2 Pulse outputs; 2~63rdTHD; self-power supply; Class 1.0 / 0.5s
3P4W, 3P3W, 2P3W, 1P2W
3x230/400V, 1A /5A , 50Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-5A MID
3P4W, 3P3W, 2P3W, 1P2W RS 485 Modbus; 2 Pulse outputs; 2~63rdTHD; self-power supply; Class 1.0 / 0.5s
ESP-7 SERIES Converter
3x230/400V, 1A /5A , 50/60Hz 85 electric parameters measured; CT & PT programmable;
Smart X96-5F RS 485 Modbus; 2~63rdTHD; Aux. power supply; Class 1.0 / 0.5s / 0.2s
3P4W, 3P3W, 2P3W, 1P2W
Model Input Output Power supply Smart X96-5G Same as Model“ F” Model“ F ”+ 4 Digital Inputs and 2 Digital outputs Class 1.0 / 0.5s / 0.2s
ESP-7100 RS 485; 1200~38400bps LoRa 470/433Mhz 9~24V DC, 2W Smart X96-5H Same as Model“ F” Model“ F ”+ Ethernet port Class 1.0 / 0.5s / 0.2s
ESP-7110 RS 485 ; 1200~38400bps Ethernet TCP 9~24V DC, 2W Smart X96-5I Same as Model“ F” Model“ F ”+ Ethernet port + 4 digital inputs and 2 Digital outputs Class 1.0 / 0.5s / 0.2s
ESP-7120 RS 485 ; 1200~38400bps Wifi IEEE802.11b/g/n 9~24V DC, 2W Model“ F ”+ Ethernet Gateway (RTU toTCP)
Smart X96-5J Same as Model“ F” Class 1.0 / 0.5s / 0.2s
+ 4 digital inputs and 2 Digital outputs
Smart X96-Lora Same as Model“ F” Model“ F ”+ Lora Communication Class 1.0 / 0.5s / 0.2s
Pm1000 SERIES Single Phase ESAC PM200 SERIES Moving lron Movement
PM1500-W 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96
PM1500-C 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus A/V : 0.5%; Hz: 0.02 48x96, 72x72, 96x96 ESAC PM500 SERIES Moving Coil Movement
PM1500-M 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 48x96, 72x72, 96x96
PM3000-Hz 45~66Hz 0.02Hz 72x72, 96x96 ESAC PM600 SERIES Moving Coil Movement
PM3000-W 0~600V AC; 1A/5A CT input 0.5% 72x72, 96x96
PM3500-V 0~600V AC; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 72x72, 96x96
PM3500-Hz 45~66Hz; 2xDI; 2x DO; RS485 Modbus 0.02Hz 72x72, 96x96 ESAC PM700 SERIES Moving Coil Movement
PM3500-PF 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.02Hz 72x72, 96x96
PM3500-W 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 0.5% 72x72, 96x96
Model Measurement Range Accuracy Size
PM3500-Var 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 1x AO; RS485 Modbus 1% 72x72, 96x96
PM700-Hz 45 ~ 55 Hz ; 45 ~ 65 Hz ; 55 ~ 65 Hz 1.5 72x72, 96x96
PM3500-C 0~600V AC; 1A/5A CT input; 2xDI; 2x DO; 3x AO; RS485 Modbus A/V : 0.5%; Hz: 0.02 72x72, 96x96
PM700-PF 0.5 lead ~ 1.0 ~ 0.5 Lag ; 110V / 220V / 380V / 415V 2.5 72x72, 96x96
PM3500-M 0~600V AC; 1A/5A CT input; 4xDI; 2x DO; 2x AO; RS485 Modbus 0.5% 72x72, 96x96
Model Input Output Power supply Model Primary Current Secondary Output Accuracy
ESP-2100 RS232/485/422 x1; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 350W ESCT-RJ335 60~250A 333mV / 100mV / 100mA 0.5 / 1
ESP-2200 RS232/485/422 x2; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W ESCT-RJ345 250~630A 333mV / 100mV / 100mA 0.5 / 1
ESP-2400 RS232/485/422 x4; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 4W
ESP-2800 RS232/485/422 x8; 1200~115200bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W
ESP-2120 M-Bus EN13757-3; 300~9600bps Ethernet TCP 10/100 Mbps 9~24V DC, 6W ESCT-SC SERIES 3-in-1
ESCT-U SERIES Split Core ESRD TMS SERIES Digital multifunction time relay
ESCT-U300 400,800,1000,1500,2500,3000,5000A 333mV 0.5 / 1 ESRD TPA SERIES Single channel astronomical time switch
ESRD-TPA1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
Model Primary Current Secondary Output Accuracy
ESCT-RC60 100A 333mV / 100mV 0.5 / 1
ESCT-RC76 200A 333mV / 100mV 0.5 / 1 ESRD TPW SERIES Digital weekly time switch
ESCT-RC90 400A 333mV / 100mV 0.5 / 1
ESCT-RC100 800A 333mV / 100mV 0.5 / 1
Model Specifications Description Size
ESCT-RC150 1000A 333mV / 100mV 0.5 / 1
ESRD-TPW1 AC220-240V,50/60Hz Single Channel,40 programs, LCD display, Holiday mode, Automatic 2 Module
ESCT-RC160 1200A 333mV / 100mV 0.5 / 1
ESRD-TPW2 AC/DC24-264V,50/60Hz Double Channel,100 programs, Backlit, LCD , Holiday mode, Automatic 2 Module
ESCT-RC190 3000A 333mV / 100mV 0.5 / 1
ESCT-RC200 5000A 333mV / 100mV 0.5 / 1
ESCT-RC300 6000A 333mV / 100mV 0.5 / 1
ESRD ST SERIES Twilight switch
ESRS-TM12 A1-A2:AC220V; A3-A2; AC/ DC24V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
ESCT-DM SERIES Solid Core
ESRS-TM14 AC/DC 12-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
ESRS-TM23 AC/DC 24-240V,50/60Hz 10 operating modes,10 time ranges, LED indication 1 Module
Model Primary Current Secondary Output Accuracy
ESCT-DM20/30 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESCT-DM20/35 50,60,75,80,100,125,150,200,250,300 A 5A 1
ESRS TSL SERIES Staircase light timer
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0·5%
Operational voltage 80%~120% of Un Frequency 0·2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120 Modbus / Mbus/Pulse - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 45A Active energy (Wh) Class 1
45A direct load Operational current range 0.4% Ib-Imax
One module 17.5mm wide Over current withstand 30 Imax for 0.01s Modbus
Measuring kWh,W, V, A, PF, Hz, dmd.etc. Operational frequency range 50 / 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps
1-247
RS485 Modbus or M-bus communication Max reading 999999 kWh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120-45A series are advanced single phase energy monitoring solution with built-in configuration push button and LCD data displaying, Primary Address 1 to 250
Degree of pollution 2
particularly indicated for energy and other parameters metering and for cost allocation. Housing for DIN-rail mounting, IP51 protection degree, Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
direct connection up to max 45A. Moreover the meter can be provided with a pulses output proportional to the active energy being measured
Insulating encased meter of protective class II
and a RS485 output/ M-bus output port for remote monitoring. It is an ideal choice as a sub-meter for AMR system or SCADA system.
