Documente Academic
Documente Profesional
Documente Cultură
TABLE OF CONTENTS
0 2005 - 08 - 30 T. Anttonen
Muut. Pvm Laatinut Pvm Tarkastanut Pvm Hyväksynyt
Rev. Date Prepared by Date Reviewed by Date Approved by
KLY-1 1997-05 P:\582-RAPP-PB3\int\Kayttoonotto\käyttöohje\Operation and Maintenance Manuals\Folder
2\10.1 Design data.doc
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10. APPENDICES
10.1.1 General
Relative Humidity % 80
Cooling Water
Design temperature °C 32
Pressure at 0-level bar(a) 3.0
Filtration µm 50
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
Process Water
Design temperature °C 32
Pressure at 0-level bar(g) 4.0
Instrument Air
Air pressure bar(g) 5 ... 7
Mill air
Operating pressure bar(g) 5 ... 7
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.2 Boiler
The boiler is designed for bituminous coal and bark firing and it is
based on circulating fluidized bed (CFB) technology.
10.1.2.1 Steam
10.1.2.3 Fuels
The design of the boiler is based on the following design fuel data
only. The availability guarantee and mechanical warranty are valid
for operation within the given range. Performance guarantees are
given with design fuels. Small variation from design fuels will be
corrected with correction curves to correspond the design fuels.
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.2.3.1 Coal
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
Ultimate analysis for coal range and analysis used for performance
calculations (air dry basis)’’
Range Design
Carbon C wt-% 55 – 65 59,7
Hydrogen H wt-% 4,0 – 6,0 4,7
Oxygen O wt-% 11,0 – 13,5 11,58
Nitrogen N wt-% 0,45 – 0,65 0,52
Sulphur S wt-% 0,6 – 2,0 1,50
Ash wt-% 8,0 – 15,0 11,5
Moisture 10,5
Total 100,0
**
Moisture of air dried sample for design is 10,5 %
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.2.3.2 Bark
Moisture content
• design for performance wt-% 50
• range wt-% 40 – 60
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
Moisture content
• design for performance wt-% 70
• range wt-% 60 – 80
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.3 Water
pH-25 6,5 – 8
Hardness (Ca++ + Mg++), max ppb 3
Iron, max mg/kg 0,02
Copper, max mg/kg 0,003
Silica, max mg/kg 0,02
Na+K, max mg/kg 0,01
Oil mg/kg 0
Cation conductivity at 25 °C, max µS/cm 0,2
Temperature °C 32
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
pH – 25 8,8 – 9,2
Oxygen, max mg/kg 0,01
Hardness, max ppb 3
Total Iron, max mg/kg 0,02
Copper, max mg/kg 0,003
Silica, max mg/kg 0,02
Na+K, max mg/kg 0,01
Oil + sludge + foaming substances mg/kg 0,0
Cation conductivity at 25 °C, max µmS/cm 0,2
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.4.1 Sand
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.
10.1.4.2 Limestone
This document is the exclusive intellectual property of Kvaerner Power Oy and is furnished for the sole purpose of operating and maintaining of the specific project, and re-use of the document for any other project or
purpose is prohibited. The document or the information shall not be reproduced or copied, or disclosed to a third party without prior written consent of Kvaerner Power Oy.