Sunteți pe pagina 1din 32

High Performance Inverter

New

F U J I E L E C T R I C I N V E RT E R S
The FRENIC-Ace Inverters are full feature drives offering great value
and maintain high performance through optimal design
for a wide range of applications for various machines and devices.

24A1-E-0042g
The Next Generation Of Inverters Have Arrived
Introducing Our New Standard Inverter!

Enjoy A Full Range Of Applications


The standard inverter for the next generation, the FRENIC-Ace, can be used
in most types of application—from fans and pumps to specialized machinery.
3-phase 400V(460V) series 3-phase 200V(230V) series 1-phase 200V series
Nominal ND rating HD rating HND rating HHD rating HND rating HHD rating HHD rating
applied Rated Rated Rated Rated Rated Rated Rated
motor Model output Model output Model output Model output Model output Model output Model output
[kW(HP*)] current current current current current current current
0.1(1/8) FRN0001E2 -2 0.8A FRN0001E2 -7 0.8A
0.2(1/4) FRN0001E2 -2 1.3A FRN0002E2 -2 1.6A FRN0002E2 -7 1.6A
0.4(1/2) FRN0002E2 -4 1.5A FRN0002E2 -2 2A FRN0004E2 -2 3A FRN0003E2 -7 3A
0.75(1) FRN0002E2 -4 2.1A FRN0002E2 -4 1.8A FRN0002E2 -4 1.8A FRN0004E2 -4 2.5A FRN0004E2 -2 3.5A FRN0006E2 -2 5A FRN0005E2 -7 5A
1.1(1.5) FRN0004E2 -4 3.4A FRN0004E2 -4 3.4A FRN0006E2 -2 6A
1.5(2) FRN0004E2 -4 4.1A FRN0006E2 -4 4.2A FRN0010E2 -2 8A FRN0008E2 -7 8A
2.2(3) FRN0006E2 -4 5.5A FRN0006E2 -4 5A FRN0006E2 -4 5A FRN0007E2 -4 5.5A FRN0010E2 -2 9.6A FRN0012E2 -2 11A FRN0011E2 -7 11A
3(4) FRN0007E2 -4 6.9A FRN0007E2 -4 6.3A FRN0007E2 -4 6.3A FRN0012E2 -2 12A
3.7(5) FRN0012E2 -4 9A FRN0020E2 -2 17.5A
5.5(7.5) FRN0012E2 -4 12A FRN0012E2 -4 11.1A FRN0012E2 -4 11.1A FRN0022E2 -4 13A FRN0020E2 -2 19.6A FRN0030E2S-2 25A
7.5(10) FRN0022E2 -4 17.5A FRN0022E2 -4 17.5A FRN0029E2 -4 18A FRN0030E2S-2 30A FRN0040E2S-2 33A
11(15) FRN0022E2 -4 21.5A FRN0029E2 -4 23A FRN0029E2 -4 23A FRN0037E2 -4 24A FRN0040E2S-2 40A FRN0056E2S-2 47A
15(20) FRN0029E2 -4 28.5A FRN0037E2 -4 31A FRN0037E2 -4 31A FRN0044E2 -4 30A FRN0056E2S-2 56A FRN0069E2S-2 60A
18.5(25) FRN0037E2 -4 37A FRN0044E2 -4 38A FRN0044E2 -4 38A FRN0059E2 -4 39A FRN0069E2S-2 69A FRN0088E2S-2 76A
22(30) FRN0044E2 -4 44A FRN0059E2 -4 45A FRN0059E2 -4 45A FRN0072E2 -4 45A FRN0088E2S-2 88A FRN0115E2S-2 90A
30(40) FRN0059E2 -4 59A FRN0072E2 -4 60A FRN0072E2 -4 60A FRN0085E2 -4 60A FRN0115E2S-2 115A
37(50) FRN0072E2 -4 72A FRN0085E2 -4 75A FRN0085E2 -4 75A FRN0105E2 -4 75A
45(60) FRN0085E2 -4 85A FRN0105E2 -4 91A FRN0105E2 -4 91A FRN0139E2 -4 91A
55(75) FRN0105E2 -4 105A FRN0139E2 -4 112A FRN0139E2 -4 112A FRN0168E2 -4 112A
75(100) FRN0139E2 -4 139A FRN0168E2 -4 150A FRN0168E2 -4 150A FRN0203E2 -4 150A
90(125) FRN0168E2 -4 168A FRN0203E2 -4 176A FRN0203E2 -4 176A FRN0240E2 -4 176A
110(150) FRN0203E2 -4 203A FRN0240E2 -4 210A FRN0240E2 -4 210A FRN0290E2 -4 210A
132(200) FRN0240E2 -4 240A FRN0290E2 -4 253A FRN0290E2 -4 253A FRN0361E2 -4 253A
160(250) FRN0290E2 -4 290A FRN0361E2 -4 304A FRN0361E2 -4 304A FRN0415E2 -4 304A
200(300) FRN0361E2 -4 361A FRN0415E2 -4 377A FRN0415E2 -4 377A FRN0520E2 -4 377A
220(350) FRN0415E2 -4 415A FRN0520E2 -4 415A FRN0520E2 -4 415A FRN0590E2 -4 415A
250(400) FRN0590E2 -4 477A
280(450) FRN0520E2 -4 520A FRN0590E2 -4 520A
315(500) FRN0590E2 -4 590A

Rating Overload current rating Max. ambient temp. Overload current rating Max. ambient temp. Overload current rating Max. ambient temp.
Overload current rating Max. ambient temp. Overload current rating Max. ambient temp. Overload current rating Max. ambient temp. Overload current rating Max. ambient temp.
condition 150% -1min, Ć& 150% -1min, Ć& 150% -1min, Ć&
120% -1min Ć& 150% -1min Ć& 120% -1min Ć& 120% -1min Ć&
200% -0.5sec 200% -0.5sec 200% -0.5sec

Fans, pumps Fans, pumps Fans, pumps

Wire drawing Wire drawing Wire drawing

Application Vertical conveyance Vertical conveyance Vertical conveyance Vertical conveyance

Winding machines Winding machines Winding machines

Printing machines Printing machines Printing machines

*HP@ 60Hz 3PH230V 3PH460V.

2
F U J I E L E C T R I C I N V E RT E R S

Customizable Logic

Major Functions
*\Z[VTPaHISLSVNPJM\UJ[PVUPZH]HPSHISLHZHZ[HUKHYKMLH[\YL-9,50*(JLOHZI\PS[PUJ\Z[VTPaHISLSVNPJM\UJ[PVUZ^P[OHTH_PT\TVM
Z[LWZPUJS\KPUNIV[OKPNP[HSHUKHUHSVNVWLYH[PVUM\UJ[PVUZNP]PUNJ\Z[VTLYZ[OLHIPSP[`[VJ\Z[VTPaL[OLPYPU]LY[LYZ·MYVTZPTWSL
SVNPJM\UJ[PVUZ[VM\SSZJHSLWYVNYHTTPUN-\QP,SLJ[YPJHSZVOHZWSHUZ[VVMMLYWYVNYHTTPUN[LTWSH[LZMVY^PYLKYH^PUNTHJOPULZOVPZ[Z
ZWPUUPUNTHJOPULZHUKV[OLYHWWSPJH[PVUZZV[OH[[OL-9,50*(JLJHUIL\ZLKHZHKLKPJH[LKW\YWVZLPU]LY[LY

6WDQGDUG0RGHO6SHFLðFDWLRQV
Example: Hoist crane application

7YVNYHTTPUN[OL-9,50*(JLTHPU\UP[^P[O[OLYLX\PYLKSVNPJMVYJVU[YVSSPUNHOVPZ[

(1) Set speed program


(2) 9LZL[[OLHSHYTI`\ZPUN[OLW\ZOI\[[VUZ^P[JO
4LJOHUPJHSSPTP[Z^P[JOM\UJ[PVU Dedicated/specialized functions for
(4) Detect load OVPZ[HWWSPJH[PVUPTWSLTLU[LKI`

&RPPRQ6SHFLðFDWLRQV
\ZPUNJ\Z[VTPaHISLSVNPJ
(5) (\[VTH[PJZWLLKKYP]L^OLUUVSVHKPZKL[LJ[LK
(6) Overload stop function

Superior Flexibility

Basic Wiring Diagram


-9,50*(JLOHZYLHKPS`H]HPSHISLPU[LYMHJLJHYKZHUK]HYPV\Z[`WLZVMÄLSKI\ZUL[^VYR[VTH_PTPaLP[ZÅL_PIPSP[`

Mounting adapter for option card


Option Category Option Name 0002 to 0044 (400V), 0059 to 0072 (400V), more than 0085 (400V)
0001 to 0069 (200V) 0069 to 0115 (200V)
RS-485 communications card
;LYTPUHSISVJR PG interface (5V) card Unnecessary

Terminal Functions
PG interface (12/15V) card
DeviceNet communication card
CC-Link communication card
PROFIBUS-DP communication card ;OLHKHW[LYPZ ;OLHKHW[LYPZ ;OLHKHW[LYPZ
Communication *1
EtherNet/IP communication card mounted on the mounted inside of mounted inside of
7YVÄ5L[9;JVTT\UPJH[PVUJHYK front side of the inverter. the inverter. the inverter.
CANopen communication card (OPC-E2-ADP1) (OPC-E2-ADP2) (OPC-E2-ADP3) External Dimensions
Digital Input / Output interface card
Input / Output interface *1
Analog Output interface interface card
(]HPSHISLI`[OLJVTIPUH[PVU\ZLVM[OLTV\U[PUNHKHW[LY

Wide Variety Of Functions As A Standard Feature


Options

Sensorless dynamic torque vector control


Motor vector control with PG (with optional card)
Synchronous motor with sensorless vector control
2-channel on-board RS485 communications port
Standard CANopen compatibility
Removable keypad device
Removable control terminal block board

3
Multi-Function Keypad (option)
FRENIC-Ace has two different multi-function keypads available
Multi-function keypad with LCD display: Enhanced HMI functionality
2L`WHK^P[O<:)WVY[!*VUULJ[[VHJVTW\[LYMVYTVYLLMÄJPLU[VWLYH[PVUZL[\W[YV\ISLZOVV[PUNTHPU[LUHUJLL[J

LAN cable

USB–USBminiB cable

Keypad with USB port


Multi-function keypad
with LCD screen

Functional Safety
FRENIC-Ace is equipped with STO functional safety function as a standard. Therefore output circuit magnetic contactors are not required
for safe stop implementation. Enhanced standard features position FRENIC-Ace ahead of its class (Safety input: 2CH, output: 1CH).

Complies with

EN ISO 13849-1: 2008, Cat.3 / PL=e IEC/EN 61800-5-2: 2007 SIL3 (Safety feature: STO)
IEC/EN 60204-1: 2005/2006 Stop category 0 IEC/EN 62061: 2005 SIL3
IEC/EN 61508-1 to -7: 2010 SIL3

@LHYZ3PML[PTL+LZPNU
FRENIC-Ace components have a design life of ten years.
A longer maintenance cycle also helps to reduce running costs.

Main circuit capacitor 10 years *1


Electrolytic capacitors on PCB 10 years *1
Cooling fan 10 years *1
Design life *2
Ambient temperature +40°C (104°F)
Life conditions  //+ZWLJPÄJH[PVUZ
Load rate
 /5+/+5+ZWLJPÄJH[PVUZ
5+ZWLJPÄJH[PVUZOH]LHYH[LKJ\YYLU[VM[^VZPaLZOPNOLY[OHU//+ZWLJPÄJH[PVUZZV[OLSPMLPZ`LHYZ
*2 The designed lives are the calculated values and not the guaranted ones.

:[HUKHYKZ Global Compliance


RoHS Directive Standard compliance
:[HUKHYKJVTWSPHUJL^P[O,\YVWLHUYLN\SH[PVUZ[OH[SPTP[[OL\ZLVMZWLJPÄJOHaHYKV\ZZ\IZ[HUJLZ9V/:
EC Directives (CE Mark) <3:[HUKHYKJ<3*LY[PÄLK

<Six hazardous Lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyl


substances> (PBB), polybrominated biphenyl ether (PBDE)

2VYLH*LY[PÄJH[PVU4HYR2*4HYR
<About RoHS> Directive 2002/95/EC, issued by the European Parliament and European
*V\UJPSSPTP[Z[OL\ZLVMZWLJPÄJOHaHYKV\ZZ\IZ[HUJLZPULSLJ[YPJHSHUKLSLJ[YVUPJKL]PJLZ

* Only FRN E2S- G and FRN E2S- K


F U J I E L E C T R I C I N V E RT E R S

:[HUKHYK4VKLS:WLJPÄJH[PVUZ

Major Functions
;OYLLWOHZL=JSHZZZLYPLZ
Items :WLJPÄJH[PVUZ
FRN E2S-4GA, FRN E2S-4GB,
FRN E2S-4GB,
FRN E2S-4GB, FRN E2S-4E,
Type FRN E2S-4K
FRN E2S-4K FRN E2S-4K
0002 0004 0006 0007 0012 0022 0029 0037 0044 0059 0072

6WDQGDUG0RGHO6SHFLðFDWLRQV
ND 0.75(1) 1.5(2) 2.2(3) 3.0(4) 5.5(7.5) 11(15) 15(20) 18.5(25) 22(30) 30(40) 37(50)
HD 0.75(1) 1.1(1.5) 2.2(3) 3.0(4) 5.5(7.5) 7.5(10) 11(15) 15(20) 18.5(25) 22(30) 30(40)
Nominal applied motor *1 [kW(HP)]
HND 0.75(1) 1.1(1.5) 2.2(3) 3.0(4) *10 5.5(7.5) *10 7.5(10) 11(15) 15(20) 18.5(25) 22(30) 30(40)
HHD 0.4(1/2) 0.75(1) 1.5(2) 2.2(3) 3.7(5) 5.5(7.5) 7.5(10) 11(15) 15(20) 18.5(25) 22(30)
ND 1.6 3.1 4.2 5.3 9.1 16 22 28 34 45 55
HD 1.4 2.6 3.8 4.8 8.5 13 18 24 29 34 46
Rated capacity [kVA] *2
HND 1.4 2.6 3.8 4.8 *10 8.5 *10 13 18 24 29 34 46
HHD 1.1 1.9 3.2 4.2 6.9 9.9 14 18 23 30 34

&RPPRQ6SHFLðFDWLRQV
Rated voltage [V] *3 Three-phase 380 to 480V (With AVR)
ND 2.1 4.1 5.5 6.9 12 21.5 28.5 37.0 44.0 59.0 72.0
Output ratings
HD 1.8 3.4 5.0 6.3 11.1 17.5 23.0 31.0 38.0 45.0 60.0
Rated current [A] *4
HND 1.8 3.4 5.0 6.3*10 11.1*10 17.5 23.0 31.0 38.0 45.0 60.0
HHD 1.5 2.5 4.2 5.5 9.0 13.0 18.0 24.0 30.0 39.0 45.0
ND, HND 120% of nominal current for 1min
Overload capability HD 150% of nominal current for 1min
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s

Basic Wiring Diagram


Main power supply Three-phase 380 to 480V (With AVR)
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)
ND 2.7 4.8 7.3 11.3 16.8 33.0 43.8 52.3 60.6 77.9 94.3
Rated current HD 2.7 3.9 7.3 11.3 16.8 23.2 33.0 43.8 52.3 60.6 77.9
without DCR *5
[A] HND 2.7 3.9 7.3 11.3 *10
16.8 *10
23.2 33.0 43.8 52.3 60.6 77.9
HHD 1.7 3.1 5.9 8.2 13.0 17.3 23.2 33.0 43.8 52.3 60.6
ND 1.5 2.9 4.2 5.8 10.1 21.1 28.8 35.5 42.2 57.0 68.5
Input ratings
Rated current HD 1.5 2.1 4.2 5.8 10.1 14.4 21.1 28.8 35.5 42.2 57.0

Terminal Functions
with DCR *5 [A] HND 1.5 2.1 4.2 5.8 *10 10.1*10 14.4 21.1 28.8 35.5 42.2 57.0
HHD 0.85 1.6 3.0 4.4 7.3 10.6 14.4 21.1 28.8 35.5 42.2
ND 1.1 2.1 3.0 4.1 7.0 15 20 25 29 39 47
Required power
HD 1.1 1.5 3.0 4.1 7.0 10 15 20 25 29 39
supply capacity *6
HND 1.1 1.5 3.0 4.1*10 7.0 *10 10 15 20 25 29 39
[kVA]
HHD 0.6 1.2 2.1 3.1 5.1 7.3 10 15 20 25 29
ND 53% 50% 48% 29% 27% 12%

External Dimensions
HD 53% 68% 48% 29% 27% 15%
Braking torque *7 [%]
HND 53% 68% 48% 29%*10 27%*10 15%
HHD 100% 70% 40% 20%
Braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Built-in
Minimum connectable resistance [ohm] 200 160 130 80 60 40 34.4 16
Braking resistor Option
DC reactor (DCR) Option
Enclosure (IEC60529) IP20, UL open type
Options

Cooling method Natural cooling Fan cooling


Mass [kg] 1.2 1.5 1.5 1.6 1.9 5.0 5.0 8.0 9.0 9.5 10
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the *5 The value is calculated assuming that the inverter is connected with a power supply with
rating capacity(kW) is enough but also inverter output current is larger than selected the the capacity of 500 kVA
motor's nominal current. (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*2 Rated capacity is calculated by assuming the output rated voltage as 440 V. Be sure to use the DCR when applicable motor capacity is 75kW or above.
*3 The output voltage cannot exceed the power supply voltage. *6 Obtained when a DC reactor (DCR) is used.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to  (]LYHNL IYHRPUN [VYX\L MVY [OL TV[VY Y\UUPUN HSVUL 0[ ]HYPLZ ^P[O [OL LMÄJPLUJ` VM
be necessary to derate their nominal current. the motor.)
HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average
type 0203 to 0590 : 6kHz voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor
HND spec.---type 0002 to 0012 : 8kHz, type 0022 to 0059 : 10kHz, (ACR).
type 0072 to 0168 : 6kHz, type 0203 to 0590 : 4kHz *10 HND spec. of the type 0007 and 0012: allowable ambient temperature 40 °C (+104 °F)
HD,ND spec.---All type : 4kHz or less.
The rated output current at HD/ND spec. is decreased 2% for every 1 °C (1.8 °F) when The rated output current at HND spec. is decreased 1% for every 1 °C (1.8 °F) when
ambient temperature is +40 °C (+104 °F) or more. ambient temperature is +40 °C (+104 °F) or more.