Aititude up to 2000m Pulse output
Electrostatic discharges 8kV contact / 15kV air gap Pulse outputs 2
This series has been assessed and certified as meeting the requirements of EC Directive 2014/32/EU. Electromagnetic HF fields IEC 61000-4-3 Pulse output type Passive
The EC Type Examination Certificate Number is 0120/SGS0141. Electrical fast transients 4kV Configurable
Pulse Output 1
Surge 4kV Pulse width 200/100(default)/60ms
Radiated & conducted emissions EN 55022 Pulse output 2 1000imp/kWh
SDM120 —M—1—1
17
.5
m
m
MBUS 1 MBUS 2
SDM120Mbus
P: Multi-parameters, 2 Pulse outputs
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication
G B A
120Modbus
62mm
1: 110V/120V AC
2: 220V/230V AC
35mm
1: MID
2: Non-MID Height 119mm
Width 17.5mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM120CT Modbus / Mbus / Pulse - AC voltage withstand
- Impulse voltage withstand
4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Primary current 5~9999A Reactive energy(Varh) Class 2
Secondary input 100mV or 100mA Active energy (Wh) Class 1
CT operated Over current withstand 20 Imax for 0.01s
One module 17.5mm wide Operational frequency range 50 or 60Hz Modbus
Internal power consumption ≤ 2W/10VA
Measuring kWh,W, V, A, PF, Hz, dmd. etc. Bus type RS485(semi-duplex)
Pulse output 1 configurable
Bi-directional measurement Protocol Modbus RTU
Pulse output 2 1000imp/kWh
2 Pulse outputs MID Display LCD with backlight
Baud rate
Address range
1200/2400/4800/9600bps
1-247
RS485 Modbus or M-bus communication Max reading 999999 kWh
Max. Bus loading 64pcs
Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM120 CT series is CT operated type single phase multi-function energy meter. The meter is compactly designed in one module din rail enclosure. Primary Address 1 to 250
LCD display is provided to show the energy and other important electric parameters measured. Moreover the meter can provide with pulse outputs Degree of pollution 2
Secondary Address 00 00 00 01 to 99 99 99 99
proportional to the energy being measured and a RS485 output/ M-bus output port for remote monitoring. CT ratio can be set, which enables this P rotection against penetration of dust and water IP51(indoor)
meter to measure big current load. II
Insulating encased meter of protective class
Aititude up to 2000m
This series has been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. Electrostatic discharges 8kV contact / 15kV air gap
The EC Type Examination Certificate Number is 0120/SGS0141. IEC 61000-4-3
Electromagnetic HF fields
Electrical fast transients 4kV
Surge 4kV
Radiated & conducted emissions EN 55022
SDM120—CT—M—1—1
G B A
P: Multi-parameters, 2 Pulse outputs SDM120CT-Modbus
M:Multi-parameters, 2 Pulse outputs + RS485 Modbus RTU
MB: Multi-parameters, 2 Pulse outputs + M-Bus Communication
MBUS 1 MBUS 2
SDM120CT-Mbus
62mm
1: 110V/120V AC
2: 220V/230V AC
35mm
1: MID
2: Non-MID
S2
P1
Height 119mm
Width 17.5mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
2 1 GND B A
SDM220 —M—1—1
4 5 6 7 8 9 PULSE OUTPUT RS485 PORT
P : Multi-parameters,2 Pulse outputs SDM220-Modbus 45m
m
Std: kWh,2 Pulse outputs, RS 485 Modbus 4 5 6 7 8 9 SDM220-MT
M: Multi-parameters,2 Pulse outputs, Modbus
MB: Multi-parameters,2 Pulse outputs, M-Bus
MT:: Multi-parameters,2 Pulse outputs,4 Tariffs, Modbus 2 1
47mm
PULSE OUTPUT
1:110/120V SDM220-Pulse
62 mm
2:220/230V 4 5 6 7 8 9
1: MID
2 1 BUS1 BUS2
2: Non-MID
mm
1 2 3 35
PULSE OUTPUT MBUS PORT mm
90
m
6m
SDM220-Mbus
4 5 6 7 8 9
3
100A
L IN L OUT Height 90mm
N Width 36mm
Depth 62mm
Specification Accuracy
Nominal voltage(Un) 120V or 230V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM 230 Modbus / Mbus / 2T / Std / Pulse - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
SINGLE PHASE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 5A Reactive energy(Varh) Class 2
Maximum rated current (Imax) 100A Active energy (Wh) Class 1
100A direct load Operational current range 0.4% Ib-Imax
2 Module 36mm wide Over current withstand 30 Imax for 0.01s Modbus
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Operational frequency range 50 or 60Hz
Bus type RS485(semi-duplex)
Internal power consumption ≤ 2W/10VA
Bi-directional measurement Protocol Modbus RTU
Pulse output 1 1000imp/kWh
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs Pulse output 2 1000imp/kWh(only for SDM230DR/Bi)
Address range 1-247
RS485 Modbus or M-bus communication Max reading 999999.9 kWh
Max. Bus loading 64pcs
2 Tariffs available MID Communication distance 1000M
Performance criteria Parity EVEN/ODD/NONE
Operating humidity ≤ 90% Data bit 8
Storage humidity ≤ 95% Stop bit 1
Operating temperature -25°C - +55°C
Storage temperature -40°C - +70°C
23°C± 2°C
M-bus
Reference temperature
Bus type M-bus
International standard IEC 62053-21 / EN50470-1/3
Protocol EN13757-3
Accuracy class Class1/Class B
Baud rate 300/600/1200/2400/4800/9600
Installation category CAT II
Introduction Mechanical environment M1
Parity NONE/EVEN/ODD
Stop bits 1 or 2
Electromagnetic environment E2
SDM230 series is an advanced digital single phase multi-function energy meter, which measures up to 100A direct load. The unit measures active Primary Address 1 to 250
Degree of pollution 2
energy, reactive energy, current, voltage, power, power factor, frequency, demand, etc. Bi-directional measurement makes this unit an ideal choice Secondary Address 00 00 00 01 to 99 99 99 99
P rotection against penetration of dust and water IP51(indoor)
for Solar PV measurement. A remote communication port is provided, RS485 Modbus RTU or M-bus EN13757-3 and Communication parameters are
Insulating encased meter of protective class II
password protected in setup mode. User can check data and set up the meter via the buttons on the front panel. SDM230-2T can measure energy from
two different power supplies. Electrostatic discharges 8kV contact / 15kV air gap Pulse Output
Electromagnetic HF fields IEC 61000-4-3 Pulse outputs 2
This Series has been assessed and certified as meeting the requirements of EC Directive 2004/22/EC. Electrical fast transients 4kV Pulse output type Passive
The EC Type Examination Certificate Number is 0120/SGS0206. Surge 4kV Pulse Output 1 Configurable
Radiated & conducted emissions EN 55022 Pulse width 200/100(default)/60ms
Pulse output 2 1000imp/kWh
230V/2T 45mm
63mm
1:110/120V
A B GND 1+ COM 2+
SDM230Modbus
2:220/230V
5 6 7 8 9 10
1: MID SDM230Mbus
2: Non-MID Mbus1 Mbus2 1+ COM 2+ 36
5 6 7 8 9 10
m
m 35mm
99mm
B:Class 1 5 6 7 8 9 10
3 4 Height 99mm
Width 36mm
N-in N-out
Depth 63mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM530 Modbus / Mbus / MT - AC voltage withstand 4KV for 1 minute Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand 6KV-1.2µS Reactive power ±1% of range maximum
THREE PHASE 4 WIRE MULTI-FUNCTION ENERGY METER
Basic current (Ib) 10A Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
100A direct load Over current withstand 30 Imax for 0.01s
7 Module wide Operational frequency range 50 or 60Hz
Modbus
Power consumption per phase ≤ 2W/10VA
Multi-measurement:kWh,kVarh,W,Var,VA,PF,Hz,dmd,V,A,etc. Bus type RS485(semi-duplex)
Display LCD
Bi-directional measurement Protocol Modbus RTU
Max reading 999999.99 kWh/kVarh
Baud rate 1200/2400/4800/9600bps
2 Pulse outputs
Address range 1-247
RS485 Modbus or M-bus communication Performance criteria Max. Bus loading 64pcs
Operating humidity ≤ 90%
Multi-tariffs Communication distance 1000M
Storage humidity ≤ 95%
Parity EVEN/ODD/NONE
Operating temperature -25°C - +55°C
Data bit 8
Storage temperature -40°C - +70°C
Stop bit 1
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3
Accuracy class Class1/Class B M-bus
Installation category CAT III Bus type M-bus
Mechanical environment M1 Protocol EN13757-3
Electromagnetic environment E2 Baud rate 300/600/1200/2400/4800/9600
Introduction Degree of pollution 2 Parity NONE/EVEN/ODD
P rotection against penetration of dust and water IP51(indoor) Stop bits 1 or 2
The SDM530 100A series measure and display the characteristics of three phase four wires(3p4w) supplies, including voltage, frequency, current, Primary Address 1 to 250
Insulating encased meter of protective class II
power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVArh. Maximum demand current can be measured 00 00 00 01 to 99 99 99 99
Electrostatic discharges 8kV contact / 15kV air gap Secondary Address
over preset periods of up to 60 minutes. In order to measure energy, the unit requires voltage and current inputs in addition tot he supply required
Electromagnetic HF fields IEC 61000-4-3
to power the product.
Electrical fast transients 4kV Pulse Output
SDM530 100A series support max.100A direct connection, save the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective Pulse outputs 2
and easy operation. Built-in interfaces provides pulse and RS485 Modbus RTU outputs/ Mbus Port. All the configuration are password protected. Pulse output type Passive
Multi-tariff
time clock accuracy ﹤1s/day Pulse Output 1 Configurable
Tariff 4 Pulse width 200/100(default)/60ms
Time segments 10 Pulse output 2 400imp/kWh
SDM530—M—4—4—C
65mm
49mm
1: 127/220V
2: 230/400V SDM530Modbus/MT
1: Single tariff 1 2 3 4 5 6 7
BUS1 BUS2
2: 2 Tariffs 2 1
10
35
mm
4: 4 Tariffs 0m
m
mm
125
L1
B:Class 1 24 23 22 21 20 19
L2
C: Class 0.5s SDM530Mbus
D: Class 0.2s L3
N Height 100mm
Width 125mm
Depth 65mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM530CT—M—4—4—C
L1 L2 L3 N
65mm
49mm
1: 127/220V
2: 230/400V SDM530CT-Modbus/MT
1: Single tariff 1 2 3 4 5 6 7
BUS1 BUS2 35
2: 2 Tariffs 2 1
10
mm
0m
4: 4 Tariffs m
mm
125
L1 S1
24 23 22 21 20 19 P1
B:Class 1 L2
S1
C: Class 0.5s SDM530CT-Mbus P1
S1
L3
D: Class 0.2s P1
N
Height 100mm
Width 125mm
Depth 65mm
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
1: Single tariff
2: 2 Tariffs
4: 4 Tariffs
5 6 7 8 5 6 7 8 5 6 7 8
1: MID 72 35m
m
m mm
2: Non-MID m 100
L1 L2 L3 N L1 L3 L2 L1 N
B:Class 1
C: Class 0.5s
D: Class 0.2s SDM630Modbus SDM630Pulse SDM630Mbus Height 100mm
SDM630Standard Width 72mm
SDM630MT
Depth 66mm
SDM630-2T
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM630 CT Series have been assessed and certified as meeting the requirements of EC Directive 2014/32/EU. The instrument traceable number is 0120/SGS0142
SDM630MCT
SDM630MCT-MV
SDM630MCT—5—J—2—4—1—C
1: 100mA
2: 100mV
SDM630MCT-2T
3: 333mV M:Modbus
5: 1A & 5A MB: M-Bus
L: LoRa
W: Wifi
1: Self-power supply
2: Aux. AC power supply
SDM630MCT-Mbus Height 94.5mm
3: Aux. DC power supply 1: Single tariff Width 72mm
2: 2 Tariffs Depth 65mm
4: 4 Tariffs
1: MID
2: non-MID B:Class 1
C: Class 0.5s
D: Class 0.2s
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 60%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
S1
P1
S1
P1
L2
P1 P1
Rj12 socket for S1 S1
L3
fast connection and to P1 P1
L1
L2 1 2 3 4
L3 Height 94.5mm
N MEASURED VOLTAGE
Width 72mm
The example shows a wiring in 3p4w network. 3 PHASE 4 WIRE Depth 65mm
Plug-in terminals for voltage inputs.
