Documente Academic
Documente Profesional
Documente Cultură
Name of link : NOFN backend against lossy fiber in Jhajjar block for
BHQ JJR,Gudha,Kheri Khummar Talav GPs
Route Length : 4380 m
Optical length : 4690 m
No. Of fibers : 24F
Make of Cable : STERLITE
Type of Cable : 24F
Refractive Index : 1.46700 at 1310nm, 1.46800 at 1550nm
Wave length of Optical source : 1310 nm, 1550 nm
Year of manufacture : 2017
No. Of Splice : 5 (Including terminations)
No. Of Terminations : 0
26 RI: 21
No. Of Route Indicators : JI: 5
Probable date of
commencement
of testing : 12/7/2017
JTO/SDE AT
AT test schedule & testing procedure for OFC
Name of Link: NOFN backend lossy route NTR JC To Kheri Khummar
Name of Section: NTR JC To Kheri Khummar
Optical length of section(km) 3.815 Date of testing 12/7/2017
Transmit power(dbm) -2.5 Type of cable 24F SMF
AT 1310 nm
Fiber test report
Optical window 1310
JTO/SDE AT
AT test schedule & testing procedure for OFC
Name of Link: NOFN backend lossy route BHQ JJR Joint To Rohtak Road Joint
Name of Section: BHQ JJR Joint To Rohtak Road Joint
Optical length of section(km): 0.875 Date of testing 12/7/2017
Transmit power(dbm) -2.5 Type of cable 24F SMF
AT 1550 nm
Fiber test report
Optical window 1550
JTO/SDE AT
AT test schedule & testing procedure for OFC
Name of Link: NOFN backend lossy route BHQ JJR Joint To Rohtak Road Joint
Name of Section: BHQ JJR Joint To Rohtak Road Joint
Optical length of section(km): 0.875 Date of testing 12/7/2017
Transmit power(dbm) -2.5 Type of cable 24F SMF
AT 1310 nm
Fiber test report
Optical window 1310
Specification:
Rec power better than
excluding FDF Actual 0.38db/km
loss but including No of loss of cable Loss at
Fiber No. splice loss Total loss joints joints loss (db/Km) 1310 nm
1 -2.85 -0.35 2 -0.04 -0.31 -0.35 OK
2 -2.81 -0.31 2 -0.03 -0.28 -0.32 OK
3 -2.8 -0.3 2 -0.03 -0.27 -0.31 OK
4 -2.82 -0.32 2 -0.04 -0.28 -0.32 OK
5 -2.81 -0.31 2 -0.03 -0.28 -0.32 OK
6 -2.84 -0.34 2 -0.05 -0.29 -0.33 OK
7 -2.83 -0.33 2 -0.04 -0.29 -0.33 OK
8 -2.82 -0.32 2 -0.03 -0.29 -0.33 OK
9 -2.85 -0.35 2 -0.03 -0.32 -0.37 OK
10 -2.85 -0.35 2 -0.02 -0.33 -0.37 OK
11 -2.84 -0.34 2 -0.04 -0.3 -0.34 OK
12 -2.84 -0.34 2 -0.04 -0.3 -0.34 OK
13 -2.81 -0.31 2 -0.02 -0.29 -0.33 OK
14 -2.81 -0.31 2 -0.03 -0.28 -0.32 OK
15 -2.81 -0.31 2 -0.03 -0.28 -0.32 OK
16 -2.84 -0.34 2 -0.03 -0.31 -0.35 OK
17 -2.86 -0.36 2 -0.05 -0.31 -0.35 OK
18 -2.86 -0.36 2 -0.04 -0.32 -0.37 OK
19 -2.84 -0.34 2 -0.03 -0.31 -0.35 OK
20 -2.8 -0.3 2 -0.03 -0.27 -0.31 OK
21 -2.81 -0.31 2 -0.04 -0.27 -0.31 OK
22 -2.82 -0.32 2 -0.04 -0.28 -0.32 OK
23 -2.84 -0.34 2 -0.04 -0.3 -0.34 OK
24 -2.81 -0.31 2 -0.03 -0.28 -0.32 OK
JTO/SDE AT
Format of Depth A/T of OFC
Fiber No Loss in db
1 -0.01
2 -0.02
3 -0.02
4 -0.01
5 -0.02
6 -0.01
7 -0.02
8 -0.01
9 -0.02
10 -0.01
11 -0.02
12 -0.01
13 -0.02
14 -0.02
15 -0.01
16 -0.01
17 -0.01
18 -0.02
19 -0.01
20 -0.01
21 -0.02
22 -0.01
23 -0.02
24 -0.01
SDE/JTO (AT)
Splice Loss Sheet For NTR Joint Near Petrol Pump
Fiber No Loss in db
1 -0.02
2 -0.01
3 -0.02
4 -0.02
5 -0.03
6 -0.01
7 -0.02
8 -0.01
9 -0.02
10 -0.03
11 -0.03
12 -0.02
13 -0.02
14 -0.02
15 -0.03
16 -0.03
17 -0.02
18 -0.04
19 -0.03
20 -0.02
21 -0.02
22 -0.02
23 -0.01
24 -0.02
SDE/JTO (AT)
Splice Loss Sheet For Joint at Kheri Khummar
Fiber No Loss in db
1 -0.02
2 -0.01
3 -0.02
4 -0.02
5 -0.02
6 -0.02
7 -0.02
8 -0.04
9 -0.01
10 -0.02
11 -0.02
12 -0.02
13 -0.01
14 -0.01
15 -0.01
16 -0.03
17 -0.02
18 -0.01
19 -0.02
20 -0.02
21 -0.01
22 -0.03
23 -0.02
24 -0.02
SDE/JTO (AT)
Splice Loss Sheet For Joint Near BHQ JJR
Fiber No Loss in db
1 -0.02
2 -0.01
3 -0.02
4 -0.03
5 -0.01
6 -0.03
7 -0.01
8 -0.02
9 -0.02
10 -0.01
11 -0.02
12 -0.03
13 -0.01
14 -0.02
15 -0.02
16 -0.01
17 -0.02
18 -0.02
19 -0.01
20 -0.02
21 -0.02
22 -0.02
23 -0.01
24 -0.02
SDE/JTO (AT)
Splice Loss Sheet For Joint At Rohtak Road
Fiber No Loss in db
1 -0.02
2 -0.02
3 -0.01
4 -0.01
5 -0.02
6 -0.02
7 -0.03
8 -0.01
9 -0.01
10 -0.01
11 -0.02
12 -0.01
13 -0.01
14 -0.01
15 -0.01
16 -0.02
17 -0.03
18 -0.02
19 -0.02
20 -0.01
21 -0.02
22 -0.02
23 -0.03
24 -0.01
SDE/JTO (AT)