5
:[HUKHYK4VKLS:WLJPÄJH[PVUZ
Three phase 400V class series
Items :WLJPÄJH[PVUZ
FRN E2S-4GB,
FRN E2S-4GB
Type FRN E2S-4K
0085 0105 0139 0168 0203 0240 0290 0361 0415 0520 0590
ND 45(60) 55(75) 75(100) 90(125) 110(150) 132(200) 160(250) 200(300) 220(350) 280(450) 315(500)
HD 37(50) 45(60) 55(75) 75(100) 90(125) 110(150) 132(200) 160(250) 200(300) 220(350) 250(400)
Nominal applied motor *1 [kW(HP)]
HND 37(50) 45(60) 55(75) 75(100) 90(125) 110(150) 132(200) 160(250) 200(300) 220(350) 280(450)
HHD 30(40) 37(50) 45(60) 55(75) 75(100) 90(125) 110(150) 132(200) 160(250) 200(300) 220(350)
ND 65 80 106 128 155 183 221 275 316 396 450
HD 57 69 85 114 134 160 193 232 287 316 364
Rated capacity [kVA] *2
HND 57 69 85 114 134 160 193 232 287 316 396
HHD 46 57 69 85 114 134 160 193 232 287 316
Rated voltage [V] *3 Three-phase 380 to 480V (With AVR)
ND 85.0 105 139 168 203 240 290 361 415 520 590
Output ratings
HD 75.0 91.0 112 150 176 210 253 304 377 415 477
Rated current [A] *4
HND 75.0 91.0 112 150 176 210 253 304 377 415 520
HHD 60.0 75.0 91.0 112 150 176 210 253 304 377 415
ND, HND 120% of nominal current for 1min
Overload capability HD 150% of nominal current for 1min
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Three-phase 380 to 440V, 50Hz *9
Main power supply Three-phase 380 to 480V, 50/60Hz
Three-phase 380 to 480V, 60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%) *8
ND 114 140 - - - - - - - - -
Rated current HD 94.3 114 140 - - - - - - - -
without DCR *5
[A] HND 94.3 114 140 - - - - - - - -
HHD 77.9 94.3 114 140 - - - - - - -
ND 83.2 102 138 164 201 238 286 357 390 500 559
Input ratings
Rated current HD 68.5 83.2 102 138 164 201 238 286 357 390 443
with DCR *5
[A] HND 68.5 83.2 102 138 164 201 238 286 357 390 500
HHD 57.0 68.5 83.2 102 138 164 201 238 286 357 390
ND 58 71 96 114 139 165 199 248 271 347 388
Required power
HD 47 58 71 96 114 140 165 199 248 271 307
supply capacity *6
HND 47 58 71 96 114 140 165 199 248 271 347
[kVA]
HHD 39 47 58 71 96 114 140 165 199 248 271
ND 5 to 9%
HD 7 to 12%
Braking torque *7 [%]
HND 7 to 12%
HHD 10 to 15%
Braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Option
Minimum connection resistance[ohm] - - - - - - - - - - -
Braking resistor Option
DC reactor (DCR) Option
Enclosure (IEC60529) IP00, UL open type
Cooling method Fan cooling
Mass [kg] 25 26 30 33 40 62 63 95 96 130 140
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough
but also inverter output current is larger than selected the motor's nominal current.
*2 Rated capacity is calculated by assuming the output rated voltage as 440 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz
HND spec.---type 0002 to 0012 : 8kHz, type 0022 to 0059 : 10kHz, type 0072 to 0168 : 6kHz, type 0203 to 0590 : 4kHz
HD,ND spec.---All type : 4kHz
The rated output current at HD/ND spec. is decreased 2% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more.
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
Be sure to use the DCR when applicable motor capacity is 75kW or above.
*6 Obtained when a DC reactor (DCR) is used.
 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY
*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).
  ;OL=JSHZZZLYPLZ^P[O[`WLVYHIV]LPZLX\PWWLK^P[OHZL[VMZ^P[JOPUNJVUULJ[VYZTHSL^OPJOZOV\SKILJVUÄN\YLKHJJVYKPUN[V[OLWV^LYZV\YJL]VS[HNLHUKMYLX\LUJ`

6
F U J I E L E C T R I C I N V E RT E R S

:[HUKHYK4VKLS:WLJPÄJH[PVUZ

Major Functions
Three phase 200V class series
Items :WLJPÄJH[PVUZ
FRN E2S-2GA, FRN E2S-2GB,
Type FRN E2S-2GB FRN E2S-2K
0001 0002 0004 0006 0010 0012 0020 0030 0040 0056 0069 0088 0115
HND 0.2(1/4) 0.4(1/2) 0.75(1) 1.1(1.5) 2.2(3) 3.0(4) *10 5.5(7.5) *10 7.5(10) 11(15) 15(20) 18.5(25) 22(30) 30(40)

6WDQGDUG0RGHO6SHFLðFDWLRQV
Nominal applied motor *1 [kW(HP)]
HHD 0.1(1/8) 0.2(1/4) 0.4(1/2) 0.75(1) 1.5(2) 2.2(3) 3.7(5) 5.5(7.5) 7.5(10) 11(15) 15(20) 18.5(25) 22(30)
HND 0.5 0.8 1.3 2.3 3.7 4.6 *10 7.5 *10 11 15 21 26 34 44
Rated capacity [kVA] *2
HHD 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 18 23 29 34
Rated voltage [V] *3 Three-phase 200 to 240V (With AVR)
Output ratings HND 1.3 2.0 3.5 6.0 9.6 12*10 19.6 *10 30 40 56 69 88 115
Rated current [A] *4
HHD 0.8 1.6 3.0 5.0 8.0 11 17.5 25 33 47 60 76 90
HND 120% of nominal current for 1min
Overload capability
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s

&RPPRQ6SHFLðFDWLRQV
Main power supply Three-phase 200 to 240V, 50/60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)
Rated current HND 1.8 2.6 4.9 6.7 12.8 17.9 *10 31.9 *10 42.7 60.7 80.0 97.0 112 151
without DCR *5 [A] HHD 1.1 1.8 3.1 5.3 9.5 13.2 22.2 31.5 42.7 60.7 80.0 97.0 112
Input ratings
Rated current HND 0.93 1.6 3.0 4.3 8.3 11.7*10 19.9 *10 28.8 42.2 57.6 71.0 84.4 114
with DCR *5 [A] HHD 0.57 0.93 1.6 3.0 5.7 8.3 14.0 21.1 28.8 42.2 57.6 71.0 84.4
Required power HND 0.4 0.6 1.1 1.5 2.9 4.1*10 6.9 *10 10 15 20 25 30 40
supply capacity *6 [kVA] HHD 0.2 0.4 0.6 1.1 2.0 2.9 4.9 7.3 10 15 20 25 30

Basic Wiring Diagram


HND 75% 53% 68% 48% 29%*10 27%*10 15%
Braking torque *7 [%]
HHD 150% 100% 70% 40% 20%
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
Braking DC braking
Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Built-in
Minimum connection resistance[ohm] 100 40 33 20 15 10 8.6 4
Braking resistor Option
DC reactor (DCR) Option

Terminal Functions
Enclosure (IEC60529) IP20, UL open type
Cooling method Naturalural cooling Fan cooling
Mass [kg] 0.5 0.5 0.6 0.8 1.5 1.5 1.8 5.0 5.0 8.0 9.0 9.5 10
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough
but also inverter output current is larger than selected the motor's nominal current.
*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.---type 0001 to 0020 : 8kHz, type 0030 to 0115 : 10kHz,
HND spec.---type 0001 to 0020 : 4kHz, type 0030 to 0069 : 10kHz, type 0088,0115 : 4kHz

External Dimensions
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*6 Obtained when a DC reactor (DCR) is used.
 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY
*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3)
If this value is 2 to 3%, use an optional AC reactor (ACR).
*10 HND spec. of the type 0012 and 0020: allowable ambient temperature 40 °C (+104 °F) or less.
The rated output current at HND spec. is decreased 1% for every 1 °C (1.8 °F) when ambient temperature is +40 °C (+104 °F) or more.
Options

7
:[HUKHYK4VKLS:WLJPÄJH[PVUZ
Single phase 200V class series (Basic Type)
Items :WLJPÄJH[PVUZ
FRN E2S-7GA, FRN E2S-7GB
Type
0001 0002 0003 0005 0008 0011
Nominal applied motor *1 [kW(HP)] HHD 0.1(1/8) 0.2(1/4) 0.4(1/2) 0.75(1) 1.5(2) 2.2(3)
Rated capacity [kVA] *2 HHD 0.3 0.6 1.1 1.9 3.0 4.2
Rated voltage [V] *3 Three-phase 200 to 240V (With AVR)
Output ratings
Rated current [A] *4 HHD 0.8 1.6 3.0 5.0 8.0 11
Overload capability HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Main power supply Three-phase 200 to 240V, 50/60Hz
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)
Rated current
HHD 1.8 3.3 5.4 9.7 16.4 24.8
without DCR *5 [A]
Input ratings
Rated current
HHD 1.1 2.0 3.5 6.4 11.6 17.5
with DCR *5 [A]
Required power
HHD 0.3 0.4 0.7 1.3 2.4 3.5
supply capacity *6 [kVA]
Braking torque *7 [%] HHD 150% 100% 70% 40%
DC braking Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
Braking level: 0 to 100% (HHD spec.) of nominal current
Braking
Braking chopper Built-in
Minimum connection resistance [ohm] 100 40
Braking resistor Option
DC reactor (DCR) Option
Enclosure (IEC60529) IP20, UL open type
Cooling method Naturalural cooling Fan cooling
Mass [kg] 0.5 0.5 0.6 0.9 1.6 1.8
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough
but also inverter output current is larger than selected the motor's nominal current.
*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.---type 0001 to 0011 : 8kHz
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*6 Obtained when a DC reactor (DCR) is used.
 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY

8
F U J I E L E C T R I C I N V E RT E R S

,4*-PS[LY)\PS[PU;`WL:WLJPÄJH[PVUZ

Major Functions
Three phase 400V class series
Items :WLJPÄJH[PVUZ
FRN E2E-4GA FRN E2E-4E
Type
0002 0004 0006 0007 0012 0022 0029 0037 0044 0059 0072
ND 0.75 1.5 2.2 3.0 5.5 11 15 18.5 22 30 37
HD 0.75 1.1 2.2 3.0 5.5 7.5 11 15 18.5 22 30

6WDQGDUG0RGHO6SHFLðFDWLRQV
Nominal applied motor *1 [kW]
HND 0.75 1.1 2.2 3.0 *9 5.5 *9 7.5 11 15 18.5 22 30
HHD 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
ND 1.6 3.1 4.2 5.3 9.1 16 22 28 34 45 55
HD 1.4 2.6 3.8 4.8 8.5 13 18 24 29 34 46
Rated capacity [kVA] *2
HND 1.4 2.6 3.8 4.8 *9 8.5 *9 13 18 24 29 34 46
HHD 1.1 1.9 3.2 4.2 6.9 9.9 14 18 23 30 34
Rated voltage [V] *3 Three-phase 380 to 480V (With AVR)
ND 2.1 4.1 5.5 6.9 12 21.5 28.5 37.0 44.0 59.0 72.0

&RPPRQ6SHFLðFDWLRQV
Output ratings
HD 1.8 3.4 5.0 6.3 11.1 17.5 23.0 31.0 38.0 45.0 60.0
Rated current [A] *4
HND 1.8 3.4 5.0 6.3*9 11.1*9 17.5 23.0 31.0 38.0 45.0 60.0
HHD 1.5 2.5 4.2 5.5 9.0 13.0 18.0 24.0 30.0 39.0 45.0
ND, HND 120% of nominal current for 1min
Overload capability HD 150% of nominal current for 1min
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Main power supply Three-phase 380 to 480V, 50/60Hz
Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)

Basic Wiring Diagram


Voltage/frequency variations
ND 2.7 4.8 7.3 11.3 16.8 33.0 43.8 52.3 60.6 77.9 94.3
Rated current HD 2.7 3.9 7.3 11.3 16.8 23.2 33.0 43.8 52.3 60.6 77.9
without DCR *5 [A] HND 2.7 3.9 7.3 11.3*9 16.8 *9 23.2 33.0 43.8 52.3 60.6 77.9
HHD 1.7 3.1 5.9 8.2 13.0 17.3 23.2 33.0 43.8 52.3 60.6
ND 1.5 2.1 4.2 5.8 10.1 21.1 28.8 35.5 42.2 57.0 68.5
Input ratings
Rated current HD 1.5 2.1 4.2 5.8 10.1 14.4 21.1 28.8 35.5 42.2 57.0
with DCR *5 [A] HND 1.5 2.1 4.2 5.8 *9 10.1*9 14.4 21.1 28.8 35.5 42.2 57.0
HHD 0.85 1.6 3.0 4.4 7.3 10.6 14.4 21.1 28.8 35.5 42.2

Terminal Functions
ND 1.1 1.5 3.0 4.1 7.0 15 20 25 29 39 47
Required power
HD 1.1 1.5 3.0 4.1 7.0 10 15 20 25 29 39
supply capacity *6
HND 1.1 1.5 3.0 4.1*9 7.0 *9 10 15 20 25 29 39
[kVA]
HHD 0.6 1.2 2.1 3.1 5.1 7.3 10 15 20 25 29
ND 53% 50% 48% 29% 27% 12%
HD 53% 68% 48% 29% 27% 15%
Braking torque *7 [%]
HND 53% 68% 48% 29%*9 27%*9 15%

External Dimensions
HHD 100% 70% 40% 20%
Braking Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Built-in
Minimum connection resistance [ohm] 200 160 130 80 60 40 34.4 16
Braking resistor Option
Compliant with EMC Directives, Compliant with EMC Directives,
,4*ÄS[LY Emission: Category C2. Immunity: Category C3 (2nd Env.) Emission: Category C3. Immunity:
(EN61800-3: 2004)(Pending) Category C3(2nd Env.)(EN61800-3:2004)
DC reactor (DCR) Option
Options

Enclosure (IEC60529) IP20, UL open type


Cooling method Natural cooling Fan cooling
Mass [kg] 1.5 1.8 2.3 2.3 2.4 6.5 6.5 11.2 11.2 10.5 11.2
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) *5 The value is calculated assuming that the inverter is connected with a power supply with the
is enough but also inverter output current is larger than selected the motor's nominal current. capacity of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA)
*2 Rated capacity is calculated by assuming the output rated voltage as 440 V. and %X is 5%.Be sure to use the DCR when applicable motor capacity is 75kW or above.
*3 Output voltage cannot exceed the power supply voltage. *6 Obtained when a DC reactor (DCR) is used.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their *7 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY
nominal current. *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3)
HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz If this value is 2 to 3%, use an optional AC reactor (ACR).
HND spec.---type 0002 to 0006 : 8kHz, type 0007 to 0012 : 4kHz, type 0022 to 0168 : 6kHz, type 0203 to 0590 : 4kHz *9 /5+ZWLJVM[OL[`WLHUK!HSSV^HISLHTIPLU[[LTWLYH[\YL͵‡-VYSLZZ
HD,ND spec.---All type : 4kHz  ;OLYH[LKV\[W\[J\YYLU[H[/5+ZWLJPZKLJYLHZLK MVYL]LY`͵‡-^OLUHTIPLU[
[LTWLYH[\YLPZ͵‡-VYTVYL