Self power supply from L1.
Specification Accuracy
Nominal voltage(Un) 3x230/400 V ac Voltage,Current 0 · 5%
Operational voltage 80%~120% of Un Frequency 0 · 2% of mid-frequency
Insulation capabilities Power factor 1% of unity (0.01)
SDM630-2C - AC voltage withstand 4KV for 1 minute
6KV-1.2µS
Active power , Apparent power ±1% of range maximum
- Impulse voltage withstand Reactive power ±1% of range maximum
DUAL LOAD MULTI-FUNCTION ENERGY METER Rated current (Ir) 5A or 333mV CT input Reactive energy(Varh) Class 2
Operational current range 0.4% Ib-Imax Active energy (Wh) Class 1
Over current withstand 20 Imax for 0.01s
2 Meters in 1
Operational frequency range 50 or 60Hz
Easy and error free connection ≤ 2W/10VA Modbus
Power consumption per phase
5A / 333mV CT input Pulse output Configurable Bus type RS485(semi-duplex)
Multi-parameter measured Display LCD Protocol Modbus RTU
Max reading 9999999.9 kWh/kVarh Baud rate 2400/4800/9600/19200/38400 bps
RS485 Modbus RTU
Address range 1-247
2 Pulse outputs
Max. Bus loading 64pcs
Performance criteria Communication distance 1000M
Operating humidity ≤ 90% Parity EVEN/ODD/NONE
Storage humidity ≤ 95% Data bit 8
Operating temperature -25°C - +55°C Stop bit 1
Storage temperature -40°C - +70°C
Reference temperature 23°C± 2°C
International standard IEC 62053-21 / EN50470-1/3 Pulse Output
Accuracy class Class1/Class B Pulse outputs 2
Installation category CAT III Pulse output type Passive
Introduction Mechanical environment M1 Pulse Output 1 C1 Configurable
Electromagnetic environment E2 Pulse output 2 C2 Configurable
The SDM630-2C is a dual load three phase 4 wire multi-function energy meter for measuring energy consumption in split load applications such as Power and lighting loads. The meter Degree of pollution 2 Pulse width 200/100(default)/60ms
measures 2 three phase circuits separately and display the parameters including voltage, current, power, power factor, frequency, demand, active energy, reactive energy etc. P rotection against penetration of dust and water IP51(indoor)
Insulating encased meter of protective class II
Electrostatic discharges 8kV contact / 15kV air gap
The meter connect with 3-in-1 CT via wiring looms for plug-in connection. It is a cost-effective and space saving solution for all new power and lighting, or dual load, distribution and
Electromagnetic HF fields IEC 61000-4-3
panel boards. ESCT-SC series current transformer provides a range of CT with primary current up to 630A.
Electrical fast transients 4kV
Surge 4kV
Radiated & conducted emissions EN 55022
Circuit 2
Current connection cable between CT3
Circuit 1
CT3
65mm
CT2
CT1
L32 L31 L22 L21 L12 L11 L32 L31 L22 L21 L12 L11
m
Voltage input - --- 1 - --- 2 - RS485 10 35m
--
- --
-
5m
ESCT-SC N L3 L2 L1 - - - B A m m
-
GND
92m
1A fast blow fuses
L1 N L3 L2 L1 Height 92mm
Voltage connection cable between L2
L3 SDM630MCT-2C, SDM630MV-2C Width 105mm
network and the meter N Depth 65mm
Nominal voltage(Un) 120V or 230V ac D: LCD Display, kWh Operational voltage 80%~120% of Un
DB: LCD Display with Backlit, kWh A: Analog Register
Operational voltage 80%~120% of Un Insulation capabilities D: LCD Display
Performance criteria 1 2
63mm
Radiated & conducted emissions EN 55022
Radiated & conducted emissions EN 55022
62mm
Description
Description Buttons
Specification Specification
Model SDM 230DR / SDM230BI Model SDM320D
Display LCD with Backlit Nominal voltage(Un) 230V ac / 110V ac SDM320 —D—1—1
SDM230 —DR—1—1
Nominal voltage(Un) 120V or 230V ac Operational voltage 80%~120% of Un
Operational voltage 80%~120% of Un Insulation capabilities A: Analog Register
DR: kWh + kW, Resettable Energy, Pulse output - AC voltage withstand
Insulation capabilities 4KV for 1 minute D: LCD Display
BI: Import/export/total kWh and Power,
- AC voltage withstand 4KV for 1 minute resettable Energy,Pulse putput - Impulse voltage withstand 6KV-1.2µS
Basic current (Ib) 1: Without Backlight
- Impulse voltage withstand 6KV-1.2µS 10A
1:110/120V 2: With Backlight
Basic current (Ib) 10A 2:220/230V Maximum rated current (Imax) 100A
Maximum rated current (Imax) 100A Operational current range 0.4% Ib-Imax 1: 110V/1200V AC
1: MID
Operational current range 0.4% Ib-Imax Over current withstand 30 Imax for 0.01s 2: 220V/230V AC
2: Non-MID
Over current withstand 30 Imax for 0.01s Operational frequency range 50 or 60Hz
Operational frequency range 50 or 60Hz Internal power consumption ≤ 2W/10VA
Internal power consumption ≤ 2W/10VA Pulse output 1600imp/kWh Wiring diagrams
Pulse output 1 1000imp/kWh Display LCD
Pulse output 2 1000imp/kWh Max reading 99999.99 kWh
Max reading 999999.9 kWh
Wiring diagrams Terminals 5 & 6: Pulse output
Performance criteria 8 7 6 5
M1
5 6 7 8 9 10
Electromagnetic environment E2
Mechanical environment Dimensions
Electromagnetic environment E2 Degree of pollution 2
Electrostatic discharges 8kV contact / 15kV air gap Electrostatic discharges 8kV contact / 15kV air gap
MECHANICS MECHANICS
63mm
Din rail dimensions 99x36x63 (WxHxD) DIN 43880 Din rail dimensions 76x100x66 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 100mm
Sealing IP51 (indoor) Sealing IP51 (indoor) Width 76mm
Material self-extinguishing UL94V-0 Depth 66mm
Material self-extinguishing UL94V-0 36
m
m 35mm
99mm
Description Description
Specification Specification
Model SDM320E Model SDM530D / SDM530D-2T
Nominal voltage(Un)
SDM320 —E—1—1 Nominal voltage(Un) 3x230/400 V ac or 3x127/220 V ac SDM530 —A—1—1
110/220 V ac or220/380V ac
Operational voltage 80%~120% of Un Operational voltage 80%~120% of Un
Insulation capabilities E: Single Phase 3 Wire Insulation capabilities A: Analog Register, kWh
D: LCD Display, kWh
- AC voltage withstand 4KV for 1 minute - AC voltage withstand 4KV for 1 minute
1: Without Backlight D2T: LCD Display, kWh, Double Tariff
- Impulse voltage withstand 6KV-1.2µS - Impulse voltage withstand 6KV-1.2µS
2: With Backlight
Basic current (Ib) 10A Basic current (Ib) 10A 1: Without Backlight
Maximum rated current (Imax) 1: 110V/220V AC Maximum rated current (Imax) 100A 2: With Backlight
100A
2: 220V/380V AC
Operational current range 0.4% Ib-Imax Operational current range 0.4% Ib-Imax
1: 127V/220V
Over current withstand 30 Imax for 0.01s Over current withstand 30 Imax for 0.01s
2: 230V/400V
Operational frequency range 50 or 60Hz Wiring diagrams Operational frequency range 50 or 60Hz
Internal power consumption ≤ 2W/10VA Power consumption per phase ≤ 2W/10VA
Pulse output 1600imp/kWh Pulse output 800imp/kWh
LCD
Wiring diagrams
Display LCD Display
N-in N-out
65mm
49mm
Mechanics
Mechanics 35
Din rail dimensions 76x100x66 (WxHxD) DIN 43880 10
0m
mm
m
Mounting DIN rail 35mm Din rail dimensions 100x125x65 (WxHxD) DIN 43880 125
mm
CT operated CT operated
4 Module wide 4 Module wide
Measures active energy(kWh)+ power(W) Measures active energy(kWh)+ power(W)
SDM72CT-D/DR/BI Bi-directional measurement
SDM72CT-M Bi-directional measurement
Resettable energy THREE PHASE 4 WIRE ENERGY METER Resettable energy
THREE PHASE 4 WIRE ENERGY METER
Pulse output RS485+Pulse output
5A
BI: “DR” + Import and export energy
Basic current (Ib) 5A Parity EVEN/ODD/NONE
Basic current (Ib) DM: “BI” + RS 485 Modbus
50 or 60Hz
C: Class 0.5s
Operational frequency range 50 or 60Hz
Operational frequency range
≤ 2W/10VA Power consumption per phase ≤ 2W/10VA
Power consumption per phase
Pulse output 1000imp/kWh Pulse output 1000imp/kWh Description
LCD Display LCD
Display
999999.9 kWh Max reading 999999.9 kWh
Max reading
SDM72—CT—D—1—B
≤ 95% Storage humidity ≤ 95% BI: “DR” + Import and export energy
Storage humidity DM: “BI” + RS 485 Modbus
-25°C - +55°C Operating temperature -25°C - +55°C
Operating temperature
1:110/220V
-40°C - +70°C Storage temperature -40°C - +70°C
Storage temperature 2:230/400V
IEC 62053-21 / EN50470-1/3 International standard IEC 62053-21 / EN50470-1/3 C: Class 0.5s
International standard
Class1/Class B Accuracy class Class1/Class B
Accuracy class
Installation category CAT III Wiring diagrams
Installation category CAT III
M1 Mechanical environment M1
Mechanical environment
E2 Electromagnetic environment E2
Electromagnetic environment RS485
2 Degree of pollution 2 9 10 11 12 13 14
Degree of pollution
P rotection against penetration of dust and water IP51(indoor) G B A
P rotection against penetration of dust and water IP51(indoor)
II Insulating encased meter of protective class II
Insulating encased meter of protective class
Electrostatic discharges 8kV contact / 15kV air gap Dimensions Electrostatic discharges 8kV contact / 15kV air gap
Mechanics Dimensions
Mechanics
Din rail dimensions 100x125x65 (WxHxD) DIN 43880 Din rail dimensions 100x125x65 (WxHxD) DIN 43880
Mounting DIN rail 35mm Mounting DIN rail 35mm Height 94.5mm
Material self-extinguishing UL94V-0 Width 72mm
Material self-extinguishing UL94V-0
Height 94.5mm Depth 65mm
Width 72mm
Depth 65mm
Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 A Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 100mA / 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Measures kWh, kVarh, kW, kVar, kVA, P, F, PF, Hz, dmd, V, A, etc. Max. continuous input overload current 120% of nominal Altitude 3000m
Bi-directional Measurement IMP & EXP Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Energy Information of Each Phase
Total Harmonic Distortion of Voltage and Current Power supply Outputs