9
,4*-PS[LY)\PS[PU;`WL:WLJPÄJH[PVUZ
Three phase 400V class series
Items :WLJPÄJH[PVUZ
FRN E2E-4E
Type
0085 0105 0139 0168 0203 0240 0290 0361 0415 0520 0590
ND 45 55 75 90 110 132 160 200 220 280 315
HD 37 45 55 75 90 110 132 160 200 220 250
Nominal applied motor *1 [kW]
HND 37 45 55 75 90 110 132 160 200 220 280
HHD 30 37 45 55 75 90 110 132 160 200 220
ND 65 80 106 128 155 183 221 275 316 396 450
HD 57 69 85 114 134 160 193 232 287 316 364
Rated capacity [kVA] *2
HND 57 69 85 114 134 160 193 232 287 316 396
HHD 46 57 69 85 114 134 160 193 232 287 316
Rated voltage [V] *3 Three-phase 380 to 480V (With AVR)
ND 85.0 105 139 168 203 240 290 361 415 520 590
Output ratings
HD 75.0 91.0 112 150 176 210 253 304 377 415 477
Rated current [A] *4
HND 75.0 91.0 112 150 176 210 253 304 377 415 520
HHD 60.0 75.0 91.0 112 150 176 210 253 304 377 415
ND, HND 120% of nominal current for 1min
Overload capability HD 150% of nominal current for 1min
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Three-phase 380 to 440V, 50Hz
Main power supply Three-phase 380 to 480V, 50/60Hz
Three-phase 380 to 480V, 60Hz*9
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)
ND 114 140 - - - - - - - - -
Rated current HD 94.3 114 140 - - - - - - - -
without DCR *5 [A] HND 94.3 114 140 - - - - - - - -
HHD 77.9 94.3 114 140 - - - - - - -
ND 83.2 102 138 164 201 238 286 357 390 500 559
Input ratings
Rated current HD 68.5 83.2 102 138 164 201 238 286 357 390 443
with DCR *5 [A] HND 68.5 83.2 102 138 164 201 238 286 357 390 500
HHD 57.0 68.5 83.2 102 138 164 201 238 286 357 390
ND 58 71 96 114 139 165 199 248 271 347 388
Required power
HD 47 58 71 96 114 140 165 199 248 271 307
supply capacity *6
HND 47 58 71 96 114 140 165 199 248 271 347
[kVA]
HHD 39 47 58 71 96 114 140 165 199 248 271
ND 5 to 9%
HD 7 to 12%
Braking torque *7 [%]
HND 7 to 12%
HHD 10 to 15%
Braking
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking level: 0 to 60% (ND spec.), 0 to 80% (HD/HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Option
Minimum connection resistance[ohm] - - - - - - - - - - -
Braking resistor Option
,4*ÄS[LY *10 Compliant with EMC Directives, Emission and Immunity: Category C3 (2nd Env.) (EN61800-3:2004)
DC reactor (DCR) Option
Enclosure (IEC60529) IP00, UL open type
Cooling method Fan cooling
Mass [kg] 26 27 31 33 40 62 63 95 96 130 140
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) *5 The value is calculated assuming that the inverter is connected with a power supply with the capacity
is enough but also inverter output current is larger than selected the motor's nominal current. of 500 kVA (or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*2 Rated capacity is calculated by assuming the output rated voltage as 440 V. Be sure to use the DCR when applicable motor capacity is 75kW or above.
*3 Output voltage cannot exceed the power supply voltage. *6 Obtained when a DC reactor (DCR) is used.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their *7 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY
nominal current. *8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V)
HHD spec.---type 0002 to 0012 : 8kHz, type 0022 to 0168 : 10kHz, type 0203 to 0590 : 6kHz × 67 (IEC 61800 - 3) If this value is 2 to 3%, use an optional AC reactor (ACR).
HND spec.---type 0002 to 0012 : 8kHz, type 0022 to 0059 : 10kHz, type 0072 to 0168 : 6kHz, type 0203 to 0590 : 4kHz *9 /5+ZWLJVM[OL[`WLHUK!HSSV^HISLHTIPLU[[LTWLYH[\YL͵‡-VYSLZZ
HD,ND spec.---All type : 4kHz  ;OLYH[LKV\[W\[J\YYLU[H[/5+ZWLJPZKLJYLHZLK MVYL]LY`͵‡-^OLUHTIPLU[
 ;OLYH[LKV\[W\[J\YYLU[H[/+5+ZWLJPZKLJYLHZLK MVYL]LY`‡*‡-^OLUHTIPLU[[LTWLYH[\YLPZ‡* [LTWLYH[\YLPZ͵‡-VYTVYL
‡-VYTVYL

10
F U J I E L E C T R I C I N V E RT E R S

,4*-PS[LY)\PS[PU;`WL:WLJPÄJH[PVUZ

Major Functions
Three phase 200V class series
Items :WLJPÄJH[PVUZ
FRN E2E-2GA
Type
0001 0002 0004 0006 0010 0012 0020
HND 0.2 0.4 0.75 1.1*9 2.2 3.0 *9 5.5 *9
Nominal applied motor *1 [kW]
HHD 0.1 0.2 0.4 0.75 1.5 2.2 3.7

6WDQGDUG0RGHO6SHFLðFDWLRQV
HND 0.5 0.8 1.3 2.3*9 3.7 4.6 *9 7.5 *9
Rated capacity [kVA] *2
HHD 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Rated voltage [V] *3 Three-phase 200 to 240V (With AVR)
Output ratings HND 1.3 2.0 3.5 6.0 9.6 12*9 19.6 *9
Rated current [A] *4
HHD 0.8 1.6 3.0 5.0 8.0 11 17.5
HND 120% of nominal current for 1min
Overload capability
HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Main power supply Three-phase 200 to 240V, 50/60Hz

&RPPRQ6SHFLðFDWLRQV
Voltage/frequency variations Voltage: +10 to -15% (Voltage unbalance:2% or less *8, Frequency: +5 to -5%)
Rated current HND 1.8 2.6 4.9 6.7*9 12.8 17.9 *9 28.5 *9
without DCR *5 [A] HHD 1.1 1.8 3.1 5.3 9.5 13.2 22.2
Input ratings
Rated current HND 0.93 1.6 3.0 4.3*9 8.3 11.7*9 19.9 *9
with DCR *5 [A] HHD 0.57 0.93 1.6 3.0 5.7 8.3 14.0
Required power HND 0.4 0.6 1.1 1.5 *9 2.9 4.1*9 6.9 *9
supply capacity *6 [kVA] HHD 0.2 0.4 0.6 1.1 2.0 2.9 4.9
HND 53% 68%*9 48% 29%*9 27%*9

Basic Wiring Diagram


75%
Braking torque *7 [%]
HHD 150% 100% 70% 40%
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking Braking level: 0 to 80% (HND spec.), 0 to 100% (HHD spec.) of nominal current
Braking chopper Built-in
Minimum connection resistance [ohm] 100 40 33
Braking resistor Option
,4*ÄS[LY Compliant with EMC Directives, Emission: Category C2. Immunity: Category C3 (2nd Env.) (EN61800-3: 2004)
DC reactor (DCR) Option

Terminal Functions
Enclosure (IEC60529) IP20, UL open type
Cooling method Naturalural cooling Fan cooling
Mass [kg] 0.6 0.6 0.7 0.9 2.2 2.3 2.3
*1 Fuji 4-pole standard motor
*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.---type 0001 to 0020 : 8kHz
HND spec.---type 0001 to 0020 : 4kHz
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA

External Dimensions
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*6 Obtained when a DC reactor (DCR) is used.
 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY
*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3)
If this value is 2 to 3%, use an optional AC reactor (ACR).
  /5+ZWLJVM[OL[`WLHUK!HSSV^HISLHTIPLU[[LTWLYH[\YL͵‡-VYSLZZ
 ;OLYH[LKV\[W\[J\YYLU[H[/5+ZWLJPZKLJYLHZLK MVYL]LY`͵‡-^OLUHTIPLU[[LTWLYH[\YLPZ͵‡-VYTVYL
Options

11
,4*-PS[LY)\PS[PU;`WL:WLJPÄJH[PVUZ
Single phase 200V class series
Items :WLJPÄJH[PVUZ
FRN E2E-7GA
Type
0001 0002 0003 0005 0008 0011
Nominal applied motor *1 [kW] HHD 0.1 0.2 0.4 0.75 1.5 2.2
Rated capacity [kVA] *2 HHD 0.3 0.6 1.1 1.9 3.0 4.2
Rated voltage [V] *3 Three-phase 200 to 240V (With AVR)
Output ratings
Rated current [A] *4 HHD 0.8 1.6 3.0 5.0 8.0 11
Overload capability HHD 150% of nominal current for 1min or 200% of nominal current for 0.5s
Main power supply Single-phase 200 to 240V,50/60Hz
Voltage: +10 to -10%
Voltage/frequency variations
Frequency: +5 to -5%
Rated current
HHD 1.8 3.3 5.4 9.7 16.4 24.8
without DCR *5 [A]
Input ratings
Rated current
HHD 1.1 2.0 3.5 6.4 11.6 17.5
with DCR *5 [A]
Required power
HHD 0.3 0.4 0.7 1.3 2.4 3.5
supply capacity *6 [kVA]
Braking torque *7 [%] HHD 150% 100% 70% 40%
Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s,
DC braking
Braking level: 0 to 100% (HHD spec.) of nominal current
Braking
Braking chopper Built-in
Minimum connectable resistance [ohm] 100 40
Braking resistor Option
Compliant with EMC Directives,
Emission: Category C2.
,4*ÄS[LY
Immunity: Category C3 (2nd Env.)
(EN61800-3:2004)
DC reactor (DCR) Option
Enclosure (IEC60529) IP20, UL open type
Cooling method Naturalural cooling Fan cooling
Mass [kg] 0.6 0.6 0.7 1.1 2.3 2.3
*1 Fuji 4-pole standard motor. At the selection of the inverter rating, consider not only the rating capacity (kW) is enough but also inverter output current is larger than selected the motor's
nominal current.
*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, the inverter is sure to be necessary to derate their nominal current.
HHD spec.---type 0001 to 0011:8 kHz
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 times the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
*6 Obtained when a DC reactor (DCR) is used.
 (]LYHNLIYHRPUN[VYX\LMVY[OLTV[VYY\UUPUNHSVUL0[]HYPLZ^P[O[OLLMÄJPLUJ`VM[OLTV[VY

12
F U J I E L E C T R I C I N V E RT E R S

*VTTVU:WLJPÄJH[PVUZ

Major Functions
Items :WLJPÄJH[PVUZ Remarks
- HHD/HND/HD spec.: 25 to 500 Hz variable
(V/f control mode, Magnetic pole position sensorless vector control mode)
Maximum frequency IMPG-VC
(Up to 200 Hz under vector control with speed sensor)
- ND spec.: 25 to 120 Hz variable (all control mode)
Base frequency 25 to 500 Hz variable (in conjunction with the maximum frequency)
0.1 to 60.0 Hz variable
Starting frequency IMPG-VC

6WDQGDUG0RGHO6SHFLðFDWLRQV
(0.0 Hz under vector control with speed sensor)
Three phase 400V class
- Type 0002 to 0059:
- 0.75 to 16kHz variable (HHD/HND/HD spec.)
- 0.75 to 10kHz variable (ND spec.)
- Type 0072 to 0168:
- 0.75 to 16kHz variable (HHD spec.)
- 0.75 to 10kHz variable (HND/HD spec.)
- 0.75 to 6kHz variable (ND spec.)
Carrier frequency
- Type 0203 or above type of capacity:
- 0.75 to 10kHz variable (HHD spec.)

&RPPRQ6SHFLðFDWLRQV
- 0.75 to 6kHz variable (HND/HD/ND spec.)
Three phase 200V class
- Type 0030,0040,0056,0069
- 0.75 to 16kHz variable (HHD/HND/ spec.)
- Type 0012 and 0020:
Output

- 0.75 to 16kHz variable (HHD spec.)


- 0.75 to 10kHz variable (ND spec.)
- Type 0115:
- 0.75 to 16kHz variable (HHD spec.)
- 0.75 to 10kHz variable (HND spec.)
Single phase 200V class

Basic Wiring Diagram


- Type 0001 to 0011
- 0.75 to 16kHz variable (HHD spec.)
Note: Carrier frequency drops automatically to protect the inverter depending on environmental temperature and
output current. (This auto drop function can be canceled.)
Output frequency - Analog setting: ±0.2% of maximum frequency 25±10°C (77±18°F)
accuracy (Stability) - Keypad setting: ±0.01% of maximum frequency -10 to +50°C (14 to 122°F)
- Analog setting: 0.05% of maximum frequency
Frequency setting
- Keypad setting: 0.01 Hz (99.99 Hz or less), 0.1 Hz (100.0 to 500.0 Hz)
resolution
3PURZL[[PUN! VMTH_PT\TMYLX\LUJ`VY/aÄ_LK
- 1 : 1500 (Minimum speed : Nominal speed, 4-pole, 1 to 1500 rpm) IMPG-VC
Speed control range - 1 : 100 (Minimum speed : Nominal speed, 4-pole, 15 to 1500 rpm) IMPG-VF

Terminal Functions
- 1 : 10 (Minimum speed : Nominal speed, 6-pole, 180 to 1800 rpm) PM-SVC
- Analog setting: ±0.2% of maximum frequency or below 25 ±10°C (77±18°F)
IMPG-VC
Speed control - Digital setting: ±0.01% of maximum frequency or below -10 to +50°C (14 to 122°F)
accuracy - Analog setting: ±0.5% of base frequency or below 25 ±10°C (77±18°F)
PM-SVC
- Digital setting: ±0.5% of base frequency or below -10 to +50°C (14 to 122°F)
- V/f control VF
- Speed sensor less vector control (Dynamic torque vector control) IM-SVC(DTV)
- V/f control with slip compensation active VF with SC
Control method - V/f control with speed sensor (The PG option card is required.) IMPG-VF
- V/f Control with speed sensor (+Auto Torque Boost) (The PG option card is required.) IMPG-ATB
External Dimensions
- Vector control with speed sensor (The PG option card is required.) IMPG-VC
- Vector control without magnetic pole position sensor PM-SVC
- Possible to set output voltage at base frequency and at maximum output frequency (80 to 240 V).
Voltage/Frequency - Possible to set output voltage at base frequency and at maximum output frequency (160 to 500 V).
characteristic - Non-linear V/f setting (3 points): Free voltage (0 to 500 V) and frequency (0 to 500 Hz) can be set.
- Non-linear V/f setting (3 points): Free voltage (0 to 240 V) and frequency (0 to 500 Hz) can be set.
- Auto torque boost (For constant torque load)
Control

Torque boost - Manual torque boost: Torque boost value can be set between 0.0 and 20.0%.
- Select application load with the function code. (Variable torque load or constant torque load)

Three phase 400V class


- 200% or above (HHD spec.:type 0072 or below) / 150% or higher (HHD spec.:type 0085 or above) at reference
Options

frequency 0.5Hz
- 120% or higher at reference frequency 0.5Hz, (HND/ND spec.)
- 150% or higher at reference frequency 0.5Hz, (HD spec.)
(Base frequency 50 Hz, with activating the slip compensation and the auto torque boost mode, applied motor
Starting torque
is Fuji 4-pole standard motor.)
Three phase 200V class and single phase 200V class
- 200% or above (HHD spec.:type 0069 or below) at reference frequency 0.5Hz
- 120% or higher at reference frequency 0.5Hz, (HND spec.)
(Base frequency 50 Hz, with activating the slip compensation and the auto torque boost mode, applied motor
is Fuji 4-pole standard motor.)

13
*VTTVU:WLJPÄJH[PVUZ
Items :WLJPÄJH[PVUZ 9LTHYRZ
2L`WHK!
:[HY[HUKZ[VW^P[OHUKRL`Z:[HUKHYKRL`WHK

:[HY[HUKZ[VW^P[OHUKRL`Z6W[PVUT\S[PM\UJ[PVUHSRL`WHK
:[HY[:[VWVWLYH[PVU
 ,_[LYUHS ZPNUHSZ KPNP[HS PUW\[Z! -VY^HYK 9L]LYZL YV[H[PVU Z[VW JVTTHUK JHWHISL VM ^PYL VWLYH[PVU
JVHZ[[VZ[VWJVTTHUKL_[LYUHSHSHYTHSHYTYLZL[L[J
3PURVWLYH[PVU!6WLYH[PVU]PHI\PS[PU9:VYÄLSKI\ZVW[PVUJVTT\UPJH[PVUZ
:^P[JOPUNVWLYH[PVUJVTTHUK!9LTV[LSVJHSZ^P[JOPUNSPURZ^P[JOPUN

2L`WHK!:L[[HISL^P[OHUKRL`Z
(UHSVNPUW\[
,_[LYUHS]VS\TL!(]HPSHISL[VILZL[^P[OL_[LYUHSMYLX\LUJ`JVTTHUKWV[LU[PVTL[LY[VR£> between
(UHSVNPUW\[![V—=+*—=+*[V— [LYTPUHSBD +*[V=
 [V=+*=+*[V [LYTPUHSBD PZH]HPSHISL
 [VT(+*[V [LYTPUHSB*D ^P[OHUHSVN
 [VT(+*[V[V [LYTPUHSB*D IPHZNHPU
 [VT(+*[V [LYTPUHSB*D M\UJ[PVUMVY
 [VT(+*[V[V [LYTPUHSB*D PUW\[
 [V=+*=+*[V [LYTPUHSB=D
 [V=+*=+*[V[V [LYTPUHSB=D
<7+6>5VWLYH[PVU!-YLX\LUJ`JHUILPUJYLHZLKVYKLJYLHZLK^OPSL[OLKPNP[HSPUW\[ZPNUHSPZ65
4\S[PZ[LWMYLX\LUJ`!:LSLJ[HISLMYVTKPMMLYLU[MYLX\LUJPLZZ[LW[V
7H[[LYU6WLYH[PVU4VKL!(\[VTH[PJHSS`Y\UPUHJJVYKHUJL^P[O[OLWYL]PV\ZS`JVUÄN\YLKY\UUPUN[PTLYV[H[PVU
KPYLJ[PVUHJJLSLYH[PVUKLJLSLYH[PVUHUKYLMLYLUJLMYLX\LUJ`4H_PT\THSSV^HISLZL[[PUNZHYLZ[HNLZ
3PURVWLYH[PVU!*HUILZWLJPÄLK]PHI\PS[PU9:VYI\PS[PU*(56WLUJVTT\UPJH[VUZ:[HUKHYK
   *HUILZWLJPÄLK]PHI\ZJVTT\UPJH[VUZ6W[PVU
 :^P[JOPUN MYLX\LUJ` ZL[[PUN ZV\YJL! ;^V VM MYLX\LUJ` ZL[[PUNZ ZV\YJL JHU IL Z^P[JOLK ^P[O HU L_[LYUHS
ZPNUHSKPNP[HSPUW\[
-YLX\LUJ`ZL[[PUN   9LTV[LSVJHSZ^P[JOPUN
  3PURZ^P[JOPUN
(\_PSPHY`MYLX\LUJ`ZL[[PUN!0UW\[ZH[[LYTPUHSZBDB*DVYB=DJHUILHKKLK[V[OLTHPUZL[[PUNHZH\_PSPHY`
MYLX\LUJ`ZL[[PUNZ
- 6WLYH[PVUH[HZWLJPÄLKYH[PV!;OLYH[PVJHUILZL[I`HUHSVNPUW\[ZPNUHS+*=T( ]HYPHISL
0U]LYZLVWLYH[PVU!:^P[JOHISLMYVT [V=+*[V [V [V=+*[V
Control