2nd~63rd Individual Harmonic Distortion Operating range Self powered (from any of the three phases) Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
RS485 Modbus RTU & Two Pulse Outputs Supply burden < 2W / 10 VA Contact Rating current 2-27mA at 27V DC
Bar Graph for Power Indication Contact Rating voltage 5-27V DC
Three phase self-power supply Accuracy Pulse Width 60 / 100 / 200 ms
Voltage (V) 0.5% of range maximum Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
Backlit LCD Display for Full Viewing Angles
MID Current (A) 0.5% of range maximum Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
Accuracy Class 0.2S /0.5S /1.0
Frequency (Hz) 0.2% of mid-frequency Communications Modbus RTU (RS485)
Plug-in Play solution
Power factor (PF) 1% of unity (0.01) Type 2-wire half duplex
Active power (W) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Reactive power (VAr) 1.0% of range maximum Address 1 to 247
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) Class 0.5S IEC62053-22
Introduction Class 1.0 IEC62053-21 Enclosure
Enclosure Style DIN 96 panel mount
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
The Smart X96 digital smart meter from Eastron is an ideal solution for the measurement and display of all important electrical parameters including Dimensions 96x96x62 mm
THD 2% to 63rd harmonic
harmonic distortion of total and individual, up to 63rd. The meter uses a high definition screen with programmable backlight for high visibility in Panel cut-out 92x92mm
dark area and from all viewing angles. New sector icons shows the percentage of the power load on 3 phases. Modbus RS485 RTU and 2 pulse outputs Panel thickness 1-2 mm
Measured Range
are equipped as standard. Protection rating Ip51 (Indoor)
Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
Material UL 94-VO
Current (A) 5 – 120% of nominal
The Smart X96 and 3-in-1 Current transformers provide a simple and fast installation solutions. With pre-cut wiring looms, the meters and CTs can be Weight 340 g
Frequency (Hz) 45– 66 Hz
easily connected. This solution reduces lot of wiring and installation time, and save wrong wiring troubles. Cable size 0.05mm-4mm stranded wire
Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
Terminals Voltage: Shrouded screw-clamp. Current: RJ12
Energy 8digit, upto 9999999.9 kWh
Power factor 4 quadrant
THD 0 – 40% upto 63rd harmonic
2P1+
CO
M+
↑
P2+ I1
↓
↑
I2
↓
SMART X96
↑
I3
↓
ESCT-SC
SECT-RJ SECT-SC
32
meters
96mm
m
96m
70 mm
L1
L2
L3 Daisy connection for power supply. Height 96mm
N Max. 32pcs meters can be connected. 91~92mm Width 96mm
The example shows a wiring in 3p4w network. Plug-in type voltage terminals. 1~2mm Depth 70mm
the meter can also work in 3p3w and 1p2w system.
Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Smart X96 F~J Series Max. short duration input voltage
Nominal input voltage burden
2 x nominal voltage for 1 second
< 0.2VA per phase
Relative humidity
Shock
0 to 95%, non-condensing
30g in 3 planes
SMART ENERGY ANALYZER FOR SINGLE AND THREE PHASE SYSTEMS Nominal input current 100mA / 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
Max. continuous input overload current 120% of nominal Altitude 3000m
● Multi-parameter Measurements
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
●U p to 63 rd THD and IHD
●R S485 Modbus RTU
●E thernet TCP Gateway Power supply Outputs
Operating range Self powered (from any of the three phases)
●M ulti-tariffs Pulsed output relay (configurable) Opto-coupled, potential-free SPST-NO contact
Supply burden < 2W / 10 VA
●D igital Input/Output Contact Rating current 2-27mA at 27V DC
●A ccuracy Class 0.5s Contact Rating voltage 5-27V DC
Accuracy
●B ar Graph for Power Indication MID Voltage (V) 0.5% of range maximum
Pulse Width 60 / 100 / 200 ms
Pulse rate of S0 1 0.01 / 0.1 / 1 / 10 / 100 kWh/kVArh
●B acklit LCD Display for Full Viewing Angles
Current (A) 0.5% of range maximum Pulsed output of S0 2 (non-configurable) 3200IMP/kWh
●P ush-in Installation and Plug-in Connection Frequency (Hz) 0.2% of mid-frequency Communications Modbus RTU (RS485)
Power factor (PF) 1% of unity (0.01) Type 2-wire half duplex
Active power (W) 1.0% of range maximum Baud rate 2400,4800, 9600, 19200, 38400
Reactive power (VAr) 1.0% of range maximum Address 1 to 247
Apparent power (VA) 1.0% of range maximum
Active energy (kWh) Class 0.5S IEC62053-22
Introduction Class 1.0 IEC62053-21 Enclosure
Enclosure Style DIN 96 panel mount
Reactive energy (kVArh) 1.0% of range maximum to IEC 62053-24
The multifunction energy analyzer SMART X96 F~J series is a top new-generation intelligent panel meter with built-in interfaces provides RS485 Dimensions 96x96x62 mm
THD 2% to 63rd harmonic
Modbus RTU and Ethernet TCP/IP communication. Digital input and outputs are provided for external signal counting and external device control. Panel cut-out 92x92mm
30 type's parameters can be set for alarm. This series is widely used not only in the electricity transmission and power distribution system, but also Panel thickness 1-2 mm
in the power consumption measurement and analysis in LV/MV Intelligent power grid. The Unit can be used as a gateway for Modbus RTU/TCP. Measured Range
Protection rating Ip51 (Indoor)
Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
Material UL 94-VO
SMART X96 measures and displays the characteristics of 1p2w, 3p4w and 3p3w supplies, including voltage, frequency, current, power and active Current (A) 5 – 120% of nominal
Weight 340 g
and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand etc. Energy is measured in terms of kWh, kVArh and kVAh. Frequency (Hz) 45– 66 Hz
Cable size 0.05mm-4mm stranded wire
Maximum demand current can be measured over preset periods of up to 60minutes. The SMART X96 can be configured to work with a wide range Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
Terminals Voltage: Shrouded screw-clamp. Current: RJ12
of CTs and Pts, giving the unit a wide range of operation. Energy 8digit, upto 9999999.9 kWh
Power factor 4 quadrant
THD 0 – 40% upto 63rd harmonic
INSTALL Dimensions
Smart X96 —5—J—2—4—C
1: 100mA
2: 100mV
3: 333mV SMA RT X96
92mm
2: Aux. AC power supply
3: Aux. DC power supply
1: Single tariff
2: 2 Tariffs
4: 4 Tariffs 96m
m mm
70
B:Class 1 92mm
C: Class 0.5s
D: Class 0.2s
Height 96mm
Width 96mm
1~2mm Depth 70mm
Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing
Wiring diagram
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
CT CT CT
L1 * *
* L1 * *
Smart X835 —B—1—1—B L2 *
L1 *
* L2 N
L3 * *
P: 2 Pulse outputs * L3 *
N 1-phase 2-wire
3-phase 3-wire
B:RS485 Modbus, 2 Pulse ouptuts 3-phase 4-wire
DIO: 2 Digital Inputs , 2 Digital Outputs, RS485 Modbus Dimensions
AO: 2 Analog Outputs , RS485, 2 Pulse outputs
2 1 2 1
L N G + - + - + - + - A+ B-
1: Single Tariff 11 12 13 17 18 19 20 17 18 19 20 21 22
4: Multi Tariffs aux. power supply SMART X835-P SMART X835-B
m
Height 96mm
m
72
Width 96mm
Depth 72mm
Input Environment
Nominal input voltage 100-276V AC ( L-N ) 173-480V AC( L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing
Wiring diagram
1 2 3 4 5 6 13 14 15 16 17 18 1 2 3 4 5 6 13 14 15 16 17 18
*
MV: 333mV CT input, Multi Parameters, Rs485 Modbus L3 *
*
L3 *
*
V: 3 phase voltage (L-N,L-L), Rs485 Modbus N
3-phase 3-wire
A: 3 phase Current , Rs485 Modbus 3-phase 4-wire
1 2 3 4 5 6 13 14 15 16 17 18
B:Class 1
C: Class 0.5s + - + G B- A+
CT 19 20 21 22 23 24
*
L1 *
N Height 96mm
1-phase 2-wire Width 96mm
Depth 50mm
Input Environment
Nominal input voltage 57.7 – 276V AC L-N (100-480V L-L) Operating temperature -25˚C to +55˚C
Max. continuous input overload voltage 120% of nominal Storage temperature -40˚C to +70˚C
Max. short duration input voltage 2 x nominal voltage for 1 second Relative humidity 0 to 95%, non-condensing
Nominal input voltage burden < 0.2VA per phase Shock 30g in 3 planes
SMART X72 Nominal input current 5A Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g
Nom. Input current burden < 0.1 VA Dielectric Voltage 4kV between voltage and current to earth
SMART POWER ANALYZER Max. continuous input overload current 120% of nominal Altitude 3000m
Max. short duration input current 20 x nominal current for 1 second Warm-up 1 minute
Mult-parameters measured
RS485 Modbus RTU & two pulse output
Power supply Outputs
Digital input & Digital output Auxiliary 85-276V AC 50/60Hz or 120-380V DC Communications Modbus RTU (RS485)
CT&PT programmable Supply burden < 2W /10 VA Type 2-wire half duplex
THD of Voltage and current Baud rate 2400,4800, 9600, 19200, 38400
Address 1 to 247
Accuracy
Voltage (V) 0.5% of range maximum
Current (A) 0.5% of range maximum Enclosure
Frequency (Hz) 0.2% of mid-frequency DIN 96 panel mount
Enclosure Style
Power factor (PF) 1% of unity (0.01) 96x96x50 mm
Dimensions
Active power (W) 1.0% of range maximum 92x92mm
Panel cut-out
Reactive power (VAr) 1.0% of range maximum Front IP54, Rear IP30
Protection rating
Apparent power (VA) 1.0% of range maximum UL 94-VO
Material
Active energy (kWh) 1.0% of range maximum to IEC 62053-21 300 g
Weight
Introduction Reactive energy (kVArh)
THD of current and voltage
1.0% of range maximum to IEC 62053-24
2%
Cable size 0.05mm-4mm stranded wire
Voltage: Shrouded screw-clamp. Current: RJ12
Terminals
The multifunction energy analyzer SMART X72 series is an intelligent panel meter, used not only in the electricity transmission and power
distribution system, but also in the power consumption measurement and analysis in high voltage intelligent power grid.