   I`L_[LYUHSJVTTHUK[LYTPUHSZBDB=D
   !:^P[JOHISLMYVT [V=+*[V [V [V=+*[V
   I`L_[LYUHSJVTTHUK[LYTPUHSBD
   !:^P[JOHISLMYVT [VT(+*[V [V [VT(+*[V
   I`L_[LYUHSJVTTHUK[LYTPUHSB*D
   !:^P[JOHISLMYVT [VT(+*[V [V [VT(+*[V
   I`L_[LYUHSJVTTHUK[LYTPUHSB*D
7\SZL[YHPUPUW\[Z[HUKHYK!
  7\SZLPUW\[$;LYTPUHSB?D9V[H[PVUHSKPYLJ[PVU$(UV[OLYPUW\[[LYTPUHSL_JLW[B?D
  *VTWSLTLU[HY`V\[W\[!4H_R/a6WLUJVSSLJ[VYV\[W\[!4H_R/a
7\SZL[YHPUPUW\[VW[PVU!;OL7.VW[PVUJHYKPZYLX\PYLK
  *>**>W\SZLW\SZLYV[H[PVUHSKPYLJ[PVU
  *VTWSLTLU[HY`V\[W\[!4H_R/a6WLUJVSSLJ[VYV\[W\[!4H_R/a
:L[[PUNYHUNL!-YVT[VZ
 :^P[JOPUN! ;OL MV\Y [`WLZ VM HJJLSLYH[PVUKLJLSLYH[PVU [PTL JHU IL ZL[ VY ZLSLJ[LK PUKP]PK\HSS` Z^P[JOHISL
K\YPUNVWLYH[PVU
(JJLSLYH[PVUKLJLSLYH[PVUWH[[LYU!3PULHYHJJLSLYH[PVUKLJLSLYH[PVU:ZOHWLHJJLSLYH[PVUKLJLSLYH[PVU^LHR
(JJLSLYH[PVU
MYLLZL[I`M\UJ[PVUJVKLZJ\Y]PSPULHYHJJLSLYH[PVUKLJLSLYH[PVU
+LJLSLYH[PVU[PTL
+LJLSLYH[PVUTVKLJVHZ[[VZ[VW!:O\[VMMVM[OLY\UJVTTHUKTHRLZ[OLTV[VYJVHZ[[VHZ[VW
(**+,*[PTLMVY 1VNNPUNVWLYH[PVU JHUILZL[[VZ
+LJLSLYH[PVU[PTLMVYMVYJPISLZ[VW!+LJLSLYH[PVUZ[VWI`[OLMVYJPISLZ[VW:;67
   :J\Y]L^PSSILJHUJLSLKK\YPUN -VYJL[V:[VW 
-YLX\LUJ`SPTP[LY :WLJPÄLZ[OL\WWLYHUKSV^LYSPTP[ZPU/a
<WWLYSPTP[HUKSV^LY :LSLJ[HISLMVY[OLVWLYH[PVUWLYMVYTLK^OLU[OLYLMLYLUJLMYLX\LUJ`KYVWZILSV^[OLSV^LYSPTP[ZWLJPÄLKI`
SPTP[MYLX\LUJPLZ YLSH[LKM\UJ[PVUJVKL
)PHZMVYMYLX\LUJ`
)PHZVMZL[MYLX\LUJ`HUK70+JVTTHUKJHUILPUKLWLUKLU[S`ZL[ZL[[PUNYHUNL![V— 
70+JVTTHUK
.HPU!:L[PU[OLYHUNLMYVT[V
6MMZL[!:L[PU[OLYHUNLMYVT[V
(UHSVNPUW\[
-PS[LY!:L[PU[OLYHUNLMYVTZ[VZ
7VSHYP[`!:LSLJ[MYVT—VY
1\TWMYLX\LUJ` ;OYLLVWLYH[PVUWVPU[ZHUK[OLPYJVTTVUQ\TW^PK[O[V/aJHUILZL[
;PTLYVWLYH[PVU 6WLYH[LHUKZ[VWI`[OL[PTLZL[^P[ORL`WHKJ`JSLVWLYH[PVU
6WLYH[PVU^P[ORL`Z[HUKHYKRL`WHKVYRL`T\S[PM\UJ[PVUHSRL`WHKVYKPNP[HSJVU[HJ[PUW\[
1VNNPUNVWLYH[PVU
->+VY9,=,_JS\ZP]LHJJLSLYH[PVUKLJLSLYH[PVU[PTLZL[[PUNL_JS\ZP]LMYLX\LUJ`ZL[[PUN

14
F U J I E L E C T R I C I N V E RT E R S

*VTTVU:WLJPÄJH[PVUZ

Major Functions
Items :WLJPÄJH[PVUZ 9LTHYRZ
(\[VYLZ[HY[HM[LY
TVTLU[HY`WV^LY
MHPS\YL
;YPWH[WV^LYMHPS\YL ;OLPU]LY[LY[YPWZPTTLKPH[LS`HM[LYWV^LYMHPS\YL
;YPWH[WV^LYYLJV]LY` *VHZ[[VZ[VWH[WV^LYMHPS\YLHUK[YPWH[WV^LYYLJV]LY`
+LJLSLYH[PVUZ[VW +LJLSLYH[PVUZ[VWH[WV^LYMHPS\YLHUK[YPWHM[LYZ[VWWHNL

6WDQGDUG0RGHO6SHFLðFDWLRQV
*VU[PU\L[VY\U 6WLYH[PVUPZJVU[PU\LK\ZPUN[OLSVHKPULY[PHLULYN`
:[HY[H[[OLMYLX\LUJ`ZLSLJ[LK *VHZ[[VZ[VWH[WV^LY
ILMVYLTVTLU[HY`WV^LYMHPS\YL MHPS\YLHUKZ[HY[HM[LYWV^LYYLJV]LY`H[[OLMYLX\LUJ`ZLSLJ[LKILMVYLTVTLU[HY`Z[VW
*VHZ[[VZ[VWH[WV^LYMHPS\YLHUKZ[HY[H[[OLZ[HY[PUN
:[HY[H[Z[HY[PUNMYLX\LUJ`
MYLX\LUJ`HM[LYWV^LYYLJV]LY`
*VHZ[[VZ[VWH[WV^LYMHPS\YLHUKZ[HY[H[[OLZLYJOLK
:[HY[H[[OLZLHYJOLKMYLX\LUJ`
MYLX\LUJ`HM[LYWV^LYYLJV]LY`
3PTP[Z[OLJ\YYLU[I`OHYK^HYL[VWYL]LU[HUV]LYJ\YYLU[[YPWJH\ZLKI`MHZ[SVHK]HYPH[PVUVYTVTLU[HY`WV^LY
/HYK^HYLJ\YYLU[SPTP[LY
MHPS\YL^OPJOJHUUV[ILJV]LYLKI`[OLZVM[^HYLJ\YYLU[SPTP[LY;OPZSPTP[LYJHUILJHUJLSLK
:VM[^HYLJ\YYLU[SPTP[LY (\[VTH[PJHSS`YLK\JLZ[OLMYLX\LUJ`ZV[OH[[OLV\[W\[J\YYLU[ILJVTLZSV^LY[OHU[OLWYLZL[VWLYH[PVUSL]LS

&RPPRQ6SHFLðFDWLRQV
6WLYH[PVUI`JVTTLYJPHS
WV^LYZ\WWS` >P[OJVTTLYJPHSWV^LYZLSLJ[PVUJVTTHUK[OLPU]LY[LYV\[W\[Z/a:>:>

*VTWLUZH[LZ[OLTV[VYZSPWPUVYKLY[VRLLW[OLPYZWLLKH[[OLYLMLYLUJLVULYLNHYKSLZZVM[OLPYSVHK[VYX\L
:SPWJVTWLUZH[PVU
(KQ\Z[HISLJVTWLUZH[PVU[PTLJVUZ[HU[PZWVZZPISL
 0U H THJOPUL KYP]LU ^P[O T\S[PTV[VY Z`Z[LT [OPZ M\UJ[PVU HKQ\Z[Z [OL ZWLLK VM LHJO TV[VY PUKP]PK\HSS` [V
+YVVWJVU[YVS
IHSHUJL[OLPYSVHK[VYX\L
*VU[YVSV\[W\[[VYX\LVY[VYX\LJ\YYLU[ZV[OH[V\[W\[[VYX\LVY[VYX\LJ\YYLU[HYLWYLZL[SPTP[PUN]HS\LVYSLZZ
;VYX\LSPTP[LY ;OL[VYX\LJ\YYLU[SPTP[PZVUS`H]HPSHISLPU047.=*VY74:=*TVKL
:^P[JOHISLIL[^LLUZ[HUKUK[VYX\LSPTP[]HS\LZ

Basic Wiring Diagram


 ;VYX\LSPTP[ HUK ;VYX\LJ\YYLU[SPTP[ HYLZLSLJ[HISL 047.=*
;VYX\LJ\YYLU[SPTP[LY
 ;VYX\LSPTP[ VY ;VYX\LJ\YYLU[SPTP[ I`HUHSVNPUW\[ 74:=*
>OLUKL[LJ[LK[VYX\LVYJ\YYLU[L_JLLK[OLWYLZL[]HS\LPU]LY[LY^PSSKLJLSLYH[LHUKZ[VWVY^PSSJVHZ[[VZ[VW
6]LYSVHKZ[VWWPUN
HTV[VY
70+WYVJLZZVYMVYWYVJLZZJVU[YVSKHUJLYJVU[YVS
5VYTHSVWLYH[PVUPU]LYZLVWLYH[PVU
 70+ JVTTHUK! 2L`WHK HUHSVN PUW\[ MYVT [LYTPUHSZ BD B*DHUK B=D 4\S[PZ[LW ZL[[PUN:LSLJ[HISL MYVT 
WVPU[Z9:JVTT\UPJH[PVU
70+MLLKIHJR]HS\LMYVT[LYTPUHSZBDB*DHUKB=D
Control

70+*VU[YVS
(SHYTV\[W\[HIZVS\[L]HS\LHSHYTKL]PH[PVUHSHYT
3V^SPX\PKSL]LSZ[VWM\UJ[PVU

Terminal Functions
(U[PYLZL[^PUK\WM\UJ[PVU
70+V\[W\[SPTP[LY
0U[LNYH[PVUYLZL[OVSK
 ;OL H\[VYLZL[ M\UJ[PVU [OH[ THRLZ [OL PU]LY[LY H\[VTH[PJHSS` H[[LTW[ [V YLZL[ [OL [YPWWLK Z[H[L HUK YLZ[HY[
(\[VYLZL[ ^P[OV\[PZZ\PUNHUHSHYTV\[W\[MVYHU`HSHYTL]LUPMHU`WYV[LJ[P]LM\UJ[PVUZ\IQLJ[[VYLZL[PZHJ[P]H[LK
;OLHSSV^HISLTH_PT\TU\TILYVMYLZL[[PTLZMVY[OLPU]LY[LY[VH\[VTH[PJHSS`H[[LTW[[VLZJHWL[OL[YPWWLK
Z[H[LPZ
(\[VZLHYJOMVYPKSPUN  ;OL PU]LY[LY H\[VTH[PJHSS` ZLHYJOLZ MVY [OL PKSPUN TV[VY ZWLLK [V Z[HY[ [V KYP]L ^P[OV\[ Z[VWWPUN 4V[VY
TV[VYZWLLK JVUZ[HU[ZT\Z[ILULLKLK[\UPUN!(\[V[\UPUNVMÅPUL

External Dimensions
0M[OL+*SPURI\Z]VS[HNLVYJHSJ\SH[LK[VYX\LL_JLLKZ[OLH\[VTH[PJKLJLSLYH[PVUSL]LS
K\YPUNKLJLSLYH[PVU[OLPU]LY[LYH\[VTH[PJHSS`WYVSVUNZ[OLKLJLSLYH[PVU[PTL[VH]VPK
V]LY]VS[HNL [YPW 0[ PZ WVZZPISL [V ZLSLJ[ MVYJPISL KLJLSLYH[PVU HJ[\H[LK ^OLU [OL KLJLSLYH[PVU [PTL ILJVTLZ
(\[VTH[PJKLJLSLYH[PVU
[OYLL[PTLZSVUNLY
 0M [OL JHSJ\SH[LK [VYX\L L_JLLKZ H\[VTH[PJ KLJLSLYH[PVU SL]LS K\YPUN JVUZ[HU[ ZWLLK VWLYH[PVU [OL PU]LY[LY
H]VPKZV]LY]VS[HNL[YPWI`PUJYLHZPUN[OLMYLX\LUJ`
+LJLSLYH[PVUJOHYHJ[LYPZ[PJ  ;OL TV[VY SVZZ PZ PUJYLHZLK K\YPUN KLJLSLYH[PVU [V YLK\JL [OL YLNLULYH[P]L LULYN` PU [OL PU]LY[LY [V H]VPK
PTWYV]LKIYHRPUNJHWHJP[` V]LY]VS[HNL[YPW
(\[VLULYN`ZH]PUN ;OLV\[W\[]VS[HNLPZJVU[YVSSLK[VTPUPTPaL[OL[V[HSWV^LYSVZZVM[OLTV[VYHUK[OLPU]LY[LYH[HJVUZ[HU[
VWLYH[PVU ZWLLK
6]LYSVHKWYL]LU[PVU  0M [OL HTIPLU[ [LTWLYH[\YL VY PU[LYUHS 0.); Q\UJ[PVU [LTWLYH[\YL PZ HSTVZ[ ULHY [OL V]LYOLH[ SL]LS K\L [V
control V]LYSVHK[OLPU]LY[LYKYVWZP[ZV\[W\[MYLX\LUJ`H\[VTH[PJHSS`PUVYKLY[VLZJHWLV]LYSVHKZP[\H[PVU
Options

*HUJLSZ [OL \UKLY]VS[HNL WYV[LJ[PVU ZV [OH[ [OL PU]LY[LY \UKLY HU \UKLY]VS[HNL JVUKP[PVU Y\UZ [OL TV[VY ^P[O
)H[[LY`<7:VWLYH[PVU
IH[[LY`<7:WV^LY
4LHZ\YLZ[OLTV[VYWHYHTL[LYZ^OPSL[OLTV[VYPZZ[VWWLKVYY\UUPUNMVYZL[[PUN\WTV[VYWHYHTL[LYZ
(\[V[\UPUNVMMSPUL ;\UPUNTVKL[VVUS`PKLU[PM` 9HUK ?
;\UPUNTVKL[VPKLU[PM`[OLWHYHTL[LYZMVY74TV[VY
 (\[VTH[PJHSS` HKQ\Z[Z TV[VY WHYHTL[LYZ ^OPSL [OL TV[VY PZ KYP]PUN PU VYKLY [V WYL]LU[ [OL TV[VY ZWLLK
(\[V[\UPUNVUSPUL
Å\J[\H[PVUJH\ZLKI`[OL[LTWLYH[\YLYPZLVM[OLTV[VY
*VVSPUNMHU656-- +L[LJ[ZPU]LY[LYPU[LYUHS[LTWLYH[\YLHUKZ[VWZJVVSPUNMHU^OLU[OL[LTWLYH[\YLPZSV^
control [OLMHUJVU[YVSZPNUHSJHUILV\[W\[[VHUL_[LYUHSKL]PJL
:^P[JOHISLHTVUN[OL[^VTV[VYZ
Z[[VUKTV[VY
0[PZWVZZPISL[VZL[[OLIHZLMYLX\LUJ`YH[LKJ\YYLU[[VYX\LIVVZ[HUKLSLJ[YVUPJ[OLYTHSZSPWJVTWLUZH[PVUHZ
ZL[[PUNZ
[OLKH[HMVYZ[[VUKTV[VYZ

15
*VTTVU:WLJPÄJH[PVUZ
Items :WLJPÄJH[PVUZ Remarks
The status of external digital signal connected with the universal digital input terminal is transferred to the host
Universal DI
controller.
Universal DO Digital command signal from the host controller is output to the universal digital output terminal.
Universal AO The analog command signal from the host controller is output to the analog output terminal.
5V[JOÄS[LYMVY]PIYH[PVUJVU[YVS-VY047.=*
IMPG-VC
Speed control - Selectable among the four set of the auto speed regulator (ASR) parameters.
PM-SVC
;OL7.VW[PVUJHYKPZYLX\PYLK
In a machine such as winder/unwinder, regulates the motor speed to keep the peripheral speed of the roll
Line speed control constant. IMPG-VF
;OL7.VW[PVUJHYKPZYLX\PYLK
The positioning control starts from the preset start point and counts the feedback pulses from PG inside the Excluded
Positioning control with
inverter. The motor can be automatically started decelerating to the cleep speed which can be detected the IMPG-VC
pulse counter
[HYNL[WVZP[PVUZV[OH[[OLTV[VYJHUZ[VWULHY[OLWVZP[PVU;OL7.VW[PVUJHYKPZYLX\PYLK PM-SVC
Master-follower ,UHISLZ Z`UJOYVUV\Z VWLYH[PVU VM [^V TV[VYZ LX\PWWLK ^P[O H W\SZL NLULYH[VY7.;OL 7. VW[PVU JHYK PZ
operation YLX\PYLK
Pre-excitation ,_JP[H[PVUPZJHYYPLKV\[[VJYLH[L[OLTV[VYÅ\_ILMVYLZ[HY[PUN[OLTV[VY;OL7.VW[PVUJHYKPZYLX\PYLK IMPG-VC
Zero speed control ;OLTV[VYZWLLKPZOLSK[VaLYVI`MVYJPIS`aLYVPUN[OLZWLLKJVTTHUK;OL7.VW[PVUJHYKPZYLX\PYLK IMPG-VC
Servo lock :[VWZ[OLTV[VYHUKOVSKZ[OLTV[VYPU[OLZ[VWWLKWVZP[PVU;OL7.VW[PVUJHYKPZYLX\PYLK IMPG-VC
When the run command turns OFF and the motor speed fall below the preset DC braking starting speed, the
DC braking inverter starts to inject DC current into the motor in order to stop the motor.
When the run command turns ON,the inverter starts to inject DC current into the motor in order to pre-excite.
- The inverter can output the signal which ON/OFF timing adjusted so that the mechanical brake can be turned in
Mechanical brake Excluded
JVUQ\UJ[PVU^P[OKL[LJ[LKJ\YYLU[[VYX\LMYLX\LUJ`HUKYLSLHZLHWWS`KLSH`[PTLYZ
control PM-SVC
Control

- Mechanical brake interlock input


(UHSVN[VYX\L[VYX\LJ\YYLU[JVTTHUKPUW\[
- Speed limit function is provided to prevent the motor from becoming out of control.
;VYX\LJVU[YVS IMPG-VC
;VYX\LIPHZHUHSVNZL[[PUNKPNP[HSZL[[PUN
;OL7.VW[PVUJHYKPZYLX\PYLK
Rotational direction
- Select either of reverse or forward rotation prevention.
control

The digital logic circuits and an analog arithmetic circuits can be chosen and connected with digital/analog
input/output signals.
;OLZPTWSLYLSH`ZLX\LUJL^OPJO[OLJ\Z[VTLYZKLTHUKZJHUILJVUZ[P[\[LKHUKTHKL[VJHSJ\SH[L
- Logic circuit
+PNP[HS(5+69?69ÅPWÅVWZYPZPUNMHSSPUNLKNLKL[LJ[PVUJV\U[LYZL[J
(Analog) Addition, subtraction, multiplication, division, limitter, absolute value, sign inversion addition,
Customizable logic comparison, highest selection, lowest selection, average value, measure conversion.
interface - Multifunctional timer
On-delay, off-delay, pulse train, etc.
Setting range: 0.0 to 600 s
- Input/output signal
terminal input / output, inverter control function
- Others
The 200 steps are available. Each step has 2 inputs and 1 output.