Measured Range
The unit measures and displays the characteristics of single phase two wires, three phase three wires and three phase four wires supplies, including Voltage (V) 5 – 120% of nominal (Min 100V -self powered)
voltage, frequency, current, power , active and reactive energy, imported or exported, Harmonic, Power factor, Max. Demand, etc. Energy is Current (A) 5 – 120% of nominal
measured in terms of kWh, kVArh. Maximum demand current can be measured over preset periods of up to 60minutes. In order to measure energy, Frequency (Hz) 45 – 66 Hz
the unit requires voltage and current inputs in addition to the supply required to power the product. The requisite current input(s) are obtained via
Power (W, VAr, VA) 5 – 144% of nominal (bi-directional)
current transformers The SMART X72 can be configured to work with a wide range of CTs, giving the unit a wide range of operation. Built-in
Energy 8 digit, upto 9999999.9 kWh
interfaces provide pulse and RS485 Modbus RTU outputs. Configuration is password protected.
Power factor 4 quadrant
THD 0 – 40% upto 21st harmonic
Wiring diagram
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Smart X72 —CT—B
B:Class 1 L N G
C: Class 0.5s 1 2 3 4 5 6 7 8 9 10
11 12 13
aux. power supply Height 72mm
CT Width 72mm
Do11 Do12 Do11 Do12 COM A+ B-
L1
*
*
Depth 74mm
14 15 16 17 18 19 20
N
1-phase 2-wire
Specification Specification
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Power consunption
Pm1000 Series 2 times/ second ( instantaneous) Storage temperature
Reference temperature
-40°C~+70°C
23°C~±2°C
voltage: < 1VA / phase
Single Phase System Impedance Electromagnetic environment E2
current: < 0.4VA / phase
Degree of pollution 2
Frequency current : < 20m
High precision measurement of V, A,Hz, W, PF Protection against penetration of dust and water IP51
Auxiliary Power Supplly 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Class 0.5 Working Range AC 220V Electrical fast transient burst lever Class 4
Rated voltage: AC0-600V/DC, 0-1000V Power Consumption : < 4VA
Wiring diagram
Introduction
The Eastron PM1000 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor in the grid. It is convenient to install, easy to wire, and simple to maintain, and it is an upgrade product of
various tyes of the pointer header.
72mm
96mm
72m
m mm
45 96mm SIZE 1: 96X96X84mm
SIZE 2: 72X72X45mm
Pm1000 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
W: Power
Cos: PF
48mm
1: 48x96
2: 72x72
96m
3: 96x96 m
mm
E: LED
79
C: LCD
SIZE 3: 96X48X79mm
AC:AC220V
DC: AC/DC85~265V
Specification Performance
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
Pm1500 Series Power consunption 1.2 times ( Continued), Operating temperature -25°C~+55°C
-40°C~+70°C
2 times/ second ( instantaneous) Storage temperature
Single Phase System 23°C~±2°C
Reference temperature
voltage: < 1VA / phase
Impedance Electromagnetic environment E2
current: < 0.4VA / phase
High precision measurement of V, A,Hz, W, PF etc Degree of pollution 2
Frequency current : < 20m
Class 0.5 Protection against penetration of dust and water IP51
Auxiliary Power Supplly 45~65 Hz or DC Class 4
ESD ( Electro- Static discharge) level
Support for RS485 Modbus RTU communication Working Range AC 220V Class 4
Electrical fast transient burst lever
Support for digital input, output, analog output Power Consumption : < 4VA Electricalsurge Class 4
Communication Modbus RTU Height above sea level ≤2000m
Rated voltage: AC0-600V/DC, 0-1000V
2 wire half duplex Insulation resistance >100Mohm
Type
Rated current: 1A / 5A AC, 0~10A DC 1minute
Baud Rate 1200,2400( default),4800,9600 Warm up
Frequenct: 45~65 Hz or DC
Digital Output 4
Auxiliray power supply: AC/ DC 85V~265V
Analog Output 0/4~20mA or 0-5/10V
Dimension optional: 48*96, 72*72, 96*96
Wiring diagram
Introduction
The Eastron PM1500 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor, kWh etc in the grid. DI / DO and AO is optional. It is convenient to install, easy to wire, and simple to
maintain. Built-in interfaces provides RS485 Modbus RTU communication. Digital input and outputs and Analog output are provided for external
signal counting and external device control.
Pm1500 —A—1—E—A/D
A: Current
B: Voltage
Hz: Frequency
Cos: PF
W: Power
C: V/A/Hz
M: Multi parameters 1: 48x96
2: 72x72
3: 96x96
E: LED
C: LCD
AC:AC220V
DC: AC/DC85~265V
Specification Specification
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Overload voltage
Storage temperature -40°C~+70°C
Pm3000 Series Power consunption
2 times/ second ( instantaneous)
voltage: < 1VA / phase
Reference temperature 23°C~±2°C
Electromagnetic environment E2
Three Phase System current: < 0.4VA / phase
Degree of pollution 2
Impedance current : < 20m
Protection against penetration of dust and water IP51
High precision measurement of V, A,Hz, W, Var,PF Frequency 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Auxiliary Power Supplly Working Range AC 220V
Class 0.5 Electrical fast transient burst lever Class 4
Power Consumption : < 4VA
Rated voltage: AC0-600V/DC, 0-1000V
Rated current: 1A / 5A AC, 0~10A DC
Frequenct: 45~65 Hz or DC
Auxiliray power supply: AC/ DC 85V~265V
Dimension optional: 48*96, 72*72, 96*96 Wiring diagram
Introduction
The Eastron PM3000 series digital three phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor in the grid. It is convenient to install, easy to wire, and simple to maintain, and it is an upgrade product of
various tyes of the pointer header.
Pm3000 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
W: Power
Var: Reactive Power
Cos: PF
1: 80x80
2: 72x72
3: 96x96
E: LED
C: LCD
AC:AC220V
DC: AC/DC85~265V
Specification Performance
Rated voltage AC 0-600V, DC 0-1000V Operating humidity ≤ 90 %
Rated current AC1A / 5A, DC 0-10A Storage humidity ≤ 95 %
1.2 times ( Continued), Operating temperature -25°C~+55°C
Overload voltage
2 times/ second ( instantaneous) Storage temperature -40°C~+70°C
Pm3500 Series Power consunption
voltage: < 1VA / phase Reference temperature 23°C~±2°C
Electromagnetic environment E2
Three Phase System current: < 0.4VA / phase
Degree of pollution 2
Impedance current : < 20m
Protection against penetration of dust and water IP51
High precision measurement of V, A,Hz, W, Var,PF Frequency 45~65 Hz or DC
ESD ( Electro- Static discharge) level Class 4
Auxiliary Power Supplly Working Range AC 220V
Class 0.5 Electrical fast transient burst lever Class 4
Power Consumption : < 4VA
Electricalsurge Class 4
Rated voltage: AC0-600V/DC, 0-1000V
Communication Modbus RTU Height above sea level ≤2000m
Rated current: 1A / 5A AC, 0~10A DC Type 2 wire half duplex Insulation resistance >dayu100Mohm
Wiring diagram
Introduction
The Eastron PM3500 series digital single phase panel meters adopt alternating current sampling techniques, which enables it to measure voltage,
current, Frequency, Power, Power Factor, kWh etc in the grid. DI / DO and AO is optional. It is convenient to install, easy to wire, and simple to
maintain. Built-in interfaces provides RS485 Modbus RTU communication. Digital input and outputs and Analog output are provided for external
signal counting and external device control.