Applicable functions for


- Wire drawing machine
- Hoist ;OLZWLJPÄJM\UJ[PVUZ^OPJOPZZ\P[HISLMVYLHJOHWWSPJH[PVUÄLSKHYLYLHSPaLKI`J\Z[VTPaHISLSVNPJZ
- Spinning machine
(Traverse)
Detachable, 7 segments LEDs (4 digits) , 7 keys(PRG/RESET,FUNC/DATA,UP,DOWN, RUN,STOP,SHIFT) and
Display
6LED indicator (KEYPAD CONTROL,Hz,A,kW,×10,RUN)

:WLLK TVUP[VY YLMLYLUJL MYLX\LUJ` V\[W\[ MYLX\LUJ` TV[VY ZWLLK SVHK ZOHM[ ZWLLK SPUL ZWLLK HUK ZWLLK
PUKPJH[PVU^P[OWLYJLU[6\[W\[J\YYLU[PU94:B(D6\[W\[]VS[HNLPU94:B=D*HSJ\SH[LK[VYX\LB D0UW\[WV^LY
Running/Stopping BR>D 70+ JVTTHUK ]HS\L 70+ MLLKIHJR ]HS\L 70+ V\[W\[ ;PTLY ;PTLY VWLYH[PVUBZD 3VHK MHJ[VY B D 4V[VY
Indicate

V\[W\[BR>D;VYX\LJ\YYLU[B D4HNUL[PJÅ\_JVTTHUKB D(UHSVNPUW\[B D0UW\[^H[[OV\YBR>OD


Constant feeding rate time (set value) [min], Constant feeding rate time (running) [s]
- The life early warning of the main circuit capacitors, capacitors on the PCBs and the cooling fan can be displayed.
- An external output is issued in a transistor output signal.
Life early warning - Outputs the warning when the maintenance time or the number of start times has exceeded the preset.
(TIPLU[[LTWLYH[\YL!͵‡-
3VHKMHJ[VY!0U]LY[LYYH[LKJ\YYLU[ //+ZWLJ /5+/+5+ZWLJ

16
F U J I E L E C T R I C I N V E RT E R S

*VTTVU:WLJPÄJH[PVUZ

Major Functions
Items :WLJPÄJH[PVUZ Remarks

- Displays DC link bus voltage, Max. Output current in RMS, Input watt-hour, Input watt-hour data, Temperature
(inside the inverter and heat sink, Maximum value of each one), Capacitance of the DC link bus capacitor,
Lifetime of DC link bus capacitor (elapsed hours and remaining hours), Cumulative run time of power-ON time
counter of the inverter, electrolytic capacitors on the printed circuit boards, cooling fan and each motor,
Maintenance monitor
Remaining time before the next motor maintenance, Remaining startup times before the next maintenance,
Number of startups (of each motor), Light alarm factors (Latest to 3rd last), Contents and numbers of RS-485
Indicate

communications errors, Option error factors , Number of option errors ,ROM version of Inverter, Keypad and

6WDQGDUG0RGHO6SHFLðFDWLRQV
Option port.

I/O checking Shows the status of the terminal Digital input/output, Relay out, Analog input/output.
Locked by password Limits to change or display in function code .
Trip mode Displays the cause of trip by codes.
Light-alarm Shows the light-alarm display 7-segment.
- Trip history: Saves and displays the cause of the last four trips (with a code).
Running or trip mode
- Saves and displays the detailed operation status data of the last four trips.
Installation location Indoors
Standard (Open Type)

&RPPRQ6SHFLðFDWLRQV
[V‡*//+/5+ZWLJ
[V‡*/+5+ZWLJ
Ambient
NEMA/UL Type 1
[V‡*//+/5+ZWLJ
[V‡*/+5+ZWLJ
Ambient humidity [V  9/^P[OV\[JVUKLUZH[PVU
:OHSS IL MYLL MYVT JVYYVZP]L NHZLZ ÅHTTHISL NHZLZ VPS TPZ[ K\Z[Z ]HWVY ^H[LY KYVWZ HUK KPYLJ[ Z\USPNO[
Atmosphere (Pollution degree 2 (IEC60664-1))
The atmosphere must contain only a low level of salt. (0.01 mg/cm 2 or less per year)

Basic Wiring Diagram


1000m or lower
If the inverter is used in an altitude above 1000 m, you should apply an output current derating factor as listed in
below table.
Operating environment

Altitude Output current derating factor


1000m or lower 1.00
Altitude
1000 to 1500m 0.97
1500 to 2000m 0.95
2000 to 2500m 0.91
2500 to 3000m 0.88

Terminal Functions
Three phase 400V class series TYPE:0203 or below TYPE:0240 or above
2 to less than 9Hz 3mm:(Max. amplitude) 3mm:(Max. amplitude)
9 to less than 20Hz 9.8m/s 2 2m/s 2
20 to less than 55Hz 2m/s 2 2m/s 2
55 to less than 200Hz 1m/s 2 1m/s 2
Vibration
Three phase 200V class series TYPE:0069 or below
2 to less than 9Hz 3mm:(Max. amplitude)
9 to less than 20Hz 9.8m/s 2
20 to less than 55Hz 2m/s 2 External Dimensions
55 to less than 200Hz 1m/s 2

[V‡*PU[YHUZWVY[
Storage environment

Temperature Avoid such places where the inverter will be subjected to sudden changes in
[V‡*PUZ[VYHNL
temperature that will cause condensation to form.
Relative humidity [V  9/
;OLPU]LY[LYT\Z[UV[ILL_WVZLK[VK\Z[KPYLJ[Z\USPNO[JVYYVZP]LVYÅHTTHISLNHZLZVPSTPZ[]HWVY^H[LY
Atmosphere
drops or vibration. The atmosphere must contain only a low level of salt. (0.01 mg/cm 2 or less per year)
Atmospheric 86 to 106kPa (during storage)
pressure 70 to 106kPa (during transportation)
*Note : The meaning of the described abbreviations are shown as follows.
Options

VF V/f control
 04:=*+;= :WLLKZLUZVYSLZZ]LJ[VYJVU[YVS+`UHTPJ[VYX\L]LJ[VYJVU[YVS
VF with SC V/f control with slip compensation
 047.=- =MJVU[YVS^P[OZWLLKZLUZVY;OL7.VW[PVUJHYKPZYLX\PYLK
 047.(;) =MJVU[YVS^P[OZWLLKZLUZVY(\[V;VYX\L)VVZ[;OL7.VW[PVUJHYKPZYLX\PYLK
 047.=* =LJ[VYJVU[YVS^P[OZWLLKZLUZVY;OL7.VW[PVUJHYKPZYLX\PYLK
PM-SVC Magnetic pole position sensorless vector control

17
Basic Wiring Diagram
With built-in CAN communication port and Single analog output
FRN E2 - E
GA

In case of the motor with built-in cooling fan

Transformer
Thermal relay DBR (Option)
FU 2
FV (CM)
FM 1
FW (G) P DB

P(+) DB 2
R 1
DBR (Option) P(+) N(-)
(THR)
(G)
(G) Braking unit BU
2 (option)
(CM)
1
DCR (option) (*1) P DB (THR) P(+) N(-)
MCCB
or P1 P(+) DB N(-)
RCD/ELCB MC Thermal relay Motor
Power supply
400V series L1/R
F U U
380V to 480V L2/S V V M
200V series R C
L3/T W W 3~
200V to 240V
50/60Hz PTC
· Power voltage switching connector Thermistor
R0 "CN UX" to [C1] TH1
Auxiliary control power supply T0 THC
· Fan power connector to [11]
"CN R" / "CN W"
E
R1 U2 U1 FAN NC
Auxiliary fan power supply T1 DC/DC
Charge lamp
G CN UX CN R CN W G Ground terminal
Ground terminal

30C
RJ45 connector
+24VDC 0V 30B Alarm output
Contact outputs
(for any fault)
30 30A

Keypad SW2
(EN1)
Enable input (Standard) Option connector
Communication port 1
(EN2) (RS-485)

(PLC) *2
SINK Removable terminal block
(PLC)
SW1
<Y2>
Motor overload early warnig
SOURCE
<Y1> Transistor output
Inverter running
Run forward command (FWD)
Common terminal for
<CMY>
Run reverse command (REV) transistor outputs
(SINK/SOURCE)

Select multi-frequency(0 to 1 step) (X1)

Digital input Select multi-frequency(0 to 3 step) (X2) Current output FMI


(4 (0) to 20 mADC)
Select multi-frequency(0 to 7 step) (X3) Voltage output FMV [FM]
(0 to +10 VDC) Output frequency 1 Analog / pulse output
Coast to a stop (X4) Pulse output FMP
(25 to 32 kp/s) SW5
Reset alarm (X5)
Common terminal for (CM) [11]
digital inputs 0V Analog output common
+10VDC
3
Potentiometer power supply [13]
Voltage input 12 DX+
(0 to +10 VDC) DX- Communication port2
Voltage input for setting 2 (0 to ±10 VDC) CAN+ (RS-485)
0 to +10VDC (0 to ±10VDC) [12]
0V CAN- (CAN-BUS) *3
SW6
Common terminal for 1 RJ45 connector
analog inputs [11] AI PTC
SW4
Analog input Current input C1
(4 (0) to 20 mADC) V2
[C1] PTC thermistor input
(+)
Voltage input V2 C1 SW6
Current/voltage input for setting (0 to +10 VDC)
+4(0) to 20mADC / 0 to +10VDC SW3
(-)
0V

DBR: Dynamic Braking Resister *1 When connecting an optional DC reactor (DCR), remove the jumper bar from the terminals P1 and P(+).
DCR: DC reactor The type 0139 (ND spec), 0168 (HD spec.) and higher types than 0203 are sure to connect the DCR (400V only).
RCD: Residual-current-operated protective device Use a DCR when the capacity of the power supply transformer exceeds 500 kVA and is 10 times or more the
ELCB: Earth leakage circuit breaker inverter rated capacity, or when there are thyristor-driven loads in the same power supply line.
MC: Magnetic contactor *2 The default setting is “Source logic” for EU model.
MCCB: Molded case circuit braker *3 America model is none conect

This wiring diagram is to be used as a reference only when using standard terminal block model.
NOTE When wiring your inverter and/or before applying power, please always follow the connection diagrams
and the relevant information written in the User's Manual.

18
F U J I E L E C T R I C I N V E RT E R S

Basic Wiring Diagram

Major Functions
Without built-in CAN communication port and with dual Analog outputs
FRN E2S- GB
K

6WDQGDUG0RGHO6SHFLðFDWLRQV
In case of the motor with built-in cooling fan

Transformer
Thermal relay DBR (Option)
FU 2
FV (CM)
FM 1
FW (G) P DB

P(+) DB 2
R 1
DBR (Option) P(+) N(-)
(THR)
(G)
(G) Braking unit BU
2 (option)
(CM)
1
DCR (option) (*1) P DB (THR) P(+) N(-)
MCCB
or P1 P(+) DB N(-)

&RPPRQ6SHFLðFDWLRQV
RCD/ELCB MC Thermal relay Motor
Power supply
400V series L1/R
F U U
380V to 480V L2/S V V M
200V series R C
L3/T W W 3~
200V to 240V
50/60Hz PTC
· Power voltage switching connector Thermistor
R0 "CN UX" to [C1] TH1
Auxiliary control power supply T0 THC
· Fan power connector to [11]
"CN R" / "CN W"
E
R1 U2 U1 FAN NC
Auxiliary fan power supply T1 DC/DC
Charge lamp
G CN UX CN R CN W G Ground terminal
Ground terminal

30C

Basic Wiring Diagram


RJ45 connector
+24VDC 0V 30B Alarm output
Contact outputs
(for any fault)
30 30A

Keypad SW2
(EN1)

Option connector
Enable input (Standard)
Communication port 1
(EN2) (RS-485)

(PLC) *2
SINK Removable terminal block
(PLC)
SW1

Terminal Functions
<Y2>
Motor overload early warnig
SOURCE
<Y1> Transistor output
Inverter running
Run forward command (FWD)
Common terminal for
<CMY>
Run reverse command (REV) transistor outputs
(SINK/SOURCE)

(X1) Current output FMI


Select multi-frequency(0 to 1 step) (4 (0) to 20 mADC)
(X2) Voltage output FMV [FM]
Digital input Select multi-frequency(0 to 3 step) (0 to +10 VDC) Output frequency 1
(X3) Pulse output FMP
Select multi-frequency(0 to 7 step) (25 to 32 kp/s) SW5
Coast to a stop (X4)

External Dimensions
(X5) [11]
Reset alarm 0V Analog output common
Common terminal for (CM)
digital inputs Analog / pulse output
Current output FMI
+10VDC (4 (0) to 20 mADC)
3 [FM2]
Potentiometer power supply [13] Output current
Voltage input 12
(0 to +10 VDC) Voltage output FMV
Voltage input for setting 2 (0 to ±10 VDC) (0~ +10VDC)
0 to +10VDC (0 to ±10VDC) [12] SW7
0V (*12)
Common terminal for 1 [11]
analog inputs [11] AI PTC 0V Analog output common
SW4
Analog input Current input C1 (*9)
(4 (0) to 20 mADC) V2
(DX+) Communication
[C1] PTC thermistor input
(+) (DX-) port2
Voltage input V2 C1 (RS-485)
Current/voltage input for setting (0 to +10 VDC)
+4(0) to 20mADC / 0 to +10VDC SW3
(5D)
(-) (SW6)
0V (*12)
Options

DBR: Dynamic Braking Resister *1 When connecting an optional DC reactor (DCR), remove the jumper bar from the terminals P1 and P(+).
DCR: DC reactor Use a DCR when the capacity of the power supply transformer exceeds 500 kVA and is 10 times or more the
RCD: Residual-current-operated protective device inverter rated capacity, or when there are thyristor-driven loads in the same power supply line.
ELCB: Earth leakage circuit breaker
MC: Magnetic contactor
MCCB: Molded case circuit braker

This wiring diagram is to be used as a reference only when using standard terminal block model.
NOTE When wiring your inverter and/or before applying power, please always follow the connection diagrams
and the relevant information written in the User's Manual.

19
Terminal Functions
Categoly

Symbol Name Functions Remarks

L1/R, L2/S,L3/T Connect the three-phase input power lines.


Main circuit power inputs
L1/L, L2/N Connect the single-phase input power lines.
R0, T0 Auxiliary power input for the For a backup of the control circuit power supply, connect AC power
Type 0059 or above (400V only)
control circuit lines same as that of the main power input.
Main circuit

R1, T1 Auxiliary power input for the Normally, no need to use these terminals.Use these terminals for an auxiliary power
Type 0203 or above (400V only)
cooling fans input of the fans in a power system using a power regenerative PWM converter.
U, V, W Inverter outputs Connect a three-phase motor.
P(+), P1 For DC reactor connection Connects a DC reactor.
P(+), N(-) For BRAKING UNIT connection/For DC bus Connects a braking resistor via the braking unit. Used for a DC bus connection system.
P(+), DB Type 0072 or below (400V series)
Braking resistor Connect an external braking resistor (option).
Type 0069 or below (200V series)
G Grounding for inverter Grounding terminals for the inverter.
Power supply (+10 VDC) for frequency command potentiometer
[13] Maximum supply rating : 10
Power supply for the potentiometer =HYPHISLYLZPZ[VY![VR£PZHWWSPJHISL
VDC, 10 mADC.
The potentiometer of 1/2 W rating or more should be connected.
Analog setting voltage input - External input voltage to be used as a below command. 0UW\[PTWLKHUJL!R£
0 to +10 VDC / 0 to 100% (0 to +5 VDC / 0 to 100%) Maximum input level : ±15 VDC
<Normal operation> 0 to ±10 VDC / 0 to ±100% (0 to ±5 VDC / 0 to ±100%) Input level is limited among
+10 to 0 to -10VDC / -100% to 0 to 100% -10 to 10 VDC regardless of
<Inverse operation> excessive input of ±10 VDC.
-10V to 0 to +10VDC / +100% to 0 to -100%
(Main frequency setting) -Use as the main frequency command set point. .HPU°![V
(PID control) -Use as PID command value or PID feedback signal. 6MMZL[°![V—
(Auxiliary frequency setting1,2) -Use as additional auxiliary setting to various frequency setting. Bias : ±100%
-By inputting analog signals from various sensors such as the temperature sensors in air Filter : 0.00 to 5.00s
[12] conditioners to the inverter, you can monitor the state of external devices via the communications
(Analog input monitor) SPUR)`\ZPUNHUHWWYVWYPH[LKPZWSH`JVLMÄJPLU[`V\JHUHSZVOH]L]HYPV\Z]HS\LZ[VILJVU]LY[LK
into physical quantities such as temperature and pressure before they are displayed.
-Use as gain for the frequency command.
(Gain setting)
-0% to 200% for 0 to 10 VDC
(Torque limit value) -Use as analog torque limit value
-Used as analog torque command value / Torque current command value.
(Torque command/Torque current command)
(The PG option card is required.)
(Torque bias amount) -Used as analog torque bias command value.(The PG option card is required.)
(Speed limit value) -Used as analog speed limit value of FWD/REV.(The PG option card is required.)
(C1) Analog setting voltage input - External input voltage to be used as a below command. 0UW\[PTWLKHUJL!£
4 to 20 mADC / 0 to 100%/ -100% to 0 to 100% (*1) Maximum input 30 mADC
<Normal operation> 0 to 20 mADC / 0 to 100%/ -100% to 0 to 100% (*1) Input level is limited up to 20
20 to 4 mADC / 0 to 100%/ -100% to 0 to 100% (*1) mADC regardless of excessive
<Inverse operation> input of 20 mADC.
20 to 0 mADC / 0 to 100%/ -100% to 0 to 100% (*1)
(Main frequency setting) -Use as the main frequency command set point. Gain: 0 to 200%
(PID control) -Use as PID command value or PID feedback signal. Offset: 0 to ±5%
(Auxiliary frequency setting1,2) -Use as additional auxiliary setting to various frequency setting. Bias: ±100%
-By inputting analog signals from various sensors such as the temperature sensors in air Filter: 0.00 to 5.00s
Analog inputs

conditioners to the inverter, you can monitor the state of external devices via the communications
(Analog input monitor) SPUR)`\ZPUNHUHWWYVWYPH[LKPZWSH`JVLMÄJPLU[`V\JHUHSZVOH]L]HYPV\Z]HS\LZ[VILJVU]LY[LK
into physical quantities such as temperature and pressure before they are displayed.
-Use as gain for the frequency command.
(Gain setting)
-0 to 200% for 4(0) to 20mADC
(Torque limit value) -Use as analog torque limit value
-Used as analog torque command value / Torque current command value.
(Torque command/Torque current command)
(The PG option card is required.)
(Torque bias amount) -Used as analog torque bias command value.(The PG option card is required.)
(Speed limit value) -Used as analog speed limit value of FWD/REV.(The PG option card is required.)
[C1] (V2) Analog setting voltage input - External input voltage to be used as a below command. 0UW\[PTWLKHUJL!R£
0 to +10 VDC/ 0 to 100% /-100 to 0 to 100% (0 to +5 VDC / 0 to 100%) Maximum input ±15 VDC
<Normal operation> 0 to +10 VDC/ 0 to ±100% /-100 to 0 to 100%(*1) (0 to ±5 VDC / 0 to ±100%) Input level is limited among
+10 to 0VDC/0 to 100%/-100% to 0 to 100% -10 to 10 VDC regardless of
<Inverse operation> excessive input of ±10 VDC.
+10 to 0 VDC / 0 to ±100% /-100 to 0 to 100%(*1) (+5 to 0 VDC/ 0 to ±100%)
(Main frequency setting) -Use as the main frequency command set point. Gain: 0 to 200%
(PID control) -Use as PID command value or PID feedback signal. Offset: 0 to ±5%
(Auxiliary frequency setting1,2) -Use as additional auxiliary setting to various frequency setting. Bias: ±100%
-By inputting analog signals from various sensors such as the temperature sensors in air Filter: 0.00 to 5.00s
conditioners to the inverter, you can monitor the state of external devices via the communications
(Analog input monitor) SPUR)`\ZPUNHUHWWYVWYPH[LKPZWSH`JVLMÄJPLU[`V\JHUHSZVOH]L]HYPV\Z]HS\LZ[VILJVU]LY[LK
into physical quantities such as temperature and pressure before they are displayed.
-Use as gain for the frequency command.
(Gain setting)
-0 to 200% for 0 to 10 VDC
(Torque limit value) -Used as analog torque limit value
-Used as analog torque command value / Torque current command value
(Torque command/Torque current command)
(The PG option card is required.)
(Torque bias amount) -Used as analog torque bias command value.(The PG option card is required.)
(Speed limit value) -Used as analog speed limit value of FWD/REV.(The PG option card is required.)
(PTC) (PTC thermistor) -PTC thermistor connection to protect the motor overheat.
[11] Common terminals for analog input signals [12], [13], [C1], and analog This terminal is electrically isolated
Analog common
output signals [FM]. from terminal [CM], [CMY].

20
F U J I E L E C T R I C I N V E RT E R S

Terminal Functions

Major Functions
Categoly

Symbol Name Functions Remarks

Analog monitor The output can be either analog DC voltage (0 to 10 VDC), analog
DC current (4(0) to 20 mADC) or pulse train (25 to 32000 p/s).
Any one item can be selected from the following items.

<Voltage output>(*3) 0 to +10 VDC / 0 to 100% (0 to +5 VDC / 0 to 100%)

6WDQGDUG0RGHO6SHFLðFDWLRQV
0UW\[PTWLKHUJLVM[OLL_[LYUHSKL]PJL!4PUR£H[[V=+*V\[W\[
(While the terminal is outputting 0 to 10 VDC, it is capable of driving up to
[^VHUHSVN]VS[TL[LYZ^P[OR£PTWLKHUJL
4 to 20 mADC / 0 to 100%
Analog outputs

<Current output>(*3) 0 to 20 mADC / 0 to 100%


[FM] 0UW\[PTWLKHUJLVM[OLL_[LYUHSKL]PJL!4H_£H[[VT(+*V\[W\[
Gain: 0 to 300%
[FM2]*2 Output form
Pulse monitor(*3) Pulse output: 25 to 32000 p/s at full scale,
Pulse duty: approx. 50%

&RPPRQ6SHFLðFDWLRQV
࠮6\[W\[MYLX\LUJ`)LMVYLZSPWJVTWLUZH[PVU
࠮6\[W\[MYLX\LUJ`(M[LYZSPWJVTWLUZH[PVU
࠮6\[W\[J\YYLU[ ࠮6\[W\[]VS[HNL ࠮6\[W\[[VYX\L
࠮3VHKMHJ[VY ࠮0UW\[WV^LY ࠮PID feedback amount (PV)
Monitor data ࠮Actual speed / Estimated speed ࠮+*SPURI\Z]VS[HNL ࠮<UP]LYZHS(6
࠮4V[VYV\[W\[ ࠮Analog output calibration ࠮70+JVTTHUK:=
࠮70+V\[W\[4= ࠮Position deviation in synchronous operation(The PG option card is required.)
࠮*\Z[VTPaHISLSVNPJV\[W\[[V ࠮0U]LY[LYJVVSPUNÄU[LTWLYH[\YL
࠮7.MLLKIHJR]HS\L;OL7.VW[PVUJHYKPZYLX\PYLK
[CM] Digital Common Common terminals for the digital input signals.

Basic Wiring Diagram


࠮Select multi-frequency (0 to 1 steps) ࠮Select multi-frequency (0 to 3 steps)
࠮Select multi-frequency (0 to 7 steps) ࠮Select multi-frequency (0 to 15 steps)
࠮:LSLJ[(**+,*[PTLZ[LWZ ࠮:LSLJ[(**+,*[PTLZ[LWZ
[X1] Digital input 1
࠮,UHISL^PYLVWLYH[PVU ࠮*VHZ[[VHZ[VW
࠮9LZL[HSHYT ࠮,UHISLL_[LYUHSHSHYT[YPW
࠮9LHK`MVYQVNNPUN ࠮:LSLJ[MYLX\LUJ`JVTTHUK
࠮:LSLJ[TV[VY4 ࠮,UHISL+*IYHRPUN
࠮:LSLJ[[VYX\LSPTP[LYSL]LS ࠮:^P[JO[VJVTTLYJPHSWV^LY/a
࠮:^P[JO[VJVTTLYJPHSWV^LY/a ࠮<70UJYLHZLV\[W\[MYLX\LUJ`
[X2] Digital input 2 ࠮DOWN (Decrease output frequency) ࠮Enable data change with keypad
࠮*HUJLS70+JVU[YVS ࠮Switch normal/inverse operation
࠮0U[LYSVJR ࠮*HUJLS[VYX\LJVU[YVS

Terminal Functions
࠮,UHISLJVTT\UPJH[PVUZSPUR]PH9:VYÄLSKI\ZVW[PVU
࠮<UP]LYZHS+0
࠮,UHISLH\[VZLHYJOMVYPKSPUNTV[VYZWLLKH[Z[HY[PUN
࠮-VYJL[VZ[VW ࠮7YLL_JP[H[PVU,?0;,
[X3] Digital input 3 ࠮9LZL[70+PU[LNYHSHUKKPMMLYLU[PHSJVTWVULU[Z
࠮/VSK70+PU[LNYHSJVTWVULU[ ࠮:LSLJ[SVJHSRL`WHKVWLYH[PVU
࠮(J[P]H[L[OLSPTP[Z^P[JOH[Z[HY[WVPU[ Operation current at ON
࠮:[HY[YLZL[ ࠮Switch to the serial pulse receiving mode Source current: 2.5 to 5 mA
࠮,U[LY[OLYL[\YUTVKL ࠮,UHISLV]LYSVHKZ[VW
Digital inputs

Source current: 9.7 to 16 mA


࠮:LY]VSVJRJVTTHUK ࠮7\SZL[YHPUPUW\[  (terminal [X5])---Pulse train input
࠮7\SZL[YHPUZPNU ࠮)H[[LY`<7:VWLYH[PVU
External Dimensions
[X4] Voltage level: 2 V or below
Digital input 4 ࠮:LSLJ[[VYX\LIPHZ ࠮:LSLJ[[VYX\LIPHZ
࠮/VSK[VYX\LIPHZ ࠮*OLJRIYHRLJVU[YVS Operation current at OFF
࠮3PULZWLLKJVU[YVS ࠮*HUJLSSPULZWLLKJVU[YVS Allowable leakage current:
࠮/VSK[OLSPULSZWLLKJVU[YVSMYLX\LUJ`PU[OLTLTVY` 0.5 mA or less
࠮*V\U[[OLY\U[PTLVMJVTTLYJPHSWV^LYKYP]LUTV[VY Voltage: 22 to 27 VDC
࠮*V\U[[OLY\U[PTLVMJVTTLYJPHSWV^LYKYP]LUTV[VY
[X5] ࠮:LSLJ[KYVVWJVU[YVS ࠮:LSLJ[WHYHTL[LY
Digital input 5 / Pulse train input
࠮:LSLJ[WHYHTL[LY ࠮*HUJLSJ\Z[VTPaHISLSVNPJ
࠮*SLHYHSSJ\Z[VTPaHISLSVNPJ[PTLYZ ࠮*HUJLSH\[VTH[PJKLJLSLYH[PVU
࠮9\UMVY^HYKJVTTHUK ࠮9\UYL]LYZLJVTTHUK
࠮5VM\UJ[PVUHZZPNULK ࠮70+T\S[PZ[LWJVTTHUK
࠮70+T\S[PZ[LWJVTTHUK
Options

[FWD] Run forward command -SINK/SOURCE is switchable by using the internal slide switch.
-These function codes may also switch the logic system between
UVYTHSHUKULNH[P]L[VKLÄULOV^[OLPU]LY[LYSVNPJPU[LYWYL[ZLP[OLY
ON or OFF status of each terminal.
;LYTPUHSB?DJHUILKLÄULKHZHW\SZL[YHPUPUW\[[LYTPUHS^P[O[OL
function codes.
(Using the PG interface interface card makes the pulse train input
[REV] Run reverse command function assigned to the inverter's terminal [X5] invalid.)
Use exclusively with one digital input.
[VR/a6WLU*VSSLJ[VYR/a7\ZOW\SS

21
Terminal Functions
Categoly

Symbol Name Functions Remarks

(1) Power supply for programmable controller output logic circiut (Max DC24V DC100mA.)
[PLC] PLC signal power
(2) Power supply for transistor output logic circuit
[CM] Digital input common Common terminals for the digital input signals.
࠮0U]LY[LYY\UUPUN ࠮0U]LY[LYV\[W\[VU
࠮Frequency (speed) arrival signal ࠮Frequency (speed) arrival signal 2
࠮Frequency (speed) arrival signal 3 ࠮Frequency (speed) detected
࠮-YLX\LUJ`ZWLLKKL[LJ[LK ࠮-YLX\LUJ`ZWLLKKL[LJ[LK
࠮Undervoltage detected (Inverter stopped) ࠮;VYX\LWVSHYP[`KL[LJ[LK
࠮0U]LY[LYV\[W\[SPTP[PUN
࠮(\[VYLZ[HY[PUNHM[LYTVTLU[HY`WV^LYMHPS\YL
࠮+LJLSLYH[PVUHM[LYTVTLU[HY`WV^LYMHPS\YLKL[LJ[LK
࠮4V[VYV]LYSVHKLHYS`^HYUPUN ࠮Inverter output limiting with delay
࠮2L`WHKVWLYH[PVULUHISLK ࠮0U]LY[LYYLHK`[VY\U
[Y1] Transistor output 1 ࠮:LSLJ[(?[LYTPUHSM\UJ[PVU-VY4*VUWYPTHY`ZPKL
࠮:[HNL[YHUZP[PVUZPNUHSMVYWH[[LYUVWLYH[PVU
࠮*`JSLJVTWSL[PVUZPNUHSMVYWH[[LYUVWLYH[PVU
࠮7H[[LYUVWLYH[PVUZ[HNL ࠮7H[[LYUVWLYH[PVUZ[HNL
࠮7H[[LYUVWLYH[PVUZ[HNL ࠮*VVSPUNMHUPUVWLYH[PVU
࠮(\[VYLZL[[PUN ࠮<UP]LYZHS+6
࠮Heat sink overheat early warning ࠮:`UJOYVUPaH[PVUJVTWSL[LK 24 VDC (22 to 27 VDC),
࠮3PML[PTLHSHYT ࠮9LMLYLUJLSVZZKL[LJ[LK Max. 100 mA
࠮6]LYSVHKWYL]LU[PVUJVU[YVS ࠮*\YYLU[KL[LJ[LK This terminal is electrically
Transistor outputs

࠮*\YYLU[KL[LJ[LK ࠮*\YYLU[KL[LJ[LK isolated from terminal [11]s


࠮3V^J\YYLU[KL[LJ[LK ࠮70+HSHYT and [CMY].
࠮<UKLY70+JVU[YVS allowable range: +22 to
࠮4V[VYZ[VWWLKK\L[VZSV^ÅV^YH[L\UKLY70+JVU[YVS +27 VDC, 50 mA max.
࠮3V^V\[W\[[VYX\LKL[LJ[LK ࠮;VYX\LKL[LJ[LK Leakage current 0.1mA or less
࠮;VYX\LKL[LJ[LK ࠮4V[VYZLSLJ[LK
࠮4V[VYZLSLJ[LK ࠮9\UUPUNMVY^HYK
࠮9\UUPUNYL]LYZL ࠮0UYLTV[LVWLYH[PVU
࠮4V[VYV]LYOLH[KL[LJ[LKI`[OLYTPZ[VY
࠮)YHRLZPNUHS
࠮;LYTPUHSB*D^PYLIYLHR ࠮:WLLK]HSPK
࠮:WLLKHNYLLTLU[ ࠮7.LYYVYKL[LJ[LK
࠮3V^=VS[HNLKL[LJ[LK ࠮:[VWWVZP[PVUV]LYYPKLHSHYT
[Y2] Transistor output 2 ࠮*\YYLU[WVZP[PVUJV\U[V]LYÅV^LK ࠮7VZP[PVUPUNJVTWSL[PVUZPNUHS
࠮;PTLYV\[W\[ ࠮4HPU[LUHUJL[PTLY
࠮-YLX\LUJ`HYYP]HSZPNUHS ࠮(SHYTPUKPJH[PVU
࠮(SHYTPUKPJH[PVU ࠮(SHYTPUKPJH[PVU
࠮(SHYTPUKPJH[PVU ࠮3PNO[HSHYT
࠮(SHYTV\[W\[MVYHU`HSHYT ࠮,UHISLJPYJ\P[MHPS\YLKL[LJ[LK
࠮,UHISLPUW\[6-- ࠮)YHRPUN[YHUZPZ[VYIYVRLU
࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS ࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS
࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS ࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS
࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS ࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS
࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS ࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS
࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS  ࠮*\Z[VTPaHISLSVNPJV\[W\[ZPNUHS
This terminal is electrically
[CMY] Transistor output common Common terminal for transistor output signal terminals. isolated from terminal [11]s
and [CM]s.

-This outputs a non-voltage(dry) contact signal (1c) when the inverter Contact rating: 250 VAC, 0.3 A
Relay output

is stopped with the protective function. cosø=0.3


-As a general-purpose relay output, the same functions as terminal 48 VDC, 0.5A
[30A], [30B], [30C] Alarm relay output (for any error)
Y can be assigned. Contact life: 200000 times
-The logic value is switchable between "[30A] and [30C] are excited" (Switching at intervals of
and "non-excited." one second)
*VTWSPHUJL^P[O,50:6 "*H[73!L
Source current at Turn-on :
-Turning off the circuit between terminals [EN1] and [PLC] or
5-10mA
Functional safety

terminals [EN2] and [PLC] stops the inverter's output transistor. (Safe
Threshold voltage between
Torque Off: STO)
[EN1], Enable Input 1 [PLC] - [EN]
-These terminals are exclusively used for the source mode input and
[EN2] Enable Input 2 : 2V (Turn off)
cannot be switched to the sink mode.
: 22 to 27V (Turn on)
-If either one of these input terminals is kept OFF for 50 ms or more,
leakage current
the inverter interprets it as a discrepancy, causing an alarm ECF. This
: 0.5mA or less
alarm state can be cleared only by turning the inverter off and on.
(1) Power supply for programmable controller output logic circiut (Max DC24V DC100mA.)
[PLC] PLC signal power
(2) Power supply for transistor output logic circuit

22
F U J I E L E C T R I C I N V E RT E R S

Terminal Functions

Major Functions
Categoly

Symbol Name Functions Remarks

(1) Used to connect the inverter with the keypad. The inverter
Z\WWSPLZ[OLWV^LY[V[OLRL`WHK[OYV\NO[OLWPUZZWLJPÄLKILSV^
The extension cable for remote operation also uses wires connected
to these pins for supplying the keypad power.
(2) Remove the keypad from the standard RJ-45 connector, and

6WDQGDUG0RGHO6SHFLðFDWLRQV
connect the RS-485 communications cable to control the inverter
RJ-45 connector Standard RJ-45 connector through the PC or PLC (Programmable Logic Controller).
for the keypad (RS-485 communication port 1)
The protocol selection is available from the following.
- Modbus RTU
Communication

- Fuji general-purpose inverter protocol


(Z`UJOYVUV\ZZ[HY[Z[VWZ`Z[LT࠮/HSMK\WSL_
- Max. transmission cable length : 500 m (1640 ft)
- Maximum communication speed : 38.4kbps

A communications port transmits data through the RS-485

&RPPRQ6SHFLðFDWLRQV
multipoint protocol between the inverter and a personal computer or
other equipment such as a PLC.
[DX+],
Standard RJ-45 connector The protocol selection is available from the following.
[DX-],
(RS-485 communication port 2) (*4) - Modbus RTU
[SD]
- Fuji general-purpose inverter protocol
(Z`UJOYVUV\ZZ[HY[Z[VWZ`Z[LT࠮/HSMK\WSL_
- Max. transmission cable length : 500 m (1640 ft)
- Maximum communication speed : 38.4kbps
[CAN+],
[CAN-], Standard RJ-45 connector
*VTTPJPJH[PVU7YVÄSL!*P(*(5VWLU+:HUK+:7

Basic Wiring Diagram


[SHLD] (CAN communication port) (*5)

(*1) In case of applying bais/gain function.