Pm3500 —A—1—E—A/D
A: Current
V: Voltage
Hz: Frequency
Cos: PF
W: Power
C: V/A/Hz
M: Multi parameters
1: 80x80
2: 72x72
E: LED
3: 96x96
C: LCD
AC:AC220V
DC: AC/DC85~265V
Interface RS232/485/422 x 1
Modbus RTU to Modbus TCP Ethernet
10/100 Mbps, Rj45,
2 KV surge protection
RS485/422 Lsolation 2.5KV Baud Rate 1200bps~115200bps
Introduction
ESP-2000 series is a high performance serial device server and Modbus Gateway product designed by Eastron for lightning resistance ,
anti-eletromagnetic interference and resisting bad environment requirements, is the flagship product on serial device e server.
The Gateway are designed for easy integration of Modbus TCP and RTU networks. With those models, Modbus serial slave devices can
be seamlessly incorporated into an existing Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.
The ESP-2100, ESP-2200,ESP-2400,ESP2800 offer features that make network integration easy, customizable, and compatible with
any Modbus network.
ESP-2200 ESP-2400 ESP-2800
Parameter: Parameter: Parameter:
Rs232 Interface Rj45interface. qty. 2 Rs232 Interface Db9.qty. 4 Rs232 Interface Db9.qty. 8
Rs485 Interface Terminal, qty. 2 Rs485 Interface Terminal, qty. 4 Rs485 Interface Equip Db9to terminal pinboard, qty. 8
Rs422 Interface Need customized to open, qty. 2 Rs422 Interface 4 Line terminal, qty. 4 Rs422 Interface None
Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 4W Input Voltage DC9~24V, power consumption less than 5.4W
ESP-2 —100—1
197.7 270
200: 2x RS232/422/485 ports 197.7 246
Port1 Port2 Ethernet Ethernet
0 4(0.16)
RS232/422 RS232/422 Uplink 10/100M
0 6(0.24)
17.9
26 5
07 13.0 7
80(3.15)
6x8=48
95
43
(0.98)
95
88
88
(0.28)
25
11.5
(0.98)
25
Gateway ESP-2200
ESP-4000 SERIES
RS232/422/485 to WIFI ESP-5000 SERIES
RS232/485 to GPRS/3G/4G
Convert Between RS232/422/485 to WIFI
Ethernet Port available Support RS232/485 to GPRS ESP-5100
Each RS485 port supports up to 256 nodes Support RS232/485 to 3G/4G ESP-5307
Support Modbus TCP to RTU. Support RS232/485 to Ethernet
Support IEEE802.11g/b/n
Easy Hardware setup
Introduction Introduction
ESP-4142 and ESP-4144 is Wifi serial device server designed by Eastron, supporting RS232/422/485 to Wifi. It supports Ethernet and
ESP-5 series covers 2G/3G/4G mobile network. It converts serial port RS232/RS485 to GPRS (ESP-5100) ,and to 3G/4G(ESP-5307). ESP-5100 is
Wifi simultaneous access. the host serial software can self-adapt serial parameter, without setting device serial baudrate.
good option for applications which does not ask high speed communication. ESP-5307 is advanced version with fater transmission speed.
The ESP-4000 series is a high performance serial device server and Wifi Gateway product designed by for lightning resistance ,
ESP-5307 supports TD-LTE/FDD-LTE/WCDMA/TD-SCDMA/GSM. An extra Ethernet port is provided, which can be used at same time when
anti-eletromagnetic interference and resisting bad environment requirements. it provides an easy and wireless integration way of
2G/3G/4G is working. P2P connection is also possible.
Modbus TCP and RTU networks. With those models, Modbus serial slave devices can be seamlessly incorporated into an existing
Modbus TCP network, and Modbus TCP salves can be made accessible to serial masters.
Parameter: Parameter:
Serial Port Type RS232/RS485 Transmission Rate 1)3G net speed:uplink 5.76Mbps downlink 7.2Mbps.
2)4G net speed:uplink 2Mbps downlink 68Mbps.
Baud Rate 1200~115200bps
Frequency range 900MHZ/1800MHZ,GPRS multi-slot class 10/8,GPRS SIM Card Voltage: 3V,1.8V; Size: Big Card
mobile station class B
Antenna Interface Optional 50Ω/SMA glue stick antenna or sucker antenna
WIFI IEEE802.11b/g
Transmission Rate Serial Port Type RS232/RS485
Downlink Max:85.6kbps;Uplink Max:42.8kbps;
Antenna Stick antenna, sucker antenna
Support PBCCH,Coding schemes CS 1,2,3,4,CSD Serial Parameter Baud Rate:1200~115200bps
up to14.4kbps, USSD, PPP-stack
Interface RS232/485/422 serial port
Power Port Q2.1 outlet, can be customized to power terminal input
Baud Rate 1200bps~115200ps SIM Card Voltage 3V,1.8V Input Voltage 9~24V DC
Interface Type 2 line Terminal or 5.5mm, inside positive outside negative, Size L×W×H=9.4cm×6.5cm×2.5cm
Power Interface In-positive, out-negative, standard outlet; 2 line terminal
standard power plug (alternative)
Work Temp. Humidity -40~85℃,5~95% RH
Input Voltage 9~48V input, less than 1W
Input Voltage 9~24V DC
Size L x W x H=9.4cmx6.5cmx2.5cm
Current No card or standby in 77mA
ESP-7000 SERIES
ESP-6000 SERIES RS 485 to LOR/Wifi/Ethernet
LORA to Ethernet
Support Rs485 to Lora ESP-7100
Support Lora to Ethernet Support Rs485 to Wifi ESP-7110
Support Lora to RS485 Support Rs485 to Ethernet ESP-7120
Introduction Introduction
ESP-6 is a high-performance LoRa gateway that implements RS485 and LoRa, TCP / IP and LoRa-related translation functions. ESP-7 Series is a high-performance converter, to achieve RS485 and LoRa / WIFI / Ethernet conversion function. RS485 port can be connected
As a gateway in LoRa network, ESP-6 adopts LoRa ad hoc network communication mode, and LoRa meter or LoRa converter to the conventional RS485 communication meter, through the built-in processor, to achieve the conversion of the two communications.
can form a perfect LoRa remote meter reading system. LoRa network using MESH wireless Ad Hoc network, while supporting star, ESP-7100 converts RS485 to LoRa; ESP-7110 converts RS485 to Wifi; ESP7120 converts RS485 to Ethernet. With ESP series Gateway, , they can
cluster network, the depth of the leading network routing, automatically select the best route, up to 4 relay hopping; with be used to coperate with LoRa Gateway (ESP-6 series) to form a complete wire / wireless meter reading system.
routing auto-repair feature to achieve seamless new Add or delete devices without manual intervention in routing operations.
Input channel:
Output channel : Input channel: ESP-7100 Output :
Communication mode LoRaMESH or LoRaWan
Output port 1 Ethernet Input port Rs485 Modbus RTU Communication mode LoRaMESH or LoRaWan
Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Interface parameters RJ45,10/100Mbps Baud rate 1200 ~ 38400 bps Communication frequency 433Mhz, 470Mhz, 868Mhz, 915Mhz
Communication speed 2.93~0.5 kbpsA (Configurable)
Operating mode TCP server Parity bit None/Odd/Even Communication speed 2.93~0.5 kbps (Configurable)
Maximum transmit power 20dBm
Output port 2 RS485 Modbus RTU Stop bit 1/2 bit Maximum transmit power 20dBm
Receiver sensitivity -112dBm/9.6kbps @GFSK
Baud rate 1200 ~ 38400 bps Data bits 8 bit Receiver sensitivity -112dBm/9.6kbps @GFSK
Maximum communication 1.5km (urban road);2.5km (Open area)
Parity None/Odd/Even Max. Bus Load 32pcs Submeters
Maximum communication 1.5km (urban road);2.5km (Open area)
distance Point to point
Stop bit 1/2 bit distance Point to point
Networking mode MESHwireless ad hoc network,up to 4 relay hopping Temperature and humidity parameter:
Data bits 8 bit Networking mode MESHwireless ad hoc network,up to 4 relay hopping
Operating temperature -25 to 55°C
ESP-7110 Output :
Temperature and humidity parameter: Storage temperature -40℃to +70℃
Power supply parameters: WIFI IEEE802.11b/g
Operating temperature -25 to 55°C Humidity range 0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<2.5W Antenna Stick antenna, sucker antenna
Storage temperature -40°Cto +70°C
Maximum input voltage 28VDC Power supply parameters:
Humidity range
ESP-7120 Output :
0 to 95%, No condensation
Supply voltage 9~24VDC, maximum power consumption<1.5W
Ethernet 10/100 Mbps, Rj45,2 KV surge protection
Maximum input voltage 28VDC
TCP Server, TCP Client,UDP/UDP Multicast,
Work Mode
TCP Server/Client Coexist
81
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Overload withstand 1.2 x rated current continuously
26
Phase angle Less than 2 degrees at 50% of rated current Rated dynamic current 2.55 x Ith
Insulation voltage 600 Vac
16
Secondary terminals M4 screw terminals