(*2) Only FRN E2 - GB / K has the FM2 output. Not pulse monitor but analog monitor (voltage / current output) is available.
(*3) Exclusive use. Need to swich on the terminal PCB.
(*4) FRN E2 - GA has the RJ-45 connector on the terminal PCB. The CAN bus communication is also available via this connector. But it can not use with
RS-485 communication at the same time.
FRN E2 - GB / K has the bar terminal on the terminal PCB instead of the RJ45 connector. The CAN bus communication is not available in this type.
(*5) In the RJ-45 connector on the terminal PCB. Concurrent use with RS-485 communications is not available.

Terminal Functions
External Dimensions
Options

23
Type
How To Read The Model Number

0022 2
Series name: Destination:
 FRN: FRENIC Series E: Europe
K: Korea
Three phase 400V class:
G : Global
Rating current level of ND specification
: A: 1 CAN terminal, 1 analog current output
[Model: 0002 to 0590]
: B: NONE CAN terminal, 2 analog current output
Three phase 200V class:
Rating current level of HND specification Input power supply:
[Model: 0001 to 0115] 4: Three phase 400V class
Single phase 200V class: 2: Three phase 200V class
Rating current level of HHD specification 7: Single phase 200V class
[Model: 0001 to 0011] S: Standard (basic type)
E: EMC filter built-in type
Applicable tiled
For industrial, High performance, Multiple Functionality
Development code 2: 2

External Dimensions
68(2.68) D [Unit:mm (inch)] 110(4.33) [Unit:mm (inch)]
0.6(0.02) 66.8(2.63) D1 D2 6.85(0.27) 96.3(3.79) 6.85(0.27) D
4.5(0.18)

6(0.24) 56(2.20) 6(0.24) 3(0.12) 2-5.2×5.5(0.20×0.22) D1 D2


ø5.2(0.20) 6(0.24)
6(0.24)
118(4.65)
130(5.12)
118(4.65)
127(5.00)

6(0.24)

5.5(0.22)
9.973(0.39)

5.2(0.20)
4.5(0.18)

Dimension [mm(inch)] Dimension [mm(inch)]


Power supply voltage Inverter type Power supply voltage Inverter type
D D1 D2 D D1 D2
FRN0001E2S-2 85(3.35) 77(3.03) 8(0.31) FRN0002E2S-4 119(4.69) 85(3.35) 34(1.34)
FRN0002E2S-2 85(3.35) 77(3.03) 8(0.31) FRN0004E2S-4 143(5.63) 85(3.35) 58(2.28)
3-phase 200V series 3-phase 400V series
FRN0004E2S-2 100(3.94) 77(3.03) 23(0.91) FRN0006E2S-4 143(5.63) 85(3.35) 58(2.28)
FRN0006E2S-2 132(5.20) 84(3.31) 48(1.89) FRN0007E2S-4 143(5.63) 85(3.35) 58(2.28)
FRN0001E2S-7 85(3.35) 77(3.03) 8(0.31) FRN0010E2S-2 143(5.63) 85(3.35) 58(2.28)
3-phase 200V series
FRN0002E2S-7 85(3.35) 77(3.03) 8(0.31) FRN0012E2S-2 143(5.63) 85(3.35) 58(2.28)
1-phase 200V series
FRN0003E2S-7 107(4.21) 84(3.31) 23(0.91) 1-phase 200V series FRN0008E2S-7 153(6.02) 95(3.74) 58(2.28)
FRN0005E2S-7 152(5.98) 104(4.09) 48(1.89)

24
F U J I E L E C T R I C I N V E RT E R S

External Dimensions

Major Functions
140(5.51) [Unit:mm(inch)] 180(7.09) 158(6.22) [Unit:mm(inch)]
6(0.24) 128(5.04) 6(0.24) D 8(0.32) 164(6.46) 8(0.32) 87.7(3.45)
2×ø5.2(0.2) 5(0.2)
D1 D2

7(0.28)
6(0.24)

6(0.24)
2×ø6(0.24)

6WDQGDUG0RGHO6SHFLðFDWLRQV
118(4.65)
130(5.12)

205(8.07)
220(8.66)
6(0.24)

5.2(0.20)
9.973(0.39)

10(0.39)
8(0.32)
6(0.24)

&RPPRQ6SHFLðFDWLRQV
Basic Wiring Diagram
Dimension [mm(inch)]
Power supply voltage Inverter type Power supply voltage Inverter type
D D1 D2
3-phase 400V series FRN0012E2S-4 143(5.63) 85(3.35) 58(2.28) FRN0022E2S-4
3-phase 400V series
3-phase 200V series FRN0020E2S-2 143(5.63) 85(3.35) 58(2.28) FRN0029E2S-4
1-phase 200V series FRN0011E2S-7 143(5.63) 85(3.35) 58(2.28) FRN0030E2S-2
3-phase 200V series
FRN0040E2S-2

220(8.66) 190(7.48) [Unit:mm(inch)] 250(9.84) [Unit:mm(inch)]

Terminal Functions
226(8.9) 195(7.68)
196(7.72) 90(3.54) 12(0.47) 12(0.47)
12(0.47) 12(0.47) 90(3.54)
11(0.43)

11.2(0.44) 10(0.39)
11(0.43)

2×ø10(0.39)

2×ø10(0.39)
400(15.75)
378(14.88)
260(10.24)
238(9.37)

External Dimensions

10(0.39)
11(0.43)

(41)[(1.61)]

252(9.92)
4×M8
10(0.39)
11(0.43)

10(0.39) 226(8.9)
418.5(16.48)

417(16.42)
357(14.06)
8(0.31)

205(8.07)
19(0.75)

Options

243(9.57)

External Cooling
Panel Cut out

Power supply voltage Inverter type Power supply voltage Inverter type
FRN0037E2S-4 FRN0059E2 -4
3-phase 400V series 3-phase 400V series
FRN0044E2S-4 FRN0072E2 -4
FRN0056E2S-2 FRN0088E2S-2
3-phase 200V series 3-phase 200V series
FRN0069E2S-2 FRN0115E2S-2

25
External Dimensions
[Unit:mm(inch)] [Unit:mm(inch)]
MAX326.2(12.9) MAX361.2(14.3)
320(12.6) MAX261(10.28) 355(13.98) MAX276(10.87)
40(1.57) 240(9.45) 40(1.57) 255(10.04) 40(1.57) 275(10.83) 40(1.57) 270(10.63)
6(0.24) 115(4.53) 140(5.51) 6(0.24) 115(4.53) 155(6.1)
25(0.98)
12(0.47)

25(0.98)
12(0.47)
4(0.16) 2×ø10(0.39) 4(0.16)
2×ø10(0.39)

615(24.21)
565(22.24)
595(23.43)
550(21.65)
500(19.69)
530(20.87)

10(0.39)

25(0.98)
8(0.32)
25(0.98)
8(0.32)

10(0.39) 312(12.28)
9(0.35)

4×M8
288(11.34) 347(13.66)

9(0.35)
4×M8
323(12.72)
512(20.16)
530(20.87)

577(22.72)
595(23.43)
MAX345.2(13.6)
MAX310.2(12.3)
8(0.32) 339(13.35) 8(0.32) 275
8(0.32) 304(11.97) 8(0.32) 240(9.45)
(10.83)

External Cooling External Cooling


Panel Cut out Panel Cut out

Power supply voltage Inverter type Power supply voltage Inverter type
FRN0085E2 -4 3-phase 400V series FRN0139E2 -4
3-phase 400V series
FRN0105E2 -4

[Unit:mm(inch)] [Unit:mm(inch)]
MAX361.2(14.3) MAX361.2(14.2)
355(13.98) MAX276(10.87) 355(13.98) MAX276(10.87)
40(1.57) 275(10.83) 40(1.57) 270(10.63) 40(1.57) 275(10.83) 40(1.57) 270(10.63)
6(0.24) 115(4.53) 155(6.1) 6(0.24) 115(4.53) 155(6.1)
25(0.98)
12(0.47)

25(0.98)
12(0.47)

2×ø10(0.39) 4(0.16) 2×ø10(0.39) 4(0.16)


675(26.57)
625(24.61)
655(25.79)

740(29.13)
690(27.17)
720(28.35)

10(0.39)
25(0.98)
8(0.32)

347(13.66)
9(0.35)

4×M8 10(0.39)
25(0.98)
8(0.32)

323(12.72)
347(13.66)
9(0.35)

4×M8
275
(10.83)
637(25.08)
655(25.79)

702(27.64)
720(28.35)

MAX345.2(13.6)
8(0.32) 339(13.35) 8(0.32) 275
(10.83) MAX345.2(14)
8(0.32) 339(13.35) 8(0.32)
External Cooling
Panel Cut out
External Cooling
Panel Cut out

Power supply voltage Inverter type Power supply voltage Inverter type
3-phase 400V series FRN0168E2 -4 3-phase 400V series FRN0203E2 -4

26
F U J I E L E C T R I C I N V E RT E R S

External Dimensions

Major Functions
[Unit:mm(inch)] [Unit:mm(inch)]
MAX536.4(21.12) MAX536.4(21.12)
530(20.87) MAX321(12.64) 530(20.87) MAX366(14.41)
50 430(16.93) 50(1.97) 360(14.17)
50 430(16.93) 50 315(12.4)

29.3(1.15)
15.5(0.61)
30.1(1.19)
15.5(0.61)

(1.97) 6(0.24) 180(7.09) 180(7.09)


(1.97) (1.97) 6(0.24) 135(5.31) 180(7.09)
2×ø15(0.59) 4(0.16)
2×ø15(0.59) 4(0.16)

6WDQGDUG0RGHO6SHFLðFDWLRQV
678.7(26.72)
740(29.13)

710(27.95)

939.5(36.99)
1,000(39.37)

970(38.19)

&RPPRQ6SHFLðFDWLRQV
12.5(0.49)

15(0.59)
31.2(1.23)
14.5(0.57)

510(20.08)
4×M12
430
(16.93)
15(0.59)

31.2(1.23)
14.5(0.57)

12.5(0.49)
510(20.08)
4×M12
430
(14.17)
685(26.97)
710(27.95)

970(38.19)
945(37.2)
MAX506.4(19.94)
14.7(0.58) 500.6(19.71) 14.7(0.58)

Basic Wiring Diagram


External Cooling MAX506.4(19.94)
14.7(0.58) 500.6(19.71) 14.7(0.58)
Panel Cut out
External Cooling
Panel Cut out

Power supply voltage Inverter type Power supply voltage Inverter type
FRN0240E2 -4 FRN0361E2 -4
3-phase 400V series 3-phase 400V series
FRN0290E2 -4 FRN0415E2 -4

MAX686.4(27.02) [Unit:mm(inch)] [Unit:mm]

Terminal Functions
680(26.77) MAX366(14.41)
50 290(11.42) 290(11.42) 50(1.97) 360(14.17)
68 D
29.3(1.15)
15.5(0.61)

(1.97) 6(0.24) 180(7.09) 180(7.09) 6 56 6 D1 D2


3×ø15(0.59) 4(0.16) 3
ʮ5.2
4.5
127
118

External Dimensions
939.5(36.99)
1,000(39.37)

970(38.19)

4.5

5.2

15(0.59)
31.2(1.23)
14.5(0.57)

660(25.98)
12.5(0.49)

580(22.83)
6×M12 290
(11.42)
Options
970(38.19)
945(37.2)

MAX656.4(25.84)
14.7(0.58) 650.6(25.61) 14.7(0.58) Dimension [mm]
Power supply voltage Inverter type
D D1 D2
FRN0001E2E-2GA 112 104 8
External Cooling FRN0002E2E-2GA 112 104 8
Panel Cut out 3-phase 200V series
FRN0004E2E-2GA 127 104 23
FRN0006E2E-2GA 152 104 48
Power supply voltage Inverter type
FRN0001E2E-7GA 112 104 8
FRN0520E2 -4 1-phase 200V series FRN0002E2E-7GA 112 104 8
3-phase 400V series
FRN0590E2 -4 FRN0003E2E-7GA 127 104 23

27
External Dimensions
[Unit:mm] [Unit:mm]
140
110 D 199
6 128 6
7 96 7 D1 D2 58
6 2-ʮ5.2
6

6
5.5 ʮí
6

5.2

130
118
130
118

10
5.2 5.2
5.5 5.5
10

Dimension [mm]
Power supply voltage Inverter type Power supply voltage Inverter type
D D1 D2
FRN0002E2E-4GA 162 128 34 FRN0006E2E-4GA
3-phase 400V series
FRN0004E2E-4GA 186 128 58 3-phase 400V series FRN0007E2E-4GA
1-phase 200V series FRN0005E2E-7GA 129 95 34 FRN0012E2E-4GA
FRN0010E2E-2GA
3-phase 200V series FRN0012E2E-2GA
FRN0020E2E-2GA
FRN0008E2E-7GA
1-phase 200V series
FRN0011E2E-7GA

[Unit:mm] [Unit:mm]

181.5 208 220 245


12.5

15.75 150 15.75 50 20 180 20 55


2×ø6.5 2×ø8.3
7

2×ø12 2×ø14
8.5
256.5
285

302.5
332

2×6.5 2×8.3

27 25
32 30

Power supply voltage Inverter type Power supply voltage Inverter type

FRN0022E2E-4E FRN0037E2E-4E
3-phase 400V series 3-phase 400V series
FRN0029E2E-4E FRN0044E2E-4E

28
F U J I E L E C T R I C I N V E RT E R S

Keypad

Major Functions
Standard accessory Keypad [Unit:mm (inch)] Multi function Keypad “TP-A1-E2C” (Option) [Unit:mm (inch)]

80(3.1) 17.5 68.5(2.7) 5.8(0.23) 80(3.1)


(0.69)

7(0.28)
(0.57)

(0.54)
8.2 58(2.3)
2×M3 (0.32)

(0.098)

(0.91)
(0.59)
Panal cut part

23
2.5
79.2(3.12)
4.7(0.19)

(0.2) 68.8(2.71) 5.2 16.6 10

6WDQGDUG0RGHO6SHFLðFDWLRQV
111.6(4.4)
(0.2) (0.65) (0.39)

128(5.0)

128(5.0)
A
41.8(1.65)

32.4(1.28)

2×ø4
4.1 (ø0.16)
4.7(0.19)

(0.16) 5.8(0.23) 68.5(2.7)

79.2(3.12)

4.7(0.19)
2.7(0.11)

68.8(2.71) 5.2 Figure of panel cut dimensions (Arrow A)

(0.45)
(0.2)

11.4

8.1(0.32)
2(0.08)

32.4(1.28) *Connect to FRENIC-Ace with LAN cable (straight) with RJ-45 connector.
41.8(1.65)

36.5(1.44)

Panal
cut part

&RPPRQ6SHFLðFDWLRQV
2×M3
To use the Remote Keypad in hand / To install 21 15.4
(0.83) (0.61)
the Remote Keypad on an Enclosure
(Keypad rear cover installed) Figure of panel cut dimensions (Arrow A)

Options
NEMA1 Kit

Basic Wiring Diagram


0[ZWVZZPISL[VJVTWS`^P[OLUJSVZ\YL[`WL5,4(<3;@7,JLY[PÄLK^P[OTV\U[PUN5,4(RP[
Power supply Voltage Inverter type Option type Power supply Voltage Inverter type Option type
FRN0002E2S-4# NEMA1-02E2-4 FRN0001E2S-2#
NEMA1-02E2-27
FRN0004E2S-4# FRN0002E2S-2#
FRN0006E2S-4# NEMA1-12E2-24 FRN0004E2S-2# NEMA1-04E2-2
FRN0007E2S-4# FRN0006E2S-2# NEMA1-06E2-2
FRN0012E2S-4# NEMA1-20E2-247 FRN0010E2S-2#
NEMA1-12E2-24

Terminal Functions
FRN0022E2S-4# FRN0012E2S-2#
NEMA1-40E2-24
FRN0029E2S-4# Three-phase 200V FRN0020E2S-2# NEMA1-20E2-247
FRN0037E2S-4# FRN0030E2S-2#
NEMA1-69E2-24 NEMA1-40E2-24
FRN0044E2S-4# FRN0040E2S-2#
FRN0059E2 -4# FRN0056E2S-2#
NEMA1-72E2-4 NEMA1-69E2-24
FRN0072E2 -4# FRN0069E2S-2#
Three-phase 400V
FRN0085E2 -4# FRN0088E2 -2#
NEMA1-105E2-4 NEMA1-72E2-4
FRN0105E2 -4# FRN0115E2 -2#

External Dimensions
FRN0139E2 -4# FRN0001E2S-7#
NEMA1-02E2-27
FRN0168E2 -4# NEMA1-203E2-4 FRN0002E2S-7#
FRN0203E2 -4# FRN0003E2S-7# NEMA1-03E2-7
Single-phase 400V
FRN0240E2 -4# FRN0005E2S-7# NEMA1-05E2-7
NEMA1-110G1-4
FRN0290E2 -4# FRN0008E2S-7# NEMA1-08E2-7
FRN0361E2 -4# FRN0011E2S-7# NEMA1-20E2-247
NEMA1-160G1-4
FRN0415E2 -4#
FRN0520E2 -4#
NEMA1-590E2-4
FRN0590E2 -4#
#: Destination GA: for global w/ terminal block, GB: for global w/o terminal block, E: for Europe.
!:!:[HUKHYKIHZPJ[`WL,!,4*ÄS[LYI\PS[PU[`WL [V 
Options

29
Options
Adapter
Type Option Functions
ADP1:The adapter is mounted on the front side of the inverter. The adapter is used from 0002 to
OPC-E2-ADP1
0044 of 400V, 0001 to 0069 of 200V for FRENIC-Ace.
ADP2:The adapter is mounted inside of the inverter. The adapter is used from 0059 to 0072 of
OPC-E2-ADP2 Mounting adapter for option card
400V , 0069 to 0115 of 200V for FRENIC-Ace.
ADP3:The adapter is mounted inside of the inverter. The adapter is used in more than 0085 of
OPC-E2-ADP3
400V for FRENIC-Ace.

Communication, I/O Parts


Type Option Functions

This card enables operation instruction and frequency No. of connection nodes: max. 64 units (including the master unit)
MAC ID: 0~63
OPC-DEV DeviceNet communication card command to be set from the DeviceNet master,
Insulation: 500V DC (photocoupler insulation)
allowing operation conditions to be monitored and all Communications rate: 500kbps/250kbps/125kbps
the function codes to be changed and checked. Network consumed power: max. 80mA, 24V DC

This card enables operation instruction and frequency


No. of connection units: 42 units
command to be set from the CC-Link master, allowing
OPC-CCL CC-Link communication card Communications method: CC-Link Ver1.10 and Ver2.0
operation conditions to be monitored and all the Communications rate: 156kbps~10Mbps
function codes to be changed and checked.

This card enables operation instruction and frequency


Communications rate: 9.6kbps~12Mbps
command to be set from the PROFIBUS-DP master,
OPC-PDP3 PROFIBUS-DP communication card Transmission distance: ~1,200m(3900ft)
allowing operation conditions to be monitored and all Connection connector: 2×6-pole terminal block
the function codes to be changed and checked.

This card enables operation instruction and frequency No. of connection nodes: 127 units
command to be set from the CANopen master (such as Communications rate: 20k, 50k, 125k, 250k, 500k,
OPC-COP2 CANopen communication card
PC and PLC), allowing all the function codes to be set 800k, 1Mbps
and checked. Transmission distance: ~2,500m(8200ft)

OPC-PRT Ethernet comunication card This interface card allows to connect FRENIC-Ace to a Ethernet network.
Supported protocols currently include:PROFINET IO, EtherNet/IP
DI: The frequency set-point can be given by 8,12 bits and BCD code(0 to 99.9/0 to 999) and extended
OPC- DIO Digital I/O interface card 13 digital inputs are available mounting this card in the inverter. DO: The monitoring with 8bit binary
code and the digital outputs (extended 8 point) are available.

OPC-AIO Analog I/O interface card The Analog I/O interface card enables the FRENIC-Ace series of the inverter to input analog set-points to the
inverter and output analog monitors from the inverter.
* Parts adapter is necessary on the occasion of setting.

Parts Using The Control Terminal Stand


Type Option Functions
The RS-485 communication card provides two ports exclusively designed for use with the
OPC-E2-RS RS-485 communication card
FRENIC-Ace series of the inverters.
Speed control, position control and synchronous drive are available mounting this card in the inverter.
OPC-E2-PG PG interface (5V) card ࠮6WLUJVSSLJ[VYW\SS\WYLZPZ[VY!£!R/a
࠮*VTWSLTLU[HY`[V[LTWVSLW\ZOW\SS!R/a
࠮=VS[HNLV\[W\[!=
Speed control, position control and synchronous drive are available mounting this card in the inverter.
࠮6WLUJVSSLJ[VYW\SS\WYLZPZ[VY!£!R/a
OPC-E2-PG3 PG interface (12/15V) card
࠮*VTWSLTLU[HY`[V[LTWVSLW\ZOW\SS!R/a
࠮=VS[HNLV\[W\[!==

Keypad
Type Option Functions
TP-A1-E2C Multi-functional keypad LCD(Liquid Crystal Display) with a back light.
TP-E1U Keypad with USB The keypad for the USB connection with the PC.

30
F U J I E L E C T R I C I N V E RT E R S

DC Reactor (DCR - )

Major Functions
Fig. A Fig. B Fig. C
Terminal block
(for screw J) 2-terminal holes
(for screw J)

6WDQGDUG0RGHO6SHFLðFDWLRQV
4-mounting holes
4-mounting holes 2-terminal
(for screw G)
(for screw G) 4-mounting holes (for screw G) holes
(for screw J)

Nominal Inverter Type Dimension [mm] Approx


Reactor
Voltage applied
motor ND /+ /5+ //+ Fig Weight
Type W W1 D D1 D2 / / G J
[kW] :WLJPÄJH[PVU :WLJPÄJH[PVU :WLJPÄJH[PVU :WLJPÄJH[PVU [kg]
0.4 — — — FRN0002E2 -4# DCR4-0.4 15 1

&RPPRQ6SHFLðFDWLRQV
0.75 FRN0002E2 -4# FRN0002E2 -4# FRN0002E2 -4# FRN0004E2 -4# DCR4-0.75 1.4
66 56 90 72 94 M4(5.2×8)
1.1 — FRN0004E2 -4# FRN0004E2 -4# — DCR4-1.5 20
1.6
1.5 FRN0004E2 -4# — — FRN0006E2 -4# DCR4-1.5
M4
2.2 FRN0006E2 -4# FRN0006E2 -4# FRN0006E2 -4# FRN0007E2 -4# DCR4-2.2 15 2
3 FRN0007E2 -4# FRN0007E2 -4# FRN0007E2 -4# — DCR4-3.7
86 71 110 M5(6×9)
3.7 — — — FRN0012E2 -4# DCR4-3.7 A 20 — 2.6
100 80
5.5 FRN0012E2 -4# FRN0012E2 -4# FRN0012E2 -4# FRN0022E2 -4# DCR4-5.5
7.5 — FRN0022E2 -4# FRN0022E2 -4# FRN0029E2 -4# DCR4-7.5 4.2
111 95 24 130
11 FRN0022E2 -4# FRN0029E2 -4# FRN0029E2 -4# FRN0037E2 -4# DCR4-11 M5 4.3

Basic Wiring Diagram


15 FRN0029E2 -4# FRN0037E2 -4# FRN0037E2 -4# FRN0044E2 -4# DCR4-15 15 168 M6(7×11) 5.9
18.5 FRN0037E2 -4# FRN0044E2 -4# FRN0044E2 -4# FRN0059E2 -4# DCR4-18.5 146 124 120 96
25 171 M6 7.2
22 FRN0044E2 -4# FRN0059E2 -4# FRN0059E2 -4# FRN0072E2 -4# DCR4-22A
30 FRN0059E2 -4# FRN0072E2 -4# FRN0072E2 -4# FRN0085E2 -4# DCR4-30B B 152 157 115 100 130 190
90 M6(ø8) 13
3-phase
37 FRN0072E2 -4# FRN0085E2 -4# FRN0085E2 -4# FRN0105E2 -4# DCR4-37C C 210 101 81 105 125 —
185 M6(7×13) 7.4
400V
DCR4-45B B 171 165 125 110 150 210
110 M6(ø8) M8 18
45 FRN0085E2 -4# FRN0105E2 -4# FRN0105E2 -4# FRN0139E2 -4#
DCR4-45C C 210 106 86 120 125 —
185 M6(7×13) 8.4
DCR4-55B B 171 170 130 110 150 210
110 M6(ø8) 20
55 FRN0105E2 -4# FRN0139E2 -4# FRN0139E2 -4# FRN0168E2 -4#
DCR4-55C 96 76 120 11
M10

Terminal Functions
75 FRN0139E2 -4# FRN0168E2 -4# FRN0168E2 -4# FRN0203E2 -4# DCR4-75C 255 225 106 86 125 145 M6(7×13) 13
90 FRN0168E2 -4# FRN0203E2 -4# FRN0203E2 -4# FRN0240E2 -4# DCR4-90C 96 140 15
116
110 FRN0203E2 -4# FRN0240E2 -4# FRN0240E2 -4# FRN0290E2 -4# DCR4-110C 90 175 155 19
300 265 M8(10×18)
132 FRN0240E2 -4# FRN0290E2 -4# FRN0290E2 -4# FRN0361E2 -4# DCR4-132C 126 100 160 22
180
160 FRN0290E2 -4# FRN0361E2 -4# FRN0361E2 -4# FRN0415E2 -4# DCR4-160C C 131 103 M12 26
200 FRN0361E2 -4# FRN0415E2 -4# FRN0415E2 -4# FRN0520E2 -4# DCR4-200C 141 113 185 30
220 FRN0415E2 -4# FRN0520E2 -4# FRN0520E2 -4# FRN0590E2 -4# DCR4-220C 350 310 146 118 200 190 33
M10(12×22)
250 — FRN0590E2 -4# — — DCR4-250C 35
161 133 210
280 FRN0520E2 -4# — FRN0590E2 -4# — DCR4-280C 37
M16
External Dimensions
315 FRN0590E2 -4# — — — DCR4-315C 400 345 146 118 200 225 40
0.1 — — — FRN0001E2 -2# DCR2-0.2
5 0.8
0.2 — — FRN0001E2 -2# FRN0002E2 -2# DCR2-0.2

0.4 — — FRN0002E2 -2# FRN0004E2 -2# DCR2-0.4 15 1
66 56 90 72 94 M4(5.2×8)
0.75 — — FRN0004E2 -2# FRN0006E2 -2# DCR2-0.75 1.4
1.1 — — FRN0006E2 -2# — DCR2-1.5 20 M4
1.6
1.5 — — — FRN0010E2 -2# DCR2-1.5
2.2 — — FRN0010E2 -2# FRN0012E2 -2# DCR2-2.2 10 1.8
3-phase 3 — — FRN0012E2 -2# — DCR2-3.7 86 71 110 M5(6×9)
200V 2.6
3.7 — — — FRN0020E2 -2# DCR2-3.7 20
100 80
5.5 — — FRN0020E2 -2# FRN0030E2S-2# DCR2-5.5 3.6
130 M5
Options

7.5 — — FRN0030E2S-2# FRN0040E2S-2# DCR2-7.5 111 95 23 3.8


A
11 — — FRN0040E2S-2# FRN0056E2S-2# DCR2-11 24 137 M6 4.3
M6(7×11)
15 — — FRN0056E2S-2# FRN0069E2S-2# DCR2-15 15 5.9
18.5 — — FRN0069E2S-2# FRN0088E2S-2# DCR2-18.5 146 124 120 96 180 M8 7.4
25
22 — — FRN0088E2S-2# FRN0115E2S-2# DCR2-22A 7.5
30 — — FRN0115E2S-2# — DCR2-30B 152 90 156 116 115 130 190 M6(ø8) M10 12
0.1 — — — FRN0001E2 -7# DCR2-0.2 5
0.8
0.2 — — — FRN0002E2 -7# DCR2-0.4 15
single- 66 56 90 72 94 M4(5.2×8)
0.4 — — — FRN0003E2 -7# DCR2-0.75 1.4
phase — M4
200V 0.75 — — — FRN0005E2 -7# DCR2-1.5 1.6
20
1.5 — — — FRN0008E2 -7# DCR2-3.7
86 71 100 80 110 M5(6×9) 2.6
2.2 — — — FRN0011E2 -7# DCR2-3.7
!:!:[HUKHYKIHZPJ[`WL,!,4*ÄS[LYI\PS[PU[`WL
# : Destination GA: for global w/ terminal block, GB: for global w/o terminal block, E: for Europe, K: for Korea.
31
NOTES
s Reducing noise
When running general-purpose motors Environmental conditions Use of a filter and shielded wires are typical
s Driving a 400V general-purpose motor s Installation location measures against noise to ensure that EMC
When driving a 400V general-purpose motor with Use the inverter in a location with an ambient Directives are met.
an inverter using extremely long cables, damage to temperature range of -10 to 50˚C. s Measures against surge currents
the insulation of the motor may occur. Use an output The inverter and braking resistor surfaces become If an overvoltage trip occurs while the inverter is
circuit filter (OFL) if necessary after checking with hot under certain operating conditions. Install the stopped or operated under a light load, it is
the motor manufacturer. Fuji's motors do not require inverter on nonflammable material such as metal. assumed that the surge current is generated by
the use of output circuit filters because of their Ensure that the installation location meets the open/close of the phase-advancing capacitor in the
reinforced insulation. environmental conditions specified in "Environment" power system.
in inverter specifications. We recommend connecting a DC REACTOR to the
s Torque characteristics and temperature rise
When the inverter is used to run a general-purpose inverter.
Combination with peripheral devices
motor, the temperature of the motor becomes s Megger test
higher than when it is operated using a commercial s Installing a molded case circuit When checking the insulation resistance of the
power supply. In the low-speed range, the cooling breaker (MCCB) inverter, use a 500V megger and follow the
effect will be weakened, so decrease the output Install a recommended molded case circuit breaker instructions contained in the Instruction Manual.
torque of the motor. If constant torque is required in (MCCB) or an earth leakage circuit breaker (ELCB)
the low-speed range, use a Fuji inverter motor or a in the primary circuit of each inverter to protect the Wiring
motor equipped with an externally powered wiring. Ensure that the circuit breaker capacity is
ventilating fan. equivalent to or lower than the recommended
s Wiring distance of control circuit
When performing remote operation, use the twisted
s Vibration capacity.
shield wire and limit the distance between the
When the motor is mounted to a machine, s Installing a magnetic contactor (MC) inverter and the control box to 20m.
resonance may be caused by the natural in the output (secondary) circuit
frequencies, including that of the machine. If a magnetic contactor (MC) is mounted in the s Wiring length between inverter and motor
Operation of a 2-pole motor at 60Hz or more may inverter's secondary circuit for switching the motor If long wiring is used between the inverter and the motor, the
cause abnormal vibration. to commercial power or for any other purpose, inverter will overheat or trip as a result of overcurrent (high-
* Study use of tier coupling or dampening rubber. ensure that both the inverter and the motor are fully frequency current flowing into the stray capacitance) in the
* It is also recommended to use the inverter jump stopped before you turn the MC on or off. Remove wires connected to the phases. Ensure that the wiring is
frequency control to avoid resonance points. the surge killer integrated with the MC. shorter than 50m. If this length must be exceeded, lower the
carrier frequency or mount an output circuit filter (OFL).
s Noise s Installing a magnetic contactor (MC) When wiring is longer than 50m, and sensorless vector
When an inverter is used with a general-purpose in the input (primary) circuit control or vector control with speed sensor is selected,
motor, the motor noise level is higher than that with Do not turn the magnetic contactor (MC) in the execute off-line tuning.
a commercial power supply. To reduce noise, raise primary circuit on or off more than once an hour as
carrier frequency of the inverter. High-speed an inverter fault may result. If frequent starts or s Wiring size
operation at 60Hz or more can also result in more stops are required during motor operation, use Select cables with a sufficient capacity by referring
noise. FWD/REV signals. to the current value or recommended wire size.

s Protecting the motor s Wiring type


When running special motors Do not use multicore cables that are normally used
The electronic thermal facility of the inverter can
for connecting several inverters and motors.
s Explosion-proof motors protect the general-purpose motor. The operation
When driving an explosion-proof motor with an level and the motor type (general-purpose motor, s Grounding
inverter, use a combination of a motor and an inverter motor) should be set. For high-speed Securely ground the inverter using the grounding
inverter that has been approved in advance. motors or water-cooled motors, set a small value for terminal.
the thermal time constant to protect the motor.
s Brake motors Selecting inverter capacity
If you connect the motor thermal relay to the motor
For motors equipped with parallel-connected
with a long cable, a high-frequency current may flow
brakes, their braking power must be supplied from s Driving general-purpose motor
into the wiring stray capacitance. This may cause
the primary circuit (commercial power supply). If the Select an inverter according to the applicable motor
the relay to trip at a current lower than the set value
brake power is connected to the inverter power ratings listed in the standard specifications table for
for the thermal relay. If this happens, lower the
output circuit (secondary circuit) by mistake, the inverter. When high starting torque is required or
carrier frequency or use the output circuit filter
problems may occur. quick acceleration or deceleration is required, select
(OFL).
Do not use inverters for driving motors equipped an inverter with a capacity one size greater than the
with series-connected brakes. s Discontinuance of power-factor correcting capacitor standard.
Do not mount power factor correcting capacitors in
s Geared motors s Driving special motors
the inverter (primary) circuit. (Use the DC
If the power transmission mechanism uses an oil- Select an inverter that meets the following condition:
REACTOR to improve the inverter power factor.) Do
lubricated gearbox or speed changer/reducer, then Inverter rated current > Motor rated current.
not use power factor correcting capacitors in the
continuous motor operation at low speed may
inverter output circuit (secondary). An overcurrent
cause poor lubrication. Avoid such operation.
trip will occur, disabling motor operation. Transportation and storage
s Single-phase motors
s Discontinuance of surge killer When transporting or storing inverters, follow the
Single-phase motors are not suitable for inverter-
Do not mount surge killers in the inverter output procedures and select locations that meet the
driven variable speed operation. Use three-phase
(secondary) circuit. environmental conditions that agree with the
motors.
inverter specifications.

Gate City Ohsaki, East Tower, 11-2,


Osaki 1-chome, Shinagawa-ku,
Tokyo 141-0032, Japan
Phone: +81-3-5435-7190 Fax: +81-3-5435-7475
URL: https://www.fujielectric.com/

Printed in Japan 2018-2(B18g/B14) T 00 FOLS

S-ar putea să vă placă și