58.0
Maximum primary voltage 5000 Vac ( Insulated Conductor) Enclosure Flame retardant grad classified UL 94V-0 77.0
Dielectric strength 2.5 KV / I mA / I min Aperture holes centers 25,35,45mm
107.5
Operating temperature -15°C to 60°C Plug-in metal feet for wall or base Mounting ESCT-SC325
Mounting hardware
Operating humidity <85% Bus-bar and DIN-rail
Case material PC / UL 94-VO Compliant with IEC/EN60044-1
Bobbin PBT
Internal structure Epoxy
Compliant with IEC/EN60044/1 Model Ratio (A) Burden ( VA)
14
class:0.5 Class:1.0
5
13 ESCT-SC325 60/1 - 1
ESCT-RJ335 - 86.0
ESCT-SC325 100/1 1.5
Model Rated Amp Output Burden ( VA)
class:0.5 Class:1.0 ESCT-SC325 125/1 1.5 1.5
ESCT-RJ335 60A 100mA 0.25 0.25 ESCT-SC325 150/1 1.5 1.5 ESCT-SC335
ESCT-RJ335 125A 100mA 0.25 0.5 ESCT-SC325 300/1 1.5 1.5
ESCT-RJ335 150A 100mA 0.25 0.5
91
ESCT-RJ335 200A 100mA 0.25 0.5 ESCT-SC335 100/1 - 1.5
31.5
ESCT-RJ335 250A 100mA 0.25 0.5 ESCT-SC335 125/1 - 1.5
-
91.0
31.0
31
ESCT-RJ345 300A 100mA 0.25 0.5 ESCT-SC335 200/1 1.5 1.5 31.0
ESCT-RJ345 400A 100mA 0.25 0.5 142 ESCT-SC335 250/1 1.5 1.5 123.0
ESCT-RJ345 500A 100mA 0.25 0.5 142.0
ESCT-RJ345 600A 100mA 0.25 0.5 ESCT-C345 250/1 1.5 1.5 ESCT-SC345
ESCT-RJ345 630A 100mA 0.25 0.5 ESCT-C345 300/1 2.5 2.5
ESCT-C345 400/1 2.5 2.5
ESCT-C345 500/1 2.5 2.5
14
5
600/1 2.5 2.5
ESCT-RJ345 ESCT-C345
13
ESCT-C345 630/1 2.5 2.5
Split Core
Cost effective three-phase moulded case
Primary input 100A~5000A
Ratio’s ranging from 60/5 to 630/5
Secondary output 5A / 1A
ESCT-C Series Integrated wire sealable terminal cover ESCT-B Series Two building fixing methods: Base; Busbar mounting
3-IN-1 CURRENT TRANSFORMER Busbar, DIN-rail and metal feet mounting hardware supplied SPLIT CORE CURRENT TRANSFORMER Wide inner window, allowing clamping of big cables or bus-bars
Combined M4 posi /slot screw
Standard: IEC60044-1, EN60044-1, VDE0414-44-1, GB1208-2006
Dimension
Specification Specification
Dimension
Rated current 60A to 630A loads Frequency 50Hz-60Hz
Rated output 5A ( AC ) Rated current 100A to 5000A loads
Accuracy Class 0.5 or 1 from 20% to 120% of rated current Rated output 5A / 1A ( AC )
Phase angle Less than 2 degrees at 50% of rated current Accuracy Class 0.5 or 1 from 20% to 120% of rated current
105
20
30
Insulation voltage 600 Vac S1 S2 S1 S2 S1 S2
Phase angle less than 2 degrees at 50% of rated current
Maximum primary voltage 5000 Vac ( Insulated Conductor) Insulation voltage 600Vac
60
80
Dielectric strength 2.5 KV / I mA / I min Maximum primary voltage 5000Vac ( Insulated Conductor)
14
25
Operating temperature -15°C to 60°C Dielectric strength 2.5 KV / I mA / I min
24
Operating humidity <85% Operating temperature -15°C to 60°C ESCT-B23
Case material PC / UL 94-VO 77 Operating humidity <85%
Bobbin PBT 77 Case material PC / UL 94-VO
Internal structure Epoxy Bobbin PBT
ESCT-C325 Internal structure Epoxy 50
80
145
70
52
32
Model Ratio (A) Burden ( VA) Model Burden ( VA)
class:0.5 Class:1.0 Ratio (A) class:0.5 Class:1.0
ESCT-C325 60/5 - 1 S1 S2 S1 S2 S1 S2 ESCT-B23 100/5 1.5 2.5 114
ESCT-C325 100/5 1.5 1.5 ESCT-B23 150/5 1.5 2.5 ESCT-B58
80
38
25
ESCT-C325 150/5 1.5 1.5 35 ESCT-B23 250/5 2.5 5
ESCT-C325 200/5 1.5 ESCT-B23 300/5 5 5
- 105 ESCT-B23 400/5 5 5
105
100/5 - 1.5 250/5 1.5 2.5 80
145
ESCT-C335 ESCT-B58
70
52
32
ESCT-C335 125/5 - 2.5 ESCT-C335 ESCT-B58 300/5 2.5 5
ESCT-C335 150/5 1.5 3.75 ESCT-B58 400/5 3.75 5
ESCT-C335 160/5 1.5 1.5 ESCT-B58 500/5 5 7.5 144
ESCT-C335 200/5 1.5 1.5 ESCT-B58 600/5 5 7.5
ESCT-C335 250/5 1.5 ESCT-B58 750/5 5 10 ESCT-B88
S1 S2 S1 S2 S1 S2
185
30
120
80
ESCT-C345 400/5 2.5 2.5 ESCT-B812 600/5 2.5 5
70
52
32
45 141
ESCT-C345 500/5 2.5 2.5 ESCT-B812 750/5 5 10
ESCT-C345 600/5 2.5 2.5 ESCT-B812 800/5 5 10
141
ESCT-C345 630/5 2.5 ESCT-C345 ESCT-B812 1000/5 7.5 10 144
ESCT-B812 1200/5 7.5 10
ESCT-B812
ESCT-B812 1250/5 7.5 10
ESCT-B812 1500/5 7.5 10
ESCT-B816 1000/5 10 15
ESCT-B816 1500/5 10 15
245
80
160
ESCT-B816 2000/5 15 20
87
71
50
ESCT-B816 2500/5 20 25
ESCT-B816 3000/5 20 30
ESCT-B816 4000/5 20 30 184
ESCT-B816 5000/5 20 30 ESCT-B816
ESCT-B816 6000/5 20 30
75 Product Catalog EASTRON Product Catalog EASTRON 76
CURRENT
SMART TRANSFORMER
DIN-RAIL METER
65.0
Insulation voltage 600Vac Insulation voltage 600Vac ESCT-TU10 5 0.1 0.5 or 1
Maximum primary voltage 5000Vac (Insulated Conductor) Maximum primary voltage 5000Vac (Insulated Conductor) ESCT-TU10 10 0.1 0.5 or 1
Dielectric strength 2.5KV/1mA/1min Dielectric strength 2.5KV/1mA/1min ESCT-TU10 20 0.1 0.5 or 1
45.0 40.0
Operating temperature -15 °C to 60 °C . Operating temperature -15 °C to 60 °C . ESCT-TU10 50 0.1 0.5 or 1
Operating humidity <85% Operating humidity <85% ESCT-TU10 75 0.1 0.5 or 1
ESCT-T24-1 Case material PC / UL94-V0
Case material PC / UL94-V0
Bobbin PBT Bobbin PBT ESCT-TU16 5 0.333 0.5 or 1
Core Permalloy 81.5
35.7 Core Permalloy ESCT-TU16 10 0.333 0.5 or 1
Internal structure Epoxy Internal structure Epoxy ESCT-TU16 50 0.333 0.5 or 1
Leads UL 1015,Twisted Pair, 22AWG ESCT-TU16 100 0.333 0.5 or 1
ESCT-TU16 150 0.333 0.5 or 1
Model Ratio (A) Burden ( VA) Dimension ESCT-TU16 5 0.1 0.5 or 1
class:0.5 57.0 51.0
Class:1.0
100/1 ESCT-TU16 10 0.1 0.5 or 1
ESCT-T24-1 - 1.5
ESCT-T24-1 150/1 - 1.5 ESCT-T36-1 ESCT-TU16 50 0.1 0.5 or 1
41.0
ESCT-T24-1 250/1 1.5 2.5
ESCT-T24-1 300/1 1.5 2.5 24.5
65.0
150/1 - 1.5
ESCT-TU10 ESCT-TU24 100 0.333 0.5 or 1
ESCT-T36-1
200/1 ESCT-TU24 250 0.333 0.5 or 1
ESCT-T36-1 1.5 2.5 45.0 40.0
45.5
400/1 ESCT-TU24 10 0.1 0.5 or 1
ESCT-T36-1 1.5 2.5
ESCT-T24-5 ESCT-TU24 50 0.1 0.5 or 1
ESCT-T36-1 500/1 2.5 3.75
600/1 ESCT-TU24 100 0.1 0.5 or 1
ESCT-T36-1 2.5 5
29.0 31.5 ESCT-TU24 250 0.1 0.5 or 1
35.7
ESCT-TU16 ESCT-TU24 300 0.1 0.5 or 1
81.5
65.0
250/5 ESCT-TU36 100 0.333 0.5 or 1
ESCT-T24-5 1.5 2.5
57.0 51.0
300/5 ESCT-TU36 250 0.333 0.5 or 1
ESCT-T24-5 1.5 2.5
ESCT-TU36 400 0.333 0.5 or 1
ESCT-T36-5
100/5 45.0 40.0 ESCT-TU36 600 0.333 0.5 or 1
ESCT-T36-5 - 1.5
ESCT-T36-5 150/5 - 1.5 ESCT-TU24 ESCT-TU36 20 0.1 0.5 or 1
Dimension
Specification
Specification
Frequency 50-60Hz Wiring diagram
Current Range 10A to 100kA
Rated current 5A to 3000A loads
Rated output 333mV (AC) Rated output 0.333Vac at rated current with Integrator,
Accuracy ±1% from 20% to 120% of rated current 100mV/per 1000A @ 50Hz without integrator
Phase angle less than 2 degrees at 50% of rated current Accuracy ±1% from 5% to 120% of rated current with
Insulation voltage 600Vac integrator(45-65Hz) ESCT-RC-060-100A/0.333V output-
100Aac to 0.333Vac@50/60Hz output+
Maximum primary voltage 5000Vac (Insulated Conductor) Phase Angle ≤±1°5% to 120% from 5% to 120% of rated current Power supply 9vdc power-
Power+
Dielectric strength 2.5KV/1mA/1min Linear 0.5%
Operating temperature -15 °C to 60 °C . Frequency 1Hz-1MHz ,50/60 Hz nominal CT 1 CT 2 CT 3
CURRENT INPUTS
+9VDC
GND
220VAC
Case material PC / UL94-V0 Power supply 7-30VDC (9 Vdc,12 Vdc recommended ) Powersupply
Electricity Meter
Specification Introduction
Specification Introduction
Rated Frequency 50Hz-60Hz
ESCT-ABO perfect designed plastic case current transformer, advanced Rated Frequency 50Hz-60Hz
Rated current 5A to 5000A loads
snap on body, high accuracy ( up to Class 0.2S), humanization transparent ESCT-DM is world famous MINI design plastic case current transformer,
Rated output 5A, 1A, 0.5A, 0.25A, 0.1A Rated current 15A to 300A loads
cover and lead seal hole design makes the CT very easy to identify after snap on body, be wildly used in generators. It is available for connecting
Accuracy ±1% from 20% to 120% of rated current Rated test voltage 3kV AC ( 1min)
long term use and perfect anti-stealing electricity. Rated short-time thermal current (Ith) 60In with cable, and also available for connecting with Busbas. Its primary
Rated short-time thermal current (Ith) 60In
Rated voltage (Um) 0.72Kv AC. currents between 15A~300A with 5A or 1A secondaries with up to
Rated voltage (Um) 1.2 In
-10°C~50°C Dimension Rated output 5A or 1A Class1.0 accuracy Performance.
Operating temperature
Housing self-extinguishing class VO Rated voltage (Um) 1.2 In
Description Description
Specification Panel Symbol legend
Output relay ON Specification Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday
Output relay OFF
Supply terminals A1,A2 Supply terminals A1-A2 C1 Channel 1
Output relay 1
Pulse terminal S Rated voltage AC220-240V Relay status: Activate
Output relay 2
Rated frequency 50/60Hz Deactivate
Supply voltage AC/DC 24-240V ONStart SET Parameters setting
Automatic mode
min
ONStart Starting with ON
Power consumption 1W
Rated frequency 50/60Hz t
Manual mode
OFFStart Starting with OFF
Supply volltage tolerance ±10%
Time range 0~9999s, 0~9999min 1 Holiday mode
Time impulse release by rising edge Number of channels
Repetition accuracy max.±3s/24h 25 ºC Time impulse release by falling edge Program astronomical
Sunrise
-5ºC~+40ºC
Wiring diagrams Pollution degree 3
Ambient temperature Wiring diagrams
-10ºC~+50ºC L Altitude ≤2000m
Storage temperature
0.5mm~1mm
2 2 N Ambient temperature -30°C~55°C
Wire size
Permissable relative humidity ≤50%(40°C,without condensation)
Torque 0.5Nm A1
Storage temperature -35°C~70°C
Mounting TH-35 DIN-Rail Wire size 2 2
A1 15
1mm ~ 4mm
A1 15 25
25 28 A1 A2
Tightening torque 0.5Nm
24-240V
50/60Hz Mounting TH-35 Rail(EN60715)
Front-face panel Dimensions 90*36*64mm Menu Ok
Standard IEC60947-1/IEC60947-2-7
S A2 18 16 28 C1
A2 18 16 18 15 16 A2
Front-face panel
Relay 2 Output contact Supply terminals MENU OK
:DD-MM-YY, 23th.September.2013
18 15 16 S N
Supply terminal L L
25 28 A1 A2 24-240V
Dimensions
50/60Hz
Dimensions
LCD display
OFFStart
A1
220-240V
t1 50/60Hz L
25 28 A1 A2
24-240V
50/60Hz
1 LCD display
35
45
C1
Keys
90
MENU OK
35
45
90
Menu ok
Control keys
MENU OK Menu Ok
C1
18 15 16 S 18 15 16 N
18 15 16 S C1 26
18 15 16 A2 44
Relay 1 Output contact Pulse terminals
26 60
36
44 65
Output - channel 1 Supply terminal N
60 36
65
ESRD-TPW1/2 Double channels ESRD-ST1 LED indication for power supply and relay status
DOUBLE CHANNEL DIGITAL WEEKLY Automatic transfer of weekdays DIN Rail mounting
24-264V AC/DC input supply
TWILIGHT SWITCH
Double-module, mounted on TH-35 rail
Function diagram
Specification Description
Specification
Supply terminals A1-A2 Panel 1 2 3 4 5 6 7 Days of the week Monday, Tuesday, ...Sunday
Rated control voltage AC220V
Ambient light intensity
Rated insulation voltage 250V ○C1 manual operation ○C2 manual operation
C1 C2
Protection degree IP20 Ambient temperature -25ºC~+40ºC LIGHT DEPENDENT RELAY
Un:AC220V 50/60Hz
U
L 25A AC1
Pollution degree 3
Altitude ≤2000m Wiring diagrams
B1
Ambient temperature -20°C~55°C Front-face panel B2
Lux
Permissable relative humidity ≤50%(40°C,without condensation) ESRD-ST1
28 25 26 A1
Storage temperature -30°C~70°C A1
C2 N C B1 B2
Output contact Supply terminal
Wire size 1mm ~ 4mm
2 2
A1 15
Tightening torque 0.5Nm A1 15 25
Mounting TH-35 Rail(EN60715)
Menu ok
C L N ST110
C1
220V
Standard IEC60947-1/IEC60947-2-7 A2 18 16
C1 18 15 16 A2 50/60Hz
Dimensions
18 15 16 A2 A2 18 16 28 26 Supply indication (yellow)
Output indication(red)
Front-face panel TWILIGHT SWITCH
Un:AC220V 50/60Hz
25A AC1
:DD-MM-YY, 23th.September.2013 N Sensitivity adjustment
N L1
L
C L N
L2 220V
Output - channel 2 Supply terminal A1 50/60Hz
35
25A AC1
45
90
28 25 26 A1 220-240V
B1 B2
C2 50/60Hz
28 25 26 A1
ESRD-ST1
C2
1 LCD display
C1 Sensor input terminal
C2 B1 B2
35
45
Microcontroller based
Microcontroller based Modular design,18mm wide housing
Modular design, 18mm wide housing
Possibility of 3 wire or 4 wire connection
10 operating modes
10 time ranges(1s,10s,1m,10m,1h,10h,1d,10d,ON,OFF) ON,OFF,AUTO three operation modes
ESRS-TM11/12/14/23 1 changeover contact ESRD-TSL Series Repetition accuracy<0.2%
MULTIFUNCTION TIME RELAY LED indication for power supply and relay status LCD indication for relay status
DIN-Rail mounting STAIRCASE LIGHTING TIME
DIN-Rail mounting
1h 10h 1h 10h
Inductive load,cos$=0.6@230V 650W
Repetition accuracy <0.2% 10m 1d 10m 1d
1m 10d
ON
1m 10d
OFF
Mechanical life 10 5
10s ON 10s ON
Output contacts 1 C/O 6
1s OFF 1s OFF Electrical life 10
Current rating 8A /AC1 Time range
0.5 0.6
0.5-20m
1d T1
1h 10h
Contacts capacity AC-15: 2A 10m
1m 0.3
0.4 0.7
0.8 Time adjustment: Setting accuracy ≤5%
10d
10s ON T 0.2 0.9 ×T
Insulation voltage 250V 1s OFF
0.1 1 t=10m x 0.3 = 3 min Repetition accuracy ≤0.2%
Protection degree IP20 Maximum load of illuminated switch 50mA
1h 10h 0.5 0.6
10m 1d T2 0.4 0.7
Pollution degree 3 1m 10d 0.3 0.8 Time adjustment: Reset time ≥200ms
10s ON T 0.2 0.9 ×T
Electrical life 10
5
1s OFF
0.1 1 t=1d x 0.7 = 0.7day Altitude ≤2000m
Mechanical life 10 6 Protection degree IP20
Altitude ≤2000m Wiring diagrams Pollution degree 3
A1 15 A1 15 25 Ambient temperature -5°C~+40°C 4 wire connection
Ambient temperature -5ºC~+40ºC A1 A3 15
A1 S A2 A1 S A2 AC/DC 24V A1 S A2
Time setting
Front-face panel
A3
Output indication LED(red)
Supply terminals A1,A2
A1 S A2
ESRS-TM11
28 25 26 Function selecting
Supply terminals A3
Pulse terminal A3 18 15 16 18 15 16
18 15 16
ESRS-TM11/14 ESRS-TM12 Dimensions
ESRS-TM23
Supply indication(green) RS-TSL
U
Dimensions
Multi-function
output indication(red)
Functions setting
C
D
E F
G
H
A1 S A2
FUNCTION DIAGRAM
B I FUNC A3
Time setting A J
1h 10h
10m 1d
1m 10d
T U
85.6
10s ON Multi-function
45
.5 .6
.4 .7 D
E F
G
.3 .8 C H
44.5
B I FUNC
.2 .9 ×T A J
90
1h 10h
10m 1d
.1 1 1m 10d
10s ON T
ESRS-TM11 1s
0.4
0.5 0.6
OFF
0.7
0.3 0.8
0.2 0.9 ×T ESRS-TSL
0.1 1
ESRS-TM12
30
18 15 16 49
18
18 15 16 60 65
Output contact
17.8
65